| 1 | Excavation in trenches in soft/loose soil not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth for foundation of poles, trenches for laying of cable or for shafts, wells, cesspits, manholes, pier holes etc. and getting out, complete all as specified and directed. |
| 2 | Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 Mtr above the starting point, complete all as specified and directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, complete all as specified and directed. |
| 4 | M&L for Sub Class \"B\" bricks old size, laid dry flat over the cable abutting each other as in protection of cable, complete all as specified and directed. |
| 5 | M&L for sand cushioning to under ground cable 8cm thick before laying the cable and 15cm thick after laying, stretching and testing the cable, complete all as specified and direted.Note:-only punned thichness shall be considered for payment |
| 6 | Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 35 Sqmm x 3.5 core including taking out existing cable from trenches or fixed to wall/pole or passing through ducts or pipe of any size, any core , complete all as specified and directed. Note:-Excavation andearth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately. |
| 7 | Description all as per Srl item No- 6.00 here-in-before but cable of size 25 Sqmm x 3.5 core complete all as specifed and directed |
| 8 | Description all as per Srl item No- 6.00 here-in-before but cable of size 50 Sqmm x 3.5 core complete all as specifed and directed |
| 9 | Description all as per Srl item No- 6.00 here-in-before but cable of size 10 Sqmm x 2 core complete all as specifed and directed |
| 10 | Supplying, jointing and connecting \"as in replacement\" cable end termination joint kit, indoor, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 11 | Supplying, jointing and connecting \"as in replacement\" cable end termination joint kit, outdoor, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 12 | M&L for replacement of 50mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, incl. taking out old one complete all as specified and directed. |
| 13 | M&L for replacement of 100mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, incl. taking out old one complete all as specified and directed. |
| 14 | S&F for MCCB 4 pole 415 volts AC of capacity 160 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cablescomplete all as specified and directed. |
| 15 | S&F for MCCB 4 pole 415 volts AC of capacity 200 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cablescomplete all as specified and directed. |
| 16 | S&F for MCCB 4 pole 415 volts AC of capacity 250 Amps rating, microprocesser based thermal magnetic release with rupturing capacity 36 KA, including providing thimble for out going cablescomplete all as specified and directed. |
| 17 | Supply and fixing of pole mounted street light factory fabricated junction box of size 300 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer, including taking out existing junction box any type and size complete all as specified and directed. |
| 18 | M&L for repairing servicing and replacement of LT panels unserviceable part including complete broken accessories such as partialy open door, broken door, unserviceable aluminium bus bar, unserviceable/broken locking arrangement, repairing of LT panel legs, welding work, necessary PCC work, excavtation and earth work including disconection and reconnection of cables with suitable size of AI lugs in proper engineering practice, for any size of cables in any capacity LT panel also fixing of LT danger notice plate both side of the panel, complete all as specified and directed. Note :- Only danger notice plate shall be measured and paid separaely. |
| 19 | M&L for painting of LT panel after removing old dust particles,rust, oily portion by rubbing with sand paper and painting a coat of synthetic enamel paint with spray pump, and writing/digital printing, (capacity description date of installaiton, etc complete all as specified and directed. |
| 20 | M & L for Scraping of old paint from the steel tubular pole 9 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of 30 cm alternative green and white strips of each upto 1.5 mtr height using synthetic enamel paint. Repainting the remaining pole and iron parts i.e. U clamps, channels etc above 1.5 mtr height by applying Two coat of aluminium paint, including writing letters or figures (Block, Roman, Italic or Indian) S/L Pole No. and Location code not exceeding 30 cm high, stop, commas, short lines, dashes, hypens, brackets etc. complete all as specified and directed. |
| 21 | S&F in replacement of circular LED highbay light 200 watts fittings with tapered fin design and excellent thermal management along with IP-66 protection complete all as specified and directed. |
| 22 | M&L forearthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.Note:- The quoted rate is deemed to include the cost of 7.5 metre GI earth lead and 7.5 metre GI pipe for protection of earth lead. |
| 23 | Supply and fixing in replacement of 60 Watts LED Street Light luminaire with 01 No spare LED driver of the same cap. and makeincluding taking down old lights. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete having efficiency >100Lm/w, available CCT 5700K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall havepower factor more than 0.95 complete all as specified and directed. |
| 24 | Supply and fixing in replacement of 150 Watts LED Street Light luminaire with 01 No spare LED driver of the same cap. and make including taking down old lights. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete having efficiency >100Lm/w, available CCT 5700K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall havepower factor more than 0.95 complete all as specified and directed. |
| 25 | Note for srl item No 24 & 25 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70.4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W.6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover. |
| 26 | S&F in replacement of MH Lamp 250 Watt tubular clear lamp on location including disconnecting and taking out of old unsv lamp of any type and make from light fitting and replacement of defective, complete all as specified and directed. |
| 27 | S&F in replacement heavy duty VPIT open construction copper ballast 250 Watt HPSV / MHfor street light or flood light fittingincluding disconnecting and taking out of old unsv ballast of any type and make from light fitting and testing,complete all as specified and directed. |
| 28 | S&F in replacement ignitor elctronic 230V suitable 250 Watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv ignitor of any type and make from light fitting and testing, complete all as specified and directed. |
| 29 | S&F in replacement of porcelain lamp holder suitable for E/T lamps of 250 Watt HPSV/MH lamp with base E 27 complete all as specified and directed. |
| 30 | M&L for overhauling & servicing of electrically operatedpanels of hanger sliding steel door. Each panel of approximate size 3.5 to 4.0 Metre in width and 10 Metre in height and from any door of hangers by taking out mechanical parts and electrical connections & carry out repairs of motor, gear box assembly, electric control panel including replacement of unserviceable components / spares / greasing etc. complete and re-assemble / reconnect all the parts/portions including testing to ensure efficient and smooth functioning of door, both electrically & manually etc, complete all as specified and directed. Notes :- 1. Cost of replacement of all defective spares / parts except that covered in srl item No. 31.00 to 33.00 here-in-below are deemed to be included in the unit rate quoted by the contractor.2. Rate shall be quoted for each panel. |
| 31 | Supply only gear of existing pattern / type and make of gear assembly of hanger door repaired under srl item No. 30.00 above, complete all as specified and directed. |
| 32 | Supply only gear box of existing make / pattern and type suitable for hanger door repaired under srl item No. 30.00 above, complete all as specified and directed. |
| 33 | Rewinding of electric motor 1.1 KW / 1.5 HP with super enamelled copper winding wire of same gauge including impregnated paper, varnish and tape etc complete for hanger door repaired under srl item No. 30.00 above, complete all as specified and directed. |
| 34 | Supply, installation, testing and commissioning of 5KV, 50 Hz, series type isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber suitable for 45 Watt, 6.6 Amps runway/taxi light luminaire conforming to relevant FAA/CAO and IS including taking out existing unserviceable transformer etc, complete all as specified and directed. Make: AMA/THORN/ADB Safegate/ HoneywellNotes :- 1. Quoted rates are inclusive of taking out unserviceable transformer from housing box and fixing the new one including making necessary electrical connections. |
| 35 | Supply, installation, testing and commissioning of5KV, 50 Hz, series type isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber suitable for 200 Watt, 6.6 Amps runway/taxi light luminaire conforming to relevant FAA/CAO and IS including taking out existing unserviceable transformer etc, complete all as specified and directed.Make: AMA/THORN/ADB Safegate/ HoneywellNotes :- 1. Quoted rates shall be included of taking out unserviceable transformer from housing box and fixing the new one including making necessary electrical connections. |
| 36 | S&F in replacement 200 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed. |
| 37 | S&F in replacement 45 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed. |
| 38 | S&F in replacement lamp holder for halogen lamp suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable lamp holder of any type/description etc, complete all as specified and directed. |
| 39 | S&F in replacement base plate with breakable coupling suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable coupling of any type/description etc, complete all as specified and directed. |
| 40 | S&F in replacement mounting assembly suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable mounting assembly of any type/description etc, complete all as specified and directed. |
| 41 | S&F in replacement Lens filter of any type/colour suitable for 200 Watt halogen Uni/Bi directional optical design high intensity runway light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.Make: AMA/THORN/ADB Safegate/ Honeywell |
| 42 | S&F in replacement Lens filter of any type/colour suitable for 45 Watt Omni directional taxi way edge elevated halogen lamp taxi light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.Make: AMA/THORN/ADB Safegate/ Honeywell |
| 43 | Servicing and monthly preventive maintenance of Five CCR panels of Make : ATG Airport Ltd Cat Part No. M100CCR-6620-400-PS-EF/LI/LF/FAA or AMA, controlling runway and taxiway halogen lamp light fittings including fault rectification and repair of printed circuit control card (thyristor type) by replacement of unserviceable spares viz transistors / ICs / resistance / capacitor etc. as and when required to keep the CCR Panel functional during contract period. Notes :- (a) System shall be inspected / checked for preventive maintenanceas and when required/ directed by the Engr-in-charge. (b) Quoted rates shall be included of replacement of minor unserviceable spares viz transistors / ICs / resistance / capacitor etc. (c) Labour element for changing spares included in quoted rate.(d) Quoted rate shall be include fault repair as and when required.(e)Fixing element of Printed circuit control cardshall be included in quoted rates which shall be measured and paid as supply only against relevant item.(f) Replacement of unsv spares viz transisters/IC\"s /resistor /capacitor etc shall be same make as per existing in the CCR panel. (g) o1 No experienced technicians shall be provided by the contractor for operating of CCR panels/runway/taxi way light during flying schedule complete all asdirected. (h) Attendence register of technician duly signed by users andEngr-in-charge. shall form basis for payment. |
| 44 | Supply only printed circuit control Power card (thyristor type) suitable for 15 KW CCR panel to suit existing etc, complete all as specified and directed. |
| 45 | Supply only printed circuit control Master card (thyristor type) suitable for 15 KW CCR panel to suit existing etc, complete all as specified and directed. |
| 46 | Supply, laying and testing in replacement of 6 sqmm, single core, 5KV grade stranded copper conductor PVC insulated and sheathed runway cable laid in trenches / wall / pipe jointed using plug receptacle including taking out unserviceable cable of any type / description etc, complete all as specified and directed. Make:- AMA/UNTEL/NEXANSNotes :- 1. Excavation and earthwork required for dismantling and taking out cable will be measured and paid separately under respective items of BOQ.2. Serviceable cable shall be segregated for reuse in same or new location, quoted rate are included for segregation for serviceable cable.3. plug receptacle connector (ESSMA) shall be measured and paid separately under respective item od BOQ). |
| 47 | Supply only in replacement ofplug receptacle connector (ESSMA) suitable for 5KW, 6 sqmm copper conductor cable etc, complete all as specified and directed.Make : ATG Airport Ltd / AMA or equivalent as approved, |
| 48 | S&F in replacement of panels indicator LED lamps RYB-03 Nos including green 04 Nos suitable for 240 VAC complete all as specified and directed. Make : ATG Airport Ltd / AMA or equivalent as approved, |
| 49 | S&F in replacement of two position panel selector switch complete all as specified and directed. Make:- C&S/Havells/L&T |
| 50 | S&F in replacement industrical panel socket of rating 16A-6h, 2P+Earth of cap 200-250 VAC complete all as specified and directed.Make:- C&S/Havells/L&T |
| 51 | S&F in replacement industrial panel socket of rating 63A-6h, 3P+N+Earth of cap 240-415 VAC complete all as specified and directed.Make:- C&S/Havells/L&T |