Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #28948024

Construction And Commissioning Of Tube Well At Various Villages Under Division Falna (Annual Rate Contract)

Issued by Government Departments · Falna, Rajasthan
Tender Value
90 Lakhs
Estimated cost
Bid Submission
02 Sep 2021
0 days left
EMD
1.80 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Falna → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction And Commissioning Of Tube Well At Various Villages Under Division Falna (Annual Rate Contract)

BOQ

Name of Work: Construction and Commissioning of Tubewell Under Division Falna(Rates are as per PHED TM Jaipur 2020)
Sl. No. Item Description
1Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc.byPercussion/rotary drilling method as per IS:1991 and IS:2800 part II:1979 ( both amended upto date) and technical specification, with gravel as per IS:4097-1967 and its packing as per IS: 2800 (part I & II) 1979 as amended up to date ( the work includes the cost of gravel & its primary Packing and packing during development, lowering of housing & Strainer for arresting fine sand particles and development work but excluding the cost of housing and strainer pipe assembly). The Work Would be Completed after obtaining sand free Water. Nominal Bore 150 mm dia
2Nominal Bore 200 mm dia
3Nominal Bore 250 mm dia
4Add 15 % extra on above item ( Item No 2.1.1 to 2.1.3) for drilling beyond 100 Mtr and Upto 200 Mtr. Rate Shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr
5Add 40 % extra on above item ( Item No 2.1.1 to 2.1.3) for drilling beyond 200 Mtr Rate Shall be applicable for only extra depth beyond200 mtr
6Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. Nominal bore 150 mm dia
7Nominal Bore 200 mm dia
8Add 15 % extra on above item ( Item No 2.3.1 to 2.3.2) for drilling beyond 100 Mtr and Upto 200 Mtr. Rate Shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr
9Add 30 % extra on above item ( Item No 2.3.1 to 2.3.2) for drilling beyond 200 Mtr Rate Shall be applicable for only extra depth beyond200 mtr
10Supply of EWR M.S. Black Casing Pipe ISI Marked ( IS:4270/2001) or amended up to date of following sizes. 150mm dia NB (Thickness of pipe 5.0mm & mass of tube 20.13kg/m)
11200mm dia NB(Thickness of pipe 5.4mm & mass of tube 28.46 kg/m)
12250mm dia NB(Thickness of pipe 7.1 mm & mass of tube 46.57 kg/m)
13Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-1985125mm dia nominal bore of 4.8mm thickness
14150mm dia nominal bore of 4.8mm thickness
15200mm dia nominal bore of 5.4mm thickness
16250mm dia nominal bore of 7.1mm thickness
17Supply & Installation of Singal Phase ISI Marked Submersible Motor Pump Set of three star better rating of BEE and as per IS:8034-2018 (Pump) and IS 9283-2013 (motor) as amended up to date of approved make of follwing duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, Installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains complete in all respect.upto 2.0 KW
18Above 2.0 KW
19Supply & Installation of 3Phase ISI Marked Submersible Motor Pump Set of three star better rating of BEE and as per IS:8034-2018 (Pump) and IS 9283-2013 (motor) as amended up to date of approved make of follwing duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, Installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains complete in all respect.Upto 5.5 KW ( 7.5 HP) & head up to 120 Mtr
20Upto 5.5 KW ( 7.5 HP) & head above 120 Mtr
217.5KW (10HP) & head up to 120 Mtr.
227.5KW (10HP) & head above 120 Mtr.
239.3KW (12.5HP) & head up to120 Mtr.
249.3KW (12.5HP) & head above120 Mtr.
2511 KW (15HP) & head up to120 Mtr.
2611 KW (15HP) & head above120 Mtr.
27Supply and Fixing of electic control feeder panel comprising of suitable rating MCCB, fully automatic star -delta starter, over load relay, ampere meter with CTs, volt meter,phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have spaqce for energy meter ( supplied by Discom). All these equipment shall be housed by panel box madeout from 18 gauge M.S. sheet with powder coating. Panel should be of minimum size 900 x 600 x 300 mm with stand (made of angle iron of size 35 x 35 x 5 mm) duly bolted/screwed with enclosure box having 4 legs, each legslength 18 \" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of cc plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 volt AC supply. up to 05.00 HP
28Supply and Fixing of electic control feeder panel comprising of suitable rating MCCB, fully automatic star -delta starter, over load relay, ampere meter with CTs, volt meter,phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have spaqce for energy meter ( supplied by Discom). All these equipment shall be housed by panel box madeout from 18 gauge M.S. sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with stand (made of angle iron of size 35 x 35 x 5 mm) duly bolted/screwed with enclosure box having 4 legs, each legslength 18 \" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of cc plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 volt AC supply. Above5.00 HP and up to 10.00 HP
29Above 10 HP and upto 15 HP
30Above 15 HP
31Supply and Fixing of ISI marked three corePVC flat cable as per IS 694-1990 or amended up to date and conductor as per class 5 of IS 8130-1980 including making connection etc. 3 core 4.00 sqmm
323 core 6 sqmm
333 core 10 sqmm
343 core 16 sqmm
35Supply & Fixing XLPE insulated ./ P.V.C. sheathed cable of 1.1 KV grand with aluminium condutor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cmsize trench 25cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc. as required of size.4 core 10.00 sqmm
364 core 16.00 sqmm
373.5 core 25.00 sqmm
383.5 core 35.00 sqmm
39Plate Earthing as per IS:3043 with G.I. Earth Plate of Size 600mm x 600mm x6.00mm by embodying 3 to 4 mtr below the ground level with 20mm dia. G.I. \"B\" Class watering pipe including all accessories like nut, bolts, reduce, nipple, wire meshed funnel and c.c finished chamber coveredwith hinged type with locking arrangement C.I Cover, C.I Frame of Size 300mm X 300mm complete with alternate layers of salt and coke/ charcoal, testing of earth resistance as required.
40Supply & Fixing MS Clamp set of 50x6mm flat from iron with nuts and bolts etc for holding the rise pipe assembly of submersible pump set.
41Supply and Fixing of tube well cover of M.S. sheet 8 mm thick at top and 5 mm thick 100 mm wide sheet around the edge so as to form a cap on the top end of casing pipe with GI nipple 45 cm long and two GI flanges at both end in 80 mm sizes passing through a hole in the centre of M.S. sheet. A 25 mm socket with end plug shall also be wlded over top plate ( as per drawing enclosed). A GI nipple having outside thread of size1/2\" ( for installation pressure gauge ) shall be provided and welded with 80 mm GI nipple near top plate nipple shall be provided with end plug. 125 mm
42150 mm
43200 mm
44250 mm
45Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 32 mm dia.
4650 mm dia
47Providing and Lowering in tube well ISI marked HDPEpipeas per IS : 4984:1995 amended upto date in PE 80 grade and class PN 10 of following dia Including HDPE/GI fitting and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect.40mm dia
4850mm dia
49Providing and Fixing of double flanged CI body, ISI marked NRV of approved make of following sizes 65 mm dia
5080mm dia
51Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four nos of superior quality and approved make, including interconnections complete job.1000 Litres Capacity
522000 Litres Capacity
53Fabrication & Fixing M.S. Stand of Specified class of angle iron L-Shaped of 50 mm size with four legs grouted by 300*300*300mm CC Block M-15 in the ground and all legs tied up with each Other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. Tank Complete in all Respect.

AI Tender Summary

OUR REF NO 28948024
AUTHORITY Government Departments
TENDER VALUE 90 Lakhs
LAST DATE 02-09-2021
Authority
Authority Name Public Health Engineering Department
Work Description Construction And Commissioning Of Tube Well At Various Villages Under Division Falna (Annual Rate Contract)
Basic Detail
Tender No NIT No 59/2021-22
Bidding Type Tender
Location
City Falna
State Rajasthan
Key Dates
Publish Date 23 Aug 2021
Submission Date 02 Sep 2021
Open Date 02 Sep 2021
Finance
Tender Value 90 Lakhs
Tender Fee 5000
EMD 1.80 Lakhs
Exemption Not Available
Document List
BOQ_423731.xls
Tendernotice_1.pdf
aeee7d94-40c4-4df3-a966-ab880c8a5d1c.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 23, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 02, 2021

Bid Opening Date

Technical bids will be opened and evaluated.