Power Development Department has published Tender For Ht / Lt And Sub Station Works In Kishtwar District Under Pmdp-R-Rural Electrification Works Of Kishtwar District In Jammu Province Under Pmdp ( Rural ) - 1 66/11 kV, 10 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer wi. Submission Date for this Tender is 14-10-2021. Substation Tenders in KISHTWAR DISTRICT RURAL AREAS Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Sep-2021 | CORRIGENDUM1 | Other | 11-10-2021 |
2 | 04-Oct-2021 | CORRIGENDUM 2 | Financial Bid | 11-10-2021 |
3 | 08-Oct-2021 | CORRIGENDUM 3 | Date | 14-10-2021 |
4 | 08-Oct-2021 | CORRIGENDUM 4 | Other | 14-10-2021 |
5 | 13-Oct-2021 | CORRIGENDUM 5 | Financial Bid | 14-10-2021 |
Sl. No. | Item Description |
1 | 66/11 kV, 10 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
2 | 66/11 kV, 6.3 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
3 | 66/11 kV, 8 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
4 | 33/11 kV, 8 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
5 | 33/11 kV, 10 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
6 | 33/11 kV, 3.15 MVA,3 Phase Power Transformer,Copper winding, Off-load tap changer with HT and LT connectors |
7 | 33/11 kV, 6.3 MVA,3 Phase Power Transformer,Copper winding, On-load tap changer with HT and LT connectors |
8 | 66 kV, 1250Amp, 31.5 kA SF6 Circuit Breaker |
9 | Control & Relay Panel for protection of 66/11 kV Power Transformerwith differential Relay (SCADA Compatible) |
10 | Control & Relay Panel for protection of 66/11 kV Power Transformer without differentialrelay (SCADA Compatible) |
11 | Control & Relay Panel for 66 kV Feeder VCB (SCADA Compatible) |
12 | 66 kV, Multi Ratio , Multi Core , Single Phase Current Transformer |
13 | 66 kV, Multi Ratio ,Multi Core , Voltage Transformer |
14 | 66 kV Lightening Arrestors |
15 | 66 kV, 800 A Isolator with Earthing Blade |
16 | 66 kV, 800 A, Isolator without Earthing Blade |
17 | 66 kV Post Insulator |
18 | Disc Insulators for 66 KV Line Bay |
19 | 33 KV Disc Insulators complete with fitting |
20 | Control & Relay Panel for protection of 33/11 kV Power Transformerwith differential relay (SCADA Compatible) |
21 | Control & Relay Panel for protection of 33/11 kV Power Transformerwithout differential relay (SCADA Compatible) |
22 | 33 kV, 1250 Amp, 25 kA for 3 sec, Outdoor Vacuum Circuit Breaker |
23 | 33 kV, 25 kA for 3 sec, Voltage Transformer, 33/0.11 kV |
24 | 33 kV, 25 kA for 3 sec, Single Phase Current Transformer |
25 | Control & Relay Panel for 33 kV Feeder VCB (SCADA Compatible) |
26 | 33 kV, 800 A, Isolator with Earthing Blade |
27 | 33 kV, 800 A, Isolator without Earthing Blade |
28 | 30 kV Lightening Arrestors |
29 | 2 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc. |
30 | 4 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc. |
31 | 6 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc. |
32 | 12 Core2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc. |
33 | 30 V Battery Bank ,100 AH,of 15 No. cells of 2V each,sealed maintaince free VRLA type ,high Impact polyprophelene coplymer conatiner ,flame retardant(for new 66/11 KV Substation) |
34 | 30V, 100 AH,Float-cum booster charger ,with Full wave rectification for 220 V, 1 Phase , 50hz AC Input Supply. |
35 | Construction of RCC foundation for Power Transformersincuding guide rail, considering original equipment manufacturer recommendations includingshuttering and by providing reinforcement, cement concreting in 1:1.5:3,painting etc as per Technical Specification, approved Drawings & Scope of works. |
36 | 66 kV/33KV Yard Concreting/Metalling for new Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge. |
37 | 66 kV/33KV Yard Concreting/Metalling for addl Transformer Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge. |
38 | Construction of RCC foundation for outdoor mounted 66 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. |
39 | Construction of RCC foundation for 33 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. |
40 | Construction of RCC foundation for 33KV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. (for additional X-MER) |
41 | Chainlink Fencing of 66 kV/33KV Yard of Substation by way of Mass Concrete in Foundationsandchainlink fencing of 6 ft height (for new 66/11 KV or 33/11 KV Substation) |
42 | Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 820 mm) |
43 | Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 750 mm) |
44 | Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 500 mm) |
45 | Compound walling of identified landby way of Mass Concrete in Foundationsand228 mm Brick Wall of 2 M height (for new 66/11 kV or 33/11 kV Substation) with provision of double beam. |
46 | Design, engineering & construction of Control Room Building for new 33/11 & 66/11 kV receiving substation (13mX8.5m c/c) consisting of RCC Slab including indoor trenches, comprising of battery room, panel room, store room, administration room, toilet etc as required of overall building sizeas per electrical requirement/ approved drawing ,single story including all internal services like water supply, Sewerage system, Finishing, Plinth Protection, including supply of construction materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation etc, complete in all resect including , Internal wiring, water proofing and roof projections of 600x600mm as per detailed Technical Specification, approved Drawings & Scope of works. |
47 | Development of land by removing weeds, wild grass, levelling and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains and station FGL. |
48 | Borewell with submersible pump (at new receiving substation) |
49 | Earthing Mat with GI Flat 50x8 (for new receiving substation) with 50X6 risers. |
50 | Design, engineering & construction ofShift Quarters for JE and SBA at new 66/11 & 33/11 KV Substation as per instruction of Engineer-in-charge complete in all resect as per detailed Technical Specification, approved Drawings & Scope of works |
51 | Retaining Wall(RCC type) |
52 | Retaining Wall (Stone masonry type) |
53 | Soil Filling for new/additional substations |
54 | Earthing Electrode (3m long 40mm dia GI pipe) forAdd. Receiving Substation Earth Mat |
55 | Yard Lighting of the new receiving sub station using 4 no , 12 meter long, GI High Mast poles ,continuously tapered of octagonal ofcross-section ; including suitable shallow raft foundation using8 nos 250 watt non integral flood light luminaire with single piece die cast aluminum housing and pot optic reflector and toughened glass cover, conforming to IP-66 complete with all accessories and suitable control feeder panel. |
56 | Earth Mat with GI Flat 50X8 & 50X6 risers for Additional Power Transformer |
57 | Earthing of Augmented Power Transformer |
58 | D.C Distribution Board with distributional Panel( 30V, DC) with 1 No. Amp Ckt. Breaker (for 66/11 kV newSubstations) |
59 | A.C Distribution Boardwith distribution panel (415 V,AC) complete with Ckt .breaker ,including Lamp etc (for 66/11 kV new Substations) |
60 | Fire Fighting Equipment (for 66/11 kV newSubstations) a). Dry Chemical powder type(6kg) forcontrol room -3No. b.) CO2 type of 4.5 kg Capacity for Control room- 4No. c).CO2 type trolly mounted of 22.5kg capacity for switch yard 2No. |
61 | 11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 3 Outgoing Panel) (SCADA Compatible) |
62 | 11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 4 Outgoing Panel) (SCADA Compatible) |
63 | 11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 5 Outgoing Panel) (SCADA Compatible) |
64 | 11 kv Isolator double break 3 pole ,600 A with Earth switch |
65 | 11 kV L.Afor (66/11 kv S /s, 33/11 KV s/s & for DTR structure )(10 kA Stn type.) |
66 | 100 KVA, 11/0.4 KV Stn. Transformer, Aluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014 for (New 33/11 kV & 66/11 kV S/s) |
67 | 11 KV XPLE Power Cables- 3C 120 mm² |
68 | 11 KV XPLE Power Cables- 3C 185 mm² |
69 | 11 KV XPLE Power Cables- 3C 300 mm² |
70 | 11 KV XPLE Power Cables- 3C 400 mm² |
71 | 11 KV XPLE Power Cables- Single Core 630 sq mm (With one spare length) |
72 | Indoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable |
73 | Indoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable |
74 | Indoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable |
75 | Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable |
76 | Indoor Type Cable Termination Kit for Single core 630 sq mm Cable |
77 | 0utdoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable |
78 | Outdoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable |
79 | Outdoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable |
80 | Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable |
81 | Outdoor Type Cable Termination Kit for Single core 630 sq mm Cable |
82 | Disc Insulators for 33 KV Line Bay |
83 | Single Tension Fittings for Panther Conductor |
84 | 50 mm² LT AB Cable (3X50+1x16+1X35 mm²) |
85 | 70 mm² LT AB Cable (3X70+1x16+1X50 mm²) |
86 | 120 mm² LT AB Cable (3X120+1x16+1X95 mm²) |
87 | 35 mm² HT AB Cable (3X35+1X70 mm²) |
88 | 50 mm² HT AB Cable (3X50+1X70 mm²) |
89 | 70 mm² HT AB Cable (3X70+1X95 mm²) |
90 | 120 mm² HT AB Cable (3X120+1X95 mm²) |
91 | Insulating Piercing Connetors |
92 | 200 sqmm ACSR Panther Conductor |
93 | 150 sqmm ACSRWolf Conductor |
94 | 100 sqmm ACSRDog Conductor |
95 | 50 sqmm ACSRRabbit Conductor |
96 | 30 sqmm ACSR Weasel Conductor |
97 | 11/0.433 kV, 630 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
98 | 11/0.433 kV, 400 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
99 | 11/0.433 kV, 250 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
100 | 11/0.433 kV, 63 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
101 | 11/0.433 kV, 100 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
102 | 11/0.433 kV, 25 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ) |
103 | 120 mm² LT4Core PVC Cable |
104 | 400 mm² Single Core XLPE Cable (1100 V) |
105 | 240 mm² Single Core XLPE Cable (1100 V) |
106 | 185 mm² Single Core XLPE Cable (1100 V) |
107 | 150 mm² Single Core XLPE Cable (1100 V) |
108 | 120 mm² Single Core XLPE Cable (1100 V) |
109 | 95 mm² Single Core XLPE Cable (1100 V) |
110 | 70 mm² Single Core XLPE Cable (1100 V) |
111 | 50 mm² Single Core XLPE Cable (1100 V) |
112 | 25 mm² Single Core XLPE Cable (1100 V) |
113 | 33 kV Pin Insulators with Pin |
114 | 11kV Pin Insulators with Pin |
115 | 11KV GO, AB Switch 200 Amp |
116 | 11kV Disc Insulators complete with fitting |
117 | 11 kV DO FUSE 100 A |
118 | 33 kV Post Insulator |
119 | 20 mm dia Stay Set complete with Stay Wire 7/4 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc |
120 | 16 mm dia Stay Set complete with Stay Wire 7/3.15 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc. |
121 | Grouting of Stay Set as per TD/approved drawings |
122 | 66 kV Disc Insulators Complete with fitting |
123 | Suspension fitting for Wolf Conductor(66 kV Line) |
124 | Earthing of Poles & fittings by GI earthing Rod 20x2500 mm & 6 SWG GI wire |
125 | Tension Fitting for Wolf Conductor |
126 | 8 Mtr.Long PCCPoleWL-250 Kg |
127 | 11 Mtr. Long PCC Pole WL- 360 kg |
128 | 9 Mtr. Long PCCPoleWL-300 Kg |
129 | 16 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -80(IS 2713, Pt I, II, III 1980.) |
130 | 13 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -69 (IS 2713, Pt I, II, III 1980.) |
131 | 11 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -56 (IS 2713, Pt I, II, III 1980.) |
132 | 8 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -15 (IS 2713, Pt I, II, III 1980.) |
133 | 9 Mtr. Long Steel Tubular Polewith welded steel base plate of Designation 410 SP -33(IS 2713, Pt I, II, III 1980.) |
134 | Stone Pad for PCC poles (400x400x75) |
135 | Aluminium Jointing Sleeves |
136 | Aluminium Paint |
137 | Red Oxide |
138 | Anti-Climbing Device with Clamps |
139 | Cement concrete foundation of ST Poles using cement concreting , 1 part cement, 2 part sand,4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings (Tentative 0.45 cum/pole) |
140 | 66 kV Danger Plates with Clamps |
141 | 33 kV Danger Plates with Clamps |
142 | 11kV Danger Plates with Clamps |
143 | 440 V Danger Plates with Clamps |
144 | DLMS type Meter for DT Metering with Modem |
145 | Meter Box with Resin Cast Ring type CTs for DT Metering |
146 | Earthing LT Pole ( GI Earthing spike made of 20mm solid rod or 8 SWG earthing coil) |
147 | Earthing of Distribution Transformer - Pipe earthing. |
148 | 11 kV Outgoing feeders- Pipe earthing.with GI strip |
149 | 25mm dia GI Rod 3 M long for earth mat |
150 | Earth wire (7/4.00 sqmm) |
151 | Eye Bolts for guard netting |
152 | GI Wire 6 SWG, 8 SWG as per requirement for guard netting |
153 | Galvanised Steel Structures /GI Channel X-arm and GI V-cross armincluding clamps and braces/GI Channels/Angle/ Flats of sizes. |
154 | Galvanized Nuts & Bolts |
155 | GI Barbed Wire for Anti Climbing with clamps (35 turns / pole) |
156 | GI flat for earthing 50x6 mm (for 33 kV Line Bay) |
157 | GI Strip 25x3 mm for earthing of DTR, |
158 | GI U-Clamps for Shackle Insulators |
159 | LT Distribution Box with mounting clamps for 25 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
160 | LT Distribution Box with mounting clamps for 63 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
161 | LT Distribution Box with mounting clamps for 100 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
162 | LT Distribution Box with mounting clamps for 250 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
163 | LT Distribution Box with mounting clamps for 400 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
164 | LT Distribution Box with mounting clamps for 630 KVA DTR with MCCBs with suitable incoming and outgoing ckts |
165 | Transformer Pad (for 400 kVA & 630 kVA DTRs) |
166 | LT Line Spacers |
167 | MCCB - 200 Amps (with Enclosure and pole mounting arrangement) for 100 kVA, 11/0.4 kV station Transformer |
168 | PG Clamps for 200 mm² ACSR Conductor |
169 | PG Clamps for 150 mm² ACSR Conductor |
170 | PG Clamps for 100 mm² ACSR Conductor |
171 | PG Clamps for 30 mm² ACSR Conductor |
172 | PG Clamps for 50 mm² ACSR Conductor |
173 | PG for LT AB Cable |
174 | Shackle Insulators with Pin |
175 | Sundry items like aluminium lugs, Jumpers, binding Tape, Droppers etc. |
176 | Suspension/Tension Clamp with eye hook |
177 | T Clamps for Panther Conductor |
178 | Wedge Connectors / PG Clamps |
179 | Straight Through for LT AB Cable Joining Kit |
180 | Soil Cutting |
181 | Approach Road to the substation land if required |
182 | LT 3 phase pole Distribution box with busbar LT service connection |
183 | 35 sqmm 4C PVC Cable |
184 | Safety and operation instrument |
185 | Provision for Bus- bar & 11 kV supporting Structures (for Aug Transformers) |
186 | Heat Shrinkable Outdoor Cable Termination Kit |
187 | Mid Span Straight Through Jointing Kit for 11 KV ABC |
188 | New /Replacement 66kV SF6 for R&M66/11 kv s/s |
189 | New /Replacement 33kV VCBs for R&M33/11 kv s/s |
190 | New 66kV C& R Panels for R&M66/11 kv s/s (Scada Compatible) |
191 | New 33kV C& R Panels for R&M33/11 kv s/s (Scada Compatible) |
192 | New/Replacement of 66 kV Lasfor R&M66/11 kv s/s |
193 | New/Replacement of 33 kV Lasfor R&M33/11 kv s/s |
194 | New/Replacement of 66 kV CTsfor R&M66/11 kv s/s |
195 | New/Replacement of 33 kV CTsfor R&M33/11 kv s/s |
196 | New/Replacement of 66 kVPTsfor R&M66/11 kv s/s |
197 | New/Replacement of 33 kVPTsfor R&M33/11 kv s/s |
198 | New/Replacement of 66 kV isolatorwith earthing bladefor R&M66/11 kv s/s |
199 | New/Replacement of 33 kV isolatorwith earthing bladefor R&M33/11 kv s/s |
200 | New/Replacement of 66 kV isolatorwithout earthing blade for R&M66/11 kv s/s |
201 | New/Replacement of 33 kV isolatorwithout earthing blade for R&M33/11 kv s/s |
202 | Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 66/11 kV S/s |
203 | Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s |
204 | Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 66/11 kV S/s |
205 | Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s |
206 | 11kVGO switich for R&M66/11 kv s/s |
207 | 11kVGO switich for R&M33/11 kv s/s |
208 | 11kV LA setsfor R&M66/11 kv s/s |
209 | 11kV LA setsfor R&M33/11 kv s/s |
210 | Battery Bankfor R&M66/11 kv s/s |
211 | Battery Bankfor R&M33/11 kv s/s |
212 | Battery Chargerfor R&M66/11 kv s/s |
213 | Battery Chargerfor R&M33/11 kv s/s |
214 | Fire Extinguisher systemfor R&M66/11 kv s/s |
215 | Fire Extinguisher systemfor R&M33/11 kv s/s |
216 | Powercable 11kV 400sqmm for R&M33/11 kv s/s |
217 | Powercable 11kV 400sqmm for R&M66/11 kv s/s |
218 | ACDBfor R&M33/11 kv s/s |
219 | ACDBfor R&M66/11 kv s/s |
220 | DCDBfor R&M33/11 kv s/s |
221 | DCDBfor R&M66/11 kv s/s |
222 | 11 kV VCB Switchgear Panel Board (Scada Compatible) (1 Incomer Panel + 4 Outgoing Panel) for R&M 66/11 kV S/s |
223 | 11 kV VCB Switchgear Panel Board (Scada Compatible) (1 Incomer Panel + 4 Outgoing Panel) for R&M 33/11 kV S/s |