| 1 | Electrification |
| 2 | od21647/2021_2022 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III excluding arm bracket including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters |
| 3 | od21693/2021_2022 : Supply and fixing of 1.5mtr long hot dip galvanised PU Painted Single arm Designer bracket suitable to mount on pole having 70mm top diameter |
| 4 | od21649/2021_2022 : Fabrication , supply , erection and assemblingM.S. clamps with suitable nuts and bolts for fixing pole or pipeincluding painting whole portion as per standards |
| 5 | 90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 6 | 14.10 : Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 7 | od135301/2020_2021 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars CPWD Code 5.22.6 |
| 8 | 90.6.5.9 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm |
| 9 | 90.12.5.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 10 | 9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 11 | 90.12.9.3 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size |
| 12 | 90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 13 | 90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size |
| 14 | 5.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 15 | 90.16.5.5 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 16 | od135306/2020_2021 : Supply and providing 25x6mm brass nut and bolt etc. as required. |
| 17 | od135307/2020_2021 : Supply and providing 12x3mm brass nut and bolt etc. as required. |
| 18 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 19 | od135308/2020_2021 : Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 20 | od135309/2020_2021 : Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 21 | 90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 22 | 90.14.3.2 : Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardU\" section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 23 | 90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 24 | od135310/2020_2021 : Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 25 | od135311/2020_2021 : Supplying and fixing 32, HRC Fusewith HRC Fuse link with connections, in existing meter board |
| 26 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 27 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 28 | 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 29 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 30 | od21651/2021_2022 : Supply, conveyance & installation ofHensel make IP 66 / IP 67 weather proof 180x 130 x 77 mm cable junction Box ( KF 1006 B) with Terminal Set 2.5-6 sq.mm Copper |
| 31 | od20845/2021_2022 : Supply and fixing Auto / Manual selector switches in the existing panel (L&T61152 2p 2w 10A) |
| 32 | od135417/2020_2021 : Supply and fixing 25A AC1, MNX 9, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 33 | od135313/2020_2021 : Supplying and fixing 24Hours Timer for operating ON-OFF function in 1the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. |
| 34 | od135314/2020_2021 : Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00Sqmm single run |
| 35 | od135315/2020_2021 : Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run |
| 36 | 2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 37 | od20847/2021_2022 : Supplying and laying 10 SWG copper. wire at 0.60metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required. |
| 38 | od20849/2021_2022 : Supply and fixing 63mm dia 6Kgff/cm2PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe) |
| 39 | od20855/2021_2022 : Fabrication,supply,conveyance and installation of Granite name board indicating the cost involved, the dates of commencement, completion, inauguration etc on existing base as required- |