Housing Urban and Rular Development Government Departments Closing in 0 days TDR #29158878

Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt. Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt.

Issued by Government Departments · Narwana, Haryana
Tender Value
5.76 Crore
Estimated cost
Bid Submission
23 Sep 2021
0 days left
EMD
11.54 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Narwana → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt. Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt.

BOQ

Name of Work: CONSTRUCTION OF FOR CONSTRUCTION OF BOYS HOSTEL BUILDING IN THE CAMPUS OF GOVT. POLYTECHNIC AT NARWANA IN JIND DISTT.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (1) All Kind of Soil. (HSR 4.12.1)
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (HSR 4.32).
3Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (HSR 4.33).
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). (HSR 6.1.2).
51:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size). (HSR 6.1.6).
61:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). (HSR 6.1.7)
720 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: (1) Vertical. (HSR 6.12.1).
8Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13).
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. (1) 1:1½:3 (1 cement : 1½ coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). (HSR 6.14.1).
10Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement: (1) 1:1½:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.15.1).
11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). (HSR 6.16).
12Centering and shuttering including strutting, propping etc. and removal of form work for: (HSR 6.29). Foundations, footings, bases for columns.(HSR 6.29.1)
13Columns, piers, abutments, pillars, posts and struts. (HSR 6.29.3).
14Centering and shuttering including strutting, propping etc. and removal of form for:- (HSR 6.30). Suspended floors, roofs, landings, balconies and access platform. (HSR 6.30.3).
15Lintels, beams, plinth beams, girders, bressumers and cantilevers. (HSR 6.30.5).
16Columns, Pillars, Piers, Abutments, Posts and Struts. (HSR 6.30.6)
17Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. (HSR 6.30.13)
18Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level.Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (6) Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.33.6)
19Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.(6) Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.34.6)
20Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning/self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it\"s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). (1) Floor Joint of 100 mm gap. (HSR 6.61.1).
21Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). (1) Wall Joint of 100 mm gap. (HSR 6.62.1).
22Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). (1) Roof Joint of 100 mm gap. (HSR 6.63.1).
23Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:(2) Cement Mortar 1:6 (1 cement : 6 coarse sand). (HSR 7.20.2).
24Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar 1:6 (1 cement : 6 coarse sand) : (2) With Modular bricks. (HSR 7.23.2).
25Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. (2) Cement mortar 1:4 (1 cement :4 coarse sand). (HSR 7.28.2).
26Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in : (2) Cement mortar 1:6 (1 cement : 6 Coarse sand). (HSR 7.47.2)
27Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (2) Granite Work. (HSR 8.27.2).
28Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : (1) With residual type petroleum bitumen of grade VG -10. (HSR 9.10.1).
2910 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (1) With common burnt clay non-modular brick tile of class designation 10. (HSR 9.11.1).
30Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (1) In 75x75 mm deep chase. (HSR9.17.1).
31Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18).
32Supplying and fixing in position 60 cm long G.I. pipe class ‘B’ spouts in chajjas and cantilevers. (5) 50 mm internal dia. (HSR 9.55.5).
33Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (9.57) (2) 110 mm diameter. (HSR 9.57.2)
34(3) 150 mm diameter. (HSR 9.57.3)
35Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (5) Bend 87.5°. (HSR 9.58.5). (2) 110 mm diameter. (HSR 9.58.5.2).
36(3) 110 mm diameter. (HSR 9.58.5.3).
37Providing and laying of base course of floors consisting of 100 mm thickcement1:8:16and100mmsandor stone filling. (HSR 10.1).
38Providing and laying of screedof50mmthickcementconcrete 1:8:16 to be laid below the topping. (HSR 10.4).
39Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. (1) 40 mm wide and 4 mm thick. (HSR 10.22.1).
40Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : (2) Medium shade pigment using 50% white cement and 50% ordinary cement. (HSR 10.26.2)
41Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : (2) Medium shades pigment using 50% white cement and 50% ordinary cement. (HSR 10.28.2)
42Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : (1) Light shade pigment using white cement. (HSR 10.29.1).
43Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : (1) 25 mm thick. (HSR 10.37.1).
44Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38).
45Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR 10.42)
46Laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (1) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (HSR 10.50.1). (LABOUR RATE ONLY). Granite Will be Supplied by the Department.
47Fixing granite stone in all shades 15mm to 18 mm thickin skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade ofGranite including labour for fixing cramps pins and dowels etc. (HSR 10.51). (LABOUR RATE ONLY). Granite Will be Supplied by the Department.
48Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58).
49Laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (2) Size of Tile 600x600 mm. (HSR 10.63.2). (LABOUR RATE ONLY). (Tile Will be Supplied by the Department.)
50Laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (2) Size of Tile 600x600 mm. (HSR 10.67.2). (LABOUR RATE ONLY). (Tile Will be Supplied by the Department.)
51Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR 10.77).
5210 mm thick cement plaster. (2) 1:3 (1 cement: 3 fine sand). (HSR 11.4.2).
5312 mm cement plaster of mix: (4) 1:6 (1 cement: 6 fine sand). (HSR 11.5.4).
5415 mm cement plaster on the rough side of single or half brick wall of mix: (2) 1:6 (1 cement: 6 fine sand). (HSR 11.6.2)
55Applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60). (LABOUR RATE ONLY)
56Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : (1) New work (two or more coats) over and including water thinnable priming coat with cement primer. (HSR 11.64.1). (LABOUR RATE ONLY)
57Applying priming coat:- With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. (HSR 11.68.3). (LABOUR RATE ONLY)
58Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76). (LABOUR RATE ONLY)
59Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77). (LABOUR RATE ONLY)
60Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78). (LABOUR RATE ONLY)
61Painting the wooden/metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade: (1) Two or more coats on new work. (HSR 11.82.1). (LABOUR RATE ONLY)
62Finishing walls with textured exterior paint of required shade : (1) New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (HSR 11.94.1). (LABOUR RATE ONLY)
63Finishing walls with Acrylic Smooth exterior paint of required shade : (1) New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). (HSR 11.95.1). (LABOUR RATE ONLY)
64Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (2) Kiln seasoned and chemically treated Hollock wood. (2) 30 mm thick. (HSR 12.10.2.2)
65Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: (2) 30 mm thick shutters. (1) with ISI marked M.S. pressed butt hinges bright finished of required size. (2) 30 mm thick. (HSR 12.19.2.1.2).
66Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (HSR 12.37). 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (HSR 12.37.1)
6725 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. (HSR 12.37.3).
68Fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (1) 150 mm. (HSR 12.60.1). (LABOUR RATE ONLY)
69Fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. (1) 150 mm. (HSR 12.64.1). (LABOUR RATE ONLY)
70Fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. (HSR 12.84). (LABOUR RATE ONLY).
71Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. (HSR 12.88).
72Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete. (HSR 12.97). 125x75x4 mm. (HSR 12.97.1)
73100x75x4 mm. (HSR 12.97.3)
74Fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. (HSR 12.98). (LABOUR RATE ONLY) Size 300 mm x 16 mm. (HSR 12.98.1)
75Size 250 mm x 16 mm. (HSR 12.98.2)
76Fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.99). (LABOUR RATE ONLY) Size 200 mm x 10 mm. (HSR 12.99.3)
77Size 150 mm x 10 mm. (HSR 12.99.4)
78Size 100 mm x 10 mm. (HSR 12.99.5)
79Fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.102). (LABOUR RATE ONLY). 125 mm (HSR 12.102.1)
80100 mm (HSR 12.102.2)
8175 mm (HSR 12.102.3)
82Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fastenersto be paid for separately) : (1) Fixed Portion. (1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). (HSR 12.157.1.1).
83Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fastenersto be paid for separately) : (2) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (1) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15). (HSR 12.157.2.1).
84Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. (2) Pre-laminated particle board with decorative lamination on both sides. (HSR 12.158.2).
85Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): (2) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm). (HSR 12.159.2).
86Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (1) With stainless steel cover plate minimum 1.25 mm thickness. (HSR 12.160.1).
87Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. (1) Anodized (AC 15) aluminium. (HSR 12.167.1).
88Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (HSR 12.170).
89Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). (1) Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)(HSR 12.176.1).
90Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (HSR 13.3). Profile B Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.1.1).
91Profile E Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.3.1).
92Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (2) 5.5 mm thick glass panes. (HSR 13.10.2).
93Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (HSR 13.29.2)
94Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41).
95Cutting holes upto 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. (HSR 20.28). 115 mm thickness of roof or floor. (HSR 20.28.2)
96150 mm thickness of roof or floor. (HSR 20.28.3)
97PUBLIC HEALTH WORK:- Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections - (6) Ferrule size 40 mm. (HSR 20.24.6).
98Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 20.25) 11.43 cm thickness of walls. (HSR 20.25.1).
9922.86 cm thickness of walls. (HSR 20.25.2).
100Labour our fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs rounds pipes including all cutting and wastage. (HSR 20.29). 15 mm internal diameter of sleeve pipe. (HSR 20.29.1).
10120 mm internal diameter of sleeve pipe. (HSR 20.29.2).
10225 mm internal diameter of sleeve pipe. (HSR 20.29.3).
10332 mm internal diameter of sleeve pipe. (HSR 20.29.4).
10440 mm internal diameter of sleeve pipe. (HSR 20.29.5).
105Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. (1) Up to 200 mm internal diametre. (HSR 20.49.1).
106Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described initem No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94). 200 mm Internal diameter. (HSR 21.94.3)
107250 mm Internal diameter. (HSR 21.94.4)
108Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot & socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described initem No. 21.38, item 21.44, item 21.45, & item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: (HSR 21.95) 350 mm dia. (HSR 21.95.1).
109400 mm dia. (HSR 21.95.2).
110Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (2) Kitchen sink without drain board. (2) 610x460 mm bowl depth 200 mm. (HSR 22.10.2.2).
111Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (1) 15 mm nominal dia. (HSR 22.12.1).
112Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (2) Flexible pipe. (1) 32 mm dia. (HSR 22.14.2.1).
113Fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15). (LABOUR RATE ONLY)
114Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint. (HSR 22.16).
115Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks. (1) With Bottle Trap (Indian make). (HSR 22.17.1).
116Fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (1) White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (HSR 22.22.1). (LABOUR RATE ONLY)
117Fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (1) One urinal basin with 5 litre white P.V.C. automatic flushing cistern. (HSR 22.25.1). (LABOUR RATE ONLY).
118Fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR 22.33). (LABOUR RATE ONLY)
119Fixing toilet paper holder : (1) C.P. brass. (HSR 22.42.1). (LABOUR RATE ONLY)
120Fixingpartitions for different type of urinals. (1) Vitreous Chinaware Partition plate. (2) Large size 835mm x 355 mm. (1) White. (HSR 22.50.1.2.1). (LABOUR RATE ONLY)
121Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. (HSR 22.53). 100 mm dia pipe. (HSR 22.53.1)
12275 mm dia pipe. (HSR 22.53.2)
123Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: (2) 100 mm inlet and 75 mm outlet. (1) Sand cast iron S&S as per IS - 3989. (HSR 22.80.2.1).
124Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (HSR 22.85). 32 mm nominal outer dia Pipes. (HSR 22.85.4)
12540 mm nominal outer dia Pipes. (HSR 22.85.5).
126Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (HSR 22.86). 15 mm nominal outer dia Pipes. (HSR 22.86.1).
12720 mm nominal outer dia Pipes. (HSR 22.86.2)
12825 mm nominal outer dia Pipes. (HSR 22.86.3).
129Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work). (HSR 22.94). 15 mm nominal bore. (HSR 22.94.1)
13020 mm nominal bore. (HSR 22.94.2)
13125 mm nominal bore. (HSR 22.94.3)
13232 mm nominal bore. (HSR 22.94.4)
13340 mm nominal bore. (HSR 22.94.5)
134Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (HSR 22.98). 25 mm nominal bore. (HSR 22.98.1)
13520 mm nominal bore. (HSR 22.98.2)
13632 mm nominal bore. (HSR 22.98.3)
13740 mm nominal bore. (HSR 22.98.4)
138Providing and fixing Unplasticised PVC connection pipe with brass unions: (2) 45 cm length. (1) 15 mm nominal bore. (HSR 22.101.2.1).
139Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (2) 150 mm diameter. (HSR 22.102.2).
140Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. (2) 20 mm nominal bore. (HSR 22.103.2).
141Fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (1) 15 mm nominal bore. (HSR 22.104.1). (LABOUR RATE ONLY)
142Fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (1) 15 mm nominal bore. (HSR 22.106.1). (LABOUR RATE ONLY)
143Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (1) 15 mm nominal bore. (HSR 22.107.1). (LABOUR RATE ONLY)
144Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (HSR 22.117). (LABOUR RATE ONLY).
145Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (2) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (HSR 22.119.2). (LABOUR RATE ONLY)
146Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : (1) 100 mm diameter S.W. pipe. (HSR 22.164.1).
147Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (1) 100x100 mm size P type. (1) With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.166.1.1).
148Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.179). Inside dimensions 455x610 mm and 45 cm deep for single pipe line : (HSR 22.179.1)
149Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets: (HSR 22.179.2)
150Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets: (HSR 22.179.3)
151Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182).
152Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (HSR 22.190) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.1.1).
153Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.2.1).
154Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.3.1).
155Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg. (HSR 22.202).
156Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : (1) With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.205.1).
157Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209).
158Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (HSR 22.211).
159Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. (1) C.P Brass. (2) Two Way. (HSR 22.212.1.2).
160Providing and fixing PTMT pillar cock of approved quality and colour. (1) 15 mm nominal bore, 107 mm long, weighing not less than 110 gms. (HSR 22.213.1).
161Fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. (2) Size 550 mm x 400 mm x 815 mm. (HSR 22.221.2). (LABOUR RATE ONLY)
162Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (2) Single Socket Type B. (2) 110mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222). 110mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222.2.2).
16375mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222.2.4).

AI Tender Summary

OUR REF NO 29158878
AUTHORITY Government Departments
TENDER VALUE 5.76 Crore
LAST DATE 23-09-2021
Authority
Authority Name Public Works Department
Work Description Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt. Construction Of Boys Hostel Building In The Campus Of Govt. Polytechnic At Narwana In Jind Distt.
Basic Detail
Tender No Boys Hostel
Bidding Type Tender
Location
City Narwana
State Haryana
Key Dates
Publish Date 10 Sep 2021
Submission Date 23 Sep 2021
Open Date 24 Sep 2021
Finance
Tender Value 5.76 Crore
Tender Fee 20000
EMD 11.54 Lakhs
Exemption Not Available
Document List
f565e2f7-45ea-4a60-ae36-1f8fc35dc843.html
BOQ_247268.xls
DNIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 24, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f565e2f7-45ea-4a60-ae36-1f8fc35dc843.html

xls

BOQ_247268.xls

pdf

DNIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders