Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra, Ge West Agra-Uttar Pradesh

Military Engineer Services-MES has published Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra. Submission Date for this Tender is 30-09-2021. Flasher Light Tenders in Ge West Agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29222154
Corrigendum : Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra
Open Tender
Indian
Uttar Pradesh
Ge West Agra
30-09-2021

Tender Details

Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra Provn Of 60 Security Light With Steel Tubular Poles At 60 Para Fd Hospital And Certain Minor Works Under Ge W Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-09-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work : PROVN OF 60 SECURITY LIGHT WITH STEEL TUBULAR POLES AT 60 PARA FD HOSPITAL AND CERTAIN MINOR WORKS UNDER GE (W) AGRA
Sl. No. Item Description
1Supply, installing, commissinig& testingcomplete manufacturered & assembled by OEM,static, silent complete unit mounted on comman MS structural steel base frame total unit enclosed in acoustic type sound proof,as per PSB norms, water cooled, diesel engine driven generating setcapable of delivering 8 KW (10 KVA),415 Volts, AC, three phase, 4 wire system supply, 50 HZ at power factor 0.8 (minimum). for continouns 08 Hrs running & 01 Hrs running at 10% overload continously, the DG Set shall consists of self starting type diesel engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete withrelay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity10 KVA directly coupled to a matching alternator of the make as recommanded by OEM, through flexible coupling including suitable capacity & size electric pannel, auto& mannuallyself starting with 12 volt DC arrengement on mains faluire,engine control panel standardized by manufacturer, fuel tank of capacity for 12 hr running with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe completesuitable for conditions prevalent at Agra (where work to be executed ) capacity of engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation ( of suitable size leaving atleast 0.5 M all around for ease of movement and 0.3 M height from ground level), anti viberation pads, including all features to comply with latest CPCB guidelines and comprising of followings :- Make-Kirloskar green/Greaves cotton/Ruston/ Eicher/Cumins
2(i) Engine (Prime Mover) :-Diesel engine 1500 RPM, direct injection, four stroke,Water cooled,turbo charged, confermimg as per IS:10001/ 10002 capale of giving adequate BHP to drive Alternator capable of delivering 10 KVA (8 KW) for 08 Hrs continously on full load and 01 Hrs at 10% overload at outdoor atmospheric conditions at Agra, (Taking all derating factor into consideration), 12 Volt( as per manufacturer recommendations) DC battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meter and also including self starter system, battery charging alternator 12 volt, governing class G3 and Engine protection system ( Shut down, High water temperature, low lub oil, oil pressure, over speed etc ) fuel tank and first fill of lub oil and other consumables etc. (II) Alternator :-Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 10 KVA, minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H" salient pole, confirmimg as per IS: 13364 revolving field, single bearing automatic voltage regulator ( AVR type field exiding) coupled through flexible coupling with and to match the above engine. (III) Base Plate :- Made out of structural steel as per manufacturer"s recommended design/ specification, capable to take load of the enginen with alternator.
3(IV) Acoustic enclosure :-Out door type Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reduring the sound level as per latest CPCB norms. (V) Electric control PANEL:-Factory made cubical type fllor mounted LT panel board,outdoor type made out of MS angle not less than 40x40x6 mm and 3.15 mm thick MS CRCA sheet,Front & rearopening type, with locking arrengment protection class IP-64,duly powder coated ,with electrolytic grade copper busbar of 100 amp capacity, TPN,four wire system, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings-: (a)MCCB 415 V 63 Amp rating 4 pole 36 KA rupturing capacity DPX³ 160 ,microprocessor based release,draw out type,specially fixed with incoming supply with overload short circuit and earth fault protection-1 Nos with suitable rating HRC back up fuses.Make-Legrand Cat Part No. 4200 93 or equivelant model of L&T / Havrells, ABB. (b)Digital multifunction meter Square type to measur volt,Amp,P.F.Frequency,KWH etc Make-HPL/L&T, (c)Phase indicating lamps (R-Y-B) -01 set of three lamps for each Incomming/outgoing circuit. (d)All Standard relays,circuits and protection required for automatic operation of genset.
4(VI) Fuel tank:-(i) Suitable for storage adequate qty of diesel for 12 Hrs operation of Gen Set. (ii)Tool kit, & spare parts for servicing such as fuel filters, fan belt etc as recommanded by OEM for one year maint.
5S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65/66 protection, power consumption < 70 W and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temprature range 0-450c, THD<10%, colour tempreature 5700K, surge protectionin cm 3.5KV 50000 burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to steel pole all as specified and directed. Make :- Wipro cat Part No. LR02-781-XXX-57-XX or equivalent of Havells/Phillips / Bajaj.
6Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified & as directed. Note: Foundation & coping will be measured & paid separately under respective item.
7Supply and fix steel tubular swaged poles type 410 SP-55 (11.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified & as directed. Note: Foundation & coping will be measured & paid separately under respective item.
8Supply and fix on pole, dust proof, vermin proof, out door type polycarbonate box including MCB SPN 6 Amps, SPN bus bar, insulator, GI nut, bolts and washers and Aluminum lugs etc with and including Fl clamp made out of 30mmx3mm, nut and bolts complete all as specified and directed. Make: Sintex, National/HPL
9S & Laying, jointing, commissioning and testing XLPEinsulated steel armoured heavy duty elect power cable 1100 volt grade, stranded aluminium conductor cross sectional area 25 Sqmm 4 core laid in trenches or fixed to wall with saddles or layed in duct or passing through pipe for making electrical connection between LT panel/ feeder pillar box and DBs compele all as specified and as directed.
10S & Laying, jointing, commissioning and testing XLPEinsulated steel armoured heavy duty elect power cable 1100 volt grade, stranded aluminium conductor cross sectional area 16 Sqmm 2 core laid in trenches or fixed to wall with saddles or layed in duct or passing through pipe for making electrical connection between LT panel/ feeder pillar box and DBs compele all as specified and as directed.
11M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mmformed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
12Material and labour for GI tubing light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed. (Clamp for fixing pipe, nuts, bolts, washers shall be measured separately)
13Excavation in trenches soft/loose soiln.exc 1.5 mtr wide but exc 1.5 mtr depth in for pole foundation and getting out including forming bottom surface complete all as specified and as directed by Engineer-in-Charge.
14M&L for PCC 1:4:8,type D-2 (Using 40mm graded stone aggregate) in foundations, filling and mass concrete for ploe foundation complete all as specified and as directed.
15M&L for pole coping with PCC 1:3:6, type C-2 (Using 20 mm graded stone aggregate) including necessary use & waste of form work above ground level complete all as specified and as directed.
16Excavation in trenches not exc 1.5 mtr wide, not exc 1.5 mtr depth and getting out in soft/loose soilcomplete all as specified and as directed.
17Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
18Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
19Supply & spreading in trenches with clean dry sand unwashed including gently punning around cable protection complete all as specified and directed.
20Supplying and laying un-reinforced precast concrete cable cover, LV, type-I, flat, size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed.
21Supply and fixing 100 watt ,230 V AC outdoor type, 5700KLED security Flood light made out of pressure die cast aluminium housing with toughned glass, IP66 protection and impact resistance IK07, mounted on top of the pole with cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduitfrom celling rose to building security light fittings complete all as specified and directed. Make : WIPRO CAT PartNo. LF20-122-060-57-XX or equivalent of Havells/Philips/Bajaj
22Supply, installation, commissioning and testing of feeder pillar box, kisok outdoor type, CPRI type tested, LT 440 volts, 50 Hz, 3 Phase, 4 wire supply, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3 mm thick MS sheet CRCA on angle iron 50x50x6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) as recommanded by manufacturer or directed including earth work complete comprising of following :-
23Incoming:- (a) Bus bar chamber compressing 4 Nos Aluminum strip bus bars PVC insulated made of Aluminum strip of size (40x5mm), PVC sheathed with colour coding. (b) MCCB having current rating 100 Amps with rupturing cap 16 KA, DPX³ 160, AC 415 Volts four pole with microprocessore release complete with spreader links. - 01 No. Make-Legrand Cat Part No.4200 15 or equivelant model of L&T / Havrells, ABB. (c) Multifunctional digital panel meter with LED display flush mounting type of size 96x96 mm accuracy class-I, suitable for CTs with secondary current 5 Amp. Make - L&Tcat part No. WDV303FC000 or equivalent of make Schneider or AE - 01 No. (d) Change over switchfour pole front handle operated on load type 63 Amps, - 01 Nos, Make : Havells, L&T
24Outgoing :- (a) MCCB having current rating 63 Amps with DPX³ 160 rupturing cap 16 KA, AC 415 Volts, 3 pole with thermal magnetic release complete with spreader links. - 02 Nos Make-Legrand Cat Part No.4200 03 or equivelant model of L&T / Havrells, ABB. (b) MCB 4 Pole having current rating 63 Amps with DPX³ 160 rupturing cap 16 KA, AC 230 Volts, 2 pole, "C" curve type. - 01 No. Make-Legrand Cat Part No.4200 13 or equivelant model of L&T / Havrells, ABB. (c) MCB DP having current rating 40 Amps with rupturing cap 10 KA, AC 230 Volts, 2 pole, "C" curve type. - 04 Nos. (d) Street light control switch comprising of :- (i) Time switch multifunctional digital for automatic switch ON/OFF of street lights suitable for working on 110 to 240 Volts. - 02 Nos (ii) Air break contactor AC 415 Volts, 50 Hz, 3 pole, 63 Amp, AC-1 rating with operating coil 220 volts. (iii) MCB SP 2.5 Amps - 02 Nos NOTE: All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
25Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 Ltrs per hour and storage capacity of 80 Ltrswith 2 Nos cold water outlet complete all as specifiedand directed.
26Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and directed.
27M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated, unsheathed stranded copper conductor FRLS cable for one 15 amp socket independent point controlled by one, one way switch cable drawn in and including medium grade ISI marked PVC conduit not less than 20mm dia and its acessoriesalongwith one run of 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor (green colour)including sunken type pressed steel terminal box of 1.2 mm wall thickness duly painted inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer including 3 mm thick ISI marked plastic laminated sheet cover fixed with cadmium plated MS screws and washers for mounting switches, sockets, lamp holder, etcincluding all fixing accessories including cutting chases in brick wall and making good disturbed surface as per existing complete all as specified and directed. Note: Wiring shall be made as per colour code in IS for Phase, neutral and earth.
28Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.39991 or equivalentas approved by GE.
29Supply and fixsocket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed. Make: Anchor Cat No.39994 or equivalentas approved by GE.
30M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes :-Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
31Supply & fix MCB SP, 6 to 32 Amps, "C" curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI markedcomplete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
32Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm (3/4”) dia with all fittings complete all as specified and as directed at site.
33Supply and lay pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia with all fittings complete all as specified and as directed at site.
34Supply and fix brass stop Valve high pressure screwed both ends suitable for fixing in steel water tubing of size 20 mm (3/4”) dia pipe complete all as specified and as directed.