Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-09-2021 | Bid opening date update | Date | 15-09-2021 |
| 2 | 26-08-2021 | Tender Notice Pg 3 modification | Other | 15-09-2021 |
| Sl. No. | Item Description |
| 1 | SITE CLEARENCE |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | BARRICADING |
| 4 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. |
| 5 | Earth Work |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 7 | TREATMENT OF SOIL UNDER EXISTING FLOORS |
| 8 | Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | P.C.C |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 11 | CENTRING & SHUTTRING |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Suspended floors, roofs, landings, balconies and access platform |
| 17 | STEEL |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | RCC |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 21 | All R.C.C. work upto plinth level |
| 22 | All works above plinth level upto floor V level |
| 23 | FILLING |
| 24 | Construction of embankment with approved material obtained from borrow pits cu.m (including cost of compensation for earth taken from private land) with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 25 | 1 km @ 131.17Rs.,[email protected] = =Rs.383.47 |
| 26 | BRICK WORK UPTO PLINTH |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 28 | DAMP-PROOF COURSE |
| 29 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 30 | BRICK WORK ABOVE SUPERSTRUCTURE |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 6 coarse sand) |
| 32 | HALF BRICK WORK |
| 33 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 34 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 35 | PLASTER WORK |
| 36 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand |
| 37 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 38 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) |
| 39 | PAINT |
| 40 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 41 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 42 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 43 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm |
| 44 | VIRTIFIED TILES |
| 45 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm |
| 47 | GRANITE FLOORING |
| 48 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab upto 0.50 sqm |
| 49 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete 8mm thick Granite of any colour and shade |
| 50 | GRANITE EDGE MOULDING |
| 51 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 52 | TACTILES FLOORING |
| 53 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 54 | WASHING AREA ROOFING |
| 55 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 56 | GLASS FOR ELEVATION |
| 57 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 58 | ROLLING SHUTTER |
| 59 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 60 | Providing and fixing ball bearing for rolling shutters. |
| 61 | DOORFRAME |
| 62 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb |
| 63 | FLUSH DOOR |
| 64 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 65 | FLUSH DOORPAINT |
| 66 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 67 | SLIDING DOOR BOLTS |
| 68 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 69 | 300x16 mm |
| 70 | TOWER BOLTS |
| 71 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 72 | 300x16 mm |
| 73 | HANDLE |
| 74 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 75 | 300x16 mm |
| 76 | DOOR STOPER |
| 77 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 78 | 300x16 mm |
| 79 | ALLUMINIUM WORK |
| 80 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 81 | WINDOWS GLASS |
| 82 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 83 | PVC DOOR FOR TOILET |
| 84 | Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer\"s specifications and direction of Engineer-in-charge. |
| 85 | GRANULAR SUB BASE |
| 86 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant atoMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motorgrader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 87 | KERB STONE |
| 88 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 89 | DRAIN COVER |
| 90 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer- in-charge |
| 91 | M.S. WORK |
| 92 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 93 | CEMENT CONCRETE FLOORING |
| 94 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 95 | SOAK PIT |
| 96 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long co mplete as per standard designWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 97 | BORE PIPE FOR RAIN WATER HARVESTING |
| 98 | Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : |
| 99 | PAINTING IN M.S. WORK |
| 100 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 101 | PLUMBING WORK TOILET & PLANTATION |
| 102 | CPVC PIPE |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 104 | 15 mm dia. nominal bore |
| 105 | 20 mm dia. nominal bore |
| 106 | BIB COCK |
| 107 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 108 | STOP COCK |
| 109 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 110 | 15 mm nominal bore. |
| 111 | Providing and fixing uplasticised PVC connection pipe with brass unions : 15 mm nominal bore |
| 112 | BALL VALVE |
| 113 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 114 | 25 mm nominal bore (Horizontal) |
| 115 | TERRACE TANK |
| 116 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 117 | W.C. |
| 118 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid |
| 119 | WASH BASIN |
| 120 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap |
| 121 | SOIL WASTE PIPE |
| 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.100 mm nominal inner dia Pipes |
| 123 | 75 mm diameter : |
| 124 | CLAMPS |
| 125 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 126 | for 110 mm dia pipe |
| 127 | for 75 mm dia pipe |
| 128 | DRAIN POINT |
| 129 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :Sand cast iron S&S as per IS: 3989 |
| 130 | MIRROR |
| 131 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia |
| 132 | SOAP DISH |
| 133 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 134 | DOUBLE EQUAL JUNTION |
| 135 | Providing and fixing double equal plain junction of required degree. |
| 136 | 100x100x100mm Sand cast iron S&S as per IS - 1729 |
| 137 | 75x75x75x75 mm Sand cast iron S&S as per IS - 1729 |
| 138 | BENDS |
| 139 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete |
| 140 | 100 mm diameter pipe Sand cast iron S&S as per IS - 1729 |
| 141 | 75 mm diameter pipe Sand cast iron S&S as per IS - 1729 |
| 142 | URRINAL |
| 143 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 144 | MANHOLE |
| 145 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1.68 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : |
| 146 | MANHOLE COVER |
| 147 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 Rectangular shape 600x450 mm internal dimensions |
| 148 | TRUSS WORK |
| 149 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 150 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m² |
| 151 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : |
| 152 | Ridges plain (500- 600 mm) |
| 153 | Gutter ( 600 mm over all girth). |
| 154 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ringconforming to IS : |
| 155 | 110 mm diameter |
| 156 | Providing and fixing on wall face unplasticised - PVC mouldedfittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. |
| 157 | Coupler 110 mm |
| 158 | Bend 87.5 degree 110 mm bend |
| 159 | Shoe (Plain) 110 mm Shoe |
| 160 | Providing and fixing unplasticised -PVC pipe clips of approveddesign tounplasticised-PVCrainwater pipesbymeansof 50x50x50mmhardwoodplugs,screwedwithM.S.screwsofrequiredlength including |
| 161 | WATER PROOFING SUNKEN PORTION |
| 162 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 163 | WATER PROOFING TREATMENT |
| 164 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 165 | SIGNAGE |
| 166 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activatedretro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). |
| 167 | PAINTING TRUSS WORK |
| 168 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 169 | S.S. RAILING |
| 170 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 171 | FIRE FIGHTING WORK - M.S.Pipe |
| 172 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia |
| 173 | Passage railing Main Building |
| 174 | FIRST AID HOSE REEL |
| 175 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m |
| 176 | HYDRATE VALVE |
| 177 | Supplying and fixing single headed internal hydrant valve with instantaneous unmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel |
| 178 | NON RETURN VALUE |
| 179 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia |
| 180 | HOSE PIPE |
| 181 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 182 | PRESSURE SWITCH |
| 183 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 184 | FLOW SWITCH |
| 185 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. |
| 186 | TERRANCE TANK |
| 187 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 188 | PUMP & CONTROL ROOM |
| 189 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
| 190 | MAIN FIRE PUMP |
| 191 | 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets |
| 192 | Jockey Pump |
| 193 | 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets |
| 194 | DIESEL ENGINE CONTROLControl for diesel engine compr |
| 195 | Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 196 | FIRE BRIGADE CONNECTION |
| 197 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe |
| 198 | HORTICULTURE WORK |
| 199 | Rough dressing the trenched ground including breaking of clods.DSR 2.5 |
| 200 | Fine dressing the ground DSR 2.7 |
| 201 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) DSR 2.13 |
| 202 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)D.S.R. 2.14.2 Holes 90 cm dia, and 90 cm dee |
| 203 | Flooding the ground with water including making Kiaries and dismantelling the same DSR 2.24 |
| 204 | Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. D.S.R. 3.21 |
| 205 | Providing and displaying of Raphis Palm having ht. 75 cm to 90 cm with 15 to 18 equal suckers, well developed, full of fresh and healthy leaves from bottom to top in 35 cm PVC Pots/C.Pots & as per direction of the officer-in-charge D.S.R. 3.77 |
| 206 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. D.S.R. 5.11 |
| 207 | Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. D.S.R. 5.14 |
| 208 | Providing and Displaying Ficus reginold piller type Topiary well developed with fresh & healthy 210 to 240 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge D.S.R. 5.26 |
| 209 | Providing and Displaying Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge. D.S.R. 5.37 |
| 210 | Providing and Displaying Topairy plant of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm t., in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge. D.S.R. 5.40 |
| 211 | Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. D.S.R. 7.3 |
| 212 | Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.D.S.R. 7.7 |
| 213 | Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.D.S.R. 7.16 |
| 214 | Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. D.S.R. 7.24 |
