Gujarat Cancer And Research Institute-GCARI has published Re-Tender (Short Tender)Forrate Contract For Medical Gases Supply For The Year 2021-22 & 2022-23. Submission Date for this Tender is 14-09-2021. Tanks and Cylinders Tenders in Gujarat. Bidders can get complete Tender details and download the document.
S.NO | TenderItemID | Sr. No. | Name of Item | Specification | Approx. requirement for Two years | Unit of measurement |
1 . | 1 | 1 | Medical Oxygen "A" Type Trolly Cylinder.(Gas Refilling in hospital Cylinder) | 0.75 Cum per cylinder , 1) Certified for Medical use as IP 1996 or the latest IP2) Not less than 99.0V/V of Oxygen.3) Not more than 5 PPM of CO.4) Not more than 300 PPM of CO25) Free of any kind of Halogen & Polymers.6) Free of all types of oxidizing substances.7) Absolutely free of moisture.8) Filled out of liquid from manufacturer with valid license. | 130 | Per Cubic meter |
2 . | 2 | 2 | Medical Oxygen "B" Type Ward Cylinder.(Gas Refilling in hospital Cylinder) | 1.50 Cum / 10 liter water capacity, 1) Certified for Medical use as IP 1996 or the latest IP2) Not less than 99.0V/V of Oxygen.3) Not more than 5 PPM of CO.4) Not more than 300 PPM of CO25) Free of any kind of Halogen & Polymers.6) Free of all types of oxidizing substances.7) Absolutely free of moisture.8) Filled out of liquid from manufacturer with valid license. | 5300 | Per Cubic meter |
3 . | 3 | 3 | Medical Oxygen Loose Bulk Cylinder(Vendor’s Cylinder) | 7.00 Cum/47 liter water capacity per cylinder, 1) Certified for Medical use as IP 1996 or the latest IP2) Not less than 99.0V/V of Oxygen.3) Not more than 5 PPM of CO.4) Not more than 300 PPM of CO25) Free of any kind of Halogen & Polymers.6) Free of all types of oxidizing substances.7) Absolutely free of moisture.8) Filled out of liquid from manufacturer with valid license. | 1500 | Per Cubic meter |
4 . | 4 | 4 | Medical Oxygen Bulk Cylinders in trolly mounted.(Vendor’s cylinder) | 7,7.10,7.50 Cum per cylinder Range of 35,40,44,80cylinders in Trolly, 1) Certified for Medical use as IP 1996 or the latest IP2) Not less than 99.0V/V of Oxygen.3) Not more than 5 PPM of CO.4) Not more than 300 PPM of CO25) Free of any kind of Halogen & Polymers.6) Free of all types of oxidizing substances.7) Absolutely free of moisture.8) Filled out of liquid from manufacturer with valid license. | 678000 | Per Cubic meter |
5 . | 5 | 5 | Medical Nitrous Oxide in Bulk Cylinder(Vendor’s cylinder) | 17.233 cubic meter. 17233 lit. 1) As per IP 1996/latest I.P certified as inhalation analgesic.2) Manufactured from IP grade ammonium nitrate.If any alternate technology or manufacturing process is used the same to be specified and all inputs regarding quality assurance and probable impurities etc must be provided.3) Should be contained less than 98.00% V/V of Nitrous Oxide in both Liquid and gaseous phase.4) Less than 300 PPM of CO2 impurities.5) Less than 10 PPM of CO as impurity.6) Free of Hydrogen Sulphide7) Not more than 2 PPM V/V of Nitrogen dioxide or Nitric Oxide in both liquid and gaseous phase.8) Each batch must have passes tests for alkalinity ,arsenic, phosphine, ammonia and other recommended tests. | 4360 | Per Cubic meter |
6 . | 6 | 6 | Medical Nitrous Oxide "S" Type Trolly Cylinder(Gas refilling in hospital cylinder) | 1.851 Cub Per Cylinder 1851 Ltrs. per cylinder , 1) As per IP 1996/latest I.P certified as inhalation analgesic.2) Manufactured from IP grade ammonium nitrate.If any alternate technology or manufacturing process is used the same to be specified and all inputs regarding quality assurance and probable impurities etc must be provided.3) Should be contained less than 98.00% V/V of Nitrous Oxide in both Liquid and gaseous phase.4) Less than 300 PPM of CO2 impurities.5) Less than 10 PPM of CO as impurity.6) Free of Hydrogen Sulphide7) Not more than 2 PPM V/V of Nitrogen dioxide or Nitric Oxide in both liquid and gaseous phase.8) Each batch must have passes tests for alkalinity ,arsenic, phosphine, ammonia and other recommended tests. | 26 | Per Cubic meter |
7 . | 7 | 7 | Argon Gas Cylinder | 3cum/cylinder , 1) Purity : 99.9 % min2) O2 % by Volume : 0.002 max3) H2 % by volume : 0.01 max4) Moisture (mg/l) : 0.015 max5) N2 % by Volume : 0.1 max | As and when requires | Per Cubic meter |
8 . | 8 | 8 | CO2 (Carbon Dioxide) | 6,9kg per cylinder, 1) Purity : CO2 >= 99.0%2) H2O <= 200ppm3) Odor : None4) N2O <= 2.5 ppm5) CO <= 10ppm6) H2S <= 1ppm7) NO <=2.5ppm8) SO2 <= 5ppm9) NH3 <=2.5ppm | 300 | Per Kg |
9 . | 9 | 9 | CO2 (Carbon Dioxide) | 22.5,30kg per cylinder , 1) Purity : CO2 >= 99.0%2) H2O <= 200ppm3) Odor : None4) N2O <= 2.5 ppm5) CO <= 10ppm6) H2S <= 1ppm7) NO <=2.5ppm8) SO2 <= 5ppm9) NH3 <=2.5ppm | 60 | Per kg |
10 . | 10 | 10 | Dry Nitrogen Gas Cylinder | 7 liters water capacity per cylinder, 1) Purity : N2 >= 99.02) Odor : None3) O2 <= 1.0%4) CO <= 10ppm | 1390 | Per Cubic meter |
11 . | 11 | 11 | Liquid Nitrogen Cylinders | as per capacity of tank/liter , 1) Purity : N2 >= 99.0%2) Odor :None3) CO <= 10ppm4) O2 <=1.0% | 2400 | Per liter |
12 . | 12 | 12 | ETO, Feroxide Gas | 9 kg , 1) Purity : 99.9%2) ETO : 20%3) CO2 :80% | If required | Per kg |
13 . | 13 | 13 | Liquid Medical Oxygen (LMO) | 1. Vessel capacity: 11 KL 2. Configuration – Vertical 3. Operating working pressure 8-12 kg/cm2/within safety limits as per capacity. • Vaporiser •Connection •Pressure guage repairins valve •Wight of tank | As and when requires | - |