Tender For Ht / Lt And Sub Station Works In Doda District Under Pmdp-R-Rural Electrification Works Of Doda District In Jammu Province Under Pmdp ( Rural ) - 1 66 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Change, DODA DISTRICT-Jammu And Kashmir

Power Development Department has published Tender For Ht / Lt And Sub Station Works In Doda District Under Pmdp-R-Rural Electrification Works Of Doda District In Jammu Province Under Pmdp ( Rural ) - 1 66 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Change. Submission Date for this Tender is 14-10-2021. Coats and Jackets Tenders in DODA DISTRICT Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29158336
Corrigendum : Tender For Ht / Lt And Sub Station Works In Doda District Under Pmdp-R-Rural Electrification Works Of Doda District In Jammu Province Under Pmdp ( Rural ) - 1 66 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Change
Open Tender
Indian
Jammu And Kashmir
DODA DISTRICT
14-10-2021

Tender Details

Tender For Ht / Lt And Sub Station Works In Doda District Under Pmdp-R-Rural Electrification Works Of Doda District In Jammu Province Under Pmdp ( Rural ) - 1 66 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 2 66 / 11 Kv, 6.3 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 3 66 / 11 Kv, 8 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 4 33 / 11 Kv, 8 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 5 33 / 11 Kv, 10 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 6 33 / 11 Kv, 3.15 Mva, 3 Phase Power Transformer, Copper Winding, Off-Load Tap Changer With Ht And Lt Connectors 7 33 / 11 Kv, 6.3 Mva, 3 Phase Power Transformer, Copper Winding, On-Load Tap Changer With Ht And Lt Connectors 8 66 Kv, 1250Amp, 31.5 Ka Sf6 Circuit Breaker 9 Control & Relay Panel For Protection Of 66 / 11 Kv Power Transformerwith Differential Relay ( Scada Compatible ) 10 Control & Relay Panel For Protection Of 66 / 11 Kv Power Transformer Without Differentialrelay ( Scada Compatible ) 11 Control & Relay Panel For 66 Kv Feeder Vcb ( Scada Compatible ) 12 66 Kv, Multi Ratio , Multi Core , Single Phase Current Transformer 13 66 Kv, Multi Ratio , Multi Core , Voltage Transformer 14 66 Kv Lightening Arrestors 15 66 Kv, 800 A Isolator With Earthing Blade 16 66 Kv, 800 A, Isolator Without Earthing Blade 17 66 Kv Post Insulator 18 Disc Insulators For 66 Kv Line Bay 19 33 Kv Disc Insulators Complete With Fitting 20 Control & Relay Panel For Protection Of 33 / 11 Kv Power Transformerwith Differential Relay ( Scada Compatible ) 21 Control & Relay Panel For Protection Of 33 / 11 Kv Power Transformerwithout Differential Relay ( Scada Compatible ) 22 33 Kv, 1250 Amp, 25 Ka For 3 Sec, Outdoor Vacuum Circuit Breaker 23 33 Kv, 25 Ka For 3 Sec, Voltage Transformer, 33 / 0.11 Kv 24 33 Kv, 25 Ka For 3 Sec, Single Phase Current Transformer 25 Control & Relay Panel For 33 Kv Feeder Vcb ( Scada Compatible ) 26 33 Kv, 800 A, Isolator With Earthing Blade 27 33 Kv, 800 A, Isolator Without Earthing Blade 28 30 Kv Lightening Arrestors 29 2 Core 2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 30 4 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 31 6 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 32 12 Core2.5Sqmm Frls Type Cu. Control Cable, Pvc Insulated Armoured Including Lugs, Ferrules Etc. 33 30 V Battery Bank , 100 Ah, Of 15 No. Cells Of 2V Each, Sealed Maintaince Free Vrla Type , High Impact Polyprophelene Coplymer Conatiner , Flame Retardant ( For New 66 / 11 Kv Substation ) 34 30V, 100 Ah, Float-Cum Booster Charger , With Full Wave Rectification For 220 V, 1 Phase , 50Hz Ac Input Supply. 35 Construction Of Rcc Foundation For Power Transformersincuding Guide Rail, Considering Original Equipment Manufacturer Recommendations Includingshuttering And By Providing Reinforcement, Cement Concreting In 1:1.5:3, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. 36 66 Kv / 33Kv Yard Concreting / Metalling For New Substation ) Providing, Supplying And Laying 100Mm Thick Pcc ( 1:4:8 ) Using 20Mm Nominal Coarse Aggregates And Spreading 100Mm Thick Layer Of 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Over The Pcc Including Construction Of Toe Wall ( Exposed Wall Plastered With Cement Mortar 1:5 ) To Hold 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Wherever Required In The Bays Covered Under The Present Scope As Detailed In The Gelo As Per Technical Specification, Approved Drawing & Scope Of Works. & Instructions Of Engineer-In Charge. 37 66 Kv / 33Kv Yard Concreting / Metalling For Addl Transformer Substation ) Providing, Supplying And Laying 100Mm Thick Pcc ( 1:4:8 ) Using 20Mm Nominal Coarse Aggregates And Spreading 100Mm Thick Layer Of 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Over The Pcc Including Construction Of Toe Wall ( Exposed Wall Plastered With Cement Mortar 1:5 ) To Hold 20Mm Single Size Uncrushed / Crushed / Broken Stone Pebbles Wherever Required In The Bays Covered Under The Present Scope As Detailed In The Gelo As Per Technical Specification, Approved Drawing & Scope Of Works. & Instructions Of Engineer-In Charge. 38 Construction Of Rcc Foundation For Outdoor Mounted 66 Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. 39 Construction Of Rcc Foundation For 33 Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. 40 Construction Of Rcc Foundation For 33Kv Gantry Structures & Other Equipments Considering Original Equipment Manufacturer Recommendations Including Excavation Of Pit, Shuttering And By Providing Reinforcement, Cement Concreting, Painting Etc As Per Technical Specification, Approved Drawings & Scope Of Works. Works Also Includes Providing Working Platform For Operation Of Breakers And Painting. ( For Additional X-Mer ) 41 Chainlink Fencing Of 66 Kv / 33Kv Yard Of Substation By Way Of Mass Concrete In Foundationsandchainlink Fencing Of 6 Ft Height ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) 42 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 820 Mm ) 43 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 750 Mm ) 44 Cable Trench For Laying Of 11 Kv Xlpe Cables, Control Cables From Switchyard To Control Room ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) ( Inner Width 500 Mm ) 45 Compound Walling Of Identified Landby Way Of Mass Concrete In Foundationsand228 Mm Brick Wall Of 2 M Height ( For New 66 / 11 Kv Or 33 / 11 Kv Substation ) With Provision Of Double Beam. 46 Design, Engineering & Construction Of Control Room Building For New 33 / 11 & 66 / 11 Kv Receiving Substation ( 13Mx8.5M C / C ) Consisting Of Rcc Slab Including Indoor Trenches, Comprising Of Battery Room, Panel Room, Store Room, Administration Room, Toilet Etc As Required Of Overall Building Sizeas Per Electrical Requirement / Approved Drawing , Single Story Including All Internal Services Like Water Supply, Sewerage System, Finishing, Plinth Protection, Including Supply Of Construction Materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation Etc, Complete In All Resect Including , Internal Wiring, Water Proofing And Roof Projections Of 600X600mm As Per Detailed Technical Specification, Approved Drawings & Scope Of Works. 47 Development Of Land By Removing Weeds, Wild Grass, Levelling And Endulation If Any, Ornamental Land Scaping And Growing Of Ornamental Trees In Unbuilt Areas And Road Sides And Development Of Roads Along With Surface Drains And Station Fgl. 48 Borewell With Submersible Pump ( At New Receiving Substation ) 49 Earthing Mat With Gi Flat 50X8 ( For New Receiving Substation ) With 50X6 Risers. 50 Design, Engineering & Construction Ofshift Quarters For Je And Sba At New 66 / 11 & 33 / 11 Kv Substation As Per Instruction Of Engineer-In-Charge Complete In All Resect As Per Detailed Technical Specification, Approved Drawings & Scope Of Works 51 Retaining Wall ( Rcc Type ) 52 Retaining Wall ( Stone Masonry Type ) 53 Soil Filling For New / Additional Substations 54 Earthing Electrode ( 3M Long 40Mm Dia Gi Pipe ) Foradd. Receiving Substation Earth Mat 55 Yard Lighting Of The New Receiving Sub Station Using 4 No , 12 Meter Long, Gi High Mast Poles , Continuously Tapered Of Octagonal Ofcross-Section ; Including Suitable Shallow Raft Foundation Using8 Nos 250 Watt Non Integral Flood Light Luminaire With Single Piece Die Cast Aluminum Housing And Pot Optic Reflector And Toughened Glass Cover, Conforming To Ip-66 Complete With All Accessories And Suitable Control Feeder Panel. 