Bids Are Invited For Pyranometer - Range0 To 2000 W / M2driftup To+, -2% Per Yearvoltage24 Dc For Signal ConditionertransducerThermo Pileoperating Temperature-40 To +150 Fsensitivity:10Μv / Wm²impedence: 33???To45range: 0 To 2000M / M²viewing Field: 2P-Gujarat

Directorate Of Employment And Training-DGET has published Bids Are Invited For Pyranometer - Range0 To 2000 W / M2driftup To+, -2% Per Yearvoltage24 Dc For Signal ConditionertransducerThermo Pileoperating Temperature-40 To +150 Fsensitivity:10Μv / Wm²impedence: 33???To45range: 0 To 2000M / M²viewing Field: 2P. Submission Date for this Tender is 27-09-2021. Lifting Equipment Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

29254365
Bids Are Invited For Pyranometer - Range0 To 2000 W / M2driftup To+, -2% Per Yearvoltage24 Dc For Signal ConditionertransducerThermo Pileoperating Temperature-40 To +150 Fsensitivity:10Μv / Wm²impedence: 33???To45range: 0 To 2000M / M²viewing Field: 2P
Open Tender
Indian
Gujarat
27-09-2021

Tender Details

Bids Are Invited For Pyranometer - Range0 To 2000 W / M2driftup To+, -2% Per Yearvoltage24 Dc For Signal ConditionertransducerThermo Pileoperating Temperature-40 To +150 Fsensitivity:10Μv / Wm²impedence: 33???To45range: 0 To 2000M / M²viewing Field: 2P Srspectral Field: 305 Nm÷2800 Nm W / M² ( 50% ) Operating Temperature: - 40 To 80°Cweight:45 Gramsresponse Time<30Seczero Offset:A ) Response To Thermal Radiation: 25W / M²b ) Response To Emperature Change 5K / H:<1±6Lw / M²3a ) Non Stability Over One Year:<1%±2.5L%3B ) Non Linearity:<1±2L%3C ) Cosineresponse:<1±22Lw / M²3d ) Special Selectivity: <1±7L%3E ) Rresponse With Regard Temperature:<8%3F ) Tilt Response:<1%±4L% , Pyrheliometer - Range0 To 2000 W / M2driftup To+, -2% Per Yearvoltage24 Dc For Signal ConditionertransducerThermo Pileoperating Temperature-40 To +150 Fsensitivity:10Μv / Wm²impedence: 33???To45range: 0 To 2000M / M²viewing Field: 2P Srspectral Field: 305 Nm÷2800 Nm W / M² ( 50% ) Operating Temperature: - 40 To 80°Cweight:45 Gramsresponse Time<30Seczero Offset:A ) Response To Thermal Radiation: 25W / M²b ) Response To Emperature Change 5K / H:<1±6Lw / M²3a ) Non Stability Over One Year:<1%±2.5L%3B ) Non Linearity:<1±2L%3C ) Cosineresponse:<1±22Lw / M²3d ) Special Selectivity: <1±7L%3E ) Rresponse With Regard Temperature:<8%3F ) Tilt Response:<1%±4L% , Sun Shine Recorder - 0.5W, 0-4000 W / M2 , Cut Model Of Lead Acid Battery - 12V, 100 Ah , Solar Dc Pump 1 Hp - Capacity1hppump Typebldc 1 Hpmotor Typedcvoltage75 V Dcpressurehigh Pressurepump Head0-90 Meter Head Duty Point And 120 Meter Shutoffsuction / Discharge5000 Lpdmaterialss Pump With Dc Controller Drinking Water Supplycurrent10Adimension Of Inlet And Outlet0.5 Inch Inlet And 0.5 Inch Outlet , Solar Cell Based Sunlight Radiationmeter - For Solar Power Measurement Up To2000 W / Square Meter , Cut Models Of Photo Voltaic Cell Assembly - 250W, 12V And 0.5W Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 1.50 Lakhs /-

BOQ Items

Sl. No. Item TitleItem Description
1PYRANOMETERRange0 to 2000 W/m2 Driftup to+,-2% per year Voltage 24 DC for signal conditioner Transducer Thermo pile Operating Temperature -40 to +150 F Sensitivity:10µv/wm² Impedence: 33???to45 Range: 0 to 2000m/m² Viewing Field: 2p sr Spectral field: 305 nm÷2800 nm w/m²(50%) Operating Temperature: - 40 to 80°C Weight:45 grams Response time<30sec Zero Offset: a)response to thermal radiation: 25w/m² b)response to emperature change 5k/h:<1±6lw/m² 3a)Non stability over one year:<1%±2.5l% 3b)Non linearity:<1±2l% 3c)Cosineresponse:<1±22lw/m² 3d)Special selectivity: <1±7l% 3e)rResponse with regard Temperature:<8% 3f)Tilt response:<1%±4l%
2PYRHELIOMETERRange0 to 2000 W/m2 Driftup to+,-2% per year Voltage 24 DC for signal conditioner Transducer Thermo pile Operating Temperature -40 to +150 F Sensitivity:10µv/wm² Impedence: 33???to45 Range: 0 to 2000m/m² Viewing Field: 2p sr Spectral field: 305 nm÷2800 nm w/m²(50%) Operating Temperature: - 40 to 80°C Weight:45 grams Response time<30sec Zero Offset: a)response to thermal radiation: 25w/m² b)response to emperature change 5k/h:<1±6lw/m² 3a)Non stability over one year:<1%±2.5l% 3b)Non linearity:<1±2l% 3c)Cosineresponse:<1±22lw/m² 3d)Special selectivity: <1±7l% 3e)rResponse with regard Temperature:<8% 3f)Tilt response:<1%±4l%
3SUN SHINE RECORDER0.5W,0-4000 W/M2
4CUT MODEL OF LEAD ACID BATTERY12V, 100 Ah
5SOLAR DC PUMP 1 HPCapacity1HP Pump TypeBLDC 1 HP Motor TypeDC Voltage75 V DC PressureHigh Pressure Pump Head0-90 METER HEAD DUTY POINT AND 120 METER SHUTOFF Suction/Discharge5000 LPD MaterialSS PUMP WITH DC CONTROLLER Drinking water supply Current 10A Dimension Of Inlet And Outlet0.5 inch inlet and 0.5 inch outlet
6Solar cell based sunlight radiation meterFor Solar power measurement up to 2000 w/square meter
7Cut Models Of Photo Voltaic Cell Assembly250W,12V AND 0.5W