| 215 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-incharge.D.S.R. 7.27 |
| 216 | Providing and stacking of Foxtail palm of ht. 180-210 cm bottom girth 25-30 cm well developed in big size HDPE bags as per direction of the officer-in-charge. D.S.R. 7.43 |
| 217 | Providing and stacking of Jacaranda mimosifolia of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. D.S.R. 7.48 |
| 218 | Providing and stacking of Michelia champa (Golden Champa) of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. D.S.R. 7.55 |
| 219 | Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-chargeD.S.R. 7.69 |
| 220 | Providing and stacking of Hibiscus variegated of height 45-60 cm. with 3-4 branches and healthy variegated foliage in earthen pots of size 20 cm as per direction of the officer-in-charge.D.S.R. 8.38 |
| 221 | Providing and stacking of Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge. D.S.R. 8.50 |
| 222 | Providing and stacking Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. D.S.R. 9.4 |
| 223 | Providing and stacking of Ipomoea purpurea (Morning glory) of height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge D.S.R. 9.7 |
| 224 | Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. D.S.R. 9.12 |
| 225 | Providing and stacking of Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. D.S.R. 9.8 |
| 226 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. D.S.R. 6.12 |
| 227 | Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. D.S.R. 6.6 |
| 228 | Providing and stacking of Tradescantia zebrina having in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.D.S.R. 6.30 |
| 229 | Providing and stacking of Wedelia trilobata, full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge.D.S.R. 6.31 |
| 230 | Providing and stacking of Ophiopogon, Green/Black full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. D.S.R. 6.19 |
| 231 | Bush Rose in different colour 2 to 3 healthy branch 30 cm and above ht. well developed with 8 or more flowers / flower buds in 20 cm Earthen pot / Plastic pot as per direction of the officer-in-charge. D.S.R. 4.90 |
| 232 | Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. D.S.R. 5.12 |
| 233 | Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.D.S.R. 2.35 |
| 234 | ELECTRIC WORK |
| 235 | WGSTLPT Point wiring in PVC conduit, with modular type switch. |
| 236 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 237 | Group C |
| 238 | WGSTLMIDTC Twin Control point wiring inPVC conduit, with modular type switch: |
| 239 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 240 | WGSTLPP2 Power plug wiring inPVC conduit (2x4 sq. mm) |
| 241 | Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 242 | WGSTLSB Circuit/ submain wiring inPVC conduit: |
| 243 | Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 244 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 245 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 246 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 247 | 4 Pair |
| 248 | PVCCON S/F PVC conduit: |
| 249 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. |
| 250 | 25 mm |
| 251 | 32mm |
| 252 | PTSWEB S/F modular type switch/ socket: |
| 253 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 254 | 5/6 amps switch |
| 255 | 3 pin 5/6 amp socket outlet |
| 256 | Telephone socket outlet |
| 257 | MODFREB S/F modular type electronic fan regulator: |
| 258 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 259 | CREB S/F ceilling rose: |
| 260 | Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required |
| 261 | ITCFFSUR ITC fluorescent fitting directly on surface: |
| 262 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 263 | ITCCFFC ITC ceiling fan with cover on fan box: |
| 264 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 265 | ITCEF450 ITC exhaust fan upto 450 mm sweep: |
| 266 | Installation of exhaust fan upto 450 mm sweep in the existingopening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 267 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 268 | 1 run of cable |
| 269 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 270 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 271 | BOARD & DB\"S |
| 272 | PWTPMCBDB S/F TP MCB DB: |
| 273 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 274 | 8 way , Double door |
| 275 | 12 way , Double door |
| 276 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 277 | 8 way (4 + 24), Double door |
| 278 | MCBC S/F \"C\" series, SP MCB |
| 279 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 280 | Single pole |
| 281 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. |
| 282 | 40A |
| 283 | EARTHING |
| 284 | EARGIPL G.I earth plate elctrode: |
| 285 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required.. |
| 286 | EARG125X6 S/L 25 mm x 5 mm G.I. earth strip in ground: |
| 287 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 288 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 289 | Upto 35 sq. mm |
| 290 | Above 35 sq. mm and upto 95 sq. mm |
| 291 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 292 | 3½ X 50 sq. mm |
| 293 | 3½ X 95 sq. mm |
| 294 | 4 X 16 sq. mm |
| 295 | 4 X 25 sq. mm |
| 296 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 297 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 298 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 299 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 300 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 301 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 302 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
| 303 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 304 | speaker cable Single pair, 2-core, 1.5 sqm |
| 305 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. |
| 306 | 25mm |
| 307 | INTERLOCKING TILE |
| 308 | Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504 |
| 309 | Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504 |
| 310 | CAT EYES |
| 311 | Road Studs / Cat Eye: Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flatsurface. |
| 312 | The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 800 page no. 353 and should accompany two year warranty for satisfactory field performance from the manufacturer. |
| 313 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes |
| 314 | SUB HEAD - I (NON SCHEDULED/EXTRA ITEMS) |
| 315 | WATER COOLER |
| 316 | Supplying and fixing Raindrops Stainless Steel Water Cooler, 24\" X 18\" X 52\", Number of Taps: 2 |
| 317 | HIGH MAST LIGHT |
| 318 | Providing and fixing HIGH Mast Light 16 mtr height with 4 nosLED Light including all civil work and fitting work |
| 319 | POLYCARBONATE SHEET |
| 320 | Providing and fixing Polycarbonate sheeting of approved colour and manufacture on ceiling/ roof supported over aluminium section frame work fixed with dash fastener etc. complete as per manufacture specifications and direction of the project Engineer including necessary scaffolding upto ht.of 12mt (10mm thick double walled- LEXAN) |
| 321 | FIRE EXTINGUISHER |
| 322 | Supply and Installation 9 kg fire extinguisher ABC type |
| 323 | S.S.BENCH |
| 324 | Supplying and installation S.S Bench with back rest |
| 325 | SUB HEAD - II (NON SCHEDULED/EXTRA ITEMS) |
| 326 | Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete . Model- Ventil Air - DS (Make :Havells or equivalent) of following size ,complete in all aspects as per direction of Engineer in Charge. |
| 327 | 300 mm sweep 900 rpm |
| 328 | 450 mm sweep 900 rpm |
| 329 | Supply and fixing ofLED Tube light1200mm 20W 865 T8 IP20 ,Lumen Output-1600 , 3000, 4000, 6500K ceiling mounted LED batten (E-LITE LED TRIYCA) , extruded aluminium heat sink provided for efficient heat deissipation 7& integrated electronic driver. ( 1x20 W LED Double 6500K) complet in all aspects as per direction of Engineer in charge. |
| 330 | SUPPLY OF LED Bulb B22, 15 W,6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge. |
| 331 | Suppy of LED Conceild Panel 6-8Watt , 6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge. |
| 332 | Wall Fan 18\" |
| 333 | LT XLPE CABLES |
| 334 | Supply,of following sizes of PVC sheathed LT XLPE armoured, aluminium 1.1KV grade, as required of the following sizes. |
| 335 | 3.5c x 95 sq.mm cable |
| 336 | 3.5c x 50 sq.mm cable |
| 337 | 3.5c x 25 sq.mm cable |
| 338 | 4c x 16 sq.mm cable |
| 339 | Supplying and Fixing All-In-One SOLAR White light emitting diode (30W-LED) Solar Lighting And Solar Home Lighting Lumens / Efficacy 4500 lumens (variability : 10%) / 170 lpw (variability : 10%) Colour temperature, CCT Warm white , 3000K range (variability : 10%) Driver type DC-DC Driver efficiency >90% LM-80 for LED Type of Charge controller MPPT Operating Temperature 0 °C to +50 °C Charge Controller Rating 12V-10Amp DC-DC Driver Rating 28W ± 3W Charge controller Efficiency >94% No load current <20mA Solar Panel Lighting Protection 60V MOV to high voltage protection Protections a) Electronic Open load b) Battery overcharge and deep discharge cut off protection c) Reverse current flow back protection d) Automatic operation dusk to dawn e) Open load/Short circuit/Reverse polarity LED load ,Indications a) Green LED: Charging under progress b) Red LED: Battery discharge /load cut Conforming to standard IS16221 Part 1 & Part 2, EN 50530 IEC 61547 Clause 5.2. Solar panel Capacity60Wp (variability : 10%) Open Circuit Voltage 21Vdc Solar cells Mono-crystalline silicon panel Solar cell efficiency >15% (variability : 10%) Standard IEC 61215, IEC 61730,1,2 Identification RFID Identification tag inside of module Country of manufacturer India with Battery Capacity 12.8V,30Ah LiFePO4 Depth of discharge 80% Standard Confirming to IEC 62133:2012 Make BIS Approved Country of manufacturer India with Pole and foundation as directed by engineer-in-charge |
| 340 | MAIN PANEL |
| 341 | Supply & fixing of main panel with 1 no. incomer of 200 amp.TPN MCCB (25 KA) & outgoings of 06 no. 63 amp. FP MCCB (25 KA) & 02 no. outgong of 40 amp. FP MCCB with suitable busbar, 100Amp change over switch, MFM indicating lampsetc. complete in all respect. |
| 342 | LPACCPT S/F light plug point modular type accessories: |
| 343 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 344 | PPACCPT S/F power plug point modular type accessories: |
| 345 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 346 | PLATFORM CEILING |
| 347 | Providing and fixing platform celing of approved material (metal false ceiling ) thickness .5mm dimensions 600x600mm colour white surface treatment coated material galvanished humidity resistance perforation diameter 1.5mm-2.5mm noise reduction co-effecient/NRC 0.5 |
| 348 | BORING |
| 349 | Boring/drilling bore well connection transportion rig machine 300mm dia in boulders , sand pebbles, rock, 150mm dia 5.4mm thick plain ERW casing pipe, 150mm dia 5.4mm thick slotted ERW casing pipe,s/f 150mm dia casing sue, s/f of 7.5HP 3phase submersible pumps, 10HP 3phase L&T electronic pannel, s/f of 65mm dia MS/HDP column pipe, s/f 6mm dia submersible cable, development of tubewell by air compressor,s/f of elbow nipple, cap, reducer etc, charge of lowering of pump set |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy