Upgradation Of Dhaniakhali Rh From 30 Beds To 100 Bedded State General Hospital At Dhaniakhali In The District Of Hooghly---- Supply, Installation, Testing And Commissioning Of Air- Conditioning Arrangement.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Sep 2021
0 days left
EMD
97000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhaniakhali → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Upgradation Of Dhaniakhali Rh From 30 Beds To 100 Bedded State General Hospital At Dhaniakhali In The District Of Hooghly---- Supply, Installation, Testing And Commissioning Of Air- Conditioning Arrangement.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of 5.0 ton capacity wired concealed type Split AC of rated cooling capacity-60000 BTU/hr. with 2 nos. twin rotary compressor, 2 nos. IDU of rated power supply- 230V-1Ph- 50 Hz., 1 no. ODU of rated power supply- 400V-3Ph- 50 Hz.Air-flow/per IDU :- 1000 CFM.(Make: Hitachi/Daikin/ Carrier) |
| 2 | Supply of 7.5 ton capacity wired concealed type Split AC of rated cooling capacity-90000 BTU/hr. with 3 nos. twin rotary compressor, 3 nos. IDU of rated power supply- 230V-1Ph- 50 Hz., 1 no. ODU of rated power supply- 400V-3Ph- 50 Hz.Air-flow/per IDU :- 1000 CFM.(Make: Hitachi/Daikin/ Carrier) |
| 3 | Supply of 4.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 48000 BTU/hr. with 2Nos.Rotary compressor, 2nos. IDU of rated power supply-230V-1ph-50Hz., 1no. ODU of rated power supply-230V-1ph-50Hz, R410A Refigerant. Air-flow/per IDU:- 800CFM. ( Make: Hitachi/Daikin/ Carrier) |
| 4 | Supply of 3.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos.Rotary compressor, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz, R410A Refigerant. Air-flow/per IDU:- 600CFM. ( Make: Hitachi/Daikin/ Carrier) |
| 5 | Supply of 2.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1Nos.Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz, R410A Refigerant. Air-flow/per IDU:- 800CFM. ( Make: Hitachi/Daikin/ Carrier) |
| 6 | Erection and commissioning charges for the above-said 7.5/5.0 TR ton Concealed type Split Air Conditioner |
| 7 | Erection and commissioning charges for the above-said 4.0/3.0 TR ton Concealed type Split Air Conditioner |
| 8 | Erection and commissioning for the above-said 2 TR Concealed type Split Air Conditionerincl. Supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C.. |
| 9 | Charges for scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of 7.5/5.0/4.0/3.0 Tr Concealed type Split Air Conditioner machine |
| 10 | Supply, installation & commissioning Copper Refrigeration pipe line for liquid and suction line with supports, brackets and 13 mm thick nitryle rubberInsulation and wrapping insulation of aerotape as per direction of EIC. |
| 11 | a) Liquid Line (3/8\" dia ) with 13 mm thick nitryle rubber insulation with Al foil covered (Cu pipe make- Ryoku/Rajko /Mandev) (insulation make- Accroflex/ Supreme) |
| 12 | b) Liquid Line (1/4\" dia ) with 13 mm thick nitryle rubber insulation with Al foil covered (Cu pipe make- Ryoku/Rajko /Mandev) (insulation make- Accroflex/ Supreme) |
| 13 | c) Suction line (5/8\" dia ) with 13 mm thick nitryle rubber insulation with Al foil covered (Cu pipe make- Ryoku/Rajko /Mandev) (insulation make- Accroflex/ Supreme) |
| 14 | Control cabling by supply & fixing FRLS copper cable from ODU Unit to IDU unit of Concealed Split AC (Make- Polycab/ Havells/ KEI/Finolex as approved by E.I.C) |
| 15 | 4 Core 2.5 sq. mm. Communication Cable |
| 16 | 3 Core 2.5 sq. mm. Communication Cable |
| 17 | Supply & Laying Extra Add-on items- 5/8\"(for suction), 0.6 mm thick& 1/4\"(for discharge), 0.6 mm thick, copper refrigerant pipe with 9mm thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5/2.0 TR A.C. Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC \"T\", elbow, bend etc as per direction of E.I.C |
| 18 | Supply of Microprocessor based air cooled 8.5TR ceiling suspended ductable type Split Air Conditioner having nominal cooling capacity of 102000 BTU/hr. at ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3PhAC supply. Each unit consist of Scroll/Twin Rotary compressor with R-410A Refrigerant .(one running Condition & One Stand By Condition.)(Make: Hitachi/Daikin/Carrier as approved by E.I.C) |
| 19 | Supply of Microprocessor based air cooled 11.0TR ceiling suspended ductable type Split Air Conditioner having nominal cooling capacity of 132000 BTU/hr. at ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3PhAC supply. Each unit consist of Scroll/Twin Rotary compressor with R-410A Refrigerant .(one running Condition & One Stand By Condition.) (Make: Hitachi/Daikin/Carrier as approved by E.I.C) |
| 20 | Erection and commissioning charges for the above-said 8.5/11 TR ton Ductable type Split Air Conditioner |
| 21 | Charges for scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of 8.5/11 TR Ductable type Split Air Conditioner machine |
| 22 | Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410 refrigerant & 13 mm thick Nitrile Rubber Insulation tube with supports & brackets as per direction of EIC. |
| 23 | a) Liquid Line ( 1 1/8\" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon) (Insulation make - Accroflex/Supreme)(from 11.0TR/8.5TR Condenser unit to AHU) |
| 24 | b) Suction Line (5/8\" dia) with 13 mm thick nitrile rubber insulation with Al. Foil covered (Cu Pipe Make - Rajko/Ryoku/Nippon) (Insulation make - Accroflex/Supreme)(from 11.0TR/8.5TR Condenser unit to AHU) |
| 25 | Charges for scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of 11.0 & 8.5 Tr Ductable Split Air Conditioner |
| 26 | Control cabling by supply & fixing FRLS copper cable from ODU Unit to IDU unit of Concealed Split AC (make- Polycab/ Havells/ KEI/Finolex) |
| 27 | 3 Core 1.5sq. mm. Communication Cable 11.0 & 8.5 Tr Ductable Split |
| 28 | 3 Core 2.5 sq. mm. IDU Power Cable 11.0 & 8.5 Tr Ductable Split |
| 29 | Supply, fabrication and installation of sheet metal duct of the following sizes completewith accessories like anchor fastners, MS angle / rod for support, dampers, turning vanes etc.in accordance with approved drawing of ducting layout. |
| 30 | 22 SWG( Make:- TATA/SAIL/JINDAL) |
| 31 | 24 SWG( Make:- TATA/SAIL/JINDAL) |
| 32 | Acoustic lining of duct work with 9mm thick Open shel Nitrile Rubber. (K-Flex / Amracell / Supreme) |
| 33 | Supply &fixing of 10 mm thick Opec Cell Nitrile rubber thermal insulation under duct complete with all accessory as required.(Make- Supreme,K-flex.)as perdirection EIC.. |
| 34 | Supply & Fixing of22 G GI aerofoil blades type FireDampers complete with linkages, levers, fittings, supports, all accessoriesany other item required to make the system complete as per direction of E.I.C. |
| 35 | Supply & Fixing of22 G GI aerofoil blades type Volume Control Dampers complete with linkages, levers, fittings, supports, all accessoriesany other item required to make the system complete as per direction of E.I.C. |
| 36 | SITC of aluminium Power coated supply air Diffuser with VCD(Make: Air Kolkata/Primier) |
| 37 | SITC of aluminium Power coated return air Diffuser without VCD(Make: Air Kolkata/Primier) |
| 38 | Supply & laying PVC Drain Pipe 25mm dia with 6mm thick NitrileRubber Insulation (Make: Suprime/Oriplast) |
| 39 | Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame for installation of outdoor unit of 5.0,3.0,4.0 Tr Concealed split & 11.0 & 8.5 Tr Ductable Split AC incl. drilling holesin each channel, cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm)iron with necessary painting. as per direction of E.I.C. |
| 40 | Supply & Fixing flexible Double Canvas Connection |
| 41 | Supply & Fixing Aluminium powder coated Continuous Grill. (Mk. System Air/ Premire /Air Master as approved by E.I.C) |
| 42 | Fabrication & erection of IDU Covering unit made of 3 mm thick ACP Board( MAKE-Aludecor/or others reputed make as approved by E.IC) incl. Al channel & complete with linkages, levers, fittings, supports, all accessoriesany other item required to make the system complete as per direction of E.I.C. |
| 43 | Charges for trap door with 3 mm thick ACP board( MAKE-Aludecor/or others reputed make. ) complete with linkages, levers, fittings, support all accessories for IDU maintenance as per direction of EIC. |
AI Tender Summary
Tender Timeline
Sep 17, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 30, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender