Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transformer, Provn Of Standby Power Supply To Mpr Bldg, Special Repairs To Existing Lights At 8 Sqn At Af Station, Bareilly Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transfo, Bareilly-Uttar Pradesh

Military Engineer Services-MES has published Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transformer, Provn Of Standby Power Supply To Mpr Bldg, Special Repairs To Existing Lights At 8 Sqn At Af Station, Bareilly Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transfo. Submission Date for this Tender is 18-12-2021. Voltage Stabiliser Tenders in Bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29204767
Corrigendum : Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transformer, Provn Of Standby Power Supply To Mpr Bldg, Special Repairs To Existing Lights At 8 Sqn At Af Station, Bareilly Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transfo
Open Tender
Indian
Uttar Pradesh
Bareilly
18-12-2021

Tender Details

Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transformer, Provn Of Standby Power Supply To Mpr Bldg, Special Repairs To Existing Lights At 8 Sqn At Af Station, Bareilly Installation Of 20 Kva 3 Ph Voltage Stabilizer And Isolation Transformer, Provn Of Standby Power Supply To Mpr Bldg, Special Repairs To Existing Lights At 8 Sqn At Af Station, Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Sep-2021 Replacement of BOQ and Revision of PS pages. BOQ 04-10-2021
2 04-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-10-2021
3 11-Oct-2021 EXTENSION OF CRITICAL DATES Date 18-10-2021
4 18-Oct-2021 Further extension of critical dates. Date 25-10-2021
5 25-Oct-2021 Further extension of critical dates.. Date 08-11-2021
6 09-Nov-2021 Further extension of critical dates... Date 18-11-2021
7 18-Nov-2021 INSTALLATION OF 20 KVA 3 PH VOLTAGE STABILIZER and ISOLATION TRANSFORMER, PROVN OF STANDBY POWER SUPPLY TO MPR BLDG, SPECIAL REPAIRS TO EXISTING LIGHTS AT 8 SQN AT AF STATION, BAREILLY Date 27-11-2021
8 27-Nov-2021 INSTALLATION OF 20 KVA 3 PH VOLTAGE STABILIZER and ISOLATION TRANSFORMER, PROVN OF STANDBY POWER SUPPLY TO MPR BLDG, SPECIAL REPAIRS TO EXISTING LIGHTS AT 8 SQN AT AF STATION Date 07-12-2021
9 07-Dec-2021 INSTALLATION OF 20 KVA 3 PH VOLTAGE STABILIZER and ISOLATION TRANSFORMER, PROVN OF STANDBY POWER SUPPLY TO MPR BLDG, SPECIAL REPAIRS TO EXISTING LIGHTS AT 8 SQN AT AF Date 18-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 49500.0 /-
Tender Value
INR 24.75 Lakhs /-

BOQ Items

NAME OF WORK: - INSTALLATION OF 20 KVA 3 PH VOLTAGE STABILIZER & ISOLATION TRANSFORMER, PROVN OF STANDBY POWER SUPPLY TO MPR BLDG, SPECIAL REPAIRS TO EXISTING LIGHTS AT 8 SQN AT AF STATION, BAREILLY.
Sl. No. Item Description
1Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
2Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25cm in any type of soil.
3Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
4Supply and spread river sand as in cushioningfor UG cable allas specifiedin clause 19.75 of SSRPart I. [Note: Punned down thickness shall be considered for payment]
5M&L for well burnt Sub class "B", modular bricks laid dry, flat, over the cable abutting each other, complete all as specified and directed.
6Supply, laying, testing andcommissioning of LT XLPE insulated, armouredheavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 3½ core x 95 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
7Supply, laying, testing andcommissioning of LT XLPE insulated, armouredheavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 3½ core x 25 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
8Supply, laying, testing andcommissioning of LT XLPE insulated, armouredheavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 4 core x 16 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
9M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary T&P including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as directed.
10S&F of 40 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches, in surface, under floor or fixed to wall complete all as specified and directed.
11S&F of 50 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches, in surface, under floor or fixed to wall complete all as specified and directed.
12S&F suspended/ surface type High bay luminaire not less than 140 Watt, environmental friendly, energy saving long life corrosion resistant vertical surface mounting pressure die-cast aluminium housing and control gear with high power LED with all mounting accessories for fixing to truss of hangar/ MT garage etc complete prewired with flexible 3 core 1.50sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and as directed including taking down existing unserviceable light fitting. [Model: SAUSERPLUSHBP150WLED85790DTOLTG of make: Havells or BY415P LED160S CW HE WB FG PSU GR XTFCL S5 of make Philips or BGHBM NXT B 195L WH NB SD of make: Bajaj]
13Supply and fix die cast aluminium LED Flood light not less than 110W IP 66 with high power LEDs, integral flood light with driver inside a PDC housing including all fittings, clamps, angle frame etc for fixing on wall/ pole etc complete all as specified and as directed including taking down existing unserviceable light fitting. [Make: Cat Part No. BJFL 120W LED I of make: Bajaj or LF20-122-060-57-G2 of make: Wipro or BVP192 LED110 CW HO NB FG GR PSU of make: Philips].
14M&L for sub main wiring complete with two runs of single core 1.5 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories including provision of earth continuity wire with same cable as for wiring but in green colour all as specified.
15Supply, installation, testing & commissioning of servo motor operated automatic line voltage corrector (LVC) of capacity 20 KVA copper wound and wired indoor type conforming to IS:9815 (Pt-I) / 1994 suitable for input voltage range 300-480 Volts, 3 phase line voltage correctors connected in star and enclosed in a single enclosure with common control panel and shall be suitable for imbalance input voltage, rated out put speed / 415 ± 1% volts for 3 phase 50 HZ LVC and speed / rate of correction of voltage shall not be less than 08 volts per second per phase having features of high / low voltage cut off, over load / short circuit protection, single phase preventer and phase reversal cut off and by pass arrangement complete with first fill of transformer oil all as specified and as directed.
16Supply, install, commissioning and testingof Isolation transformer of capacity 20 KVA, 3 phase, 415 Volts, 50 Hz, ONAN type cooled oil immersed copper wound indoor type complete with first filling of IS; 335 ISI marked filtered & Dehydrated Transformer oil, electrostatic shield between primary 415 V in Delta connected & secondary 415V Star connected complete & other standard fittings/ accessories with vector group symbol Dyn-11 , cable box on in coming and out going with cable glands complete all as specified and as directed.
17M&L for earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
18Supply and fixing of 20 X3 mm size copper strip as in earth continuity conductor or main earthing lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed.
19S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, providing 10mm thick fibre sheet of size 15x15cm below the test point to avoid direct contact with wall including enclosing the test point with 1.6mm thick MS sheet front openable box duly painted complete all as directed by Engineer -in-Charge.
20Supply, installation, testing and commissioning factory made LT feeder pillar box, indoor type, wall mounted of size 1000x900x450mm suitable for 415 Volts 3 phase 4 wire system, 50 Hz supply with aluminium bus bar of rating 200 Amps for phases & neutral installed on porcelain/ epoxy insulators; control wiring with PVC insulated multi-stranded copper conductor cable 1100 V grade; the panel shall be dust proof, vermin proof (IP-54) duly powder coated, made out of 2mm thick CRCA sheet mounted on wall with suitable anchor fasteners, front openable with double shutters and locking arrangement complete all as specified including housing the following accessories: Incoming: (i) MCCB 63 Amps, 4 pole, 16 KA - 01 No (ii) Voltmeter 0-500 Volts, square flush pattern, digital type - 01 No (iii) Ammeter 0-400 Amps, square flush pattern, digital type - 01 No (iv) LED type indicating lamps RYB- 01 set (v) Alarm system to indicate the commercial power failure Outgoing: (i) MCCB 40 Amps, 4 pole, 16 KA, 415 Volts - 02 Nos
21Supply, laying, testing andcommissioning of LT XLPE insulated, armouredheavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 3½ core x 35 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
22M&L for Chemical Earthing with copper earth plate electrode 900 x 600 x 5 mm thick buried directly in ground, earth pit not less than 4.70 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.60 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnesium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (up to 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65mm bore light grade GI pipe from electrode and up to the earth test point, 15 mm bore light grade GI watering pipe, GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt, charcoal dust and Magnesium sulphate filling in each alternate layers up to 1.80 m height including excavation, removal surplus soil to a distance not exc. 50 m, PCC pit inPCC(1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
23Supply and fixing of 32 X6 mm size copper strip as in earth continuity conductor or main earthing lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed.
24Supply and install Hi-wall split type Air conditioner working on single phase, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with BEE 5 Star rating and EER of minimum 3.5 of capacity and in built heating and cooling arrangement, copper wound rotary compressor with digital inverter technology suitable for CFC free refrigerant of capacity 2.0 TR including fixing of indoor and outdoor unit, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable and plug top complete all as directed by Engineer-in-Charge. [Make: Model: IC524DBTU of make Blue Star or equivalent in Daikin/ Voltas/ Carrier/ Hitachi]
25Supply & install Copper wound automatic boost / buck transformer, wall mounted with digital display for low and high voltage correction equipped with electronic transistored relay suitable for correction on single phase 50 Hz AC supply complete with volt meter and designed for input voltage of 160 volts to 260 volts and out put voltage stabilized between 215 volts + 1% of capacity 5 KVA with high low voltage and time leg relay complete all as specified and as directed.
26M&L for sub main wiring concealed complete with two runs of single core 4 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
27M&L for sub main wiring concealed complete with two runs of single core 10 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 32mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
28S&F sheet steel powder coated distribution board TPN 4 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
29S&F MCB TPN, 415 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
30S&F MCB SPN, 240 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
31S&F single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20Amps 240 Volts complete all as directed.