56 Earth Mat With Gi Flat 50X8 & 50X6 Risers For Additional Power Transformer 57 Earthing Of Augmented Power Transformer 58 D.C Distribution Board With Distributional Panel ( 30V, Dc ) With 1 No. Amp Ckt. Breaker ( For 66 / 11 Kv Newsubstations ) 59 A.C Distribution Boardwith Distribution Panel ( 415 V, Ac ) Complete With Ckt .Breaker , Including Lamp Etc ( For 66 / 11 Kv New Substations ) 60 Fire Fighting Equipment ( For 66 / 11 Kv Newsubstations ) A ) . Dry Chemical Powder Type ( 6Kg ) Forcontrol Room -3No. B. ) Co2 Type Of 4.5 Kg Capacity For Control Room- 4No. C ) .Co2 Type Trolly Mounted Of 22.5Kg Capacity For Switch Yard 2No. 61 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 3 Outgoing Panel ) ( Scada Compatible ) 62 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 4 Outgoing Panel ) ( Scada Compatible ) 63 11 Kv, 1250 Amp, 25 Ka For 3 Sec, Vcb Switchgear Panel Board ( 1 Incomer Panel + 5 Outgoing Panel ) ( Scada Compatible ) 64 11 Kv Isolator Double Break 3 Pole , 600 A With Earth Switch 65 11 Kv L.Afor ( 66 / 11 Kv S / S, 33 / 11 Kv S / S & For Dtr Structure ) ( 10 Ka Stn Type. ) 66 100 Kva, 11 / 0.4 Kv Stn. Transformer, Aluminium Winding, With Bimetallic Terminal Connectors, Energy Efficiency Level-Ii As Per Is: 1180 ( Part-I ) : 2014 For ( New 33 / 11 Kv & 66 / 11 Kv S / S ) 67 11 Kv Xple Power Cables- 3C 120 Mm² 68 11 Kv Xple Power Cables- 3C 185 Mm² 69 11 Kv Xple Power Cables- 3C 300 Mm² 70 11 Kv Xple Power Cables- 3C 400 Mm² 71 11 Kv Xple Power Cables- Single Core 630 Sq Mm ( With One Spare Length ) 72 Indoor Type Cable Termination Kit For 11 Kv 3C 120 Mm² Xlpe Cable 73 Indoor Type Cable Termination Kit For 11 Kv 3C 185 Mm² Xlpe Cable 74 Indoor Type Cable Termination Kit For 11 Kv 3C 300 Mm² Xlpe Cable 75 Indoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable 76 Indoor Type Cable Termination Kit For Single Core 630 Sq Mm Cable 77 0Utdoor Type Cable Termination Kit For 11 Kv 3C 120 Mm² Xlpe Cable 78 Outdoor Type Cable Termination Kit For 11 Kv 3C 185 Mm² Xlpe Cable 79 Outdoor Type Cable Termination Kit For 11 Kv 3C 300 Mm² Xlpe Cable 80 Outdoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable 81 Outdoor Type Cable Termination Kit For Single Core 630 Sq Mm Cable 82 Disc Insulators For 33 Kv Line Bay 83 Single Tension Fittings For Panther Conductor 84 50 Mm² Lt Ab Cable ( 3X50+1X16+1X35 Mm² ) 85 70 Mm² Lt Ab Cable ( 3X70+1X16+1X50 Mm² ) 86 120 Mm² Lt Ab Cable ( 3X120+1X16+1X95 Mm² ) 87 35 Mm² Ht Ab Cable ( 3X35+1X70 Mm² ) 88 50 Mm² Ht Ab Cable ( 3X50+1X70 Mm² ) 89 70 Mm² Ht Ab Cable ( 3X70+1X95 Mm² ) 90 120 Mm² Ht Ab Cable ( 3X120+1X95 Mm² ) 91 Insulating Piercing Connetors 92 200 Sqmm Acsr Panther Conductor 93 150 Sqmm Acsrwolf Conductor 94 100 Sqmm Acsrdog Conductor 95 50 Sqmm Acsrrabbit Conductor 96 30 Sqmm Acsr Weasel Conductor 97 11 / 0.433 Kv, 630 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 98 11 / 0.433 Kv, 400 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 99 11 / 0.433 Kv, 250 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 100 11 / 0.433 Kv, 63 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 101 11 / 0.433 Kv, 100 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 102 11 / 0.433 Kv, 25 Kva, 3-Phase Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound Upto 200Kva, Copper Woundfor 250Kva Or Higher Kva Ratings ) 103 120 Mm² Lt4core Pvc Cable 104 400 Mm² Single Core Xlpe Cable ( 1100 V ) 105 240 Mm² Single Core Xlpe Cable ( 1100 V ) 106 185 Mm² Single Core Xlpe Cable ( 1100 V ) 107 150 Mm² Single Core Xlpe Cable ( 1100 V ) 108 120 Mm² Single Core Xlpe Cable ( 1100 V ) 109 95 Mm² Single Core Xlpe Cable ( 1100 V ) 110 70 Mm² Single Core Xlpe Cable ( 1100 V ) 111 50 Mm² Single Core Xlpe Cable ( 1100 V ) 112 25 Mm² Single Core Xlpe Cable ( 1100 V ) 113 33 Kv Pin Insulators With Pin 114 11Kv Pin Insulators With Pin 115 11Kv Go, Ab Switch 200 Amp 116 11Kv Disc Insulators Complete With Fitting 117 11 Kv Do Fuse 100 A 118 33 Kv Post Insulator 119 20 Mm Dia Stay Set Complete With Stay Wire 7 / 4 Mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy Grip, Thimbles Etc 120 16 Mm Dia Stay Set Complete With Stay Wire 7 / 3.15 Mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy Grip, Thimbles Etc. 121 Grouting Of Stay Set As Per Td / Approved Drawings 122 66 Kv Disc Insulators Complete With Fitting ( 11 Kv * 6Nos. = 01 No. ( 66 Kv ) ) 123 Suspension Fitting For Wolf Conductor ( 66 Kv Line ) 124 Earthing Of Poles & Fittings By Gi Earthing Rod 20X2500 Mm & 6 Swg Gi Wire 125 Tension Fitting For Wolf Conductor 126 8 Mtr.Long Pccpolewl-250 Kg 127 11 Mtr. Long Pcc Pole Wl- 360 Kg 128 9 Mtr. Long Pccpolewl-300 Kg 129 16 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -80 ( Is 2713, Pt I, Ii, Iii 1980. ) 130 13 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -69 ( Is 2713, Pt I, Ii, Iii 1980. ) 131 11 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -56 ( Is 2713, Pt I, Ii, Iii 1980. ) 132 8 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -15 ( Is 2713, Pt I, Ii, Iii 1980. ) 133 9 Mtr. Long Steel Tubular Polewith Welded Steel Base Plate Of Designation 410 Sp -33 ( Is 2713, Pt I, Ii, Iii 1980. ) 134 Stone Pad For Pcc Poles ( 400X400x75 ) 135 Aluminium Jointing Sleeves 136 Aluminium Paint 137 Red Oxide 138 Anti-Climbing Device With Clamps 139 Cement Concrete Foundation Of St Poles Using Cement Concreting , 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Approved Drawings ( Tentative 0.45 Cum / Pole ) 140 66 Kv Danger Plates With Clamps 141 33 Kv Danger Plates With Clamps 142 11Kv Danger Plates With Clamps 143 440 V Danger Plates With Clamps 144 Dlms Type Meter For Dt Metering With Modem 145 Meter Box With Resin Cast Ring Type Cts For Dt Metering 146 Earthing Lt Pole ( Gi Earthing Spike Made Of 20Mm Solid Rod Or 8 Swg Earthing Coil ) 147 Earthing Of Distribution Transformer - Pipe Earthing. 148 11 Kv Outgoing Feeders- Pipe Earthing.With Gi Strip 149 25Mm Dia Gi Rod 3 M Long For Earth Mat 150 Earth Wire ( 7 / 4.00 Sqmm ) 151 Eye Bolts For Guard Netting 152 Gi Wire 6 Swg, 8 Swg As Per Requirement For Guard Netting 153 Galvanised Steel Structures / Gi Channel X-Arm And Gi V-Cross Armincluding Clamps And Braces / Gi Channels / Angle / Flats Of Sizes. 154 Galvanized Nuts & Bolts 155 Gi Barbed Wire For Anti Climbing With Clamps ( 35 Turns / Pole ) 156 Gi Flat For Earthing 50X6 Mm ( For Earthing Risers For 33 Kv Bay ) 157 Gi Strip 25X3 Mm For Earthing Of Dtr, 158 Gi U-Clamps For Shackle Insulators 159 Lt Distribution Box With Mounting Clamps For 25 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 160 Lt Distribution Box With Mounting Clamps For 63 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 161 Lt Distribution Box With Mounting Clamps For 100 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 162 Lt Distribution Box With Mounting Clamps For 250 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 163 Lt Distribution Box With Mounting Clamps For 400 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 164 Lt Distribution Box With Mounting Clamps For 630 Kva Dtr With Mccbs With Suitable Incoming And Outgoing Ckts 165 Transformer Pad ( For 400 Kva & 630 Kva Dtrs ) 166 Lt Line Spacers 167 Mccb - 200 Amps ( With Enclosure And Pole Mounting Arrangement ) For 100 Kva, 11 / 0.4 Kv Station Transformer 168 Pg Clamps For 200 Mm² Acsr Conductor 169 Pg Clamps For 150 Mm² Acsr Conductor 170 Pg Clamps For 100 Mm² Acsr Conductor 171 Pg Clamps For 30 Mm² Acsr Conductor 172 Pg Clamps For 50 Mm² Acsr Conductor 173 Pg For Lt Ab Cable 174 Shackle Insulators With Pin 175 Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape, Droppers Etc. 176 Suspension / Tension Clamp With Eye Hook 177 T Clamps For Panther Conductor 178 Wedge Connectors / Pg Clamps 179 Straight Through For Lt Ab Cable Joining Kit 180 Soil Cutting 181 Approach Road To The Substation Land If Required 182 Lt 3 Phase Pole Distribution Box With Busbar Lt Service Connection 183 35 Sqmm 4C Pvc Cable 184 Safety And Operation Instrument 185 Provision For Bus- Bar & 11 Kv Supporting Structures ( For Aug Transformers ) 186 Heat Shrinkable Outdoor Cable Termination Kit 187 Mid Span Straight Through Jointing Kit For 11 Kv Abc 188 New / Replacement 66Kv Sf6 For R&M66 / 11 Kv S / S 189 New / Replacement 33Kv Vcbs For R&M33 / 11 Kv S / S 190 New 66Kv C& R Panels For R&M66 / 11 Kv S / S ( Scada Compatible ) 191 New 33Kv C& R Panels For R&M33 / 11 Kv S / S ( Scada Compatible ) 192 New / Replacement Of 66 Kv Lasfor R&M66 / 11 Kv S / S 193 New / Replacement Of 33 Kv Lasfor R&M33 / 11 Kv S / S 194 New / Replacement Of 66 Kv Ctsfor R&M66 / 11 Kv S / S 195 New / Replacement Of 33 Kv Ctsfor R&M33 / 11 Kv S / S 196 New / Replacement Of 66 Kvptsfor R&M66 / 11 Kv S / S 197 New / Replacement Of 33 Kvptsfor R&M33 / 11 Kv S / S 198 New / Replacement Of 66 Kv Isolatorwith Earthing Bladefor R&M66 / 11 Kv S / S 199 New / Replacement Of 33 Kv Isolatorwith Earthing Bladefor R&M33 / 11 Kv S / S 200 New / Replacement Of 66 Kv Isolatorwithout Earthing Blade For R&M66 / 11 Kv S / S 201 New / Replacement Of 33 Kv Isolatorwithout Earthing Blade For R&M33 / 11 Kv S / S 202 Indoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 66 / 11 Kv S / S 203 Indoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 33 / 11 Kv S / S 204 Outdoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 66 / 11 Kv S / S 205 Outdoor Type Cable Termination Kit For 11 Kv 3C 400 Mm² Xlpe Cable For R&M 33 / 11 Kv S / S 206 11Kvgo Switich For R&M66 / 11 Kv S / S 207 11Kvgo Switich For R&M33 / 11 Kv S / S 208 11Kv La Setsfor R&M66 / 11 Kv S / S 209 11Kv La Setsfor R&M33 / 11 Kv S / S 210 Battery Bankfor R&M66 / 11 Kv S / S 211 Battery Bankfor R&M33 / 11 Kv S / S 212 Battery Chargerfor R&M66 / 11 Kv S / S 213 Battery Chargerfor R&M33 / 11 Kv S / S 214 Fire Extinguisher Systemfor R&M66 / 11 Kv S / S 215 Fire Extinguisher Systemfor R&M33 / 11 Kv S / S 216 Powercable 11Kv 400Sqmm For R&M33 / 11 Kv S / S 217 Powercable 11Kv 400Sqmm For R&M66 / 11 Kv S / S 218 Acdbfor R&M33 / 11 Kv S / S 219 Acdbfor R&M66 / 11 Kv S / S 220 Dcdbfor R&M33 / 11 Kv S / S 221 Dcdbfor R&M66 / 11 Kv S / S 222 11 Kv Vcb Switchgear Panel Board ( Scada Compatible ) ( 1 Incomer Panel + 4 Outgoing Panel ) For R&M 66 / 11 Kv S / S 223 11 Kv Vcb Switchgear Panel Board ( Scada Compatible ) ( 1 Incomer Panel + 4 Outgoing Panel ) For R&M 33 / 11 Kv S / S

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Sep-2021 CORRIGENDUM1 Other 11-10-2021
2 04-Oct-2021 CORRIGENDUM 2 Financial Bid 11-10-2021
3 08-Oct-2021 CORRIGENDUM 3 Date 14-10-2021
4 08-Oct-2021 CORRIGENDUM 4 Other 14-10-2021
5 13-Oct-2021 CORRIGENDUM 5 Financial Bid 14-10-2021

Key Value

Document Fees
INR 25000 /-
EMD
Refer document
Tender Value
INR 23.57 Crore /-

BOQ Items

Name of Work:Rural Electrification works of Doda District in Jammu Province Under PMDP (Rural)
Sl. No. Item Description
166/11 kV, 10 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
266/11 kV, 6.3 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
366/11 kV, 8 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
433/11 kV, 8 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
533/11 kV, 10 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
633/11 kV, 3.15 MVA,3 Phase Power Transformer,Copper winding, Off-load tap changer with HT and LT connectors
733/11 kV, 6.3 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors
866 kV, 1250Amp, 31.5 kA SF6 Circuit Breaker
9Control & Relay Panel for protection of 66/11 kV Power Transformerwith differential Relay (SCADA Compatible)
10Control & Relay Panel for protection of 66/11 kV Power Transformer without differentialrelay (SCADA Compatible)
11Control & Relay Panel for 66 kV Feeder VCB (SCADA Compatible)
1266 kV, Multi Ratio , Multi Core , Single Phase Current Transformer
1366 kV, Multi Ratio ,Multi Core , Voltage Transformer
1466 kV Lightening Arrestors
1566 kV, 800 A Isolator with Earthing Blade
1666 kV, 800 A, Isolator without Earthing Blade
1766 kV Post Insulator
18Disc Insulators for 66 KV Line Bay
1933 KV Disc Insulators complete with fitting
20Control & Relay Panel for protection of 33/11 kV Power Transformerwith differential relay (SCADA Compatible)
21Control & Relay Panel for protection of 33/11 kV Power Transformerwithout differential relay (SCADA Compatible)
2233 kV, 1250 Amp, 25 kA for 3 sec, Outdoor Vacuum Circuit Breaker
2333 kV, 25 kA for 3 sec, Voltage Transformer, 33/0.11 kV
2433 kV, 25 kA for 3 sec, Single Phase Current Transformer
25Control & Relay Panel for 33 kV Feeder VCB (SCADA Compatible)
2633 kV, 800 A, Isolator with Earthing Blade
2733 kV, 800 A, Isolator without Earthing Blade
2830 kV Lightening Arrestors
292 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
304 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
316 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
3212 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
3330 V Battery Bank ,100 AH,of 15 No. cells of 2V each,sealed maintaince free VRLA type ,high Impact polyprophelene coplymer conatiner ,flame retardant(for new 66/11 KV Substation)
3430V, 100 AH,Float-cum booster charger ,with Full wave rectification for 220 V, 1 Phase , 50hz AC Input Supply.
35Construction of RCC foundation for Power Transformersincuding guide rail, considering original equipment manufacturer recommendations includingshuttering and by providing reinforcement, cement concreting in 1:1.5:3,painting etc as per Technical Specification, approved Drawings & Scope of works.
3666 kV/33KV Yard Concreting/Metalling for new Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge.
3766 kV/33KV Yard Concreting/Metalling for addl Transformer Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge.
38Construction of RCC foundation for outdoor mounted 66 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting.
39Construction of RCC foundation for 33 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting.
40Construction of RCC foundation for 33KV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. (for additional X-MER)
41Chainlink Fencing of 66 kV/33KV Yard of Substation by way of Mass Concrete in Foundationsandchainlink fencing of 6 ft height (for new 66/11 KV or 33/11 KV Substation)
42Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 820 mm)
43Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 750 mm)
44Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 500 mm)
45Compound walling of identified landby way of Mass Concrete in Foundationsand228 mm Brick Wall of 2 M height (for new 66/11 kV or 33/11 kV Substation) with provision of double beam.
46Design, engineering & construction of Control Room Building for new 33/11 & 66/11 kV receiving substation (13mX8.5m c/c) consisting of RCC Slab including indoor trenches, comprising of battery room, panel room, store room, administration room, toilet etc as required of overall building sizeas per electrical requirement/ approved drawing ,single story including all internal services like water supply, Sewerage system, Finishing, Plinth Protection, including supply of construction materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation etc, complete in all resect including , Internal wiring, water proofing and roof projections of 600x600mm as per detailed Technical Specification, approved Drawings & Scope of works.
47Development of land by removing weeds, wild grass, levelling and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains and station FGL.
48Borewell with submersible pump (at new receiving substation)
49Earthing Mat with GI Flat 50x8 (for new receiving substation) with 50X6 risers.
50Design, engineering & construction ofShift Quarters for JE and SBA at new 66/11 & 33/11 KV Substation as per instruction of Engineer-in-charge complete in all resect as per detailed Technical Specification, approved Drawings & Scope of works
51Retaining Wall(RCC type)
52Retaining Wall (Stone masonry type)
53Soil Filling for new/additional substations
54Earthing Electrode (3m long 40mm dia GI pipe) forAdd. Receiving Substation Earth Mat
55Yard Lighting of the new receiving sub station using 4 no , 12 meter long, GI High Mast poles ,continuously tapered of octagonal ofcross-section ; including suitable shallow raft foundation using8 nos 250 watt non integral flood light luminaire with single piece die cast aluminum housing and pot optic reflector and toughened glass cover, conforming to IP-66 complete with all accessories and suitable control feeder panel.
56Earth Mat with GI Flat 50X8 & 50X6 risers for Additional Power Transformer
57Earthing of Augmented Power Transformer
58D.C Distribution Board with distributional Panel( 30V, DC) with 1 No. Amp Ckt. Breaker (for 66/11 kV newSubstations)
59A.C Distribution Boardwith distribution panel (415 V,AC) complete with Ckt .breaker ,including Lamp etc (for 66/11 kV new Substations)
60Fire Fighting Equipment (for 66/11 kV newSubstations) a). Dry Chemical powder type(6kg) forcontrol room -3No. b.) CO2 type of 4.5 kg Capacity for Control room- 4No. c).CO2 type trolly mounted of 22.5kg capacity for switch yard 2No.
6111 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 3 Outgoing Panel) (SCADA Compatible)
6211 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 4 Outgoing Panel) (SCADA Compatible)
6311 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 5 Outgoing Panel) (SCADA Compatible)
6411 kv Isolator double break 3 pole ,600 A with Earth switch
6511 kV L.Afor (66/11 kv S /s, 33/11 KV s/s & for DTR structure ) (10 kA Stn type.)
66100 KVA, 11/0.4 KV Stn. Transformer, Aluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014 for (New 33/11 kV & 66/11 kV S/s)
6711 KV XPLE Power Cables- 3C 120 mm²
6811 KV XPLE Power Cables- 3C 185 mm²
6911 KV XPLE Power Cables- 3C 300 mm²
7011 KV XPLE Power Cables- 3C 400 mm²
7111 KV XPLE Power Cables- Single Core 630 sq mm (With one spare length)
72Indoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable
73Indoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable
74Indoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable
75Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable
76Indoor Type Cable Termination Kit for Single core 630 sq mm Cable
770utdoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable
78Outdoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable
79Outdoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable
80Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable
81Outdoor Type Cable Termination Kit for Single core 630 sq mm Cable
82Disc Insulators for 33 KV Line Bay
83Single Tension Fittings for Panther Conductor
8450 mm² LT AB Cable (3X50+1x16+1X35 mm²)
8570 mm² LT AB Cable (3X70+1x16+1X50 mm²)
86120 mm² LT AB Cable (3X120+1x16+1X95 mm²)
8735 mm² HT AB Cable (3X35+1X70 mm²)
8850 mm² HT AB Cable (3X50+1X70 mm²)
8970 mm² HT AB Cable (3X70+1X95 mm²)
90120 mm² HT AB Cable (3X120+1X95 mm²)
91Insulating Piercing Connetors
92200 sqmm ACSR Panther Conductor
93150 sqmm ACSRWolf Conductor
94100 sqmm ACSRDog Conductor
9550 sqmm ACSRRabbit Conductor
9630 sqmm ACSR Weasel Conductor
9711/0.433 kV, 630 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
9811/0.433 kV, 400 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
9911/0.433 kV, 250 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
10011/0.433 kV, 63 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
10111/0.433 kV, 100 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
10211/0.433 kV, 25 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
103120 mm² LT4Core PVC Cable
104400 mm² Single Core XLPE Cable (1100 V)
105240 mm² Single Core XLPE Cable (1100 V)
106185 mm² Single Core XLPE Cable (1100 V)
107150 mm² Single Core XLPE Cable (1100 V)
108120 mm² Single Core XLPE Cable (1100 V)
10995 mm² Single Core XLPE Cable (1100 V)
11070 mm² Single Core XLPE Cable (1100 V)
11150 mm² Single Core XLPE Cable (1100 V)
11225 mm² Single Core XLPE Cable (1100 V)
11333 kV Pin Insulators with Pin
11411kV Pin Insulators with Pin
11511KV GO, AB Switch 200 Amp
11611kV Disc Insulators complete with fitting
11711 kV DO FUSE 100 A
11833 kV Post Insulator
11920 mm dia Stay Set complete with Stay Wire 7/4 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc
12016 mm dia Stay Set complete with Stay Wire 7/3.15 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc.
121Grouting of Stay Set as per TD/approved drawings
12266 kV Disc Insulators Complete with fitting (11 kV * 6nos. = 01 no. (66 kV))
123Suspension fitting for Wolf Conductor(66 kV Line)
124Earthing of Poles & fittings by GI earthing Rod 20x2500 mm & 6 SWG GI wire
125Tension Fitting for Wolf Conductor
1268 Mtr.Long PCCPoleWL-250 Kg
12711 Mtr. Long PCC Pole WL- 360 kg
1289 Mtr. Long PCCPoleWL-300 Kg
12916 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -80(IS 2713, Pt I, II, III 1980.)
13013 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -69 (IS 2713, Pt I, II, III 1980.)
13111 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -56 (IS 2713, Pt I, II, III 1980.)
1328 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -15 (IS 2713, Pt I, II, III 1980.)
1339 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -33(IS 2713, Pt I, II, III 1980.)
134Stone Pad for PCC poles (400x400x75)
135Aluminium Jointing Sleeves
136Aluminium Paint
137Red Oxide
138Anti-Climbing Device with Clamps
139Cement concrete foundation of ST Poles using cement concreting , 1 part cement, 2 part sand,4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings (Tentative 0.45 cum/pole)
14066 kV Danger Plates with Clamps
14133 kV Danger Plates with Clamps
14211kV Danger Plates with Clamps
143440 V Danger Plates with Clamps
144DLMS type Meter for DT Metering with Modem
145Meter Box with Resin Cast Ring type CTs for DT Metering
146Earthing LT Pole ( GI Earthing spike made of 20mm solid rod or 8 SWG earthing coil)
147Earthing of Distribution Transformer - Pipe earthing.
14811 kV Outgoing feeders- Pipe earthing.with GI strip
14925mm dia GI Rod 3 M long for earth mat
150Earth wire (7/4.00 sqmm)
151Eye Bolts for guard netting
152GI Wire 6 SWG, 8 SWG as per requirement for guard netting
153Galvanised Steel Structures /GI Channel X-arm and GI V-cross armincluding clamps and braces/GI Channels/Angle/ Flats of sizes.
154Galvanized Nuts & Bolts
155GI Barbed Wire for Anti Climbing with clamps (35 turns / pole)
156GI flat for earthing 50x6 mm (for earthing risers for 33 kV Bay)
157GI Strip 25x3 mm for earthing of DTR,
158GI U-Clamps for Shackle Insulators
159LT Distribution Box with mounting clamps for 25 KVA DTR with MCCBs with suitable incoming and outgoing ckts
160LT Distribution Box with mounting clamps for 63 KVA DTR with MCCBs with suitable incoming and outgoing ckts
161LT Distribution Box with mounting clamps for 100 KVA DTR with MCCBs with suitable incoming and outgoing ckts
162LT Distribution Box with mounting clamps for 250 KVA DTR with MCCBs with suitable incoming and outgoing ckts
163LT Distribution Box with mounting clamps for 400 KVA DTR with MCCBs with suitable incoming and outgoing ckts
164LT Distribution Box with mounting clamps for 630 KVA DTR with MCCBs with suitable incoming and outgoing ckts
165Transformer Pad (for 400 kVA & 630 kVA DTRs)
166LT Line Spacers
167MCCB - 200 Amps (with Enclosure and pole mounting arrangement) for 100 kVA, 11/0.4 kV station Transformer
168PG Clamps for 200 mm² ACSR Conductor
169PG Clamps for 150 mm² ACSR Conductor
170PG Clamps for 100 mm² ACSR Conductor
171PG Clamps for 30 mm² ACSR Conductor
172PG Clamps for 50 mm² ACSR Conductor
173PG for LT AB Cable
174Shackle Insulators with Pin
175Sundry items like aluminium lugs, Jumpers, binding Tape, Droppers etc.
176Suspension/Tension Clamp with eye hook
177T Clamps for Panther Conductor
178Wedge Connectors / PG Clamps
179Straight Through for LT AB Cable Joining Kit
180Soil Cutting
181Approach Road to the substation land if required
182LT 3 phase pole Distribution box with busbar LT service connection
18335 sqmm 4C PVC Cable
184Safety and operation instrument
185Provision for Bus- bar & 11 kV supporting Structures (for Aug Transformers)
186Heat Shrinkable Outdoor Cable Termination Kit
187Mid Span Straight Through Jointing Kit for 11 KV ABC
188New /Replacement 66kV SF6 for R&M66/11 kv s/s
189New /Replacement 33kV VCBs for R&M33/11 kv s/s
190New 66kV C& R Panels for R&M66/11 kv s/s (Scada Compatible)
191New 33kV C& R Panels for R&M33/11 kv s/s (Scada Compatible)
192New/Replacement of 66 kV Lasfor R&M66/11 kv s/s
193New/Replacement of 33 kV Lasfor R&M33/11 kv s/s
194New/Replacement of 66 kV CTsfor R&M66/11 kv s/s
195New/Replacement of 33 kV CTsfor R&M33/11 kv s/s
196New/Replacement of 66 kVPTsfor R&M66/11 kv s/s
197New/Replacement of 33 kVPTsfor R&M33/11 kv s/s
198New/Replacement of 66 kV isolatorwith earthing bladefor R&M66/11 kv s/s
199New/Replacement of 33 kV isolatorwith earthing bladefor R&M33/11 kv s/s
200New/Replacement of 66 kV isolatorwithout earthing blade for R&M66/11 kv s/s
201New/Replacement of 33 kV isolatorwithout earthing blade for R&M33/11 kv s/s
202Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 66/11 kV S/s
203Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s
204Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 66/11 kV S/s
205Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s
20611kVGO switich for R&M66/11 kv s/s
20711kVGO switich for R&M33/11 kv s/s
20811kV LA setsfor R&M66/11 kv s/s
20911kV LA setsfor R&M33/11 kv s/s
210Battery Bankfor R&M66/11 kv s/s
211Battery Bankfor R&M33/11 kv s/s
212Battery Chargerfor R&M66/11 kv s/s
213Battery Chargerfor R&M33/11 kv s/s
214Fire Extinguisher systemfor R&M66/11 kv s/s
215Fire Extinguisher systemfor R&M33/11 kv s/s
216Powercable 11kV 400sqmm for R&M33/11 kv s/s
217Powercable 11kV 400sqmm for R&M66/11 kv s/s
218ACDBfor R&M33/11 kv s/s
219ACDBfor R&M66/11 kv s/s
220DCDBfor R&M33/11 kv s/s
221DCDBfor R&M66/11 kv s/s
22211 kV VCB Switchgear Panel Board (Scada Compatible) (1 Incomer Panel + 4 Outgoing Panel) for R&M 66/11 kV S/s
22311 kV VCB Switchgear Panel Board (Scada Compatible) (1 Incomer Panel + 4 Outgoing Panel) for R&M 33/11 kV S/s