Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To Led Street Light And Other Work At Itarana Alwar Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To

Tender Notice

29083814
Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To Led Street Light And Other Work At Itarana Alwar Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To
Indian
Rajasthan
03-09-2021
25-09-2021
27-09-2021

Tender Details

Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To Led Street Light And Other Work At Itarana Alwar Spl Repair Of Coversion Of Lt Oh Lines To Lt Ug Cables And Connected Service And Convert Hpsv Light To Led Street Light And Other Work At Itarana Alwar

Key Value

Document Fees
INR 500 /-
EMD
INR 83500.00 /-
Tender Value
INR 41.64 Lakhs /-

BOQ Items

Name of Work : SPL REPAIR OF COVERSION OF LT OH LINES TO LT UG CABLES AND CONNECTED SERVICE AND CONVERT HPSV LIGHT TO LED STREET LIGHT AND OTHER WORK AT ITARANA ALWAR
Sl. No. Item Description
1Taking down old unserserviceable ACSR Conductor and GI wire of any size from LT Poles and removing from site complete all as specified and directed..
2Taking down old unserserviceable GI Earth wire/Guard wire etc.of any size from LT Poles and removing from site complete all as specified and directed.
3Dismantling and taking down of old unserviceable pin type/ shackle type insulators and from any height of electric pole, complete all as specified and directed.
4Taking down old unserviceable cross -arms/Clamps/nut bolts and Angle section etc from LT Pole any size, complete all as specified and directed.
5Dismantling and taking down old unserserviceable stay assembly from LT Poles and removing from site complete all as directed.
6Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified.
7Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminiumconductor of size 185 Sqmm 3.5 Core cable laid in trenches/pasing through pipe under road crossing etc all as specified and directed.
8All as per item No 7.00 but size 120 Sqmm 3.5 Core.
9All as per item No 7.00 but size 95 Sqmm 3.5 Core.
10All as per item No 7.00 but size 16 Sqmm 4 Core.
11All as per item No 7.00 but size 25 Sqmm 2 Core.
12All as per item No 7.00 but size 16 Sqmm 2 Core.
13Excavation in trenches n. exc. 1.5Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting out soft/loose soil.
14M&L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required covercomplete all as specified and directed. Note :- thickness after punning shall be considered for payment.
15M&L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
16Returning, filling in including spreading levelling , watering and well ramming in layers not exc. 25 cm in any type soil
17Removing of surplus excavated soil to a distance not exc. 50m and depositing where directed at a levelnot exc 1.5 Mtr above the starting point.
18Boring of holes under road,pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure.
19M&L Galvanized iron tubing, 50 mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete.
20M&L for PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in coping/pedestal of polesincluding providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
21Supply & errecting Cable path indicators for LT Cable made of CI plate fixed on MS angle iron size 25x25x5mm and 60 Cm long. and fixing in ground 30 Cm below ground level in PCC 1:3:6 type B-1 using 40mm grade stone aggregate of size 30x30x30cm . Cable path indicators shall be provided at distance of every 30 meters and at cable joints and turning of all cables and incorporated LT 1100 Volts on it.including PCC & earth work complete all as specified and directed.
22Fixing only retrived machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15650-2008 of 60mm thickness, M-35 grade with grey cement and no pigment except tiles, including taking down and 25cm thick sand cushioning complete all as specified and directed.(Note:-Sand cushion will be measured and paid separately).
23Supply and fixing of PVC insulated and round sheathed copper conductor cable 2.5 sqmm 3 core through and including steel conduit from street light fitting to junction box and making necessary connection both at junction box and street light fittings and fixing on pole with 2 Nos MS flat 25x3mm clamp including nut bolts complete all as directed.
24Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having bus bar chamber with insulated Aluminium bus bar four wire system, colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 3.2 mmCRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6 mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:-
25INCOMING (i)Thermal magnetic MCCB 4 pole,200 Amps 25 KA -01 No (ii)Aluminium bus bar 400 Amps with insulator-04 Nos (iii) Digital Voltmeter inbuilt selector switch, three phase Class 1= 01 No. (iv)Digital Ammeter square dial CT operated 96mmx96mm, three phase Class 1= 01 No (v)Instrument control fuses and indication lamp – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,160 Amps 25 KA -01 No (ii) MCB SP, 32 Amps 10 KA, "C" Curve -03 Nos+ (Space for one No MCB)
26All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i)Thermal magnetic MCCB 4 pole,160 Amps 25 KA -01 No (ii)Aluminium bus bar 250 Amps with insulator-04 Nos (iii)Instrument control fuses and indication lamp – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,125 Amps 25 KA -01 No (ii) MCB SP, 32 Amps 10 KA, "C" Curve -03 Nos+ (Space for one No MCB)
27All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i)Thermal magnetic MCCB 4 pole,125 Amps 25 KA -01 No (ii)Aluminium bus bar 200 Amps with insulator-04 Nos (iii)Instrument control fuses and indication lamp – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,100 Amps 25 KA -01 No (ii) Thermal magnetic MCCB 3 pole,63 Amps 25 KA -01 No (iii) MCB SP, 32 Amps 10 KA, "C" Curve -01 No+ (Space for one No MCB)
28All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i) Thermal magnetic MCCB 4 pole,100 Amps 25 KA -01 No (ii)Aluminium bus bar 200 Amps with insulator-04 Nos (iii)Instrument control fuses and indication lamp – one set OUTGOING (i)Thermal magnetic MCCB 3 pole,63 Amps 25 KA -01 No (ii) MCB SP, 32 Amps 10 KA, "C" Curve -03 Nos+ (Space for one No MCB)
29All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i) Thermal magnetic MCCB 4 pole,63 Amps 25 KA -01 No (ii)Aluminium bus bar 100 Amps with insulator-04 Nos (iii)Instrument control fuses and indication lamp – one set OUTGOING (i)MCB SP, 32 Amps 10 KA, "C" Curve -04 Nos+ (Space for one No MCB)
30All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i)Thermal magnetic MCCB 4 pole,320 Amps 36 KA -01 No (ii)Aluminium bus bar 480 Amps with insulator-04 Nos (iii) Digital Voltmeter inbuilt selector switch, three phase Class 1= 01 No. (iv)Digital Ammeter square dial CT operated 96mmx96mm, three phase Class 1= 01 No (v)Instrument control fuses and indication lamp – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,160 Amps 25 KA -02 Nos (ii) MCB SP, 32 Amps 10 KA, "C" Curve -02 Nos+ (Space for one No MCB)
31All as per Item No 24.00 & 24.01 but the following accessories:- INCOMING (i)Thermal magnetic MCCB 4 pole, 100 Amps 25 KA -01 No (ii)Aluminium bus bar 200 Amps with insulator-04 Nos (iii)Instrument control fuses and indication lamp – one set OUTGOING (i) MCB SP, 32 Amps 10 KA, "C" Curve -06 Nos+ (Space for one No MCB)
32S&F in repair for pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp three phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance freesize 300x200x 100 mmfixing on pole with MS flat 25x3mm clamp including nut boltsfront openable all as specified and directed.
33S&F in repair for pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance freesize 300x200x100 mmfixing on pole with MS flat 25x3mm clamp including nut boltsfront openable all as specified and directed.
34S&F of Automatic street light switch using Infrared Sensor based three phase Nature Switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.3 Nos contactors each of 25 Amp and Incoming-outgoing MCBs single pole (3 Nos each) rating 25 Amp and Auto-Manual(sensor By pass) selection option should be enclosed in a pole/wall mountable enclosure made of Rust proof , Electric shock proof, Termite proof and FR grade SMC junction box conforming to IP54.Model : SWADEEP-02EC complete all as directed by Engr-in-Charge
35M&L for earthing complete as per electric plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60x60cmx6.3mm thick burried directly in ground ( earth pit not less thanb 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised strip 25 x 4 mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel . Earthing strip shall be protected by galvanised iron pipe 40 mm bore light grade and connected to continous earth lead on pole/test point, Watering pipe shall be 20 mm bore GI medium grade. The unit rate quoted for earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover complete all as specified and directed.
36Dismantling and disconnect all electric cable from existing LT panel/ APFC panel and taking downLT panel/ APFC panel for shifting to other location within 100 Meter inside cantt area, and including grouting of panel, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete, and re-connection all electric cable with lugs to LT panel/ APFC panel complete all as directed by Eng-in-Charge.
37Supply, installation, testing and commissioning of LED Street Light Foster 45W Intelligent Dusk Dawn Sensor based LED Street Light for automatic switch on and off based on daylight lux levels. Dusk Dawn Sensor mounted on LED PCB, Cast aluminium housing, cleartoughened glass diffuser,IP65, 10 KV SPD, >100 lm/watt and wired with accessories complete all as specified.
38S&F street light bracket made to shape at required angle made out of 40mm dia ( light grade ) GI tubing of length not less than 1.5m long fixing on wall/pole suitable for holding street light fittings including mild steel flate iron 50 x 6 mm clamp 02 Nos with bolts, nuts and washer complete all as directed by Engr-in-Charge.
39S&F 4 sqmm PVC insulated & sheathed cable twin core aluminium conductor cable from street light feeder/junction box to street light fittings complete all as directed by Engr-in-Charge.
40Supply, installation & testing Geyser (water storage type) of capacity 25 litre, Star rated suitable for 240V, SP, 50 Hz AC supply fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts &washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original all as per manufacturer’s instructions & as directed. Make :- Bajaj / Crompton Greaves / Usha Lexus / Venus / Racold.
41M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 2.5 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling complete all as specified and directed. Note:-02 runs of 4 sqmm size, 01 run of 2.5 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
42S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
43S&F galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
44S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
45S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
46S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
47S&F MCB 25 Amps, single pole, 230 Volts complete all as specified and directed.