Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A Spec, GE DEOLALI-Maharashtra

Military Engineer Services-MES has published Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A Spec. Submission Date for this Tender is 06-09-2021. Electrical Maintenance Tenders in GE DEOLALI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

28956253
Corrigendum : Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A Spec
Open Tender
Indian
Maharashtra
GE DEOLALI
06-09-2021

Tender Details

Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-09-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 41200.0 /-
Tender Value
INR 20.60 Lakhs /-

BOQ Items

NAME OF WORK : SPECIAL REPAIR/REPLACEMENT TOEXTERNAL ELECTRICAL SERVICES AND UNSERVICEABLE/ OLD VINTAGE STREET LIGHTS FITTINGS , AT PAO AND ANAND NIKETAN AREA AND PROVN OF PREPAID AUTOMATIC METER READING SYSTEM AND BILLING SOFTWARE FOR PRIVATE PARTIES UNDER THE AOR OF GE DEOLALI
Sl. No. Item Description
1Taking down old u/s street light fitting and S&F 70 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device Suitable for pole dia Ø 54 mm (max.). Make Havells Cat Part Num:-ENDURACITYLINERNE OSL70WLED 757 PASYBOTG or or Philips Model No- BRP409 LED 060 CW HE NR PC S1 PSU GR ( Green line)or Wipro Model No-LR02-671-XXX-57-G2 ( Skyline) or Bajaj Model No- BRTFG 60W LED V3 WW (EDGE LED)
2Supply and fix cable PVC insulated stranded aluminium conductor cable 1.0 sqmm flat/round three core 1100 volts grade complete all as specified and directed
3M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing withMS clamps -1 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia-2 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as directed at site.
4Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizesand aluminium lugs for connection complete all as specified and directed of2 core 10 sqmm size
5All as item No above but3.5 core 35 Sqmm
6Supply,Laying , jointing and testing HT underground cablein replacement heavy duty, 11000 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 120 sqmm 3 core size.
7Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
8Supplying,fixing, jointing and testing heat shrinkablecableendjoint , out-door typewith and including jointing materials suitable for 11 KV , XLPE cable of size 120 sqmm , 3 core , complete all as specified and directed .
9S&F tubing "lightgrade" galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of80 mm bore
10All as item No-9 above but 40 mm bore
11Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
12Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
13Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick complete all as specified and directed
14M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
15Supplying and laying unreinforced precast concrete HT cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
16M&L for providing of new sub class "B" bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
17S & F stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1including necessary MS clamps complete all as specified and directed.(excavation earth work ,PCC work and stay wire will be measured and paid separetaly)
18M&L for galvanized steel wire 7/40.0m dia for stay.
19M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work all as specified.
20M & L for scrubbing out old paint,rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2"" size with white paint lettering on black base all as directed at site .(work shall be completed in the stipulated period as directed).
21Supply, installation and testing HT gang operated air break switch in replacement11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Ampsand 9 insulators suitable for 11 KV, complete all as specified and directed.
22S&F drop-out fuse unit,expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11kv working pressure fixed to and including MS channel with nuts, bolts and washers etc, systhetic bounded fuse tube complete with line cap suitable for current carrying capacity upto 100 Amps all as directed.(set of three)
23Supply & fix Thermo plastic street light sintex box of size 280 X 170 X 130 mmCat No GS-JB-2817 top Hinged ( or equivalent make of National) wiith MCB TPN 32 Amps for looping of cablefor 3 Phase and 1 neutral fixed on polewith the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside the box.
24Supply and fix , test , commissioning of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3 mm thickouter and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyincluding provn of digital ammeter 0-500A,digital voltmeter 0-500Volts, CT"s of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of panel board should not be less than 0.4m)a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No b) MCCB 4 Pole 36 KA250 Amp - 1 No (I/C) c) MCCB 4 Pole 36 KA 160 Amp- 1 No (O/G) d) MCCB 4 Pole 25 KA63 Amp - 6 Nos (O/G)
25All as pr item No 24 above but with following accessoriesa) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB4 Pole 35 KA160 Amp - 1 No (I/C) c) MCCB4 Pole 25 KA63 Amp- 5 No(O/G)
26All as pr item Noabove but with following accessoriesa) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No b) MCCB4 Pole 50 KA400 Amp -1 No (I/C) c) MCCB4 Pole 36 KA250 Amp -1 No(O/G)d) MCCB4 Pole 36 KA160 Amp -2 No(O/G)e) MCCB4 Pole 30 KA63 Amp -1 No(O/G)
27M&L for earthing complete with galvanized earth electro of size 600X600X6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI all as shown in plate no. 3 of MES sch. Pt 0I, connected to earthing test point necessary excavation, earth work, PCC, RCC cover, watering by funnel etc., all as specified and directed by Engineer-in-Charge complete including testing on completion
28Taking down carefullyby discionneting and unscrewing from boards/outlet boxes, electric metersof any locations and size and removing materials to store for keeping in safe custody or for taking credit maintaining proper records, reading of old meters, Make,ser no, date and time of removal and submitted to AGE E/M office, Complete all as specified and directed.
29Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition MAKE: L&T, Secure, Schnieder
30Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition. MAKE: L&T, Secure, Schnieder
31Supply and fix Desktop Computer 8 GB RAM, 1 TB HDD, Core i3 with HD Graphics 2000 17 inch monitor screen with key board and mouse with all electric and lan connection complete all as specified and directed at site.
32Supply and FixUPS- 1 KVA, with 2 nos 7.5 AH batteries, surge protection and 15 Mins backup complete all as specified and directed at site.
33Supply and fix Token printerwith print speed 90mm/sec paper width 57.5 + mm width 12 V DC power supply, USB cable etc with connected accessories complete all as specified and directed at site.
34Supply and Fix Report Printer - A4 Size, monochrome laserBlack and white complete all as specified and directed at site.
35Supply anf fix of 2 pair 2 Core telephone cable for Meter to In Home Display and 2.5 sq mm armoud copper cable from DG panel to each metering board
36Vending software - Installation Charges for Web based Vending system with provision of Hardware key, One day Training of the vending System, Tariff desinging and Customer Data Base definition for one Login
37Suuply and fix in repair new sheet metal enclosure for DB"S when MCBs to e used Triple pole and neutral ( TPN) 4 way double door complete all as specified and directed.
38Supply and fix in repair MCB(TPN) triple pole and neutral 415 V 63 Amps complete all as specified and directed. .Make : L&TBB40060B
39Supply and fix in repair sheet metal enclosure double door 8 way DBs SPN, 240V with 200 Amps rated bus barsdouble door complete all as specified and as directed.
40Supply and fix in repair MCB SPN40 to 63 Amps, 240 volts complete all as specified and as directed.Make : L&T BB20400B
41Supply and fix in repair MCB SP 5 to 32 Amps, 240 volts complete all as specified and as directed.Make : L&T BB10320B
42M & L in repair sub main wiring with 4 single core, 10 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 10 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals completeall as specified and directed. Note :- (i) Four runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length.
43M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals completeall as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length.
44Bi-Annual charges for Vending Services (Per consumer Meter)
45Note: Amount of sch of credit of Rs.26,660/-will be deducted from total amount of BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail