YMCA University of Science and Technology has published Supply Order Of Research Lab Items For Chemistry Dept. Supply Order Of Research Lab Items For Chemistry Dept. , Lab Equipments , Analytical Balance Specification: Capacity: 220 G With A Precision Of ±0.1 Mg, Internal Calibration Make: Shimadzu Or Sarto. Submission Date for this Tender is 04-10-2021. Tanks and Cylinders Tenders in JCBose University of Sci. and Tech. YMCA FBD Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Sep-2021 | Time extend | Date | 04-10-2021 |
Sl. No. | Item Description |
1 | Lab Equipments |
2 | Analytical Balance Specification: Capacity: 220 G with a Precision of ±0.1 mg, Internal Calibration Make: Shimadzu or Sartorius or Matller Toledo |
3 | Fluorescence CuvettesSpecification: Suprasil® quratz material, Spectral range 200-2,500 nm, Pathlength 10x10mm, chamber volume 3,500µL, 4 Polished windows, PTFE Stoppered Make: Hellma or Firely Sci or Supelco |
4 | Semi Micro Fluorescence CuvettesSpecification: Suprasil® quratz material, Spectral range 200-2,500 nm, Pathlength 10x2mm, chamber volume 700µL, 4 Polished windows, PTFE Stoppered Make: Hellma or Firely Sci or Supelco |
5 | Micro-Pipettes (0.5-10ul)Specification: Inaccurancy (µL) ±0.075, ±0.100, ±0.80, ±1.2, ±3.0, ±6.0, 200 no. suitable tips should be provided with pipettes,Make: Eppendorf or Thermofisher or Finnpipett/Ossila |
6 | Micro-Pipettes (10-100ul) Specification: Inaccurancy (µL) ±0.075, ±0.100, ±0.80, ±1.2, ±3.0, ±6.0, 200 no. suitable tips should be provided with pipettes, Make: Eppendorf or Thermofisher or Finnpipett or Ossila |
7 | Micro-Pipettes (20-200ul) Specification: Inaccurancy (µL) ±0.075, ±0.100, ±0.80, ±1.2, ±3.0, ±6.0, 200 no. suitable tips should be provided with pipettes, Make: Eppendorf or Thermofisher or Finnpipett or Ossila |
8 | Micro-Pipettes (100-1000ul) Specification: Inaccurancy (µL) ±0.075, ±0.100, ±0.80, ±1.2, ±3.0, ±6.0, 200 no. suitable tips should be provided with pipettes, Make: Eppendorf or Thermofisher or Finnpipett or Ossila |
9 | Micro-Pipettes(500-5000ul)Specification: Inaccurancy (µL) ±0.075, ±0.100, ±0.80, ±1.2, ±3.0, ±6.0, 200 no. suitable tips should be provided with pipettes, Make: Eppendorf or Thermofisher or Finnpipett or Ossila |
10 | Nitrogen Gas Cylinder with Regulator Specification: 47 Litre, with explosive certificate, working/Test Pressure: 250 Bar |