Military Engineer Services-MES has published Repairs And Maintenance Of Different Type Of Summer Appliances And Other Connected Works Under Age Em Ii Of Ge N Mamun Repairs And Maintenance Of Different Type Of Summer Appliances And Other Connected Works Under Age Em Ii Of Ge N Mamun. Submission Date for this Tender is 09-10-2021. Air Conditioner Tenders in GARRISON ENGINEER (N) MAMUN Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Oct-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-10-2021 |
Sl. No. | Item Description |
1 | Taking down compressor unit carefuly from the water cooler of Cap 40/80 Ltr of any make and capacity and suply and fixed new sealed compressor unit and charging of refrigerant gas (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs complete all as specified and directed. Make : Emerson Copeland/Voltas/Sidwal/Usha/Blue star Notes: 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs. 3. The contractor shall submit Purchase Vrs, warranty card etc to the Engr-in-Charge in token of purchase and it"s serviceability). |
2 | All as per Srl item No 01 above but of 60/120 Ltrs capacity . |
3 | All as per Srl item No 01 above but of 150/150 Ltrs capacity. |
4 | S&F in replacement of Starting capacitor 80/100 Mfd for water cooler (as per sample) complete all as specified and directed Make :Havells /Asian/Texla. |
5 | S&F in replacement of running capacitor 10/15 Mfd for water cooler (as per sample) complete all as specified and directed. Make: Tibcon/EPCOS/Texla. |
6 | S&F in replacement of push cock 15mm bore dia, chromium plated, inner / outer thread (as per sample) complete all as specified and directed |
7 | S&F in replacement of blowerfan blade for water cooler suitable for 1/10HP & 1/35 HP fan motorincluding new nuts/bolts any make and capacity (as per sample), complete all as specified and directed |
8 | S&F in replacement of starting relay 85002 suitable for water coolers of any make and capacitycomplete all as specified and directed. Make: Kirloskar/Sri Ram/Hi Tech |
9 | S&F in replacing of unserviceable blower motor 1/10HP for water cooler 60/120 & 150/150 ltrs capacity including nuts/bolts, single phase, 230volt AC, complete all as specified and directed. Make. Universel/AUE/Airmaster |
10 | S&F in replacing of unserviceable blower motor 1/35HP for water cooler 40/80Ltrsincluding nuts/bolts single phase, 230volt AC, Make.Universel/AUE/Airmaster |
11 | S&F in replacement of thermostat switch for water cooler anycapacity complete all as specified and directed. Make: Renutral/Indofoss/Annapurna. |
12 | S&F in replacement of condensing coil suitable for Water Cooler ofcapacity40/80, 60/120, 150/150 Ltrs (as per sample) including welding/soldering/brazing etc, at site complete all as specified and directed. |
13 | S&F in replacement of Over load protection relay forwater cooler of any capacity (as per sample) complete all as specified and directed. |
14 | S&F in replacement of 15mm dia PVC connection pipefor water cooler any cap (as per sample) complete all as specified and directed. |
15 | S&F in replacement of old unsv/burnt copper bound Fan motor (with and including frame legs and nut, bolts) including iron blade for desert cooler 1350RPM or 1/7Hp single phase 220 volt 50Hz, and making necessary electrical connection, testing complete all as specified and directed. Make: Khaitan/Aristo/AirMaster/Cool home |
16 | M&L for rewinding of desert cooler fan motor of 1/7Hp / 1/8Hp single phase 3 speed with super ennamelled copper wire of appropriate gauge with insulating material complete (after removing old burnt wire) including replacement of the unserviceable bush, shaft and testing after completion, complete all as specified and directed. |
17 | S&F in replacement of unsv water lifting submersible pump for Desert cooler single phase 220-240volts, 50Hz including connection lead, 18watt complete all as specifed and directed. Make: Khaitan/Aristo/AirMaster/Cool home |
18 | S&F in replacement 3 way PVC water distributor for desert cooler including nuts and boltsof suitable size & PVC elbow (As per sample) complete all as specified and directed. |
19 | S&F in replacement of capacitor 4mfd for desert cooler and making all necessary electrical connection all as specified and directed. Make: Havells/Tibcon/Texla |
20 | S&F in replacement front grill complete with flexible louvers for circulating of air made out of 22 gauge GI sheet for desert cooler (any make and any size)all as per site requirement including making holes, fixed with nuts and bolts complete all as specified and directed. |
21 | S&F in replacement three way speed control switch 5Amp rotary type for desert cooler (as per sample) and making all the necessary electrical connection complete all as specified and directed. |
22 | S&F in replacement side/rear/ back grill for desert cooler made out 22 gauge GI sheet (as per existing make and sizeas per site requirement) of desert cooler complete all as specified and directed. |
23 | S&F in replacement 15mm dia PVC float valve with float, ball(as per sample) suitable for water cooler/desert cooler complete all as specified and directed. |
24 | S&F in replacement Water tank for desert cooler made out 22 gauge GI sheet including suitable size nuts & bolts for fixingarrangment (as per existing size) complete all as specified and directed. |
25 | S&F in replacement of wooden wool pad set suitable size for any type Desert cooler complete all as specified and directed. |
26 | S&F in replacement side pillar made out of 22 gauge GI sheet as per existing size with nut and bolts for fixingcomplete all as specified and directed. |
27 | S&F in replacement PVCpipe 15mm dia for Desert Cooler as per site requirement (as per sample) and making necessary connection for free flow of water complete all as specified and directed. |
28 | S&F in replacementFan blade for desert cooler (as per sample) of exisinting size complete all as specified and directed. |
29 | S&F in replacement Front patti for desert cooler (as per sample) of exisinting size complete all as specified and directed. |
30 | S&F in replacement of top of cooler bodymade of out24 gauge GI sheet of suitable size for desert cooler including nuts & bolts complete all as specified and directed. |
31 | S&F in replacement plug top 5/6 Amps , 230V with connection copper lead 1.5m long suitable for 5/6Amps socket etc for desert cooler, refrigerator complete all as specified and directed. |
32 | S&F in replacement of PCB circuit, display with remote suitable for Split type AC 1.5 Ton including all electrical connections complete all as specified and directed. Make: Mitsubishi hot & cold Srl No 8001856T & 92412462 BE Model No MSZ-HP18 VA & SRK18CS-S6or equivalant as approved. |
33 | Taking down the Aqua guard carefully from the site for servicing /cleaning including replacement filter, ultra violet rod, micro carbon sand, UV membrane, PVC pipe 15mm with nut bolts, washers complete, refixing the Aqua Guard to its original position and testing complete. |
34 | S&F in replacement of capacitor 50+ 6Mfd, 6/8 pin for window / split type AC complete all as specified and directed. Make: Havells/Asian/Crompton Greaves/Texla. |
35 | M&L for burning out old paint by blower lamp of deasert cooler, scratching the surface to smooth surface, sealing the leakage with apoxy, applying a coat of red oxide primer and spray painting two coats with synthetic enamel paint of approved shade complete all as specified and directed. |
36 | All as per item 35 but for water cooler of any capacity. |
37 | Taking down compressor unit carefuly window type AC of Cap 1.5Ton of any make and capacity and suply and fixed new sealed compressor unit and charging of refrigerant gas (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs complete all as specified and directed. Make : Make : Emerson Copeland /Haier /Whirlpool/Voltas/BlueStar/LG Notes: 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs. 3. The contractor shall submit Purchase Vrs, warranty card etc to the Engr-in-Charge in token of purchase and it"s serviceability). |
38 | All as per Srl item No 37 above but of window typeAC 2Ton. |
39 | All as per Srl item No 37 above but of Split AC 1.5 Ton. |
40 | All as per Srl item No 37 above but of Split AC 2Ton. |
41 | S&F in replacement of electric blower motordouble shaft having capacity 1/5Hp/1/7Hp for 1.5/2 Ton window type AC complete all as specified and directed. Make : Airmaster /AUE/Universal |
42 | S&F in replacement of sheet metal enclosure with plug, socket and earth point and MCB 20Amps, SP 230volts complete all as specified and directed. Make: Legrand/Havells/Schneider. |
43 | S&F in replacement of condensing coil suitable for window type AC 1.5/2.0 Ton (as per sample) including welding/soldering/brazing etc at site complete all as specified and directed. |
44 | S&F in replacement of Cooling coil suitable for window type AC 1.5/2.0 Ton (as per sample) including welding/soldering/brazing etc at site complete all as specified and directed. |
45 | S&F in replacement of PCB circuit, display with remote suitable for window type AC 1.5/2.0 Ton including all electrical connections complete all as specified and directed. |
46 | S&F in replacement of PCB circuit, display with remote (as per existing) suitable for Split type AC 1.5/2.0 Ton including all electrical connections at site complete all as specified and directed suitable for site requirement. |
47 | S&F in replacement indoor unit for split AC 1.5Ton complete (comprisingPCB blower motor, swing motor), making the all connections and testing complete all as specified and directed. Make LG/Hitachi/Mitsubishi |
48 | S&F in replacement of outdoor unit for split AC 1.5Ton (hot & cold) complete withreverseble cycle valve compressor, fan with motor etc. includingmaking the all connections, charging of environ friendly gas complete all as specified and directed. Make LG/Hitachi/Mitsubishi |
49 | S&F in replacement indoor unit for split AC 2Ton complete (comprisingPCB blower motor, swing motor), making the all connections and testing complete all as specified and directed. Make LG/Hitachi/Mitsubishi |
50 | S&F in replacement outdoor unit for split AC 2Ton (hot & cold) complete withreverseble cycle valve compressor, fan with motor etc. includingmaking the all connections, charging of environ friendly gas complete all as specified and directed. Make LG/Hitachi/Mitsubishi |
51 | S&F in replacement AC cabinet (suitable for window type AC 1.5 Ton capacity) incl all accessories viz condensing coil, cooling coil/blower motor, Electronic controlling & remote, capilary, filter, reversible cycle valve hot & cold system(excluding compressor)and making all electrical connections complete all as specified and directed. |
52 | S&F in replacement of PVC front Grill suitable for window type AC 1.5/2.0 Ton(as per sample) complete all as specified and directed. |
53 | S&F in replacement reversible cycle valve including welding/soldering/brazing with suitable size of cooper pipe for window & split AC any capacitycomplete all as specified and directed. |
54 | S&F in replacement of electric blower motorSingle shaft for out door unitcapacity 1/10Hp for 1.5Ton Split type AC complete all as specified and directed. |
55 | M&L for Charging of Gas R-22 for AC of any type including necessary welding/soldering/brazing to pipe & connection complete all as specified and directed. Note: The gas shall be supplied in 450gm in each Can. |
56 | S&F in replacement Cooling blower for Split AC 2.0/1.5 Ton as per sample |
57 | S&F in replacement Condensing fan motor for Split AC as per sample |
58 | S&F in replacement Copper Pipe ½" including necessary welding/soldering/brazing complete all as specified and directed. |
59 | All as per item 58 but size ofPipe ¼" |
60 | M&L for PVC insulated flexible copper conductor 3 core 4 Sq mm1100volt grade, connected & testing complete all as specified and directed. |
61 | M&L for PVCflexible waste pipe (drain out pipe) for split AC suitable sizefixed with lugs etc on wall /floor etc. complete all as specified and directed. |
62 | M&L for taking down /refixing in position of AC, servicing of AC window /split upto 1.5/2Ton capacity, cleaning & washing of AC with brushes /chemical etc, replacement of filter complete including connection & testing complete & all as specified and directed. |
63 | M&L for angle iron frame work in repairs of size 25x25x4mm suitablefor supporting of AC"s & Desert Coolers,complete with grouting In wall in CM 1:3 or placed on floor including rollers on floors etc, making good the disturbed surfacs to match with existing complete all as directed |
64 | Supply and replacement (including taking down) compressor carefuly of deep freezer of Capacity 285/310 Ltr (of any make) with the new compressor including necessary brazing, gas charging of suitablerefrigerant gas(enivornment friendly), testing complete all as specified and directed. Note: Purchase Vr, test certificate, warranty card shall be submitted by the contractor. |
65 | Supply and replacement of starting relay (As per sample) suitable for deep freezers cap 285/310Ltrs complete all as specified and directed. |
66 | All as per item 65 but thermostat switch. |
67 | All as per item 65 but Blower motor suitable for Deep Freezer. |
68 | M&L for replacement ofVoltage stabilizer copper bound 04 KVA to 5KVA, input voltage range90 volt to 220volt, output voltage 220 voltto 230 Volt AC ± 2% variation of voltage complete with accessories etc complete all as specified and directed. |
69 | Supply and replacement (including taking down) compressor carefuly of refrigerator of Capacity 286/310 Ltr (of any make) with the new inverter compressor including necessary brazing, gas charging with charging of suitablerefrigerant gas(enivornment friendly), testing complete all as specified and directed. Note: Purchase Vr, test certificate, warranty card shall be submitted by the contractor. |
70 | All as per Srl item No 69 above but of capacity 165/175 Ltr capacity refrigerator. |
71 | Supply and replacement (including taking down) of cooling coil assembly (as per sample), suitable for refrigerator 286/310 Ltrs capacity including necessary nuts/bolts,testing complete all as specified and directed. |
72 | All as per Srl item No 71 above but suitable for 165/175/180Ltr capacity refrigerator. |
73 | Supply and replacement (including taking down) of refrigerator filter drier (copper) of any type of refrigerator & deep Freezer (as per sample) complete all as specified and directed. |
74 | Supply and replacementof unserviceable timer for double door refrigerator(as per sample) . |
75 | All as per item 74 but biometer for double door refrigerator. |
76 | All as per item 74 but blower motor for double door refrigerator. |
77 | All as per item 74 but starting relay for refrigerator (PTCR with capacitor) |
78 | All as per item 74 but thermostate switch. |
79 | M&L for Charging of Gas R-134a suitable for summer appliancesincluding required brazing to pipe & connecting complete all as spd. (450gm gas in each can) |
80 | Repair, rewinding and maint of voltage stabilizer of any make and capacity4KVA up to 5 KVA after disconnecting the voltage stabilizer from machine, rewinding with super enamalled copper of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cut out relay, electric circuit, indicator lamp, plug top with flexible wire including neccessary painting with two coats of synthetic enamel paint (spray painting) after preparing of surfacecomplete all as specified and directed. |
81 | All as per item 80 butcapacity2KVA up to 3 KVA. |
82 | S&F in replacement (in repair) Capillery Tube suitablesize 0.31 & 0.36mm dia suitable for refrigerator & deep Freezer (as per sample)complete all as specified and directed. |
83 | S&F in replacement waste water coolertray suitablefor 40/80,60/120,150/150 ltr (as per sample) complete all as specified and directed. |
84 | M&L for Charging of Gas R-32 forhot/cold Air conditioner (at site) complete all as specified and directed |
85 | M&L for Charging of refrigerant gas 600 for refrigerator any size (180gm gas in each can) complete all as specified and directed. |
86 | M&L for Charging of gas R-410 for Air conditioner all as specified and directed |
87 | S&F in replacement of PCB circuit for inverter type refrigerator any capacity/any make (as per sample) complete all as specified and directed. |
88 | S&F in replacement gasket for top cover of water cooler, (as per sample) complete all as specified and directed. |
89 | S&F in replacement filter drier (copper) suitable for any type of water cooler all as specified and directed |
90 | S&F in replacement of condenser for Refrigerator of any capacity, any type (as per sample) complete all as specified and directed. |
91 | S&F in replacement shoessuitable for Refrigerator any cap, any type (as per sample) complete all as specified and directed. |
92 | Deduct:Total amount of Schedule "A" Section II (SCH of CREDIT) Rs 170305.00 shall be deducted from Schedule "A" (BOQ) to arriveat the Contract Sum |