Water Supply And Fencing Construction Of Water Storage Tank Including Water Supply Line And Barbed Wire Fencing At Kundao Bop Of 25Th Bn Itbp, BOP Kundao of 25 BnITBP, 11 kms on foot distance-Arunachal Pradesh

Indo Tibetan Border Police Force-ITBP has published Water Supply And Fencing Construction Of Water Storage Tank Including Water Supply Line And Barbed Wire Fencing At Kundao Bop Of 25Th Bn Itbp. Submission Date for this Tender is 24-09-2021. Water Pipe Line Tenders in BOP Kundao of 25 BnITBP, 11 kms on foot distance Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29250393
Water Supply And Fencing Construction Of Water Storage Tank Including Water Supply Line And Barbed Wire Fencing At Kundao Bop Of 25Th Bn Itbp
Open Tender
Indian
Arunachal Pradesh
BOP Kundao of 25 BnITBP, 11 kms on foot distance
24-09-2021

Tender Details

Water Supply And Fencing Construction Of Water Storage Tank Including Water Supply Line And Barbed Wire Fencing At Kundao Bop Of 25Th Bn Itbp

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Construction of Water Storage Tank including water supply line and Barbed Wire Fencing at Kundao BOP of 25th BN ITBP
Sl. No. Item Description
1Earth work in excavation over areas (exceeding 30 cm in depth 1.5 m in width as well as 10 Sqm in plan) including disposal of excavated earth,lead up to 50 m, disposed earth to be levelled and neatly dressed: All kinds of soil.
2Excavation work in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dresing of sides and ramming of bottoms lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed , within a lead of 50 m.Ordinary rock
3Filling available excavated earth ( excluding rocks) in plinth side of foundation, under floors in layers not exceeding 20 cm in depthincluding, watering, ramming consolidating and dressing completelead up to 50 m and lift up to 1.5 m,
4Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
5Felling old dead trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 120 cm girth upto and including 240 cm girth.
6Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
7Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
8Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level:1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
10Centering and shutturing incl. strutting, proping etc and removal of form work for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
11Centering and shutturing incl. strutting, proping etc and removal of form work for : Suspended floors, roofs, landings, balconies and access platform
12Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . MS Bardeformed TMT bars , conforming to IS 1786-1985: Thermo-Mechanically Treated
13Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 Cement : 6 coarse sand)
14Applying priming coat with: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
15Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
16Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.: With G.I. barbed wire
17Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
18Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore
19Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal bore (External Work)
20Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore (External Work)
21Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
22Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
23Providing and applying integral crystalline slurry of hydrophilic in nature for waterprofing treatment to the RCC structures like retaining walls of the basement , water tanks, roof slabs ,podiums ,reservior , sewage, water treatment plant, tunnels/subway and bridge etc ,prepared by mixing in the ratio of 5:2 (5 parts intergral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with help of synthetic fiber brush. the material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. the work shall be carried out all complet as per specifiction and the direction of the engineer-in-charge.The product performance shall carry guaranteed for 10 year against any leakage.: For vertical surface two coats @ 0.70kg per sqm per coat
24Providing and applying integral crystalline slurry of hydrophilic in nature for waterprofing treatment to the RCC structures like retaining walls of the basement , water tanks, roof slabs ,podiums ,reservior , sewage, water treatment plant, tunnels/subway and bridge etc ,prepared by mixing in the ratio of 5:2 (5 parts intergral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with help of synthetic fiber brush. the material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. the work shall be carried out all complet as per specifiction and the direction of the engineer-in-charge.The product performance shall carry guaranteed for 10 year against any leakage.For horizontal surface one coats @ 1.10kg per sqm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail