| Sl. No. | Item Description |
| 1 | Part A- SUPPLY OF ITEMSGeneral Notes:a. All items under this section shall be quoted for supply as per enclosed Technical Specification & Data Sheets including packaging& forwarding, loading, freight, insurance, import duty, unloading at a designated place within the Project Site, spares, etc. b. The rates to be quoted shall also be inclusive of software upgrades for the supplied softwares, for a period of 3 years beyond the date of issuance of Mechanical Completion.b. Third party inspection for the supply items shall be in tenderer\"s scope. Approval of TPI agency to be engaged shall be obtained from IOCL on award of contract. c. Refer Particular Technical Specification / Datasheets given in the tender for all details including warranty.d. All materials to be supplied shall be based on compliance to Particular Technical Specification / Data Sheet to be submitted by successful bidder including applicable QAP / ITP with prior clearance / approval by IOCL/ its Consultant. |
| 2 | SECTION 1: MECHANICAL |
| 3 | Marine Loading Arms |
| 4 | Marine Loading Arm, Size 12\", 300#, Product: LPG (Propane & Butane), Material: LTCS, Electro-Hydraulic operated, including spare parts for commissioning and spare parts for 2 years operation, Emergency Release Coupling (ERC) and Hydraulic Quick Connect/ Disconnect Cargo Couplers (QC/DC). |
| 5 | Marine Loading Arm, Size 12\", 300#, Product: POL (MS, HSD, ATF & SKO), Material: Carbon Steel, Electro-Hydraulic operated, including spare parts for commissioning and spare parts for 2 years operation, Emergency Release Coupling (ERC) and Hydraulic Quick Connect/ Disconnect Cargo Couplers (QCDC). |
| 6 | Hydraulic Power Unit (HPU) common for all the above MLAs |
| 7 | Gangway Tower |
| 8 | Hydraulic operated telescopic type Ship Access Gangway Tower with steel tower, platform, inclined ladder, bulwark ladder, hydraulic cylinder, HPU, top side jib crane with ground pendant switch control, combination starter, and all associated accessoriesincluding spare parts for commissioning and spare parts for 2 years operation.Upper Level: 19.5 m CDDown Level: 2.1 m C.DJib Crane Capacity: 2.5 MTMax./Min. Radius of Jib Crane: 19 m / 3.5 m |
| 9 | Pig Launcher cum Receiver |
| 10 | Design, Engineering, Manufacture & fabrication, Procurement of materials & bought out components, assembly at shop, inspection, testing at manufacturer\"s works, preparation of shipment / packing, transport, delivery of the Bi-directional launcher cum receiver suitable for accomodating intelligent pigs & other cleaning / displacement / gauging pigs, fitted with Quick Opening End Closure (QOEC) suitable for horizontal installation including all accessories required to make Bi-Directional Launcher & Receiver system complete operational and QOEC shall be hand operated by a single lever operation and operable by one operator.Scope of supply shall include but not limited to supply & placement of perforated SS Tray inside the Bi-Directional Launcher & Receiver, supply and mounting of Pig Signaller on the Bi-Directional launcher & receiver, supply of Pig Signaller for mounting on pipeline, supply of Pig Handling (insertion / retraction) System including supply of mating flanges for all the flanged end Nozzle. Required studs, Nuts, bolts, Gaskets and foundation Bolts for Bi-Directional Launcher & receiver and associated accessories for all the items as detailed below : |
| 11 | Bi-directional Pig Launcher cum Receiver (of size 36\" x 30\" NB & ANSI Class 150) along with Band lock type Quick Opening End Closure (QOEC), all required Nozzles, vent, drain, flanges, gaskets and bolting - 2 Nos |
| 12 | Non-intrusive type (Ultrasonic) Pig Signaller mounted on Pig Launcher cum Receiver- 2 Nos |
| 13 | Supply of Door Seal for Quick Opening End Closure (QOEC) [Commissioning Spares] - 4 Nos |
| 14 | Non-intrusive type (Ultrasonic) Pig Signaller mounted on 30\" NB Pipeline - 2 Nos |
| 15 | Jib Crane of capacity 3T to suit the pig handling for scrapper trap as specified above - 1 No |
| 16 | Pig Handling System with insertion / retraction facilities for inserting / pulling the SS Tray / Pigs to suit the scrapper trap - 2 Nos |
| 17 | EOT Crane (for Fire Water Pump House) |
| 18 | 10T Capacity Double Girder EOT Crane including bridge structure, travelling mechanism, hoisting mechanism, service platform, brake mechanism, electric motors, trailing cables, AC variable frequency controls for all motions, lighting fixtures and all other necessary accessories.Building Span: 15.70 mBay Length: 44.00 mLifting Height: 6.40 mArNo Classification: Non-HazardousOperation: Pendant + Radio Remote Control |
| 19 | Slop Tanks |
| 20 | Design, Engineering, Manufacture & fabrication, Procurement of materials & bought out components, assembly at shop, inspection, testing at manufacturer\"s works, preparation of shipment / packing, transport, delivery of Horizontal, cylindrical, pit mounted (below deck) POL Slop Tanks (one each for MS, HSD, ATF & SKO) incl. shell, flat ends, nozzles, boot for slop pump mounting, manhole with davit arrangement, saddle supports, stiffener plates and RF pads, internal piping, earthing cleats, nameplates, anchor bolts etc.Design Standard: IS 10987 (latest edition)Internal Diameter: 2200 mmLength: 9000 mmMaterial: MS (IS 2062 Gr.B) |
| 21 | Design, Engineering, Manufacture & fabrication, Procurement of materials & bought out components, assembly at shop, inspection, testing at manufacturer\"s works, preparation of shipment / packing, transport, delivery of Horizontal, cylindrical, pit mounted (below deck) POL Slop tank incl. shell, flat ends, Nozzles, boot for slop pump mounting, manhole with davit arrangement, saddle supports, stiffener plates and RF pads, internal piping, Northing clNots, nameplates, anchor bolts etc.Design Standard: IS 10987 (latest edition)Internal Diameter: 1700 mmLength: 8500 mmMaterial : MS (IS 2062 Gr.B) |
| 22 | Slop Pumps |
| 23 | Vertical, Extended Shaft, Submerged Sump Pump (VS-4) type vessel mounted Slop pumps for POL products (one each for MS, HSD, ATF & SKO) including drive motor, coupling with coupling guard, common base frame for each pump and motor, complete sealing / cooling / lubrication system, counter flanges with bolts, nuts & gaskets, Local Control Panel (LCP) etc.Rated Flowrate: 36 m3/hr.TDH: 100 MLCMOC: ASTM A48 CL 30 (Casing) / ASTM A351 CF8 (Impeller) |
| 24 | Vertical, Extended Shaft, Submerged Sump Pump (VS-4) type vessel mounted slop pumps including drive motor, coupling with coupling guard, common base frame for each pump and motor, complete sealing / cooling / lubrication system, counter flanges with bolts, nuts & gaskets, Local Control Panel (LCP) etc.Rated Flowrate: 10 m3/hr.TDH: 100 MLCMOC: ASTM A48 CL 30 (Casing) / ASTM A351 CF8 (Impeller) |
| 25 | Instrument Air System |
| 26 | Oil Flooded, Rotary Screw type Compressor complete with electric motor, common baseplate or skid for compressor with all components, individual suction air filters, oil filter, air cooled intercooler & aftercooler, Auto drain traps with bypass valve, safety valves, instruments & controls, microprocessor based local control unit for each compressor etc.Capacity (each) / FAD : 200 Nm3/hr. (incl. purge air loss)Guaranteed output at package outlet terminal point : 170 Nm3/hr.Discharge Pressure at package outlet: 7 barg |
| 27 | Vertical, cylindrical, dished end type air receiver (one at compressor discharge and two at dryer discharge) complete with manhole, pressure indicators, temperature indicators, automatic drain trap, block valves for instruments, manual drain line with valve etc.Capacity of Compressed Wet Air Receiver : Bidder to decideCapacity of each Instrument Dry Air Receiver : 5 m3MOC: IS 2002 Gr. 2A/2B or IS 2062 |
| 28 | Heatless purge type air drier including twin towers with a pressure / temperature safety relief valve, pressure indicator, purge volume control valve, purge flow meter, silencer, thermostatic devices, dew point alarm and indication equipment, control and alarm circuit etc. Following items are also included:a) 1 (One) set of pre-filter for each drier including differential pressure indicator, automatic drain traps with bypass, and block valves for maintenanceb) 1 (One) set of After-filter for each drier including differential pressure indicator, alarm, automatic drain traps with bypass, and block valves for maintenancec) 1 (One) relay based control system for Air Drier |
| 29 | Supply of all integral piping including necessary internal pipes, fittings, instruments, drains and vents with isolation valve, supports within package unit |
| 30 | Vapour Eliminators |
| 31 | Vertical, Cylindrical type Vapour Eliminators to separate any carry over liquid in the incoming nitrogen gas supply including all necessary accessories.Design Pressure: 6 bargMOC: Carbon Steel (ASTM A516 Gr.70)Dimension (Approx.): 2 m (Dia) x 3.5 m (Height)Inlet: 16\"Vapour Outlet: 10\" |
| 32 | Flame Arresters |
| 33 | Vertical, inline Flame Arrestor Assembly complete with all necessary accessories (Suitable for Zone 2 Gas Group IIA/IIB, Temperature Class: T3) : |
| 34 | 10\", 150#, MOC: Carbon Steel (Body) / Flame Element (SS 316L) |
| 35 | 2\", 150#, MOC: Carbon Steel (Body) / Flame Element (SS 316L) |
| 36 | Air Operated Double Diaphragm Pump |
| 37 | Portable Metallic Air Operated Double Diaphragm Pump with all necessary accessories.Housing: Carbon SteelWorking Fluid: POLCapacity: 10000 LPHDischarge Head: 20 MLC |
| 38 | Nitrogen System |
| 39 | Design, Engineering, Manufacture & fabrication, Procurement of materials & bought out components,inspection, testing at manufacturer\"s works, preparation of shipment / packing, transport, delivery of Nitrogen system comprising ofmodules of liquid Nitrogen storage tank with vaporisers as per Particular Technical Specification along with integral and interconnecting piping and instrumentation, civil foundations and installation cost. Note: The successful bidder shall get the entire design done and approved by IOCL prior to procurement and installation of Nitrogen Storage System. |
| 40 | SECTION 2 : PIPING |
| 41 | Supply of CS Seamless Pipes to API 5L Gr. X52, Dim. ASME B36.10 |
| 42 | 750mm NB SCH THK. 10.3mm Bevel ends |
| 43 | Supply of CS Seamless Pipes to ASTM A106 Gr.B, Dim. ASME B36.10 |
| 44 | 25mm NB SCH S-80 Plain ends |
| 45 | 50mm NB SCH S-80 Bevel ends |
| 46 | 80mm NB SCH S-STD Bevel ends |
| 47 | 100mm NB SCH S-STD Bevel ends |
| 48 | 150mm NB SCH S-STD Bevel ends |
| 49 | 200mm NB SCH S-STD Bevel ends |
| 50 | 250mm NB SCH S-STD Bevel ends |
| 51 | 300mm NB SCH S-STD Bevel ends |
| 52 | 400mm NB SCH S-STD Bevel ends |
| 53 | 500mm NB SCH S-STD Bevel ends |
| 54 | 600mm NB SCH S-STD Bevel ends |
| 55 | Supply of CS Seamless Pipes to ASTM A333 Gr.6, Dim. ASME B36.10 |
| 56 | 25mm NB SCH S-160 Plain ends |
| 57 | 450mm NB SCH S-30 Bevel ends |
| 58 | 300mm NB SCH S-40 Bevel ends |
| 59 | 50mm NB SCH S-80 Bevel ends |
| 60 | Supply of CS Galvanized Seamless Pipes to ASTM A106 Gr.B, Dim. ASME B36.10 |
| 61 | 25mm NB SCH S-80 MTE |
| 62 | 25mm NB SCH S-80 PE X MTE 100 mm Long |
| 63 | 50mm NB SCH S-STD Bevel Ends |
| 64 | 80mm NB SCH S-STD Bevel Ends |
| 65 | Supply of SSSeamless Pipes to ASTM A312 Gr.TP316L, Dim. ASME B36.19 |
| 66 | 50mm NB SCH S-40S Bevel Ends |
| 67 | 25mm NB SCH S-40S Plain Ends |
| 68 | 25mm NB SCH S-40S Plain Ends X MTE 100 mm LONG |
| 69 | PIPEFITTINGS: Supplying the following sizes of Elbows/ Tees/ Reducer made of seamless pipes with ends as per tender specifications for the following sizesNote: The fittings shall be Socket Welded for Sizes Less than 2\" as per ASME B 16.11 and Bevel ends for 2\" andabove and dimensions as per ASME B 16.9 |
| 70 | 90 Deg BEND API5L Gr.X52 (Hot Pulled Bend fabricated out of supplied pipes) |
| 71 | 750mm NB SCH THK. 10.3mm |
| 72 | 90 Deg LR ElbowASTM A234 Gr.WPB |
| 73 | 25mm NB Class 3000 |
| 74 | 50mm NB Class 3000 |
| 75 | 80mm NB SCH S-STD |
| 76 | 100mm NB SCH S-STD |
| 77 | 150mm NB SCH S-STD |
| 78 | 200mm NB SCH S-STD |
| 79 | 250mm NB SCH S-STD |
| 80 | 300mm NB SCH S-STD |
| 81 | 400mm NB SCH S-STD |
| 82 | 500mm NB SCH S-STD |
| 83 | 600mm NB SCH S-STD |
| 84 | 90 Deg LR Elbow ASTM A420 Gr.WPL6 |
| 85 | 450mm NB SCH S-30 |
| 86 | 300mm NB SCH S-40 |
| 87 | 50mm NB SCH S-80 |
| 88 | 90 Deg LR Elbow ASTM A234 Gr.WPB (GALV.) |
| 89 | 25mm NB SCH S-80 MTE |
| 90 | 50mm NB SCH S-STD |
| 91 | 80mm NB SCH S-STD |
| 92 | 90 Deg LR ElbowASTM A403 Gr.WP316L |
| 93 | 25mm NB SCH S-40S |
| 94 | 50mm NB SCH S-40S |
| 95 | 45 Deg BEND API5L Gr.X52 |
| 96 | 750mm NB SCH THK. 10.3mm |
| 97 | 45 Deg LR ElbowASTM A234 Gr.WPB |
| 98 | 50mm NB SCH S-80 Plain ends |
| 99 | 200mm NB SCH S-STD |
| 100 | 250mm NB SCH S-STD |
| 101 | 300mm NB SCH S-STD |
| 102 | 400mm NB SCH S-STD |
| 103 | 45 Deg LR ElbowASTM A420 Gr.WPL6 |
| 104 | 450mm NB SCH S-30 |
| 105 | 50mm NB SCH S-80 |
| 106 | 45 Deg LR ElbowASTM A234 Gr.WPB (GALV.) |
| 107 | 50mm NB SCH S-STD |
| 108 | 80mm NB SCH S-STD |
| 109 | 45 Deg LR Elbow ASTM A403 Gr.WP316L |
| 110 | 50mm NB SCH S-40S |
| 111 | Equal Tee ASTM A234 Gr.WPB |
| 112 | 50mm NB Class 3000 |
| 113 | 100mm NB SCH S-STD |
| 114 | 150mm NB SCH S-STD |
| 115 | 250mm NB SCH S-STD |
| 116 | 300mm NB SCH S-STD |
| 117 | 400mm NB SCH S-STD |
| 118 | 600mm NB SCH S-STD |
| 119 | Equal Tee ASTM A420 Gr.WPL6 |
| 120 | 300mm NB SCH S-40 |
| 121 | Equal Tee ASTM A234 Gr.WPB (GALV.) |
| 122 | 80mm NB SCH S-STD |
| 123 | Equal Tee ASTM A403 Gr.WP316L |
| 124 | 50mm NB SCH S-40S |
| 125 | Reducing Tee ASTM A234 Gr.WPB |
| 126 | 50 X 15 mm NB CL 3000 |
| 127 | 50 X 25 mm NB CL 3000 |
| 128 | 100 X 50 mm NB S-STD x S-80 |
| 129 | 150 X 80 mm NBS-STD x S-STD |
| 130 | 150 X 100 mm NBS-STD x S-STD |
| 131 | 200 X 100 mm NBS-STD x S-STD |
| 132 | 250 X 100 mm NBS-STD x S-STD |
| 133 | 300 X 200 mm NBS-STD x S-STD |
| 134 | 400 X 200 mm NBS-STD x S-STD |
| 135 | 600 X 400 mm NBS-STD x S-STD |
| 136 | Reducing Tee ASTM A234 Gr.WPB (GALV.) |
| 137 | 50 X 25 mm NBS-STD x S-80 |
| 138 | 80 X 50 mm NBS-STD x S-80 |
| 139 | Reducing Tee (1.5D) ASTM A403 Gr.WP316L |
| 140 | 50 X 25 mm NBS-40S x S-40S |
| 141 | Concentric Reducer ASTM A234 Gr.WPB |
| 142 | 100 X 50 mm NB S-STD x S-80 |
| 143 | 500 X 300 mm NBS-STD x S-STD |
| 144 | 600 X 500 mm NBS-STD x S-STD |
| 145 | Concentric Reducer ASTM A420 Gr.WPL6 |
| 146 | 50 X 25 mm NBS-80 x S-80 |
| 147 | 80 X 50 mm NBS-80 x S-80 |
| 148 | Coupling ASTM A105 |
| 149 | 25mm NB Class 3000 SWE |
| 150 | Coupling ASTM A105 (GALV.) |
| 151 | 25mm NB Class 3000 FTE |
| 152 | 50mm NB Class 3000 FTE |
| 153 | Coupling ASTM A182 Gr.F316L |
| 154 | 25mm NB Class 3000 SWE |
| 155 | Plug ASTM A105 (GALV.) |
| 156 | 25mm NB Class 3000 FTE |
| 157 | 50mm NB Class 3000 FTE |
| 158 | PIPEFITTINGS: Supplying the following sizes of Olets made of as per MSS SP 97 specifications for the following sizes |
| 159 | SOCKOLET ASTM A105 |
| 160 | 100 X 20 Class 3000 |
| 161 | 100 X 25 Class 3000 |
| 162 | 150 X 50 Class 3000 |
| 163 | 300 X 25 Class 3000 |
| 164 | 300 X 50 Class 3000 |
| 165 | 600 X 40 Class 3000 |
| 166 | 750 X 40 Class 3000 |
| 167 | SOCKOLETASTM A350 Gr.LF2 |
| 168 | 300 X 40 Class 3000 |
| 169 | SOCKOLET ASTM A105 (GALV.) |
| 170 | 80 X 15 Class 3000 |
| 171 | Weldolet ASTM A105 |
| 172 | 600 X 50 SCH S-80 |
| 173 | 400 X 100 SCH S-STD |
| 174 | 600 X 80 SCH S-STD |
| 175 | 600 X 100 SCH S-STD |
| 176 | WeldoletASTM A350 Gr.LF2 |
| 177 | 300 X 50 SCH S-80 |
| 178 | Supply of following Socket Weld type - SWRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 179 | 25mm NB |
| 180 | 50mm NB |
| 181 | Supply of following Socket Weld type - SWRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 182 | 25mm NB |
| 183 | Supply of following Weld neck type- WNRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 184 | 80mm NB SCH S-STD |
| 185 | 100mm NB SCH S-STD |
| 186 | 150mm NB SCH S-STD |
| 187 | 200mm NB SCH S-STD |
| 188 | 250mm NB SCH S-STD |
| 189 | 300mm NB SCH S-STD |
| 190 | 400mm NB SCH S-STD |
| 191 | 500mm NB SCH S-STD |
| 192 | 600mm NB SCH S-STD |
| 193 | Supply of following Weld neck type - WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 150 |
| 194 | 50mm NB SCH S-80 |
| 195 | Supply of following Weld neck type - WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 196 | 450mm NB SCH S-30 |
| 197 | 300mm NB SCH S-40 |
| 198 | 50mm NB SCH S-80 |
| 199 | Supply of following Weld neck type - WNRF 125 AARH as per ASTM A 694 Gr. F52 DIM. ASME B16.47 Series B Class 150 |
| 200 | 750mm NB SCH THK. 10.3mm |
| 201 | Supply of following Slip On type - SORF 125 AARH as per ASTM A105 (GALV.) DIM. ASME B16.5 Class 150 |
| 202 | 50mm NB SCH S-STD |
| 203 | 80mm NB SCH S-STD |
| 204 | Supply of following Weld neck type - WNRF 125 AARH as per ASTM A182-F316L DIM. ASME B16.5 Class 150 |
| 205 | 50mm NB SCH S-40S |
| 206 | Supply of following BLRF 125 AARH flanges as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 207 | 50mm NB |
| 208 | 100mm NB |
| 209 | 150mm NB |
| 210 | 300mm NB |
| 211 | 600mm NB |
| 212 | Supply of following BLRF 125 AARH flanges as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 150 |
| 213 | 50mm NB |
| 214 | Supply of following BLRF 125 AARH flanges as per ASTM A105 (GALV.) DIM. ASME B16.5 Class 150 |
| 215 | 80mm NB |
| 216 | Supply of following BLRF 125 AARH flanges as per ASTM A182-F316L DIM. ASME B16.5 Class 150 |
| 217 | 50mm NB |
| 218 | Supply of following GASKET, 4.5mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 150 |
| 219 | 25mm NB |
| 220 | 50mm NB |
| 221 | 80mm NB |
| 222 | 100mm NB |
| 223 | 150mm NB |
| 224 | 200mm NB |
| 225 | 250mm NB |
| 226 | 300mm NB |
| 227 | 400mm NB |
| 228 | 500mm NB |
| 229 | 600mm NB |
| 230 | 750mm NB |
| 231 | Supply of following GASKET, 4.5mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 300 |
| 232 | 25mm NB |
| 233 | 50mm NB |
| 234 | 300mm NB |
| 235 | 450mm NB |
| 236 | Supply of following HEXAGONAL NUT, ASTM A194 Gr.2H, ASME B18.2.2, FTE, Hot Dip Galvanized |
| 237 | 1\" Dia |
| 238 | 1/2\" Dia |
| 239 | 1-1/4\" Dia |
| 240 | 1-1/8\" Dia |
| 241 | 3/4\" Dia |
| 242 | 5/8\" Dia |
| 243 | 7/8\" Dia |
| 244 | Supply of following HEXAGONAL NUT, ASTM A194 Gr.8M, ASME B18.2.2, FTE |
| 245 | 5/8\" Dia |
| 246 | Supply of following STUD BOLT, ASTM A193 Gr.B7, ASME B18.2.1, MTE, Hot Dip Galvanized |
| 247 | 1\" Dia150 MM LONG |
| 248 | 1/2\" Dia75 MM LONG |
| 249 | 1-1/4\" Dia185 MM LONG |
| 250 | 1-1/8\" Dia175 MM LONG |
| 251 | 3/4\" Dia110 MM LONG |
| 252 | 3/4\" Dia120 MM LONG |
| 253 | 3/4\" Dia200 MM LONG |
| 254 | 5/8\" Dia100 MM LONG |
| 255 | 5/8\" Dia95 MM LONG |
| 256 | 7/8\" Dia130 MM LONG |
| 257 | 7/8\" Dia135 MM LONG |
| 258 | 1-1/8\" Dia160 MM LONG |
| 259 | 5/8\" Dia95 MM LONG |
| 260 | Supply of following STUD BOLT,ASTM A193 Gr.B8M CL.2, ASME B18.2.1, MTE |
| 261 | 5/8\" Dia95 MM LONG |
| 262 | Supplying the following sizes of CS Manual Ball Valves (ASTM A105 flanged # 800 ) as per Specification |
| 263 | 15 mm Dia |
| 264 | 25 mm Dia |
| 265 | 50 mm Dia |
| 266 | Supplying the following sizes of CS Motor Operated Ball Valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 267 | 100 mm Dia |
| 268 | 150 mm Dia |
| 269 | 200 mm Dia |
| 270 | 250 mm Dia |
| 271 | 300 mm Dia |
| 272 | Supplying the following sizes of CS Manual Globe Valves (ASTM A105 flanged # 800 ) as per Specification |
| 273 | 25 mm Dia |
| 274 | Supplying the following sizes of CS Motor Operated Globe Valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 275 | 200 mm Dia |
| 276 | 250 mm Dia |
| 277 | Supplying the following sizes of CS Manual Globe Valves (ASTM A 352 Gr. LCB flanged # 800 ) as per Specification |
| 278 | 25 mm NB |
| 279 | Supplying the following sizes of CS Manual Ball Valves (ASTM A 352 Gr. LCB flanged # 150 ) as per Specification |
| 280 | 50 mm NB |
| 281 | Supplying the following sizes of CS Manual Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 282 | 50 mm NB |
| 283 | Supplying the following sizes of SS Manual Ball Valves (ASTM A182 Gr. F316L flanged # 150 ) as per Specification |
| 284 | 25 mm NB |
| 285 | Supplying the following sizes of SS Manual Globe Valves (ASTM A182 Gr. F316L flanged # 800 ) as per Specification |
| 286 | 25 mm NB |
| 287 | Supplying the following sizes of SS Manual Ball Valves (ASTM A351 GR CF3 flanged # 150 ) as per Specification |
| 288 | 50 mm NB |
| 289 | Supplying the following sizes of SS Manual Globe Valves (ASTM A351 GR CF3 flanged # 150 ) as per Specification |
| 290 | 50 mm NB |
| 291 | Supplying the following sizes of CS Check Valves (ASTM A105 flanged # 800 ) as per Specification |
| 292 | 25 mm NB |
| 293 | Supplying the following sizes of CS Check Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 294 | 50 mm Dia |
| 295 | 100 mm Dia |
| 296 | 200 mm Dia |
| 297 | 300 mm Dia |
| 298 | 600 mm Dia |
| 299 | Supplying the following sizes of CS Excess Flow Check Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 300 | 300 mm dia |
| 301 | Supply of Thermal relief valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 302 | 25mm X 50mm Dia TRV |
| 303 | Supply of Thermal relief valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 304 | 25mm X 50mm Dia TRV |
| 305 | Supply of Pressure relief valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 306 | 50mm X 50mm Dia SRV |
| 307 | 100mm X 150mm Dia SRV |
| 308 | Supplying the following sizes of CS Motor Operated Ball Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 309 | 50 mm Dia |
| 310 | 100 mm Dia |
| 311 | 150 mm Dia |
| 312 | 400 mm Dia |
| 313 | 600 mm Dia |
| 314 | 750 mm Dia |
| 315 | Supplying the following sizes of CS Motor Operated Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 316 | 300 mm Dia |
| 317 | 450 mm Dia |
| 318 | 600 mm Dia |
| 319 | Supplying the following sizes of CS Motor Operated Globe Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 320 | 600 mm Dia |
| 321 | Supplying the following sizes of CS Electro Hydraulic Butterfly Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 322 | 600 mm Dia |
| 323 | Supplying the following sizes of CS Pneumatic Control Globe Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 324 | 250 mm Dia |
| 325 | 500 mm Dia |
| 326 | Supplying the following sizes of CS Pneumatic Control Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 327 | 300 mm Dia |
| 328 | U-Bolt |
| 329 | 15 mm Dia |
| 330 | 25 mm Dia |
| 331 | 50 mm Dia |
| 332 | 80 mm Dia |
| 333 | 100 mm Dia |
| 334 | TEFLON PAD ASSEMBLY |
| 335 | ORIFICE PLATE 3MM & 6MM #300, |
| 336 | 80 mm Dia |
| 337 | 100 mm Dia |
| 338 | SPECTACLE BLIND |
| 339 | 25 mm Dia |
| 340 | 50 mm Dia |
| 341 | 80 mm Dia |
| 342 | 100 mm Dia |
| 343 | FLOW TEE |
| 344 | Material :- ASTM A234 Gr.WPB (Pipe Material API5L Gr.X52,)Size : -DN 750 X DN 600Schedule :- 10.3mm THK X STD |
| 345 | SECTION 3 : ELECTRICAL |
| 346 | Supply of 2 POLE STRUCTURE: 2 pole Structure including RSJs, ISMCs for 11 kV Incoming Power Supply with Gang operated isolator, D.O. fuse with base, lightning arrestors, earthing, padlocking for 2 Pole structure as per attached specification, data sheet including supply of commissioning spares, as required. |
| 347 | Supply of HT Panel: |
| 348 | 11 kV, 630 A, 3 phase, 3 wire, 25 kA for 1 sec. rated switchgear with all accessories and spares as per single line diagram, specification and data sheet as attached with the tender document. |
| 349 | 11 kV, 630 A, 3 phase, 3 wire, 25 kA for 1 sec. rated single VCB cubicle (ICOG type panel) with all accessories and spares as per single line diagram , specification and data sheet as attached with the tender document. |
| 350 | Distribution Transformer: Distribution of the following ratings as per attached specification, data sheetincluding supply of spares, as required. |
| 351 | 200 kVA, 11/0.433 kV dry type transformer with all fittings and accessories as per specification.Location: 5 acre plot substation room |
| 352 | 630 kVA, 11/0.433 kV dry type transformer with all fittings and accessories as per specification.Location : Substation room at jetty control building |
| 353 | Supply of DG Set |
| 354 | 125 kVA, 415 V, 3 phase, 0.8 PF DG Set & AMF Panel with all fittings and accessories like lube oil system, cooling system, diesel oil system, all required piping, exhaust piping & support structure, day oil tank each along with all pipings with magnetic level switch,inter connecting cables and cable accessories, base channels etc. as per attached specification, data sheet & SLD including supply of spares, as required, First filling of engine oil, lubricant etc. The supply includes Residential silencer & spark arrestor.Location: DG Shed of 5 acre plot |
| 355 | 600 KVA, 415V, 3 phase, 0.8 PF DG Set & AMF Panel complete with all required accessories like lube oil system, cooling system, diesel oil system, all required piping, day oil tank along with all pipings with magnetic level switch,inter connecting cables and cable accessories, base channels etc. as per attached specification, data sheet & SLD including supply of spares, as required, First filling of engine oil, lubricant etc. The supply includes Residential silencer & spark arrestor. Location: DG Room at jetty control building |
| 356 | Supply of MV & LV Switch board/Panels/Sub Distribution Boards. |
| 357 | EPMCC Panel: 415 V, 400 A, 3 phase, 4 wire, 25 kA for 1 sec. rated Onshore EPMCC with all accessories and spares as per single line diagram, specification and data sheet.Location - 5 acre plot substation room |
| 358 | EPMCC Panel: 415 V, 1250 A, 3 phase, 4 wire, 40 kA for 1 sec. rated Jetty EPMCC with all accessories and spares as per single line diagram, specification and data sheet.Location - Substation room at jetty control building |
| 359 | Onshore ACDB: 415 V, 100 A, 3 phase, 4 wire, 25 kA for 1 sec. rated Onshore ACDB with all accessories as per single line diagram, specification and data sheet.Location - 5 acre plot substation room |
| 360 | Jetty ACDB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated Jetty ACDB with all accessories and spares as per single line diagram, specification and data sheetLocation - Substation Room at Jetty Control Building |
| 361 | MOV DB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated MOV DB with all accessories and spares as per single line diagram, specification and data sheetLocation - Substation room at Jetty Control Building |
| 362 | HVAC DB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated HVAC DB with all accessories and spares as per single line diagram, specification and data sheetLocation - Substation room at Jetty Control Building |
| 363 | APFC Panel: 25 kVAR, 415 V Capacitor bank with APFC as per specification, data sheet and single line diagramLocation - Substation room at Jetty Control Building |
| 364 | Supply of Lighting Distribution Board & Lighting Panel |
| 365 | LDB: 415 V, 63 A, 3 phase, 4 wire, 10 kA for 1 sec. rated onshore area lighting DB with 25 kVA 0.415/0.433 kV lighting transformer and with all accessories as per specification. Incomer: 63 A, 3 phase, 1 No. Outgoing: 32 A, 3 phase, 6 Nos..Location - 5 acre plot substation room |
| 366 | LDB: 415 V, 100 A, 3 phase, 4 wire, 10 kA for 1 sec. rated jetty area lighting DB with 50 kVA 0.415/0.433 kV lighting transformer and with all accessories as per specification. Incomer: 100 A, 3 phase 1 No. Outgoing: 63 A, 3 phase 9 Nos.Location - Substation room at jetty control building |
| 367 | LP: Indoor Non FLP type lighting panel as per specification with all accessories. Incomer: 32 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 6 Nos. |
| 368 | LP: Indoor Non FLP type lighting panel as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 369 | LP: Outdoor FLP type (Ex-d, IIA/IIB, T3) as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 370 | LP: Outdoor Non FLP type as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 371 | Supply of UPS System |
| 372 | 2x100% 10 kVA, 240 V AC UPS with maintenance bypass and UPSDB for onshore area as per single line diagram, specification and data sheet (including supplying the required capacity of VRLA SMF type battery and spares for UPS)Location - 5 acre plot substation room |
| 373 | 2x100% 20 kVA, 230 V AC UPS with maintenance bypass and UPSDB for Jetty area as per single line diagram, specification and data sheet ( including supplying the required capacity of VRLA SMF type battery and spares for UPS )Location- Substation room at Jetty Control Building |
| 374 | SWITCH BOARD WORKS: Supplying Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer\"s specification and direction of PMC Engineer/ Owner. |
| 375 | Flush mounted “ON/OFF’ switch board made of 16SWG GI concealed sheet metal box with Cover of reputed make consisting of following items as per manufacturer\"s specification and direction of PMC Engineer/ Owner.note: All switch/socket mentioned below are indicative, however,Bidder has to supply the switch/socket as per requirement. |
| 376 | 3 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of PMC Engineer/ Owner. |
| 377 | 6 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of PMC Engineer/ Owner. |
| 378 | 9 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of PMC Engineer/ Owner. |
| 379 | GI & Stainless steel Prefabricated Ladder/Perforated Type Cable Tray & other cable raceway material |
| 380 | Supply of the following cable tray material including supply of coupler plates, nut, bolts, saddle, clamps, welding rods and other fixing accessories as per specification |
| 381 | 600 (W) x 100 (H) ladder type GI cable tray |
| 382 | 600 (W) x 100 (H) perforated type GI cable tray |
| 383 | 300 (W) x 100 (H) ladder type GI cable tray |
| 384 | 300 (W) x 100 (H) perforated type GI cable tray |
| 385 | 150 (W) x 50 (H) ladder type GI cable tray |
| 386 | 150 (W) x 50 (H) perforated type GI cable tray |
| 387 | 50 (W) x 50 (H) perforated type GI cable tray |
| 388 | 600 (W) x 100 (H) ladder type Stainless steel cable tray |
| 389 | 600 (W) x 100 (H) perforated type Stainless steel cable tray |
| 390 | 300 (W) x 100 (H) ladder type Stainless steel cable tray |
| 391 | 300 (W) x 100 (H) perforated type Stainless steel cable tray |
| 392 | 150 (W) x 50 (H) ladder type Stainless steel cable tray |
| 393 | 150 (W) x 50 (H) perforated type Stainless steel cable tray |
| 394 | 50 (W) x 50 (H) perforated type Stainless steel cable tray |
| 395 | 90 degree Vertical bend for 600 (W) x 100 (H) ladder type GI cable tray |
| 396 | 90 degree Vertical bend for 600 (W) x 100 (H) perforated type GI cable tray |
| 397 | 90 degree Vertical bend for 300 (W) x 100 (H) ladder type GI cable tray |
| 398 | 90 degree Vertical bend for 300 (W) x 100 (H) perforated type GI cable tray |
| 399 | 90 degree Vertical bend for 150 (W) x 50 (H) ladder type GI cable tray |
| 400 | 90 degree Vertical bend for 150 (W) x 50 (H) perforated type GI cable tray |
| 401 | 90 degree Vertical bend for 600 (W) x 100 (H) ladder type Stainless steel cable tray |
| 402 | 90 degree Vertical bend for 600 (W) x 100 (H) perforated type Stainless steel cable tray |
| 403 | 90 degree Vertical bend for 300 (W) x 100 (H) ladder type Stainless steel cable tray |
| 404 | 90 degree Vertical bend for 300 (W) x 100 (H) perforated type Stainless steel cable tray |
| 405 | 90 degree Vertical bend for 150 (W) x 50 (H) ladder type Stainless steel cable tray |
| 406 | 90 degree Vertical bend for 150 (W) x 50 (H) perforated type Stainless steel cable tray |
| 407 | 90 degree Horizontal bend for 600 (W) x 100 (H) ladder type GI cable tray |
| 408 | 90 degree Horizontal bend for 600 (W) x 100 (H) perforated type GI cable tray |
| 409 | 90 degree Horizontal bend for 300 (W) x 100 (H) ladder type GI cable tray |
| 410 | 90 degree Horizontal bend for 300 (W) x 100 (H) perforated type GI cable tray |
| 411 | 90 degree Horizontal bend for 150 (W) x 50 (H) ladder type GI cable tray |
| 412 | 90 degree Horizontal bend for 150 (W) x 50 (H) perforated type GI cable tray |
| 413 | 90 degree Horizontal bend for 600 (W) x 100 (H) ladder type Stainless steel cable tray |
| 414 | 90 degree Horizontal bend for 600 (W) x 100 (H) perforated type Stainless steel cable tray |
| 415 | 90 degree Horizontal bend for 300 (W) x 100 (H) ladder type Stainless steel cable tray |
| 416 | 90 degree Horizontal bend for 300 (W) x 100 (H) perforated type Stainless steel cable tray |
| 417 | 90 degree Horizontal bend for 150 (W) x 50 (H) ladder type Stainless steel cable tray |
| 418 | 90 degree Horizontal bend for 150 (W) x 50 (H) perforated type Stainless steel cable tray |
| 419 | Tee for 600 (W) x 100 (H) ladder type GI cable tray |
| 420 | Tee for 600 (W) x 100 (H) perforated type GI cable tray |
| 421 | Tee for 300 (W) x 100 (H) ladder type GI cable tray |
| 422 | Tee for 300 (W) x 100 (H) perforated type GI cable tray |
| 423 | Tee for 150 (W) x 50 (H) ladder type GI cable tray |
| 424 | Tee for 150 (W) x 50 (H) perforated type GI cable tray |
| 425 | Tee for 600 (W) x 100 (H) ladder type Stainless steel cable tray |
| 426 | Tee for 600 (W) x 100 (H) perforated type Stainless steel cable tray |
| 427 | Tee for 300 (W) x 100 (H) ladder type Stainless steel cable tray |
| 428 | Tee for 300 (W) x 100 (H) perforated type Stainless steel cable tray |
| 429 | Tee for 150 (W) x 50 (H) ladder type Stainless steel cable tray |
| 430 | Tee for 150 (W) x 50 (H) perforated type Stainless steel cable tray |
| 431 | Pre-fabricated cover for 600 (W) x 100 (H) tray |
| 432 | Pre-fabricated cover for 300 (W) x 100 (H) tray |
| 433 | Pre-fabricated cover for 150 (W) x 50 (H) tray |
| 434 | ISA 50x50x6 |
| 435 | ISMC 100 |
| 436 | 6 mm thick chequred plate |
| 437 | MCT block with wall frame assembly for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 438 | MCT block with wall frame assembly for 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 439 | MCT block with wall frame assembly for 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 440 | MCT block with wall frame assembly for 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 441 | MCT block with wall frame assembly for 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 442 | MCT block with wall frame assembly for 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 443 | MCT block with wall frame assembly for 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 444 | MCT block with wall frame assembly for 1kV 4Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 445 | MCT block with wall frame assembly for 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 446 | MCT block with wall frame assembly for 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 447 | MCT block with wall frame assembly for 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 448 | MCT block with wall frame assembly for 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 449 | MCT block with wall frame assembly for 1kV 3Cx120 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 450 | MCT block with wall frame assembly for 1kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 451 | MCT block with wall frame assembly for 1kV 1Cx400 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 452 | MCT block with wall frame assembly for 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 453 | MCT block with wall frame assembly for 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 454 | MCT block with wall frame assembly for 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 455 | Supply of Fire sealing compound |
| 456 | Outdoor Lighting: note: The successful tenderer shall make use of the items under this section and obtain design sufficiency from the electrical lighting & luminaire manufactures for achieving necessary lighting lux level at various areas as per the OISD requirements. Galvanisation is 610 gms/sq. mtr |
| 457 | Supply of High Mast and Street Light Pole |
| 458 | Hot dip galvanised High Mast lighting tower (30m height) including foundation bolts, all accessories including 16 Nos x 350 watt LED fixture with lamp, head frame, Twin Aviation Obstruction lamps, Lightening Arrestor with down conductors, stainless steel rope, double drum winch, junction boxes, FLP plugs and sockets, FLP Feeder box, galvanised lantern carrier arrangement, Lighting fixtures, double compression steel glands and accessories, tinned copper cable lugs of suitable size and type, cables and cable accessories from light fittings upto FLP feeder box etc. as per specification an standard installation details including supply of commissioning spares, as required. |
| 459 | 9 Mtr GI street Lighting Pole(Octagonal or polygonal section; Galvanisation of610 gms/sq. mtr) for ground mounting, complete with base plate, foundation bolts, all accessories, weather proof JBs at the foot of the pole & terminal block (as applicable), Zinc passivated hardware for fixtures support & pole support, GI pipe for cable (Class B) protection, clamps, nuts, bolts, etc. including supply of commissioning spares, as required as per specification and standard installation details. |
| 460 | 4.5 Mtr Swan Neck GI Lighting Pole (50mm as per IS 1239 - Medium duty; Galvanisation of 610 Gms/ sqm)for structural mounting, complete with all clamping arrangements for cables including accessories, Zinc passivated hardware for fixtures support & pole support, clamps, nuts, bolts, etc. including supply of commissioning spares, as per specification, data sheet and standard installation details. |
| 461 | Supply of Junction Box |
| 462 | Two way FLP type junction boxes as per specification including the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 463 | Three way FLP type junction boxes as per specificationincluding the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 464 | Four way FLP type junction boxes as per specification including the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 465 | Supply of Local Control Station |
| 466 | Flameproof (Ex’d’) Local Control Station with components as listed below and with Aluminium alloy (LM6 grade) enclosure as per Specification, Data Sheet and direction of PMC Engineer/ Owner. |
| 467 | With Start and Emergency Stop Push Button and Ammeter |
| 468 | With Start and Emergency Stop Push Button |
| 469 | Supply of Non FLP Local Control Station with components as listed below and with sheet steel enclosure as per Specification, Data Sheet and direction of Engineer-in-charge. |
| 470 | With Start and Emergency Stop Push Button and Ammeter |
| 471 | With Start and Emergency Stop Push Button |
| 472 | Supply of FLP & Non FLP type Switch Socket & Plug |
| 473 | Supply of FLP Interlocking type switch sockets and plugs as per attached specifications & data sheets. All switch sockets shall be provided with 3mm thick FRP caNopy with side cover and FLP stopping plug as per specification and direction of PMC Engineer/ Owner. |
| 474 | 415V, 3 phase 63A FLP switch socket and plug suitable for 3.5CX95 Sq.mm. cable entry |
| 475 | 415V, 3 phase 63A Non FLP switch socket and plug suitable for 3.5CX95 Sq.mm. cable entry |
| 476 | 240 V, 1 phase, 5/15A,FLP Switch Socket and plug and suitable for 3 C x 4 sqmm cable entry |
| 477 | 240 V, 1 phase, 5/15A,Non FLP Switch Socket and plug and suitable for 3 C x 4 sqmm cable entry |
| 478 | Supply of Other Lighting Material |
| 479 | Heavy duty PVC Coduits - 19 mm for concealed wiring as per specification |
| 480 | Heavy duty PVC Coduits - 25 mm for concealed wiring as per specification |
| 481 | Rigid steel Coduits - 19 mm for exposed wiring for fire water pump house and wire house as per specification |
| 482 | Rigid steel Coduits - 25 mm for exposed wiring for fire water pump house and wire house as per specification |
| 483 | Flexible PVC conduit |
| 484 | Flexible steel conduit |
| 485 | 3 way Circular JB/pull box as per specification |
| 486 | 4 way Circular JB/pull box as per specification |
| 487 | Ceiling Fan |
| 488 | 1200mm Sweep ceiling Fan with Down Rod |
| 489 | Regulator for sweep ceiling Fan |
| 490 | 900mm Sweep ceiling Fan with Down Rod |
| 491 | 300mm. Sweep Wall Fan |
| 492 | Supply of HT/ LT Power and Control cables with Aluminium / Copper conductor XLPE insulated FRLS/FS armoured cables of different voltage grade and types of the following sizes in directly buried / supported on structure / pull through pipes including supply and fixing of strip number tags, supply and fixing of clamps, saddles and saddle bars, etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tenderand directions of PMC Engineer/ Owner. |
| 493 | 11 kV (UE) armoured, XLPE, FRLS Power Cable of following size:- |
| 494 | 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 495 | 1.1 KV Grade, Armoured, XLPE, FRLS Aluminium/ Copper Power Cable of following sizes: |
| 496 | 1kV 1Cx400 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 497 | 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 498 | 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 499 | 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 500 | 1kV 4Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 501 | 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 502 | 1kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 503 | 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 504 | 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 505 | 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 506 | 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 507 | 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 508 | 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 509 | 1.1 KV Grade, Armoured, PVC, FRLS Copper Control Cable of following sizes |
| 510 | 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 511 | 1kV 7Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 512 | 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 513 | 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 514 | 1.1 KV XLPE, FRLS Lighting Cable / Flexible cable/ Wires of following size |
| 515 | 3Cx2.5 (CU) PVC FLEXIBLE cable(unarmoured) |
| 516 | 1Cx2.5(CU) FRLS PVC WIRE |
| 517 | 1.1kV, XLPE, FS armoured, Cable of following size:- |
| 518 | 1kV 2Cx2.5 sq. mm Cu FS cable |
| 519 | 1kV 3Cx6 sq. mm Cu FS cable |
| 520 | 1kV 3Cx120 sq. mm Al FS cable |
| 521 | Supply of Double compression, weather proof (Non FLP), brass cable glands suitable for following XLPE/PVC , FRLS cable sizes & as per relevant IS for Indoor/outdoor use. |
| 522 | 1.1 KV Grade, Armoured, XLPE, FRLS Aluminium/ Copper Power Cable of following sizes: |
| 523 | 1kV 1Cx400 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 524 | 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 525 | 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 526 | 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 527 | 1kV 4Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 528 | 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 529 | 1kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 530 | 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 531 | 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 532 | 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 533 | 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 534 | 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 535 | 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 536 | 1.1 KV Grade, Armoured, PVC, FRLS Copper Control Cable of following sizes |
| 537 | 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 538 | 1kV 7Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 539 | 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 540 | 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 541 | 1.1kV, XLPE, FS armoured, Cable of following size:- |
| 542 | 1kV 2Cx2.5 sq. mm Cu FS cable |
| 543 | 1kV 3Cx6 sq. mm Cu FS cable |
| 544 | 1kV 3Cx120 sq. mm Al FS cable |
| 545 | Supply of FLP double compression brass Cable Gland for hazardous area |
| 546 | 1.1 KV Grade, Armoured, XLPE, FRLS Aluminium/ Copper Power Cable of following sizes: |
| 547 | 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 548 | 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 549 | 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 550 | 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 551 | 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 552 | 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 553 | 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 554 | 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 555 | 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 556 | 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 557 | 1.1kV armoured XLPE, FRLS Control Cable of following size:- |
| 558 | 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 559 | 1kV 7Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 560 | 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 561 | 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 562 | 1.1kV armoured XLPE, FRLS Lighting Cable of following size:- |
| 563 | 3CX2.5 SQMM Cu |
| 564 | Supply of HT End Termination & Jointing Kit |
| 565 | Heat shrinkable end termination kit/jointing kit suitable for 11 kV (UE) XLPE, FRLS armoured cables of following sizes. |
| 566 | Outdoor type heat shrinkable termination kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 567 | Indoor type heat shrinkable termination kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 568 | Jointing kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 569 | Supply of GI Pipe for cable Protection Class-B Galvanized Iron (G.I. pipes) complete with accessories (bends, reducers, couplers etc.) of following sizes:- |
| 570 | 150 mm NB |
| 571 | 100 mm NB |
| 572 | 75 mm NB |
| 573 | 50 mm NB |
| 574 | 25 mm NB |
| 575 | Earth Pit: Supplying earth pit material as per IS-3043 standard specifications with following sizes medium quality, Class-B, GI pipe ( 65mm dia, 3 mtr. long continuous pipe and Not welded in parts) fabricated as per IS. The job includes supply of charcoal or coke dust mixed with salt clay (salt 0.5%) including all hardware, accessories as per specifications and drawings |
| 576 | Earth Pit for electronic earthing: Supplying 600x600x3 copper plate earth pit material as per IS-3043 standard specifications. The job includes supply of charcoal or coke dust mixed with salt clay (salt 0.5%) including all hardware, accessories as per specifications and drawings |
| 577 | Supply of Hot Dip Galvanized G.I./Cu earth strips (Galvanisation of 610 gm/ sqm of exposed area), PVC insulated Cu cable of following sizes for earthing and lightning protection. |
| 578 | 50x6 mm GS flat as main earth grid conductor and earthing of major equipment |
| 579 | 50x6 mm Cu flat as earthing conductor for coonection with pile reinforment bar which will act as earth grid termination with sea water |
| 580 | 8 SWG Solid GI Wire |
| 581 | 10MM GI wire rope |
| 582 | 35X6 mm GI Flat for earthing & lightning protection conductor |
| 583 | 25 sq.mm. Braided Cu Flexible Cable |
| 584 | Hot dip galvanized GI earth bus bar of size 400 X 75X 6 thick with fixing materials as per Drg. |
| 585 | 25 mm dia 1 m long GI rod for vertical air termination |
| 586 | Flexible cable for static earth - 20 m long 25 sq. mm flexible Cu cable with lug at one end and crocodile clip at other end |
| 587 | Test Linkboxfor lightning protection |
| 588 | SAFETY ITEMS: Supply & installation of Following items for electrical and general safety |
| 589 | 11kV, 1000mm wide, electric grade floor rubber mat conforming to relevant IS. ISI mark to be available on rubber mat. |
| 590 | 1.1KV, 1000mm wide, electric grade floor rubber mat (in pieces of length Not less than 2 mtrs.) conforming to relevant IS:15652. ISI mark shall be there on rubber mat. |
| 591 | Discharge rod (11kV) telescopic fiber glass heavy duty with necessary earthing facilities & wires. |
| 592 | Shock treatment chart ( laminated type) as per IS:5216 in trilingual language (Hindi /English/Tamil) duly laminated on a hard back ground to be hung at various places |
| 593 | Rubber Hand Glovesof 11kV grade |
| 594 | Rubber Hand Glovesof 1.1kV grade |
| 595 | Vitreous enamel caution boards (HINDI/ ENGLISH/TAMIL) as per IS 2551 |
| 596 | 11000 V |
| 597 | 440 V |
| 598 | Firstaidboxof GI as per IS:13115, 18 SWG sheetwith necessaryitems. |
| 599 | LED Lighting Fixtures & Accessories |
| 600 | Supply of Weather proof Lighting Fixtures, Lamps & accessories as per specifications. (All Lighting fixtures shall be provided with required No. of double compression cable glands and stopper plugs as required including tinned copper cable lugs of suitable type for termination) |
| 601 | 40W Linear LED Light (Bajaj Cat No.- BLTRU 40W VIVA or approved equivalent) |
| 602 | 36W Planner Recess Mounting Type LED Light suitable for false celling ( Bajaj BCTBLR 36W LED or approved equivalent) |
| 603 | 100W High bay LED Fitting (BAJAJ 13499 BGHB 100W future or approved equivalent) |
| 604 | 3W Single Side Display LED EXIT with ARROW (with 2HR. Battery backup) |
| 605 | 10W LED Suspended Mounting Weatherproof Bulkhead Luminaries(BAJAJ BIBWP 10W LED or approved equivalent) |
| 606 | 20W LED surface mounted Normal Luminaries(PHILIPS SM134VPSD W60L60 or approved equivalent) |
| 607 | 30W Peripheral LED Light ( Bajaj Cat No.- BCLST 30W LED or approved equivalent) |
| 608 | 100 W LED street light type fixture as per specification ( Bajaj Cat No.- BRTFG 100W LED I or approved equivalent) |
| 609 | 120 W LED Flood Light (Bajaj Cat No- BAR FEG 120 W or approved equivalent) including all accessories |
| 610 | Flame proof Lighting Fixture & Accessories |
| 611 | 50W LED Well glass Light fittings ( Baliga Cat. No.-FLPW-1245L LED 50W or approved equivalent) |
| 612 | 36 W surface mounted flameproof type LED fixture (NoTON cat. No.TFC 6135Z NoTON-TUFFLITE IP66 or approved equivalent) |
| 613 | Supply of Solar Power Generation System |
| 614 | Design, Detail Engineering, Supply of required equipment and material for solar power generation system using a plot of 50 m x 20 m as per specification (Doc No. P.011265-E-11097-01 ) and single line diagram (Drg. No. P.011265-E-21004-001). Minimum Power generation: 100 kWpeakLocation - 5 acre plot |
| 615 | SECTION 4 : FIREFIGHTING |
| 616 | Supply of Remote Controlled Tower mounted water cum foam monitor (UL Listed) with Fire Proof Structure (25 m high) as per specifications and data sheetsFlowrate: 2000 GPM |
| 617 | Complete Foam System including Vertical Cylindrical, coned bottom type Foam Tanks (2 x 12 m3 capacity each), 2 Nos. Electric motor driven Rotary Gear type Foam Pumps of 600 LPM Capacity & 15 bar head, Inline Balanced Pressure Proportioner (4 Nos.), 1 (one) No. Foam Filling Pump (25 m3/hr. capacity & 20 MLC head), 1 (one) No. flexible hose of 15 m length, piping, fittings, valves, instruments, etc. complete |
| 618 | Vertical Wet Pit type, Diesel Engine Driven Fire Water Pumps of Capacity950 m3/hr & TDH 120 MLC including water cooled diesel engine, fuel piping, fuel tank, lube oil system, air intake system, industrial silencer, exhaust piping with insulation & aluminium cladding, caisson pipe, companion flanges, air release valve, PRV, controller with pressure sensing line with two check valves, etc.Design Standard: NFPA 20Casing Material: Duplex SSMain FW Pumps shall be Non-UL Listed/ Non-FM Approved type. |
| 619 | Vertical Wet Pit type, Electric Motor driven Jockey Pumps of Capacity 190 m3/hr & TDH 125 MLC including drive motor, starter, caisson pipe, companion flanges, air release valve, controller with pressure sensing line with two check valves, etc.Design Standard: NFPA 20Casing Material: Duplex SSJockey Pumps shall Not be UL Listed. |
| 620 | Supply of Jumbo Curtain Nozzles on the unloading platform.Discharge Capacity: 6000 LPM @ 7 kg/cm2 gWorking Pressure Range: 7 - 11 kg/cm2 gHorz. Traverse / Vertical Traverse: 40/15 mAngle of Spray: 180 DegMOC: SS 316 |
| 621 | Supply of two numbers single outlet landing valve of size 63 mm diaas per IS:5290, Type-A of SS material including supply and Installation of stand post of size 100 NB with pipe, elbow, cross, RF pad Plate (for pipe to pipe connection) and necessary fittings & flanges including connecting / welding / installing the same in hydrant. |
| 622 | Centralized Clean Agent (Novec 1230) based suppression system including Cylinders, cylinder racks, manifolds, Gas Release Panel, Nozzles, MRS, Abort Switch, pipes, fittings, valves etc. as per NFPA 2001 for the following Rooms: Jetty Control Building:a) Battery Room (Min. Risk Volume - 104 m3)b) Laboratory Room (Min. Risk Volume - 150 m3)c) UPS Room (Min. Risk Volume - 170 m3)d) Equipment Room (Min. Risk Volume - 240 m3)e) Control Room (Min. Risk Volume - 336 m3) |
| 623 | Supply of Valves |
| 624 | Supplying the following sizes of SS Manual Ball Valves (ASTM A182 F316L flanged # 800 ) as per Specification |
| 625 | 15 mm dia |
| 626 | 20 mm dia |
| 627 | 25 mm dia |
| 628 | 50 mm dia |
| 629 | Supplying the following sizes of SS Manual Ball Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 630 | 100 mm dia |
| 631 | 65 mm dia |
| 632 | 80 mm dia |
| 633 | Supplying the following sizes of CS Glass Flake Lining Manual Butterfly Valves (ASTM A216 WCB flanged # 150) as per Specification |
| 634 | 100 mm dia |
| 635 | 150 mm dia |
| 636 | 250 mm dia |
| 637 | 350 mm dia |
| 638 | Supplying the following sizes of CS Glass Flake Lining Motorized Butterfly Valves (ASTM A216 WCB flanged # 150) as per Specification |
| 639 | 200 mm dia |
| 640 | 400 mm dia |
| 641 | Supplying the following sizes of SSMotorized Globe Valves (ASTM A351 CF3M flanged # 150 ) as per Specification |
| 642 | 100 mm dia |
| 643 | Supplying the following sizes of SS Pneumatic Ball Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 644 | 80 mm dia |
| 645 | Supplying the following sizes of Duplex SS Manual Gate Valves (ASTM A182 F51 flanged # 800 ) as per Specification |
| 646 | 50 mm dia |
| 647 | Supplying the following sizes of CS Check Valves Glass Flake Lining (ASTM A216 WCB flanged # 150 ) as per Specification |
| 648 | 150 mm dia |
| 649 | 350 mm dia |
| 650 | Supplying the following sizes of SS Check Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 651 | 50 mm dia |
| 652 | 80 mm dia |
| 653 | Supply of Pressure relief valves (ASTM A 182 F316L flanged # 150 ) as per Specification |
| 654 | 50mm X 25mm dia SRV |
| 655 | Seamless & Welded Pipes |
| 656 | Supply of Duplex SS Seamless Pipes to ASTM A790 S318032, Dim. ASME B36.10 |
| 657 | 15 mm NB SCH S-40S Plain ends |
| 658 | 25 mm NB SCH S-40S Plain ends |
| 659 | 50 mm NB SCH S-40S Bevel ends |
| 660 | 80 mm NB SCH S-10S Bevel ends |
| 661 | Supply of CS Seamless Pipes to ASTM A106 Gr.B Poly Glass Flake Lining, Dim. ASME B36.10 |
| 662 | 100mm NB SCH S-STD Bevel ends |
| 663 | 150mm NB SCH S-STD Bevel ends |
| 664 | 200mm NB SCH S-STD Bevel ends |
| 665 | 250mm NB SCH S-STD Bevel ends |
| 666 | 350mm NB SCH S-STD Bevel ends |
| 667 | 400mm NB SCH S-STD Bevel ends |
| 668 | 600mm NB SCH S-STD Bevel ends |
| 669 | Supply of SS Seamless Pipes to ASTM A312 Gr.TP 316L, Dim. ASME B36.19 |
| 670 | 15mm NB SCH S-40S Plain Ends |
| 671 | 20mm NB SCH S-40S Plain Ends |
| 672 | 25mm NB SCH S-40S Plain Ends |
| 673 | 50mm NB SCH S-40S Bevel Ends |
| 674 | 80mm NB SCH S-10S Bevel Ends |
| 675 | 100mm NB SCH S-10S Bevel Ends |
| 676 | PIPEFITTINGS: Supplying the following sizes of Elbows/ Tees/ Reducer made of seamless pipes with ends as per enclosed specifications for the following sizesnote: The fittings shall be Socket Welded for Sizes Less than 2\" as per ASME B 16.11 and Bevel ends for 2\" andabove and dimensions as per ASME B 16.9 |
| 677 | 90 Deg LR ElbowASTM A182 F51 |
| 678 | 15mm NB Class 3000 |
| 679 | 25mm NB Class 3000 |
| 680 | 90 Deg LR ElbowASTM A815 WPS31803 |
| 681 | 50mm NB SCH S-10S |
| 682 | 80mm NB SCH S-10S |
| 683 | 90 Deg LR ElbowASTM A234 Gr.WPB Poly Glass Lined |
| 684 | 100mm NB SCH S-STD |
| 685 | 150mm NB SCH S-STD |
| 686 | 200mm NB SCH S-STD |
| 687 | 250mm NB SCH S-STD |
| 688 | 350mm NB SCH S-STD |
| 689 | 400mm NB SCH S-STD |
| 690 | 600mm NB SCH S-STD |
| 691 | 90 Deg LR ElbowASTM A403 Gr.WP316L |
| 692 | 15mm NBClass 3000 |
| 693 | 50mm NB SCH S-40S |
| 694 | 80mm NB SCH S-10S |
| 695 | 100mm NB SCH S-10S |
| 696 | 45 Deg LR ElbowASTM A182F51 |
| 697 | 25mm NB Class 3000 |
| 698 | 45 Deg LR Elbow ASTM A234 Gr.WPB Poly Glass Lined |
| 699 | 200mm NB SCH S-STD |
| 700 | 600mm NB SCH S-STD |
| 701 | 45 Deg LR ElbowASTM A403 Gr.WP316L |
| 702 | 50mm NB SCH S-40S |
| 703 | 80mm NB SCH S-10S |
| 704 | Equal Tee ASTM A815WPS31803 |
| 705 | 50mm NB SCH S-10S |
| 706 | 80mm NB SCH S-10S |
| 707 | Equal Tee ASTM A234 Gr.WPB Poly Glass Lined |
| 708 | 100mm NB SCH S-STD |
| 709 | 150mm NB SCH S-STD |
| 710 | 250mm NB SCH S-STD |
| 711 | Equal Tee ASTM A403 Gr.WP316L |
| 712 | 50mm NB SCH S-40S |
| 713 | 80mm NB SCH S-10S |
| 714 | 100mm NB SCH S-10S |
| 715 | Reducing Tee ASTM A234 Gr.WPB Poly Glass Lined |
| 716 | 100 X 50 mm NBS-STD x S-STD |
| 717 | 100 X 80 mm NBS-STD x S-STD |
| 718 | 150 X 100 mm NBS-STD x S-STD |
| 719 | 350 X 200 mm NBS-STD x S-STD |
| 720 | 350 X 250 mm NBS-STD x S-STD |
| 721 | 400 X 200 mm NBS-STD x S-STD |
| 722 | 600 X 350 mm NBS-STD x S-STD |
| 723 | 600 X 400 mm NBS-STD x S-STD |
| 724 | Reducing TeeASTM A403 Gr.WP 316L |
| 725 | 50 X 20 mm NBS-40S x S-40S |
| 726 | 80 X 5 mm NBS-10S x S-40S |
| 727 | Concentric Reducer ASTM A182 F51 |
| 728 | 25 X 15 mm NB Class 3000 |
| 729 | Concentric Reducer ASTM A815 WPS31803 |
| 730 | 50 X 25 mm NB S-40S x S-40S |
| 731 | Concentric Reducer ASTM A234 Gr.WPB Poly Glass Lined |
| 732 | 100 X 50 mm NBS-STD x S-STD |
| 733 | 150 X 100 mm NBS-STD x S-STD |
| 734 | 350 X 200 mm NBS-STD x S-STD |
| 735 | 350 X 250 mm NBS-STD x S-STD |
| 736 | Concentric Reducer ASTM A182 Gr.F316L |
| 737 | 50 X 25 mm NB S-40S x S-40S |
| 738 | Concentric Reducer ASTM A403 Gr.WP316L |
| 739 | 80 X 50 mm NB S-10S x S-40S |
| 740 | 100 X 50 mm NB S-10S x S-40S |
| 741 | Coupling ASTM A182F51 |
| 742 | 25mm NB Class 3000 SWE |
| 743 | Union ASTM A182F51 |
| 744 | 25mm NB Class 3000 FTE |
| 745 | Cap ASTM A815WPS31803 |
| 746 | 50 mm NB SCH S-40S Bevel ends |
| 747 | PIPEFITTINGS: Supplying the following sizes of Olets made of as per MSS SP 97 specifications for the following sizes |
| 748 | SOCKOLET ASTM A182 Gr. F316L |
| 749 | 50 X 15 Class 3000 |
| 750 | 50 X 20 Class 3000 |
| 751 | 80 X 15 Class 300 |
| 752 | 80 X 20 Class 3000 |
| 753 | 80 X 50 Class 3000 |
| 754 | 100 X 15 Class 3000 |
| 755 | 100 X 20 Class 3000 |
| 756 | Weldolet ASTM A105 Poly Glass Lining |
| 757 | 150 X 50 SCH S-STD |
| 758 | 200 X 50 SCH S-STD |
| 759 | 350 X 50 SCH S-STD |
| 760 | 350 X 100 SCH S-STD |
| 761 | 400 X 150 SCH S-STD |
| 762 | 600 X 50 SCH S-STD |
| 763 | 600 X 100 SCH S-STD |
| 764 | 600 X 150 SCH S-STD |
| 765 | 600 X 200 SCH S-STD |
| 766 | ThreadoletASTM A182 Gr.F51 |
| 767 | 50 X 15 Class 3000 |
| 768 | 80 X 25 Class 3000 |
| 769 | Supply of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 770 | 15mm NB |
| 771 | 25mm NB |
| 772 | 50mm NB |
| 773 | Supply of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 774 | 15mm NB |
| 775 | 20mm NB |
| 776 | Supply of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F316L DIM. ASME B16.5 Class 300 |
| 777 | 25mm NB |
| 778 | 50mm NB |
| 779 | Supply of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 780 | 80mm NB SCH S-10S |
| 781 | Supply of following Weld neck type- WNRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 Poly Glass Lined |
| 782 | 100mm NB SCH S-STD |
| 783 | 150mm NB SCH S-STD |
| 784 | 200mm NB SCH S-STD |
| 785 | 250mm NB SCH S-STD |
| 786 | 350mm NB SCH S-STD |
| 787 | 400mm NB SCH S-STD |
| 788 | 600mm NB SCH S-STD |
| 789 | Supply of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 790 | 50mm NB SCH S-40S |
| 791 | 100mm NB SCH S-10S |
| 792 | Supply of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 300 |
| 793 | 80mm NB SCH S-10S |
| 794 | Supply of following BLRF 125 AARH flanges as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 795 | 100mm NB |
| 796 | Supply of following BLRF 125 AARH flanges as per ASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 797 | 50mm NB |
| 798 | Supply of following Orifice Flange WNRF 125 AARH flanges as per ASTM A182 F316L DIM. ASME B16.36 Class 300 |
| 799 | 80mm NB |
| 800 | Supply of following GASKET, 4.5mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 150 |
| 801 | 15mm NB |
| 802 | 20mm NB |
| 803 | 25mm NB |
| 804 | 50mm NB |
| 805 | 80mm NB |
| 806 | 100mm NB |
| 807 | 150mm NB |
| 808 | 200mm NB |
| 809 | 250mm NB |
| 810 | 350mm NB |
| 811 | 400mm NB |
| 812 | 600mm NB |
| 813 | Supply of following GASKET, 4.5mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 300 |
| 814 | 25mm NB |
| 815 | 50mm NB |
| 816 | 80mm NB |
| 817 | Supply of following HEXAGONAL NUT, ASTM A194 Gr.2H, ASME B18.2.2, FTE, Hot Dip Galvanized |
| 818 | 1\" Dia |
| 819 | 1-1/4\" Dia |
| 820 | 3/4\" Dia |
| 821 | 5/8\" Dia |
| 822 | 7/8\" Dia |
| 823 | Supply of following HEXAGONAL NUT, ASTM A194 Gr.3M, ASME B18.2.2, FTE |
| 824 | 1/2\" Dia |
| 825 | 5/8\" Dia |
| 826 | Supply of following STUD BOLT, ASTM A193 Gr.B7, ASME B18.2.1, MTE, Hot Dip Galvanized |
| 827 | 1\" Dia150 MM LONG |
| 828 | 1-1/4\" Dia 185 MM LONG |
| 829 | 3/4\" Dia 110 MM LONG |
| 830 | 3/4\" Dia 120 MM LONG |
| 831 | 5/8\" Dia 100 MM LONG |
| 832 | 7/8\" Dia 130 MM LONG |
| 833 | Supply of following STUD BOLT,ASTM A193 Gr.B8M CL.2, ASME B18.2.1, MTE |
| 834 | 1/2\" Dia 65 MM LONG |
| 835 | 1/2\" Dia 75 MM LONG |
| 836 | 5/8\" Dia95 MM LONG |
| 837 | 5/8\" Dia100 MM LONG |
| 838 | Supply of following STUD BOLT,ASTM A193 Gr.B3M, ASME B18.2.1, MTE |
| 839 | 1/2\" Dia 65 MM LONG |
| 840 | 1/2\" Dia 75 MM LONG |
| 841 | 3/4\" Dia120 MM LONG |
| 842 | 5/8\" Dia95 MM LONG |
| 843 | 5/8\" Dia85 MM LONG |
| 844 | 5/8\" Dia100 MM LONG |
| 845 | Supply of Deluge Valve System |
| 846 | 150 NB Deluge Valve Assembly |
| 847 | Supply of Ni-Al Bronze deluge valve system including its pnuematic trim and DV shall be auto reset type. Each Deluge valve system shall consist of following: |
| 848 | Pneumatically actuated flange type Ni-Al Bronze deluge valves suitable for seawater application |
| 849 | 15 NB Gunmetal Non-return valve Spring loaded suitable for pneumatic application 10.5 kg/Sq-cm rating. |
| 850 | 15 NB SS/GI heavy grade pipe alongwith forged screwed elbows, unions and other fittings for Trim assembly |
| 851 | Deluge valve trims, Test & drain trims, pneumatic trims, 15 NB ball valve sets for local operation of Deluge valve. |
| 852 | Pressure gauge with 6\" Dial Size with SS needle valve with necessary fittings & mountin0-07 kg/cm2 range (for air) - 1 No.0-15 kg/cm2 pressure range (for water - 1 No.) |
| 853 | Supply & fixing of 3 Nos. 1/2\" NPT (F) needle valve in instrument box for mounting 2 Nos. pressure transmitters and1 No. ofsoleNoid valve. |
| 854 | Supply of 2 Nos. pressure transmitters and1 No. ofsoleNoid valve. |
| 855 | 15 mm SS pipe, Heavy duty with required forged screwed fittings as required. |
| 856 | Air filter regulator |
| 857 | Water motor gong along with inlet strainer, 25 NB piping and outlet pipe of 3 meter. |
| 858 | Orifice plate of required size & fittings |
| 859 | Item includes installation and assembly of thedeluge valve with the above mentioned components, supply of material, welding, making flange connections using gaskets(with 200% gaskets SPARE QUANTITY), studs-nuts & washers and necessary couplings, clamps and similar items as may be required including making connection with hydrant net work. |
| 860 | Supply of MVW Spray System |
| 861 | Medium Velocity Water Spray NozzleType: Open & Non-clogOrifice Size: 1/2\" (M)Body Material: Al-BronzeNozzle K-factor: LaterSpray Angle: LaterUL Listed |
| 862 | Quartzoid Bulb (QB) DetectorType: PendantResponse: Standard ResponseBody Material: Forged BrassEnd Connection: 1/2\" (M)Temperature Rating: 79 Deg CUL Listed |
| 863 | SECTION 5 : CONTROL AND INSTRUMENTATION |
| 864 | Supply of Field Instruments |
| 865 | Pressure transmitter |
| 866 | Pressure transmitterwith SIL 2 rating |
| 867 | Pressure Transmitter with Hastelloy C for fire water application |
| 868 | Pressure gauge |
| 869 | Pressure gauge wih Hastelloy C for fire water application |
| 870 | Temperature Element (RTD) with thermowell |
| 871 | Temperature Transmitter |
| 872 | Temp gauge with theromowell |
| 873 | Dp type level transmitter |
| 874 | Level Transmitter GWR |
| 875 | Top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete |
| 876 | Orifice flow meter with DPT, Orifice plate, manifold etc. |
| 877 | Orifice flow meter with DPT, Orifice plate , manifold etc.Hastelloy C fire water application |
| 878 | Pressure switch Hastelloy C for fire water application |
| 879 | Pressure switch for potable water |
| 880 | 2\", 2 m3/hr, electromagnetic flow meter for portable water |
| 881 | Ultrasonic type flow transmitterfor portable water |
| 882 | Float typel level switch for portable water |
| 883 | Supply of Impluse tubing ,Fittings, Manifolds etc. |
| 884 | SS 316 Impluse tubing, fittings, Manifolds etcManifold 2 way SS316Manifold 5 way SS3161/2\"OD tube(5 mtr per instru)1/2\" SS Union Tee1/2\" OD x 1/2\" NPT male connector1/2\" ball valveNote: Refer P.011265-I-21003-001_Rev-A_Hook up installation Drawing, bidder shall evaluate quantity from drawing |
| 885 | Supply of GI perforated Cable trays along with cover |
| 886 | 50 mm (W) X 50 mm (H) |
| 887 | 100 mm (W) X 75 mm (H) |
| 888 | 300 mm (W) X 75 mm (H) |
| 889 | Supply of Penumatic pressure control valves with smart poisitioner |
| 890 | Control valve (2\") with smart positioner |
| 891 | Control valve (6-8\") with smart positioner |
| 892 | Supply of Junction boxes |
| 893 | Junction Box Ex proof with glands |
| 894 | Junction Box WP with glands |
| 895 | Supply of Instrumentation Cables |
| 896 | FRLS Instruments cables and power cable with cable glands for field instruments, MOV , control valves etc1P x 1.5mm2, 2P x 1.5 mm2, 6Px 1.5mm2, 12P x 1.5 mm2, 3C x 2.5 mm2, 12C x 1.5 mm2,1Q x 1.5. |
| 897 | Fire resistance Instruments cables and power cable with cable glands for gas detection, fire detection, valves ROSOV etc1P x 1.5mm2, 2P x 1.5 mm2, 6Px 1.5mm2, 12P x 1.5 mm2, 3C x 2.5 mm2, 1T x 1.5 mm2 and 12T x 1.5mm2 |
| 898 | Supply of Optical Fiber Cable |
| 899 | 24 Core Optical Fiber cable |
| 900 | Fiber terminal closure with pig tail |
| 901 | Inspection chember/ splicing chember |
| 902 | Joint closure/splice closure |
| 903 | electronic marker |
| 904 | Marker Locator |
| 905 | 50mm HDPE Duct along with fittings |
| 906 | Supply of Corrosion Monitoring system |
| 907 | CMS system with copoun, probe, barriers, access fittings, panel mounted indicator/receiver, copoun holder, service kit, Retriever kitNote: Refer Part 09: Instrumentation and Control Works (Technical specification and data sheets for all the instrumentation) |
| 908 | Supply of Metering system for POL and LPG Line |
| 909 | 12\" Coriolis flow meter skid with Flow computer, strainer Air eliminator,pressure transmitter, temperature transmitter with element and thermowell, skid valves, WCB piping & valve material for POL line |
| 910 | 10\" Coriolis flow meter skid with Flow computer, strainer Air eliminator,pressure transmitter, temperature transmitter with element and thermowell, skid valves, LTCS piping & valve material for LPG line |
| 911 | MFM Master flow meter skid with trolly for POL |
| 912 | Supply of Fire detection System |
| 913 | Controller with cabinet, Repeater panel |
| 914 | Multisensor (smoke & heat detectors) |
| 915 | smoke detectors |
| 916 | Response indicator |
| 917 | Manual call points Ex proof |
| 918 | Manual call points WP |
| 919 | Hooter & Beacon |
| 920 | Siren |
| 921 | Flame detectors |
| 922 | ESD Push Buttons |
| 923 | Exit Sign |
| 924 | 24 Hrs battery |
| 925 | Supply of Gas detection System |
| 926 | Controller with wall mounted cabinet |
| 927 | Open path gas detector with mounting stand with Ex Proof Loop indicator |
| 928 | Point gas detectors IR type with mounting stand |
| 929 | Calibration and alignment kit |
| 930 | Supply of Control & Monitoring system-SCADA SYSTEM incuding below equipment as per system architecture and tender specification at Jetty control building and 5 Acre Plot: |
| 931 | Server Sum Engineering work station/Operator work station with 20000 tags- 1 Nos |
| 932 | Operator Work station for Process control & monitoring system- 2 Nos |
| 933 | Operator Work station for safety control & monitoring system- 2 Nos |
| 934 | Process PLC with redundant processor, power supply along with cabinet wiring size 2100(H){2000+100 plinth} x800(D)x1000(W), colour RAL 7035- 1 Nos |
| 935 | ESD SIL -3 PLC with redundant processor, power supply along with cabinet wiring size 2100(H){2000+100 plinth} x800(D)x1000(W), colour RAL 7035 - 1 Nos |
| 936 | RTU cabinet wiring size 2100(H){2000+100 plinth} x800(D)x1000(W), colour RAL 7035- 1 Nos |
| 937 | Complete Furniture with chair at Jetty control room and 5 Acre plot as per control room layoutand consol drawing - Lot |
| 938 | Communication cable SCADA system- Lot |
| 939 | 24 Port LAN switch - 4 Nos |
| 940 | Alarm Annaciator- 1 Nos |
| 941 | Supply of SDH Telecommunication system as per below items and tender specification |
| 942 | SDH Equipment redundant STM -4 with two number addition STM-4 for further IOCL SCADA connectivity, 48 V DC PSU,cabinet etc. |
| 943 | EMS client & server , Cabinet mounted server,IT equipments with application software and 21\" monitor |
| 944 | Supply of CCTV System as per below items and tender specification |
| 945 | PTZ colour day/night cameras WP-IP 65 with POE and mounting poles -(Outdoor hazardous area) |
| 946 | Fix colour Cameras WP IP 65 with POE and mounting accessories- WP IP65 Fixed colour cameras (outdoor safe area) |
| 947 | Fix colour Cameras WP IP 65, Ex proof with POE and mounting accessoriers- (Outdoor hazardous area) |
| 948 | Video monitoring system(VMS) server with analytics software , Network video recorder (NVR)21\" Monitor , cabinet, mouse, joysticks,32 port LAN L2/L3 switch |
| 949 | Big screen 65\" |
| 950 | Optical cable,conduit, Ethernet cable, power cable , optical to ethernet converters long with cable laying, accessories as per site conditions. |
| 951 | Supply of EPABX System |
| 952 | IP EPABX 100 line equipment with CO cards, IP trunk line,PRI Line |
| 953 | Analog Phone |
| 954 | IP phone |
| 955 | Supply of PAGA System |
| 956 | PAGA system with central exchange, gooseneck station, controller,WP field call stations, flame proof call stations, interface with EPABX, cables and juncation box at Jetty and 5 acre plot |
| 957 | WP IP 54 horn loudspeaker with receiver handset- 3 Nos |
| 958 | WP IP 65 & Ex proof horn loudspeaker with receiver handset - 48 Nos |
| 959 | Indoor horn loudspeaker with receiver handset- 3 Nos |
| 960 | Indoor horn loudspeaker -11 Nos |
| 961 | Master control unit -1 Nos |
| 962 | Supply of Ship to Shore link |
| 963 | ESL link between ship and shore with controller with display cabinet |
| 964 | Supply of EX-Proof Mobile |
| 965 | Ex proof mobile phone for hzardous area communication |
| 966 | Supply of Walky-Talky including below equipments and cables |
| 967 | Base station- 3 Nos |
| 968 | RepNoter station-2 Nos |
| 969 | Ex Proof Handsets- 15 Nos |
| 970 | Handset charger- 2 Nos |
| 971 | softwareLicense charges-1 Nos |
| 972 | Supply of Access Control system including below equipments and cables |
| 973 | Access Contoller |
| 974 | Client Operator work station |
| 975 | Proximity card reader entry |
| 976 | Proximity card reader for exit |
| 977 | Exit push button |
| 978 | Electro-magnetic door lock |
| 979 | Battery |
| 980 | Surge relief skid along with surge relief valves, nitrogen cylinders, control panel, pressure transmitter, pressure gauge, flow switches, isolation valves and material test certificates for 1 Nos each for POL and LPG line. |
| 981 | SECTION 6 : HVAC |
| 982 | Supply of HVAC System of Control Building at Jetty area |
| 983 | Supply of wall mounted air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 984 | Split AC units located at Cabin-1:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 985 | Split AC units located at UPS room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 986 | Split AC units located at Laboratory:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 987 | Split AC units located at Office:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 988 | Supply of ceiling mountedcassette type air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 989 | Split AC units located at Custom room:Total cooling capacity: 3.0 TRDehumidified air quantity: 1650 CMH |
| 990 | Split AC units located at Control room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1250 CMH |
| 991 | Split AC units located at Equipment room:Total cooling capacity: 3.0 TRDehumidified air quantity: 1650 CMH |
| 992 | Split AC units located at Office:Total cooling capacity: 2.0 TRDehumidified air quantity: 1250 CMH |
| 993 | Supply of fan filter unit located at Transformer & Switchgear room:The supply fan-filter unit shall consist of wall mounted tube axial flow fan, drive motor, Inlet Louver, pre-filter, supply cowl with protective wire netting inside the room, supports and supporting structures, nuts and bolts, vibration isolators.Fan capacity: 10000 CMHStatic pressure: 20 mmWG |
| 994 | Back draft damper located at Transformer & Switchgear room:The wall mounted back draft damper shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1450 mm x 550 mm |
| 995 | Transfer air grille located at Transformer & Switchgear room:The wall mounted transfer air grille shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1450 mm x 550 mm |
| 996 | Supply of Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. |
| 997 | Exhaust fan located at DG room:Fan capacity: 8000 CMHStatic pressure: 8 mmWG |
| 998 | Exhaust fan located at Air compressor room:Fan capacity: 6500CMHStatic pressure: 8 mmWG |
| 999 | Exhaust fan located at Battery room:Wall mounted Exhaust fan shall consist of bifurcated type axial flow fan, drive motor (flame proof type), protective wire netting inside the room, gravity louver at fan outlet, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. All parts of this system coming in contact with acid fumes shall be epoxy painted.Fan capacity: 1500 CMHStatic pressure: 10 mmWG |
| 1000 | Supply of wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G. |
| 1001 | Intake louver located at DG room:Size: 1750 mm x 550 mm |
| 1002 | Intake louver located at Air compressor room:Size: 850 mm x 550 mm |
| 1003 | Intake louver located at Battery room:Size: 750 mm x 450 mm |
| 1004 | Intake louver located at Laboratory:Size: 750 mm x 450 mm |
| 1005 | Supply of Wall mounted propeller fan shall consist of propeller fan, drive motor, gravity louver at fan outlet, supports, nuts and bolts, vibration isolators etc. |
| 1006 | Propeller type exhaust fan located at BCW toilet:Fan capacity: 450 CMHStatic pressure: 4 mmWG |
| 1007 | Propeller type exhaust fan located at BCW WC:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1008 | Propeller type exhaust fan located at Toilet:Fan capacity: 550 CMHStatic pressure: 4 mmWG |
| 1009 | Propeller type exhaust fan located at Laboratory:Fan capacity: 1000 CMHStatic pressure: 6 mmWG |
| 1010 | Duct mounted In-line centrifugal / axial flow exhaust fan located at Pantry:Duct mounted In-line centrifugal / axial flow exhaust fan shall consist of fan, drive motor, ducting with grille, supports, nuts and bolts, vibration isolators etc.Fan capacity: 200 CMHStatic pressure: 5 mmWG |
| 1011 | Supply of HVAC system of Fire water pump house at Jetty area |
| 1012 | Exhaust fan located at Fire water pump house:Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc.Fan capacity: 10000 CMHStatic pressure: 8 mmWG |
| 1013 | Intake louver located at Fire water pump house:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1800 mm x 600 mm |
| 1014 | Supply of HVAC system of Electrical cum Control Building at 5 Acre Plot |
| 1015 | The wall mounted air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 1016 | Split AC units located at Equipment room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 1017 | Split AC units located at Control room:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 1018 | Split AC units located at Work station area:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 1019 | Split AC units located at Waiting room:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 1020 | Split AC units located at Meeting room:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 1021 | Supply offan-filter unit shall consist of wall mounted tube axial flow fan, drive motor, Inlet Louver, pre-filter, supply cowl with protective wire netting inside the room, supports and supporting structures, nuts and bolts, vibration isolators. |
| 1022 | Supply fan filter unit located at Transformer & PMCC room:Fan capacity: 5000 CMHStatic pressure: 20 mmWG |
| 1023 | Supply fan filter unit located at MV Switchgear room:Fan capacity: 5000 CMHStatic pressure: 20 mmWG |
| 1024 | Supply of wall mounted back draft damper shall be made galvanized steel of frame thickness 16G & Blade thickness 18G. |
| 1025 | Back draft damper located at Transformer & PMCC room:Size: 800 mm x 500 mm |
| 1026 | Back draft damper located at Transformer & PMCC room:Size: 650 mm x 300 mm |
| 1027 | Back draft damper located at MV Switchgear room:Size: 650 mm x 500 mm |
| 1028 | Exhaust fan located at Battery room:Wall mounted Exhaust fan shall consist of bifurcated type axial flow fan, drive motor (flame proof type), protective wire netting inside the room, gravity louver at fan outlet, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. All parts of this system coming in contact with acid fumes shall be epoxy painted.Fan capacity: 2000 CMHStatic pressure: 10 mmWG |
| 1029 | Intake louver located at Battery room:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 750 mm x 450 mm |
| 1030 | Supply of Wall mounted propeller fan shall consist of propeller fan, drive motor, gravity louver at fan outlet, supports, nuts and bolts, vibration isolators etc. |
| 1031 | Propeller type exhaust fan located at Guard toilet:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1032 | Propeller type exhaust fan located at Store:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1033 | Propeller type exhaust fan located at Gents Toilet:Fan capacity: 400 CMHStatic pressure: 4 mmWG |
| 1034 | Supply of HVAC system of Warehouse at 5 Acre Plot |
| 1035 | Exhaust fan located at Warehouse:Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc.Fan capacity: 2500 CMHStatic pressure: 8 mmWG |
| 1036 | Intake louver located at Warehouse:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 750 mm x 450 mm |
| 1037 | Supply of HVAC system of Box Culvert |
| 1038 | The cabinet type supply fan-filter unit shall consist of direct driven / belt driven centrifugal flow fan, drive motor, Inlet Louver, pre-filter, VCD at fan outlet, supports and supporting structures, nuts and bolts, vibration isolators. The fan outlet shall be connected to ducting system.Fan capacity: 24000 CMHStatic pressure: 33 mmWG |
| 1039 | TheRoof Extractor shall consist of roof mounted axial flow exhaust fan, drive motor, rain protection hood with bird screen, supports & supporting structure, grouting frame, bolts, nuts, transition piece (if required), vibration isolators, water sealing arrangement at the base and inspection door. The fan inlet shall be connected to ducting system.The exhaust fan shall be spark proof construction & motor shall be flame proof type.Fan capacity: 24000 CMHStatic pressure: 22 mmWG |
| 1040 | Supply of HVAC items for duct works |
| 1041 | Supply of Ducting: Ductingshall be made of G.I. sheet of at least grade 180 as per IS 277. Specified quantity is indicative only. Bidder shall estimate the final quantity & quote the ducting quantity, hanger support etc. according to \"Air conditioning & Ventilation layout of Control Building (Dwg. No. P.011265-M-21006-502)\" and \"Ventilation layout of Box Culvert (Dwg. No. P.011265-M-21006-505)\". |
| 1042 | 18G |
| 1043 | 20G |
| 1044 | 22G |
| 1045 | 24G |
| 1046 | Supply air Grille: The supply air grille shall be made up of Aluminium construction and painted with two (2)coats of powder coating paints. Supply air grille shall be provided with volume control damper. The grille frame and louvers shall be manufactured of at least 20G and 22G respectively. |
| 1047 | Size: 800 x 300 |
| 1048 | Supply of Return air Grille: The return air grille shall be made up of Aluminium construction and painted with two (2)coats of powder coating paints. Return air grille shall be provided without volume control damper. The grille frame and louvers shall be manufactured of at least 20G and 22G respectively. |
| 1049 | Size: 600 x 300 |
| 1050 | Size: 300 x 300 |
| 1051 | Supply of Flexible connection: Flexible connectionshall be fire retardant type. Flexible connections of at least 150 mm length shall be provided at each connection between ductwork and fan units. Thequantity shall be estimated according to \"Air conditioning & Ventilation layout of Control Building (Dwg. No. P.011265-M-21006-502)\" and \"Ventilation layout of Box Culvert (Dwg. No. P.011265-M-21006-505)\". |
| 1052 | PART B - INSTALLATION / ERECTION, TESTING AND COMMISSIONING OF FOLLOWING ITEMS For all the items under Part B of this schedule, the rates to be quoted include:-(A)For all the items under Part B of this schedule, the rates to be quoted include charges towards Installation & Erection works including supply of all erection equipment & materials, tools, tackles and labour; (B) Cutting, aligning to plumb & levels, fabrication, welding, erection, etc. as per site requirements; Testing and Commissioning of all items / equipment as per attached specifications, data sheets, codes and directions of PMC Engineer/ Owner; Chipping of walls, drilling, making holes, patching up works with plastering including bringing the surfaces to original condition etc. |
| 1053 | SECTION 1 : MECHANICAL |
| 1054 | Marine Loading Arms |
| 1055 | Marine Loading Arm, Size 12\", 300#, Product: LPG (Propane & Butane), Material: LTCS, Electro-Hydraulic operated, including spare parts, Emergency Release Coupling and Hydraulic Quick Connect/ Disconnect Cargo Couplers. |
| 1056 | Marine Loading Arm, Size 12\", 300#, Product: POL (MS, HSD, ATF & SKO), Material: Carbon Steel, Electro-Hydraulic operated, including spare parts, Emergency Release Coupling and Hydraulic Quick Connect/ Disconnect Cargo Couplers. |
| 1057 | Hydraulic Power Unit (HPU) common for all MLAs |
| 1058 | Supervision Service |
| 1059 | Gangway Tower |
| 1060 | Hydraulic operated telescopic type Ship Access Gangway Tower with steel tower, platform, inclined ladder, bulwark ladder, hydraulic cylinder, HPU, typside jib crane with ground pendant switch control, combination starter, and all associated accessories.Upper Level: 19.5 m CDDown Level: 2.1 m C.DJib Crane Capacity: 2.5 MTMax./Min. Radius of Jib Crane: 19 m / 3.5 m |
| 1061 | Supervision Service |
| 1062 | Pig Launcher cum Receiver |
| 1063 | Bi-directional launcher cum receiver suitable for accomodating intelligent pigs & other cleaning / displacement / gauging pigs, fitted with Quick Opening End Closure (QOEC) suitable for horizontal installation including all accessories required to make Bi-Directional Launcher & Receiver system complete operational and QOEC shall be hand operated by a single lever operation and operable by one operator, including placement of perforated SS Tray inside the Bi-Directional Launcher & Receiver, mounting of Pig Signaller on the Bi-Directional launcher & receiver, Pig Handling (insertion / retraction) System includingmating flanges for all the flanged end Nozzle. Required studs, Nuts, bolts, Gaskets and erection of the following withfoundation Bolts and associated accessories including commissioning tha same etc. complete. |
| 1064 | Bi-directional Pig Launcher cum Receiver (of size 36\" x 30\" NB & ANSI Class 150) along with Quick Opening End Closure (QOEC), all required Nozzles, vent, drain, flanges, gaskets and bolting - 2 Nos. |
| 1065 | Non-intrusive type (Ultrasonic) Pig Signaller mounted on Pig Launcher cum Receiver- 2 Nos. |
| 1066 | Supply of Door Seal for Quick Opening End Closure (QOEC) [Commissioning Spares]- 4 Nos. |
| 1067 | Non-intrusive type (Ultrasonic) Pig Signaller mounted on 30\" NB Pipeline- 2 Nos. |
| 1068 | Jib Crane of capacity 3T to suit the pig handling for scrapper trap as specified above- 1 No. |
| 1069 | Pig Handling System with insertion / retraction facilities for inserting / pulling the SS Tray / Pigs to suit the scrapper trap- 2 Nos. |
| 1070 | EOT Crane (for Fire Water Pump House) |
| 1071 | 10T Capacity Double Girder EOT Crane incl. bridge structure, travelling mechanism, hoisting mechanism, service platform, brake mechanism, electric motors, trailing cables, AC variable frequency controls for all motions, lighting fixtures and all other necessary accessories.Building Span: 15.7 mBay Length: 44 mLifting Height: 6.4 mArea Classification: Non-HazardousOperation: Pendant + Radio Remote Control |
| 1072 | Slop Tanks |
| 1073 | Horizontal, cylindrical, pit mounted (below deck) POL Slop Tanks (one each for MS, HSD, ATF & SKO) incl. shell, flat ends, Nozzles, boot for slop pump mounting, manhole with davit arrangement, saddle supports, stiffener plates and RF pads, internal piping, earthing cleats, nameplates, anchor bolts etc.Design Standard: IS 10987 (latest edition)Internal Diameter: 2200 mmLength: 9000 mmMaterial: MS (IS 2062 Gr.B) |
| 1074 | Horizontal, cylindrical, pit mounted (below deck) POL Slop tank incl. shell, flat ends, Nozzles, boot for slop pump mounting, manhole with davit arrangement, saddle supports, stiffener plates and RF pads, internal piping, earthing cleats, nameplates, anchor bolts etc.Design Standard: IS 10987 (latest edition)Internal Diameter: 1700 mmLength: 8500 mmMaterial : MS (IS 2062 Gr.B) |
| 1075 | Slop Pumps |
| 1076 | Vertical, Extended Shaft, Submerged Sump Pump (VS-4) type vessel mounted slop pumps for POL products (one each for MS, HSD, ATF & SKO) including drive motor, coupling with coupling guard, common base frame for each pump and motor, complete sealing / cooling / lubrication system, counter flanges with bolts, nuts & gaskets, Local Control Panel (LCP) etc.Rated Flowrate: 36 m3/hr.TDH: 100 MLCMOC: ASTM A48 CL 30 (Casing) / ASTM A351 CF8 (Impeller) |
| 1077 | Vertical, Extended Shaft, Submerged Sump Pump (VS-4) type vessel mounted slop pumps including drive motor, coupling with coupling guard, common base frame for each pump and motor, complete sealing / cooling / lubrication system, counter flanges with bolts, nuts & gaskets, Local Control Panel (LCP) etc.Rated Flowrate: 10 m3/hr.TDH: 100 MLCMOC: ASTM A48 CL 30 (Casing) / ASTM A351 CF8 (Impeller) |
| 1078 | Instrument Air System |
| 1079 | Oil Flooded, Rotary Screw type Compressor complete with electric motor, common baseplate or skid for compressor with all components, individual suction air filters, oil filter, air cooled intercooler & aftercooler, Auto drain traps with bypass valve, safety valves, instruments & controls, microprocessor based local control unit for each compressor etc.Capacity (each) / FAD : 200 Nm3/hr. (incl. purge air loss)Guaranteed output at package outlet terminal point : 170 Nm3/hr.Discharge Pressure at package outlet: 7 barg |
| 1080 | Vertical, cylindrical, dished end type air receiver (one at compressor discharge and two at dryer discharge) complete with manhole, pressure indicators, temperature indicators, automatic drain trap, block valves for instruments, manual drain line with valve etc.Capacity of Compressed Wet Air Receiver : Bidder to decideCapacity of each Instrument Dry Air Receiver : 5 m3MOC: IS 2002 Gr. 2A/2B or IS 2062 |
| 1081 | Heatless purge type air drier including twin towers with a pressure / temperature safety relief valve, pressure indicator, purge volume control valve, purge flow meter, silencer, thermostatic devices, dew point alarm and indication equipment, control and alarm circuit etc. Following items are also included:a) One (1) set of pre-filter for each drier including differential pressure indicator, automatic drain traps with bypass, and block valves for maintenanceb) One (1) set of After-filter for each drier including differential pressure indicator, alarm, automatic drain traps with bypass, and block valves for maintenancec) One (1) relay based control system for Air Drier |
| 1082 | Erection, Testing & Commissioning of all integral piping including necessary internal pipes, fittings, instruments, drains and vents with isolation valve, supports within package unit |
| 1083 | Vapour Eliminators |
| 1084 | Vertical, Cylindrical type Vapour Eliminators to separate any carry over liquid in the incoming nitrogen gas supply including all necessary accessories.Design Pressure: 6 bargMOC: Carbon Steel (ASTM A516 Gr.70)Dimension (Approx.): 2 m (Dia) x 3.5 m (Height)Inlet: 16\"Vapour Outlet: 10\" |
| 1085 | Flame Arresters |
| 1086 | Vertical, inline Flame Arrestor Assembly complete with all necessary accessories (Suitable for Zone 2 Gas Group IIA/IIB, Temperature Class: T3) : |
| 1087 | 10\", 150#, MOC: Carbon Steel (Body) / Flame Element (SS 316L) |
| 1088 | 2\", 150#, MOC: Carbon Steel (Body) / Flame Element (SS 316L) |
| 1089 | Nitrogen System |
| 1090 | Nitrogen system comprising ofmodules of liquid Nitrogen storage tank with vaporisers as per Particular Technical Specification along with integral and interconnecting piping and instrumentation, civil foundations and installation cost. |
| 1091 | SECTION 2 : PIPING |
| 1092 | Welding, testing and commissioning of Carbon steel/ Stainless steel MOVs/ GATE VALVE/ GLOBE VALVE/ NRV/ ROSOV/ DBBV/ BALL VALVES/ ARC VALVE/ DELUGE VALVE/ BUTTERFLY VALVE/ PUPPET VALVES/ AIR RELEASE VALVE/ STRAINER, etc. on the pipeline including supplying and fixinggaskets, studs, nutswashers of approved make, all leads & lifts etc., complete as per specifications and instructions of PMC Engineer/ Owner.Note: a) Rate includes painting with approved make, colour, shade including colour coding as per specifications.b) Rate includes providing 8 SWG bare Cu wire for bonding between flanges for sizes for all Product pipelines |
| 1093 | Erection, Testing & Commissioning the following sizes of CS Manual Ball Valves (ASTM A105 flanged # 800 ) as per Specification |
| 1094 | 15 mm dia |
| 1095 | 25 mm dia |
| 1096 | 50 mm dia |
| 1097 | Erection, Testing & Commissioning the following sizes of CS Manual Ball Valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 1098 | 100 mm dia |
| 1099 | 150 mm dia |
| 1100 | 200 mm dia |
| 1101 | 250 mm dia |
| 1102 | 300 mm dia |
| 1103 | Erection, Testing & Commissioning the following sizes of CS Manual Globe Valves (ASTM A105 flanged # 800 ) as per Specification |
| 1104 | 25 mm dia |
| 1105 | Erection, Testing & Commissioning the following sizes of CS Manual Globe Valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 1106 | 200 mm dia |
| 1107 | 250 mm dia |
| 1108 | Erection, Testing & Commissioning the following sizes of CS Manual Globe Valves (ASTM A 352 Gr. LCB flanged # 800 ) as per Specification |
| 1109 | 25 mm NB |
| 1110 | Erection, Testing & Commissioning the following sizes of CS Manual Ball Valves (ASTM A 352 Gr. LCB flanged # 150 ) as per Specification |
| 1111 | 50 mm NB |
| 1112 | Erection, Testing & Commissioning the following sizes of CS Manual Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 1113 | 50 mm NB |
| 1114 | Erection, Testing & Commissioning the following sizes of SS Manual Ball Valves (ASTM A182 Gr. F316L flanged # 150 ) as per Specification |
| 1115 | 25 mm NB |
| 1116 | Erection, Testing & Commissioning the following sizes of SS Manual Globe Valves (ASTM A182 Gr. F316L flanged # 800 ) as per Specification |
| 1117 | 25 mm NB |
| 1118 | Erection, Testing & Commissioning the following sizes of SS Manual Ball Valves (ASTM A351 GR CF3 flanged # 150 ) as per Specification |
| 1119 | 50 mm NB |
| 1120 | Erection, Testing & Commissioning the following sizes of SS Manual Globe Valves (ASTM A351 GR CF3 flanged # 150 ) as per Specification |
| 1121 | 50 mm NB |
| 1122 | Erection, Testing & Commissioning the following sizes of CS Check Valves (ASTM A105 flanged # 800 ) as per Specification |
| 1123 | 25 mm NB |
| 1124 | Erection, Testing & Commissioning the following sizes of CS Check Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 1125 | 50 mm dia |
| 1126 | 100 mm dia |
| 1127 | 200 mm dia |
| 1128 | 300 mm dia |
| 1129 | 600 mm dia |
| 1130 | Erection, Testing & Commissioning the following sizes of CS Excess Flow Check Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 1131 | 300 mm dia |
| 1132 | Erection, Testing & Commissioning of Thermal relief valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 1133 | 25mm X 50mm dia TRV |
| 1134 | Erection, Testing & Commissioning of Thermal relief valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 1135 | 25mm X 50mm dia TRV |
| 1136 | Erection, Testing & Commissioning of Pressure relief valves (ASTM A 216WCB flanged # 150 ) as per Specification |
| 1137 | 50mm X 50mm dia SRV |
| 1138 | 100mm X 150mm dia SRV |
| 1139 | Erection, Testing & Commissioning the following sizes of CS Motor Operated Ball Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 1140 | 50 mm dia |
| 1141 | 100 mm dia |
| 1142 | 150 mm dia |
| 1143 | 400 mm dia |
| 1144 | 600 mm dia |
| 1145 | 750 mm dia |
| 1146 | Erection, Testing & Commissioning the following sizes of CS Motor Operated Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 1147 | 300 mm dia |
| 1148 | 450 mm dia |
| 1149 | 600 mm dia |
| 1150 | Erection, Testing & Commissioning the following sizes of CS Motor Operated Globe Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 1151 | 600 mm dia |
| 1152 | Erection, Testing & Commissioning the following sizes of CS Electro Hydraulic Butterfly Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 1153 | 600 mm dia |
| 1154 | Erection, Testing & Commissioning the following sizes of CS Pneumatic Control Globe Valves (ASTM A216WCB flanged # 150 ) as per Specification |
| 1155 | 250 mm dia |
| 1156 | 500 mm dia |
| 1157 | Erection, Testing & Commissioning the following sizes of CS Pneumatic Control Ball Valves (ASTM A 352 Gr. LCB flanged # 300 ) as per Specification |
| 1158 | 300 mm dia |
| 1159 | Welding and laying of Above GroundProductSteel Pipelines on pipeline trestle/ pedastals/sleepers/overhead pipe rack/structures/within culvert, etc. The pipeline laying includes cutting, beveling, positioning, setting, fixing the pipe fittings, such as, elbows, bends tees, reducers, etc., complete with supports as per drawings and hydro testing the pipelines as per specifications.Note: a. Welding of pipeline should conformto Radiography quality. b. Pipe length indicated against each size is actual as per drawing. Payment will be made for the actual quantity executed at site. c. Pipe fittings shall form the part of the measured length of pipeline. No additional payment shall be made for erection/ installation of pipe fittings.d. Pipeline colour coding shall be carried out as per IOC specifications at No extra cost for product piping. |
| 1160 | Erection, Welding, Testing & Commisioning of CS Seamless Pipes to API5L Gr.X52, Dim. ASME B36.10 |
| 1161 | 750mm NB SCH THK. 10.3mm Bevel ends |
| 1162 | Erection, Welding, Testing & Commisioning of CS Seamless Pipes to ASTM A106 Gr.B, Dim. ASME B36.10 |
| 1163 | 25mm NB SCH S-80 Plain ends |
| 1164 | 50mm NB SCH S-80 Bevel ends |
| 1165 | 80mm NB SCH S-STD Bevel ends |
| 1166 | 100mm NB SCH S-STD Bevel ends |
| 1167 | 150mm NB SCH S-STD Bevel ends |
| 1168 | 200mm NB SCH S-STD Bevel ends |
| 1169 | 250mm NB SCH S-STD Bevel ends |
| 1170 | 300mm NB SCH S-STD Bevel ends |
| 1171 | 400mm NB SCH S-STD Bevel ends |
| 1172 | 500mm NB SCH S-STD Bevel ends |
| 1173 | 600mm NB SCH S-STD Bevel ends |
| 1174 | Erection, Welding, Testing & Commisioning of CS Seamless Pipes to ASTM A333 Gr.6, Dim. ASME B36.10 |
| 1175 | 25mm NB SCH S-160 Plain ends |
| 1176 | 450mm NB SCH S-30 Bevel ends |
| 1177 | 300mm NB SCH S-40 Bevel ends |
| 1178 | 50mm NB SCH S-80 Bevel ends |
| 1179 | Erection, Welding, Testing & Commisioning of CS Galvanized Seamless Pipes to ASTM A106 Gr.B, Dim. ASME B36.10 |
| 1180 | 25mm NB SCH S-80 MTE |
| 1181 | 25mm NB SCH S-80 PE X MTE 100 mm Long |
| 1182 | 50mm NB SCH S-STD Bevel Ends |
| 1183 | 80mm NB SCH S-STD Bevel Ends |
| 1184 | Erection, Welding, Testing & Commisioning of SSSeamless Pipes to ASTM A312 Gr.TP316L, Dim. ASME B36.19 |
| 1185 | 50mm NB SCH S-40S Bevel Ends |
| 1186 | 25mm NB SCH S-40S Plain Ends |
| 1187 | 25mm NB SCH S-40S Plain Ends X MTE 100 mm LONG |
| 1188 | Supplying & application of painting of piping after surface prepartion by grit blasting -SA 2- 1/2.Primer: Self priming surface tolerant Polyamine/ Amide cured HB modified Aluminium filled Epoxy Mastic Primer. 100 micron.Intermediate coat: Glass flakes coating with resin/ medium as liquid Epoxy cured with Polyamine/ Amide/ Amino-amide or Isophthalic Polyster/ Acrylic Copolymer. 200 micronFinish coat: Two components Aliphatic Acrylic re- coatable Polyurethane. 2 x 35 micron= 70 micron. |
| 1189 | Supplying and Erection of Insulation for the following above ground Propane/Butanepipelines withinsulation of 200 mm thickness (100 mm Preformed PIR followed by 100 mm cast-insiitu PIR) and the final layer shall be finished with 0.4mm thick SS-316 sheet as per the Technical specifications and datasheet. |
| 1190 | 450 mm dia |
| 1191 | 300 mm dia |
| 1192 | 100 mm dia |
| 1193 | 50 mm dia |
| 1194 | Supplying and Erection of High Density PUF support block for 450 mm dia / 300 mm dia Propane/ Butane Pipelines with insulation thickness of 200 mm * 400 mm long of density 250 kg/m3 and supplied in two half sections including any mechanical clamp/ steel part, etc. complete as per specifications and datasheet. |
| 1195 | 450 mm dia |
| 1196 | 300 mm dia |
| 1197 | Supply, Fabrication and Erection Of Structural Steel (Including Cradle Supports, U Bolts, Structural Supports, Embedded Steel Etc.) |
| 1198 | U-Bolt |
| 1199 | 15 mm dia |
| 1200 | 25 mm dia |
| 1201 | 50 mm dia |
| 1202 | 80 mm dia |
| 1203 | 100 mm dia |
| 1204 | TEFLON PAD ASSEMBLY |
| 1205 | SUPPLY OF SPECIALITIES |
| 1206 | SUPPLY & INSTALLATION OF SAFETY SHOWER/ EYEWASH UNIT (as per IS 10592) |
| 1207 | ORIFICE PLATE 3MM & 6MM #300, |
| 1208 | 80 mm dia |
| 1209 | 100 mm dia |
| 1210 | SPECTACLE BLIND |
| 1211 | 25 mm dia |
| 1212 | 50 mm dia |
| 1213 | 80 mm dia |
| 1214 | 100 mm dia |
| 1215 | Flow Tee ASTM A234 Gr.WPB (Pipe Material API5L Gr.X52 |
| 1216 | DN 750 X DN 600 10.3mm THK X STD |
| 1217 | RADIOGRAPHY :- Performance of radiographic inspection on Piping of following Sizes & thicknesses including providing or hiring of all necessary equipments andpersonnels, etc. even though not expressly mentioned but required to perform the work as per specifications and instructions of PMC Engineer/ Owner. Radiographs shall be submitted to the PMC Engineer/ Owner. (Repeat Radiography due to defective radiograph on repaired joints due to Contractor\"s fault and for additional radiography necessitated due to poor performance of contractor\"s welders shall be done at contractor\"s cost) Note: Unit for Radiography quantity is \"Nos of each circumferencial weld joints\" in the pipes. |
| 1218 | 100mm NB |
| 1219 | 150mm NB |
| 1220 | 200mm NB |
| 1221 | 250mm NB |
| 1222 | 300mm NB |
| 1223 | 400mm NB |
| 1224 | 450mm NB |
| 1225 | 500mm NB |
| 1226 | 600mm NB |
| 1227 | 750mm NB |
| 1228 | Welding flanges of the following sizes on the Product pipelines including positioning, setting, welding with min. three runs outside and all leads & lifts etc., complete as per specifications and instructions at site. Radiography will be done for 10% of joints for which payment will made under separate item. |
| 1229 | Welding of following Socket Weld type- SWRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 1230 | 25mm NB |
| 1231 | 50mm NB |
| 1232 | Welding of following Socket Weld type- SWRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 1233 | 25mm NB |
| 1234 | Welding of following Weld neck type- WNRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 1235 | 80mm NB SCH S-STD |
| 1236 | 100mm NB SCH S-STD |
| 1237 | 150mm NB SCH S-STD |
| 1238 | 200mm NB SCH S-STD |
| 1239 | 250mm NB SCH S-STD |
| 1240 | 300mm NB SCH S-STD |
| 1241 | 400mm NB SCH S-STD |
| 1242 | 500mm NB SCH S-STD |
| 1243 | 600mm NB SCH S-STD |
| 1244 | Welding of following Weld neck type- WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 150 |
| 1245 | 50mm NB SCH S-80 |
| 1246 | Welding of following Weld neck type- WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 1247 | 450mm NB SCH S-30 |
| 1248 | 300mm NB SCH S-40 |
| 1249 | 50mm NB SCH S-80 |
| 1250 | Welding of following Weld neck type- WNRF 125 AARH as per ASTM A 694 Gr. F52 DIM. ASME B16.47 Series B Class 150 |
| 1251 | 750mm NB SCH THK. 10.3mm |
| 1252 | Welding of following Slip On type- SORF 125 AARH as per ASTM A105 (GALV.) DIM. ASME B16.5 Class 150 |
| 1253 | 50mm NB SCH S-STD |
| 1254 | 80mm NB SCH S-STD |
| 1255 | Welding of following Weld neck type- WNRF 125 AARH as per ASTM A182-F316L DIM. ASME B16.5 Class 150 |
| 1256 | 50mm NB SCH S-40S |
| 1257 | Making flanged joints (both for flanges & blind flanges) of the following sizes including supplying and fixing 3 mm thk Spiral Wound & Graphite Filled Metallic gaskets, studs, nuts, washers of approved make, all leads & lifts etc., complete as per specifications and instructions at site for Product lines & AFFF Pipe joints.Note:a. Item includes providing 8 SWG bare Cu wire for bonding between flanges for sizes up to & including 100 mm dia for Product pipelines |
| 1258 | Making Joints of following Socket Weld type- SWRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 1259 | 25mm NB |
| 1260 | 50mm NB |
| 1261 | Making Joints of following Socket Weld type- SWRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 1262 | 25mm NB |
| 1263 | Making Joints of following Weld neck type- WNRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 |
| 1264 | 80mm NB SCH S-STD |
| 1265 | 100mm NB SCH S-STD |
| 1266 | 150mm NB SCH S-STD |
| 1267 | 200mm NB SCH S-STD |
| 1268 | 250mm NB SCH S-STD |
| 1269 | 300mm NB SCH S-STD |
| 1270 | 400mm NB SCH S-STD |
| 1271 | 500mm NB SCH S-STD |
| 1272 | 600mm NB SCH S-STD |
| 1273 | Making Joints of following Weld neck type- WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 150 |
| 1274 | 50mm NB SCH S-80 |
| 1275 | Making Joints of following Weld neck type- WNRF 125 AARH as per ASTM A350 Gr.LF2 DIM. ASME B16.5 Class 300 |
| 1276 | 450mm NB SCH S-30 |
| 1277 | 300mm NB SCH S-40 |
| 1278 | 50mm NB SCH S-80 |
| 1279 | Making Joints of following Weld neck type- WNRF 125 AARH as per ASTM A 694 Gr. F52 DIM. ASME B16.47 Series B Class 150 |
| 1280 | 750mm NB SCH THK. 10.3mm |
| 1281 | Making Joints of following Slip On type- SORF 125 AARH as per ASTM A105 (GALV.) DIM. ASME B16.5 Class 150 |
| 1282 | 50mm NB SCH S-STD |
| 1283 | 80mm NB SCH S-STD |
| 1284 | Making Joints of following Weld neck type- WNRF 125 AARH as per ASTM A182-F316L DIM. ASME B16.5 Class 150 |
| 1285 | 50mm NB SCH S-40S |
| 1286 | SECTION 3 - ELECTRICAL |
| 1287 | 2 POLE STRUCTURE: 2 pole Structure including RSJs, ISMCs for 11 kV Incoming Power Supply with Gang operated isolator, D.O. fuse with base, lightning arrestors, earthing, padlocking for 2 Pole structure as per attached specification, data sheet including supply of commissioning spares, as required. |
| 1288 | Installation, Testing and Commissioning of trivector meter for tariff metering including metering enclosure.Note: The TVM shall be supplied by TANGEDCO. |
| 1289 | HT Switchboard : |
| 1290 | 11 kV, 630 A, 3 phase, 3 wire, 25 kA for 1 sec. rated switchgear with all accessories as per single line diagram, specification and data sheet as attached with the tender document. |
| 1291 | 11 kV, 630 A, 3 phase, 3 wire, 25 kA for 1 sec. rated single VCB cubicle (ICOG type panel) with all accessories as per single line diagram , specification and data sheet as attached with the tender document. |
| 1292 | Distribution Transformer : Distribution / Lightingtransformer of the following ratings as per attached specification, data sheetincluding supply of commissioning spares, as required. |
| 1293 | 200 kVA, 11/0.433 kV dry type transformer with all fittings and accessories as per specificationLocation: 5 acre plot substation room |
| 1294 | 630 kVA, 11/0.433 kV dry type transformer with all fittings and accessories as per specificationLocation : Substation room at jetty control building |
| 1295 | DG Set : |
| 1296 | 125 kVA, 415 V, 3 phase, 0.8 PF DG Set & AMF Panel with all fittings and accessories like lube oil system, cooling system, diesel oil system, all required piping, exhaust piping & support structure, day oil tank each along with all pipings with magnetic level switch,inter connecting cables and cable accessories, base channels etc. as per attached specification, data sheet & SLD including supply of commissioning spares, as required, First filling of engine oil, lubricant etc. The supply includes Residential silencer & spark arrestor.Location: DG Shed of 5 acre plot |
| 1297 | 600 KVA, 415V, 3 phase, 0.8 PF DG Set & AMF Panel complete with all required accessories like lube oil system, cooling system, diesel oil system, all required piping, day oil tank along with all pipings with magnetic level switch,inter connecting cables and cable accessories, base channels etc. as per attached specification, data sheet & SLD including supply of commissioning spares, as required, First filling of engine oil, lubricant etc. The supply includes Residential silencer & spark arrestor. Location: DG Room at jetty control building |
| 1298 | MV & LV Switch board/Panels/Sub Distribution Boards : |
| 1299 | EPMCC Panel: 415 V, 400 A, 3 phase, 4 wire, 25 kA for 1 sec. rated Onshore EPMCC with all accessories as per single line diagram, specification and data sheet.Location - 5 acre plot substation room |
| 1300 | EPMCC Panel: 415 V, 1250 A, 3 phase, 4 wire, 40 kA for 1 sec. rated Jetty EPMCC with all accessories as per single line diagram, specification and data sheet.Location - Substation room at jetty control building |
| 1301 | Onshore ACDB: 415 V, 100 A, 3 phase, 4 wire, 25 kA for 1 sec. rated Onshore ACDB with all accessories as per single line diagram, specification and data sheet.Location - 5 acre plot substation room |
| 1302 | Jetty ACDB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated Jetty ACDB with all accessories as per single line diagram, specification and data sheetLocation - Substation room at jetty control building |
| 1303 | MOV DB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated MOV DB with all accessories as per single line diagram, specification and data sheetLocation - Substation room at jetty control building |
| 1304 | HVAC DB: 415 V, 200 A, 3 phase, 4 wire, 40 kA for 1 sec. rated HVAC DB with all accessories as per single line diagram, specification and data sheetLocation - Substation room at jetty control building |
| 1305 | APFC Panel: 25 kVAR, 415 V Capacitor bank with APFC as per specification, data sheet and single line diagramLocation - Substation room at jetty control building |
| 1306 | Lighting Distribution Board & Lighting Panel : |
| 1307 | LDB: 415 V, 63 A, 3 phase, 4 wire, 10 kA for 1 sec. rated onshore area lighting DB with 25 kVA 0.415/0.433 kV lighting transformer and with all accessories as per specification. Incomer: 63 A, 3 phase, 1 No. Outgoing: 32 A, 3 phase, 6 Nos..Location - 5 acre plot substation room |
| 1308 | LDB: 415 V, 100 A, 3 phase, 4 wire, 10 kA for 1 sec. rated jetty area lighting DB with 50 kVA 0.415/0.433 kV lighting transformer and with all accessories as per specification. Incomer: 100 A, 3 phase 1 No. Outgoing: 63 A, 3 phase 9 Nos.Location - Substation room at jetty control building |
| 1309 | LP: Indoor Non FLP type lighting panel as per specification with all accessories. Incomer: 32 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 6 Nos. |
| 1310 | LP: Indoor Non FLP type lighting panel as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 1311 | LP: Outdoor FLP type (Ex-d, IIA/IIB, T3) as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 1312 | LP: Outdoor Non FLP type as per specification with all accessories. Incomer: 63 A, 3 phase, 1 No.; Outgoing: 16 A, 1 phase, 9 Nos. |
| 1313 | UPS System : |
| 1314 | 2x100% 10 kVA, 240 V AC UPS with maintenance bypass and UPSDB for onshore area as per single line diagram, specification and data sheetLocation - 5 acre plot substation room |
| 1315 | 2x100% 20 kVA, 230 V AC UPS with maintenance bypass and UPSDB for Jetty area as per single line diagram, specification and data sheetLocation- Substation room at jetty control building |
| 1316 | BATTERY : |
| 1317 | Placing of cells on stand in proper sequence, cleaning of cells, making inter cell/ tier/ row connections, filling up with electrolyte, charging, testing & commissioning of BATTERY as per manufacturer\"s instructions and other associated work, labour & materials complete: |
| 1318 | VRLA SMF type Battery Bank suitable for 2x10 kVA UPS |
| 1319 | VRLA SMF type Battery Bank suitable for 2x20 kVA UPS |
| 1320 | LED Lighting Fixtures & Accessories : |
| 1321 | Weather proof Lighting Fixtures, Lamps & accessories as per specifications. (All Lighting fixtures shall be provided with required No. of double compression cable glands and stopper plugs as required including tinned copper cable lugs of suitable type for termination) |
| 1322 | Note: Rate to include mounting of light fixtures of all types on walls/ structural brackets/ high masts/ street light poles/ platforms/ lighting poles/ pendants and all similar such places;Supply & fixing pipes/ GI chains, neoprene/ rubber/ PVC bushes at fixtures and JBs; supply & fixing double compression cable glanding & termination using tinned copper lugs of suitable size & type, crimping of lugs & connections at fixtures/ control gears; Down rods with ball and socket arrangements as required; Fixing arrangements with anchor fasteners; supply of all erection materials including necessary accessories like chokes, starters, condensers, internal & external reflectors, igniter, canopy etc., complete as per drawings and documents, specifications, codes & standards and instructions/ directions of PMC Engineer/ Owner. |
| 1323 | 40W Linear LED Light (Bajaj Cat No.- BLTRU 40W VIVA or approved equivalent) |
| 1324 | 36W Planner Recess Mounting Type LED Light suitable for false celling ( Bajaj BCTBLR 36W LED or approved equivalent) |
| 1325 | 100W High bay LED Fitting (BAJAJ 13499 BGHB 100W future or approved equivalent) |
| 1326 | 3W Single Side Display LED EXIT with ARROW (with 2HR. Battery backup) |
| 1327 | 10W LED Suspended Mounting Weatherproof Bulkhead Luminaries(BAJAJ BIBWP 10W LED or approved equivalent) |
| 1328 | 20W LED surface mounted Normal Luminaries(PHILIPS SM134VPSD W60L60 or approved equivalent) |
| 1329 | 30W Peripheral LED Light (Bajaj Cat No.- BCLST 30W LED or approved equivalent) |
| 1330 | 100 W LED street light type fixture as per specification ( Bajaj Cat No.- BRTFG 100W LED I or approved equivalent) |
| 1331 | 120 W LED Flood Light (Bajaj Cat No- BAR FEG 120 W or approved equivalent) including all accessories |
| 1332 | Flame proof Lighting Fixture & Accessories |
| 1333 | 50W LED Well glass Light fittings ( Baliga Cat. No.-FLPW-1245L LED 50W or approved equivalent) |
| 1334 | 36 W surface mounted flameproof type LED fixture (NoTON cat. No.TFC 6135Z NoTON-TUFFLITE IP66 or approved equivalent) |
| 1335 | Other Lighting Material: |
| 1336 | 3 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of Engineer in Charge. |
| 1337 | 6 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of Engineer in Charge. |
| 1338 | 9 modular switch frame including 6A, 1 No. 3 pin socket, as per specifications and direction of Engineer in Charge. |
| 1339 | 30 m high mast lighting structure includingfoundation, fixingof base plate and complete erection, testing and commisioning |
| 1340 | 9 Mtr GI street Lighting Pole includingfoundation, fixingof base plate and complete erection, testing and commisioning |
| 1341 | 4.5 Mtr Swan Neck GI Lighting Pole includingfoundation, fixingof base plate and complete erection, testing and commisioning |
| 1342 | Heavy duty PVC Coduits - 19 mm for concelled wiring as per specification |
| 1343 | Heavy duty PVC Coduits - 25 mm for concelled wiring as per specification |
| 1344 | Rigid steel Coduits - 19 mm for exposed wiring for fire water pump house and wire house as per specification |
| 1345 | Rigid steel Coduits - 25 mm for exposed wiring for fire water pump house and wire house as per specification |
| 1346 | Flexible PVC conduit |
| 1347 | Flexible steel conduit |
| 1348 | 3 way Circular JB/pull box as per specification |
| 1349 | 4 way Circular JB/pull box as per specification |
| 1350 | GI/SS Prefabricated Ladder type and Perforated Type Cable Tray |
| 1351 | GI/SS prefabricated ladder type cable trays & their accessories (like tray cover, Coupler plate, Tray Fixing clamp, Fastener, nut, bolt washer etc. as required ) of following sizes as per drawing, data sheet. Rate shall include fixing of cable tray support also. |
| 1352 | 600 mm |
| 1353 | 300 mm |
| 1354 | 150 mm |
| 1355 | GI/SS prefabricated perforated type cable trays & their accessories( like tray cover, Coupler plate, Tray Fixing clamp, Fastener, nut, bolt washer etc. as required ) of following sizes as per drawing, data sheet. Rate shall include fixing of cable tray support also : |
| 1356 | 50 mm |
| 1357 | 150 mm |
| 1358 | 300 mm |
| 1359 | 600 mm |
| 1360 | Junction Box : |
| 1361 | Two way FLP type junction boxes as per specification including the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 1362 | Three way FLP type junction boxes as per specificationincluding the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 1363 | Four way FLP type junction boxes as per specification including the glands, lugs and terminal blocks of required cable size. (Max. incoming cable size 3.5Cx70 sq. mm, Max. outgoing Cable size 3Cx6 sq. mm ) |
| 1364 | Local Control Station : |
| 1365 | Flameproof (Ex’d’) Local Control Station with components as listed below and with Aluminium alloy (LM6 grade) enclosure as per Specification, Data Sheet and direction of Engineer-in-charge : |
| 1366 | With Start and Emergency Stop Push Button and Ammeter |
| 1367 | With Start and Emergency Stop Push Button |
| 1368 | Non FLP Local Control Station with components as listed below and with sheet steel enclosure as per Specification, Data Sheet and direction of Engineer-in-charge : |
| 1369 | With Start and Emergency Stop Push Button and Ammeter |
| 1370 | With Start and Emergency Stop Push Button |
| 1371 | FLP & Non FLP type Switch Socket & Plug : |
| 1372 | FLP Interlocking type switch sockets and plugs as per attached specifications & data sheets. All switch sockets shall be provided with 3mm thick FRP caNopy with side cover and FLP stopping plug as per specification and direction of PMC Engineer/ Owner : |
| 1373 | 415V, 3 phase 63A FLP switch socket and plug suitable for 3.5CX95 Sq.mm. cable entry |
| 1374 | 415V, 3 phase 63A Non FLP switch socket and plug suitable for 3.5CX95 Sq.mm. cable entry |
| 1375 | 240 V, 1 phase, 5/15A,FLP Switch Socket and plug and suitable for 3 C x 4 sqmm cable entry |
| 1376 | 240 V, 1 phase, 5/15A,Non FLP Switch Socket and plug and suitable for 3 C x 4 sqmm cable entry |
| 1377 | Ceiling Fan : |
| 1378 | 1200mm Sweep ceiling Fan with Down Rod |
| 1379 | Regulator for sweep ceiling Fan |
| 1380 | 900mm Sweep ceiling Fan with Down Rod |
| 1381 | 300mm Sweep Wall Fan |
| 1382 | HT/ LT Power and Control cables laying:Horizontal and Vertical Laying of FRLS, XLPE/ PVC cables on cable racks, trenches,directly buried; in floor slits; in G.I. conduit (including chipping of floor wherever required), cable risers, supports, hangers, saddles etc.; Laying through cable protection pipes; Sealing of wall and pipe openings and pipe sleeves, sand filling after cable layingetc. whereever required; cable clamps in vertical and horizontalruns;fixingof cable identification tags as per specifications; testing of cables before and after laying; installation of; Measurement of cables to be taken before cutting the cable from drum to avoid cable joint/ waste. Charges to include LT cable joints only if essential and unavoidable; Testing of cables and submission of megger reports for each run of cable laid; Works to be completed as per specifications and directions of PMC Engineer/ Owner. Rates are inclusive of fixing the supplied MCT block and providing necessary firesealing compound/silicon sealant compound for sealing purposes |
| 1383 | 11 kV (UE) armoured, XLPE, FRLS Power Cable of following size:- |
| 1384 | 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1385 | 1.1 KV Grade, Armoured, XLPE, FRLS Aluminium/ Copper Power Cable of following sizes: |
| 1386 | 1kV 1Cx400 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1387 | 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1388 | 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1389 | 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1390 | 1kV 4Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1391 | 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1392 | 1kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1393 | 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1394 | 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1395 | 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1396 | 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1397 | 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1398 | 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1399 | 1.1 KV Grade, Armoured, PVC, FRLS Copper Control Cable of following sizes |
| 1400 | 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1401 | 1kV 7Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1402 | 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1403 | 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1404 | 1.1 KV XLPE, FRLS Lighting Cable / Flexible cable/ Wires of following size |
| 1405 | 3Cx2.5 (CU) PVC FLEXIBLE cable(unarmoured) |
| 1406 | 1Cx2.5(CU) FRLS PVC WIRE |
| 1407 | 1.1kV, XLPE, FS armoured, Cable of following size:- |
| 1408 | 1kV 2Cx2.5 sq. mm Cu FS cable |
| 1409 | 1kV 3Cx6 sq. mm Cu FS cable |
| 1410 | 1kV 3Cx120 sq. mm Al FS cable |
| 1411 | Termination of Aluminium / Copper conductor PVC/XLPE insulated FRLS armoured cables (up to 1100 V grade) and connection of leads including fixing ofdouble compression cable glands, cutting and stripping of cable insulation, supplying & crimping the tinned copper lug on to the conductor, clamping of the cable-cores, marking with wire number, providing the cable tag as per specification, ferrules etc., including all labour and materials, as per approved drawings & specifications and directions of Engineer-in-Charge. Note : One (1) No. termination means both end termination of one cable |
| 1412 | 1kV 2Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed/FS Cable |
| 1413 | 1kV 2Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1414 | 1kV 3Cx2.5 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1415 | 1kV 3Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed/FS Cable |
| 1416 | 1kV 4Cx6 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1417 | 1kV 3Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1418 | 1kV 4Cx16 sq. mm Cu cable with XLPE insulated armoured FRLS PVC sheathed |
| 1419 | 1kV 3.5Cx35 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1420 | 1kV 3Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1421 | 1kV 3.5Cx50 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1422 | 1kV 3.5Cx70 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1423 | 1kV 3Cx120 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed/FS Cable |
| 1424 | 1kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1425 | 1kV 1Cx400 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1426 | 1kV 3Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1427 | 1kV 5Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1428 | 1kV 12Cx2.5 sq. mm Cu cable with PVC insulated armoured FRLS PVC sheathed |
| 1429 | Termination of HT Cable i.e. fixing of HT End Termination Kit |
| 1430 | Heat shrinkable end termination kit/jointing kit suitable for 11 kV (UE) XLPE, FRLS armoured cables of following sizes. |
| 1431 | Outdoor type heat shrinkable termination kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1432 | Indoor type heat shrinkable termination kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1433 | Jointing kit for 11/11 kV 3Cx240 sq. mm Al cable with XLPE insulated armoured FRLS PVC sheathed |
| 1434 | Laying of following sizes of G.I. Pipes (medium) complete with accessories (bends, reducers, couplers etc.) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of PMC Engineer/ Owner. |
| 1435 | GI Pipe for cable Protection Class-B Galvanized Iron (G.I. pipes) complete with accessories (bends, reducers, couplers etc.) of following sizes:- |
| 1436 | 150 mm NB |
| 1437 | 100 mm NB |
| 1438 | 75 mm NB |
| 1439 | 50 mm NB |
| 1440 | 25 mm NB |
| 1441 | Normal earth pit with GI perforated pipe (work includes all civil work like constrcution of the RCC chamber, CI cover, ) |
| 1442 | Earth pit for electronic earthing with copper plate |
| 1443 | Laying of Hot Dip Galvanized G.I./Cu earth strips (Galvanisation of 610 gm/ sqm of exposed area), PVC insulated Cu cable of following sizes for earthing and lightning protection. |
| 1444 | 50x6 mm GS flat as main earth grid conductor and earthing of major equipment |
| 1445 | 50x6 mm Cu flat as earthing conductor for coonection with pile reinforment bar which will act as earth grid termination with sea water |
| 1446 | 8 SWG Solid GI Wire |
| 1447 | 10MM GI wire rope |
| 1448 | 35x6 mm GI Flat for earthing & lightning protection conductor |
| 1449 | 25 sq.mm. Braided Cu Flexible Cable |
| 1450 | Hot dip galvanized GI earth bus bar of size 400 X 75X 6 thick with fixing materials as per Drg. |
| 1451 | 25 mm dia 1 m long GI rod for vertical air termination |
| 1452 | Flexible cable for static earth - 20 m long 10 sq. mm flexible Cu cable with lug at one end and crocodile clip at other end |
| 1453 | Test Linkboxfor lightning protection |
| 1454 | Installation of the following material for filling of uncovered portion of the trench etc. |
| 1455 | 6 mm thick chequred plate |
| 1456 | Installation, Testing & Commissiong of Motors of following rating: |
| 1457 | i) 0.37 kW to 3.7 kW. |
| 1458 | ii) 5.5 kW to 22 kW. |
| 1459 | iii) Above 22 kW to 50 kW. |
| 1460 | iii) Above 50 kW |
| 1461 | Installation, testing, commissioning of solar power generation system including intergration with existing grid/EDG power supply system |
| 1462 | 50mx20 m area at 5 acre plot, Minimum Power Generation 100 kW peak |
| 1463 | Charges towards the folllowing:a) Meter testing to be carried as per requirements of TANGEDCOc) Liasoning with TANGEDCO for incoming power supply - Co ordination with TANGEDCO for collecting TVM, charging of the electrical installation upon obtaining safety certificates, all incidentals connected to the services.d) Liasoning work for CEA/CEIG & PESO Clearance - Arranging for inspection of electrical installation by CEA/CEIG authorities & PESO including co-ordination and all incidental costs involved towards the same. Statutory fee shall be paid by IOCL.e) Preparation of electrical single line diagram including lamination with hard background and fixing the same at the sub station. |
| 1464 | SECTION 4 : FIREFIGHTING |
| 1465 | Remote Controlled Tower mounted water cum foam monitor (UL Listed) with Fire Proof Structure (25 m high)Flowrate: 2000 GPM |
| 1466 | Complete Foam System including Vertical Cylindrical, coned bottom type Foam Tanks (2 x 12 m3 capacity each), 2 Nos. electric motor driven rotary gear type Foam Pumps of 600 LPM Capacity & 15 bar head, inline balanced pressure proportioner (4 Nos.), one (1) No. Foam Filling Pump (25 m3/hr. capacity & 20 MLC head), one (1) No. flexible hose of 15 m length, piping, fittings, valves, instruments etc. |
| 1467 | Vertical Wet Pit type, Diesel Engine Driven Fire Water Pumps of Capacity 950 m3/hr & TDH 120 MLC including water cooled diesel engine, fuel piping, fuel tank, lube oil system, air intake system, industrial silencer, exhaust piping with insulation & aluminium cladding, caisson pipe, companion flanges, air release valve, PRV, controller with pressure sensing line with two check valves, etc.Design Standard: NFPA 20Casing Material: Duplex SSMain FW Pumps shall be Non-UL Listed/ Non-FM Approved |
| 1468 | Vertical Wet Pit type, Electric Motor driven Jockey Pumps of Capacity 190 m3/hr & TDH 125 MLC including drive motor, starter, caisson pipe, companion flanges, air release valve, controller with pressure sensing line with two check valves, etc.Design Standard: NFPA 20Casing Material: Duplex SSJockey Pumps shall Not be UL Listed. |
| 1469 | Fixing of Jumbo Curtain Nozzles on the unloading platform.Discharge Capacity: 6000 LPM @ 7 kg/cm2 gWorking Pressure Range: 7 - 11 kg/cm2 gHorz. Traverse / Vertical Traverse: 40/15 mAngle of Spray: 180 DegMOC: SS 316 |
| 1470 | Fixing of two numbers single outlet landing valve of size 63 mm diaas per IS:5290, Type-A of SS material including supply and Installation of stand post of size 100 NB with pipe, elbow, cross, RF pad Plate (for pipe to pipe connection) and necessary fittings & flanges including connecting / welding / installing the same in hydrant. |
| 1471 | Installation of FRP hose box of size 900 X 600 X 250 mm with structural support for mounting the box at minimum 1 M above the ground level including grouting the post complete. |
| 1472 | Water monitors with 38 mm dia Nozzle, 2580 LPM as per IS: 8442, 150 NB pipe, elbow, reducer, RF pad Plate (for pipe to pipe connection) and necessary fittings & flanges including Connecting/welding/installation of same in hydrant net work as per drawing. |
| 1473 | Fixing of 9 Kg DCP Fire Extinguisher |
| 1474 | Fixing of 4.5 Kg CO2 Fire Extinguisher |
| 1475 | Centralized Clean Agent (Novec 1230) based suppression system including Cylinders, cylinder racks, manifolds, Gas Release Panel, Nozzles, MRS, Abort Switch, pipes, fittings, valves etc. as per NFPA 2001 for the following Rooms: Jetty Control Building:a) Battery Room (Min. Risk Volume - 104 m3)b) Laboratory Room (Min. Risk Volume - 150 m3)c) UPS Room (Min. Risk Volume - 170 m3)d) Equipment Room (Min. Risk Volume - 240 m3)e) Control Room (Min. Risk Volume - 336 m3) |
| 1476 | Valves : |
| 1477 | Erection, Commisioning & testing of the following sizes of SS Manual Ball Valves (ASTM A182 F316L flanged # 800 ) as per Specification |
| 1478 | 15 mm dia |
| 1479 | 20 mm dia |
| 1480 | 25 mm dia |
| 1481 | 50 mm dia |
| 1482 | Erection, Commisioning & testing of the following sizes of SS Manual Ball Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 1483 | 100 mm dia |
| 1484 | 65 mm dia |
| 1485 | 80 mm dia |
| 1486 | Erection, Commisioning & testing of the following sizes of CS Glass Flake Lining Manual Butterfly Valves (ASTM A216 WCB flanged # 150) as per Specification |
| 1487 | 100 mm dia |
| 1488 | 150 mm dia |
| 1489 | 250 mm dia |
| 1490 | 350 mm dia |
| 1491 | Erection, Commisioning & testing of the following sizes of CS Glass Flake Lining Motorized Butterfly Valves (ASTM A216 WCB flanged # 150) as per Specification |
| 1492 | 200 mm dia |
| 1493 | 400 mm dia |
| 1494 | Erection, Commisioning & testing of the following sizes of SSMotorized Globe Valves (ASTM A351 CF3M flanged # 150 ) as per Specification |
| 1495 | 100 mm dia |
| 1496 | Erection, Commisioning & testing of the following sizes of SS Pneumatic Ball Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 1497 | 80 mm dia |
| 1498 | Erection, Commisioning & testing of the following sizes of Duplex SS Manual Gate Valves (ASTM A182 F51 flanged # 800 ) as per Specification |
| 1499 | 50 mm dia |
| 1500 | Erection, Commisioning & testing of the following sizes of CS Check Valves Glass Flake Lining (ASTM A216 WCB flanged # 150 ) as per Specification |
| 1501 | 150 mm dia |
| 1502 | 350 mm dia |
| 1503 | Erection, Commisioning & testing of the following sizes of SS Check Valves (ASTM A351 GR CF3M flanged # 150 ) as per Specification |
| 1504 | 50 mm dia |
| 1505 | 80 mm dia |
| 1506 | Erection, Commisioning & testing of Pressure relief valves (ASTM A 182 F316L flanged # 150 ) as per Specification |
| 1507 | 50mm X 25mm dia SRV |
| 1508 | Seamless & Welded Pipes |
| 1509 | Erection, Commisioning & testing of Duplex SS Seamless Pipes to ASTM A790 S318032, Dim. ASME B36.10 |
| 1510 | 15 mm NB SCH S-40S Plain ends |
| 1511 | 25 mm NB SCH S-40S Plain ends |
| 1512 | 50 mm NB SCH S-40S Bevel ends |
| 1513 | 80 mm NB SCH S-10S Bevel ends |
| 1514 | Erection, Commisioning & testing of CS Seamless Pipes to ASTM A106 Gr.B Poly Glass Flake Lining, Dim. ASME B36.10 |
| 1515 | 100mm NB SCH S-STD Bevel ends |
| 1516 | 150mm NB SCH S-STD Bevel ends |
| 1517 | 200mm NB SCH S-STD Bevel ends |
| 1518 | 250mm NB SCH S-STD Bevel ends |
| 1519 | 350mm NB SCH S-STD Bevel ends |
| 1520 | 400mm NB SCH S-STD Bevel ends |
| 1521 | 600mm NB SCH S-STD Bevel ends |
| 1522 | Erection, Commisioning & testing of SS Seamless Pipes to ASTM A312 Gr.TP 316L, Dim. ASME B 36.19 |
| 1523 | 15mm NB SCH S-40S Plain Ends |
| 1524 | 20mm NB SCH S-40S Plain Ends |
| 1525 | 25mm NB SCH S-40S Plain Ends |
| 1526 | 50mm NB SCH S-40S Bevel Ends |
| 1527 | 80mm NB SCH S-10S Bevel Ends |
| 1528 | 100mm NB SCH S-10S Bevel Ends |
| 1529 | PIPEFITTINGS: Welding, Erection and Testing of the following sizes of Elbows/ Tees/ Reducer made of seamless pipes with ends as per enclosed specifications for the following sizesNote: The fittings shall be Socket Welded for Sizes Less than 2\" as per ASME B 16.11 and Bevel ends for 2\" andabove and dimensions as per ASME B 16.9 |
| 1530 | 90 Deg LR Elbow ASTM A182 F51 |
| 1531 | 15mm NB Class 3000 |
| 1532 | 25mm NB Class 3000 |
| 1533 | 90 Deg LR Elbow ASTM A815 WPS31803 |
| 1534 | 50mm NB SCH S-10S |
| 1535 | 80mm NB SCH S-10S |
| 1536 | 90 Deg LR Elbow ASTM A234 Gr.WPB Poly Glass Lined |
| 1537 | 100mm NB SCH S-STD |
| 1538 | 150mm NB SCH S-STD |
| 1539 | 200mm NB SCH S-STD |
| 1540 | 250mm NB SCH S-STD |
| 1541 | 350mm NB SCH S-STD |
| 1542 | 400mm NB SCH S-STD |
| 1543 | 600mm NB SCH S-STD |
| 1544 | 90 Deg LR Elbow (1.5D) ASTM A403 Gr.WP316L |
| 1545 | 15mm NBClass 3000 |
| 1546 | 50mm NB SCH S-40S |
| 1547 | 80mm NB SCH S-10S |
| 1548 | 100mm NB SCH S-10S |
| 1549 | 45 Deg LR Elbow (1.5D) ASTM A182F51 |
| 1550 | 25mm NB Class 3000 |
| 1551 | 45 Deg LR Elbow (1.5D) ASTM A234 Gr.WPB Poly Glass Lined |
| 1552 | 200mm NB SCH S-STD |
| 1553 | 600mm NB SCH S-STD |
| 1554 | 45 Deg LR Elbow (1.5D) ASTM A403 Gr.WP316L |
| 1555 | 50mm NB SCH S-40S |
| 1556 | 80mm NB SCH S-10S |
| 1557 | Equal Tee ASTM A815WPS31803 |
| 1558 | 50mm NB SCH S-10S |
| 1559 | 80mm NB SCH S-10S |
| 1560 | Equal Tee ASTM A234 Gr.WPB Poly Glass Lined |
| 1561 | 100mm NB SCH S-STD |
| 1562 | 150mm NB SCH S-STD |
| 1563 | 250mm NB SCH S-STD |
| 1564 | Equal Tee ASTM A403 Gr.WP316L |
| 1565 | 50mm NB SCH S-40S |
| 1566 | 80mm NB SCH S-10S |
| 1567 | 100mm NB SCH S-10S |
| 1568 | Reducing Tee ASTM A234 Gr.WPB Poly Glass Lined |
| 1569 | 100 X 50 mm NBS-STD x S-STD |
| 1570 | 100 X 80 mm NBS-STD x S-STD |
| 1571 | 150 X 100 mm NBS-STD x S-STD |
| 1572 | 350 X 200 mm NBS-STD x S-STD |
| 1573 | 350 X 250 mm NBS-STD x S-STD |
| 1574 | 400 X 200 mm NBS-STD x S-STD |
| 1575 | 600 X 350 mm NBS-STD x S-STD |
| 1576 | 600 X 400 mm NBS-STD x S-STD |
| 1577 | Reducing TeeASTM A403 Gr.WP 316L |
| 1578 | 50 X 20 mm NBS-40S x S-40S |
| 1579 | 80 X 5 mm NBS-10S x S-40S |
| 1580 | Concentric Reducer ASTM A182 F51 |
| 1581 | 25 X 15 mm NB Class 3000 |
| 1582 | Concentric Reducer ASTM A815 WPS31803 |
| 1583 | 50 X 25 mm NB S-40S x S-40S |
| 1584 | Concentric Reducer ASTM A234 Gr.WPB Poly Glass Lined |
| 1585 | 100 X 50 mm NBS-STD x S-STD |
| 1586 | 150 X 100 mm NBS-STD x S-STD |
| 1587 | 350 X 200 mm NBS-STD x S-STD |
| 1588 | 350 X 250 mm NBS-STD x S-STD |
| 1589 | Concentric Reducer ASTM A182 Gr.F316L |
| 1590 | 50 X 25 mm NB S-40S x S-40S |
| 1591 | Concentric Reducer ASTM A403 Gr.WP316L |
| 1592 | 80 X 50 mm NB S-10S x S-40S |
| 1593 | 100 X 50 mm NB S-10S x S-40S |
| 1594 | Coupling ASTM A182F51 |
| 1595 | 25mm NB Class 3000 SWE |
| 1596 | Union ASTM A182F51 |
| 1597 | 25mm NB Class 3000 FTE |
| 1598 | Cap ASTM A815 WPS 31803 |
| 1599 | 50 mm NB SCH S-40S Bevel ends |
| 1600 | PIPEFITTINGS: Supplying the following sizes of Olets made of as per MSS SP 97 specifications for the following sizes |
| 1601 | SOCKOLET ASTM A182 Gr. F316L |
| 1602 | 50 X 15 Class 3000 |
| 1603 | 50 X 20 Class 3000 |
| 1604 | 80 X 15 Class 300 |
| 1605 | 80 X 20 Class 3000 |
| 1606 | 80 X 50 Class 3000 |
| 1607 | 100 X 15 Class 3000 |
| 1608 | 100 X 20 Class 3000 |
| 1609 | Weldolet ASTM A105 Poly Glass Lining |
| 1610 | 150 X 50 SCH S-STD |
| 1611 | 200 X 50 SCH S-STD |
| 1612 | 350 X 50 SCH S-STD |
| 1613 | 350 X 100 SCH S-STD |
| 1614 | 400 X 150 SCH S-STD |
| 1615 | 600 X 50 SCH S-STD |
| 1616 | 600 X 100 SCH S-STD |
| 1617 | 600 X 150 SCH S-STD |
| 1618 | 600 X 200 SCH S-STD |
| 1619 | ThreadoletASTM A182 Gr.F51 |
| 1620 | 50 X 15 Class 3000 |
| 1621 | 80 X 25 Class 3000 |
| 1622 | Erection, Commisioning & testing of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 1623 | 15mm NB |
| 1624 | 25mm NB |
| 1625 | 50mm NB |
| 1626 | Erection, Commisioning & testing of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 1627 | 15mm NB |
| 1628 | 20mm NB |
| 1629 | Erection, Commisioning & testing of following Socket Weld type- SWRF 125 AARH as perASTM A182 Gr.F316L DIM. ASME B16.5 Class 300 |
| 1630 | 25mm NB |
| 1631 | 50mm NB |
| 1632 | Erection, Commisioning & testing of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 1633 | 80mm NB SCH S-10S |
| 1634 | Erection, Commisioning & testing of following Weld neck type- WNRF 125 AARH as per ASTM A105 DIM. ASME B16.5 Class 150 Poly Glass Lined |
| 1635 | 100mm NB SCH S-STD |
| 1636 | 150mm NB SCH S-STD |
| 1637 | 200mm NB SCH S-STD |
| 1638 | 250mm NB SCH S-STD |
| 1639 | 350mm NB SCH S-STD |
| 1640 | 400mm NB SCH S-STD |
| 1641 | 600mm NB SCH S-STD |
| 1642 | Erection, Commisioning & testing of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 1643 | 50mm NB SCH S-40S |
| 1644 | 100mm NB SCH S-10S |
| 1645 | Erection, Commisioning & testing of following Weld neck type- WNRF 125 AARH as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 300 |
| 1646 | 80mm NB SCH S-10S |
| 1647 | Erection, Commisioning & testing of following BLRF 125 AARH flanges as per ASTM A182 Gr.F316L DIM. ASME B16.5 Class 150 |
| 1648 | 100mm NB |
| 1649 | Erection, Commisioning & testing of following BLRF 125 AARH flanges as per ASTM A182 Gr.F51 DIM. ASME B16.5 Class 150 |
| 1650 | 50mm NB |
| 1651 | Erection, Commisioning & testing of following Orifice Flange WNRF 125 AARH flanges as per ASTM A182 F316L DIM. ASME B16.36 Class 300 |
| 1652 | 80mm NB |
| 1653 | Erection, Commisioning & testing of following GASKET, 4.5 mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 150 |
| 1654 | 15mm NB |
| 1655 | 20mm NB |
| 1656 | 25mm NB |
| 1657 | 50mm NB |
| 1658 | 80mm NB |
| 1659 | 100mm NB |
| 1660 | 150mm NB |
| 1661 | 200mm NB |
| 1662 | 250mm NB |
| 1663 | 350mm NB |
| 1664 | 400mm NB |
| 1665 | 600mm NB |
| 1666 | Erection, Commisioning & testing of following GASKET, 4.5mm Thck Spiral Wound 316 Outer & Inner Ring with Graphite Filler, ASME B16.20, CLASS 300 |
| 1667 | 25mm NB |
| 1668 | 50mm NB |
| 1669 | 80mm NB |
| 1670 | Erection, Commisioning & testing of following HEXAGONAL NUT, ASTM A194 Gr.2H, ASME B18.2.2, FTE, Hot Dip Galvanized |
| 1671 | 1\" DIA |
| 1672 | 1-1/4\" DIA |
| 1673 | 3/4\" DIA |
| 1674 | 5/8\" DIA |
| 1675 | 7/8\" DIA |
| 1676 | Erection, Commisioning & testing of following HEXAGONAL NUT, ASTM A194 Gr.3M, ASME B18.2.2, FTE |
| 1677 | 1/2\" DIA |
| 1678 | 5/8\" DIA |
| 1679 | Erection, Commisioning & testing of following STUD BOLT, ASTM A193 Gr.B7, ASME B18.2.1, MTE, Hot Dip Galvanized |
| 1680 | 1\" DIA150 MM LONG |
| 1681 | 1-1/4\" DIA 185 MM LONG |
| 1682 | 3/4\" DIA 110 MM LONG |
| 1683 | 3/4\" DIA 120 MM LONG |
| 1684 | 5/8\" DIA 100 MM LONG |
| 1685 | 7/8\" DIA 130 MM LONG |
| 1686 | Erection, Commisioning & testing of following STUD BOLT,ASTM A193 Gr.B8M CL.2, ASME B18.2.1, MTE |
| 1687 | 1/2\" DIA 65 MM LONG |
| 1688 | 1/2\" DIA 75 MM LONG |
| 1689 | 5/8\" DIA95 MM LONG |
| 1690 | 5/8\" DIA100 MM LONG |
| 1691 | Erection, Commisioning & testing of following STUD BOLT,ASTM A193 Gr.B3M, ASME B18.2.1, MTE |
| 1692 | 1/2\" DIA 65 MM LONG |
| 1693 | 1/2\" DIA 75 MM LONG |
| 1694 | 3/4\" DIA120 MM LONG |
| 1695 | 5/8\" DIA95 MM LONG |
| 1696 | 5/8\" DIA85 MM LONG |
| 1697 | 5/8\" DIA100 MM LONG |
| 1698 | DELUGE VALVE SYSTEM : |
| 1699 | Erection, Commisioning & testing of 150 NB Ni-Al Bronze deluge valve assembly including its pnuematic trim and DV shall be auto reset type. |
| 1700 | MVW Spray System : |
| 1701 | Medium Velocity Water Spray NozzleType: Open & Non-clogOrifice Size: 1/2\" (M)Body Material: Al-BronzeNozzle K-factor: LaterSpray Angle: LaterUL Listed |
| 1702 | QB DetectorType: PendantResponse: Standard ResponseBody Material: Forged BrassEnd Connection: 1/2\" (M)Temperature Rating: 79 Deg CUL Listed |
| 1703 | SECTION 5 : CONTROL AND INSTRUMENTATION |
| 1704 | Erection & Installation along with supply & Fabrication of mounting accessories, Poles etc and commissioning ofField Instruments |
| 1705 | Erection & Installation along with supply & fabrication of mounting accessories etc and commissioning ofcontrol valves |
| 1706 | Erection & Installation along with supply & fabrication of mounting accessoriesincluding erection material for Junction box |
| 1707 | Instrument cablesInstallation & Laying, testing & commissioning , loop testing with cable tray laying, supports, cable glandings, lugs,ferruling and termination, clamping, tagging including supply of cable gland, PVC hood structural support material etc |
| 1708 | Optical fiber cable & HDPE ductInstallation & Laying/blowing inside HDPE duct, excavation, restoration, testing & commissioning ,OTDR, installation of route marker, splicing, erection of splice chamber, termination, with cable tray laying, supports, cable glanding, lugs, ferruling and termination, clamping, tagging including supply of cable gland, PVC hood structural support material etc. |
| 1709 | Corrosion Monitoring systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material for CMS system |
| 1710 | Metering system for POL and LPG LineErection & Installation, along with supply and fabrication of mounting accessories including erection material for Metering system. |
| 1711 | Fire detection systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material for Fire detection system. |
| 1712 | Gas detection systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material for Gas detection system. |
| 1713 | SCADA systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material for SCADA system |
| 1714 | Telecom systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material for Telecom system |
| 1715 | CCTV systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material |
| 1716 | EPABX systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material |
| 1717 | PAGA systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material |
| 1718 | Ship to shore linkErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material |
| 1719 | Walky-Talky systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material |
| 1720 | Surge relief systemErection & Installation, configruation, commissioning, trial run, along with supply and fabrication of mounting accessories including erection material. |
| 1721 | Barrier Gate with Boom and Proximity Card including card readers etc complete as per specifications. |
| 1722 | SECTION 6 : HVAC |
| 1723 | Erection, testing and commissioning of wall mounted air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 1724 | Split AC units located at Cabin-1:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 1725 | Split AC units located at UPS room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 1726 | Split AC units located at Laboratory:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 1727 | Split AC units located at Office:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 1728 | Erection, testing and commissioning of ceiling mountedcassette type air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 1729 | Split AC units located at Custom room:Total cooling capacity: 3.0 TRDehumidified air quantity: 1650 CMH |
| 1730 | Split AC units located at Control room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1250 CMH |
| 1731 | Split AC units located at Equipment room:Total cooling capacity: 3.0 TRDehumidified air quantity: 1650 CMH |
| 1732 | Split AC units located at Office:Total cooling capacity: 2.0 TRDehumidified air quantity: 1250 CMH |
| 1733 | Erection, testing and commissioning of Supply fan filter unit located at Transformer & Switchgear room:The supply fan-filter unit shall consist of wall mounted tube axial flow fan, drive motor, Inlet Louver, pre-filter, supply cowl with protective wire netting inside the room, supports and supporting structures, nuts and bolts, vibration isolators.Fan capacity: 10000 CMHStatic pressure: 20 mmWG |
| 1734 | Erection, testing and commissioning of Back draft damper located at Transformer & Switchgear room:The wall mounted back draft damper shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1450 mm x 550 mm |
| 1735 | Erection, testing and commissioning of Transfer air grille located at Transformer & Switchgear room:The wall mounted transfer air grille shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1450 mm x 550 mm |
| 1736 | Erection, testing and commissioning of Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. |
| 1737 | Exhaust fan located at DG room:Fan capacity: 8000 CMHStatic pressure: 8 mmWG |
| 1738 | Exhaust fan located at Air compressor room:Fan capacity: 6500CMHStatic pressure: 8 mmWG |
| 1739 | Erection, testing and commissioning of Exhaust fan located at Battery room:Wall mounted Exhaust fan shall consist of bifurcated type axial flow fan, drive motor (flame proof type), protective wire netting inside the room, gravity louver at fan outlet, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. All parts of this system coming in contact with acid fumes shall be epoxy painted.Fan capacity: 1500 CMHStatic pressure: 10 mmWG |
| 1740 | Erection, testing and commissioning of wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G. |
| 1741 | Intake louver located at DG room:Size: 1750 mm x 550 mm |
| 1742 | Intake louver located at Air compressor room:Size: 850 mm x 550 mm |
| 1743 | Intake louver located at Battery room:Size: 750 mm x 450 mm |
| 1744 | Intake louver located at Laboratory:Size: 750 mm x 450 mm |
| 1745 | Erection, testing and commissioning of Wall mounted propeller fan shall consist of propeller fan, drive motor, gravity louver at fan outlet, supports, nuts and bolts, vibration isolators etc. |
| 1746 | Propeller type exhaust fan located at BCW toilet:Fan capacity: 450 CMHStatic pressure: 4 mmWG |
| 1747 | Propeller type exhaust fan located at BCW WC:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1748 | Propeller type exhaust fan located at Toilet:Fan capacity: 550 CMHStatic pressure: 4 mmWG |
| 1749 | Propeller type exhaust fan located at Laboratory:Fan capacity: 1000 CMHStatic pressure: 6 mmWG |
| 1750 | Erection, testing and commissioning of Duct mounted In-line centrifugal / axial flow exhaust fan located at Pantry:Duct mounted In-line centrifugal / axial flow exhaust fan shall consist of fan, drive motor, ducting with grille, supports, nuts and bolts, vibration isolators etc.Fan capacity: 200 CMHStatic pressure: 5 mmWG |
| 1751 | HVAC for Fire water pump house at Jetty area |
| 1752 | Erection, testing and commissioning of Exhaust fan located at Fire water pump house:Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc.Fan capacity: 10000 CMHStatic pressure: 8 mmWG |
| 1753 | Erection, testing and commissioning of Intake louver located at Fire water pump house:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 1800 mm x 600 mm |
| 1754 | HVAC for Electrical cum Control Building at 5 Acre Plot |
| 1755 | Erection, testing and commissioning of wall mounted air cooled Non duct-able split air conditioners complete with hermetically sealed rotary compressors (suitable for R-407C / R-410A /R-32 refrigerant) of inverter driven and air cooled condensers in the Outdoor unit with powder coated GI casing, built-in electrical items & supports and Indoor unit housing dry panel type HDPE filters (efficiency 90% down to 10 micron), cooling coils, evaporator fans with two speed drive motors, control console, all encased in powder coated GI casings with swivelling type supply air grilles and decorative RA grilles and interconnecting refrigerant piping (duly insulated) between outdoor and indoor units and insulated drain piping, microprocessor based cordless remote control panel and plug top with connecting cable for each split unit.As required including the structural steel framework, pedestal/ bracket to mount the indoor & outdoor units, supports & clamps for indoor & outdoor units, refrigerant piping/cables, stabilizer, hold down nuts & bolts. |
| 1756 | Split AC units located at Equipment room:Total cooling capacity: 2.0 TRDehumidified air quantity: 1050 CMH |
| 1757 | Split AC units located at Control room:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 1758 | Split AC units located at Work station area:Total cooling capacity: 1.5 TRDehumidified air quantity: 750 CMH |
| 1759 | Split AC units located at Waiting room:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 1760 | Split AC units located at Meeting room:Total cooling capacity: 1.0 TRDehumidified air quantity: 500 CMH |
| 1761 | Erection, testing and commissioning of supply fan-filter unit shall consist of wall mounted tube axial flow fan, drive motor, Inlet Louver, pre-filter, supply cowl with protective wire netting inside the room, supports and supporting structures, nuts and bolts, vibration isolators. |
| 1762 | Supply fan filter unit located at Transformer & PMCC room:Fan capacity: 5000 CMHStatic pressure: 20 mmWG |
| 1763 | Supply fan filter unit located at MV Switchgear room:Fan capacity: 5000 CMHStatic pressure: 20 mmWG |
| 1764 | Erection, testing and commissioning of wall mounted back draft damper shall be made galvanized steel of frame thickness 16G & Blade thickness 18G. |
| 1765 | Back draft damper located at Transformer & PMCC room:Size: 800 mm x 500 mm |
| 1766 | Back draft damper located at Transformer & PMCC room:Size: 650 mm x 300 mm |
| 1767 | Back draft damper located at MV Switchgear room:Size: 650 mm x 500 mm |
| 1768 | Erection, testing and commissioning of Exhaust fan located at Battery room:Wall mounted Exhaust fan shall consist of bifurcated type axial flow fan, drive motor (flame proof type), protective wire netting inside the room, gravity louver at fan outlet, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc. All parts of this system coming in contact with acid fumes shall be epoxy painted.Fan capacity: 2000 CMHStatic pressure: 10 mmWG |
| 1769 | Erection, testing and commissioning of Intake louver located at Battery room:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 750 mm x 450 mm |
| 1770 | Erection, testing and commissioning of Wall mounted propeller fan shall consist of propeller fan, drive motor, gravity louver at fan outlet, supports, nuts and bolts, vibration isolators etc. |
| 1771 | Propeller type exhaust fan located at Guard toilet:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1772 | Propeller type exhaust fan located at Store:Fan capacity: 150 CMHStatic pressure: 2.5 mmWG |
| 1773 | Propeller type exhaust fan located at Gents Toilet:Fan capacity: 400 CMHStatic pressure: 4 mmWG |
| 1774 | HVAC for Warehouse at 5 Acre Plot |
| 1775 | Erection, testing and commissioning of Exhaust fan located at Warehouse:Wall mounted exhaust fan shall consist of tube axial flow fan, drive motor, protective wire netting inside the room, rain protection cowl with bird screen, supports and supporting structures, nuts and bolts, vibration isolators, etc.Fan capacity: 2500 CMHStatic pressure: 8 mmWG |
| 1776 | Erection, testing and commissioning of Intake louver located at Warehouse:The wall mounted air intake louver shall be made galvanized steel of frame thickness 16G & Blade thickness 18G.Size: 750 mm x 450 mm |
| 1777 | HVAC for Box Culvert |
| 1778 | Erection, testing and commissioning of cabinet type supply fan-filter unit shall consist of direct driven / belt driven centrifugal flow fan, drive motor, Inlet Louver, pre-filter, VCD at fan outlet, supports and supporting structures, nuts and bolts, vibration isolators. The fan outlet shall be connected to ducting system.Fan capacity: 24000 CMHStatic pressure: 33 mmWG |
| 1779 | Erection, testing and commissioning of Roof Extractor shall consist of roof mounted axial flow exhaust fan, drive motor, rain protection hood with bird screen, supports & supporting structure, grouting frame, bolts, nuts, transition piece (if required), vibration isolators, water sealing arrangement at the base and inspection door. The fan inlet shall be connected to ducting system.The exhaust fan shall be spark proof construction & motor shall be flame proof type.Fan capacity: 24000 CMHStatic pressure: 22 mmWG |
| 1780 | HVAC for duct works |
| 1781 | Erection, testing and commissioning of Ducting: Ductingshall be made of G.I. sheet of at least grade 180 as per IS 277. Bidder shall estimate & quote the ducting quantity, hanger support etc. according to \"Air conditioning & Ventilation layout of Control Building (Dwg. No. P.011265-M-21006-502)\" and \"Ventilation layout of Box Culvert (Dwg. No. P.011265-M-21006-505)\". |
| 1782 | 18G |
| 1783 | 20G |
| 1784 | 22G |
| 1785 | 24G |
| 1786 | Erection, testing and commissioning of Supply air Grille: The supply air grille shall be made up of Aluminium construction and painted with two (2)coats of powder coating paints. Supply air grille shall be provided with volume control damper. The grille frame and louvers shall be manufactured of at least 20G and 22G respectively. |
| 1787 | Size: 800 x 300 |
| 1788 | Erection, testing and commissioning of Return air Grille: The return air grille shall be made up of Aluminium construction and painted with two (2)coats of powder coating paints. Return air grille shall be provided without volume control damper. The grille frame and louvers shall be manufactured of at least 20G and 22G respectively. |
| 1789 | Size: 600 x 300 |
| 1790 | Size: 300 x 300 |
| 1791 | Erection, testing and commissioning of Flexible connection: Flexible connectionshall be fire retardant type. Flexible connections of at least 150 mm length shall be provided at each connection between ductwork and fan units. Thequantity shall be estimated according to \"Air conditioning & Ventilation layout of Control Building (Dwg. No. P.011265-M-21006-502)\" and \"Ventilation layout of Box Culvert (Dwg. No. P.011265-M-21006-505)\". |
| 1792 | PART C - COMPOSITE WORKS |
| 1793 | SECTION 1: MARINE CIVIL WORKS |
| 1794 | PRELIMINARY SITE WORKS |
| 1795 | Positioning of sufficient quantity of structural steel material for piling gantries along with suitable piling rigs includingjackupplatform and other necessary accessories for installing vertical piles of dia 1200 to 1400mm bored cast - insitu piles. |
| 1796 | Positioning of sufficientnumberofBatching Plant, Floating Transit Mixers, Concrete Pumps and Concrete Accessories etc. for concrete works in sea and land. |
| 1797 | Positioning of sufficientnumberof Cranes (suitable capacity), equipment and accessories for precasting yard. |
| 1798 | Positioning ofsufficient number of Marine transport Barges and tugs for carrying materials and precast elements. |
| 1799 | Positioning of sufficient number of equipment for erection of precast element including Barge mounted cranes etc. and establishing site office for Client. |
| 1800 | DEMOBILIZATION |
| 1801 | Demobilisationfrom site of all piling plant & equipment aftercompletionbroughtunderitem1.1 (a) above. |
| 1802 | Demobilisation from site of all Batching Plant, Floating TransitMixers,ConcretePumpsand ConcreteAccessoriesetc.aftercompletionbrought under item No.1.1 (b) above. |
| 1803 | Demobilisationfrom site of all Cranes (suitable capacity), equipment and accessories for precasting yard after completion brought under item 1.1 (c) above. |
| 1804 | Demobilisation from site of all Marine transport Barges and tugs after completion brought under item 1.1 (d) above. |
| 1805 | Demobilisation from site of all Barge mounted cranes etc. after completionbrought under item 1.1 (e) above. |
| 1806 | PRELIMINARIES |
| 1807 | Carrying out Geodetic survey for as-built location of piles and deck slab of :a) MLT-1 approach trestle b) MLT-1 approach bridge connecting the jetty and N. Breakwater c) LNG jetty approach trestle d) MD-6 of LNG jettyto identify the location with coordinates of each of the existing piles of the above structures, including all equipment like survey boat, dGPS, total station including incorporating the details of the survey in the autocad version of the Layout/Bathymetry drawings, etc complete . |
| 1808 | Carrying out geotechnical investigation for confirmatory boreholes by drilling in to existing seabed consisting of all types of soil at the specified locations as shown in the borehole location drawing. The boreholes should be drilled upto a sound stratum or hard soil (minimum and maximum drill depth shall be 25m and 50m respectively) as per the specifications enclosed in the tender using jackup rigs, soil boring machines, sampling tools, taking undisturbed samples at every 1.5m, carrying out SPT at every 1.5m and conducting laboratory tests on collected soil samples to determine their engineering properties such as moisture content, Atterberg limits, density, shear strength, unconfined compressive strength, particle size distribution, chemical properties, electrical resistivity, chloride and sulphate content in soil and water and preparing report for engineering and physical properties etc all complete in accordance with IS 1892, IS 4651 and other relevant codes and standards under the supervision of PMC Engineer/ Site Engineer. |
| 1809 | Carrying out bathymetric survey at the specified location covering an area as shown in the drawings, including required equipment like dGPS, multi beam echo sounder, motion sensor, sound velocity profiler, navigation equipment, data logging and processing equipment, etc complete as per specifications. |
| 1810 | MARINE CIVIL WORKS - SUBSTRUCTURE AND MARINE DECK |
| 1811 | PART 1: PILING |
| 1812 | Shifting and setting up of piling plant and equipment using gantry and platform or jackup rig, tripods, winch / rile driving rig, rotary drilling rig, bailers, chisellers etc (as per the methodology of work) at each pile location for breasting and mooring dolphins for providing of 1200mm and 1400 mm vertical MS steel liner for boring work and for concreting the piles including fabrication and erection of pile driving plant, staging with various steel plates, girders, angles, channels etc., including cost of steel items, welding charges, strutting and fixing in position at each location, cost of mobilization and demobilization of all equipment, transportation charges of all materials to worksite, all labour charges andtools etc. complete. |
| 1813 | For 1200mm dia piles: |
| 1814 | Unloading Platform |
| 1815 | Approach Bridge |
| 1816 | Access Trestle |
| 1817 | Jetty Control Building |
| 1818 | Fire Water Pump House |
| 1819 | Approach Trestle - Zone 2 |
| 1820 | Approach Trestle - Zone 3 |
| 1821 | Approach Trestle - Zone 4 |
| 1822 | Walkways |
| 1823 | For 1400mm dia piles: |
| 1824 | Breasting Dolphins |
| 1825 | Mooring Dolphins |
| 1826 | Providing, Fabricating and delivering of 8mm thick MS liner with 8 mm thick stiffeners at bottom of liners, as per drawing, for 1400mm / 1200mm dia vertical cast-in-situ RCC pile for each pile in unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle including cost of supply ofsteel plates confirming to IS: 2062, Grade E250, cost of all other materials, transportation charges of structural steel plate to Work Site, all labour charges, hire charges,tools, rolling, cutting, welding etc., complete. |
| 1827 | Unloading Platform |
| 1828 | Approach Bridge |
| 1829 | Access Trestle |
| 1830 | Jetty Control Building |
| 1831 | Fire Water Pump House |
| 1832 | Approach Trestle - Zone 2 |
| 1833 | Approach Trestle - Zone 3 |
| 1834 | Approach Trestle - Zone 4 |
| 1835 | Walkways |
| 1836 | Breasting Dolphins |
| 1837 | Mooring Dolphins |
| 1838 | Boring / drilling through all types of soil and including soil removal for vertical piles for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, marine deck for jetty control building and pumphouse building, approach trestle (Zone 2 to Zone 4) from the existing sea bed level to founding level (firm stratum) including cost of winch / Pile driving rig, rotary drilling machine, RCD machine.Note:1) The sample of bored materials at regular interval shall be collected and produced for verification at No extra cost and in case of any dispute the samples so collected shall be referred to an authorised / registered laboratory approved/selected by Owner and the decision of such authorised laboratory is final and binding on both the parties, however the cost of testing shall be borne by the contractor. Pile terminal shall be decided in consultation with the PMC Engineer. |
| 1839 | 1200 mm Dia |
| 1840 | Unloading Platform |
| 1841 | Approach Bridge |
| 1842 | Access Trestle |
| 1843 | Jetty Control Building |
| 1844 | Fire Water Pump House |
| 1845 | Approach Trestle - Zone 2 |
| 1846 | Approach Trestle - Zone 3 |
| 1847 | Approach Trestle - Zone 4 |
| 1848 | Walkways |
| 1849 | 1400 mm Dia |
| 1850 | Breasting Dolphins |
| 1851 | Mooring Dolphins |
| 1852 | Providing and laying design mix concrete of RCC M40 grade in accordance with IS 456 (Latest Edition) using coarse aggregate, sand and 53 grade Ordinary Portland cement confirming to IS 455 for RCC piles in unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle by using tremie with hopper arrangements, excluding cost of fabrication, fixing of reinforcement, which will be paid separatelybut including cost of cement, stone chips, sand, cost of all labour charges, centering and shuttering,mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost of tools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India/ IITs/ NITs/ NABL Accredited Labs ).Note : Payment shall only be made for the concrete work from pile founding level to the pile cut-off level including 600mm above the cut-off level. Any concrete above the 600mm shall Not paid. |
| 1853 | Unloading Platform |
| 1854 | Approach Bridge |
| 1855 | Access Trestle |
| 1856 | Jetty Control Building |
| 1857 | Fire Water Pump House |
| 1858 | Approach Trestle - Zone 2 |
| 1859 | Approach Trestle - Zone 3 |
| 1860 | Approach Trestle - Zone 4 |
| 1861 | Walkways |
| 1862 | Breasting Dolphins |
| 1863 | Mooring Dolphins |
| 1864 | Supply, deliver and transportation of reinforcement steel with a minimum yield strength of 500 N/mm2 and minimum elongation of 16% or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement cages as per drawing for cast-in-situ piles for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle, including cost of fabrication, fixing dowels, shear ties, cutting, bending, tying, lapping and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour charges, transportation charges of all materials to Work Site, cost of binding wires, all other items required for the work andtools etc. complete. |
| 1865 | Unloading Platform |
| 1866 | Approach Bridge |
| 1867 | Access Trestle |
| 1868 | Jetty Control Building |
| 1869 | Fire Water Pump House |
| 1870 | Approach Trestle - Zone 2 |
| 1871 | Approach Trestle - Zone 3 |
| 1872 | Approach Trestle - Zone 4 |
| 1873 | Walkways |
| 1874 | Breasting Dolphins |
| 1875 | Mooring Dolphins |
| 1876 | Dressing / chipping of the RCC pile head of 1400mm / 1200 mm dia including cutting of steel liners & trimming of extra concreted pile above the designed cut off level and exposing the reinforcement to receive fresh concrete for beams, bracing, pile muffs etc., bending the reinforcement for new works, cost of all equipment, all labour charges,tools etc. complete. |
| 1877 | Unloading Platform |
| 1878 | Approach Bridge |
| 1879 | Access Trestle |
| 1880 | Jetty Control Building |
| 1881 | Fire Water Pump House |
| 1882 | Approach Trestle - Zone 2 |
| 1883 | Approach Trestle - Zone 3 |
| 1884 | Approach Trestle - Zone 4 |
| 1885 | Walkways |
| 1886 | Breasting Dolphins |
| 1887 | Mooring Dolphins |
| 1888 | Supply, transport to site, deliver, install testing arrangements, equipments and spares, barges, working platforms and access ways as necessary with provision of specialist personal, to carry out Non-destructive (low strain) dynamic integrity testing of bored cast in – situ RCC working piles (dia 1200 to 1400 mm) selected by PMC Engineer/ Site Engineer including necessary test reports, interpretations with all other test reports etc. as per specification complete. |
| 1889 | Unloading Platform |
| 1890 | Approach Bridge |
| 1891 | Access Trestle |
| 1892 | Jetty Control Building |
| 1893 | Fire Water Pump House |
| 1894 | Approach Trestle - Zone 2 |
| 1895 | Approach Trestle - Zone 3 |
| 1896 | Approach Trestle - Zone 4 |
| 1897 | Walkways |
| 1898 | Breasting Dolphins |
| 1899 | Mooring Dolphins |
| 1900 | Supply, transport to site, deliver, construct test and anchor piles/system, install testing arrangements equipment and spares, barges, reaction anchors, structural frame systems with working platforms and access ways as necessary with provision of specialist personal, to carry out initial and routine static vertical pile load test on test pile (bored cast in-situ pile) selected by PMC Engineer/ Owner including construction of test pile, anchor pile, anchorage system, kent ledge frame, testing equipment, labour, etc with interpretation of test results complete. The cost of all materials such as RCC (cement, sand, aggregate, water), reinforcement, structural steel, nuts and bolts, prestressing wires, testing equipment, etc all complete shall be paid under this item. Test load for initial pile load test shall be 2.5 times the working load on piles (2.5 x 500MT (min) = 1250 MT min). Test load for routine pile load test shall be 1.5 times the working load on piles (1.5 x 500MT (min) = 750 MT min).Test pile and anchor piles or anchorage system if any shall be completely cut and removed above seabed after the completion of test.Note : Test pile shall be carried out prior to any working pile construction and the location of test pile shall Not obstruct the working pile. |
| 1901 | Routine Static Vertical Pile Load Test |
| 1902 | Unloading Platform |
| 1903 | Approach Trestle - Zone 2 |
| 1904 | Approach Trestle - Zone 3 |
| 1905 | Initial Static Vertical Pile Load Test |
| 1906 | Approach Trestle - Zone 4 |
| 1907 | Carrying out high strain Routine Dynamic load test on vertical pile in unloading platform, approach trestle, breasting and mooring dolphins and pump house with test load and testing procedure as per ASTM 4945 latest, including cost of all materials for making platform with steel members, weight materials, all labour charges, workmanship instrumentation, electronic devices, mechanical handling equipment, all other materials required for successful completion of load test, including removal of added portion of pile for testing after completion of test.Note : Dynamic load test shall be carried out on working piles and the pile head shall be extended by at least 2m above the pile cut-off level. The test piles shall be selected by the PMC Engineer/Owner for each structure based his judgement and it is to be treated as final. |
| 1908 | Unloading Platform |
| 1909 | Approach Bridge |
| 1910 | Access Trestle |
| 1911 | Jetty Control Building |
| 1912 | Fire Water Pump House |
| 1913 | Approach Trestle - Zone 2 |
| 1914 | Approach Trestle - Zone 3 |
| 1915 | Approach Trestle - Zone 4 |
| 1916 | Breasting Dolphins |
| 1917 | Mooring Dolphins |
| 1918 | Supply, transport to site, deliver, construct test and anchor piles/system, install testing arrangements equipment and spares, barges, reaction anchors, structural frame systems with working platforms and access ways as necessary with provision of specialist personal, to carry out initial pull-out pile load test on test pile (bored cast in-situ pile) selected by PMC Engineer/ Site Engineer including construction of test pile, anchor pile, anchorage system, kent ledge frame, testing equipment, labour, etc with interpretation of test results complete. The cost of all materials such as RCC (cement, sand, aggregate, water), reinforcement, structural steel, nuts and bolts, prestressing wires, testing equipment, etc all complete shall be paid under this item. Load test shall be conducted on test piles with a maximum load of 150 MT. Test pile and anchor piles or anchorage system if any shall be completely cut and removed above seabed after the completion of test.Note : Test pile shall be carried out prior to any working pile construction and the location of test pile shall Not obstruct the working pile. |
| 1919 | Supply, transport to site, deliver, construct test and anchor piles/system, install testing arrangements equipment and spares, barges, reaction anchors, structural frame systems with working platforms and access ways as necessary with provision of specialist personal, to carry out initial horizontal pile load test on test pile (bored cast in-situ pile) selected by PMC Engineer/ Site Engineer including construction of test pile, anchor pile, anchorage system, kent ledge frame, testing equipment, labour, etc with interpretation of test results complete. The cost of all materials such as RCC (cement, sand, aggregate, water), reinforcement, structural steel, nuts and bolts, prestressing wires, testing equipment, etc all complete shall be paid under this item. Load test shall be conducted on test piles with a maximum load of 2 times the working load on piles (2 x 10MT=20MT). Test pile and anchor piles or anchorage system if any shall be completely cut and removed above seabed after the completion of test.Note : Test pile shall be carried out prior to any working pile construction and the location of test pile shall Not obstruct the working pile. |
| 1920 | PART 2: PILE MUFFS, DECK SLAB AND BEAMS |
| 1921 | Providing cast – in situ reinforced cement concrete of design mix grade M40 in accordance with IS 456 (Latest Edition) using coarse aggregate, sand and 53 grade Ordinary Portland cement confirming to IS 455, as per design mix in cast-in-situ for portion of beams, slabs, Column etc for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle as indicated in the drawing, excluding cost of fabrication, fixing of reinforcement, but including cost of cement, stone chips, sand,centering and shuttering cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost of tools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India IITs/ NITs/ NABL Accredited labs. |
| 1922 | Unloading Platform |
| 1923 | Approach Bridge |
| 1924 | Access Trestle |
| 1925 | Jetty Control Building |
| 1926 | Fire Water Pump House |
| 1927 | Approach Trestle - Zone 2 |
| 1928 | Approach Trestle - Zone 3 |
| 1929 | Approach Trestle - Zone 4 |
| 1930 | Walkways |
| 1931 | Breasting Dolphins |
| 1932 | Mooring Dolphins |
| 1933 | Providing pre-cast reinforced cement concrete of design mix grade M40 in accordance with IS 456 (Latest Edition) using coarse aggregate , sand and 53 grade Ordinary Portland cement confirming to IS 455, as per design mix in cast-in-situ beams, slabs, Column etc for unloading platform, breasting and mooring dolphins, pump house and approach trestle as indicated in the drawing, excluding cost of fabrication, fixing of reinforcement, but including cost of cement, stone chips, sand, cost of centering and shuttering, cost of all labour charges, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost of tools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India/ IITs/ NITs/ NABL Accredited labs). |
| 1934 | Unloading Platform |
| 1935 | Approach Bridge |
| 1936 | Access Trestle |
| 1937 | Jetty Control Building |
| 1938 | Fire Water Pump House |
| 1939 | Approach Trestle - Zone 2 |
| 1940 | Approach Trestle - Zone 3 |
| 1941 | Approach Trestle - Zone 4 |
| 1942 | Walkways |
| 1943 | Breasting Dolphins |
| 1944 | Mooring Dolphins |
| 1945 | Providing and laying design mix concrete of RCC M30 grade in accordance with IS 456 (Latest Edition) using coarse aggregate, sand and 53 grade Ordinary Portland cement confirming to IS 455, as per design mix for screed (wearing coat) in approach trestle as indicated in the drawing, excluding cost of fabrication, fixing of reinforcement,but including cost of cement, stone chips, sand, cost of all labour charges, mixing, conveying, placing, centering and shuttering, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost oftools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India / IITs/ NITs/ NABL Accredited labs). |
| 1946 | Unloading Platform |
| 1947 | Approach Bridge |
| 1948 | Access Trestle |
| 1949 | Approach Trestle - Zone 2 |
| 1950 | Approach Trestle - Zone 3 |
| 1951 | Approach Trestle - Zone 4 |
| 1952 | Supply, deliver and transportation of reinforcement steel with a minimum yield strength of 500 N/mm2 and minimum elongation of 16% or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement in superstructure works including pile muff, beams, slabs, Column etc for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle, including cost of fabrication & fixing, cost of corrosion resistant deformed bars, all handling charges, cutting, bending, lapping, tying and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour charges, cost of binding wire, transportation charges for all materials to worksite, all other items required for the work and tools etc. complete. |
| 1953 | Unloading Platform |
| 1954 | Approach Bridge |
| 1955 | Access Trestle |
| 1956 | Jetty Control Building |
| 1957 | Fire Water Pump House |
| 1958 | Approach Trestle - Zone 2 |
| 1959 | Approach Trestle - Zone 3 |
| 1960 | Approach Trestle - Zone 4 |
| 1961 | Walkways |
| 1962 | Breasting Dolphins |
| 1963 | Mooring Dolphins |
| 1964 | PART 3: BERTH FITTINGS |
| 1965 | Supplying, Testing and fixing of quick releasing mooring hooks (QRMH) of capacity as per specifications and at the required locations as per the approved drawings, including cost of mooring hook, cost of all labour charges, transportation charges andtools etc., complete. |
| 1966 | Breasting Dolphins |
| 1967 | Mooring Dolphins |
| 1968 | Supplying, Testing and fixing of bollards of capacity as per specifications and at the required locations as per the approved drawings, including cost of mooring hook, cost of all labour charges, transportation charges andtools etc., complete. |
| 1969 | Fire Water Pump House |
| 1970 | Supplying, Testing and fixing of cone fenders of having Energy absorption capacity of 2350 kN-m with Not to exceed reaction of 2175 kN including all required accessories etc a, including cost of fender with all its accessories, all labour charges, transportation charges up to site andtools etc., complete. |
| 1971 | Breasting Dolphins |
| 1972 | Supplying, Testing and fixing of arch fenders of having Energy absorption capacity of 26 kN-m with Not to exceed reaction of 200 kN including all required accessories etc a, including cost of fender with all its accessories, all labour charges, transportation charges up to site and tools etc., complete. |
| 1973 | Fire Water Pump House |
| 1974 | Supply, fabricate and fix in position according to the drawings and specifications rubberised steel ladders from approved manufacturer using anchor bolts and resin sleeves and as directed at site of work, including all labour, materials, tools, equipments, fuel, transport, curing etc., all complete |
| 1975 | Breasting Dolphins |
| 1976 | Mooring Dolphins |
| 1977 | Supply, fabricate, transport, handle and erect in position stainless steel handrails using pipes and toe plates using stainless steel conforming to SS316L including profile cutting, assembling, hoisting, fixing in position, welding, inspection and applying a priming coat of approved steel primer and top coat of minimum thickness as specified in the specifications made of approved paint all as per specifications and drawings including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. The cost shall include all fabrication, transportation of the steel structure assembly in part or as a whole, lifting using floating crafts and cranes, erection and fixing on the concrete structure with appropriate supporting arrangement, base plates and anchor bolts etc complete. |
| 1978 | Unloading Platform |
| 1979 | Approach Bridge |
| 1980 | Access Trestle |
| 1981 | Jetty Control Building |
| 1982 | Fire Water Pump House |
| 1983 | Approach Trestle - Zone 2 |
| 1984 | Approach Trestle - Zone 3 |
| 1985 | Approach Trestle - Zone 4 |
| 1986 | Walkways |
| 1987 | Breasting Dolphins |
| 1988 | Mooring Dolphins |
| 1989 | Supplying, Testing and fixing of Docking AId System (DAS) as per specifications and at the required locations as per the approved drawings, including cost of all equipment, cost of all labour charges, transportation charges andtools etc., complete. |
| 1990 | Breasting Dolphins |
| 1991 | Supplying, Testing and fixing of Mooring Load Monitoring System (MLMS) as per specifications and at the required locations as per the approved drawings, including cost of all equipment, cost of all labour charges, transportation charges andtools etc., complete. |
| 1992 | Mooring Dolphins |
| 1993 | PART 4: MISCELLANEOUS ITEMS |
| 1994 | Supply, fabricate, transport, handle and erect in position catwalk / walkway structure made of structural steel hollow members of any dimension with a minimum yield strength of 310 N/mm2 and/or shapes, plates, anchor bolts and built up sections conforming to IS 2062 E350 including profile cutting, assembling, hoisting, fixing in position, welding, inspection and hot dip galvanizing as specified in the specifications made of approved paint all as per specifications and drawings including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. The cost shall include all fabrication, transportation of the catwalk assembly, lifting using floating crafts and cranes, erection and fixing on the concrete structure with appropriate sliding and pin arrangement etc complete. |
| 1995 | Walkways |
| 1996 | Providing and fixing in position Steel angle ISA 50x50x6 with anchors in to edge concrete and providing and fixing 12 mm thick bitumen impregnated fibre board confirming to IS 1838 including cost of sealing compound in expansion joints as per the direction of PMC Engineer/ Owner etc., including the cost of 12 mm thick bitumen impregnated fibre board, all labour charges,tools, transportation charges of all materials to work site etc. complete. |
| 1997 | Unloading Platform |
| 1998 | Approach Trestle - Zone 2 |
| 1999 | Approach Trestle - Zone 3 |
| 2000 | Approach Trestle - Zone 4 |
| 2001 | Supply, fabricate, transport, handle and install in position Hot dip Galvanised Anchor bolts of minimum diameter and length as specified in the drawings and as per specifications including cost of all materials, fitting charges, all labour charges, transportation charges andtools etc. complete. The cost shall include all fabrication, cutting and drilling holes in the base plates, erection and fixing on the new concrete structure. Note: The anchor bolts, Washers and nuts shall conform to IS 1363 Grade 8.8. |
| 2002 | Unloading Platform |
| 2003 | Walkways |
| 2004 | Breasting Dolphins |
| 2005 | Mooring Dolphins |
| 2006 | Providing and laying approved brand of epoxy grout of minimum compressive strength 100 MPa for a minimum thickness of 30mm (or shown in the drawing) below the base plates for all structures including shuttering on sides, cost of all labour charges, mixing, conveying, placing, consolidation, consumables and all other equipment, cost of tools etc. complete. |
| 2007 | Unloading Platform |
| 2008 | Walkways |
| 2009 | Breasting Dolphins |
| 2010 | Mooring Dolphins |
| 2011 | Supply, fabricate, transport, handle and erect in position Galvanisedwith minimum 85 micron total coated thickness Electro forged Grating purchased from approved manufacturer and thickness as shown in construction drawings and all as per specifications including clips, supports using steel conforming to IS 2062 Grade E250 A/B including cutting, hoisting, fixing in position and including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. |
| 2012 | Unloading Platform |
| 2013 | Approach Bridge |
| 2014 | Access Trestle |
| 2015 | Fire Water Pump House |
| 2016 | Walkways |
| 2017 | Supply, fabricate, transport, handle and weld on to the bottom and top base plates of walkway support with Flourogold bearing plate of thickness 2.4 mm as per drawings and specifications including cutting, hoisting, fixing in position and including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. |
| 2018 | Walkways |
| 2019 | Supply, fabricate, transport, handle and install UPVC drain pipes of diameter 100 mm as per drawings and specifications including cutting, hoisting, fixing in position and including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. |
| 2020 | Unloading Platform |
| 2021 | Approach Bridge |
| 2022 | Access Trestle |
| 2023 | Jetty Control Building |
| 2024 | Fire Water Pump House |
| 2025 | Approach Trestle - Zone 2 |
| 2026 | Approach Trestle - Zone 3 |
| 2027 | Approach Trestle - Zone 4 |
| 2028 | Breasting Dolphins |
| 2029 | Mooring Dolphins |
| 2030 | Supply, fabricate, transport and install edge Nosing (protection) of circular pipe of minimum thickness 16mm with full butt weld including F12mm dia (450mm long) MS lugs @150mm c/c as per drawings and specifications including cutting, fixing in position and including cost of all materials, fitting charges, all labour charges, transportation charges and tools etc. complete. |
| 2031 | Breasting Dolphins |
| 2032 | Mooring Dolphins |
| 2033 | Providing and laying rockfill revetment as primary armour using stones of size of 500kg to 1000kg in layer Not exceeding 1400mm thick to the required slope, line and level including packing filling the gaps with smaller boulders as per specifications & drawings, etc. including cost of all materials, all labour charges, transportation charges and tools etc. complete. as directed by the PMC Engineer. |
| 2034 | Approach Bridge |
| 2035 | Providing and laying Non-woven geotextile layer as filter layer under the footing as indicated in the drawings and specifications to the required line and level including packing filling the gaps etc. including cost of all materials, all labour charges, transportation charges and tools etc. complete. as directed by the PMC Engineer. |
| 2036 | Approach Bridge |
| 2037 | MARINE CIVIL WORKS - SUPERSTRUCTURE |
| 2038 | Providing cast – in situ reinforced cement concrete of design mix grade M35 in accordance with IS 456 (Latest Edition) using coarse aggregate, sand and 53 grade Ordinary Portland cement confirming to IS 455, as per design mix in cast-in-situ for portion of beams, slabs, Column etc for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle as indicated in the drawing, excluding cost of fabrication, fixing of reinforcement,but including cost of cement, stone chips, sand, cost of all labour charges, centering and shuttering, mixing, conveying, placing, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost of tools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India/ IITs/ NITs/ NABL Accredited labs). |
| 2039 | Unloading Platform |
| 2040 | Control Building |
| 2041 | Fire Water Pump House |
| 2042 | Marine Approach Trestle |
| 2043 | Supply, deliver and transportation of reinforcement steel with a minimum yield strength of 500 N/mm2 and minimum elongation of 16% or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement in superstructure works including pile muff, beams, slabs, Column etc for unloading platform, breasting and mooring dolphins, access trestle, approach bridge, pump house, jetty control building and approach trestle, including cost of fabrication & fixing, cost of corrosion resistant deformed bars, all handling charges, cutting, bending, lapping, tying and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour charges, cost of binding wire, transportation charges for all materials to worksite, all other items required for the work and tools etc. complete. |
| 2044 | Unloading Platform |
| 2045 | Control Building |
| 2046 | Fire Water Pump House |
| 2047 | Marine Approach Trestle |
| 2048 | Supply, Fabricating and erection of structural steel work in rolled sections like joists, channels, angles, tees and trusses. RHS, SHS, or CHS etc. with caps, bases mild steel plates, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawing or as directed including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and hot dip galvanizing as per technical specifications.Weight of bolt / welding shall Not be considered for payment. Welding shall be done by approved electrodes only . |
| 2049 | Fire Water Pump House |
| 2050 | Marine Approach Trestle |
| 2051 | Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S.bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia or more upto 32mm at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. |
| 2052 | Marine Approach Trestle |
| 2053 | Supply, fabricating and fixing of embedments, MS inserts,pipes,sleeves, flats, guide rails, angle / beamspieces, rungs of various diameters, plates of dimensions as requiredincluding cost of all labour, materials and equipment, transportation, loading, unloading, handling, welding, cutting, drilling, scaffolding and setting complete as per specifications, drawings and as directed by PMC Engineer/ Owner. |
| 2054 | Fire Water Pump House |
| 2055 | Marine Approach Trestle |
| 2056 | SECTION 2 : ONSHORE CIVIL WORKS |
| 2057 | AREA CLEARANCE Area clearance including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 300 mm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2058 | BACK FILLINGFilling available excavated earth (excluding rock), in foundations and plinths, with Normal soil in layers of 150mm thickness, including watering, ramming well with mechanical roller / rammers and consolidating etc. complete, as per specifications, drawings and as directed by PMC Engineer/ Owner. |
| 2059 | Admin Cum Control Building |
| 2060 | Box Culvert |
| 2061 | Pipe Trestle |
| 2062 | Boundary Wall |
| 2063 | Warehouse Building |
| 2064 | DG Shed |
| 2065 | Underground Tank |
| 2066 | Nitrogen Facility |
| 2067 | Road |
| 2068 | Recharge Pit |
| 2069 | Lighting Post |
| 2070 | Pipe Bridges PB1, PB2 & PB3 |
| 2071 | EXCAVATION for foundation in earth, soil of all types, sand, gravel and soft murrum, including removing the excavated material up to a distance of 1.0 km. beyond the building area & stacking and spreading as directed within the yard area, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete as per specification and as directed by PMC Engineer/ Owner. Payment will be paid as per PCC Plan area for lift more than 3.0m. |
| 2072 | Admin Cum Control Building |
| 2073 | Box Culvert |
| 2074 | Pipe Trestle |
| 2075 | Boundary Wall |
| 2076 | Warehouse Building |
| 2077 | DG Shed |
| 2078 | Underground Tank |
| 2079 | Nitrogen Facility |
| 2080 | Road |
| 2081 | Recharge Pit |
| 2082 | Lighting Post |
| 2083 | Pipe Bridges PB1, PB2 & PB3 |
| 2084 | Providing & laying Plain Cement Concrete (PCC) of Grade M10 with 20 mm and down size graded machine crushed stone aggregate including placing, compacting, finishing the surface in smooth finish to the correct level and curing with contractors labour, materials, plants, machinery and equipment with all lead and lift including shuttering compacting and curing etc. complete as per specification and as directed by PMC Engineer/ Owner. |
| 2085 | Nitrogen Facility |
| 2086 | Road |
| 2087 | Providing & laying Plain Cement Concrete (PCC) of Grade M20 with 20 mm and down size graded machine crushed stone aggregate including placing, compacting, finishing the surface in smooth finish to the correct level and curing with contractors labour, materials, plants, machinery and equipment with all lead and lift including shuttering compacting and curing etc. complete as per specification and as directed by PMC engineer/ Owner. |
| 2088 | Admin Cum Control Building |
| 2089 | Box Culvert |
| 2090 | Pipe Trestle |
| 2091 | Boundary Wall |
| 2092 | Warehouse Building |
| 2093 | DG Shed |
| 2094 | Underground Tank |
| 2095 | Nitrogen Facility |
| 2096 | Recharge Pit |
| 2097 | Lighting Post |
| 2098 | Pipe Bridges PB1, PB2 & PB3 |
| 2099 | Providing cast – in situ reinforced cement concrete of design mix grade M35 in accordance with IS 456 (Latest Edition) using coarse aggregate, sand and 53 grade Ordinary Portland cement confirming to IS 455, as per design mix in cast-in-situ for portion of beams, slabs, Column etc forAdmin cum Control Building, Pipe trestle, Boaundary wall, warehouse bulding, etc. as indicated in the drawing, excluding cost of fabrication, fixing of reinforcement,but including cost of cement, stone chips, sand, cost of all labour charges, mixing, centering and shuttering,conveying, placing, consolidation, screening and washing of coarse aggregate and sand, transportation charges of all materials to the Work Site, hire charges and running charges of batching plant, vibrator, consumables and all other equipment, cost of tools etc. complete including curing. (The design mix shall be provided by the contractor from the approved laboratory of Govt. of India/ IITs/ NITs/ NABL Accredited Labs). |
| 2100 | Admin Cum Control Building |
| 2101 | Box Culvert |
| 2102 | Pipe Trestle |
| 2103 | Boundary Wall |
| 2104 | Warehouse Building |
| 2105 | DG Shed |
| 2106 | Underground Tank |
| 2107 | Nitrogen Facility |
| 2108 | Lighting Post |
| 2109 | Pipe Bridges PB1, PB2 & PB3 |
| 2110 | Supply, deliver and transportation of reinforcement steel with a minimum yield strength of 500 N/mm2 and minimum elongation of 16% or equivalent confirming to IS 1786 with corrosion resistant element for Fabrication and fixing of reinforcement in superstructure worksfor Admin cum Control Building, Pipe trestle, Boaundary wall, warehouse bulding, etc including cost of fabrication & fixing, cost of corrosion resistant deformed bars, all handling charges, cutting, bending, lapping, tying and welding in position wherever necessary with black 18 SWG annealed binding wire, all labour charges, cost of binding wire, transportation charges for all materials to worksite, all other items required for the work andtools etc. complete. |
| 2111 | Admin Cum Control Building |
| 2112 | Box Culvert |
| 2113 | Pipe Trestle |
| 2114 | Boundary Wall |
| 2115 | Warehouse Building |
| 2116 | DG Shed |
| 2117 | Underground Tank |
| 2118 | Nitrogen Facility |
| 2119 | Lighting Post |
| 2120 | Pipe Bridges PB1, PB2 & PB3 |
| 2121 | Supply, Fabricating and erection of structural steel work in rolled sections like joists, channels, angles, tees and trusses. RHS, SHS, or CHS etc. with caps, bases mild steel plates, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawing or as directed including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and hot dip galvanizing as per technical specifications.Weight of bolt / welding shall Not be considered for payment. Welding shall be done by approved electrodes only. |
| 2122 | Boundary Wall |
| 2123 | DG Shed |
| 2124 | Pipe Bridges PB1, PB2 & PB3 |
| 2125 | Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S.bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia or more upto 32mm at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. |
| 2126 | DG Shed |
| 2127 | Pipe Bridges PB1, PB2 & PB3 |
| 2128 | Supply, fabricating and fixing of embedments, MS inserts,pipes,sleeves, flats, guide rails, angle / beamspieces, rungs of various diameters, plates of dimensions as requiredincluding cost of all labour, materials and equipment, transportation, loading, unloading, handling, welding, cutting, drilling, scaffolding and setting complete as per specifications, drawings and as directed by PMC Engineer/ Owner. |
| 2129 | DG Shed |
| 2130 | Pipe Bridges PB1, PB2 & PB3 |
| 2131 | MISCELLANEOUS ITEMS |
| 2132 | PREPARING SUB GRADE WITH ROAD ROLLERPreparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 centimetre depth, dressing to camber and consolidating with road roller to achieve minimum of 95% proctor density including making good the undulations etc. And re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres all complete as per specification and direction of PMC Engineer. |
| 2133 | Road |
| 2134 | WET MIX MACADAMProviding & laying 225mm thick WMM with well graded crushed stone aggregate including placing, compacting as per IRC:58to the correct level and curing with contractors labour, materials, plants, machinery and equipment with all lead and lift including shuttering compacting and curing etc. complete as per specification and as directed by PMC Engineer. |
| 2135 | Road |
| 2136 | RCC PAVINGProviding & laying 300mm thick RCC Pavment (M30 Grade) with well graded crushed stone aggregate including placing, compacting to the correct level and curing with contractors labour, materials, plants, machinery and equipment with all lead and lift including shuttering compacting and curing etc. complete as per specification and as directed by PMC Engineer/ Owner. |
| 2137 | Nitrogen Facility |
| 2138 | SAND FILLINGProviding & laying 150mm thick sand above well compacted sub grade as per IRC:58 with with contractors labour, materials, plants, machinery and equipment with all lead and lift including compacting and curing etc. complete as per specification and as directed by PMC Engineer/ Owner. |
| 2139 | Road |
| 2140 | CONCRETE PAVERS IN ROAD SHOULDER AREALaying and fixing of 100mm thick, M40 grade cement concrete pavers blocks including 40mm thick sand bedding and gap between blocks shall be filled with well sieved fine sand, compaction with vibratory plate compactors as per IRC:SP:63-2004, cleaning the top surface for any debris, blocks etc. including materials, labours, tools, tackles and plants complete as per specifications and as directed by PMC Engineer/ Owner. |
| 2141 | Road |
| 2142 | ARCHITECTURAL WORKS |
| 2143 | JETTY CONTROL BUILDING |
| 2144 | Brick Work (Rate is inclusive of curing of masonry including supplying & providing water, scaffolding as required & associated labour) |
| 2145 | Brick work with Class Designation 50 bricks in Cement mortar 1:4 (1 cement : 4 coarse sand) in superstructureABOVE PLINTH ANDUP TO FLOOR V LEVEL |
| 2146 | Half brick masonry (115 mm thick) with Class designation 50 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructureABOVEPLINTH & UP TO FLOOR V LEVEL inlcuding providing and placing in position 2 Nos. 6mm dia. M.S. bars, includingproviding 75mm thk. horizontal band in CC mix 1:2:4 atevery third course of half brick masonry. |
| 2147 | Plastering & FinishingNote: a. Rate is inclusive of curing of plaster including supplying & providing water, scaffolding as required & associated labour.Providing and laying cement plaster on surfaces with Coarse/ Fine sand (as applicable) including curing, scaffolding etc. |
| 2148 | In 18 mm thick cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
| 2149 | In 12 mm thick Cement plaster of mix1:4 (1 cement: 4 coarse sand) |
| 2150 | In 6 mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 2151 | Providing and fixing 150 mm wide 24 SWG Chicken Wire mesh between junctions of column/beam and walls, fixed with U nails 150 mm centre to centre before plastering the junction. |
| 2152 | Painting & Finishing (including Scaffolding & Curing)Note: All rates are inclusive of executing in a required pattern to be approved by IOC & all colour shades to be used as part of the pattern. |
| 2153 | Providing and applying plaster of Paris putty of 2 mm average thickness over plastered surface to prepare the surface even and smooth complete |
| 2154 | Applying one coat of Acrylic emulsion compatible primer of approved brand and make on wall surface & painting with silicon & acrylic emulsion based water thinnable interior paint with 2 or more coats. |
| 2155 | Finishing walls with Acrylic Smooth exterior paint (Anti-fungus & Weatherproof) of required shade with Two or more coat applied @ 1.67 ltr/10 sqm over & including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 2156 | Melamine polishing on wood work (one or more coat). |
| 2157 | Flooring & FinishingNote:a. Payment shall be made on finished floor area/ dado/ skirting & finishing only. No extra payment shall be made towards additional thickness of bedding to match level of adjoining floors.b. Flooring shall be laid including patterns/ all colours to be provided during execution of works & as such cost quoted to include the same.c. Sample of Granite/Kota stones, Tiles, flooring sheets, wooden panel floors etc shall be approved by Site Engineer before ordering & delivering to site.d. Job includes supplying & providing water for curing as applicable. |
| 2158 | Providing 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm Nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix :2gradedstoneaggregate6mmNominalsize)byvolume, hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, 2mm thick PVC strip at desired spacing, cost of Nosing in steps Complete.Note: Item rate includes supplying and providing skin reinforcement in weld mesh 3 mm dia, 50 mm x 50 mm square to be provided in 40 mm thick CC floor mentioned above. |
| 2159 | Providing Shock/Sound/Fire proof/ Anti-slip/ Hard wearing/floor made of Rubber (recycled SBR) mat of approved make & Nominal thickness 20 mm over Structural flooring in Control Room area including laying, jointing with adhesives, finsihing etc complete & as per the directions of the PMC Engineer/ Owner |
| 2160 | Supplying & Providing Stone flooring with 18mm thick Granite stone (sample of stone shall be approved by Site Engineer) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry including polishing.Note: Item rate includes providing Mirror polishing to the exposed surface of the Granite stone & also grey cement slurry mixed with pigment to match the shade of Granite stone. |
| 2161 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished) machine cut for kitchen platforms, vanity counters,sills, jambs, soffits, facias, dado, skirting, risers & similar locations of required size of shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment,epoxy touch ups, including rubbing,curing moulding & polishing to edge to give high gloss finish etc. complete at all levels.Note:a. Item rate includes providing Mirror polishing to the exposed surface of the Granite stone & also grey cement slurry mixed with pigment to match the shade of Granite stone.b. Item rate also includes providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters & similar location in Granite/stone work including necessary holes for pillar taps etc.including rubbing and polishing of cut edges etc.complete |
| 2162 | Providing and laying Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing wax polishing complete.Note: Item rate includes providing Kota stone in treads of steps and risers using single length (Not exceeding 2 m). |
| 2163 | Providing & laying vitrified floor tile (10-12 mm thick as per manufactirer) in different sizes with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand, including grouting the joints with white cement and matching pigments etc., complete for flooring/skirting as specified.Note: a. For WC area, the tiles shall be Anti-skid type at No extra cost to IOC. |
| 2164 | Flooring with size of Tiles up to 60 x 60 CM in cement mortar 1:4 |
| 2165 | Skirting/ Dado with size of Tiles up to 60 x 60 CM in cement mortar 1:3 |
| 2166 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness as specified by the manufacturer ) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Site Engineer in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade. |
| 2167 | Providing and fixing with 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of PMC Engineer. |
| 2168 | Flooring Tiles with size up to 60 x 60 CM in 10 mm thick cement mortar 1:4 |
| 2169 | Skirting/ Dado Tiles with size up to 60 x 60 CM in 12 mm thick cement mortar 1:4 |
| 2170 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 2171 | Supply and Installation of “Kebao” Access Type False flooring system with accessories:Supply of FS 800 “Kebao” Steel Cement Cavity Flooring system (Imported) manufactured by M/s. KebaoInternational Industrial Group Ltd. (Shanghai) of Tile size 600mm x 600mm x 35mm thick. Finish-Topcovering with 1mm high pressure antistatic hot pressed laminate. Edge bonded with black conductive PVCbeading factory finish. The finish height of floor will be 600mm. Point Load 360Kgs UDL 1600Kgs (as perspecification). |
| 2172 | Supplying & Installing of Kebao Access Type False flooring system (Bare Finish):-Supply of FS 800 “Kebao” Steel Cement Cavity Flooring system (Imported) manufactured by M/s. Kebao International Industrial Group Ltd. (Shanghai) of Tile size 600mm x 600mm x 33mm thick. Bare finish with gray colour special weather coating on tile. Edge bonded with black conductive PVC beading factory finish. The finish height of floor will be 600 mm. Point Load 360 Kgs. Uniform Load 1600 Kgs (as per manufacture specification). |
| 2173 | Light weightFilling (Toilet / Pantry) as per IS 9142 |
| 2174 | Doors/ Windows/ Ventilators/ Partitions/ False Ceiling/ Rolling Shutter/ Grills/ Gates/ Structural Steel/ Fencing/ Roof sheeting/ SS Hand railing worksNote:a. All Aluminium sections to be used shall be out of Magnesium Silicon Alloy with matt finish & with aNodised film of approved colour of thickness Not less than 15 microns.b. Alluminium doors and windows shall be fixed on granite/ marble framework. The items shall also include providing and fillingapprovedsilicon sealant as required to ensurewater tightness,protection ofinstalled items.c. No extra payment will be made towards wastage. |
| 2175 | Providing & Fixing 15mm thick densified regular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone/cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably spaced at joints to get requiredlengthandofsize24x38mm madefrom 0.33mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross \"T\" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main\"T\" at 600mm centre to centre to form a grid of 1200x600mm and secondary cross \"T\" of length 600mm andsize 24 x28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600mm panel to from grid of size 600x600mm resting on periphery walls / partitions on Perimeterwall angle pre- coated steel of size(24x24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges calcium silicate ceiling tiles of approved texture (Spintone/Cosmos/hexa) in the grid including,cutting/ making opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc., wherever required, Main \"T\" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size 85x30x0.8 mm spaced at 1200mm centre to centre along main\"T\", bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint for all heights,as per specifications,drawings & as directed by engineer-in- charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames /opening (cut outs) having area less than 0.30 sqm.The calcium silicate tile shall have NRC value |
| 2176 | of 0.50(Minimum), light reflection > 85%, Non - combustible as per B.S. 476 part IV, 100% humidity resistance & also having thermal conductivity<0.043 w/m 0 KC |
| 2177 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mmlong dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture\"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 1 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 2178 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed and fixed in position with Sal wood |
| 2179 | Providing and fixing panelling or panelling and glazing in panelled or panelled & glazed shutters using Decorative plywood ,5 ply, 9 mm thick both side decorative veneer (Type 1) conforming to IS 1328 BWR type for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 2180 | Providing & fixing ISI mark flush door shutters with 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains/cross bands & face veneers on both faces of shutters |
| 2181 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be ANodized, Coloured, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of PMC Engineer. (Cost of glazing or panels to be paid for separately) |
| 2182 | For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 2183 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of PMC Engineer . (Cost of aluminium snap beading shall be paid in basic item): |
| 2184 | With float glass panes of 4.0 mm thickness |
| 2185 | With float glass panes of 6.0 mm thickness |
| 2186 | Providing and fixing double action hydraulic floor spring With stainless steel cover plate of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot & single piece M.S. sheet outer box with slide plate etc. complete as per the direction of PMC Engineer/ Owner |
| 2187 | Providing and fixing aluminium handles, ISI marked, aNodised (anodic coating Not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.1 125 mm |
| 2188 | Providing and fixing aluminium tower bolts, ISI marked, aNodised (aNodic coating Not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.4 150x10 mm |
| 2189 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 2190 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :9.74.2 200x10 mm |
| 2191 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of PMC Engineer (Door handle, Pivot, lock and stopper etc. are included in the item except Floor spring).Note: a. Rate to include water tight sealing of glass to glass joints with Sillicone sealants whereever applicable.b. Glazing of Control room West side is to be operated under same item at No extra cost to IOC including all SS clamps/ brackets between glass panels. |
| 2192 | Providing & fixing fire resistant door frame of section 143x57mm having built in rebate made out of 16 S.W.G. GI sheet (zinc coating Not less than 120gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10X4 mm (minimum) alround the frame & fixing with dash fastner of approved brand fire resistant primer etc. complete as per direction. (Dash fastner to be paid seperately. |
| 2193 | Providing and fixing 50mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Site In-Charge, with suitable munting on door frame consisting of vertical stiles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I. sheet (zinc coating Not less than 120gm/sqm, duly filled FR insulationmaterial and fixing withnecessary S.S. ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. complete as per direction of PMC Engineer/ Owner (panelling to be paid for seperately. |
| 2194 | Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc. with with clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance, G.I. beadingof appropriate size made out of 20mm G.I. sheet (zinc coating Not less than 120gm/sqm), fire resistant sealant, including applying a coat off fire resistant primer on G.I. beading etc., complete in all respect as per direction of PMC Engineer/ Owner |
| 2195 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating Not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of Not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall Not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 2196 | Providing and fixing panic bar/ latch (double point) fitted with a single body, Trim Latch and Lock on back side of Panick Latch of approved brand having minimum 60 minutes fire resistance. |
| 2197 | Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire as per IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover.Note: Item rate includes mechanical device chain and crank operation for operating rolling shutters. |
| 2198 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in- charge.(area of grill to be measured). |
| 2199 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 2200 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system Not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 2201 | Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge. |
| 2202 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. |
| 2203 | (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. |
| 2204 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the PMC Engineer. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 2205 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of PMC Engineer all complete. |
| 2206 | Providing & Fixing GRC Jali |
| 2207 | Supplying & Installation of Passenger Lift(6 persons) |
| 2208 | FIREWATER PUMPHOUSE AND ONSHORE BUILDINGS |
| 2209 | BRICK MASONRYNote:Rate is inclusive of curing of masonry including supplying & providing water, scaffolding as required & associated labour.Brick work with Class Designation 50 bricks in Cement mortar 1:4 (1 cement : 4 coarse sand) in superstructureABOVE PLINTH ANDUP TO FLOORLEVEL |
| 2210 | Admin Cum Control Building |
| 2211 | Boundary Wall |
| 2212 | Warehouse Building |
| 2213 | Jetty-FWPH Structure |
| 2214 | Recharge Pit |
| 2215 | Half brick masonry (115 mm thick) with Class designation 50 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructureABOVEPLINTH & UP TO FLOOR LEVEL inlcuding providing and placing in position 2 Nos. 6mm dia. M.S. bars, includingproviding 75mm thk. horizontal band in CC mix 1:2:4 atevery third course of half brick masonry. |
| 2216 | Admin Cum Control Building |
| 2217 | PLASTERING & FINISHINGNote: Rate is inclusive of curing of plaster including supplying & providing water, scaffolding as required & associated labour.In 18 mm thick cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
| 2218 | Admin Cum Control Building |
| 2219 | Warehouse Building |
| 2220 | Jetty-FWPH Structure |
| 2221 | In 12 mm thick Cement plaster of mix1:4 (1 cement: 4 coarse sand) |
| 2222 | Admin Cum Control Building |
| 2223 | Warehouse Building |
| 2224 | Jetty-FWPH Structure |
| 2225 | In 6 mm thick plaster of mix 1:3 (1 cement: 3 fine sand) in ceiling |
| 2226 | Admin Cum Control Building |
| 2227 | Warehouse Building |
| 2228 | Jetty-FWPH Structure |
| 2229 | PAINTING & FINISHING (INCLUDING SCAFFOLDING & CURING)Note: All rates are inclusive of executing in a required pattern to be approved by IOC & all colour shades to be used as part of the pattern. |
| 2230 | Applying one coat of Acrylic emulsion compatible primer of approved brand and make on wall surface & painting with silicon & acrylic emulsion based water thinnable interior paint with 2 or more coats. |
| 2231 | Admin Cum Control Building |
| 2232 | Warehouse Building |
| 2233 | Jetty-FWPH Structure |
| 2234 | Finishing walls with textured exterior paint (Anti-fungus & Weatherproof) of required shade with Two or more coats applied @ 3.28 ltr/10 sqm, over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 2235 | Admin Cum Control Building |
| 2236 | Warehouse Building |
| 2237 | Jetty-FWPH Structure |
| 2238 | FLOORING & FINISHINGNote:a. Payment shall be made on finished floor area/ dado/ skirting & finishing only. No extra payment shall be made towards additional thickness of bedding to match level of adjoining floors.b. Flooring shall be laid including patterns/ all colours to be provided during execution of works & as such cost quoted to include the same.c. Sample of Granite/Kota stones, Tiles, flooring sheets, wooden panel floors etc shall be approved by Site Engineer before ordering & delivering to site.d. Job includes supplying & providing water for curing as applicable. |
| 2239 | Providing 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm Nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix :2gradedstoneaggregate6mmNominalsize)byvolume, hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, 2mm thick PVC strip at desired spacing, cost of Nosing in steps Complete.Note: Item rate includes supplying and providing skin reinforcement in weld mesh 3 mm dia, 50 mm x 50 mm square to be provided in 40 mm thick CC floor mentioned above. |
| 2240 | Admin Cum Control Building |
| 2241 | Jetty Unloading Platform |
| 2242 | Warehouse Building |
| 2243 | DG Shed |
| 2244 | Jetty-FWPH Structure |
| 2245 | Providing and laying Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing wax polishing complete.Note: Item rate includes providing Kota stone in treads of steps and risers using single length (Not exceeding 2 m). |
| 2246 | Admin Cum Control Building |
| 2247 | Providing & laying vitrified floor tile (10-12 mm thick as per manufactirer) in different sizes with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand, including grouting the joints with white cement and matching pigments etc., complete for flooring/skirting as specified.Note: a. For WC area, the tiles shall be Anti-skid type at No extra cost to IOC. |
| 2248 | Flooring with size of Tiles up to 60 x 60 CM in cement mortar 1:4 |
| 2249 | Admin Cum Control Building |
| 2250 | Skirting/ Dado with size of Tiles up to 60 x 60 CM in cement mortar 1:3 |
| 2251 | Admin Cum Control Building |
| 2252 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness as specified by the manufacturer ) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Site Engineer in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade. |
| 2253 | Admin Cum Control Building |
| 2254 | Providing and fixing with 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Site Engineer. |
| 2255 | Flooring Tiles with size up to 60 x 60 CM in 10 mm thick cement mortar 1:4 |
| 2256 | Admin Cum Control Building |
| 2257 | Skirting/ Dado Tiles with size up to 60 x 60 CM in 12 mm thick cement mortar 1:4 |
| 2258 | Admin Cum Control Building |
| 2259 | DOORS/ WINDOWS/ VENTILATORS/ PARTITIONS/ FALSE CEILING / ROLLING SHUTTER/GRILLS/ GATES/FENCING/ROOF SHEETING /SS HAND RAILING WORKSNote:a. All Aluminium sections to be used shall be out of Magnesium Silicon Alloy with matt finish & with aNodised film of approved colour of thickness Not less than 15 microns.b. Alluminium doors and windows shall be fixed on granite/ marble framework. The items shall also include providing and fillingapprovedsilicon sealant as required to ensurewater tightness,protection ofinstalled items.c. No extra payment will be made towards wastage. |
| 2260 | Providing & Fixing 15mm thick densified regular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone/cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably spaced at joints to get requiredlengthandofsize24x38mm madefrom 0.33mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross \"T\" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main\"T\" at 600mm centre to centre to form a grid of 1200x600mm and secondary cross \"T\" of length 600mm andsize 24 x28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600mm panel to from grid of size 600x600mm resting on periphery walls / partitions on Perimeterwall angle pre- coated steel of size(24x24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges calcium silicate ceiling tiles of approved texture (Spintone/Cosmos/hexa) in the grid including,cutting/ making opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc., wherever required, Main \"T\" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size 85x30x0.8 mm spaced at 1200mm centre to centre along main\"T\", bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint for all heights,as per specifications,drawings & as directed by PMC Engineer. |
| 2261 | Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames /opening (cut outs) having area less than 0.30 sqm.The calcium silicate tile shall have NRC value of 0.50(Minimum), light reflection > 85%, Non - combustible as per B.S. 476 part IV, 100% humidity resistance & also having thermal conductivity<0.043 w/m 0 KC |
| 2262 | Admin Cum Control Building |
| 2263 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be ANodized, Coloured, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Site In-Charge. (Cost of glazing or panels to be paid for separately) |
| 2264 | Admin Cum Control Building |
| 2265 | Warehouse Building |
| 2266 | Jetty-FWPH Structure |
| 2267 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Site In-Charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 6.0 mm thickness |
| 2268 | Admin Cum Control Building |
| 2269 | Warehouse Building |
| 2270 | Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire as per IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover.Note: Item rate includes mechanical device chain and crank operation for operating rolling shutters. |
| 2271 | Admin Cum Control Building |
| 2272 | Warehouse Building |
| 2273 | Jetty-FWPH Structure |
| 2274 | Providing & fixing fire resistant door frame of section 143x57mm having built in rebate made out of 16 S.W.G. GI sheet (zinc coating Not less than 120gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10X4 mm (minimum) alround the frame & fixing with dash fastner of approved brand fire resistant primer etc. complete as per direction. (Dash fastner to be paid seperately. |
| 2275 | Admin Cum Control Building |
| 2276 | SECTION 4: PLUMBING, WATER SUPPLY, SEWERAGE AND STORM DRAINAGE WORKS |
| 2277 | Supply , Installation, testing, commissioning of Package Type Sewage Treatment Plant of Capcity 3 KLD in FRP . The STP compries of (1) Primary settling tank 2) Aeration Zone (3)secondary Sedimentation Zone, 4) Transfer Pumps 5)MBBR Media 6) Electrical Cable, earthing, Panel 7) Diffusers 8) Manhole, 9) uPVC Pipes 10) Manhole Cover 11) Collection Tank 12) Bar Screen 13) Air Blower and any other accessriers to complete the work. |
| 2278 | Supply , Installation, testing, commissioning of Package Type Sewage Treatment Plant of Capcity 1 KLD in FRP . The STP compries of (1) Primary settling tank 2) Aeration Zone (3)secondary Sedimentation Zone, 4) Transfer Pumps 5)MBBR Media 6) Electrical Cable, earthing, Panel 7) Diffusers 8) Manhole, 9) uPVC Pipes 10) Manhole Cover 11) Collection Tank 12) Bar Screen 13) Air Blower and any other accessriers to complete the work. |
| 2279 | Supply , Installation, testing, commissioning of Sewage Collection Tank in FRP 2000 mm (Dia) X 1200 MM (Height) |
| 2280 | Supply , Installation, testing, commissioning of Treated Water Tank in FRP 2000 mm (Dia) X 1200 MM (Height) |
| 2281 | Supply , Installation, testing, commissioning of skid mounted Potable Water pumps in SS 304 with capcity 1.0 m3/hr @ 30 m heard |
| 2282 | Erection, Testing & Commissioning the following sizes of Gun Metal Gate Valves as per Specification |
| 2283 | 50 mm dia |
| 2284 | Erection, Testing & Commissioning the following sizes ofGun Metal Check Valves as per Specification |
| 2285 | 50 mm dia |
| 2286 | Supply and laying above ground/underground threaded MS Galvanized Pipes including all fittings as per IS 1239 |
| 2287 | 50mm dia |
| 2288 | Supplying and providing Porta Cabin of size 3M x 3M x 2.5 M with Toilet Inbuilt with EWC & washbasin including provision of door, windows, AC, lighting, furnishers, flooring etc as per description in Technical Specification with Transporation etc complete. |
| 2289 | PART-D - COMMISSIONING & HAZOP STUDY |
| 2290 | HAZOP STUDY |
| 2291 | Carrying out HAZOP study for the equipment, Pipe line and associated systems, Recommending modification as required, Preparation of Report by Chairman of HAZOP Study. |
| 2292 | COMMISSIONING |
| 2293 | Successful Commissioning activity for Loading / Unloading of Vessels, Pigging, etc. subsequent to completion of individual Equipment and System commissioning acitivities including the following: a) Review of commissioning status, jointly with Owner personnel and obtaining all required Clearences.b) All necessary coordination/ liaison with IOCL/KPL/Statutory Authorities etc. forcompleting the planned operations including deputing necessary engineers of various disciplines along with supervisory staffs/blue collar workmen.The deployment plan to be submitted in advance prior to commissioning and approved by IOCL. |
| 2294 | For LPG Vessels (2 Nos.) |
| 2295 | For POL Vessels (2 Nos.) including Pigging of Pipelines post vessel Unloading/Loading Operations |