Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe House Area ( Jcb, Zone B, Cacosa, Kashmir House Area ) Under Ge I Rnd Delhi Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe, Delhi-Delhi

Military Engineer Services-MES has published Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe House Area ( Jcb, Zone B, Cacosa, Kashmir House Area ) Under Ge I Rnd Delhi Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe. Submission Date for this Tender is 12-10-2021. Air Conditioner Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29140700
Corrigendum : Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe House Area ( Jcb, Zone B, Cacosa, Kashmir House Area ) Under Ge I Rnd Delhi Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe
Open Tender
Indian
Delhi
Delhi
12-10-2021

Tender Details

Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe House Area ( Jcb, Zone B, Cacosa, Kashmir House Area ) Under Ge I Rnd Delhi Repair / Maintenance Of Summer Appliances And Other Connected Works At Metcalfe House Area ( Jcb, Zone B, Cacosa, Kashmir House Area ) Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Sep-2021 Corr1 Date 04-10-2021
2 25-Sep-2021 CORR2 BOQ 04-10-2021
3 04-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-10-2021
4 11-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/ MAINTENANCE OFSUMMER APPLIANCES AND OTHER CONNECTED WORKS AT METCALFE HOUSE AREA (JCB, ZONE B, CACOSA, KASHMIR HOUSE AREA) UNDER GE I RND DELHI
Sl. No. Item Description
1M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
2All same as per ser item No 1.00 above but for split type AC/Inverter type AC 1.5/2.0/3.0/4.1 Ton
3All same as per ser item No. 1.00 above but for VRF inverter split type 3 phase AC of capacity 7.5 TR.
4M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacityof approved Make and required Size to suit existing AC including taking out the unservice-cable Fan Motor from the AC complete all as specified and directed.
5All same as per srl Item No. 4.00 above but AC(Window/Split Type). 2.0 TR Capacity
6M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding complete all as specified anddirected.
7M&L in replacement Air circular BlowerFan Motor ofAC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unserviceableAir circular BlowerFan Motor complete all as specified and directed.
8M&Lin replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filterfrom AC complete all as specified and directed.
9M&Lin replacement Air Filtersuitable of AC (Split type)1.5 TR to 3.0 TR Capacityincluding taking out unserviceableAir Filtercomplete all as specified and directed.
10M&Lin replacementCapacitorRunning 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type)1.5 TR/2.0 TR Capacity and of any make includingtaking out unserviceableCapacitor from ACcomplete all as specified and directed.
11M&L in replacement Capacitor Starting80 mfd – 120 mfd suitable for old ones AC(Window/Split Type)1.5 TR/2.0 TR Capacity and of any make including taking out unserviceableCapacitorfrom ACcomplete all as specified anddirected.
12M&L in replacement Fan MotorBlades AC (Window/Split type)1.5/2.0 TR capacity including taking out unserviceable Blades of FanMotor from AC complete all as specified and directed.
13M&Lin replacement Fan MotorCapacitor 4 mfd of suitable for new/star ratedAC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from ACcomplete all as specified anddirected.
14M&L Fan Motor in replacementCapacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0/3.0TR capacity including taking our unserviceable Fan motor capacitor from ACcomplete all as specified and directed.
15M&Lin replacement Front Plastic Grill (as per Sample) of AC (Window type)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC complete all as specified anddirected.
16M&L in replacement Front Plastic Grillfor inner unit (asper Sample) of AC (Splittype)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC complete all as specified anddirected.
17M&L in replacement Runner for air blower motor of AC(split type)AC 1.5/2.00TR capacity (As per sample or as per site requirement)including Runner of Air Blower Motor from ACcomplete all as specified and as directed.
18M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified anddirected.
19M&L in replacement Selector Switch of AC (Window/Split Type)1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Selector Switch from ACcomplete all as specified anddirected.
20M&L in replacement Selector Switch Knob of AC(Window/ Split Type)1.5 TR/2.0/3.00 TR Capacity including taking out unserviceable Selector Switch Knob from ACcomplete all as specified and directed.
21M&L in replacement Starting Relay of AC(Window/Split Type) 1.5 TR/2.0/3.00TR Capacityincluding taking out unser-viceable Starting Relay from ACcomplete all as specified anddirected.
22M&L in replacement Strainer with Capillary Tube of ACWindow/ Split Type) 1.5 TR/2.0/3.0 TR Capacity (including taking out unserviceable Strainer with Capillary Tubefrom ACcomplete all as specified anddirected.
23M&Lin replacement Thermostat Switch of AC(Window/Split Type) 1.5 TR/2.0/3.0 TR Capacityincluding taking out unserviceable Thermostat Switch from ACcomplete all as specified and directed.
24S&F in replacement cooling coil suitable forwindow type room AC 1.5/2 ton including taking out unserviceable cooling coilof capacity 1.5/2 Ton.as per sample.
25S&F in replacementCondensing coil suitable forwindow type AC 1.5/2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton
26S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity upto 2 ton.
27S & F in replacement cooling coil suitable for split type ACincluding taking out unserviceable cooling coilup to capacity 2 ton.
28S&F in replacement Indoor unit suitable for 1.5 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
29S&F in replacement outdoor unit suitable for 1.5 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
30S&F in replacement Indoor unit suitable for2 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
31S&F in replacement outdoor unit suitable2 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
32Suuply & Fix in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton.
33All same as per ser item No. 32 here-in-before but for split/ window type AC capacity 2.0 Ton.
34All same as per ser item No. 32.00 above but for split type AC capacity 3.0 Ton three phase run.
35Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 includingre-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed.
36All same as per Item No. 35.00 above but AC 2.0 TR Capacity (Window/Split Type).
37M&L in replacement PCB with remote and sensor for windowtype AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
38M&L in replacement PCB with remote including sensorfor Split type AC 2.0 to 3.0 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
39M&L in replacement PCB & motherboard with remotecomplete setforInverter Split type AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
40M&L in replacement Remoteof AC ( Window/Split Type) 1.5/2.0 TR capacity(As per sample or as per site requirement)all as specified and as directed.
41S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit all as specified and directed.
42S&F in replacement gas charging pin valve complete including taking out unserviceablepin valve all as specified and directed.
43Taking out window type AC complete unit from any height/ any floor up to sixstorey buildingand shifting to another locationin the sameor other building in the complex including refixing of the unitcomplete all as specified and directed.
44Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to sixstorey buildingbyincluding pumping down the gas into thecompressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiionin the sameor other building in the complex including refixing of the unit complete all as specified and directed.
45Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacityincluding testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogengas complete all as specified and directed.
46All same as per ser item No. 45.00 above but R- 410/32 for split type AC up to 2 TR capacity complete.
47All same as per item No 45.00 above but VRF unit 7.5 TR capacity complete.
48S&F in replacement Hermatically Sealed compressor for 300Ltrs capacity Deep freezer including bracing the sunction and discharge lines complete all specified and dircted.
49S&F in replacement of casing of window type AC including company fitted condensing & cooling coil suitable for 1.5 TR capacity complete including PCB except compressor complete.
50M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
51All ame as per ser item No. 50.00 above but 1/2"complete all as specified and directed.
52S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
53S&F in replacement compressor shut off valve 5/8" for split ACup to 2.00 toncapacity complete all as specified and directed.
54S & F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
55All same as per ser item No. 54.00 above but size 1/2" complete all as specified and directed.
56All same as per ser item No. 54.00 above but size 3/8" complete all as specified and directed.
57All same as per ser item No. 54.00 above but size 5/8" complete all as specified and directed.
58S&F in replacement High density polyethylene pipes 20 mm dia (HDPE) of pressure rating 6 kgf/cm2laid in wall/ceilingincluding all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 6 (six) storey complete all as specified and directed.
59All same as per item No. 58.00 above but size 40mm dia
60S&F in replacement of synthetic rubber foamfor insulation for refrigerant copper piping of existin size 1/4" to 5/8" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
61S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
62S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
63S&F in replacement metal plug top Single pole & Neutral and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
64S&F in repalcement metal enclosures with clad socket & plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete including of MCB SP 25 Amps 240 voltscomplete all as specified and directed.
65S&F in repalcement metal enclosures with clad socket & plug top Triple pole and earthencolsure with a three pin and earth plug with socket complete with one triple pole MCB complete including of MCB TP 63 Amps 240 voltscomplete all as specified and directed.
66S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
67S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed.
68M/L in replacement for submain wiring including PVC casing capping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn throughconduit pvc 20mm dia mediam duty with all accessories including 4.0 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and all as specified .
69S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete allas specified and as directed
70S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete allas specified and as directed
71Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstall -ing, Testing, connecting the same after replace-ment of defective/burnt Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed.
72All same as per item No. 71.00 above but but capcity 120/150 Ltrs
73M&L for servicing of water coolerof any capacity (40 Ltr to 150 Ltrs) including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
74Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
75S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
76S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
77S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
78M&L for preparation of old painted surfacesof water cooler of upto capacity 150 Ltrs by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting.
79S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
80S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
81S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
82S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
83S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
84M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
85M&L for painting ofdesert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed Note : The rates are inclusive of taking down coolerfrom any height, removal to workshop for painiting and refixing in position after painting.
86S&F in replacement of desert cooler sub mersiblewater pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing.
87S&F in replacementdesert cooler fan motor,copper wound suitable for upto 450mm sweep including metal fan blades SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing.
88S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed
89S&F in replacement plug top 3 pin 5 Amps
90S&F in replacement plug top 3 pin 15 Amps
91S&F in replacement motor capacitor 2.5/3.15/4 mfd.
92S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm.
93S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified & directed
94S&F in replacement of body made out of stainless steel sheets of of 22 gauge for bottom tank & 20 gauge for top cover of water cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified &directed
95S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified & directed
96S&F in replacement of float valve assembly with PTMTferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specifeid & directed
97S&F new wood wool pad,(Khus Khas) set of threecovered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed
98M&L for replacement of switch piano, flush type single pole, one way, 5 Amp 230 V AC ISI Marked complete all as specifed and directed
99M&L for replacement of aluminium aloy multi wing Fan blade, best qualityas per existing type and size suitable for of desert cooler complete all as specifed and directed
100Taking down Ceiling fans/exhaust fans/Wall fans, sealing cable end, dismantling blades and removing fan and blades to store and refixing the same at site after necessary repair work and painting complete all as specified and directed.
101M & L for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
102M & L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified & directed.
103All same as per item srl No 101.00 above but for exhaust fans of size 300 mm sweep to 380 mm sweep
104All same as per item srl No 101.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
105All same as per srl item No 101.00 above but for table fan/wall mounted of 450 mm sweep
106M & L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size (Bearing make/size SKF-6201/6202/ or equivalent make)
107All as per srl item No 106.00 above but for exhaust fan any of size/make- SKF 6203/6204 or equivelent make.
108M & L for replacement of rubber real of suitable size for ceiling fan complete all as specified and directed
109M & L for replacement of gun metal bush suitable for any type/model/size of fans complete all as directed.
110S&F in replacement offan step regulator, modular type 120W, 2 Module complete all as directed
111M & L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by sprayingafterfilling cavities with filler and preparation of surface complete incl marking complete all as specified & directed.
112All same as per item No 111.00 above but exhaust fan/wall fans/Pedestral fans of size 300 mmto 450 mm sweep complete.
113M & L in replacement of PVC canopy suitable for 1200 /1400 mm sweep ceiling fan complete all as directed
114Supply and fix in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase all as specified and as directed.
115Supply and fix in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase all as specified and as directed.
116Supply and fix in replacement wall mounted fan high speed 450mm sweep working on AC 240 V,50Hz, single phase complete all as specified and as directed.
117Supply and fix in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase all as specified and as directed.
118Supply and fix in replacement of exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers
119Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m
120Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
121All same as per item 120.00 above but 1400 mm sweep, min air delivery 245 CFM
122Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position.
123All same as per ser item No. 122.00 above but capacity 50 ltrs complete all as specified and directed.
124S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
125All same as per ser item No. 124.00 above but capacity 2KW complete all as specified and directed.
126S&F in replacement of thermostateas existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
127Supply and fix in replacement Oil Room Heater2900 Watt Suitable for 11 Fin,weight 18 Kgwith fan complete all as specified and as directed.of Havells Model NoOFR 11 Fin or equivalent /Bajaj/Morphy.
128Supply and fix in replacement of indicator light (Red & Green) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
129S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
130S&F in replacement of Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
131S&F in replacement of water connection CPfor inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
132S&F in replacement of Heater suitable for double door refrigerator capacity 299/310 Ltrs complete all as specified and directed.
133S&F in replacement of PVC distributors, PVC elbow & PVC Pipe best quality 15mm dia for desert cooler complete all as specifed and directed.
134S&F in replacement of Angle valves 15 mm dia cast copper alloy, screwed down, high pressure,with crutch,but fancy type, chromium plated and fixed complete all as specifed and directed.
135Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
136All same as per item srl No 135.00 above but 50 ltrs capacity
137Note for ser item No. 1 to 136 :- 1. The contractor shall provide and deploy sufficient technicians with helpers(as directedd by GE / Engineer-in-charge) and contractor"s site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints job card & complete the same complaint detailed by JE E/M/Engineer-in-charge (with in 48 hrs) 2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not completed on same day (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil and fan motor etc.) recovery will be done as follows:- (a) After 48 Hrs, Rs.1000/- Per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce machine number job card duly signed by user duly satisfactory completion of job & JE E/M to Engineer-in-charge before claiming payment. In absence of this Rs. 100/- recovery for per complaint from their dues.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail