| 1 | (Sub Head-I SITC of A.C.\"s) Supplying, installation, testing & commissioning of following type & capacity of BEE 5 Star rating inverter with copper coil & fan motor, air cooled condenser with inverter compressor, condenser coil, control panel cordless remote including kit (Suitable size copper pipe & power cable upto 3 mtr length) and duly charged with eco friendly refrigerant (as per OEM standard) suitable for operation on single phase 220V+/- 10% 50Hz AC etc complete as per direction of Engineer-in-Charge. Split AC 1.5 TR |
| 2 | (Sub Head-I SITC of A.C.\"s) Supplying, installation, testing & commissioning of following type & capacity of BEE 5 Star rating inverter with copper coil & fan motor, air cooled condenser with inverter compressor, condenser coil, control panel cordless remote including kit (Suitable size copper pipe & power cable upto 3 mtr length) and duly charged with eco friendly refrigerant (as per OEM standard) suitable for operation on single phase 220V+/- 10% 50Hz AC etc complete as per direction of Engineer-in-Charge. Split AC 1.8 TR to 2 TR |
| 3 | (Sub Head-I SITC of A.C.\"s) Supplying, installation, testing & commissioningof following type & capacity of BEE 5 Star rating with rotary compressor, control panel cordless remote and duly charged with eco friendly refrigerant( as per OEM standard) suitable for operation on single phase 220V+/- 10% 50Hz AC etc complete as per direction of Engineer-in-Charge. Window 1.5 TR |
| 4 | (Sub Head-I SITC of A.C.\"s) Providing and fixing copper piping for refrigerantalong with insulation between indoor andoutdoor unit suitable for inverter Split type 1.5 TR/2 TR AC including all accessoriesetc as per the site requirement need and as per direction of Engineer-in-Charge. |
| 5 | (Sub Head-I SITC of A.C.\"s) Providing & laying of following sizePVC insulated & PVC sheathed multistrand copper conductorflexible cable of 1.1 KV grading, confirming to IS 7098 part-1 including connections with the help ofsuitable size of ferrules/thimbles, 3 pintop of suitable size etc.as per direction of Engineer-in-Charge. 4 x 2.5 sqmm(For indoor unitto outdoor unit) |
| 6 | (Sub Head-I SITC of A.C.\"s) Providing & laying of following sizePVC insulated & PVC sheathed multistrand copper conductorflexible cable of 1.1 KV grading, confirming to IS 7098 part-1 including connections with the help ofsuitable size of ferrules/thimbles, 3 pintop of suitable size etc.as per direction of Engineer-in-Charge. 3 x 2.5 sqmm ( For outdoor unit to power plug point) |
| 7 | (Sub Head-I SITC of A.C.\"s) Providing and fixing 25mm dia PVC Heavy duty pipe with rubber insulation for sweating water drain from the Indoor Unit withclamp & other accessories etc. complete as per direction of Engineer-in-Charge. |
| 8 | (Sub Head-I SITC of A.C.\"s)Providing and fixing wall/ floor mounted adjustable stand fabricated with M.S sheet of size 40mmx40mmx5mm (nominal size), duly powder coated suitable for outdoor unit on the existing wall/ floor with the help of nuts & bolts or dash fastener etc complete as per direction of Engineer-in-Charge. |
| 9 | (Sub Head-I SITC of A.C.\"s)Providing Copper guard preventive coating (thermolic coating) on expose copper pipe, cooling coil of 1.5 TR/ 2.0 TR Split A.C. & 1.5 TR Window A.C. to prevent from corrosion etc complete as per direction of Engineer-in-Charge. |
| 10 | (Sub Head -II AMC of A.C.\"s) Comprehensive Annual Maintenance of 1.5 / 2.0 TR capacity Inverter type Split AC as per manufacturer recommendation including servicing of the AC, Refrigerant gas charging , motor, wiring, refrigerant copper pipe with insulation & drain pipe rubber insulation etc complete with all parts required for healthy and proper functioning of the Air Conditioning as per the direction of Engineer-In Charge. (This include all the materials, labour etc involved in doing the AMC, nothing will paid extra on any account)Five Years AMC period Including Defect Liability period |
| 11 | (Sub Head -II AMC of A.C.\"s) Comprehensive Annual Maintenance of 1.5 TR capacity Window typeAC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging, motor, wiring, etc complete with all parts required for healthy and proper functioning of the Air Conditioning as per the direction of Engineer-In Charge.(This include all the materials, labour etc involved in doing the AMC, nothing will paid extra on any account)Five Years AMC period Including Defect Liability period |
| 12 | (Sub Head-IIICredit Item) Dismantling the following type A.C.\"s and capacity and taking away dismantled item as credit item on buyback basis etc as required and as per direction of Engineer-in-Charge Split AC 1.5 TR / 2TR |
| 13 | (Sub Head-IIICredit Item) Dismantling the following type A.C.\"s and capacity and taking away dismantled item as credit item on buyback basis etc as required and as per direction of Engineer-in-Charge Window AC 1.5 TR / 2TR |