Extension And Remodelling Of Various Dia Pvc Pipe Line Including Other Allied Works At Different Locations Under Hrishyamukh R.D Block During The Year 2021-22. Extension And Remodelling Of Various Dia Pvc Pipe Line Including Other Allied Works At Differen
Tender Overview
Project Description
Extension And Remodelling Of Various Dia Pvc Pipe Line Including Other Allied Works At Different Locations Under Hrishyamukh R.D Block During The Year 2021-22. Extension And Remodelling Of Various Dia Pvc Pipe Line Including Other Allied Works At Different Locations Under Hrishyamukh R.D Block During The Year 2021-22.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating trenches of required width for pipes, cables etc.including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A. For UPVC pipes in new worka. In all kinds of soil |
| 2 | i. For pipes not exceeding 90 mm dia |
| 3 | ii. For pipesexceeding 90 mm dia but not exceeding 300 mm dia |
| 4 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cementconforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 5 | i. 90 mm OD |
| 6 | ii. 110 mm OD |
| 7 | iii. 140 mm OD |
| 8 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. PN 1.6 |
| 9 | i. 80 mm dia. |
| 10 | ii. 100 mm dia |
| 11 | iii. 125 mm dia |
| 12 | iv. 150 mm dia. |
| 13 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge.A) With 1st class bricks. |
| 14 | Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. |
| 15 | i. 90 mm OD |
| 16 | ii. 110 mm OD |
| 17 | iii. 140 mm OD |
| 18 | Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc.complete as per specification & direction of the Engineer-incharge. |
| 19 | i. 90 mm OD |
| 20 | ii. 110 mm OD |
| 21 | iii. 140 mm OD |
| 22 | Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth includingconsolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-incharge. |
| 23 | i. 90 mm OD. |
| 24 | ii. 110 mm OD. |
| 25 | iii. 140 mm OD. |
| 26 | Dismantling old C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per CPWD specification and direction of the Engineer - in - charge. |
| 27 | i. 80 mm dia |
| 28 | ii. 100 mm dia |
| 29 | iii. 125 mm dia |
| 30 | iv. 150 mm dia |
| 31 | Disinfecting C.I. / D.I. water mains by flushing with water containing bleaching powder at 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the DWS laboratory as per IS:2800 and direction of the Engineer - in - charge. |
| 32 | i. 80 mm dia |
| 33 | ii. 100 mm dia |
| 34 | iii. 125 mm dia |
| 35 | iv. 150 mm dia |
| 36 | Charges for cutting D.I. pipe with Mechanical cutter as per CPWD specification and direction of the Engineer - in -charge. |
| 37 | i. 80 mm dia |
| 38 | ii. 100 mm dia |
| 39 | iii. 125 mm dia |
| 40 | iv. 150 mm dia |
| 41 | Providing and fixing C.I. double action air valve of approved quality with bolts, nuts, rubber insertions etc. complete as per CPWD specification and direction of the Engineer - in -charge. ( The tail pieces, tapers etc if required will be paid separately ). |
| 42 | i. 80 mm dia |
| 43 | ii. 100 mm dia |
| 44 | iii. 125 mm dia |
| 45 | iv. 150 mm dia |
| 46 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.A. by manual means |
| 47 | Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead as per CPWD specification and direction of the Engineer - in - charge. |
| 48 | i. 100 mm dia |
| 49 | ii.125 mm dia |
| 50 | iii.150 mm dia. |
| 51 | Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 52 | i. 90 mm dia |
| 53 | ii. 110 mm dia |
| 54 | iii. 140 mm dia |
| 55 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cementconforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 56 | i. 90 mm dia |
| 57 | ii. 110 mm dia |
| 58 | iii. 140 mm dia |
| 59 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in charge |
| 60 | i. 90 mm dia |
| 61 | ii. 110 mm dia |
| 62 | iii. 140 mm dia |
| 63 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cementconforming to IS :14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 64 | a. 90 x 90 mm dia |
| 65 | b. 110 x 110 mm dia |
| 66 | c. 140 x 140 mm dia |
| 67 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cementconforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 68 | i. 110x 90 mm dia |
| 69 | ii.140 x 110 mm dia |
| 70 | iii.140 x 90 mm dia |
| 71 | Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 72 | i. 90 mm dia |
| 73 | ii. 110 mm dia |
| 74 | iii. 140 mm dia |
| 75 | Providing and fixing of G.I tyton collar in/c MS flange (two part) with rubber gasket fitted with MS flat at both ends including nuts,bolts,washer and Painting with anti-corrosive black bit mastic point etc. complete as direction of the Engineer - in - charge. |
| 76 | i. 100 mm dia. |
| 77 | ii. 125 mm dia |
| 78 | iii. 150 mm dia |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender