| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-09-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-09-2021 |
| Sl. No. | Item Description |
| 1 | Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare partwill be measured and paid separately under appropriate items ) |
| 2 | Disconnecnting, dismantling and taking out the non functional Air Conditioner window type/Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by andchecking & retightening of all electrical connections.Replacement of minor part such asnut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed.Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only\" under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item.(ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one.(iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item. |
| 3 | Disconnecting, dismantling and taking out the non-functional water coolers of any description, any make and in any position, capacity 40 ltrs to 150 ltrs,including water connections, single phase AC connection, 50 Hz, strip opening, cleaning and servicing of the water cooler with usingMAIC-DS solution with and including taking out and replacing unserviceable/defective wiring & damaged/un-serviceable parts,necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed.Note :-(i) The replacement of defective / nonfunctional parts/damaged body portions shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ Part -I and fixing charges for new/ repaired items are deemed to be included under this item.(ii)Burnt out windings, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ Part-I.(iii)Internal wiring, if any, replaced, shall be measured and paid for separately as \"supply only\"of internal wiring kit.(iv) The rates for above items are deemed to include for transportation of Water coolers to & from workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop& replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one.(v) Charging of gas to make up required pressure, if any, shall be measured and paid separately under appropriate item of Schedule `A\". However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipeline including brazing of damaged portion of pipe line. |
| 4 | Disconnecting and taking out the non-functional Refrigerator/Deep Freezer of any description and in any position, strip opening of Refrigerator/Deep Freezer 165 Ltr. to 490 Ltr. Capacity, cleaning and servicing, taking out un-serviceable / defective parts/spares and internal wiring, replacement of un-serviceable parts/spares like Relay, capacitor, wiring , over load protector, Compressor, inner liner Puff,evaporator, freezer, condenser, Lamp & holdersetc. necessary brazing, reassembling and testing all as specified and directed.Note :-(i) Replacement of un-serviceable parts shall be measured paid for separately under appropriate item ofsch ‘A’ as supply only but fixing and testing element of the parts replaced / repaired is deemed to be included in this item.(ii) The rates for above items are deemed to include for transportation of Refrigerators to & fromworkshop as approved by Engineer-in-charge for necessary repairs and testing of Refrigerators at workshop& replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one.(iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A\". However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. |
| 5 | S&F compressor sealed unit suitable for 1.5 TR Capacityfor any type of window ACSingle Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas (R-22) & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed. Make, Kirloskar,Tecumsha, Whrilpool |
| 6 | All as per Item No. 05 here in above but for Split 1.5 TR capacity |
| 7 | S&F in replacement of Sealed unit compressor for 40/80 ltrs capacitywater cooler including vacuum testing and filling of refrigerant gas to required pressure. |
| 8 | M&L in replacement Sealed unit compressor for 165 ltrs capacity including vacuum testing and filling of refrigerant Gas to required pressure |
| 9 | All as per Item No. 08 here in abovebut for 220 to 320 ltr capacity |
| 10 | All as per Item No. 08 here in abovebut for 330 to 490 ltr capacity |
| 11 | M&L for replacment of old unsv starting relay box carefully from window/Split type A/C1 to 2 TR capacity of any makeincluding making necessary elect connections, |
| 12 | All as per Item No. 11 here in abovebut for water coolers 40 to 150 Ltr capacity |
| 13 | All as per Item No. 11 here in abovebutfor Refrigeratorand deep Freezerany make & type |
| 14 | S&F in replacement over load protector suitable for 1.5AC/WC 40/80 Ltr capacity |
| 15 | All as per item No. 14 here in above but for 2.0 Ton AC / 120ltr WC capacity |
| 16 | All as per Item No. 14 here in abovebut for Refrigerator and Deepfreezer for any size of capacity |
| 17 | S&FThermostat suitable for A/C, Water coolers, Refrigerators, Make- Kelton/Infass/Renutrol |
| 18 | S & Fix repair Starting capacitor 240 V, of the following size complete all as specified and as directed for 80 to 100 MFD |
| 19 | S & Fix repair Starting capacitor 240 V of the following size complete all as specified and as directed for 100 to 150MFD |
| 20 | S & Fix repair of Running capacitor240 Volts of following size for4/6 MFD |
| 21 | S & Fix repair of Running capacitor240 Volts of following size for 30/36 MFD |
| 22 | S & Fix repair of Running capacitor240 Volts of following size for 45/50/60 MFD |
| 23 | M&L for charging of refrigerant gas R-22/R-410Acomplete unit or to make up required pressure in existing air conditioner, window type invertor split AC/hot & cold split AC of any description any capacity any make and in any position complete all as specified and directed complete all as specified and directed. |
| 24 | M&L for charging of refrigerant gas 134A/600A to make up the required pressure in any type refrigerator complete all as specified and as directed. |
| 25 | Disconnecnting and taking out existing defective AC electric motor of any description & in any position of size 1/7 HP to 1/5 HP 230 Volts, strip opening for rewinding and removing to & from workshop for rewinding as apporved by Engr-in-Charge, rewiding with appropriate size copper supper enameled wire as approvedincl insulating material such as illuminous paper, leatherized paper , cotton tape, glass sleeving, insulating varnish etc, testing at workshop to the entire satisfaction of Engr-in-Charge, transpotation & fixing the motor at site incl necessary connecting & testing complete all as specified and directed. |
| 26 | S& F in replacement fan motor AC 230 V high speed suitable for split AC 1.5/2 tonfor any Make of ACall as specified and directed. |
| 27 | Supply and fix in repair copper made Condenser/Evaporator coil assembly complete suitable for 1.5/2.0 Ton window type/Split type AC unit complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed. |
| 28 | Supply and fix in repair copper made Condenser coil assembly complete suitable for all type Refrigerator complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed. |
| 29 | S&F in replacement Swing motor for indoor unit of Split type AC 1.5/2 Ton capacity all as specified and directed. |
| 30 | S&F in replacement of PCB of electronic circuit complete including display panel, signal receiving slot, display PCB (ie Remote) all as per existing one and suitable for 1.5/2 Ton Window type A/C : Make Blue Star, Videocon, LG, Samsung |
| 31 | All as per item No.30 but for 1.5/2 Ton Split Type A/C Ltr capacity |
| 32 | All as per item No 30 but for Refrigerator any make & type. |
| 33 | M & L for repair of defective electronic components in PCB circuit plate ofWindow/split type AC /Refrigerator of anymodel as directed. |
| 34 | Supply and fix in replacement of remote controller unit of Air Conditioner Split Type/Window type of any description any make and in any position 1.5/2 TR capacity |
| 35 | S&F in replacement capillary assembly suitable for 1.5/2 Ton capacity AC |
| 36 | S&F in replacement of selector switch suitable for window type AC 1.5 / 2 ton capacity as per existing pattern |
| 37 | S&F in replacement of front cover including grill panel of window type A/C of capacity 1.5 / 2 Ton as per existing one. |
| 38 | S&F in repair of blower motor suitable for 230 volts three speed of Blower motor three speed 1/7HP to 1/5 HP 900 rpm suitable for 230 volts of 1.5/2 TRAC. |
| 39 | Supply and fix in replacement blower motor 1/10 HP, 1350 RPM suitable forSplit type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. |
| 40 | S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed |
| 41 | S&F in replacement of drain pipe for water Cooler & Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed |
| 42 | M&L for testing of complete existing Window type/Split type AC unit of any description, any make & in any position by vacuum and pressure testing with Nitorgen (N2) and brazing the leakage/damaged copper pipe as required at site and charging of the refrigerant gasto required pressure and testing on completion complete all as directed. Make:- as per existing make of unit. |
| 43 | Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nutof any size as required and inclinsulating material etc and testing complete all asSpecified and directed. |
| 44 | Supply and fixing fan blade of any type and any description suitable for motor of any capacity for AC/water cooler/Refrigeratorcomplete all as specified and directed. |
| 45 | Supply and fixing wall mounting stand suitable for Split type AC incl two coat of paintingcomplete all as specified and directed. |
| 46 | S&F in replacement of flare valves for Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed |
| 47 | S&F of workshop cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC |
| 48 | S&F of workshop cable for lead wire pvc seathed 3 core size 23/0.0076 of multistranded copper conductors for Desert coolers/ refrigerators |
| 49 | M&L for scrapping out old bubbled paint, cleaning the surface, leveling, spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to Water cooler any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note :- painting will be carried out at site by bringing compressor machine rate quoted deemed to be included complete. |
| 50 | All as per item No 49 but for window/Split type A/Cup to 2 TR capacity |
| 51 | Taking out existing damaged/unserviceable copper tube insulation of any description & in any position and supply and fixing new insulation for copper tube of any size complete all as directed . |
| 52 | M&L for Replacement of existing unserviceable / damaged portion of the body of the water coolers i.e. in bottom / top / frame etc. with and including using new, 18 SWG, MS black sheet, cut to size, made to shape and size including necessary mouldings etc and fixing and riveting /bolting with existing parts / portion of the water cooler complete all as specified and directed. |
| 53 | Disconnecting dismanlting and taking out the functional Air Conditioner window type of any description any make and in any position 1.5/2 TR capacity Single Phase 50 HZ and reassembling fixing and testing the dismantled AC in new position complete all as specified and directedNote:-(i) The rate for above items are deemed to include for transportation to any distance inside the Army Area as appoved by Engr-in-Charge(ii) Charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A\" |
| 54 | Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directedNote : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing\"s etc with new one brazing of copper pipe & provn of pvc drain pipe of suitable size & length for split AC transpotation to any distance inside the AF area as approved.(ii) Charging of gas in required shall be measured and paid seperatly/under appropriate item of schedule A |
| 55 | M&L for repair of electric wiring, PCB Circuits , relays,contactor etcand replacment of defective wiring of Automatic Voltage Stablizer of 1/2/3/5KVA capacity of any makeand carryout minor repair of PCB by changing resistance,condensor,transistor,indicator lamp,2 way switch ,PVC insulating sleeves etc and making functional complete all as specified and directed at site. |
| 56 | Supply and fix in replacement AC electric condenser motor 25 Watt, 230 Volts, 1250 RPM single speed for water cooler complete all as specified and directed |
| 57 | Supply and fix in replacement AC electric condenser motor 30 to 35 Watt, 230 Volts, 930 RPM single speed for water cooler complete all as specified and directed |
| 58 | S&F in replacement NRV suitable for 40/80 Ltr capacity water cooler storage type as per existing Make and Model. |
| 59 | S&F in replacement chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/150 Ltr capacity storage type water cooler as per existing Make and Model.. |
| 60 | Removing the unserviceable condenser fan motor from the Water cooler of 40/80/150 Ltr capacity and M&L for rewinding of condenser fan motor of capacity 1 / 30 or 1 / 32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, in position connecting up all including testing and refixing complete all as specified and directed. |
| 61 | M&L for opening body of water coolers, taking out cooling tank to rectifiy leakage of refrigerant tube / condensor and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clampingwithGI strip complete all as specified and directed. |
| 62 | M&L for repairing of foundation/bottom base of water coolers any make & type with suitable size angle iron by welding/screwed/screwed/nutbolts after giving proper shape and making good complete all as specified and directed. |
| 63 | Supply only following new parts suitable for refrigerator of any description, make and capacity 165 ltrs to 490 ltrs:- (a)Freezer door with spring & clamp complete all as specified and as directed.Note :- (i) Make of the parts must be same as per existing Refrigerator (ii) The cost of fixing and testing of spare parts is deemed to be included under Schedule `A\" |
| 64 | All as per Item No. 63 here in above butPin type / screw type bulb |
| 65 | All as per Item No. 63 here in above butChiller tray plastic |
| 66 | All as per Item No. 63 here in above butRefrigerator Freezer coil & freezer coil type / roll bound type for 165 ltrs to 230 ltrs capacity |
| 67 | All as per Item No. 63 here in above butRefrigerator Freezer coil & freezer coil type / roll bound type for250 ltrs to 360 ltrs capacity |
| 68 | All as per Item No. 63 here in above but Fan motor of frost free for double door refrigerator of capacity 300 to 360 ltrs |
| 69 | All as per Item No. 63 here in above butFreezer box suitable for all type refrigarator |
| 70 | All as per Item No. 63 here in above butMain door gasket magnetic type |
| 71 | All as per Item No. 63 here in above butBi-metal thermostat of capacity – 5 0 C cut in temperature for 300 to 360 ltrs capacity |
| 72 | All as per Item No. 63 here in above butFreezer defrost Heater |
| 73 | All as per Item No. 63 here in above butDoor shelf bin & retainer bar |
| 74 | Taking down carefully existing unserviceablealuminum/copperpoint wiring (light, fan, socket or power) of any description & in anyposition complete including all fittings& fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etcincluding taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed |
| 75 | M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC casing and capping of adequate size fixed on surface with PVC rawl plugswith sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- (a)One light/buzzer point controlled by one; one way switch.NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers |
| 76 | All as per Item No. 75 here in above but one fan/exhaust fan point controlled by one, one way switch |
| 77 | All as per Item No. 75 here in above but One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. |
| 78 | All as per Item No. 75 here in above but One 3 pin socket out let 5 amp point on the (same board) with other switches. |
| 79 | All as per Item No. 75 here in above but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board. |
| 80 | S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specifiedanddirected. |
| 81 | S&F switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified anddirected. |
| 82 | S & F Bell push, flush type 5 AMPAC 230 Volt single pole complete as specified. |
| 83 | S&F switch socket outlet five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified anddirected. |
| 84 | S&F switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specifiedanddirected. |
| 85 | S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified anddirected. |
| 86 | S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt,designed box type LEDluminaries,CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with electronic ballast, spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wiredand connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specifiedanddirected. |
| 87 | S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting, all as specified and directed. |
| 88 | S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED/CFL lamp fitting complete all as specified and directed |
| 89 | M&L for Sub main wiring with 2 runs of PVC insulated unsheathedmulti stranded single core copper conducter 4 Sqmm drawn through PVC conduit/casing capping including accessaries with 2.5 sqmm PVC insulatedearth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiringand connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length. |
| 90 | Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & Fsheet metal enclosure powder painted forMCB DB SPN08 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by accepting officer |
| 91 | Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & Fsheet metal enclosure powder painted forvertical type MCB DB TPN04 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by accepting officer |
| 92 | Supply and fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
| 93 | Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
| 94 | S&F MCB single pole, 6 to 32 Ampsin `C’ series having current rating 10 KA complete all as specified and directed. |
| 95 | M&L for Disconnecting,taking down and removing of ceiling fan / Exhaust fan / wall mounting fan of any description, any sweep and from any position / locations and connecting upfrom ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying nuts, bolts, canopy, down rod, clamps, capacitor and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed.Note : The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as \"supply only\" under appropriate item of sch \"A\" . The rates for above items are deemed to include for transportation of fans to and from workshop if required and approved by Engr-in-charge for necessary repairs. Burnt out windings replaced and paid for separately under appropraite item of Sch \"A\" . |
| 96 | Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete as directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep |
| 97 | All as per Item No. 96 here in abovebut rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed. |
| 98 | All as per Item No. 96 here in abovebut rewinding of motor of exhaust fans of 375 mm sweepcomplete all as specified and directed. |
| 99 | All as per Item No. 96 here in abovebut rewinding of motor of exhaust fans of 450 mm sweepcomplete all as specified and directed. |
| 100 | All as per Item No. 96 here in abovebut rewinding of motor of air circulating fan/wall mounting fans of 400mm sweepcomplete all as specified and directed. |
| 101 | All as per Item No. 96 here in abovebut rewinding of motor of air circulating fan of 610 mm sweepcomplete all as specified and directed. |
| 102 | All as per Item No. 96 here in abovebut rewinding of motor of pedestal fan of 400 mm sweep complete all as specified and directed. |
| 103 | Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- (a) Supplying only ball bearing No 6201 complete all as specified and directed. |
| 104 | All as per Item No.103 here in abovebut Supplying only ball bearing No 6202 complete all as specified and directed. |
| 105 | All as per Item No.103 here in abovebut Supply only gun metal bushes of any descriptionand size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed. |
| 106 | All as per Item No.103 here in abovebutSupplying only capacitor of capacity 2.5 mfd(PVC body)complete all as specified and directed. |
| 107 | All as per Item No. 103 here in abovebutSupplying only capacitor of capacity 4 mfd(PVC body) complete all as specified and directed. |
| 108 | All as per Item No. 103 here in abovebutSupplying only armature shaftof fans of any description and in any position complete all as specified and directed. |
| 109 | All as per Item No. 103 here in abovebutSupply only PVC canopy of any description and suitable for any type & any makeof fan complete all as specified and directed. |
| 110 | All as per Item No.103 here in abovebutSupply only rubber real of suitable size of hanging assemblywith clamps complete all as specified and directed. |
| 111 | All as per Item No.103 here in abovebutSupply only 450 mm long down rod 15 mm dia of MS tube light grade, factory made , painted & duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified. |
| 112 | All as per Item No.103 here in above but Supply only blade for 1200 mm ceiling fan MS tube light grade, factory made , painted & duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified. |
| 113 | S & F in repairs ceiling fan regulatordeluxe rotary step type 100 Watt suitable for any type of ceiling fan complete all as specified and directed. |
| 114 | Disconnecting electrically and mechanically the existinggeyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed.Note : U/s parts replaced with new one shall be measuredand paid for separately as \"Supply only\" under appropriate item of Sch \"A\" |
| 115 | Supply only the following parts for geysers 50/25 Ltrs capacity ofISI marked (Make of parts shall be as per make of Geysers) : (a) Heating element 2 KW suitable for operation on 230V AC 50Hz |
| 116 | All as per Item No.114 here in above but Heating element 1.5KW suitable for operation on 230V AC 50Hz |
| 117 | All as per Item No.114 here in above but Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser. |
| 118 | All as per Item No.114 here in above but Pressure release valve dead weight type for 25/ 50 Ltrs capacity Geyser. |
| 119 | All as per Item No.114 here in above but Glass wool |
| 120 | All as per Item No.114 here in above but Red indicator/Green indicator. |
| 121 | All as per Item No.114 here in above but Gasket set for 50 litres capacity Geyser |
| 122 | All as per Item No.114 here in above but Gasket set for 25 Ltrs capacity Geyser. |
| 123 | All as per Item No.114 here in above but Antivaccum valve for 25/50 Ltrs capacity Geyser. |
| 124 | Apparatus plate assembly/ Base assembly complete with inlet, outlet and thermostat pipes with drain plug and screws for fixing the element inclusive of clamps for holding element with nut bolts, suitable for 25/ 50 Ltrs capacity geysers, of make : Bajaj/ Racold/ Power pack / Venus or equivalent ISI marked |
| 125 | All as per Item No.124 here in above but Fusible Plug for 25/50 Ltrs capacity Geyser. |
| 126 | All as per Item No.124 here in above but Pressure reducing valve for 25/50 Ltrs capacity Geyser. |
| 127 | All as per Item No.124 here in above but PVC braided flexible connection pipe for inlet and outlet water, 18\" long with two chrome plated brass adaptors, nipples and rubber washers complete. |
| 128 | All as per Item No.124 here in above but Non return valve (ISI marked) 15mm dia Make Kirloskar/Leader. |
| 129 | All as per Item No.124 here in above but Storage tank made up of stainless steel (inner tank), suitable for 25 Ltr capacity geysers. |
| 130 | All as per Item No.124 here in above but Storage tank made up of stainless steel (inner tank), suitable for 50 Ltr capacity geysers. |
| 131 | All as per Item No.124 here in above but Outer shell made up MS sheet, suitable for 25 Ltr capacity geysers. |
| 132 | All as per Item No.124 here in above but Outer shell made up MS sheet, suitable for 50 Ltr capacity geysers. |
| 133 | All as per Item No.124 here in above but Top cover/ Bottom cover for Geyser 25/50 Ltr capacity, as required on site, duly painted with white enamel paint all as specified. |
| 134 | All as per Item No.124 here in above but Bottom cover for Apparatus plate of Geyser 25/50 Ltr capacity, as required on site, duly painted with white enamel paint all as specified. |
| 135 | S & F in repair/ replacement flexible round type PVC sheathed copper cable of size 1.5 sqmm 3 core complete all as specified and directed by Accepting officer |
| 136 | S & F earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts all as specified and directed. |
| 137 | Supply and fixing Brass floatvalve high pressure with polythene float and fly nut complete screwed for GI iron pipe of size 25 mm dia |
| 138 | Supply and fixing Brass floatvalve high pressure with polythene float and fly nut complete screwed for GI iron pipe of size 20 mm dia |
| 139 | M&L for repair of desert cooler of any type and capacity and of any make and making necessary replacement of unserviceable and defective items complete all as specified and directed by engr-in-charge |
| 140 | S&F in replacement of electric pump motor 1/80 HP single phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler. |
| 141 | S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 300 mm Sweep |
| 142 | S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 350 mm Sweep |
| 143 | S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 400 mm Sweep |
| 144 | S&F in replacement of Swing motorsingle phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler. |
| 145 | S & F in replacementwood wool /grass pads of approved quality and size alongwith square mesh of any size as required on ground to suit the existing door size of desert cooler. |
| 146 | S &F in replacement of plastic fan blade 3/4 wing suitable for motor 1/8 HP of desert cooler. |
| 147 | S & F in replacement of5 Amps top 3 pin incl 3 mtr 2.5 Mtr flexible copper wire suitable for desert cooler |
| 148 | S&F in replacement of control switches set of desert cooler as per existing sample |
| 149 | M&L for making new fan motor base incl with clamps, nut bolts, two coat of painting suitablefor existing type of desert cooler all as specified and directed. |
| 150 | S&F PVC transparent pipe set complete for distribution of water of desert cooler (having droping elbow -3 Nos, distribution 3 way ) as per existing size, including clamping by screw/strip all as specified and directed. Note :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance. |