Remaining Work Of Renovation And Alteration Of Sport Complex Situated In Fort Area, Moti Daman. (3Rd Call)(E-11598) , Daman District.-Daman And Diu

Public Works Department-PWD has published Remaining Work Of Renovation And Alteration Of Sport Complex Situated In Fort Area, Moti Daman. (3Rd Call)(E-11598) . Submission Date for this Tender is 23-09-2021. Sports Complex Tenders in Daman District. Daman And Diu. Bidders can get complete Tender details and download the document.




Tender Notice

29107805
Corrigendum : Remaining Work Of Renovation And Alteration Of Sport Complex Situated In Fort Area, Moti Daman. (3Rd Call)(E-11598)
Open Tender
Indian
Daman And Diu
Daman District.
23-09-2021

Tender Details

Remaining Work Of Renovation And Alteration Of Sport Complex Situated In Fort Area, Moti Daman. (3Rd Call)(E-11598)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Sep-2021 Corrigendum1 Date 23-09-2021

Key Value

Document Fees
INR 1500 /-
EMD
INR 2034576.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Remaining Civil, Interior and Furnishing Works at Sport Complex, Daman. (3rd Call) (estimate Cost Rs.10,34,57,560/-)
Sl. No. Item Description
1Civil work
2CIVIL WORKS: Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) R.C.C. work
3Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (ii) In Cement Mortar.
4Dismentling steel work including distempering and stacking the materials with all lead and lift.
5Providing and fixing dowel bars of minimum 32mm dia. for anchoring by drilling holes in foundation strata including necessary bending, hooking of dowel bars and grouting the holes complete as per detailed drawing and as directed.
6Clearing and grubbing road land including uproofing rank vegetation. Grass bushes, Shrubs, saplings and trees girth upto 300mm removal of stumps of trees cut earlier and disposal of unserviceable. (C) By mechanical means in area of lightjungle
7Excavation for foundation in sand, gravel, clay soft soils and murrum etc. including shoring, strutting dewatering as necessary and disposing of the excavated stuff as directed. (A)Depth upto 3.0 M. and lead upto 100m for 10 Cum
8Excavation for foundation in sand, gravel, clay soft soils and murrum etc. including shoring, strutting dewatering as necessary and disposing of the excavated stuff as directed. (B)Depth from 3.0 to 6.0 M.and lead upto 100m for 10 Cum
9Filling available excavatedearth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and watering.
10Disposal of remaining excavated Earth after filling in foundations and plinth as per direction of Engineer in-charge including loading from site and unloading at disposal site etc. complete. Lead upto 5.00 km
11Filling in foundation and plinth with sand in layers of 20 cm. Thickness including watering ramming and consolidating etc. complete.
12Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete.
13Caring out plinth treatment to post construction / existing structure by spraying chemical solution for termite controltreatment including labour and material consistent with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-IIConcentration Weight one percent is recommended i.e. one litre 20 EC chemical emulsionwith 19 litre give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5Litre chemical / Sqm of surface is recommendedas per I.S
14Providing and filling rubbles including hand packing and filling voids with sand as directed including ramming and consolidating etc. complete.
15Providing and laying cementconcrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
16Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
17Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work in Foundations,footings, Baseof columnsandMassconcrete.
18Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work inColumns, Pillars posts and struts
19Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work in RCC Tie Beams/ Beams/ Lintel/ Coping
20Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work in Slab and Weathersheds
21Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost ofcentering shuttering finishing and the cost of Waterproofing material and admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work in Walls
22Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) excluding the cost of reinforcement for reinforced concrete work in Staircase
23Providing Thermo Mechanically Treated bar (T.M.T.) (I.S.I. Mark) conforming to I.S. - 1786 Fe-500D CRS Steel including providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620- 1993/ ASTM-775M. for R.C.C. work including bending, binding and placing in position complete.
24Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm.in Cement Mortar 1:6(1- Cement : 6 -fine sand) (B)Conventional All Floor (below/above Plinth)
25Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional All Floor
26Providing and fixing Glass Doors using Teak Wood Frame of size 75 x 250 mm having 12mm thick Toughened Glass with Film of pattern and brand as approved by the Architect including fixing of all required accessaries of approved brand as per detailed drawing / as directed by Engineer In-charge etc.complete.
27Providing and fixing 38 mm thick Single Shutter Flush Doors using Teak Wood Frame of size 75 x 150 mm having BWP Shutters with both size Decorative Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper)& Heavy Stainless steel Aldrop including fixing of all other accessories of approved brand as per detailed drawing / as directed by Engineer In-charge etc. Complete.
28Providing and fixing coloured Powder Coated/Anodized Alluminium sectional windows using JINDAL Delux series 27 mm series sections having MIn. Wt 1.02 Kg /Rmt. and having Shutter of5 mm thick transperant glass and Mosquito Netsincludinganodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge.
29Providing and fixing coloured Powder Coated/Anodized Alluminium sectional windows using JINDAL Delux series 27 mm series sections having MIn. Wt 1.02 Kg /Rmt. and having Louvers of5 mm thick transperant glass and Mosquito Netsincludinganodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge.
30Curtain Wall glazing system: Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Curtain Wall glazing system with microwave cured EPDM gaskets, weather sealants of GE / Dow Corning make, baker rod, Bracketing system with MS hot dip galvanized brackets designed to accommodate three dimensional movements with washers, GI grade fasteners and anchor bolts , nylon separators to prevent bi-metallic contacts, flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. The quote rate shall include all design & shop drawing approval from architect & consultant.
31Providing and fixing Top Hung Open Out (operable) vent accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250 mm. Vent locking accessories with cremone lock and handle with 4 point locking mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions and shutter frame with Euro grooves and all joints shall be sealed with small joint sealant. The outer frame fixed to the profile system with necessary SS screws and weather sealant applied at outside and inside of profile duly Super Durable Powder coating finish of 60-80 micron thickness as per Approved shade by Architect. The stepped glass design vent shall have ceramic frit in black / colour to match the glass at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing.
32Providing and Fixing Vision Glass Panel of 6 mm Thk. Reflective HS Glass (As per Client / Architect"srequirement) in Curtain Wall Glazing System including sealing the gaps with approved sealant etc. complete.
33Providing and fixing M.S. Sliding Gates of required patternto brick walls / Columns prepared with M.S. flats, angles, Square / round bars, square pipes,at required spacingswith necessary hold fasts as per detailed drawing and fixing brick walls / coping / columns etc. complete including painting two coat & applying primer coat.
34Providing, Fabricating and fixing Structural Steel in required pattern/ design using necessary Structural Steel Sections as per detailed design/ drawings/ instructions including cutting, bending, jointing, connecting, welding and / bolting and / riveting, fabricating and erecting in position etc. complete using required Lifting arrangements including Cranes, etc. for all levels as directed including all necessary fixtures, fastening and one coat of primer and two coats of mat finished oil painting etc. complete.
35Providing and laying Lather finished Granite slab 18-20 mm (Average) thick for Doors / Windows sill & Jambs for Door, Windows and Compound Wall and Cladding as per design incl. full moulded round both edge on 10 mm thick cement mortar 1:3 (1 -cement: 3 coarse sand )jointed with grey cement slurry including rubbing and polishingetc. complete
36Providing and laying Lather finished Granite stone slab 18-20 mm thick {Single piece not more than 150 cm long} for stair steps and riser as per design incl. rounded Moulding front edge in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement: 6 coarse sand) and risers on 10 mm thick cement Plaster 1:3 (1 -cement: 3 coarse sand ) and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as per direction of Engineer In-charge.
37Providing and laying 60 cm x 60 cm MATT Vitrified Tiles(Basic Rate of ? 1000/Sq.M) flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismantling of existing flooring and jointed with colour cement slurry including finished with flush pointing & cleaning the surface and including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaningetc. complete.
38Providing and Laying swimming pool tiles 50 mm x 50 mm velvet series piccolo vitrified mosiac tilesin wall and flooring with latcrete epoxy grout in pattern etc.complate
39Providing and laying 8 mm thick Sportina GYM Flooring - BS2000 made of 85% black rubber granules and 15% synthetic EPDM granules having following specification with shade and pattern as approved by Architect etc. Complete. Density (kg/m3):1000/1200 Hardness (Shore a):68 Stretch (MPA):2.2 Abrasion resistance:0.0075g(ASTM-D4060-01) Rebound resistance:55% Friction co-efficient: trends µs:0.995 .trends µk:0.930 Shape deformation:42% Length (m):10/15/20m ±5cm Width (m):1m/1.25m ±5mm Interlocking Tiles Dimensions: 500 mm x 500 mm OR 610 mm x 610 mm
40Removing the existing sports system by grinding and scrubbing manually and Removing the undulations if required by filling CNS 50 chemicle etc.complete as per instruction of Engineer In-charge
41Providing and laying 2 mm (5 Layers) Supersoft (Hard Court) Floor for Tennis Court as per specifications and direction of manufacturer and instruction of Engineer In-charge etc. complete
42Providing and fixing vertical post, 4 mtr high, 75 mm dia. MS pipe (2mm thk. vertical post) as per dwg and horizontal pipe on top, centre and bottom of dia. 50mm (2mm thk.). Using PVC GI Mesh of size 50mmx50mmx2/3mm. The colour of the mesh is Green. Cleaning the structural sections and completing the surface preparation, applying first coats of epoxy primer @ 100 microns (withroller and brush) and second coat @ 75 microns (with roller and brush) On dry surface apply final two coats of PU Paint @ 75 microns 37.5 microns each) of approved color shade.
43Providing & Fixing of 6 Nos. 220mmx12mm dia Hilti chemical Anchor bolts with injectable mortar RE500. The base plate of size 300mmx200mmx10mm with holes drilled in it. Covering the base plate & anchors with CNS 50.
44Providing and laying in situ cement concrete M -20 with tremix treatment for 100 mm thickness groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen (including reinforcement 6mm bars vertically and horizontally) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete
45Providing and laying 3 mm (9 layers) Supersoft (Hard Court) Floor for Badminton Court as per specifications and direction of manufacturer and instruction of Engineer In-charge etc. complete
46Providing and laying 120 cm x 60 cm MATT Vitrified Tiles(Basic Rate of ? 1000/Sq.M) 8 mm thick of approved shade in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) and jointed with white cement slurry including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaningetc. complete.
47Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs.
48Providing and fixing Cobble Stone Paving as per design and pattern approved by Architest and Engineer In-Chargemechanically pressedincluding 75mm Sand layer for levelling and filling the joint with sand in proper line and level etc complete.
49Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge etc. complete.
50Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm For horizontal surface one coat @1.10 kg per sqm.
51Providing and layingbrokenchina mosaic flooringfor terrace using 12 mm to 20 mmbroken pieces ofglazed tiles to be laid over cement mortar 1:3 to plain or slope andtobe temperedtobring mortarcremeout uptosurface using white cement including rounding off junctions and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as directed.
52Providing and Fixing Glass Railing of 1.0 m height using 12 mm thick toughened Glass with a supports of Stainless Steel Sections as per design and drawings approved by Architect and instructions of Engineer in-charge including cutting, moulding, fixing in place etc. complete.
53Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
54Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brickwalls for interior plastering upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand) All Floor
55Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and soffits of stairs upto floor two leveland finished even and smooth in : (I) Cement mortar 1:3 (1 cement : 3 sand) All Floor
56Providing 20 mm thick double coat mala cement plaster on exterior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement plaster 1:2 (1 cement : 2 Coarse Sand) finished with trovel including scaffolding curing etc. Complete.
57Applying two coats of Birla or Asian acrylic lappy (putty) and two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
58Painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface & ceiling to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth etc.complete.
59Finishing wall with weather proof exterior Texture Paint of approved brand (APEX or equivalent) on wall surface (min. two coats) to give an required Texture and Shade as per approved Architectural Elevations after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc. complete as per the instructions of Architect and Engineer In-charge.
60Providing and fixing Chicken Wire Mesh/jali of 25 gauge having 150 mm minimmum width at the junctions of Brick Masonry and reinforcement cement concrete members using cement mortar of 1:3 at all height as per direction of Engineer In-charge including cutting, fixing, scaffolding etc. complete.
61Providing 12 mm wide grooves/ notch in plaster at the junctions including finishing the same at all height. etc. complete.
62Providing cement vata ( 10 cm x 10 cm size ) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete.
63ConstructingSandwich Platformof 18 mm thick Polished Black Granite at top and 30 mm thick Kota stone slab flooring fitting at bottom with cementing Materials / adhesivesincluding makingnecessary grooves in walls including all labour materialof approved qualityincl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishingetc.complete
64Providing and FixingGRC Screens having compressive strength of 35-55 MPA and Flexural Strength of 6-16 MPA as per approved design, colour, Finish by Architect and Engineer in-Charge including Packing, Transporting, Unloading, fixing at Site etc. complete.
65Providing and fixing Razor Coil fencing with min. 0.60 Metre long M.S. Angle posts 40mm x 40 mm x 6 mm and oil painting 3 coats fixed at 2.5 Mt,C/c. with five Horizontan lines and Razor Coil of galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre, strained and fixed to posts with G.I,staples including fixing the posts on Compond Wall Top in C.C 1:5:10 including finishing the surface etc complete.
66INTERIOR WORKS: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
67Providing & fixing ofWoodworks Grille with dowel made of Natural Bamboo with24mm Prelude 43 Black Exposed Grid. The Woodworks (WW) Grille panel of nominal size 57x300x2400mm comprising 6 blades of 57x16x2376mm with on center spacing of 50mm fixed thru dowel of dia-12mm x 300mm with on center spacing of 300mm and additional end dowels at 150mm from both the edges. Ledger of 6.5x24x2400mm to be used for covering face of wall angle. WW Grille should comply with ASTM-E84: Class A and have Relative Humidity of RH70. The panels are UV coated to Natural or Carbonized shades. Optional : Open edges may be covered using “Edge Caps” of 66x19x2400mm and “Blade Junction”of 66x38x2400mm to be used along the connection of two WW Grille Panels. The grid should be of “” make Prelude 43 with 24mm wide T - section flanges Black powder coating having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mmfor the main runner & the Cross Teesand with a load carrying capacity of 20 Kgs/M2. Black dowel clips of spring steel to be used for fixing panel to suspension system. INSTALLATION: To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit usingsuspension system (specifications below) at 1200mm maximum center. The First/Lastsuspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm center to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support.600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to bewall angles of size 19x19x3000mm, secured to walls at 450 mm maximum centers. Dowel clips are used to fix the panel to suspension with a grid formation of 600mm along the slat and 2 pieces along each dowel for every individual panel. SUSPENSION SYSTEM: accessories supplied byWorld Industries consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm
68Providing & fixing Armstrong Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063. The baffle blade shall be in size of 100x50x3600mm in powder coated to Woodgrain finish – Red Oak & Cherry. The baffle blade shall be suspended using Slotted U-profile of 20 x 30mm at on-center spacing 100mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fInstallation of U-Grid: The U profile to be suspended at every 1200mm on-centre using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.75M. 1st U-Grid Channel must be no more than 400mm from the perimeter.ixed with End caps. Installation of Armstrong Baffles: Locate the slot for Baffle Hangers in U Profile section at 1200mm centres. Hangers are inserted into the slot, and then inserted in the provision in the Al baffle. Two baffle hangers are required one on each side of the U-profile to hold the Al baffle in its place. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. End Caps to be located by pushing the End Cap tongues into open Baffle slots. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.
69Providing, Supplying and Installing False Ceiling of SUPERSIL make Aluminium linear 84C Plain Panels with Wooden Finish Powder Coated having Square edge panels, 84 mm wide x 15 mm deep x length up to 5 mtr. With 25mm recess flange formed out of 0.50 mm thick (TCT) aluminium alloy (AA) 8011-H3 fixed on carriers having 28 mm wide at the bottom x 43 mm deep formed out of 0.91mm thick alumnium sheet stove enameled black with protruding ears to hold the panels in a module of 100 mm.and supporting structure painted with Spray Paint.The carrier shall be suspended from slab by 4 mm dial galvanized rod with special height adjustment powder coated clips made out of spring steel at maximum 1.2 to 1.5 mtr. Centre to centre. The 4mm dia galvanized rod shall be fixed to slab by forming one end “J” shape with roll inserts. The edge profile formed out of Aluminium Sheet of the size 18 mm x 20 mm shall be fixed on the perimeter of the walls
70Providing, Supplying and Installing of SUPERSIL make Aluminium U Shape Open Baffle CeilingSquare edge panels of 25 mm wide x 25 mm deep x length up to 4 mtr. with formed out of 0.50 mm thick (TCT) Aluminium alloy (AA) 8011-H3 fixed on carriers of 24 mm wide at the bottom x 42 mm deep formed out of 0.91 mm thick alumnium sheet stove enameled black with protruding ears to hold the panels in a module of 50 mm with 25mm Clear Gap between Two Panels (centre to centre 50mm) with Wooden Powder coating on Visible surface of the Panels and Supporting Structure painted with Black Spray Paint . The carrier shall be suspended from slab by 4 mm dial galvanized rod with special height adjustment powder coated clips made out of spring steel at maximum 1.2 to 1.5 mtr. Centre to centre. The 4mm dia galvanized rod shall be fixed to slab by forming one end “J” shape with roll inserts. Edge Profile shall be L - Shaped, roll formed out of 0.5 mm aluminium strips with Powder Coated in standard colours.
71Supplying Waiting Chair Single Seater Lounge Chairas per detail drawing having Complete Frame in Mild steel fully cushioned with 22mm dia pipe frame of 16g. of Approved make and Architect and Client"s requiremment etc. complete.
72Supplying Tables for Waiting Area as per detailed drawings using duly polished Teakwood FramesWith Glass Top having Size of 450 mm Dia x 450 mm ht. of approved make and requirements of Architect and Client including transporting and fixing in position etc.complete.
73Providing, fabricating and fixingReception table as per detail drawing of following sizes made of BWR grade plywood of 19mm thick conforming to IS 303 to achieve 50mm thick and exposed surfaces shall be finished with 12mm thick Corean(duponal) of approved colour, shade and make , including two nos. storage units of size 450mmx600mmx600mm with three equal drawers made of 19mm thick ply finished with 3.5-4mm thick polished veneer of approved colour, shade and make , including necessary hardware like SS handles , sliding channels, locks , including providing and fixing grommet of approved make, all the surfaces below table shall be finished with 1mm thick laminate of approved colour , make and shade , including necessary arrangements for electrical cables, boxes etc. including all material and labour all complete as per drawings, specifications and direction of Engineer-In-Charge. 3000mm x 750mm x 1050mm H
74ProvidingWAITING AREA WOODEN CABINET as per detail drawing having dimensions 1800*450*2100 mm made up of 19mm think MR Grade ply with 1.0 mm thick laminate finish
75Providing, Transporting and placing/fixing in position rectangularCafeteria SERVICE COUNTER TABLE as per detailed designs/ drawings with 6 MM CORIAN finish backpainted glass finsih of approved shade and patterns of approved make and requirements by Architect and Engineer In-charge etc. complete.
76Providing cafeteria cabinet as per detail drawing having TANDEM DRAWER SYSTEM (6 SMALL DRAWERS, 8 BIG DRAWERS, 1 INNER DRAWER) CUSIO CUTLERY THALI & CUP/SAUCER ATTACHMENT IN SS WASTE BIN SWING MAIN PLATEFORM CORIAN TOP OF 12MMBACK PAINTED GLASS DEDO as approved by Architect and Engineer In-charge including placing and fixing in position etc. complete.
77Providing and Supplying Two Seater Sofa as per detail drawing of min. size 1320 x 530 x 790 mmhaving ERW Profile Frame with PE RattanSolution Dyed Acrylic Fabric of approved make and as per requirement of Client and Architect etc. complete.
78ProvidingCentre Table as per detail drawing of size 900x600x600 mm having ERW Profile Frame with PE RattanSolution Dyed Acrylic Fabric and Top of Toughened Glass of approved make and as per requirement of Client and Architect etc. complete.
79Providing and Supplying Table as per detail drawing of Trio 01 : Square / Round Cafe Table with BSL Top of 25 mm thk & Round finished with PVC Edge banding , Frame in S. Steel of 60mm dia Centre Pipe supported by 4 legs of 45mm T pipes, fitted on M.S. bracket. Sizes:- 750mm diaof approved make and as per requirement of Client and Architect etc. complete.
80Providing and fIxing WOODEN PANNELING ON MIRROR GYM AREA by using 19mm thick ply and 12mm thick glass Classic two tone styling elevated, matte black paired with a modern light wood finish for a contemporary feel.
81Providing & Fixing 3M Controltac opaque printable vinyl with advance repositionability and Comply adhesive for bubble free application as per design approved by E.I.C
82EXTERIOR LED LOGO Supplying & fixing LED Signage for SPORT COMPLEX Building as per approved Designa dn Drawings with following requirements including scaffolding and fixing the signage in place etc.complete.; - Letter will be made from Acrylic Sheet (3.0mm) - Acrylic letter with Aluminium Channel - 3.5 inch embose & will be painted - Backside of Letter will be supported with ACP Sheet - Sign Box will be made from M.S. Structure of 25x25 mm section covered with ACP Sheet (3.0 mm thickness) - Size of ACP Box : 23 ft x 3 ft x 0.5 ft ( W x Ht x depth) - LED will be fixed in Acrylic Letter to illuminate. - Height of Letter for SPORT COMPLEX : 18 inch
83EXTERIOR SIGNAGE Supplying and Fixing Exterior Pylon Tower Signages of size 6.0 feet x 4.0 feet (Make: COSIGN Modular Sign System, Belgium) using H Totem using H-type Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001- 2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. With Lifetime warranty under normal working conditions including required support structure fabricated with MS Steel and fixing in soil with required RCC Foundation as per design, drawings and direction of Engineer In-charge.
84INTERIOR SIGNAGE Supplying and Fixing Wall Mounted Sign of size 105 mm x 420 mm of make (Make: COSIGN Modular Sign System, Belgium - a flexible & contemporary sign system consisting of a series of soft curved profile with straight edge. Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. With Lifetime warranty under normal working conditions APET anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws as per design,drawings and directions of Engiener In-charge etc. complete.
85Providing Connect Table with Side Table and Mobile Pedestal for Gym Area as per detail drawing Size : Main Table 1800 L X 750 W x 750 H mm Size : SideTable 1200 L X 450 W x 750 H mm SYSTEM : CONNECT, Specification : Table top : 25mm thick Pre-laminate particle board with 2mm pvc edge banding on all expossed edges. Under-structure : Supported on MS powdercoated CONNECT leg with supporting beams. Modesty Panel : 18mm thick prelam particle board Modesty panel considered on main side of front table. Wire management : 65Dia grommet. Side / Back Storage : Storages are made of 25mm Thk Table Top, 18mm Thk Openable Shutters with finger groove handle. Mobile Pedestal -PRELAM PEDESTAL 2D+ 1F SIZE : 400L X 450D X 600HT DESCRIPTION : TABLE TOP : Made of 18mm thick Pre-laminated particle board finished with 2mm PVC edge lipping. Back - 9 mm thick pre laminate particle board Edge - All exposed area with 2mm thick PVC EDGE Lipping. Handle - New finger groove handle.2
86Supplying Recepation & GYM Trainer Chair as per detail drawing of Buro 03 - Low Back MD"s Visitor Chair Chairs in Metal frame with High Density PU foam in seat & back, PU arms, Center Tilting Mechanism, Nylon Base, & Gas Lift and Chrome Base as approved by Engineer In Charge ans Architect etc.complete
87Supplying Recepation & GYM Trainer Chair as per detail drawing of Marco 02 : Medium Back Chair in Moulded Ply. PU Foam in Back & Moulded PU Seat. 3D Adjustable Arms with PP Pad . Synchronized ck Mechanism. Chrome Base & Gas Lift. as approved by Engineer In Charge ans Architect etc.complete
88Supplying 8 Door Locker as per detail drawing of size:- 800mm Lx 450 mm D x 1850mm Ht as per requirement and approval of Client and Architect etc. complete
89ProvidingBack Storage 2800 & 2600as per detail drawing SIZE - 2700 L X 450 D X 750HT mm PRODUCT - STORAGE Table Top: 18mm Thk pre laminated particle board Back: 9mm Thk pre laminated particle board with 2mm PVC edge lipping Shutters: 18mm Thk pre laminated particle board Edge: All exposed area with 2mm thick PVC edge lipping Handle: New finger groove handle Lock: Regular lock
90Supplying wooden Benchs for Locker room as per detail drawing of size 1800mm x 450mm of approved make and requirement of Client and Architect etc. complete.
91ProvidingWooden model:JSA -NAW-MD3150IHSauna (Dimension:1500x 1100 x 2100) having features K3 Control Panel,LED light color therapy,bluetooth music system,hemlock wood,Aromatic oil container having capacity of 3 persons with comfortable seatingHeater info: 6 Pcs,2000w
92Providing Raucord Outer Furniture for swimming pool including 6 nos of lounger seat, 2 nos of sofa swing,8 nos of two seater sofa with 4 nos of center table and 6nos ofchair set with center table and umbrella having features 100% UV Protection,Made from collection of high qualtiy premuim synthetic weaving material, Fade and scratch ressistant, Stain ressistant and colorfast Outdoor Resilience,Wipe-Clean Surface Strong and Durable wihout compromising on shape and foam, Waterproof and temperature ressistant and placing/fixing in the position etc. complete.
93Providing Glass Enclosurefor steam room having dimensions (2600 X 2970 MM, H -2200MM) with features10 MM Toughened Glass ( CLEAR ) Glass To Glass Hinges - 2 Nos CHROM (Inside /outside Opening) Towel Rod On Door(JAQUAR MAKE) 700 MM Door Opening Inside / Outside 1300 MM Fixed Glass + 1300 MM Fixed Glass APPROX 1135 MM Fixed Glass +1135 MM Fixed Glass APPROX Magnetic beeding and Air Gasket 2 Nos Each Wall Brackets CHROM for Both the Walls(JAQUAR MAKE) 2 nos. corner brackets 4 Nos Floor / 4 Ceiling Brackets CHROM (JAQUAR MAKE) ANTI LIME SCALE TREATED GLASS
94Providing & fixing of Heavy Duty Badminton postin aluminium and steel uprights option with built in weights & floor protection pad fitted with base, uprights and back support can be detached, including wheels for easy movement complet in all respects.
95Providing & fixing Cosco Badminton Net 20 feet x 2.5 feet size, with tape all round Ideal for training & competitive matches, theseRegulation Badminton Nets combine an elite performance with supreme durability.Expertly manufactured using a combination of braided nylon netting with a PVC coated fabric headband
96Providing and erecting Turbo Vent of 600mm dia with SVS (Sudha Ventilation System) and stainless steel top plateAluminum Alloy rivets with Washer having Centre shaft 18mm high carbon steel zinc plate.Twin Sealed bearings with self lubricating Polyamide to ensure frictionless rotation even at lowest wind velocity
97LANDSCAPE WORKS: Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C)By mechanical means in area of light jungle
98Excavation for foundation upto 1.5 m depth including sortingoutandstacking of useful materials anddisposing off the excavated stuff (B)Dense or Hard soil
99Brick work using common burnt clay building bricks having crushing strength not less than 35kg/Sqcm. in foundation and plinth. In cement mortar 1:5 (1 cement : 5 fine sand) (B) Conventional
10020mm thick sand faced cement plaster on walls upto height 10metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
101Providing and laying cementconcrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth(Make specified as per appendix-1)
102Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
103Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.
104Filling in plinth with sand under floors including watering ramming, consolidating and dressingcomplete (upto 10 ton)
105Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. WMM 1st Layer & 2nd Layer as per MORTH Clause : 406
106Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,& having CBR 30% minimum, complete as per clause 401
107Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick
108Providing and laying Riverwash/natural finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry andpointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineering- Charge : Flamed finish granite stone slab Jet Black or equivalent.
109Providing and layingMandana stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry andpointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineering- Charge : Colour Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
110Providing and fixing pre-cast Rubber Dye inter locking concrete block 60mm thick with grade of concrete M250 pnumatic compressed by mechanically pressed and as per approved design including 75mm Sand layer for levelling and filling the joint with sand in proper line and level etc complete.
111Main Entrance Sclupture Main Entrance, 10" length, 4" height, 6mm gauge MS structure with powder coating (with installation)
112P/F of Wooden Pergola as per Design & Drawing complete in all respects alround the swimming pool. Pergola - POSTS of 85mm x 85mm x 3000mm, Tie Beams=140mm x 42mm x 3900mm / 4800mm / 5100mm and louversof 42mm x42mm / 11mm x 26mm
113HORTICULTURE WORKS: Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
114Supplying stacking and spreading of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment).
115Carting of soil from inside plant area, including to loading , unloading and transport
116Supplying , stacking and spreading of river sand at site includingtransportation to site . A source sample of sand, prior to stacking at site shall be got approved, the quantity of the same can be verified by volume as well as weight or density etc. soil filling up to as required.
117Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource approved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site.
118Mixing earth and manure or in proportion specified or directed, Spreading ofdung manure or / and good earth in required thickness.and fine dressing the ground as per natural gradiant
119Lawn planation Selection-1: In rows 1 to 2 cm apart in either directionincluding watering, fertilizing and maintenance of the lawn for2 months or more till the grass form a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately) . Maintaining the grassfor the period of two months in a presentable condition involving all the operations of de-weeding , application of chemical fertilizer, watering, mowing ,rolling etc.
120Planting saplings of plants/ trees in the proper beds as prepared, and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixedwith manure orin the ratio of 2 : 1 by volumethe excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes1.2 m dia and 1.2 m deep Big Trees (The height of plant shall be considered as 8"-10’ and girth size 60mm-80mm). Albizia lebbek, Melea azedirach, Acacia auriculiformis, Dalbergia Sissoo, Emblica officinalis, Dalbergia Sissoo, Emblica officinalis, Azadirachta Indica, Bauhinia variegata, Pongamia pinnata, Butea monosperma, Bauhinia variegata, Cassia fistula, Erythrina indica, Terminalia bellirica, Terminalia arjuna, Commiphora caudata, Albizia saman, Bauhinia x blakeanea, Milingtonia hortensis, Roystonea regia, Caryota urens, Lagerstroemia speciosa, Tamarindus indica, Gliricidia sepium, Colviller racemosa, Alstonia scholaris, Delonix regina, Stercullia foetida, Klgellia pinnata, Senna siamea, Borassus flabellifer, Phoenix sylvestris, Tabebuia rosea, Hyphaene dichotoma, Holoptelea integrifolia, Spathodea companulata, Millingtonia hortensis, Alianthus excelsa, Bombax ceiba, Livistonia chinensis, Washingtonia robusta.
121Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixedwith manure orin the ratio of 2 : 1 by volumethe excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes0.15 m dia and 0.15 m deep. Shrubs approx 109580 nos. and 2"-3" height and girth size8mm-12mm: Calotropis procera, Jatropha integerrima, Thevetia peruviana, Turnera ulmifolia, Stachytarpheta indica, Pseuderanthemum reticulatum, Senna alata, Pennisetum setaceum, Pennisetum setaceum rubrum, Cymbopogon citratus, Chrysopogon zizanioides, Saccharum munja, Carrisa congesta, Ruellia tuberosa, Barleria cristata, Bambusatuldoides, Ixora singaporensis, Hamelia patens, Nerium oleander, Euphorbia milli, Leucophyllum frutescens, Ixora brachiata, Pandanus odoratissimus, Stachytarpheta jamaicensis, Calliandra haematocephala, Tabernaemontana "Dwarf", Quisqualis Indica, Cliloria ternatea, Allamanda cathartica, Russelia quisetiformis, Schefflera arboricola, Acalypha hispida, Tecoma smithii, Malvaviscus penduliflorus, Pandanus baptistii
122Planting saplings of ground coversin the proper beds as prepared, and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixedwith manure orin the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes1.2 m dia and 1.2 m deep Ground Covers approx 246555 nos. and min. 6" height and girth size 5mm-8mm: Wedelia trilobata, Asparagus sperengeri, Jacquemontia violacea, Senecio orange, Asystasia gangetica, Ficus repens, Setcresea purpurea, Tradescantia spathacea
123Supply, checking, storing and fixing in position European water closet comprising of Wall hung European W.C. Pan Model ARIA-ARS-WHT-3995 or Equivalent in white colour, on approved type of chairs,Concealed flushing cistern Model No.Geberit Omega Concealed Cistern with Flush plate or Equivalent or Equivalent as directed,C.P health faucetModel No. JAQUAR-ALD-CHR-573GD or Equivalent with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks Model No.JAQUAR-OPP-CHR-15053PMor Equivalent for flushing cistern,C.P. brass 2-way bib cock Model No. JAQUAR-OPP-CHR-15041PMGD or Equivalent,CP Toilet paper holder Model JAQUAR-ACN-CHR-1153S or Equivalent,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with brackets and accessories in position,Necessary pipe connection to PVC / PP / CI soilpipe,Painting bracket with two coats of white enamel paint over a coat of primer.
124Supply, checking, storing and fixing Under Counter wash hand basin Model No. JAQUAR-FNS-WHT-40701 or Equivalent with ,32 mm heavy plated C.P. waste coupling fitting Model No. JAQUAR-ALD-CHR-705 or Equivalent withpop-up,32 mm heavy plated C.P. bottle trap Model No.JAQUAR-ALD-CHR-769L300*190 or Equivalent with cleaning eye with extension piece and wall flange,Painting brackets with two coats of white enamel paint over one coat of primer,CP Basin Faucet Model No.JAQUAR-SNRCHR-51011GE or Equivalentwith 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure.
125Supply, Checking, Storing and fixing vitreous Large flat back urinalsModel No. JAQUAR-URS-WHT-132530 or Equivalent with Conceal automatic fushing system Model No. JAQUAR-SNR-CHR-51097G or Equivalent in white colour with concealed type wall hanger or special bracket in wall and hinged typeC.P. dome gratings.C.P. flush pipes from auto flush, spreaders, full bore inlet caps as necessary made to measure.C.P. waste pipe and Speader under each urinal pan,leading to the CP bottle trap Model No.JAQUAR-ALD-CHR-769L300*190 or Equivalent below and painting with two coats ofwhite enamel paints and cutting and making good the walls wherever require.
126Supply, checking, storing & fixing Over head shower 100 mm dia with Shower Arm Model No. JAQUAR-OHS-CHR-1989GA or Equivalent complete as per instructions of the engineer-in-charge.
127Supply, checking, storing & fixing CP single lever wall mixer Model No. JAQUAR-OPP-CHR-15065KPM or Equivalentwith Concealedbody Shower Valve Model No.JAQUAR-ALD-CHR-065 or Equivalent complete as per instructions of the engineer-in-charge.
128Supply, checking, storing & fixing CP bath spout without Diverter Model JAQUAR-SPJ-CHR-15429PMGD or Equivalent complete as per instructions of the engineer-in-charge.
129Supply, checking, storing & fixing C.P. brass 600mm lengthtowel bar Model No. JAQUAR-ACN-CHR-1111SM or Equivalent with CP brass Screws complete as per instructions of the engineer-in-charge
130Supply, checking, storing & fixing C.P.brass towel ring Round Model No. JAQUAR-ACN-CHR-1121Bn or Equivalent to PVC cleats with C.P.brass screws includingcutting and making good the walls wherever required .
131Supply, checking, storing & fixing CP Soap dish JAQUAR-ACN-CHR-1131N or Equivalent complete as per instructions of the engineer-in-charge.
132Supply, checking, storing & fixing manual CP soap dispenser Model No.JAQUAR-ACN-CHR-1135N or Equivalent withliquid soap (including one time soap fill) includingcutting and making good the walls, wherever required complete as per instructions of the engineer-in-charge.
133Supply, checking, storing & fixing C.P. brass angle valve for basin & Sink Model No. JAQUAR-CON-CHR-053KN or Equivalent of approved quality conforming to IS:8931 for a) 15mm Nominal Bore
134Supply, checking, storing & fixing C.P. brass bib cock Model No Jaquar-FUS-CHR-29037 or Equivalent of approved quality conforming to IS:8931. a) 15mm Nominal Bore
135Supply,checking, storing & fixing straight/offset type Macfit single body push fit type WC Pan Connector Jaquar-ZPS-WHT-VB01 or Equivalent with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet)
136Supply, checking, storing & fixing of Heavy class S.S. Grating Model No. Chilly-CCT-SFC-127or Equivalent with Mosquito /Cockroach proof S.S.strainer of approved designby Interiror including setting in floor with cement motor to match with floor finish as per architect requirement suitable for FD (Floor drain) and FT (Floor trap). Note : Size of trap is vary as per final Product Selection.(Including Shaft floor Drain & Fire Escape Balcony )
137Receiving, checking, storing & fixing Stainless Steel Body Auto hand drier Model No . Jaquar-HDR-SAP-M99ACSto beoperatedwith 220 volts,singlephase,with fully hygienic condition, with all accessories including cutting and making good the walls, wherever required complete as per instructions of the engineer-in-charge.
138Installation testing and commissioning self contained pressure type water coolers suitable for operation on 230 voltage - 10% single phase AC supply and generally confirming to the requirements of IS :1476/78 having following nominal cooling capacity at an ambient temperature of 30 deg.c and drinking water inlet temperature of 35 deg c and drinking water outlet temperature of 13.5 deg. complete with compressor over head protector, thermostat and steel tank. 40 Ltr. Cooling and 80 Ltr Storage.Cap.(Make:Voltas,Blue Star,Usha)
139Drinking Water RO - Providing & fixing Wall Mounted RO plant with UV Technology I.S.I marked,C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection. Flow-2 LPM(Make:Aquaguard,Eureka Forbes,Kent)
140SOIL WASTE AND VENT PIPE: Providing and fixing PVCAgri 6Kg/cm2 and fitting for SOIL &WASTE waterdischarge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance,cutting, chases/holes in walls/flors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 50 mm
141Providing and fixing PVC SWRPipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL &WASTE waterdischarge, including all fittings with andwith out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 75 mm
142Providing and fixing PVC SWRPipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL &WASTE waterdischarge, including all fittings with andwith out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 110 mm
143Providing and fixing PVC SWRPipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL &WASTE waterdischarge, including all fittings with andwith out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (For soil , waste , Rain , Vent for Shaft /External Area Downtake)(Make:Astral,Ashirvad,Suprime) 150mm Dia.
144Providing and fixing PVCtrapsofself cleansingdesignwithwater seal not less than 50mm withorwithoutvent, includingsettingthe trap in 1:2:4 cement concrete etc. complete. The trapshallbe`P"type asrequired. Trap with100 mminletand outlet 75mm/100mm dia.(Make:Astral,Ashirvad,Finolex)
145Providing and fixing in position Multi Floor Trap/Plain Floor Trap self cleansing design moulded or fabricated with 50 mm water seal conforming toIS:14735-90 includingsettingthe trap in 1:2:4 cement con"crete etc.(Make:Astral,Ashirvad,Finolex) 100mm Outlet
146Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating)complete as required.(Make:Neer,Weimer) 300x 300 mm (75mm outlet pipe dia )
147450x 450 mm (100mm outlet pipe dia )
148450x 450 mm (150mm outlet pipe dia )
149Providing and fixing S.W. gully trap with Each C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 1 OOmm size P or R Type
150INTERNAL WATER SUPPLY :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 15 mm nominal outer dia Pipes ( SDR 11 )
151Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 20 mm nominal outer dia Pipes ( SDR 11 )
152Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 25 mm nominal outer dia Pipes ( SDR 11 )
153Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 32 mm nominal outer dia Pipes ( SDR 11 )
154Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 40 mm nominal outer dia Pipes ( SDR 11 )
155Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 50 mm nominal outer dia Pipes ( SDR 11 )
156Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC high bonded solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(The pipe length inserted in the fitting shall not be measured for payment) For Cold Water Lines (Inside Shaft & Terrace & Riser)(Make:Astral,Ahirvad,Finolex) 65 mm nominal outer dia Pipes ( SCH 80 )
157Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 20 mm dia
158Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 25mm dia
159Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 32mm dia
160Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 50mm dia
161Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.(Make:Sant,Zoloto,leader) BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 80 mm dia.
162Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.(Make:Sant,Zoloto,leader) BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 65 mm dia.
163Providing and fixing Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for cold / hot water circulation including insulation as specified.(Make:Sant,Zoloto,leader) 80 mm dia.
164EXTERNAL WATER SUPPLY:- Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore
165Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 (Make:Sant,Zoloto,leader) 80 mm dia
166Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. (For Gardan Hydrant System)(Make:Astral,Ahirvad,Finolex) 25 mm outer dia
16732 mm outer dia
16840 mm outer dia
169Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (For Gardan Hydrant System)(Make:Sant,Zoloto,leader) 25 mm dia
170EXTERNAL SEWERAGE & STROM DRAINAGE Providing, laying, jointing and testing heavy qualityDWC (Double wall Corrugated ) under ground application pipes for Sewer and strom linewith Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. (Make:Astral,Ahirvad,Suprime) 150 mm dia
171Providing, laying, jointing and testing heavy qualityDWC (Double wall Corrugated ) under ground application pipes for Sewer and strom linewith Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. (Make:Astral,Ahirvad,Suprime) 200 mm dia
172Providing, laying, jointing and testing heavy qualityDWC (Double wall Corrugated ) under ground application pipes for Sewer and strom linewith Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. (Make:Astral,Ahirvad,Suprime) 250 mm dia
173Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design a)150 mm dia
174Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design b)200 mm dia
175Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design c)250mm dia
176Providing laying (to level or slopes) and jointing reinforced concrete Light duty non pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(E) 450mm (uoto 10 ton)
177Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 800mm and 0.9M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A)With 230mm thick walls of brickmsonry using brick having crushingstrengthnot lessthan 35Kg./Sq.cm. in CementMortar 1:5(1- Cement: 5-Coarse sand) (1) Atypedepth0.90Metrefor 150mm diameter sewer.
178Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A)With 230mm thick walls of brickmsonry using brick having crushingstrengthnotlessthan 35Kg. /Sq.cm. in Cement Mortar 1:5 (1-Cement:5-Coarse sand) (2) Btypedepth1.50Metrefor 150mm diameter sewer.
179(I) Extraratefor constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over itemNo.24.27 (I) for depth from 0.9M to 1.5M.
180(II) Extra rate for constructing B.B.masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
181Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. complete.
182Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (more than 10 ton)
183Constructing brick masonry road gully chamber 1100mm x 775mm including 500mm x 450mm (C.I. horizontal grating with frame and vertical grating complete.) (more than 10 ton)
184Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions455mmx 610mm and 450mm deep for single pipe line. (more than 10 ton)
185Extra over items 24.44 for every additional depth of 0.1 M. of part thereof beyond 450mm depth for Brick masonry chamber.(ii) for 455mm x 610mm size.
186Supply , Installation , testing and commisioningof FRP (Fiberglass Reinforced Polymer) Manhole cover with frame design as per EN 124 Standard CLass Load in removable sections with matching frames ofMS angles or making a similar size of offset in floor trimix / concrete, over open channel / chamber as per the drawings and designs and approved by architect and testing of joints complete as per direction of Engineer in Charge. (Basment & ground Civil drain line ).(Make:Everlast,Tharmodrain,HP) 600mm Dia Square Cover Over Head tank (500kg Load )
187Rain Water Harvesting system : Construction of rain water harvesting size 2 m dia x 3.5m effectivedepth for the re-charging of storm water run off including the civil work with following specification [Construction of Chamber]. De-Silting Chamber: Providing and constructing masonry de-silting chamber 1800mm x 1500mm with required depth inside with 75 class designated brick work in cementmortar 1:6 (1cement : 6 fine sand) with C.I double seal medium duty 560mm dia manhole cover (2Nos.). top slab 1:2:4 mix (1cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement, foundation concrete 1:5:10 (1cement : 5 fine sand:10 grade stone aggregate 20mm nominal size including baffle wall, necessary excavation, back filling and disposal of surface earth. Complete with inlet, outlet and overflow arrangement. Foot rest @400mm c/c, grating of required size with 16mm sq.bars and frame @20mm clear spacing fixed at month of pipe as per site conditions and direction of Engineer in charge Drilling: Drilling percolation borehole 200mm dia with reverse rotary method in all types of soil up to 50 m (approx.) depth including cost for mobilization of rig and making goodthe area upon completion of work. Contractor shall arrange for all necessary tools, water and consumable and laying for drilling. Providing and laying pea gravel all aroundthe casing pipe. 160 mm dia slotted UPVC pipe of 6 Kg/cm2 - 35 m -40m or as per site sub-strata or set as per direction of Engineer- in charge 160 mm dia UPVC blind pipe of 6 Kg/cm2. - 35 m -40m or as per site sub-strata or set as per direction of Engineer- in charge Rain Water Harvesting Well Filtration Chamber: Providing and constructing rain water harvesting well/filtration chamber of size 2 m dia x 3.5 m eff. depth inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including 300mm duty. Boulder 10-20mm, 300mm duty, gravel 5-10mm size, 300mm depth coarse sand 1.5-2.0mm including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm dia deep holes @500mmc/c to be provided 1200 c/c above the bottom of wall, 100mm C.I vent pipe -2m height with cowls. Rate shall include excavation, back filling and all other operations necessary for completing the job.
188Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metredepth below ground level. All type of soil 300 mm dia metre
189Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
190HYDROPNEUMATIC SYSTEM AND VARIOUS PUMPS Variable Speed Hydro-booster System for domestic water supply : Compact self contained Hydro-booster system comprising of following : In-line, vertical multistage, centrifugal clear water pumps with SS-316L /304 casing, S.S 3I6L impeller and SS-304/316 shaft, SS-316L/C.I. Base CED coating & head TEFC IE4/IE3 magnetic motor with mechanical seal with Company fitted with company compliance certificate. Vendor to submit performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.Panel mounted PLC and HMI Based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a Panel/Inbuilt with pump motor with IP54 class with pressure sensor transmitter (each pump each VFD), diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. All alarms should be displayed in the controller. System should be equipped with dry running protection by both, reputed make Float (NO/NC) having 20 Mtrs Submersible Cable installed in the Tank & 0-10V DC Device installed on Suction Header. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Global / Equivalent Make Pre-charged diaphragm pressure vessel with 3 years warranty from manufacturing date and company tested replaceable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be following capacity or as per manufacturer recommendation). Vessel Shall be pre-charged with Nitrogen as per respective Pump Head. Each Vessel shall be installed with 2 1/2" SS 304 Glycerine Filled Manometer on Top.Set of accessories such as SS 304 / MS with CED Coated headers for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power and control cabling etc. complete. For supplying DWS to all Floor (Terrace Booster Pump) Capacity per pump -250 LPM Head-20 mtr Pressure vessel - 100 liters or as per manufacturer recommendation Approx. Elec. Load. -2.0 KW each pump Location - Terrace level 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation) Suction head-flooded positive suction Supply, Installation, testing & commissioning (Make:Kriloskar,Lubi)
191Supply, installation, testing & commissioning of Submersible single stage single entry pumps connected to submersible motor (The motor shall be IE3 watertight according to IEC class IP 68, and incorporate class F, insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit Or Auto Coupling with rubber diaphragm and bend, vertical discharge pipe,with Starter PanelIP 54 Outdoor Type ,The pump shall be provided with a lifting devise of pull chain/guide rail & G.I. heavy class rising main of 5m length including interconnecting piping, valves (Ball Valve / Butterfly), Non return valves (GM/CI) 15 m cable etc.High level and low level sensor with motorized butterfly valve as per requirement complete in all respects. (Pumps shall be installed in a set of two pumps One working and One standby, with cascade operation). For supplying Domestic Water up to terrace Capacity per pump -200 LPM Head-30 mtr 1 Set (With Single VFD) = 2 Nos. Pump (1 Working + 1 Standby - cascade operation) Suction head-flooded positive suction Supply, Installation, testing & commissioning (Make:Kriloskar,Lubi)
192Supply, installation, testing & commissioning of Submersible Multi stageborewell pumps (Sutable for 150mm dia )connected to submersible motor (The motor shall be IE3 watertight according to IEC class IP 68, and incorporate class F, insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit Or Auto Coupling with rubber diaphragm and bend, vertical discharge pipe,Control Panel,Cable,Column pipe etc complete to the entire satisfaction of the Engineer-in-charge.(Make:Kriloskar,Lubi) Flow-30000 Ltr/Hr Head-50m
193Supply, Installation, Testing and Commissioning of Electrically Operated Heat Pump. Each element is provided with an independent control thermostate (adjustable: 43 - 77 °C) Tank Storage Capacity - 450 Liters Maximum Temperature - 77°C Working Pressure - 10 Bar Power Supply - 240 Vac (-15/+10%)/50 Hz (+/-1Hz) (1w +1s)
194Supply,Installation, Testing and Commissioning of Stainless Steel (SS304)Model:JSG-WHT-NMID90 Automatic Steam generator having features Auto Drain,Auto power off and water inlet,Heating Element of SS316, over heat Protection system,Pressure Safety Valve,water processor with control panel JSG-WHT-CPSQUARE and necessary fittings,power cable etc complete.
195SWIMMING POOL :- FILTERATION SYSTEM WORK Supply, installation, testing and commissioning of Vertical bobbin wound sand filer manufaccturedwithfilber glass and polyester resin, totally anticorrosive fitted with collector arms & diffuser made in UPVC and polypropylene,resistant to salted water.Filter will be supplied with nozzle plate, sight glass, manhole, pressure gauge. Working Pressure. 2.5kg/cm2-4kg/cm2,maximum tempreture:50 degree C, supplied with frontal piping, manometer,pipe supports and sand media complete in accordance to the manufacturers specifications. Diameter: 1200mm, Filtration Velocity: 35m/hr, Flow Rate: 36 m3/hr (each), total flow rate will be mentioned above as per design,Make: Haywards, MagnaPool,W18 Tech
196Supply,installation,testingandcommissioningof Centrifugal Horizontal Back-pull-out industrial type pump set with cast iron body,bronzeimpeller,carbon-ceramicmechanicalseal, stainless steel shaft, with TEFC 1450 RPM prime mover suitable for 415V, 50Hz, 3 phase AC power supply, with base-plate, coupling, guard, stainless steel pre-filter with stainless steel basket, NRV, foot valve, isolation valve and pressure gauge in accordance with technical specification. (2 working + 1 standby) Flow rate: 40m3/hr@18m. Make: Kirloskar, Grundfos,Haywards, MagnaPool.
197Supply, Installation, Testing and Commissioning of Chlorine Dosing System consisting of one chemical grade tank with an electronic positive displacement diaphragm dosing/ metering pumpwithallaccessorieslikeinjectionfittings,tubingand suction filter etc.The dosing pump liquid ends will be in PVDF. Suction&dischargetubingshouldbePE.Thedosingpump should be capable to run on pulse from a external device and also have a auto / manual switch. All four valves should have a double ceramic type NRV system. The dosing pump shall also be equippedwith a degassingvalve.Make:Grundfos, Prominent, Milton Roy. Capacity: 0-20 LPH @4 bar with 200 L Tank
198Supply, Installation, Testing and Commissioning of Acid Dosing System consisting of one chemical grade tank with an electronic positive displacement diaphragm dosing/ metering pump with all accessories like injection fittings, tubing and suction filter etc. ThedosingpumpliquidendswillbeinPVDF.Suction& discharge tubing should be PE. The dosing pump should be capable to run on pulse from a external device and also have a auto / manual switch. All four valves should have a double ceramic type NRV system. The dosing pump shall also be equippedwith a degassingvalve.Make:Grundfos, Prominent, Milton Roy.Capacity: 0-10 LPH @4 bar with 200 L Tank
199Supply, Installation, Testing and Commissioning of Alum Dosing System consisting of one chemical grade tank with an electronic positive displacement diaphragm dosing/ metering pump with all accessories like injection fittings, tubing and suction filter etc. ThedosingpumpliquidendswillbeinPVDF.Suction& discharge tubing should be PE. The dosing pump should be capable to run on pulse from a external device and also have a auto / manual switch. All four valves should have a double ceramic type NRV system. The dosing pump shall also be equippedwith a degassingvalve.Make:Grundfos, Prominent, Milton Roy.Capacity: 0-10 LPH @4 bar with 200 L Tank
200Supply, Installation, Testing and Commissioning of Soda Ash Dosing System consisting of one chemical grade tank with an electronic positive displacement diaphragm dosing/ metering pumpwithallaccessorieslikeinjectionfittings,tubingand suction filter etc.The dosing pump liquid ends will be in PVDF. Suction&dischargetubingshouldbePE.Thedosingpump should be capable to run on pulse from a external device and also have a auto / manual switch. All four valves should have a double ceramic type NRV system. The dosing pump shall also be equippedwith a degassingvalve.Make:Grundfos, Prominent, Milton Roy.Capacity: 0-10 LPH @4 bar with 200 L Tank
201Supply of TCCA
202Supply of Acid
203Supply of Alum
204Supply of Soda Ash
205Supply,Installation,TestingandCommissioningofOzonator with venturimeter and Other Accessories, Ozonator MF8 Oxygen Feed, Corona DischargeType, SS 316 Jacketed Water Cooler with 10 Cells, With Ozone Indicator and Rotameter, 1 KW Power and 5 A Supply Fuse. Capacity: 60Gm/hr,Make:Aquazone, W18 Tech,,Haywards, MagnaPool.
206Supply, Installation, Testing and Commissioning ofoxygen concentratorwithoxygenflowof 10LPM. Make:Nuvo USA.
207Supply,Installation,TestingandCommissioning ofBooster pump with control panel, Make: Lubi, Kirloskar etc.
208Supply,Installation,TestingandCommissioning Floor/Wall Inlets, made of ABS white plastics, 50mm glue connection. Flow Rate: 4 m3/hr Make: Aqualux - France, Certikin, Pentair, Aqua, Haywards, MagnaPool,Atecpool
209Supply, Installation, Testing and Commissioning Drain Grill, Rectangular,MadeofSS304,Size500mmx500mm Make: Haywards, MagnaPool,W18 Tech.
210Supply, Installation, Testing and CommissioningProviding and Fixing of Modular type overflow gratings, White colour made of polypropylene (PP), 33 units= 1 meter, as per specification Size: 300mm. Make: Haywards, MagnaPool,W18 Tech.
211Supply,Installation,TestingandCommissioningofStandard Type Ladder in SS 304 as MOC, 4 step. Make:Haywards, MagnaPool,W18 Tech.
212Supply, Installation, Testing andCommissioning ofSuction Sweeper/vaccumme Head, fixed with clip type connection of 1- 1/2". Size: 600mm.Make: Haywards, MagnaPool,W18 Tech.
213Supply, Installation,Testing and Commissioningof Reinforced Telescopic Handle, Pool Cleaning. Size: 9m. Make: Haywards, MagnaPool,W18 Tech.
214Supply, Installation, Testing and Commissioning of Floating Suction / Hose Pipe, made of polyethlyne in blue colour, connection :40mm, 30m LongMake:Haywards, MagnaPool,W18 Tech.
215Supply, Installation, Testing and Commissioning of Deep bag skimmer/Net, 40mm Clip type connection.Make: Haywards, MagnaPool,W18 Tech.
216Supply, Installation, Testing and Commissioning of Algae Brush with SS Bristle, 40mmClip typeconnection Make: Haywards, MagnaPool,W18 Tech.
217Supply,Installation,TestingandCommissioning ofStraight brush,40mmCliptypeconnection. Make: Haywards, MagnaPool,W18 Tech.
218Supply, Installation, Testing and Commissioning of Test Kit for measuring Chlorine & pH Levels in pool water .Make: Haywards, MagnaPool,W18 Tech.
219Supply, Installation, Testing and Commissioning of Water Surface Skimmer, clip type. Make: Haywards, MagnaPool,W18 Tech.
220Supply, Installation, Testing and Commissioning ofCurved brush, clip type. MakeHaywards, MagnaPool,W18 Tech.
221Supply, Installation, Testing and Commissioning of Trolley Mounted Cleaning System with bag Filter with a capacity, Pump withPreFilterwithallelectricalconnecitonlikestarterfor on/off along with necessary piping and 50 m cable length. Suppliedwith necessarycontrolvalvesand NRVs with ss nut bolts and washers, flanges etc. for pool cleaning. Make: W18 Tech
222Supply, Installation, Testing and Commissioning PVC Pipe, PN10 confirming to IS: 4985 class IV 10 kg/cm2 including all fittings such as bands, elbows, reducer, tees, union, coupler, tail piece, flanges etc. cost shall be providing supports as per specification and making goods. Pipes shall be connected to pumps, equiments, valves etc to tail piece 50mm,110mm,160mm,200mm.
223Supply, installation, testing and commissioning of sluice Valve of 6" with extended spindle accordance with technical specifications. Make: Mayur, Kirloskar, Trishul
224Design, Manufature, Supply, Installation, Testing and CommissioningofIntegrated,Cubicaltypedeadfront extensional, 16 SWG CRCA sheet steel control panel to the foundation. The Control panle should be suitable for 440 volts, 50 hz 4 wore supply for Recirculation Pumpset, Dosing Pump, Ozonation Systems.Make: W18 Tech
225WATER TREATMENT: Providing, fixing, testing and commissioning of vertical self supporting Multi Grade Filter , in MSRL With Food Grade Antiorrosive paint Outside of vessels, pressure gauges at inlet & outlet, sample cock, air vent valve with piping, Industrial C-PVC, SDR 11.0 grade face piping upto 50mm and aobve 50mm SCH 80 distribution pipe with diffuser on top, CI butterfly valves Multiport valve and all accessories, with initial charge of filter media for Multi Grade Filter, complete. (Contractor has the responsibility to check the quality of water from actual water analysis report before procuring the equipments) Multi Grade Filter : Capacity-1.00 m3/hour Filter dia (approx.)-600 mm Working pressure - 3.0 Kg/Sq.cm Test pressure- 10.0 Kg/Sq.cm Supply ,Installation, testing & commissioning`
226Providing , fixing, testing and commissioning of water softener in MSRL With Food Grade Antiorrosive paint Outside of vessels (shell & thick dished ends) complete with initial charge of resins, Industrial C-PVC SDR 11.0 grade face piping upto 50mm and aobve 50mm SCH 80, CI butterfly valves, pressure gauge, hydraulic brine injector, accessories, including suitable PVC/HDPE 1000ltr brine tank of 2 regeneration capacity complete with resins of approved quality and make. (Contractor has the responsibility to check the quality of water from actual water analysis report before procuring the equipments) Hardness Inlet- 500 PPM (If hardness will vary than the softener design will also vary.) Outlet- <50 PPM Capacity - 1.0 m3/hour OBR- 50 m3 Operating pressure- 3.0 kg/Sq.cm Test pressure- 10.0 Kg/Sq.cm Suggested Resin Quantity-650 Liters Aprox Supply ,Installation, testing & commissioning
227In-line, vertical multistage, centrifugal clear water pumps, speed up to 2900 rpm, with SS-304 casing, SS304L impeller and SS-304 shaft, SS/C.I. Base CED coating & head, connected to a IEC TS 60034-30-2:2016 Standard Motor Class efficiency IE3 with mechanical seal with suitable for 400 / 440 volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation valve, vibration eliminating pads as required, M.S fabricated base plate bolted to cement concrete foundations complete. Company fitted with company compliance certificate. Vendor to submit performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.Electrical Starter panels complete with O/L Relay with Single phasing preventer feature, earth leakage relay, ON-OFF and Trip Indicating lamps, contactors Potential free contacts for Building Automation System, interlocking, level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level, cascade operation, working / standby selection, etc. suitablefor the motor H.P. as specified below. System should be equipped with dry running protection by both, reputed make Float (NO/NC) having 20 Mtrs Submersible Cable installed in the Tank & 0-10V DC Device installed on Suction Header. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors.Set of accessories such as SS 304 headers / MS CED Coated for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power and control cabling etc. complete. Water Treatment Feed pumps - P1 For feeding raw water to water treatment plant and store in soft / treated domestic water tank Capacity per pump -1.0 m3/hour Head -35.0 m 1 Set = 2 Nos. pump (1 working+1 standby), cascade operation Supply , Installation, testing & commissioning
228HVAC: Supply of VRF Airconditioning Units Microprocessor based Outdoor units shall be provided with twin rotary/scroll compressor. It shall be equipped with inverter controller and capable of changing the rotating speed to follow variations in cooling. Outdoor units shallbe suitable for mix-match connection of all type of indoor units. Indoor & Outdoor unit shall be factory assembled, tested and filled with first charge of refrigerant before delivery at site. All compressors shall be of 100% inverter type. Outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels with powder coated finish. All outdoor units above 6 HP rating or in case of with multiple compressors shall be with 3D scroll compressors. The noise level shall not be more than 60 dB A at 1 m distance horizontally and 1.5 m above ground level. All necessary safety devices like high pressure switch, low pressure switch, fuse, crankcase heater, fusible plug, over current protection for Inverter, short cycling guard timer, single phase preventer, Anti Harmonic Filter etc.,. Refrigerant pipe circuit shall include refnets, liquid receiver / accumulator, liquid & gas shut off valves and solenoid valve. Refrigerant pipe shall be in high grade copper (16G) of refrigeration quality with Eddy current testing & material test certificates. All connections like tees, reducers etc shall be standard make fittings. Cold lines shall be insulated to avoid the condensation. For individual piping 50 / 100 mm wide Al tape shall be used at joints of piping with Bands for identification. For Outdoor piping, the finish shall be woven GRP Mat finished with colored Epoxy paints and enclosed with GI trays to avoid physical damage.All Indoor units shall have electronic expansion valve, adequate insulation to avoid condensation. Coils shall be anti-corrosive. Control wiring between Indoor & Outdoor shall be part of VRF supplier scope. Outdoor must be equiped with multi compressor & should be run on failure of any of one compressor. To have provision for potential free contact-to get signal from BMS in case of fire -so that AC can get shut off. All accessories for installation / commissioning should be part of the package ( VRF Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 20 HP
229Supply of VRF Airconditioning Units Microprocessor based Outdoor units shall be provided with twin rotary/scroll compressor. It shall be equipped with inverter controller and capable of changing the rotating speed to follow variations in cooling. Outdoor units shallbe suitable for mix-match connection of all type of indoor units. Indoor & Outdoor unit shall be factory assembled, tested and filled with first charge of refrigerant before delivery at site. All compressors shall be of 100% inverter type. Outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels with powder coated finish. All outdoor units above 6 HP rating or in case of with multiple compressors shall be with 3D scroll compressors. The noise level shall not be more than 60 dB A at 1 m distance horizontally and 1.5 m above ground level. All necessary safety devices like high pressure switch, low pressure switch, fuse, crankcase heater, fusible plug, over current protection for Inverter, short cycling guard timer, single phase preventer, Anti Harmonic Filter etc.,. Refrigerant pipe circuit shall include refnets, liquid receiver / accumulator, liquid & gas shut off valves and solenoid valve. Refrigerant pipe shall be in high grade copper (16G) of refrigeration quality with Eddy current testing & material test certificates. All connections like tees, reducers etc shall be standard make fittings. Cold lines shall be insulated to avoid the condensation. For individual piping 50 / 100 mm wide Al tape shall be used at joints of piping with Bands for identification. For Outdoor piping, the finish shall be woven GRP Mat finished with colored Epoxy paints and enclosed with GI trays to avoid physical damage.All Indoor units shall have electronic expansion valve, adequate insulation to avoid condensation. Coils shall be anti-corrosive. Control wiring between Indoor & Outdoor shall be part of VRF supplier scope. Outdoor must be equiped with multi compressor & should be run on failure of any of one compressor. To have provision for potential free contact-to get signal from BMS in case of fire -so that AC can get shut off. All accessories for installation / commissioning should be part of the package ( VRF Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 22 HP
230Supply of VRF Airconditioning Units Microprocessor based Outdoor units shall be provided with twin rotary/scroll compressor. It shall be equipped with inverter controller and capable of changing the rotating speed to follow variations in cooling. Outdoor units shallbe suitable for mix-match connection of all type of indoor units. Indoor & Outdoor unit shall be factory assembled, tested and filled with first charge of refrigerant before delivery at site. All compressors shall be of 100% inverter type. Outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels with powder coated finish. All outdoor units above 6 HP rating or in case of with multiple compressors shall be with 3D scroll compressors. The noise level shall not be more than 60 dB A at 1 m distance horizontally and 1.5 m above ground level. All necessary safety devices like high pressure switch, low pressure switch, fuse, crankcase heater, fusible plug, over current protection for Inverter, short cycling guard timer, single phase preventer, Anti Harmonic Filter etc.,. Refrigerant pipe circuit shall include refnets, liquid receiver / accumulator, liquid & gas shut off valves and solenoid valve. Refrigerant pipe shall be in high grade copper (16G) of refrigeration quality with Eddy current testing & material test certificates. All connections like tees, reducers etc shall be standard make fittings. Cold lines shall be insulated to avoid the condensation. For individual piping 50 / 100 mm wide Al tape shall be used at joints of piping with Bands for identification. For Outdoor piping, the finish shall be woven GRP Mat finished with colored Epoxy paints and enclosed with GI trays to avoid physical damage.All Indoor units shall have electronic expansion valve, adequate insulation to avoid condensation. Coils shall be anti-corrosive. Control wiring between Indoor & Outdoor shall be part of VRF supplier scope. Outdoor must be equiped with multi compressor & should be run on failure of any of one compressor. To have provision for potential free contact-to get signal from BMS in case of fire -so that AC can get shut off. All accessories for installation / commissioning should be part of the package ( VRF Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 24 HP
231VRF Indoor Units (Ground Floor) Supply of Ceiling mounted reguar Cassette Unit with Panel, drain pump. Size : 950 X 950 (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 3.2 TR
232VRF Indoor Units (Ground Floor) Supply of Ceiling mounted reguar Cassette Unit with Panel, drain pump. Size : 950 X 950 (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 4.0 TR
233VRF Indoor Units (First Floor) Supply of Ceiling mounted reguar Cassette Unit with Panel, Filter, Drain pump. Size : 950 X 950 (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 3.2 TR
234VRF Indoor Units (First Floor) Supply of Ceiling mounted reguar Cassette Unit with Panel, Filter, Drain pump. Size : 950 X 950 (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) 4.0 TR
235Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 350 CFM / 20MM ESP - Exhaust Air Fan
236Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 350 CFM / 20MM ESP - Fresh Air Fan
237Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 425 CFM / 20MM ESP - Exhaust Air Fan
238Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 425 CFM / 20MM ESP - Fresh Air Fan
239Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 800 CFM / 20MM ESP - Exhaust Air Fan
240Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 800 CFM / 20MM ESP - Fresh Air Fan
241Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 825 CFM / 20MM ESP - Exhaust Air Fan
242Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 825 CFM / 20MM ESP - Fresh Air Fan
243Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 1050 CFM / 20MM ESP - Exhaust Air Fan
244Toilet Ventilation Fans Supply Of Ceiling Suspended Ventilation Fan Unit As Per Specs (Make : Airflow / Nicotra / Greenheck) Supply, installing, testing, commissioning & handing over of INLINE FRESH / EXHAUST Air Fan in accordance with and meeting the intents & specifications & drawings complete with Fan with Drive Motors, Mild Steel Mounting Frame, Vibration Isolators, Gravity louvers. (NOTE : SUBJECT TO ACTUAL STATIC PRESSURE CALCULATION. ON SHOP DRAWINGS BY CONTRACTOR AND APPROVAL OF CONSULTANT) 1050 CFM / 20MM ESP - Fresh Air Fan
245Copper Refrigerant Joint Supply Of OEM make refrigerant joints (Make : Mitsubishi Heavy / O General / Mitsubishi Electric)
246Cordless Remote Controller Supply Of OEM make Cordless Remote Controller with stand and batteries (Make : Mitsubishi Heavy / O General / Mitsubishi Electric)
247Central Remote Controller Supply Of OEM make Central Remote Controller (Make : Mitsubishi Heavy / O General / Mitsubishi Electric) Central Remote Controller Monitoring & control of temperature of each Area & Units ON/OFF control for each Area & Units Weekly scheduling for each Area & Units Overriding of control function of individual control units Scheduling & historical data storage of conditions as per requirement LCD Display Panel To be integrated with Fire Panel To be installed at Reception Area. And should be opearted from PC It should be compatible with latest microsoft version. *In case the no. IDUs / ODUs is beyond the capability of a single CRC, then the rate quoted here should include cost of add-on modules / multiple CRCs / cabling.
248Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of VRF Outdoor. Also it should include first oil & gas charge & commissioning etc. complete 20 HP
249Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of VRF Outdoor. Also it should include first oil & gas charge & commissioning etc. complete 22 HP
250Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of VRF Outdoor. Also it should include first oil & gas charge & commissioning etc. complete 24 HP
251Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. ( Ground Floor ) 3.2 TR
252Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. ( Ground Floor ) 4.0 TR
253Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. ( First Floor ) 3.2 TR
254Lifting, Shifting, Positioning, Installtion, Testing & Commissioning of Regular Cassette Units Indoor with accessaries like required Cassette panel, support plate, , Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. ( First Floor ) 4.0 TR
255Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 350 CFM / 20MM ESP - Exhaust Air Fan
256Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 350 CFM / 20MM ESP - Fresh Air Fan
257Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 425 CFM / 20MM ESP - Exhaust Air Fan
258Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 425 CFM / 20MM ESP - Fresh Air Fan
259Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 800 CFM / 20MM ESP - Exhaust Air Fan
260Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 800 CFM / 20MM ESP - Fresh Air Fan
261Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 825 CFM / 20MM ESP - Exhaust Air Fan
262Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 825 CFM / 20MM ESP - Fresh Air Fan
263Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 1050 CFM / 20MM ESP - Exhaust Air Fan
264Lifting, Shifting, Assembling, Positioning, Installtion, Testing & Commissioning of Vetilation Fans with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc. 1050 CFM / 20MM ESP - Fresh Air Fan
265Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Copper refrigerant joints with accessaries like required support plate,Threaded rods of 10mm Thk, Anchor fastner, nut bolts, Washer & screws etc.
266Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Cordless Remote with baseplate, nut bolts, Washer & screws etc.
267Lifting, Shifting,Positioning, Installtion, Testing & Commissioning of Central Remote with cable termination with lugs, baseplate, nut bolts, Washer & screws etc.
268SITC OF Refrigerant Piping between indoor & ourdoor units Refrigerant Hard copper piping suitable gauge as sugested by OEM of VRF System duly insulated with required 19mm thickness closed cell electrometric Nitrile Rubber covered interconnecting indoor & outdoor unit. Metallic foil membrane shall be applied to provide resistance against breakdown due to UV radiation for exposed portion of the Rubber Insulation on terrace. The refrigerant piping shall be laid with proper supports as required. Suction & Descharge circuit shall be considered as a single circuit to measure the length. Single length of circuit shall be considered for each unit to measure the length
269SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) Providing and fixing in position the following PVC condensate drain pipes cut to required lengths and necessary elbows, tees and reducers, hanger, supports, fittings and with 12mm thk. Nitrile Rubber Insulation as per drawing. Quoted price shall be inclusive of adhesive, nitrile rubber tape, supports etc. as per specification and drawing. Make : Finolex / Astral / Ashirvad SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) 25mm ( 10 KG )
270SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) Providing and fixing in position the following PVC condensate drain pipes cut to required lengths and necessary elbows, tees and reducers, hanger, supports, fittings and with 12mm thk. Nitrile Rubber Insulation as per drawing. Quoted price shall be inclusive of adhesive, nitrile rubber tape, supports etc. as per specification and drawing. Make : Finolex / Astral / Ashirvad SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) 32mm ( 10 KG )
271SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) Providing and fixing in position the following PVC condensate drain pipes cut to required lengths and necessary elbows, tees and reducers, hanger, supports, fittings and with 12mm thk. Nitrile Rubber Insulation as per drawing. Quoted price shall be inclusive of adhesive, nitrile rubber tape, supports etc. as per specification and drawing. Make : Finolex / Astral / Ashirvad SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) 50mm ( 10 KG )
272SITC of Condensate Piping (FOR ALL AIR CONDITIONERS ) Providing and fixing in position the following PVC condensate drain pipes cut to required lengths and necessary elbows, tees and reducers, hanger, supports, fittings and with 12mm thk. Nitrile Rubber Insulation as per drawing. Quoted price shall be inclusive of adhesive, nitrile rubber tape, supports etc. as per specification and drawing. Make : Finolex / Astral / Ashirvad SITC of Control Cabling ( FOR ALL AIRCONDITIONERS ) 2.5 Sq.MM x 3C Shielded Control cabling with necessary conduiting between indoor and outdoor units & central remote controller
273Air Distribution System: SITC of Metal Ducts Supply, fabrication, installation of sheet metal RECTANGULAR/ROUND DUCTS complete with all accessories like flanges, all necessary MS supports with epoxy Painting, suspension rods , anchor bolts, GI bolts & nuts, canvas connections , adjustable splitter , guide vanes including air balancing with necessary connections etc., in accordance with the approved shop drawings and as per the specifications : GI Sheet : Essar / Jindal / Tata RECTANGULAR DUCT 0-750mm:24 Gage(0.70mm)(4 Bolt TDC)
274SITC of Air Terminals Supply and Installation of Air grilles, diffusers & louvers, complete with all accessories, supports, anti smudge ring& removable core etc., to compete the work as per specifications, drawings and all related documents. Color to be confirmed with architect Make : Airflow / Sachins / Trox Air Grille with powder coated extruded & aluminium volume control damper
275SITC of Air Terminals Supply and Installation of Air grilles, diffusers & louvers, complete with all accessories, supports, anti smudge ring& removable core etc., to compete the work as per specifications, drawings and all related documents. Color to be confirmed with architect Make : Airflow / Sachins / Trox GI Duct Volume control damper
276SITC of Fire retardant canvass connection
277MS FRAME WORK M. S. frame type structure for installing outdoor units duly epoxy coated / galvanized.
278ALL IN ALL AMC RATES APPLICABLE AFTER GUARANTEE PERIOD for HVAC WORKS: (RATE SHOULD BE INCLUSIVE OF ALL TAXES) For 1st Year After Completion of DLP
279ALL IN ALL AMC RATES APPLICABLE AFTER GUARANTEE PERIOD for HVAC WORKS: (RATE SHOULD BE INCLUSIVE OF ALL TAXES) For 2nd Year After Completion of DLP
280ALL IN ALL AMC RATES APPLICABLE AFTER GUARANTEE PERIOD for HVAC WORKS: (RATE SHOULD BE INCLUSIVE OF ALL TAXES) For 3rd Year After Completion of DLP
281ALL IN ALL AMC RATES APPLICABLE AFTER GUARANTEE PERIOD for HVAC WORKS: (RATE SHOULD BE INCLUSIVE OF ALL TAXES) For 4th Year After Completion of DLP
282ALL IN ALL AMC RATES APPLICABLE AFTER GUARANTEE PERIOD for HVAC WORKS: (RATE SHOULD BE INCLUSIVE OF ALL TAXES) For 5th Year After Completion of DLP
283ELECTRICAL WORKS: Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor typecubical panel board having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection, supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuringinstruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (The rates includes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips,meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers as per attached SLD - MAIN LT Panel (as per attached Single Line diagram)
284Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used)- Three phase 8 way SS Double door for horizontal single phase outgoing
285Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used)- (H) Single phase 12 way SS Double door
286Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark - SP MCB
287Providing & erecting 240 V MCB double pole switch for motor & inductive load(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp. - DP MCB
288Providing & erecting 240 V MCB double pole switch for motor & inductive load(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 40Amp. - DP MCB
289Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity6 to 32 Amp.
290Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity40 Amp.
291Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity63 Amp.
292Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed 25 Amps.DP
293Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed 40 Amps.DP
294Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed 63 Amps.DP
295Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. - Double Pole / Four Pole
2961.2KV Protection level FP, Class "s", (Imax-15KA, 8/20µS) LEGRAND Cat no.3943 or Equivalent
2971.2KV Protection level DP, Class "s", (Imax-15KA, 8/20µS) LEGRAND Cat no. 3941 or Equivalent
298Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to250A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
299Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
300Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS.
301Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
302Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. Supplying & erecting power contactor for time switch complete erected as per direction Cat III 4 pole 440V 40 Amp.
303Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the faultall over the run and backfilling the same and making the surface as normal ground.
304Covering of cable with second class bricks or cement tileslaid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)
305Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables.(a) 4 core 2.5 Sq. mm
306Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables.(a-1) 4 core 4 Sq. mm
307Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables(c) 4 core 10 Sq. mm
308Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables(d) 4 core 16 Sq. mm
309Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables (A) 3 1/2core 25 Sq. mm ( 16 Sq. mm 1/2 core)
310Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables (G) 3 1/2core 185 Sq. mm ( 95 Sq. mm1/2 core)
311Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (b) 4 core 4 Sq. mm/ (a) 4 core 2.5 Sq. mm
312Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 4 core 6 Sq. mm
313Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 10 Sq. mm
314Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 3& 1/2 core 25 Sq. mm
315Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (G) 3& 1/2 core 185 Sq. mm
316Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments
317[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.150mm x 150mm x 60/75 mm depth
318[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.300mm x 300mm x 60/75 mm depth
319Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % -- Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 -Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr.
320(E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr.
321Fabrication : Supplying , fabricating and installation of various sizesclamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
322HEAT / FIRE RESISTANT COATING OF CABLE Supply and application of intumescent based coating on cables/ cable tray using CP 678 firestop cable coating of HILTI make or equivalent. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992).
323Point wiring for Light Point / Bell with2-1.5 sq.mm& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type ofpipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuityof following type, erected on PVC / Metallic box, single mounting base framecovered with textured/metallic front plate modules erected on /in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories
324Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipeto be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (a) 2 wire 1.5 sq. mm
325Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipeto be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm
326Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type ofpipe to be erected concealed in / flushed on wall/ceiling,complete with earth continuity and necessary connection with primary light with accessories erected onMetal /PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheetfor open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
327Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm& earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
328Point wiring for FAN with 2-1.5 sq.mm& earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV GradeFRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted andaccessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
329Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erectedon/ in wall / ceiling with following type accessories
330Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. ( Plug & Switch can be together or at different location )
331Point wiring for Individual Plug with& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plugerected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
332Point wiring for Individual Plug with& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plugerected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
333Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slabor Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
334Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slabor Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
335Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slabor Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness
336Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (B) 50 mm Dia. (2.5Kg/6RMT)
337Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (D) 75 mm Dia (5.5 Kg / 6RMT)
338Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (E) 90 mm Dia (8.0 Kg / 6RMT)
339Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery
340Computer : Power Plugs 1 no. universal plug-switch combined + 1 Nos swithc for Below table 2 nos. 6A 5 pin Plug as below Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erectedon/ in wall / ceiling with following type accessories Cat. III + Point wiring for Individual Plug with& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plugerected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire (Car.iii) +[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire (Car.iii)
341Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 4 sq. mm
342Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 6 sq. mm
343Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 10 sq. mm
344Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. It should be BLDC motor -5, 320RPM, 30-35W 5-Star rating Power saving Fan
345Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
346Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [C] 380 mm dia 1400 RPM
347Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [D] 450 mm dia 900 RPM
348Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
349Supply,installation, testing and commisioning of Internal light fixtures of 600mm long LED Tube light (14W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
350Supply,installation, testing and commisioning of IP-65 Surface Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
351Supply,installation, testing and commisioning of IP-65 Surface Mounted 16W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
352Supply,installation, testing and commisioning of IP-20 Recessed Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
353Supply,installation, testing and commisioning of IP-65 Recessed Mounted 18W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
354Supply,installation, testing and commisioning of Wall Mounted IP-65 2x6W LED up-down light with die cast construction, Double reflector, toughened glasscover with LED lamp and driver.-PF>0.9 ,THD <20% ,Make : Trilux, Wipro, Philips
355Supply,installation, testing and commisioning of IP-65 -IK 07,10-12W LED Bollard light with die cast aluminum die cast powder coated housing, reflector,with LED lamp and driver.Make : Trilux, Wipro, Philips
356Supply,installation, testing and commisioning of IP-65 3-6W LED foot light with die cast aluminum 150-200 mm long Recessed / surfaced, IP-65 powder coated housing, reflector, toughened glass cover with LED lamp and driver. Make : Trilux, Wipro, Philips
357Supply,installation, testing and commisioning of IP-65 3-6W LED Spike light with die cast aluminum 300 mm long spike, powder coated housing, reflector, toughened glass cover with LED lamp and driver. Make : Trilux, Wipro, Philips
358Supply,installation, testing and commisioning of Recccesed light fixtures suitable for Tech Zone ceiling size of 150wide x 2400mm long LED Tube light (28W) with Micro Prismatic Diffuser,4kv SPD Matt Steel Grey Extruded Aluminum Body with system luman output minimum 2800 lm. Make : Trilux, Wipro, Philips
359Supply,installation, testing and commisioning of Suspended Linear light fixtures Aircraft Grade Aluminum Body, 820mm Long, 110W and Having a powder coading color with UV Protection as per selection,4kv SPD Matt Steel Grey Extruded Aluminum Body, Super Luman Output 125Lm/W, Value Luman OutPut 110Lm/W with system luman output minimum 12000 lm. Make : Tucana, Trilux, Philips
360Supply,installation, testing and commisioning of IP-68 6-10W LED Swimming Pool light with die cast aluminum 50-150 mm dia Recessed, IP-68 powder coated housing with external Driver if require, toughened glass cover with LED lamp and driver. Make : Trilux, Wipro, Philips
361Supply,installation, testing and commisioning of Suspended light fixtures Aluminum Body, 600-900mm dia, 35-45W and Having a powder coading color as per selection with UV Protection as per selection,4kv SPD Matt Steel Grey Extruded Aircraft grade Aluminum Body with system luman output minimum 120LM/W . Make : Tucana, Trilux, Philips
362Supply,installation, testing and commisioning of LED Strip light 10-12W . Mtr with external Driver if require, driver. Make : Trilux, Wipro, Philips
363Supply,installation, testing and commisioning of IP-65 35-40W LED Each LED Lmap Post made up of die cast aluminum, powder coated IP-65 housing, reflector, toughened glass cover with LED lamp and driversuitable for mounting on 3.0 Mtr FRP Light Pole. Make : Trilux, Wipro, Philips, K-Lite
364Supplyof approved make GRP / FRP Polehaving following specifications: GRP Light Pole made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. The pole should be in one piece and tapered round in shape, having smooth finish and should be totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint. Pole should be flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not exceed more than 10% of the length of pole for the given load“? Pole should be generally made as per the dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI C 136.20 latest version or ASTM D 4923/01 . The size of pole and type of installation are as below . [B] Overall length of 3 Mtr Average Thickness: 7mm. Top/ Bottom OD Dia A/F 89/130mm ± 2mm approx. Weight of Pole: 12 kg apporx. (Without Base) Anchor Base (Size 250X250 &12mm th.)
365Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
366Supplying & erectingapproved makeSMC press moulded composite FRP.loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.: (b) 250mm x 200mm x 100mm [deep]
367Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipeshaving Outer pipedia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nosBags of 25 Kg.
368Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipeshaving Outer pipedia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg.
369Supplying & erecting of Conventional Lightening arrestor with Test loop and Counter as per IS standard
370Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp.
371Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
372Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slabor Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
373Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erectedwith necessary connection. (8) Modem Jack for Computer Open RJ-45 - cat-III
374Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erectedwith necessary connection. (3) Two Pin/RJ-11 Telephone Socket for One Gong Bell - cat-iii
375Supplying & erecting Push button type telephone instrument (A)BEETEL Secure / BPL/, SONY / PANASONIC or equivalent make
376Supplying & erecting approved make LAN cable of following size in existing pipe as per direction : [C] CAT - 6
377Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 10 Pair
378Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slabor Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
379Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-6 Cable
380Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-11 Cable
381Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erectedwith necessary connection. for (4) TV Co-axial Socket outlet
382Supply, Installation, Testing and Commissioning of 5 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Indoor IR Eyeball, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR,DWDR, 3.6mm lens, 4 IN 1
383Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR,DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT
384Supply, Installation, Testing and Commissioning of 16-Channel DigitalVideo Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 16-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
385Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards complete as required (if required). Make - Sony, Samsung, Philips
386Supply, Installation, Testing and Commissioning Power Supply for Camera
387Supply, Installation, Testing and Commissioning CCTV cable in 25mm dia PVC Pipe 3+1 Camera Cable
388Supply installation testing and commissioning High Speed quick power charging station for Electrical vehicle as per standard voltage rating with 40A FP MCB and 2 Nos 6A power plugs, it should have digital screen and all parameter recorders.
389Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor,supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter,and inverter as require with consideration of 1-Year DLP (1KW Each)
390AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 1st Year after DLP (period 3% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
391AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 2nd Year after DLP (period 3.5% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
392AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 3rd Year after DLP (period 4% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
393Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 1st Year Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc
394Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 2nd Year Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc
395Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 3rd Year Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc
396Supplyinhg certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 4th Year Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc
397Liaoning with Local Electricity Board & Electrical Inspector for upgradation of Existing11KV HT Power & Electrical inspector certification in totality to charge the power other related accessories. etc. complete. Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
398Liaoning with local authority / Fire Dept for roof top solar system Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.