}

As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai - 1 Dismantling Of Plain Or Corrugated Or Semi Corrugated Steel Sheeting As In Roof Covering Complete All As Specified And Dir, Chennai-Tamil Nadu

Military Engineer Services has published As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai - 1 Dismantling Of Plain Or Corrugated Or Semi Corrugated Steel Sheeting As In Roof Covering Complete All As Specified And Dir. Submission Date for this Tender is 16-09-2021. Rough Finishing Tools Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

29052526
Corrigendum : As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai - 1 Dismantling Of Plain Or Corrugated Or Semi Corrugated Steel Sheeting As In Roof Covering Complete All As Specified And Dir
Indian
Tamil Nadu
Chennai
16-09-2021

Tender Details

As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai As As To Vip Room At Meenambakkam Under Age ( I ) Navy Chennai - 1 Dismantling Of Plain Or Corrugated Or Semi Corrugated Steel Sheeting As In Roof Covering Complete All As Specified And Directed By Engineer In Charge. 2 S&F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By Engineer In Charge 3 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By Engineer In Charge 4 Dismantling Wall And Ceiling Boards ( Fibre, Pulb, Insulation Etc ) Or Insulation Boards Slabs / Blankets Any Thickness Including Cover Fillets Complete All As Specified And Directed By Engineer In Charge 5 M&L For Suspended False Ceiling Using E-Grid 2430, 180 Gsm ( Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600mm With Main Runner 38 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 8Mm Thick High Pressure Non Asbestos Fiber Cement Decorative Board ( E-Board Classic ) In A Grid Of Gi System Duly Suspended With 4 Mm Dia Gi Bar Hanger Fixed With Steel Dash Fasteners Or Iron Purline From The Roof Eith Adjustment Clip Providing Positions For Light Fixtures, Air Conditioning Diffuser And Ducts, Sprinkler, Smoke Detectors Etc. The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C / C. The Last Hanger At The End Of Each Main Runner Should Not Be Interlocked Between Main Runners @ 610Mm C / C, As To Form 600 Mm X 600 Mm Grid Complete All As Specified And Directed By Engineer In Charge 6 Taking Down Shutters Of Any Description N Exc 1 Sqm Each Leaf Complete All As Specified And Directed By Engineer In Charge 7 Taking Down Shutters Of Any Description Exc 1 Sqm N Exc 2 Sqm Each Leaf Complete All As Specified And Directed By Engineer In Charge 8 Taking Down Shutters Of Any Description Exc 1 Sqm N Exc 2 Sqm Each Leaf And Refixing In Same Opening Complete All As Specified And Directed By Engineer In Charge 9 Taking Down Wooden Chowkhats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Of Size Not Exceeding 1.50 Square Metre Each Including Cutting Holes In Brick Walls Of Appropriate Size For Insertion Of Cement Concrete Blocks For Hold Fasts Complete All As Specified And Directed By Engineer In Charge 10 All As Per Sl Item No. 09 Above But Size Exceeding 1.5 Square Metre And Not Exceeding 4 Square Metre Each Complete All As Specified And Directed By Engineer In Charge 11 S&F 30Mm Thick Flush Shutter Solid Core Construction With Block Board Core And Plywood Face Panels Commercial Type On Both Side Complete All As Specified And Directed By Engineer In Charge 12 S&F 2Nd Class Hard Wood Glazed And Skeleton Door Shutters 30Mm Thick Open Rebated And Prepared To Receive Glass, Guage Etc ( Without Sash Bars ) , Edge Of Framing Plain Chemfered Ro Rounded Fitted With Cut And Mitred Beds For Securing Glass Etc Size Of Members Of Shutters As Specified In Ssr Part I Section 8 Clasue 8.20 ( A ) Complete All As Specified And Directed By Engineer In Charge 13 S&F 2Nd Class Hard Wood Glazed And Skeleton Ventilator / Window 30Mm Thick Open Rebated And Prepared To Receive Glass, Guage Etc ( Without Sash Bars ) , Edge Of Framing Plain Chemfered Rounded Fitted With Cut And Mitred Beds For Securing Glass Etc Size Of Members Size Of Members Of Shutter As Specified In Ssr Part I Section 8 Clasue 8.20 ( B ) Complete All As Specified And Directed By Engineer In Charge 14 Demolition Of Un-Reinforced Cement Concrete In Ground Floor And Paving Not Exceeding 15 Cm Thick ( Below Or Above Ground Level ) Complete All As Specified And Directed By Engineer In Charge 15 M&L Cement Concrete ( 1:3:6 ) , Type C-1 Using 20Mm Graded Stone Aggregate As In Filling Of Steel Chowkhats And Holdfast Including Necessary Form Work Complete All As Specified And Directed By Engineer In Charge 16 S&F Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Of 5 Mm Plain Colour Pvc Sheet Reinforced With Mild Steel Square Tube Complete All As Specified In Clause 8B.3.1 And Shown On Page 150 Of Mes Schedule Part-Ii ( 2010 ) Complete All As Specified And Directed By Engineer In Charge 17 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails, Ms Frame Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Paneling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading And Jointed Together With Solvent Cement, S&Fing In The Frame At Site As Per Clause 8 B.2.1 Of Mes Schedule Part-Ii ( 2004 ) Complete All As Specified And Directed By Engineer In Charge 18 S&F Anodised Aluminium Powder Coated Any Colour As Approved For Ventilator Frame And Shutter , Half Fixed And Half Louvered Type Without Sash Bar , Incuding 4 Mm Thick Glass , Necessary Joining Cleats , Glazing Clips , Rubber Packing , Anodised Aluminium Snap Beading , Screws Etc And Section 1.5 Mm Thick Section Size Complete All As Specified And Directed By Engineer In Charge 19 S&F Anodised Aluminium Powder Coated Any Colour As Approved Window Shutters, Incl Window Frame With Three Track Sliding Type, Without Sash Bars Including Guide Rollers As Reqd Nos, Including 4Mm Thick Glass Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings As Required Like Suitable Handle, Star Lock Etc And Minimum 1.5 Mm Thick Section Size Complete All As Specified And Directed By Engineer In Charge Note- Rate Incl For Providing Slide Or Fix Type Mosquito Proofing Shutter And Addl Track If Reqd 20 S&F Powder Coated ( Thickness Of Powder Coating Not Less Than 50 Micron ) Aluminium Door Shutters, Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Comprise With Door Shutter With 85Mm X 45Mm X 1.5Mm Thick Stiles, 100Mm X 43Mm X 1.5Mm Bottom Rails And 85Mm X 43Mm X 1.5Mm Including Lock Rails Complete All As Specified And Directed By Engineer In Charge . 21 S&F 4.8 Mm Thick Sheet Glass Selected Quality Approved Fixed In Position In Aluminium / Iron / Wooden Frame Work Including Rubber Beading And Pointing Cleats / Glazing With Oil Putty Complete All As Specified And Directed By Engineer In Charge 22 S&F Framed Work Such As Grills, Gratings, Etc. With Ends Of Bars Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Con- Forming To Fe.290.Gde-E-165 Complete All As Specified And Directed By Engineer In Charge 23 S&F 6.3 Mm Thick Sheet Glass Exc 0.5 Sqm Selected Quality Approved Fixed In Position In Aluminium / Iron / Wooden Frame Work Including Rubber Beading And Pointing Cleats / Glazing With Oil Putty Complete All As Specified And Directed By Engineer In Charge 24 S&F Ms Butt Hinges Cold Rolled Medium Weight 100Mm Long Complete All As Specified And Directed By Engineer In Charge 25 S&F Ms Butt Hinges Cold Rolled Medium Weight 75Mm Long Complete All As Specified And Directed By Engineer In Charge 26 S&F Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section 200Mm Long Complete All As Specified And Directed By Engineer In Charge 27 S&F Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section 150Mm Long Complete All As Specified And Directed By Engineer In Charge 28 S&F Extruded Aluminium Alloy Handles, Fabricated Type , Anodised 125 Mm In Size Complete All As Specified And Directed By Engineer In Charge 29 S&F Extruded Aluminium Alloy Handles, Fabricated Type , Anodised 75 Mm In Size Complete All As Specified And Directed By Engineer In Charge 30 S&F In Repairs Ms Sliding Door Bolts, Plate Type, Stove Enameled Black, With Bright Bolt Not Less Than 12 Mm Dia And 300 Mm Long Complete All As Specified And Directed By Engineer In Charge 31 S&F In Repairs Second Class Hard Wood Small Fittings Incuding 50 Mm Thick Butt Hinges Such As Brackete Of Any Type , Stopper / Cleat For Door Or Window, Articles N.Exc. 200 Cu Cm Each With Ms Butt Hinges Cold Rolled Medium Weight 50 Mm Long Complete All As Specified And Directed By Engineer In Charge 32 M&L Double Action Floor Spring Hydraulically Regulated Made Up Of Minimum 1.25 Mm Thick Aluminium Alloy Sheet Foundation Box , Main Body With Stainless Steel Cover , Governing Pivot Made Of Brass , Other Parts Made Of Mild Steel Heavy Duty And Fixed Complete All As Specified And Directed By Engineer In Charge 33 S&F In Repair Aluminium Alloy Wire Cloth, 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Beading To Wooden Frames With Aluminium Wire Staples Complete All As Specified And Directed By Engineer In Charge 34 M&L 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing Complete All As Specified And Directed By Engineer In Charge 35 M&L For 5Mm Thick Solid Pvc Wall Lining Consisting Of Single Side Prelam Pvc Sheet Of Wooden Grain Printed Pvc Sheet Color Inclusive Of Solvent Cement Without Relevant And Fixing At Site On Pvc Frame Complete All As Specified And Directed By Engineer In Charge 36 S&F Anodised Aluminium Frame For Pations With One Or More Rebates Incl Joining Cleat For Fixing Etc Complete All As Specified And Directed By Engineer In Charge 37 S&F Sheet Glass 5.5 Mm Thick Sheet Glass, Selected Quality In Square Not Exc. 0.50Sqm In Each Pane Complete All As Specified And Directed By Engineer In Charge 38 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles And Rubbish Off The Premises Complete All As Specified And Directed By Engineer In Charge 39 M&L Glazed Ceramic Tiles In Vertical Surface 300 X 450 X 7Mm Thick Incuding Rendering 10 Mm Thick Cement Mortar ( 1:4 ) To Receive Tiles In Vertical Surfaces All As Specified Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Complete All As Specified And Directed By Engineer In Charge 40 M&L Non-Skid Colour Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tiles Exc 0.11 Sqm But Not Exc 0.18 Sqm As In Floors Including Screed Bed Or Bedding Layers Of 15 Mm Thick Cement Mortar ( 1:6 ) For Laying Floor Finishes All As Specified. Set And Jointed In Cement Slurry @ 3 Kg / Sqm And Pointed In White Or Colour Cement To Match Existing Surfaces Complete All As Specified And Directed By Engineer In Charge 41 M&L Vitrified Ceramic Tiles 8 To 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc Including Screed Bed Or Bedding Layers Of 15 Mm Thick Cement Mortar ( 1:6 ) For Laying Floor Finishes All As Specified. All As Specified Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engineer In Charge 42 M&L Vitrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Skirting / Dado Etcincuding Rendering 10 Mm Thick Cement Mortar ( 1:4 ) To Receive Tiles In Vertical Surfaces , Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engineer In Charge 43 Demolition Of Un-Reinforced Cement Concrete In Ground Floor And Paving Not Exceeding 15 Cm Thick ( Below Or Above Ground Level ) Complete All As Specified And Directed By Engineer In Charge 44 M&L For 75Mm Thick Cement Concrete 1:3:6 Type C2 Using 40Mm Graded Stone Aggregate As In Plinth Protection Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer In Charge 45 Supply Only 38Mmx1, 5 Mm Plastic Dividing Strips As In Floors Complete All As Specified And Directed By Engineer In Charge 46 M&L Cement Concrete ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate As In Floor Topping, 40Mm Thick, Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer In Charge 47 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Including All Quoins, Pillars Etc. Complete All As Specified And Directed By Engineer In Charge 48 M&L Fly Ash Brick Work With Sub-Class `B Bricks, Straight Or Curved On Plan Exceeding 6 M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed By Engineer In Charge 49 M&L Fly Ash Brick Work With Sub Class ‘B’ Brick Straight Or Curved On Plan To Any Radius In Half Brick Wall In Cement Mortar 1:4 Complete All As Specified And Directed By Engineer In Charge 50 M&L 10 Mm Thick Cm Plaster In Cm ( 1:4 ) Mixed With Water Proofing Compound @3% By Weight Of Cement Over While The Padding Concrete Is Still Green Complete All As Specified And Directed By Engineer In Charge 51 Supply Only Liquid Water Proofing Compound 52 M&L For Rendering 15Mm Thick In Cm 1:3 Cement Plaster On Fair Faces Of Brick Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement, With Water Proofing Compound @3% By Weight Of Cement Complete All As Specified And Directed By Engineer In Charge 53 Taking Down Cement Plaster On Brick Or Stone Walls Etc, Including Raking Out Joints, Hacking For Key Scrubing Down With Water Etc Complete All As Specified And Directed By Engineer In Charge 54 M&L 15Mm Thick Rendering In Cement Mortar ( 1:6 ) On Any Face Of Brick Walls Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer In Charge 55 M&L Rendering / Plastering, 10Mm Thick In Cement Mortar ( 1:4 ) On Any Face Of Brick Walls Or Concrete Surfaces, Using Wpc, Surfaces Finished Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer In Charge. Note: Wpc Shall Be Measured And Paid Separately. 56 Cutting Chases, Pinning In, Making Good To Facing Where Required And Pointed In Cement Mortar 1:3 And Making Good Cutting Exceeding 10 Cm Exc 20 Cm Girth Complete All As Specified And Directed By Engineer In Charge. 57 Taking Up Or Down 15Mm Dia Gi Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed By Engineer In Charge.          58 Taking Up Or Down 20Mm Dia Gi Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed By Engineer In Charge.          59 S&F In Gi Tube 15 Mm Dia ( Isi Marked ) Medium Grade Galvanished With All Fittings Laid In Floors / Wall Etc. Complete All As Specified And Directed By Engineer In Charge. 60 S&F In Gi Tube 20 Mm Dia ( Isi Marked ) Medium Grade Galvanished With All Fittings Laid In Floors / Wall Etc. Complete All As Specified And Directed By Engineer In Charge. 61 Refixing Of 15Mm Dia Old Steel Tubing And Connections In New Or Old Position ( Walls, Ceiling, Floors, Etc. ) Complete All As Specified And Directed By Engineer In Charge. 62 Refixing Of 20Mm Dia Old Steel Tubing And Connections In New Or Old Position ( Walls, Ceiling, Floors, Etc. ) Complete All As Specified And As Directed. 63 S&F Pvc Ball Valve 20Mm Dia High Pressure Of Ptmt With Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe Complete All As Specified And Directed By Engineer In Charge 64 S&F In Repairs Gun Metal Gate Valves, With Iron Wheel Head, Screwed Both Ends For Gi Pipe 20 Mm Bore And Fixed Complete All As Specified And Directed By Engineer In Charge 65 S&Fin Repairs Vitreous China Glass Round Wash Basin, White, Flat Back, Size 580X450 Mm Excluding Taps, Waste, Chain And Plug And Porcelin Stopper But Including Brackets Complete All As Specified And Directed By Engineer In Charge 66 S&F In Repairs Vitreous China White Single Piece Washdown Watercloset Pedastal Pattern 69 X 36 X 74 Cm Including Necessary Lime Concrete And 100 Mm Bore Cast Iron ‘S’ Trap With 550 To 600 Mm Long Neck For Connecting Wc To Branch Piece With Cement Joints, Including Necessary Connections Low Level Flushing Cistern 2 / 4 Ltrs Capacity And Jet Pressure With Nozzle Complete All As Specified And Directed By Engineer In Charge 67 S&F Pvc Connections 15 Mm Size With Ptmt Nuts Of Length 450 M Complete All As Specified And Directed By Engineer In Charge 68 S&F Pvc Waste Pipe 32Mm Dia Of Length 900Mm Ptmt Complete All As Specified And Directed By Engineer In Charge 69 S&F For 600Mmx450mm Looking Mirror Of Selected Quality Glass Mounted Of 9Mm Thick Of Commercial Plywood And Pvc Mouldings Frame Fancy Type Complete All As Specified And Directed By Engineer In Charge 70 S&F In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long. 71 S&F In Repair Towel Rail, 20Mm Dia Brass Chromium Plated, 600Mm Long With Fancy Type Brass Chromium Plated Brackets On Both Sides And Fixed With Steel Screws And Wooden / Rawl Plugs Complete All As Specified And Directed By Engineer In Charge 72 S&F In Repairs 125Mm Dia Cp Brass Shower Rose With Swivel Joints, Any Colour Including Shower Arm 15Mm Dia, 195Mm Long With Bend Of 45 Degree With Flange Of Cp Brass Complete All As Specified And Directed By Engineer In Charge 73 S&F In Repairs 15Mm Bore Stop Valves Of Cast Copper Alloy, Screwed Down, High Pressure With Crutch Or Butter Fly Handle, Fancy Type, Chromium Plated, With Long Shank And Cup ( Concealed Type ) Complete All As Specified And Directed By Engineer In Charge 74 S&Fin Repairs Stop Cock Cast Copper Alloy Screwed Down, High Pressure With Crutch Or Butter Fly Handle, Screwed Both Ends For Iron Pipe Or Union Of 20 Mm Bore Complete All As Specified And Directed By Engineer In Charge 75 S&F In Repairs Fancy Type Long Neck Bib Taps, Cast Copper Alloy, Chromium Plated Screwed Down For 15 Mm Bore Iron Pipe Or For Brass Ferrule Complete All As Specified And Directed By Engineer In Charge 76 S&F Shelf Ptmt Fixed To Wall With Steel Screws And Pvc Rawl Plug Complete All As Specified And Directed By Engineer In Charge 77 S&F In Repairs 19 Mm Dia Mild Steel Curtain Rod Powder Coated With Fixing Side Brackets, End Cups, Rings @ 10 Nos Per Running Metre And Fixed With Pvc Rawl Plugs & Steel Screws Complete All As Specified And Directed By Engineer In Charge 78 Dismantling Asbestos Cement / Pvc Pipe 50 / 75 / 100 Mm Dia Including Clamps Complete All As Specified And Directed By Engineer In Charge 79 S&F In Repair Low Density Polythene Pipe ( Ldpe ) Of Pressure Rating 6 Kg Per Sq.Cm, Heavy Duty Laid In Trenches Size 50Mm Bore Of Pipe Complete All As Specified And Directed By Engineer In Charge 80 S&F 110Mm Dia Pvc ( Swr ) Pipes Single Socketed, In Any Length, Laid In Trenches Or In Floors / Fixed To Walls Complete All As Specified And Directed By Engineer In Charge 81 S&F 75Mm Dia Pvc ( Swr ) Pipes Single Socketed, In Any Length Fixed To Walls / Floors Or In Trenches Complete All As Specified And Directed By Engineer In Charge 82 S&F Pvc ( Swr ) Bends Any Radius, 110Mm Bore, Fitted With Oval Access Door Complete All As Specified And Directed By Engineer In Charge 83 S&F Bend Suitable For 110Mm Dia Pvc ( Swr ) Pipe Complete All As Specified And Directed By Engineer In Charge 84 S&F Pvc ( Swr ) Bends Any Radius, 75Mm Bore, Fitted With Oval Access Door Complete All As Specified And Directed By Engineer In Charge 85 S&F Pvc ( Swr ) Reducers Any Radius 110Mm Bore Complete All As Specified And Directed By Engineer In Charge 86 S&F 110Mm Bore Pvc ( Swr ) Junction, Single ( Single T ) Equal Or Unequal With Or Without Door Access Complete All As Specified And Directed By Engineer In Charge 87 S&F Pvc ( Swr ) Vent Cowl 75Mm Dia Complete All As Specified And Directed By Engineer In Charge 88 S&F Contemporary Health Faucet With Metal Hose And Holder As Available In Polished Chrome Mimiumum 500 Gm Weight Make: Kohler Catalague No. 12927In-Cp Or Equivalent In Jaquar / Grohe As Approved By Age ( I ) 89 S&F Self Adhesive Metal Bathroom Corner Rack Storage Shelves Of Dimesions 36X26.7 X6 Cm Complete All As Specified And Directed By Engineer In Charge 90 M&L For Applying Two Coat Of White Wash On Old Decorated Surfaces Of Ceiling And Cornices Including Preparation Of Old Plastered Surfaces By Brooming Down Or Steel Wire Brushing Scrapping Down Smoke Shoots, Moulds, Moss And Efforescent Salts, Trading Oil And Greasy Spots Etc Complete All As Specified And Directed By Engineer In Charge 91 M&L Preparation Of New Undecorated Plastered Surface Of Walls And Applying Two Coat Of Colour Distemper Oil Emulsion Over One Coat Of Primer On Wall Complete All As Specified And Directed By Engineer In Charge 92 M&L For Complete Removal Of Existing Treatment And Applying Two Coat Of Oil Bound Distemper ( White Or Tinted ) Over A Coat Of Whiting On Wall Complete All As Specified And Directed By Engineer In Charge 93 M&L Preparation Of Plastered Surfaces Of Wall And Applying Two Coats Of Exterior Wheather Coats ( As Per Manufacturers Instruction ) Over A Coat Of Wall Putty Complete All As Specified And Directed By Engineer In Charge 94 M&L For Complete Removal Of Existing Treatmentand Applying Two Coats Of Exterior Wheather Coats ( As Per Manufacturers Instruction ) Over A Coat Of Wall Putty Complete All As Specified And Directed By Engineer In Charge 95 M&L For Prepration Of New Or Previously Untreated Surface And Applying Two Subsequent Coat Of White Wash On Walls Complete All As Specified And Directed By Engineer In Charge 96 M&L For Removing Loose Dust Partcies And Surface Is Wet Approxmiate Damp Proof Cleaning To Be Done And Appying One Coat Of Wall Primer Then Applying Two Coats Of Texture Painting Over The Exisitng Wall Of Desired Pattern And Proper Application Tools As Per Design And Direction Given By Enginner In Charge 97 M&L For 12Mm Thick Toughened Glass Door And Fitted To Top And Bottom Hardwood Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass With Necessary Pivot Hinge, , Cut Outs And Holes Suitable For H Handle ( 2Nos For Each Side ) , Backer Rod, Silicon Sealant With Ceiling Bearing ( Including Two Nos Of Locking Arrengments ) Complete All As Specified And Directed By The Engr-In-Charge. 98 M&L 12Mm Thick Toughened Glass Partition With Hatching Design / Pattern As Approved And Fitted To Top And Bottom Rail To Floor And Ceiling Hardwood Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass With Necessary Fitting Arrangements And Gaps Are Filled With Silicon Sealant Complete All As Specified And As Directed By Age ( I ) 99 M&L For French Polishing On Surfaces Of Any Description, Width Or Girth Including Cleaning And Preparing The Surface Including A Coat Of Wood Filler On New Works With Two Coats As Directed By The Age ( I ) 100 M&L For Two Coat Of Synthetic Enamel Paint Over A Coat Of Pink Primer On Wooden Surfaces Of Any Description Not Other Wise Described Over 10 Cm Width Or Girth Including Preparation Complete All As Specified And As Directed. 101 M&L Preparing Of Old Decorated Wood Or Wood Base Surface Of Any Description Over 10 Cm Width Or Grith Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed. 102 M&L For Point Wiring For One Light Point Controlled By One Switch With 1.5 Sqmm ( Nominal Area ) Unsheathed Multi-Stranded Copper Conductor Pvc Insulated Cable 1100 Volts Grade Single Core Frls Drawn With Pvc Conduit Of 19 / 20 Mm Dia, Orasper Is Concealed Frls Wiring, Along With 1.5 Sqmm Unsheathed Multi Stranded Copper Conductor Cable Pvc Insulated 1100 Volts Grade As Earth Continuity Conductor Connected To Common Earth Dolly Fixed To Wall / Ceiling Roof Excluding Modular Metal Flsh Box And White Cover Palate With Frame The Switches, Sockets, Fan Regulator Etc As Required Suitable For Modular Type Fitting / Fixture Trll Complete All As Specified And Directed By Engineer In Charge 103 All As Per Sl Item No. 102 Above But For One Fan / Exhaust Fan Point Controlled By One Regulator / Switch. 104 All As Per Sl Item No. 102 Above But For One 3 Pin Socket Outlet 5 Amps Socket On Same Board 105 All As Per Sl Item No. 102 Above But For One 3 Pin Socket Outlet 5 Amps Socket On Independent Board 106 All As Per Sl Item No. 102 Above But With 2.5 Sqmm Cable For One 3 Pin Socket Outlet 15 Amps On Independent Board With 2.5 Sqmm Cable As Earthing Conductar 107 S&F For Modular Switch, 1 Way, 6A, 1 Module Complete All As Specified And Directed By Engineer In Charge 108 S&F For Modular Switch, 1 Way, 16A, 1 Module Complete All As Specified And Directed By Engineer In Charge 109 S&F Modular Socket, 6A, 2 / 3 Pin Combined, 2 Module Complete All As Specified And Directed By Engineer In Charge 110 S&F Modular Socket, 6A / 16A, 2 / 3 Pin Combined, 2 Module Complete All As Specified And Directed By Engineer In Charge 111 S&F For Modular White Cover Plate With Frame, 2 Module Complete All As Specified And Directed By Engineer In Charge 112 S&F For Modular White Cover Plate With Frame, 3 Module Complete All As Specified And Directed By Engineer In Charge 113 S&F For Modular White Cover Plate With Frame, 4 Module Complete All As Specified And Directed By Engineer In Charge 114 S&F For Modular White Cover Plate With Frame, 6 Module Complete All As Specified And Directed By Engineer In Charge 115 S&F For Modular White Cover Plate With Frame, 12 Module Complete All As Specified And Directed By Engineer In Charge 116 S&F For Modular Metal Flush Box, 2 Module Complete All As Specified And Directed By Engineer In Charge 117 S&F For Modular Metal Flush Box, 3 Module Complete All As Specified And Directed By Engineer In Charge 118 S&F For Modular Metal Flush Box, 4 Module Complete All As Specified And Directed By Engineer In Charge 119 S&F For Modular Metal Flush Box, 6 Module Complete All As Specified And Directed By Engineer In Charge 120 S&F For Modular Metal Flush Box, 12 Module Complete All As Specified And Directed By Engineer In Charge 121 M&L For Ceiling Rose, 3 Phase Fire Rated Polycarbonate, Isolated Body Complete All As Specified And Directed By Engineer In Charge 122 S&F Stepped Type Electronic Fan Regulator Modular Type All As Specified And Directed By Engineer In Charge Complete All As Specified And Directed By Engineer In Charge 123 S&F For Sub Main Wiring For Circuit Of Size 2 X 6.0 Sq.Mm Along With Earth Wire Of Size 1 X 6 Sq.Mm, Single Core, Pvc Insulated Copper Coductor ( Frls ) Cable In Concealed / Surface / Recessed Pvc Conduit Complete All As Specified And Directed By Engineer In Charge 124 S&F For Sub Main Wiring For Circuit Of Size 2 X 4.0 Sq.Mm Along With Earth Wire Of Size 1 X 4 Sq.Mm, Single Core, Pvc Insulated Copper Coductor ( Frls ) Cable In Concealed / Surface / Recessed Pvc Conduit Complete All As Specified And Directed By Engineer In Charge 125 S&F Power Unit For 1.5 / 2 Ton A.C Including Connecting Electric Connections, Complete All As Specified And Directed By Engineer In Charge 126 S&F Sheet Metal Enclosure Powder Coated Single Door Outdoor Type For Distribution Board, Spn 8 Way Db With Degree Of Protection Ip 54 , Detachable Gland Plate, Box Insertion Marks •, Circuit Identification Label •, Neutral Link , Earth Link , Tin Plated Copper Bus Bar Including , Disconnecting Electric Connections, Dismantling From Position Unserviceable Dbs For Taking Into Credit Complete All As Specified And Directed By Engineer In Charge 127 S&F Mcb Spn 32- 63 A , B Curve Including , Disconnecting Electric Connections, Complete All As Specified And Directed By Engineer In Charge 128 S&F Mcb Sp 06 A To 32 A , B Curve Including , Complete All As Specified And Directed By Engineer In Charge 129 S&F 2X2 Led Fitting 36 Watt , 3600 Lm , 6500 K Suitable For Led Recessed Full Lit Luminaire With Glare Free Uniform Illumination With Longer Life And Less Maintenance Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size And Lamp Complete All As Specified And Directed Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size. Complete All As Specified And Directed . Make : Crompton Lctlrne-36-Fo-Cdl, Or Equivalent In Philips, Wipro As Approved By Age ( I ) 130 S&F Ceiling Fan Sweep 1200 Mm Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed By Engineer In Charge. 131 S&F Exhaust Fan 250 Mm 5 Blade Exhaust Fan ( White ) , Pvc Body, Rust Proof Body And Blades, Double Ball Bearing With Noiseless Operation, 1400 Rpm Complete With Louvers Including Making Suitable Opening At Suitable Height, And Provision Of Nuts And Bolts On The Wall For Fixing The Exhaust Fan Complete All As Specified And Directed By Engineer In Charge 132 S&F Water Heater Storage Type, Electric, Capacity 25 Litres.Bee 5 Star Rated Complete All As Specified And As Directed 133 S&F Air Cooled Split Unit Air Conditioner Electric Driven, Single Phase Of Capacity Of 1.5 Tr, Bee 5 Star Rated Complete All As Specified And As Directed 134 S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 130 V To 300 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva 135 M&L For New Earthing Complete With Galvanised Steel Plate Earth Electrode 600X600x6mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meter Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Gi Wire 4Mm At Two Points By Means Of Bolts And Nut, Check Nut And Washers Including Charcoal Dust, Common Salt, Necessary Excavation In Hard / Dense Soil, Returning Filling In And Removal Of Surplus Soil To A Distance Up To 50Metres, Pcc Pit In 1:3:6 Type Ci ( Using 20Mm Grade Stone Aggregate ) Rcc 1:2:4 Type B-1 ( Using 20Mm Grade Stone Aggregate ) 50Mm Thick Pit Cover, Reinforced With 8Mm Dia Tmt Bars 75Mm C / C, Both Ways Ms Handle 12Mm Dia, Gi Funnel, Wire Mesh And Gi Watering Pipe Of 20Mm Bore Gi ( Light Grade ) And Earth Lead Protection Pipe 20Mm Bore ( Light Grade ) All As Specified, Directed And Shown In Electrical Plate No 3 Of Ssr Part-I Including Testing Complete. Note : Gi Strip And Protection Pipes 20 Mm Gi Light Grade Up To 7.5 Metre Is Included In Unit Rate And Beyond That The Same Will Be Measured Separately. 136 S&F For Gi Wire 4 Mm On Wall / Batten Or Recessed Or Buried In Ground All As Directed

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-09-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-09-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 15400.0 /-
Tender Value
INR 7.70 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail