Spad ( Chlorophyll Analysis ) Spad ( Chlorophyll Analysis ) , Spad ( Chlorophyll Analysis ) , Technical Specifications Type: Handheld Meter For Measuring Chlorophyll Measurement Sample: Plant Leaves Measurement Area: 2Mm × 3Mm Medium Sample Thick
Tender Overview
Project Description
Spad ( Chlorophyll Analysis ) Spad ( Chlorophyll Analysis ) , Spad ( Chlorophyll Analysis ) , Technical Specifications Type: Handheld Meter For Measuring Chlorophyll Measurement Sample: Plant Leaves Measurement Area: 2Mm × 3Mm Medium Sample Thickness: 1.2 Mm Insertion Depth: 12 Mm Maximum; Depth Stop Adjustable To Depths Between O And 6 Mm Light Sources: 2 Leds ( Light-Emitting Diodes ) Receptor: 1 Spd ( Silicon Photodiode ) Display: Lcd Panel Showing 4 Digit Measurement Value ( -9.9 To 199.9 ) And 2 Digit Data Number Data Memory: Space For 30 Data Controls: Power Switch: Switches Power On And Off Average Key: Calculates The Average Of All Data In Memory All Data Clear Key: Deletes All Data In Memory Data Recall Key: Recalls Data Graphically For Previous Data Number 1 Data Delete Key: Deletes Displayed Data Measurements Automatically Taken When Measuring Head Is Closed Power Source: 2 Aa-Size 1.5V Alkaline-Manganese Battery Life: More Than 20, 000 Measurements Per Set Of 2 Alkaline-Manganese Batteries Minimum Interval Between Measurements: Less Than 2 Seconds Accuracy: Within ± 1 Spad Unit ( At Room Temperature, Spad Value Between 0 And 50.0 ) ; Spad Valuesof Greater Than 50.0 May Be Less Accurate And Will Cause * To Appear Repeatability: Within ± 0.3 Spad Units ( Spad Value Between 0 And 50.0 ) Reproducibility: Within ± 0.5 Spad Units ( Spad Value Between 0 And 50.0 ) Temperature Drift: Less Than 0.4 Spad Units 0C Operating Condition: 0 To 500C ( 32 To 1220F ) Relative Humidity Less Than 85% At 350C With No Condensation Other: Buzzer ( Single Beep For Measurement Complete, Series Of Beeps For Error ) ; Function For Inputtingcompensation Value Dimension ( L × W × D ) : 164 × 78 × 49 Mm Weight: 200G ( Without Batteries ) Standard Accessories: Sliding Depth Slope; Carrying Strap; Soft Case; 2 Aa-Size Batteries Reading Checker *Spad Values Are Values Defined By Konica Minolta Which Indicate The Relative Amount Of Chlorophyll Present In Plant Leaves. Specification Subject To Change Without Notice
BOQ
| Sl. No. | Item Description |
| 1 | SPAD (Chlorophyll Analysis) |
| 2 | Technical SpecificationsType: Handheld meter for measuring chlorophyllMeasurement sample: Plant leavesMeasurement area: 2mm × 3mmMedium sample thickness: 1.2 mmInsertion depth: 12 mm maximum; depth stop adjustable to depths between o and 6 mmLight sources: 2 LEDs (Light-emitting diodes)Receptor: 1 SPD (Silicon photodiode)Display: LCD panel showing 4 digit measurement value (-9.9 to 199.9) and 2 digit data numberData memory: Space for 30 dataControls: Power switch: Switches power on and offAverage key: calculates the average of all data in memoryAll data clear key: deletes all data in memory Data recall key: recalls data graphically for previous data number 1 data delete key: deletes displayed data Measurements automatically taken when measuring head is closedPower source: 2 AA-size 1.5v alkaline-manganeseBattery life: more than 20,000 measurements per set of 2 alkaline-manganese batteriesMinimum interval between measurements: less than 2 secondsAccuracy: within ± 1 SPAD unit (at room temperature, SPAD value between 0 and 50.0); SPAD valuesof greater than 50.0 may be less accurate and will cause * to appearRepeatability: within ± 0.3 SPAD units (SPAD value between 0 and 50.0)Reproducibility: within ± 0.5 SPAD units (SPAD value between 0 and 50.0)Temperature drift: less than 0.4 SPAD units 0COperating condition: 0 to 500C (32 to 1220F) relative humidity less than 85% at 350C with no condensationOther: buzzer (Single beep for measurement complete, series of beeps for error); function for Inputtingcompensation valueDimension (L × W × D): 164 × 78 × 49 MMWeight: 200g (without batteries)Standard accessories: sliding depth slope; carrying strap; soft case; 2 AA-size batteries Reading checker*SPAD values are values defined by Konica Minolta which indicate the relative amount of chlorophyll present in plant leaves. Specification subject to change without notice |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed