Housing Urban and Rular Development Government Departments Closing in 0 days TDR #29021610

Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Police District Under South 24Th Parganas. (Fresh Call) Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Polic

Issued by Government Departments · Maheshtala P.S, West Bengal
Tender Value
44.81 Lakhs
Estimated cost
Bid Submission
14 Sep 2021
0 days left
EMD
89636
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Maheshtala P.S → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Police District Under South 24Th Parganas. (Fresh Call) Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Police District Under South 24Th Parganas. (Fresh Call)

BOQ

Name of Work: Repair and Renovation of Residential Quarter at Maheshtala P.S. in Diamond Harbour Police District Under the District of South 24 Parganas.
Sl. No. Item Description
1Civil work
2Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
3Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
4Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. 1st Floor
5Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. 2nd Floor
6Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. 3rd Floor
7Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. 4th Floor
8Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof. (a) upto 150 mm. thick
9Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 1st Floor (a) upto 150 mm. thick
10Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 2nd Floor. (a) upto 150 mm. thick
11Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 3rd Floor. (a) upto 150 mm. thick
12Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.4th Floor. (a) upto 150 mm. thick
13Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
14Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 1st Floor
15Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 2nd Floor
16Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 3rd Floor
17Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 4th Floor
18Removalof rubbish,earth etc.from the working site and disposal of thesame beyond the compound ,inconformity with the Municipal/Corporation Rules for such disposal,loading in to truckand cleaning the site in all respect as per direction of Engineer in charge
19Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used)completes as per direction.(a) Single brick flat soling (thickness 75 mm.)
20Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.a) Depth of excavation not exceeding 1,500 mm.
21Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiringshoring.
22Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis ofmeasurement of finished quantity of work)(a) With earth obtained from excavation of foundation.
23(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A)With PakurVariety 1:3:6
24Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
25Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, 1st Floor
26Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, 2nd Floor
27Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, 3rd Floor
28Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, 4th Floor
296 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety 1st Floor
306 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety 2nd Floor
316 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety 3rd Floor
326 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety 4th Floor
336 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety GROUND FLOOR
34Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL GROUND FLOOR
35Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL 1st Floor
36Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL 2nd Floor
37Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL3rd Floor
38Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL 4th Floor
39Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.CGround Floor
40Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C1st Floor
41Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C2nd Floor
42Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C3rd Floor
43Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C4th Floor
44Brick work with 1st class bricks in cement mortar (1:6) in (a) In foundation and plinth
45Brick work with 1st class bricks in cement mortar (1:6) in (b) Ground Floor Superstructure
46Brick work with 1st class bricks in cement mortar (1:6) in 1st Floor
47Brick work with 1st class bricks in cement mortar (1:6) in 2nd Floor
48Brick work with 1st class bricks in cement mortar (1:6) in 3rd Floor
49Brick work with 1st class bricks in cement mortar (1:6) in 4th Floor
50125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground floor
51125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 1st Floor
52125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 2nd Floor
53125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 3rd Floor
54125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 4th Floor
55Labour for Chipping of concrete surface before taking up Plastering work.
56Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. at Floor Ground floor
57Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. at Floor1st Floor
58Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. at Floor2nd Floor
59Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. at Floor3rd Floor
60Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative WALL Ground floor
61Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative WALL1st Floor
62Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative WALLr2nd Floor
63Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative WALL3rd Floor
6418 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground floor
6518 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]1st Floor
6618 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]2nd Floor
6718 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]3rd Floor
68Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stoneslab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Ground floor
69Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stoneslab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]1st Floor
70Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stoneslab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]2nd Floor
71Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stoneslab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]3rd Floor
72Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.
73Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour Ground floor
74Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour1st Floor
75Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour2nd Floor
76Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour3rd Floor
77Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (iii) 35 mm. thick Ground floor
78Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (iii) 35 mm. thick1st Floor
79Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (iii) 35 mm. thick2nd Floor
80Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (iii) 35 mm. thick3rd Floor
81Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (iii) 35 mm. thick4th Floor
82Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm Ground floor
83Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm1st Floor
84Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm2nd Floor
85Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm3rd Floor
86Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
87Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (1st Floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
88Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (2nd Floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
89Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (3rd Floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
90Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (4th Floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
91Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plasterOUTSIDE
92Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (1st Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plasterOUTSIDE
93Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (2nd Floor).[Excluding cost of chipping over concrete surface](ii)/c/ With 1:4 cement mortar ,c) 10 mm thick plaster. Ceiling Plaster
94Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (3rd Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plasterOUTSIDE
95Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (4th Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plasterOUTSIDE
96Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar c) 15mm thick plaster INSIDE
97Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (1st Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar c) 15mm thick plaster INSIDE
98Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (2nd Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar c) 15mm thick plaster INSIDE
99Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (3rd Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar c) 15mm thick plaster INSIDE
100Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (4th Floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar c) 15mm thick plaster INSIDE
101Net Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqmts Ground floor
102Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface
103Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
104Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
105Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :On timber or plastered surface.With super gloss (hi-gloss) -Two coats (with any shade except white)
106Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :On steel or other metal surface.With super gloss (hi-gloss) -Two coats (with any shade except white)
107Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cementincluding the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.b) 25 mm thick
108Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer\"s specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
109Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer\"s specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).
110White washing including cleaning and smoothening surface thoroughly.(b) Two coats (to be done on specific instruction).All floor
111Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)i) Water based interior grade Acrylic Primer(a) One CoatAll floor
112Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(a) One Coat Ground floor
113Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(a) One Coat1st Floor
114Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(a) One Coat2nd Floor
115Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(a) One Coat3rd Floor
116Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(a) One Coat4th Floor
117Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two CoatsAllfloor
118Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat)a) Normal Acrylic Emulsion Ground floor
119Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat)a) Normal Acrylic Emulsion1st Floor
120Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat)a) Normal Acrylic Emulsion2nd Floor
121Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat)a) Normal Acrylic Emulsion3rd Floor
122Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat)a) Normal Acrylic Emulsion4th Floor
123Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)All floor
124Scraping and removing greasy soot from walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface.All floor
125Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately) upto 2.5 sqm.
126a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr upto 16kg/sq.mtr.GROUND FLOOR
127a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr upto 16kg/sq.mtr.1st Floor
128a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr upto 16kg/sq.mtr.2nd Floor
129a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr upto 16kg/sq.mtr.3rd Floor
130a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr upto 16kg/sq.mtr.4th Floor
131Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick
132Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian Ground floor
133Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian1st Floor
134Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian2nd Floor
135Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian3rd Floor
136Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian4th Floor
137Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) Ground floor
138Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)1st Floor
139Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)2nd Floor
140Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)3rd Floor
141Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iii) 35mm thick shutters with 19mm thick panel.(b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. Ground floor
142Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iii) 35mm thick shutters with 19mm thick panel.(b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.1st Floor
143Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iii) 35mm thick shutters with 19mm thick panel.(b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.2nd Floor
144Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iii) 35mm thick shutters with 19mm thick panel.(b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.3rd Floor
145Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iii) 35mm thick shutters with 19mm thick panel.(b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.4th Floor
146Supplying fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core so as to import monolitaheic composite structure as per approved technology of Departmant of Science (DST) to satisfy IS : 4020 door testing performance .(ii) 66mm x 70mm
147Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 25 mm thick
148Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod.
149(v) Two point nose aluminium handle including fitting and fixing.
150(vi)steel peg stay 300 mm long including fitting and fixing.
151Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (a) 40mm X 6mm, 250mm Length
152Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm
153i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm long
154(ii) Anodised aluminium floor door stopper
155Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (iii) 100mm long x 10mm dia. bolt.
156Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (vi) 200mm long x 10mm dia. bolt.
157Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor
158Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement@160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer\"s specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600(longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) with written permission of Superintending Engineer
159Supplying and laying standard four course bituminous water proofing treatment as per specification laid down in I.S. 1346 - 1991 to be finished with pea size gravel including necessary preparatory works such as shaping mouth of outlets, cutting as and where necessary and refilling with sand and Cement mortar (4:1) or Cement Concrete (1:2:4) with graded stone chips before undertaking the treatment including cutting grooves in parapet and inserting edge of felt and mending good damage complete in all respect as per direction of Engineer - in - Charge including cost of all materials andlabours and incidental charges but excluding the cost of Cement Mortar or concrete required for levelling and grading. (In sloped roof Course sand of approved varieties is to be used in place of Pea size gravels as fourth and final course.) i) 1st and 3rd Course with bonding materials of hot applied industrial blown type bitumen of grade 85/25 or 90/15 conforming to I.S.702 - 1988 @ 12Kg/10Sqm on each layer. ii) 2nd course with Hessian base self finished bitumen type- 3 Gr.-I conforming to I.S. 1322-1993 (weighing 23kg/10Sqm gross with bitumen content 12.10kg/10Sqm ) tested under the provision of I.S. 13826 - 1993 part VIIiii) 4th course with washed and clean pea sized gravel or grit @ 0.006 cum/Sqm.A. Over Flat Roof.all Floor
160(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer\"s specification for water proofing layer in water tank etc. (No Departmental Cement is required)All floor
161SANITARY & PLUMBING WORKS :Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Length(a) 75 mm
162Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Lengthb) 110 mm
163Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Lengthc) 160 mm
164Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (i) Coupler(a) 75 mm
165Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (i) Couplerb) 110 mm
166Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Couplerc) 160 mm
167Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (ii) Plain Tee(a) 75 mm
168Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (ii) Plain Teeb) 110 mm
169Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii) Plain Teec) 160 mm
170Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (iii) Door Tee(a) 75 mm
171Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (iii) Door Teeb) 110 mm
172Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Teec) 160 mm
173Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings iv) Door Tee(LH) & (RH)(a) 75 mm
174Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings iv) Door Tee(LH) & (RH)b) 110 mm
175Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings v) Plain Y(a) 75 mm
176Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings v) Plain Yb) 110 mm
177Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsv) Plain Yc) 160 mm
178Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings x) Bend 87.5º(a) 75 mm
179Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings x) Bend 87.5ºb) 110 mm
180Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsx) Bend 87.5ºc) 160 mm
181Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xi) Door Bend (T.S.)(a) 75 mm
182Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xi) Door Bend (T.S.)b) 110 mm
183Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxi) Door Bend (T.S.)c) 160 mm
184Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xiv) Cross Tee with Door(a) 75 mm
185Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xiv) Cross Tee with Doorb) 110 mm
186Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xv) Vent Cowl(a) 75 mm
187Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xv) Vent Cowlb) 110 mm
188Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxv) Vent Cowlc) 160 mm
189Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xvi) Pipe Clip(a) 75 mm
190Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings xvi) Pipe Clipb) 110 mm
191Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxvi) Pipe Clipc) 160 mm
192Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xxxi) Plain Floor Trap with Top tile & Strainer 75 mm
193Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xxiii) 110/110 S Trap 75 mm
194Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xxvi) Reducer 110 X 75 mm75 mm
195Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xxvii) Reducing Tee (110 X 75 mm) 75 mm
196Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xviii) W.C. Connector (450 mm long) W / lipring 75 mm
197Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xxi) 110 X 110 P Trap 75 mm
198Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xIv) Round Jali75 mm
199Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xIvi) Door Cap(a) 75 mm
200Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992xIvi) Door Capb) 110 mm
201Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above ground(i) 75 mm
202Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above groundii) 110 mm
203Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above groundiii) 160 mm
204Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(B) Under ground(i) 75 mm
205Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(B) Under groundii) 110 mm
206Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(B) Under groundiii) 160 mm
207Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)40mm
208Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)32mm
209Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)25mm
210Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)20mm
211Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)15mm
212Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40mm
213Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).32mm
214Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).25mm
215Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).20mm
216Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).15mm
217Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.550 mm X 400 mm size
218Supplying, fitting and fixing pedestal of approved make for wash basin (white)
219Dismantling wash basin with brackets with or without waste fittings.
220Refixing wash basin with brackets with or without waste fittings.
221Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.With \"P\" trap (without vent)
222Dismantling Indian W.C. including taking out base concrete as necessary.
223Refixing Indian W.C. excluding cost of base concrete if necessary complete.
224Dismantling Orissa pattern W.C. including taking out of base concrete, if necessary, complete.
225Cleaning E.P. or Anglo-Indian W.C. with acid.
226Cleaning urinal with channel with acid.
227Removing chokage of water closet.
228Removing chokage of urinal and waste trap.
229Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.Polythene Flush Pipe
230Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.900 mm long
231Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 1050mm long
232Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
233Supplying, fitting and fixing low-down cistern parts.(i) Internal fittings for cistern complete of approved make.
234Supplying, fitting and fixing low-down cistern parts.(ii) Outlet Assembly
235Supplying, fitting and fixing low-down cistern parts.(iii) Intlet Assembly
236Supplying, fitting and fixing low-down cistern parts.(iv) Rubber Kid
237Supplying, fitting and fixing low-down cistern parts.(v) Knob
238Supplying, fitting and fixing low-down cistern parts.(vi) Brackets (pair)
239Supplying, fitting and fixing low-down cistern parts.vii) CP Flush Bend (local) best qualitya) Orrisa & Indian Pattern WC
240Supplying, fitting and fixing low-down cistern parts.vii) CP Flush Bend (local) best qualityb) E. W.C. & Anglo-Indian W.C.
241Renewing bolts and nuts for cistern.
242Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical/ Sumthing Special of ESSCO or similar brand).
243Supplying, fitting and fixing bib cock or stop cock.PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm
244Supplying, fitting and fixing pillar cock of approved make. b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent).
245Dismantling pillar cock of wash basin.each
246Refixing pillar cock of wash basin.
247Fixing brackets for wash basin/ sink/ drain board/ cistern.
248Supplying, fitting and fixing soap holder.PTMT (Prayag or equivalent)
249Supplying, fitting and fixing PTMT Smart Shelf of approved make of size 300 mm.
250Supplying, fitting and fixing towel rail with two brackets. C.P. over brass iii) 25 mm dia. and 750 mm long
251Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
252Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.Sink only 530 mm X 430 mm x 180 mm
253Dismantling sink with brackets with or without waste fittings.(ii) Above 450 mm and upto 600 mm length
254Refixing sink with brackets with or without waste fittings.(ii) Above 450 mm and upto 600 mm length
255Cleaning wash basin/ sink with acid.
256(g) PTMT overhead shower ( Prayag or equivalent)(ii) 150 mm round
257Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as perdirection, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all externalsurfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.i) With Pakur variety. (SAIL/TATA/RINL)
2583 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting andfixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removingspoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% byweight of cement with all costs of labour and materials. Note:- (i) Finished level ofSeptic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm.Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part-I.Payment will be made separetly on the basis of actual height based on relevantI.S.Code.(ii) For 50 usersA) With Pakur variety. (SAIL/TATA/RINL)
259Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.(SAIL/TATA/RINL)
260Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. Upto 50 users:- Within a lead of 150 metre
261Cleaning silt of inspection pit.
262Dismantling & Refixing pit cover
263Supplying, fitting and fixing in position C.I. manhole/ pit cover with rim.a) Round(i) 450 mm X 100 mm X 21 kg (approx.)
264Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab.
265Cleaning silt of master trap pit.
266Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer2000 Litre capacity
267Labour for hoisting plastic water storage tank.Above 1500 litre upto 5000 litre capacityOn the roof of mumty(top of forth floor)
268Labour for punching hole in plastic water storage tank upto 50 mm dia.
