Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ) At Subroto Park Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ), GE (AF) SUBROTO PARK-Delhi

Military Engineer Services-MES has published Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ) At Subroto Park Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ). Submission Date for this Tender is 25-10-2021. Civil Work Tenders in GE (AF) SUBROTO PARK Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29052631
Corrigendum : Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ) At Subroto Park Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area )
Open Tender
Indian
Delhi
GE (AF) SUBROTO PARK
25-10-2021

Tender Details

Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ) At Subroto Park Reconstruction Of 13 Dus ( Demolished By Nhai For Construction Of T-Junction And Under Pass At Subroto Park Area ) At Subroto Park

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Sep-2021 DATE1 Date 14-10-2021
2 05-Oct-2021 AMNDT 02 Date 18-10-2021
3 06-Oct-2021 BOQ BOQ 18-10-2021
4 06-Oct-2021 OTHER1 Other 18-10-2021
5 06-Oct-2021 OTHER Other 18-10-2021
6 06-Oct-2021 OTHER3 Other 18-10-2021
7 08-Oct-2021 BOQ2 BOQ 18-10-2021
8 13-Oct-2021 DATE4 Date 18-10-2021
9 18-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-10-2021
10 20-Oct-2021 OTHER4 Other 25-10-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 654000.0 /-
Tender Value
INR 6.58 Crore /-

BOQ Items

Name of Work :RECONSTRUCTION OF 13 DU"s (DEMOLISHED BY NHAI FOR CONSTRUCTION OF T-JUNCTION AND UNDER PASS AT SUBROTO PARK AREA ) AT SUBROTO PARK.
Sl. No. Item Description
1SCHEDULE `A" PART - I (Building Works) is not prepriced by MES and prepriced rates indicates0.00 under column 5 signifies this fact only.
2Construction of Maj Gen Md Accn (Block of 04 Qtr, G+1 )complete all as specified, shown on drawings and as directed.
3Construction of Maj and Lt Col Md Accn (Block of 02 Qtr, G+1 )complete all as specified, shown on drawings and as directed.
4Construction of Maj and Lt Col Md Accn (Block of 01 Qtr, single storey)complete all as specified, shown on drawings and as directed.
5NOTE: Schedule ‘A’ Part IIto XI are Prepriced by MES.
6Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’Part II
7Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’Part III
8Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’Part IV
9Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’Part V
10Lump sum price worked out by the Contractor for “ROAD / PATH / CULVERT " as listed in Schedule ‘A’Part VI
11Lump sum price worked out by the Contractor for “AREA DRAINAGE ” as listed in Schedule ‘A’Part- VII
12Lump sum price worked out by the Contractor for“FENCING / GATE / COMPOUND WALL” as listed in Schedule ‘A’Part-VIII
13Lump sum price worked out by the Contractor for“RAIN WATER HARVESTING” as listed in Schedule ‘A’Part - IX
14Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’Part - X
15Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’Part XI
16SCHEDULE `A" PART - XIII MISC ITEMS(B/R & E/M)is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifie this fact only.
17INTERNAL ELECTRIFICATION
18S&F LED bulb, 09 watt, 230 volts retrofit typecomplete all as specified and as directed.
19S&F energy saving decorative box type batten light fitting 230 volts surface mounted complete with high efficiency PMMA diffusersoft glare free light LED tube light20watt, blue coloured end caps with all accessories, pre-wired,including providing flexible copper wire, three corecable PVC insulated sheathed complete all as specified and as directed.
20S&F LED sleek mirror light fitting 10 watt surface mounted provided with high output diffuser 2 ft long, 230 Volts complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core 0.50 sqmm PVC insulated anc overall heathed complete all as specified and directed by Engineer-in-Charge.
21Supply& Fixing S&F LED Square/Round Ceiling light fitting 6 watt provided with high output diffuser , 230 Volts complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and as directed.
22S&F decorative wall mounting Bed side fitting having flexible neck complete all as specified and as directed.
23S&F LED bulk Head fitting comprising pressure die cast housing,acrylic diffuser & frame, having IP-65 protection,energy efficient, 13.5 watts complete all as specified and as directed.
24S&F decorative LED wall light historical style,energy efficient ,230 Volts including Led lamp 9 wattscomplete all as specified and directed.
25S&F ceiling fan five star rated 1200 mm sweep complete with out fan regulator 230 volts (single phase) and provisioning of flexible copper cord three core PVC insulated & overall sheathed of size 0.50 Sqmm of required length from ceiling rose or connector to ceiling fan complete all as specified and as directed.
26S&F ventilating fan of size 230 mm sweep, 900 RPM ,230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC insulated & overall sheathed of size 0.50 sqmm from ceiling rose to exhaust fan complete all as specified and as directed.
27Supply and fixing MCCB distribution panel board TPN 6 way double door,415 Volts with 400 amps Rating bus bar inc meter module analog provision of Ammeter,voltmeter with selector switchcomplete all as specified and as directed.
28S&F MCB SP 6 to 32 Amps, C Curve type 10 KA breaking capacity 240 Voltscomplete all as specified and as directed.
29S&F MCB SPN 40 Amps to 63 Amps, C curve type 10 KA Breaking capacity 240 Volts complete all as specified and as directed.
3038 S&F MCB TPN 40 Amps to 63 Amps, C curve type 10 KA Breaking capacity 415 Volts complete. all as specified and as directed.
31Design, manufacturing, supplying and installing in correct aligned position making proper connections testing and commissioning of Energy Meter Panel (for accommodate of 2 Nos Energy Meters) suitable for 415 V, Three phase, 4 wire, 50 Hz power distributor system. The panel shall be indoor IP-42 rating, free standing, floor/wall mounted, sheet metal clad, cubical, dust and vermin proof type, compartmentalised design fabricated out of 2 mm CRCA sheet steel complete.Adequite size of incoming and outing going feeders cable alley proper locking arrangement, transparant glass for checking of reading,painting .earthing,numbering danger plate including necessary earth and PCC work for erection of of panel complete all as specified and as directed including thefollowings:-
32(i) Alluminium Bus Bars 4 Nos 200 Amps capacity complete (ii) Incomer MCCB 100 Amps,4 pole 25 KA -01 No (iii) MCB TPN 63 Amps,230 Volts "C" curve 10 KA capacity-02 Nos (iv) MCB SPN 10 Amps,230 Volts "C" curve 10 KA capacity-01 No (v) Internal wiring with 10 Sqmm copper stranded conductor. (vi) Volt meter 500 volt, Amp meter 0-100 Amps and indicator lamp complete. Note:- Rate for Energy meter will be measured and paid seperatey under respective item
33Design, manufacturing, supplying and installing in correct aligned position making proper connections testing and commissioning of Bus Bar Chamber 200 Amps ,415 Volts. Three phase, 4 wire, 50 Hz power distributor system having Bus Bar 4 Nos 200 Amps rating. It shall be indoor IP-42 rating, free standing, floor/wall mounted, sheet metal clad, cubical, dust and vermin proof type, design fabricated out of 2 mm CRCA sheet steel complete.Adequite size of incoming and outing going feeders cable alley proper locking arrangement, .painting .earthing,numbering danger plate including necessary cement work for fixing bus.bar chamber in walls complete all as specified and as directed.
34Supplying, installation, testing & commissioning of 3 Phase, 4 Wire, Dual Source, Pre-paid Energy Meters, BIS 15884 Marked in existing Meter Board / Floor Panels duly noting down the meter reading and meter reading register to be handed over to respective BSOs) with Pre Payment capacitive touch Key pad,Bluetooth based Digital having current range 10-60Amp, 415V, acucuracy class 1.0 along with Parallel home display split Untt, with inbuilt load control switch, containing provision forTOD & RTC, .inbuilt feature sense the DG Mode through PLSI, dual source registration with respect to
35Grid as well as DG supply (wireless, without DCU& Sim, no other extra equipent. required for dual sence, meter it self capable for dual senceing) and dynamic load allocation facility from Grid and DG, capable to define 4 tariff slabs, happy hour &"holiday definition all as specified and directed. That the manufacturer or their service provider shall furnish 10 (Ten) years replacement guarantee for prepaid meters installed under this contract.(Cost of connecting to existing system is deemed to be included in the rates quoted Make:- Secure, Model:- Liberty 370 or equivalent specification of other makes with prior approval of GE.
36M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead Glearth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvinised iron or steel and other end of the earth connected to panel and protected
37by Gl or steel pipe light grade 40 mm bore and water pipe 20mm bore Gl light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be Dre-cast of RCC (1:2:4) type B-i , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of Cl cover. complete all as specified and as directed.
38M&L for TV socket with cable grip Modular type,1 module complete all as specified and as directed.
39M&L for Telephone socket with shutter-twin RJ 11 Modular type,1 module complete all as specified and as directed.
40M&L for telecom switch board cables PVC insulated for indoor applications unarmoured 0.4 mm ATC, 4 pair complete all as specified and as directed.
41M&L CO-axial cables electronic grade solid anneated copper conductor, jelly field,alluminium foiled and aluminium wire braided RG 59(Foam) type for cable connection incl drawn into conduits complete all as specified and as directed.
42M&L for metallic telephone juction box 10 Pair, single door, powder coated IP-42 potection complete all as specified and as directed.
43EXTERNAL WATER SUPPLY
44M&L for construction of brick masonry valve pitof size 100cmx100cmx100cm ( internal dimensions of chamber, depth to be reconed from the top of PCC in foundation to top of MS cover) with mild steel sheet cover 3.15 mm thick including angle iron frame of size 40x40x6mm with locking & fixing arrangement duly painted with 2 coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in cement mortar 1:4 and all internal and external wall surfaces of pit shall be plastered with 15mm thick in cement mortar (1:4), necessary excavation and earthwork in any type of soil, returning filling in, disposal of surplus soil to a distance not exceeding 50 mtrs and including foundation concrete (1:4:8) type D-2 using 40mm graded stone aggregate, and cement concrete(1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping etc. complete all asspecified and as directed.
45EXTERNAL ELECTRIFICATION
46M&L for boring holes across the road / plinth / hard standing by trenchless technology method suitable for up to 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging road / plinth/ floor complete all as specified and as directed.
47Taking out old unserviceable under ground LT cable of any size from trenches / road / floor / pipe / along poles including taking out old bricks complete all as specified and as directed.
48S&F hot moulded FRP looping / junction box size 280mm x 200mmfor street light poles with locking arrangement and suitable connection for three phase incomming cable , three phase outgoing cable and single phase connection for light fitting incl controlled MCB sp-10 Amps - 01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather, vermin proof, dust and water proofcomplete with two Nos cables entry incl gland of standard size with suitable size mild steel clampto fix on polecomplete all as specified and as directed.
49Supply & fixing LED street light fitting 70 Watts aluminium dia cast housing with efficient heat dessipation design and green painted housing with UV treated coated having CRI > 70 and built in electronic driver with APFC and THD < 10%, PF > 95 and system luminious afficasy >100 Lumen per watt complete all as specified and as directed.
50Supply & fixing LED bolard type garden light fitting 9-12 Watts aluminium dia cast housing with efficient heat dessipation design and green painted housing with UV treated coated having CRI > 15 and built in electronic driver with APFC and THD < 10%, PF > 95 and system luminious afficasy >100 Lumen per watt complete all as specified and as directed.
51Supply & fixing LED type Post top light fitting 40 Watts aluminium dia cast housing with efficient heat dessipation design and green painted housing with UV treated coated having CRI > 15 and built in electronic driver with APFC and THD < 10%, PF > 95 and system luminious afficasy >100 Lumen per watt complete all as specified and as directed.
52Supplying, installing,testing and commissioning factory made tested, ( CPRI approved) LT panel box outdoor type platform mounted suitable for 415 Volts, 3 phase, 4 wire, 50 cycle AC supply having bus bar chamber with insulated copper bus bar 400 amp rating installed on porcelain insulators. The panel shall be dust and vermin proof IP 65 class protection made out of3.15 mm thick CRCA- MS sheet and 50 x 50 x 6 mm thick angle iron frame work and chanel for base, powder coated finish cubical type , machine pressed weather proof spray painted from inside and out side with approved paint front opening type with Appron for cable entering with double door shutters and locking arrengement including provision of lock with keys . Internal wiring with PVC insulated, stranded copper conductor FRLS cable IS-694 marked of adequate size. The scope of work including following accessories :-(i) Connection of input and outgoing cables and complete wiring of LT switch gears with pre insulated copper conductor of suitable size by using copper thimbles testing and commissining complete.INCOMING :- (a) MCCB 4 Pole, 415 V grade , 400 Amps 36 KA with electronic release, ICS = ICU - 01 No.(b) Voltmeter square type 96 x 96 mm, 0-500 V with selector switch-01 set (Digital type) (c) Ampear meter square type 96 x 96 mm, 400 Amps with suitable CT and selector switch-01 set (Digital type).(d)Indicating lamp neon/LED type - 01 set" of three.OUT GOING :- (a) MCCB63 Amp, 4 pole 16 KA adjustable type -06 Nos (01 No spare) (b) MCCB 250 Amps, 4 pole, 36 KA adjustable type -01 No for (for panel No 2). (c). Street light timer with all accessories ie. contactor,microprocessor based astronomical timer and MCB TPN 40 Amps, tway way switch for auto and manual mode, protection MCB for time etc including necessary electric connection - 01 Nos
53Supplying installing,testing and commissioning factory made tested (CPRI approved) LT panel box outdoor type platform mounted suitable for 415 Volts, 3 phase, 4 wire, 50 cycle AC supply having bus bar chamber with insulated copper bus bar 400 amp rating installed on porcelain insulators. The panel shall be dust and vermin proof IP 65 class protection made out of3.15 mm thick CRCA- MS sheet and 50 x 50 x 6 mm thick angle iron frame work and chanel for base, powder coated finish cubical type , machine pressed weather proof spray painted from inside and out side with approved paint front opening type with Appron for cable entering with double door shutters and locking arrengement including provision of lock with keys . Internal wiring with PVC insulated, stranded copper conductor FRLS cable IS-694 marked of adequate size.
54The scope of work including following accessories :-(i) Connection of input and outgoing cables and complete wiring of LT switch gears with pre insulated copper conductor of suitable size by using copper thimbles testing and commissining complete.INCOMING :- (a) MCCB 4 Pole, 415 V grade , 250 Amps 36 KA with electronic release, ICS = ICU - 01 No.(b) Voltmeter square type 96 x 96 mm, 0-500 V with selector switch-01 set (Digital type) (c) Ampear meter square type 96 x 96 mm, 300 Amps with suitable CT and selector switch-01 set (Digital type).(d)Indicating lamp neon/LED type - 01 set" of three.OUT GOING :- (a) MCCB63 Amp, 4 pole 16 KA adjustable type -05 Nos (01 No spare) (b) MCB 40 Amps, SPN 10 KA adjustable type -01 No for street light.
55Supply and laying of PVC insulated with copper conductor cable of size 2.5 Sqmm 3 core fixed in position from FRP looping box to street light fitting connector with fixing arrangement on steel tubular pole complete all as specified and as directed.
56Supply and fix MCB DB 2 way 230 volts SPN with DP MCB 10 Amps complete all as specified and as directed.
57RAIN WATER HARVESTING
58M&L for drilling 250mm dia hole by DTH cum rotary at any depth below ground level in any kind of rock/soil upto 100M depth incl disposal of surplus soil to a distance n exc 5o mtr away complete all as specified and as directed.
59Supply, lowering and jointing into bore hole 150mm dia PVC casing pipe perforated hole complete all as specified and as directed.
60Supply, lowering and jointing into bore hole 150mm dia PVC casing pipe complete all as specified and as directed.