Supply Installation Testing Commissioning Of Earthing System - 2 Earthing System Complete With Copper ( Cu ) Plate 99% Pure Copper Of 600 X600 X 5 Mm, Copper Strip Of 99% Pure Copper Of 25X5mm From Copper Plate To Earthpit Termination , G I Pipe For , Nangloi and c-Haryana

Airports Authority Of India has published Supply Installation Testing Commissioning Of Earthing System - 2 Earthing System Complete With Copper ( Cu ) Plate 99% Pure Copper Of 600 X600 X 5 Mm, Copper Strip Of 99% Pure Copper Of 25X5mm From Copper Plate To Earthpit Termination , G I Pipe For . Submission Date for this Tender is 14-09-2021. Electrification Work Tenders in Nangloi and c Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

29020342
Corrigendum : Supply Installation Testing Commissioning Of Earthing System - 2 Earthing System Complete With Copper ( Cu ) Plate 99% Pure Copper Of 600 X600 X 5 Mm, Copper Strip Of 99% Pure Copper Of 25X5mm From Copper Plate To Earthpit Termination , G I Pipe For
Open Tender
Indian
Haryana
Nangloi and c
14-09-2021

Tender Details

Supply Installation Testing Commissioning Of Earthing System - 2 Earthing System Complete With Copper ( Cu ) Plate 99% Pure Copper Of 600 X600 X 5 Mm, Copper Strip Of 99% Pure Copper Of 25X5mm From Copper Plate To Earthpit Termination , G I Pipe For Watering 50Mm Dia Of Minimum 3.5 Meter Long Or More ( As Per Site Requirement ) With Earthing Pit Cover, And All Accessories / Items , Installation Materialetc., As Per Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc, 3 Copper Strip Of 99% Pure Copper ( Cu ) 25X5mm. With All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 4 Pvc Insulated Copper Cable 70 Sqmm Of Plain Annealed Copper Conductor Having Purity Of More Than 99.9 % And Having Natural Fr Pvc Insulation Of Minimum Thickness 1.4Mm2 And Current Resistance Of 0.275 Ohms / Km Along With 20 Pieces Of Copper Thimbles With Cablesand All Accessories / Items , Installation Materialetc., As Per Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc, 5 Pvc Insulated Copper Cable 25 Sq Mm Of Plain Annealed Copper Conductor Having Purity Of More Than 99.9 %, And Having Natural Fr Pvc Insulation Of Minimum Thickness 1.4Mm2 And Current Resistance Of 0.750 Ohms / Km Along With 50 Pieces Of Copper Thimbles Along With Cable &All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 6 Hdpe Pipe: Hdpe Pipe Minimum Diameter Of 50 Mm For Protection / Layingof Copper Stripwith All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 7 Earthing Bus Bar: 99% Pure Copper ( Cu ) Earth Distribution Plate ( 300 Mm X 50 Mm X 5 Mm ) Having At Least 8 Holes With Ssnut And Bolt Of M8 Size With All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 8 Conventional Lightning Arrestor Fabricated Using 99% Pure Copper Rod With All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 9 Earth & Ground Resistance Tester Kit With All Accessories / Items, Installation Materialetc As Per The Requirements Of The Tender Inclusive Of All Charges, Levies, Freight Charges Etc 10 Cost Of Installation, Testing & Commissioning : 11 Installation Testing And Commissioning Of Complete Earth System As Per Tender Requirements. 12 Laying Of Hdpe Pipes, On Wall / Roof / Soil 13 Installation Of Copper Strip On Wall Or On Floor / Roof Or Through Hdpe Pipe ( Laid Vide S.No. 2.2 Above ) As Per Site. 14 Installation Of Pvc Copper Cables On Wall Or On Floor / Roof Or Through Hdpe Pipe ( Laid Vide S.No. 2.2 Above ) As Per Site. 15 Installation, Testing And Commissioning Ofconventional Lightning Arrestor .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Sep-2021 Corrigendum1 Technical Bid 14-09-2021

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
INR 18.42 Lakhs /-

BOQ Items

Name of Work SITC of Earthing System ( E_TenderId. 2021_AAI_81166)
Sl. No. Item Description
1Cost of Supplies-
2Earthing system complete with Copper (Cu) Plate 99% Pure Copper of 600 X600 X 5 mm,Copper Strip of 99% pure Copper of 25x5mm from copper plate to earthpit termination , G I pipe for Watering 50mm dia of minimum 3.5 meter long or more (as per site requirement) with Earthing Pit Cover, and all accessories/items ,installation materialetc., as per requirements of the tender inclusive of all charges,levies,Freight charges etc,
3Copper Strip of 99% pure Copper (Cu) 25x5mm. with all accessories/items,installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
4PVC insulated copper cable 70 sqmm of Plain annealed copper conductor having purity of more than 99.9 % and having natural FR PVC insulation of minimum thickness 1.4mm2 and current resistance of 0.275 Ohms /KM along with 20 pieces of copper thimbles with cablesand all accessories/items ,installation materialetc., as per requirements of the tender inclusive of all charges,levies,Freight charges etc,
5PVC insulated copper cable 25 sq mm of Plain annealed copper conductor having purity of more than 99.9 %, and having natural FR PVC insulation of minimum thickness 1.4mm2 and current resistance of 0.750 Ohms /KM along with 50 pieces of copper thimbles along with cable &all accessories/items,installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
6HDPE Pipe: HDPE pipe minimum diameter of 50 mm for protection/layingof copper stripwith all accessories/items,installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
7Earthing BUS Bar: 99% pure Copper (Cu) Earth Distribution Plate (300 mm x 50 mm x 5 mm) having at least 8 holes with SSnut and bolt of M8 size with all accessories/items, installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
8Conventional Lightning Arrestor fabricated using 99% Pure Copper rod with all accessories/items,installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
9Earth & Ground Resistance Tester Kit with all accessories/items,installation materialetc as per the requirements of the tender inclusive of all charges,levies,Freight charges etc
10Cost of Installation,testing & Commissioning :
11Installation Testing and Commissioning of Complete Earth System as per tender requirements.
12Laying of HDPE Pipes, on wall/Roof/soil
13Installation of Copper Strip on wall or on floor/roof or through HDPE pipe (laid vide S.No. 2.2 above) as per site.
14Installation of PVC Copper cables on wall or on floor/roof or through HDPE pipe (laid vide S.No. 2.2 above) as per site.
15Installation, testing and commissioning ofConventional Lightning Arrestor .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail