Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BOQ UPLOADED ON 04 SEP 2021 |
| 2 | SCH \"A\" PART-I (CIVIL WORKS) |
| 3 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 150mm thickness (below or above ground level) and removal of unserviceable debris outside of MD land complete all as specified and as directed. |
| 4 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depthand getting out in any type of soil all as specified and as directed. |
| 5 | Excavating in trenches, exceeding 1.5m wide and not exceeding 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depthand getting out in any type of soil all as specified and as directed. |
| 6 | Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | Reinforcedcementconcrete,RCCM-30, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed. |
| 8 | Providing precast cement concrete type 1:2:4, type B1 (using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed. |
| 9 | Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed. |
| 10 | Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. |
| 11 | Mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. |
| 12 | Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed. |
| 13 | Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed. |
| 15 | Spreading, levelling the excavated material in floors or pavings laid in layers not exceeding 15CM thick and rammed including watering complete all as specified and as directed. |
| 16 | Rolled mild steel as in joists, channel, angle or tee sections, fixed independently, without connecting plates etc., (cut to ordinary lengths i.e within 20mm of the length indicated) ofFe-410-W (Gde E-250 quality A)complete all as specified and as directed. |
| 17 | Rolled mild steel of grade Fe-410-W (Gde-E-250) Quality-A as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, riveted, bolted or welded complete all as specified and as directed. |
| 18 | Rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces., cleatsetc., ofFe-410-W (Gde E-250 quality A)complete all as specified and as directed. |
| 19 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding5cm butnot exceeding 10cm and diameter of neck 5mm to 10mm complete all as specified and as directed. |
| 20 | Welded steel wire fabric of weight not exceeding 4Kg per sqm and fixed to steel memberscomplete all as specified and as directed. |
| 21 | Cutting holes into or through brick walls built in cement mortar of superficial area not exceeding150 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 22 | Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish to a distance not exc. 50mcomplete all as specified and as directed. |
| 23 | Taking down chowkats or frames(wooden / steel) with shutters(without taking off shutters from the frames) exceeding 1.50 sqm butnot exceeding 4.00 sqmeach and removing from site under Sch of credit complete all as specified and as directed. |
| 24 | Taking down chowkats or frames (wooden / steel) with shutters(without taking off shutters from the frames) not exceeding 1.50 sqmeach and removing from site under Sch of creditcomplete all as specified and as directed. |
| 25 | Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, as in IInd class hardwood complete all as specified and as directed. |
| 26 | Plain, framed, panelled shutters (any number of panels), of IInd class hardwood, 35mm thick with panelsof wood particle board with commercial face veneers complete all as specified and as directed. |
| 27 | Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed. |
| 28 | Butt hinges, medium weight, cold rolled mild steel and fixed / welded to frame of size 100mm complete all as specified and as directed. |
| 29 | Extruded aluminium alloy handles,cast type, anodised of size 150mm complete all as specified and as directed. |
| 30 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 150mm complete all as specified and as directed. |
| 31 | Ordinary rat tail rod pattern springs, 300mm, mild steel, including roller and roller plate complete all as specified and as directed. |
| 32 | Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 33 | Preparing old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 34 | Plain cement concrete, type C1, 1:3:6, using 20mm graded granite stone aggregate as in bed blocks andthe like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed. |
| 35 | Mild steel as in small articles such as hold fast, wall ties, bands, straps and like conforming to Fe-290 Grade-E-165 complete allas specified and as directed. |
| 36 | Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqmbut not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding complete allas specified and as directed. |
| 37 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as per relevant drawing in SSR Part-IIcomplete all as specified and as directed. |
| 38 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatmoulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in frames as per relevant drawing in SSR Part-IIcomplete all as specified and as directed. |
| 39 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 100mm complete all as specified and as directed. |
| 40 | Butt hinges, extruded aluminium alloy, with mild steel hinge pin, anodised, type C-21 of size 100mm complete all as specified and as directed. |
| 41 | Extruded aluminium alloy handles, fabricated type, anodised of size 150mm complete all as specified and as directed. |
| 42 | Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat primer complete all as specified and as directed. |
| 43 | Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat prime complete all as specified and as directed. |
| 44 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe-290, Gde-E-165complete all as specified and as directed. |
| 45 | Sheet glass, 3mm thick, ordinary quality and glazing with oil putty in squarenot exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 46 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 47 | Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 48 | Preparing old painted surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 49 | Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 50 | Aluminium snap grid framework (powder coating of minimum 50 microns) of grid size 605mm x 605mm of main and cross tee of size 40mm x 25mmx 1.5mm thick and wall angle size 25mm x 25mm x 1.5mm thick for false ceilingincluding fixing of supporting hangerscomplete all as specified and as directed.Note: The hangers for support of false ceiling shall be measured and paid separately. |
| 51 | Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 52 | PVC insulation panels 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium complete all as specified and as directed. |
| 53 | Surface excavation not exceeding 30 cm deep averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed. |
| 54 | Brick work with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specifed and as directed. |
| 55 | Brick work with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius in half brick thick wall built in cement mortar 1:4 of designation 50 complete all as specifed and as directed. |
| 56 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of conctrete complete all as specified and as directed. |
| 57 | RCC Design mix M-30 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 58 | Formwork to chullah hoods, chajjas, fins, facia, troughs and similar items including edges for rough finished flat surfaces of conctrete complete all as specified and as directed. |
| 59 | RCC Design mix M-30 as in chajja, facia and the like complete all as specified and as directed. |
| 60 | Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) for rough finished flat surfaces of conctrete complete all as specified and as directed. |
| 61 | RCC Design mix M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 62 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as requiredto facilitate demolition) and removal of unserviceable debris to outside of MD land complete all as specified and as directed. |
| 63 | Complete removal of existing water proofing treatmentincludingwater proofing plaster, cement mortar screed etc., and demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for andremoval of unserviceable debris out ofMD land complete all as specified and as directed |
| 64 | Note:- |
| 65 | The entire thickness including the water proofing treatment shall be measured in cubical content. |
| 66 | Plain cement concrete as in levelling course averaging 40mm thick including making good depressions / undulations,1:2:4, type B0, using 12.50mm graded stone aggregate mixed with water proofing compound and finished to receive plastering complete all as specified and as directed. |
| 67 | Note:- |
| 68 | Supply only Water proofing compound shall be measured and paid separately. |
| 69 | Rendering 10mm thick in CM(1:3) over levelling coursewhen the concrete is green, mixed withwater proofing compound and finished even and smooth without using extra cement complete allas specified and as directed. |
| 70 | Note:- |
| 71 | Supply onlyWater proofing compound shall be measured and paid separately. |
| 72 | Supply onlyWater proofing compound all as specified and as directed. |
| 73 | Preparing the rendered surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS 702 over a coat of bitumen primer @ 0.40 Litres / Sqm followed by APP membrane reinforced with polyster non woven fabric 3mm thick weighing not less than 3.6 kg / sqm laid on primed surface by forced application followed by a finishing coat of solar reflective aluminium paint @ 0.10 litres / Sqm complete all as specified and as directed. |
| 74 | Note:- |
| 75 | For detailed specifications please refer particular specifications and list of manufacturers givenhere-in-after and the rate rate quoted shall include for the same. |
| 76 | Taking down cement plaster any description on brick or stone walls, concrete surfaces, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. andremoval of unserviceable debris to outside of MD land complete all as specified and as directed. |
| 77 | Rendering 15mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 78 | Rendering 10mm thick in CM(1:6) with a top coat of rendering 5mm thick in CM(1:4) mixed with water proofing compound on fair faces of brickwork or concrete surfaces finished even and fair without using extra cement complete allas specified and as directed. |
| 79 | Rendering 5mm thick in CM(1:3) on ceiling surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 80 | Preparing newly plastered surfaces of wall,,applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed |
| 81 | Complete removal of existing treatment from wall surfaces,applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed |
| 82 | Preparing newly plastered surfaces of ceiling and applying three coats of white wash including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 83 | Preparing old plastered surfaces of ceiling and applying one coat of white wash on plastered ceiling surfaces including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 84 | Preparing newly plastered surfaces of wall, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint,complete all as specified and as directed |
| 85 | Complete removal of existing treatment from wall surfaces, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint complete all as specified and as directed |
| 86 | Preparing newly plastered surfaces of wall and applying three coats of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 87 | Preparing old plastered surfaces of wall and applying one coat of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 88 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 89 | Plain cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate, 75mm thick as in sub-base to floor complete all as specified and as directed. |
| 90 | Plain cement concrete 25mm thick, type B0, 1:2:4, using 12.5mm graded stone aggregate,surface finished even and smooth without using extra cement as in floor complete all as specified and as directed. |
| 91 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeeding 0.38 sqm (600mm x 600mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed. |
| 92 | Glazed ceramic tiles coloured of size 300mm x 200mm,minimum 7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed. |
| 93 | Hardcore broken stone boulders of guagenot exceeding 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 94 | Plain cement concrete 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate as in plinth protection surface finished fair and even complete all as specified and as directed. |
| 95 | Forming Construction joint 65mm deep x 10mm wide filledwith sealing compound grade \"A\" complete all as specified and as directed. |
| 96 | Powder coated aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc.complete all as specified and as directed. |
| 97 | Powder coatedaluminiumslidingwindows,allasgiven here-in-aftercompleteallasspecifiedandasdirected. Frame:-Three track section shall be of weight not less than1.060 kg/m. Shutter:-Consists of 03 Nos Shutters i.e 02 Nos od Glazed shutters and 01 No of Gauzed shutter. Sections of shutter (stiles and rails) sections shall be of weight not less than 0.562 kg/m. Builders hardware:-Standard locking device for glazed shutters. |
| 98 | Note:- |
| 99 | (a) All aluminium sections including glazing clips, snap beading, joining cleats, rubber packing, screws etc.,as required are deemed to be included in the rate quoted. |
| 100 | (b) Glass or wire cloth as required shall be measured and paid separately. |
| 101 | (c) The fixtures given are for window unit of size exceeding 1.0 sqm but not exceeding 2.20 sqm. |
| 102 | Prelaminated particle board minimum 9mm thick, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination complete all as specified and as directed. |
| 103 | Sheet glass, 4mm thick, ordinary quality and glazing with aluminium beading in squarenot exceeding 0.5 sqm in each panecomplete all as specified and as directed. |
| 104 | Veneered decorative plywood, grade 1 (with BWR resin) withdecorative face veneers with screws to timber frame work complete all as specified and as directed. |
| 105 | 50mm dia, polished, hard wood knobs fixed with screws complete all as specified and as directed. |
| 106 | Roughening surfaces of old concrete surface by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry at the rate of 3.0kg of cement per square metre complete all as specified and as directed. |
| 107 | Concrete flooring 125mm thick with RMCM-20 grade using (design Mix) vaccum dewatering method, laid in alternate bays including steel form work of MS channel sections of depth equal to thickness of concrete floor and trowelled with power trowel float finish to obtain level and joints filled with sealing compound complete all as specified and as directed. Note: Joint filling sealing compound shall be measured and paid seperately under respective item. |
| 108 | Wear proof topping 15mm thick (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complte all as specifed and as directed.Note: Metallic hardner as required shall be measured and paid seperately. |
| 109 | Supply only of metallic hardner to be incorporated in wear proof topping complete all as specified and as directed and as per manufacturer\"s instructions. |
| 110 | Forming 12 mm thick expansion joints filled with pre-formed bituminous filler 100mm depth and top 30mm shall be primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed. |
| 111 | Demolition of brickwork or stone boulder masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed. |
| 112 | Brick work with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 of designation 50 complete all as specifed and as directed. |
| 113 | Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set,jointed and pointed in chemical resistant mortar, resin type, infloors in floors etc, over cement screed 1:4, 20mm thick complete all as specified and as directed. |
| 114 | Acid resistance tileminimum 7mm thickset, jointed and pointed in chemical resistant mortar, resin type in vertical surfaces such as skirting, dados, risers etc, including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed. |
| 115 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specifed and as directed. |
| 116 | Electrically operated M S Rolling shutter with 10 SWG guide channel, 18 gauge flate lath strip, 1mm thick intwerlocking together and fixed with end locking on both side roller section with bearings complete with one coat red oxide primer paint industrial side motor with break for automation of rolling shutter including push button switch, chain block arrangement for the manual operation including cable arrangement upto 10m length complte all as directed. |
| 117 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed. |
| 118 | Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 20mm complete all as specified and as directed. |
| 119 | Gun metal, globeor gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 20mm complete all as specified and as directed. |
| 120 | Sand filling in floors or pavings laid in layers not exceeding 15CM thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 121 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of conctrete complete all as specified and as directed. |
| 122 | RCC Design mix M-30 as in Columns, pillars, piers,posts and struts complete all as specified and as directed. |
| 123 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete allas specified and as directed. |
| 124 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified and as directed. |
| 125 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 126 | Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. |
| 127 | Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snabeading, screws etc. complete all as specified complete all as specified and as directed. |
| 128 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS-1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to existing window frame with CP brass / stainless steel screws at 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium section around the opening , complete all as specified and as directed. |
| 129 | Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed. |
| 130 | Aluminium Mortice lock, vertical type, size 100 mm4 lever complete all as specified and as directed. |
| 131 | Aluminium (Die cast) body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 132 | Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm including fixing on floor complete all as specified and as directed. |
| 133 | Sheet glass, ordinary quality, 5.5mm thick, and glazing with aluminium snap beading in squarenot exceeding 0.5 SQUARE METRE in each pane complete all as specified and as directed. |
| 134 | Frosted sheet glass, 4mm thick, ordinary quality and glazing with aluminium snap beading in squarenot exceeding 0.5 SQUARE METRE in each pane complete all as specified and as directed. |
| 135 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a)quality over cement screed 1:4, 20mm thick complete all as specified and as directed. |
| 136 | Glazed ceramic tiles of grade B-III coloured of size 350mm x 250mm/ 450mm x 350mm, minimum 7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed. |
| 137 | Prelaminated particle board minimum 18mm thick, exterior grade, one side prelaminated with decorative choice lamination and other side balancing white fixed to timber/aluminium frame complete all as specified and as directed. |
| 138 | Continuous (piano) hinges, mild steel, bright finish or electrogalvanised 30mm width of flap complete all as specified and as directed. |
| 139 | 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished complete all as specified and as directed. |
| 140 | Dismantling existing water tanks, exceeding 500 litres and not exceeding 1000 litres, and taken on creditcomplete allas specified and as directed. |
| 141 | Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) , three layered hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and as directed. |
| 142 | Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 15mm complete all as specified and as directed. |
| 143 | Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 20mm complete all as specified and as directed. |
| 144 | Steel water tubing, medium grade galvanised with all fittings like bends, elbows, reducers, unions, tees etc and fixed complete to walls and ceilings or laid in floor of bore of pipe 15mm complete all as specified and as directed. |
| 145 | Angle valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore of pipe 15mm as in repairs complete all as specified and as directed. |
| 146 | Bib taps, chromium plated, brass fancy type, long body, screwed down, screwed both ends for iron pipe or for brass ferrule and fixed of bore of pipe 15mmas in repairs complete all as specified and as directed. Prayag Cat No 8308 or equivalent makes listed here-in-after. |
| 147 | Towel rail, stainless steel tubular, fancy type 600mm long with hooks complete all as directed.Make : Prayag Cat No BA 80 or equivalent makes listed here-in-after. |
| 148 | Toilet paper holder brass, chromium plated, fixed to walls with chromium plated brass screwscomplete all as specified and as directed. Make : Prayag Cat No BA 88 or equivalent makes listed here-in-after. |
| 149 | Soap dish fixed to plugs with chromium plated brass screwscomplete all as specified and as directed. Make : Prayag Cat No BA 25G or equivalent makes listed here-in-after. |
| 150 | PVC (SWR) floor trap, plain with grating of diameter of outlet 75mm including jointing with solvent cementcomplete all as specified and as directed. |
| 151 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 110mm as in repairs complete all as specified and as directed. |
| 152 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 75mm as in repairs complete all as specified and as directed. |
| 153 | PVC (SWR) bend any radius of bore 75mm complete all as specified and as directed. |
| 154 | PVC (SWR) bend any radius of bore 110mm complete all as specified and as directed. |
| 155 | PVC (SWR) branch piece, single (single Y) equal or unequal of bore 75mm complete all as specified and as directed. |
| 156 | Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with \"P\" or \"S\" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed. |
| 157 | Note:- |
| 158 | Flushing cistern, flush pipe, seat cover, P trap, WC connector,as required shall be measured and paid for under supply only separately. |
| 159 | Supply only PVC valveless, syphonic action type flushing cistern 10 litres capacity low level, white with inlet, ball valve, float and handle / push button, including brackets complete all as specified and as directed. |
| 160 | Supply only flush pipe of polyethylene of high density, 32mm dia for low level / high levelflushing cistern complete all as specified and as directed. |
| 161 | Supply only of plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 162 | Supply only PVC (SWR) WCconnector with lip ring complete all as specified and as directed. |
| 163 | PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 164 | Vitreous china counter top wash basin, including waste fittings of brass chromium plated 32mmexcluding taps, waste pipe butincluding fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixingas in repairs complete all as specified and as directed. Make: Prayag Cat No 4793 or equivalent makes listed here-in-after |
| 165 | Note:- |
| 166 | (a) Pillar tapsas required shall be measured and paid for under supply only separately. |
| 167 | (b) Supply only waste pipes as required shall be measured and paid for separately. |
| 168 | Supply only pillar taps, chromium plated, fancy type screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of bore of pipe 15mm complete all as specified and as directed. |
| 169 | Bevelled edged looking mirror of select quality glass, size 600mm x 450mm, 6mm thick, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed to walls as in repairs complete all as specified and as directed. |
| 170 | Granite (of any type) work, of thickness 18mm to 20mm, (table rubbed and polished) in wash basin platforms, cooking platforms, steps, jambs, pillars, windows and the like set in cement mortar 1:4, 20mm thick, including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stonecompleteall as specified and as directed. |
| 171 | Preparing newly plastered surfaces of wall, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint over wall care putty 3mm thick,complete all as specified and as directed |
| 172 | Complete removal of existing treatment from wall surfaces, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint over wall care putty 3mm thick,complete all as specified and as directed |
| 173 | Vitreous china urinal, half stall type, white (excluding waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe fixed as in repairs complete all as specified and as directed. |
| 174 | Note:- |
| 175 | (a) Flushing cistern, flush pipe, waste fitting as required shall be measured and paid for under supply only separately. |
| 176 | (b) Supply and waste pipes as required shall be measured and paid for separately. |
| 177 | Supply only waste coupling of PTMT (half or full threaded) suitable for urinalsfixed of bore of pipe 32mm (Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 178 | Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and as directed. |
| 179 | Stainless steel sink with drainage board, 1mm thick, for kitchen, with plugs, waste pipe, waste fittings, washers, including bedding in cement mortar 1:4 on dwarf walls or fixing on and including cantilever cast iron brackets, connecting union to pipe etc., overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm as in repairs complete all as specified and as directed. |
| 180 | Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete complete all as specified and as directed. |
| 181 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete of Fe 410 -W (Gde-E- 250) quality-A, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 182 | SCH \"A\" PART-II (INTERNAL ELECTRIFICATION) |
| 183 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, etc., and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 184 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 25 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep,concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., including taking down the existing unserviceable point wiring complete all as specified and as directedfor one light point controlled by one switch. |
| 185 | Note:- |
| 186 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 187 | All as per BOQ SL No.164 here-in-before but for one exhaust fan/wall mounting fan point controlled by one switch. |
| 188 | Note:- |
| 189 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 190 | All as per BOQ SL No.164 here-in-before but for one ceiling fan point controlled by one switch and regulator |
| 191 | Note:- |
| 192 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 193 | All as per BOQ SL No.164 here-in-before but for one bell/buzzer point controlled by one bell push |
| 194 | Note:- |
| 195 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 196 | All as per BOQ SL No.164 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches. |
| 197 | Note:- |
| 198 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 199 | All as per BOQ SL No.164 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board. |
| 200 | Note:- |
| 201 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 202 | All as per BOQ SL No.164 here-in-before but for point wiring with two 4 sqmm single core copper conductor multistranded cable and one 4 sqmm PVC insulated single coremultistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. |
| 203 | Note:- |
| 204 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 205 | Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed. |
| 206 | Bell p[ush, flush type single pole, one way, 5 Ampscomplete all as specified and as directed. |
| 207 | Switch piano, flush type single pole, one way, 5 Ampscomplete all as specified and as directed. |
| 208 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed. |
| 209 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal typecomplete all as specified and as directed. |
| 210 | Stepped type electronic fan regulator, 300 W, flush type, fixed on existing laminated sheet complete as specified and as directed. |
| 211 | MCB 5-32 Amps, SP, 230 Volts, 50 Hz, AC supply, \"B\" curve, with breakingcapacity of 10 kAcomplete all as specified and as directed. |
| 212 | MCB 40 Amps, SPN, 230 Volts, 50 Hz, AC supply, \"B\" curve, with breakingcapacity of 10 kAcomplete all as specified and as directed. |
| 213 | Bell, ding dong type, AC, 230 Volts, single pole complete all as specified and as directed. |
| 214 | Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, 240 V as in repairs complete all as specified and as directed. |
| 215 | LED batten fitting 20 W, 230V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. |
| 216 | Note:- |
| 217 | (a) Makeshall be Havells Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivalent of makes as listed here-in-after. |
| 218 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 219 | LED batten fitting 10 W, 230V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. |
| 220 | Note:- |
| 221 | (a) Makeshall be Havells Cat No. LUMILINEPLUSBS10WLED865SPCSS or equivalent of makes as listed here-in-after. |
| 222 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 223 | LED batten bulk head fitting 10 W, 230V, extruded aluminium housing provided for easy heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories suitable for operation on AC, single phase 220/230 Volts, 50 Hz supply including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. |
| 224 | Note:- |
| 225 | (a) Makeshall be C & S Cat No. SIRUS/10W LTB10WLED or equivalent of makes as listed here-in-after. |
| 226 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 227 | LED building security light fitting 20W made up of pressure die cast housing toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete, prewired and connecting up with suitable twin core copper wire including provision of necessary GI bracket light grade 25mm bore of pipe 1.5 m long bent to shape required with necessary clamps including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 228 | Note:- |
| 229 | (a) Makeshall be C & S Cat No. indus-i/20WCat No LTESSI20WLED or equivalent of makes as listed here-in-after. |
| 230 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 231 | LED edglit slim panel ceiling light 2x2 environmental friendly new generation aesthetically designed ultra modern recess mounting with extruded aluminium housing and diffuser LED panel suitable for armstrong/grid ceiling complete for low ceiling application 36 Watts LED (2\"X2\") complete with electronic driver suitable for operation on AC, single phase 220/230 Volts, 50 Hz supply including provision of twin core 2.5 sqmm copper conductor PVC insulated, 1100 volts complete all as specified and as directed. |
| 232 | Note:- |
| 233 | (a) Makeshall be Crompton Cat No CCR-127-36-57-SL-NWH or equivalent of makes as listed here-in-after. |
| 234 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 235 | LED ceiling light fitting 30 Watt, CRCA powder coating housing with anti-glare diffuser, deep back lit type surface mounting LED luminaire (2\"X2\") complete with electronic driver suitable for operation on Ac, single phase, 220/230 Volts, 50 Hz supply including provision of twin core 2.5sqmm copper conductor PVC insulated, 1100 volts grade cable not more than 5m long and connecting up ceiling rose and fittings and testing complete all as specified and as directed |
| 236 | Note:- |
| 237 | (a) Makeshall be C & S CYGNUS-CS/30/2X2/WCat No LTCSP30WLED2X2 or equivalent of makes as listed here-in-after. |
| 238 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 239 | LED energy saving suspended architectural LED luminaire capacity 36W and provides soft light and glare free symmetrical illumination (with continuous mounting end cap), IP65 with high efficiency integrated electronic driver complete including connection from ceiling rose to light fitting with suitable size cable with flexible pipe complete all aspecified and as directed. |
| 240 | Note:- |
| 241 | (a) Makeshall be Luker Cat No LPL70501M or equivalent of makes as listed here-in-after. |
| 242 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 243 | Rigid non metallic PVC conduit of 25mm dia including necessary fittings concealed in walls and fixed with suitable clamps on ceiling/roof trusses etc., complete all as directed. |
| 244 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmFRLSH conforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable FRLSH (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly including taking down existing unserviceable sub main wiring complete all as specified and as directed. |
| 245 | Note:- |
| 246 | (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length. |
| 247 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemedto be included in the item rates quoted for sub-main wiring / circuit wiring. |
| 248 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmmFRLSH conforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith two run 10 sqmm PVC insulated single core multistrandedcopper conductorcable FRLSH (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly including taking down existing unserviceable sub main wiring complete all as specified and as directed. |
| 249 | Note:- |
| 250 | (a) Four runs of 10 sqmm cable and two run of 10 sqmm cable and one run of conduit will be measured as one length. |
| 251 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemedto be included in the item rates quoted for sub-main wiring / circuit wiring. |
| 252 | Taking down MCB DB including inner components and provision of MCB DB SPN 8 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. |
| 253 | Taking down MCB DB including inner components and provision of MCB DB SPN 4 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. |
| 254 | Loadline MCB DB TPN 4 way, verticle, double door, powder coated, 415 Volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for fixing MCCB 100 Amps 4 pole as incomer and SP MCBs 40/63 Amps as outgoing with tinned copper bar, neutral link, earth link and connecting up complete allas specified and as directed. Make: Havells Cat No DHDLVDRWGOF004 or or equivalent makes listed here-in-afterNote: Incoming MCCB and outgoing MCBs shall be measured and paid seperately. |
| 255 | MCCB 100 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version)complete allas specified and as directed. |
| 256 | Taking down unserviceable ceiling fan and refixing in position duly rectified the defects, renewal of ball bearing, oiling/greasing/winding and testing for proper functioning including one coat of painting and writing MES No complete all as directed. |
| 257 | Taking down unserviceable exhaust fan and refixing in position duly rectified the defects, renewal of ball bearing, oiling/greasing/winding and testing for proper functioning including one coat of painting and writing MES No complete all as directed. |
| 258 | Exhaustfan, heavy duty, 250mm sweep, with louvers, metal body conforming to IS-2312-1967, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 259 | Wall mounting fan, 450mm sweep, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements and writing MES No. 20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 260 | Supply, installation, testing and commissioning of storage type water heater electric 25 litres capacity andconnecting up complete all as specified and as directed. |
| 261 | Note:- |
| 262 | Makeshall beHavells Cat No. GHWENZTWG025 or equivalent of makes as listed here-in-after. |
| 263 | Galvanised steel wire 4mm dia in earth continuity conductor or main earthing lead fixed all as directed |
| 264 | Provision of XLPE insulated, armoured,heavy duty electric cable with aluminium conductor, 25 sqmm, 4 core,1100 volts grade,in trenches / drawn through pipe / fixed on walls/ bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipmentscomplete all as specified and as directed. |
| 265 | Dry river sand laid to required width of trench at bottom and top forcable cushioning all as specified and as directed. |
| 266 | Note:- |
| 267 | Punned thickness only shall be measured. |
| 268 | Common burnt bricks sub class \"B\" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection complete all as specified and as directed. |
| 269 | Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches/ under floor / / under roads / crossings etc., ofbore of pipe 50mm for cable protection complete all as specified and as directed. |
| 270 | Taking out existing earthing materials and provision of Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed. |
| 271 | Supply, install, testing and commissioning of split AC, wall mountedhi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2,0TR complete all as specified and as directed. |
| 272 | Note:- |
| 273 | The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. |
| 274 | Supply, install, testing and commissioning of split AC, wall mountedhi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and as directed. |
| 275 | Note:- |
| 276 | The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. |
| 277 | Supply, install, testing and commissioning of split AC, inverter typew with minimum 3 star ratingof capacity 1.5 TR BEE including supporting frame work for out door unit complete all as specified and as directed. |
| 278 | Note:- |
| 279 | The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. |
| 280 | Supply, fix, testing and commissioning of automatic boost / buck transformer for low and high voltage correction, capacity of 5 kVA, complete with voltmeter and designed for an input voltage of 170 Volts to 250 Volts and a stabilised output voltage of 230 Volts with accuracy of + 2.5 % suitable to operate under 50 Hz, single phase air cooled wall mounting type complete all as specified and as directed. |
| 281 | Note:- |
| 282 | The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. |
| 283 | Supply, fix, testing and commissioning of automatic boost / buck transformer for low and high voltage correction, capacity of 4 kVA, complete with voltmeter and designed for an input voltage of 170 Volts to 250 Volts and a stabilised output voltage of 230 Volts with accuracy of + 2.5 % suitable to operate under 50 Hz, single phase air cooled wall mounting type complete all as specified and as directed. |
| 284 | Note:- |
| 285 | The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. |
| 286 | Digital timer switch micro controller based technology with LCD display suitable for split AC 1.5 Ton with auto/Manual facility and 1 to 24 hours programmable timers with all connected accessories and suitable wiring between AC to timer switch complete all as directed. |
| 287 | Copper tubing set 1/4\" and 1/2\" suitable for Split AC including PUF insulation and connected accessories complete all as directed. |
| 288 | Sensor glass door with frameless glass of size 3.49m X 2.4Mdivided into four parts, two both side fixed and centre two parts movement frequently with microprocessor digital controller and digital display including necessary fittings consumables complete all as directed. |