| 1 | DESCRIPTION OF ITEMS |
| 2 | Supply, installation, commissioning and testing in replacement of APFC panel of capacity 100 KVAR powder coated factory made outdoor type of suitable size made of Robust steel sheet construction made from min 3.15mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mmx50mmx6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate comprising with following:-(a) Incoming MCCB 4 pole 200 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nosb) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity. Size of capacitor is 1 KVAR =01 No.,2 KVAR = 2 No. 5 KVAR = 1 No, 10 KVAR=1 No., 20 KVAR= 01 No. 30 KVAR=2 No. including indication lamp of each capacitor.(e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank)(f) Auto/Manually switch of capacitor bank(g) PCC 1:2:4 for installation of panel |
| 3 | Supply, installation, commissioning and testing in replacement of APFC panel of capacity 30 KVAR powder coated factory made outdoor type of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-(a) Incoming MCCB 4 pole 63 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nosb) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity. Size of capacitor is 1 KVAR = 01 No., 2 KVAR = 02 No., 5 KVAR = 1 Nos, 10 KVAR=2 No including indication lamp of each capacitor.(e) Microprocessor based 3 phase current transformer sencing relay 6 stage = 01 No( for operating of capacitor bank)(f) Auto/Manually switch of capacitor bank(g) PCC 1:2:4 for installation of panel |
| 4 | S & F in replacement standard duty resin filled capacitor 440 V, 3 phase 5 KVAr. Note : Necessary addition /altration required to adjust capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 5 | All as per Item No.3 above but of 7.5 KVAr |
| 6 | All as per Item No.3 above but of 10 KVAr |
| 7 | All as per Item No.3 above but of 15 KVAr |
| 8 | S & F in replacement contactor 440 V, 3 phase 8.5 KVAr. Note : Necessary addition /altration required to adjust Capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 9 | All as per Item No.7 above but of 10 KVAr |
| 10 | All as per Item No.7 above but of 15 KVAr |
| 11 | Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I - 2009 with aluminum conductor 1100 Volts gradeof cross sectional area 150 Sqmm , 3.5 corein ducts or on walls laid in trenches including taking out old unservicable cablecomplete all as specified and directed. |
| 12 | All as per above but of size 120 Sqmm 3.5 core. |
| 13 | All as per above but of size 95 Sqmm 3.5 core. |
| 14 | All as per above but of size 70 Sqmm 3.5 core. |
| 15 | M & L for replacement of earthing complete with galvanised or steel earth plate electrode of size 600x600x6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected tostrip 32x6mm size with nuts, bolts, check nuts, washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 40mm bore of GI light grade with funnel and wiremesh all as shown in electrical plate No. 3 of SSR -2009 Part I and connecting to earthing test point, main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 including dismantling of old earthing complete all as specified and dirtected by Engineer-in-charge. |
| 16 | Excavation in trenches for laying of cables, foundation of pole etc in any type of soil n.exc. 1.5 mtr wide and n.exc1.5 mtr including taking out old bricks complete all as specified & directed. |
| 17 | Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed. |
| 18 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. |
| 19 | Supply and laying sub class Bbricks old size for protection of cables laid lengthwise perpendicular to the axis of cable, adjecent to each other complete all as specified and directed. |
| 20 | M & L for Sand cushioningng (dry sand) to under ground cable for cable protection provided with layers 8cm thick before laying and 15cm thick after laying the cable and punned down to 18 cm thickness complete all as specified and directed. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 18cm as mentioned in para19.75 of SSR Part-I |
| 21 | Supply and fixing / laying in replacement of galvanized iron pipe of 80mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. |
| 22 | Supply, installation, commissioning and testing in replacementpowdercoated factory made panel board outdoor type confirming to IP 64 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Aluminium bus bar of capacity 500 Amp for phase and 250 Amps for neutral.(b) Incoming MCCB 4 pole 350 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU)– 01 Nos(c) Outgoing MCCB 4 pole 250 Amp 25KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU)– 02 Nos(c) Outgoing MCCB 4 pole 100 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos(d) On load change over switch of capacity 200 Amp– 01 Nos(e)Digital volt meter 0 to 500 volt with selector switch – 01 No(f)Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 01 No(g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three(r) Digital timer switch (Astronomical) along with contractor/MCB and suitable accessories.(g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 23 | M & L for preparing old painted surface of panel board by cleaning removing of the old paint by scracthing with wire bursh/sand paper etc and including denting/patching of brocken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting on inside/outside surface of panel complete all as specified and directed. |
| 24 | M & L in replacement for fabrication of door/surfaces of LT panel indoor/outdoor as per existing size / thickness/shape and fitted in the panel with door handle, formed gasket around doors, lock insets, earthing strips, door stay, hinges,rivetsetc. including two coat of synthetic enamel paint by spray painting on inside/outside surface of panel complete all as specified and directed. |
| 25 | Supply and fix in replacement copper bus bar in the panelof exsiting size and capacity for phase and neutral with heat shrinkable including PVC sleeves in different colour codes for phase indication all as per directed by Engr-in-charge. |
| 26 | All as per item No 25 Above but aluminium bus bar |
| 27 | S & F in replacementLED type phase indication lamp of Red /blue/Green colour for phase indication in existing panels complete all as specified and directed. |
| 28 | S & F in replacement selector 3 way for checking of Amps in 3 phase at different position in existing panels complete all as specified and directed. |
| 29 | All as per item No 27 Above but for checking of voltage. |
| 30 | Supply and fix in replacement of Air circuit brakers 4 pole 415 volts with micro processor release breaking capacity 50 KA manual fixed type of capacity 630 Amps 50 KA in existing panel including making incoming and outgoing connection and required necessary Adl/Alt to provide new ACBs complete all as specified and directed by Engr-in- charge. |
| 31 | S & F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge. Note: Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 32 | All as per Item No.31 above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 33 | All as per Item No.31 above but ofMCCB 315 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 34 | All as per Item No.31 above but ofMCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 35 | All as per Item No.31 above but ofMCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 36 | All as per Item No.31 above but ofMCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 37 | All as per Item No.31 above but ofMCCB 63 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA |
| 38 | Clearing away all grass vegetation, saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearancesoiland getting outincluding spreading of anti vegitation chemical on complete Area all as directed and specified by Engr-in-charge. |
| 39 | S & F in replacement Digital volt meter 0 to 500 volt with selector switch |
| 40 | S & F in replacement Digital Amp meter 0 to 800 Amp including with CT of suitable ratio and selector switch |
| 41 | Maintenance and complete overhauling of servo stablizer of capacity 200 KVA including disassmbling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing wornout parts reassembling of parts including disconnection, connection, well cleaning the complete stablizer, oil tank, connection plate,de-carbonizing all joints, metal parts and making servo stablizer operating in manual and electric mode including all routine testing, calibration complete as well as writing of SM/MES No. complete all as specified and directed.Note: (a) Spray painting of complete servo stablizer shall be deemed inclusive in the quoted unit rate. (b) Any rewiring/changing of cable required for funtioning of stablizer shall be deemed inclusive in the quoted rate. (c) Major Spares to be paid separately under supply only items. |
| 42 | Supply only electronic cards including replacement of all wornout parts like IC\"s , regulators, condensers, Triac, Transistors etc. |
| 43 | Supply only Micro switch. |
| 44 | Supply only R.C. Network for motor |
| 45 | Supply only Carbon Brushes |
| 46 | Supply only New Transhformer Oil of 50 KV Die electric Strength. |
| 47 | Maintenance and complete overhauling of servo stablizer of capacity 5 KVA to 50 KVA including disassmbling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing wornout parts reassembling of parts including disconnection,connection, well cleaning the complete stablizer, oil tank, connection plate,de-carbonizing all joints, metal parts and making servo stablizer operating in manual and electric mode including all routine testing ,calibration complete as well as writing of SM/MES No. all as spd and directed.Note: (a) Spray painting of complete servo stablizer shall be deemed inclusive in the quoted unit rate. (b) Any rewiring/changing of cable required for funtioning of stablizer shall be deemed inclusive in the quoted rate. (c) Major Spares to be paid separately under supply only. |
| 48 | Supply only Electronic cards including replacement of all worn - out parts like IC\"s , regulators, condensers, Triac, Transistors etc. |
| 49 | Supply only Micro switch. |
| 50 | Supply only R.C. Network for motor |
| 51 | Supply only Carbon Brushes |
| 52 | Supply only New Transhformer Oil of 50 KV Die electric Strength. |
| 53 | Supply only Dimmer as per existing capacity |
| 54 | Supply only Gears as per existing capacity |
| 55 | S & F in replacement of Aluminium Lugs/connectors of size 70 sqmm |
| 56 | S & F in replacement of Aluminium Lugs/connectors of size 95 sqmm |
| 57 | S & F in replacement of Aluminium Lugs/connectors of size 120 sqmm |
| 58 | S & F in replacement of Aluminium Lugs/connectors of size 150 sqmm |
| 59 | M & L for repairs & overhauling to LT ACBs of any capacity(400 A to 1000 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and rectifing them, lubrication of moving contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etcreassembling, re-installation, testing & commissioning of ACB complete all as directed by Engineer-in- charge Note :(i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be inclusive in quoted rates |
| 60 | Supply and fixing in replacement of Moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity |
| 61 | Supply and fixing in replacement of fixed Arcing contact and adjust the contact pressure of LT ACB of any make any capacity |
| 62 | M&L for replacement of main shaft assembly with crank & cam spacer ofexisting capacity (630/800 Amp) LT ACB of existing make & model and testing for proper operation complete all as directed by Engineer-in-charge |
| 63 | M&L for replacement of Trip coil of LT ACB of any make any capacity all as specified and directed by Engr-in-charge |
| 64 | M & L for replacement of glow sign board (box type) LED of required size 1200 X 900 mm made out of MS sheet of suitable size with flex sheet of suitable size with flex sheet fixed on front end quality marked with details of electric substation on front and rear with different colours including provision of LED power fittings & fixtures in equal distance to illuminate board including connections with 2.5 sqmmsingle core stranded copper conductor cable in conduit and wiring and fixing of MCB with weather proof box with 10 mm size letters as specified and directed by Engr in charge. |
| 65 | S & F in relacement of LED solar street light 20W All in one type with 2 days back up. complete all as specified and directed by Engr-in-charge. |
| 66 | M & L for grouting of LT/APFC Panel by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate including shifting of existing LT/APFC panel with disconeection of existing cables and reconnecting it after grouting of panel complete all as specified and directed by Engr-in-charge. |
| 67 | S & F in replacement MCB Tripple pole of capacity 20 Amp for suitable for existing APFC Panel contactor/capacitorNote : Necessary addition /altration required to adjust MCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 68 | S & F in replacement APFC Panel Relay micro processor based of 6/8/10 stage suitable for switching of APFC Panel contactor/capacitorNote : Necessary addition /altration required to adjust MCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 69 | M & L in replacement for fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm dixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 200 Amp 25 KA complete all as sepcified and directed incl making connection /thimbles etc complete. |
| 70 | All as per srl item No 68 here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB |
| 71 | M & L for replacement of Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade FRLS typewith copper conductor multistranded cable with lugs on both ends of cable complete all as specified & directed. |
| 72 | S & F in replacement for contactor MNX 40 of existing make/model suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connection all as specified and directed by Engr in charge. |
| 73 | S & F in replacement of air termination, single pointed aluminum rod 12 mm dia and 300 mm long. Note: All accessories for fixing of termination shall be deemded inclusive in the quoted unit rate. |
| 74 | S & F in replacement of aluminum strip 25x3.15mm with saddles and fixing screws etc for roof conductor and down conductors aboveground all as specified & directed. |
| 75 | S & F in replacement for galvanized iron strip 32x6mm buried into ground all as specified & directed by Engg-in-charge. |
| 76 | S & F in replacement of test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8 mm dia, 25mm long, hex head screw complete all as specified & directed. |
| 77 | M & L for replacement for GI tube light grade galvanized with all fittings fixed complete inwalls and floor / ceiling of 25mm dia all as specified & directed. |
| 78 | S & F in replacement of PVC DMC blocks with nut bolts in PCC blocks. Note: All additional items required for fixing and connecting to strip is included in the quoted rate. |
| 79 | S & F in replacement of timer digital type suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connectionall as specified and directed by Engr in charge. |
| 80 | M&L for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase, Black For Neutral & Green For Earth concealed in wall and drawn in with and including PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor taking down of old unserviceable wiring complete all as specified and as directed. (Note : 1. Three runs of 4 Sqmm and one run of PVC conduit shall be measured as one unit. 2. Cost of cutting chasing and making good of surface shall be deemed included in quoted unit rate. |