269Electrical Schedule Work :Supply & fixing 3/4\" thick water & vermin proof super quality ply wood of size (8\" ft x 4\" ft) to be fixed on wall with suitable long screws fastener etc after painting the rear side with black japan paint.
270Connecting & dressing Meter looping system with 2 x 6 + 1 x 4 sq mm PVC insulated copper wire duly layed on the Ply board by link clipfrom Bus Bar to Meters & Meters to DP MCBs (Ave 4 meters)(Pwd page-E3,9 Item no. 1
271Supply & fixing 415V 125A capacity MS (16SWG) Busbar Chamber having dimension of (500x150mm) to be fixed on iron frame on wall consisting of 4 nosCU bars of size (4x15x3mm). The same BBC should have a separate cubicle at one end consisting 3 nos 125A capacity porcelain cut out fuse unit & one nutral bar to receive the service cable including connecting the cut out fuse units with the BBC by S/F 4 x 35 sqmm PVC insulated copper wire duly socketed at both ends incl. earthing attachment & painting as required .(Pwd page-D13 Item no. 19 (b) (2 set 0.8 mtr per set)
272Supply & fixing of 240V 32A DP MCB (Legrand) in DP SS enclosure (Legrand) incl earthing attachment. ( FOR ROOF LIGHTING all bul.)(Pwd page-D6,9 Item no.7;11)
273Supply & Fixing (2+12) way SPN MCBDB (Legrand cat no- 607712) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnectionwith suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand):(Pwd page-D 6;9 Item no. 7,13)a) 63A DP MCB isolator & necy. connection--- 1 nob) 6 to 25A SP MCB as required breaking capacity 10KA & C characteristic---- 12 nos
274Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(Pwd page-F2 Item no. 1 (a)a)4 x 50 sq mm
275Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(Pwd page-F2 Item no. 1 (a)b) 2 x 6 sq mm
276Laying of the following XLPE Al armoured cable aftercutting floor /pavement / wall and making holes incl, embedding tha cable at an average depth as below& mending good the damages to original finish:-(Pwd page-F 3 Item no. 5)a)2x 10 sq mm ( dp to spn)
277Laying of the following XLPE Al armoured cable aftercutting floor /pavement / wall and making holes incl, embedding tha cable at an average depth as below& mending good the damages to original finish:-(Pwd page-F 3 Item no. 5)b)2 x6 sq mm
278Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection(Pwd page-F6 Item no. 11)A) 40 mm dia
279Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection(Pwd page-F6 Item no. 11)b)80 mm dia
280Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:(Pwd page-F 4;5Item no.7;8)a)4 x 50 sq mm
281Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:(Pwd page-F 4;5Item no.7;8)c) 2 x 6 sq mm
282Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1)a)2x4+1x2.5 sq mm though 25mm Alka Pipe(AC )
283Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1)b) 2x2.5+1x1.5 sqmm through 19mm Alka.pipe ( P/P)
284Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1)c) 3x1.5 sq mm through 19mm Alkathene pipe
285Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [only PVC casing-capping on ceiling and remaining portion concealed] (AVG run 6 mtr)(Pwd page-E23 Item no.8)
286Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded \"FR\" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pinmodular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 moduleGI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (on board)(Pwd page-E20 Item no.3)
287Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded \"FR\" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pinmodular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 moduleGI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (Ave run 4.5 mtr)(Pwd page-E20 Item no.3)
288Supply & fixing of Modular type computer plugboard of 8module GI box with cover plate recessed in wall comprising of the following(All cabtree):a) 16A socket---1 setb) 16 a switch --- 2 setb) 6A socket--- 2 sets
289Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cuwire and earth continuity wire etc(Pwd page-E19Item no.17)
290Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wirE(AC )(Pwd page-E17Item no.5(a)
291Supply & fixing of Modular type 16A3 pin modular type plug socket (Brand approved by EIC) with 16 A Modular type switchwithoutplug top on of 4 module GI box with cover plate recessed in wall comprising of the following (All cabtree): (Pwd page-E18Item no.9(b)a) 16A switch---1 set b)16A socket - -1 set
292Supplying and fixing PVC Rigid Conduit \"FR\" [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works(PWD page E-16 Item no.7)(a) 20mm size
293Supplying and fixing PVC Rigid Conduit \"FR\" [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works(PWD page E-16 Item no.7)(b) 25 mm size
294Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles(Pwd page-E 3 Item no.6,7)a)19 mm dia 3mm thick polythene pipe without earth continuity wire
295Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles(Pwd page-E 3 Item no.6,7)b)25 mm dia 3mm thick polythene pipe without earth continuity wire
296Fixing only singal / twin fluorescent light complete with all accessories directly on wall/ceilinh/HW round block and suitable size of MS fastener,ceiling plate, nipples etc. as required(Pwd page-C 2 Item no.14(D)
297Supply & Fixing louver AL shutter on wall with necy. bolts & nuts (6 mmdia x 62 mm long) as following diameter(Pwd page-D14Item no.32(a)A) 9\" Exhaust fan(23cm)
298Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:(Pwd page-c4Item no.28)9\" Exhaust fan(23cm)
299Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.(Pwd page-E18Item no.10)
300Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board.(Pwd page-D 13Item no.20(c)
301Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.64 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtrlong) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level. .(Pwd page-G 1Item no.2(a)
302S & F earth busbar of galvanized (Hot Dip) MS flat 25mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required(Pwd page-G 2Item no.4(a)
303S&F GI waterproof type looping cable box size 200x15x100 mm deep having 4 mm thick comprising of one 250 v 15 A kit-kat fuse unit, one NL on procelain insulator. One compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machane screws etc. earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick. MS claps with bolts, nuts etc. including painting with anticorrosive paint(Pwd page-H 5 Item no.5)
304Fixing only outdoor / street light typelight fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting(Pwd page-C3Item no.19)
305Electrical Non Schedule Item :Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC) a)4 x 50 sq mm
306Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC) b)2x10 sqmm
307Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC) c) 2 x 6 sq mm
308Supply of4\" 20W single LED Tube light fittings with mounting rail(make CromptonCat.No -IGP 131 LT8-16, 1X20w LT8-20-865-2-20W / philips) .
309Supply of4\" 20W TwinLED Tube light fittings with mounting rail(make CromptonCat.No -IGP 132 LT8-16, 2X20w LT8-20-865-2-20W / philips) .
310Supply & fixing72 w LEDfitting (Make Ceompton, Cat no. LSTP-72-CDL72 / philips)
311Dismenting the existing installation and depositing the dismenting materials to the authority and mending good the damages.

AI Tender Summary

OUR REF NO 29021610
AUTHORITY Government Departments
TENDER VALUE 44.81 Lakhs
LAST DATE 14-09-2021
Authority
Authority Name West Bengal State Police Housing Corporation Limited
Work Description Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Police District Under South 24Th Parganas. (Fresh Call) Repair, Renovation And Upgradation Of Residential Quarters At Maheshtala P.S. In Diamond Harbour Police District Under South 24Th Parganas. (Fresh Call)
Basic Detail
Tender No WBPHIDCL/EE(HQ-I)/NIT- 52(e)/2021-2022
Bidding Type Tender
Location
City Maheshtala P.S
State West Bengal
Key Dates
Publish Date 27 Aug 2021
Submission Date 14 Sep 2021
Open Date 16 Sep 2021
Finance
Tender Value 44.81 Lakhs
Tender Fee Ref. Documents
EMD 89636
Exemption Not Available
Document List
3b962562-565e-4271-b87c-ec3a180892bf.html
BOQ_653416.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 16, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3b962562-565e-4271-b87c-ec3a180892bf.html

xls

BOQ_653416.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders