}

Supply Of Cable Multicore 2X0.5 Data For Bhel Ac Ecable Multicore 2X0.5 Data For Bhel Ac E, Screened Multicore Data Cable 2 X 0.5 Sqmm Shielded Twisted Pair + 1 X 0.5 Jacketed Cable For Kolkatta Metro Rolling Stock Applications For Communication Among Dif-Tamil Nadu

Integral Coach Factory-ICF has published Supply Of Cable Multicore 2X0.5 Data For Bhel Ac Ecable Multicore 2X0.5 Data For Bhel Ac E, Screened Multicore Data Cable 2 X 0.5 Sqmm Shielded Twisted Pair + 1 X 0.5 Jacketed Cable For Kolkatta Metro Rolling Stock Applications For Communication Among Dif. Submission Date for this Tender is 24-08-2021. Soldering and Welding Machinery Tenders in Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

28937387
Supply Of Cable Multicore 2X0.5 Data For Bhel Ac Ecable Multicore 2X0.5 Data For Bhel Ac E, Screened Multicore Data Cable 2 X 0.5 Sqmm Shielded Twisted Pair + 1 X 0.5 Jacketed Cable For Kolkatta Metro Rolling Stock Applications For Communication Among Dif
Open Tender
Indian
Tamil Nadu
24-08-2021

Tender Details

Supply Of Cable Multicore 2X0.5 Data For Bhel Ac Ecable Multicore 2X0.5 Data For Bhel Ac E, Screened Multicore Data Cable 2 X 0.5 Sqmm Shielded Twisted Pair + 1 X 0.5 Jacketed Cable For Kolkatta Metro Rolling Stock Applications For Communication Among Different Systems To The Following Specification. Technical Requirement: The Basic Requirement Is As Follows: 1 Pair Shielded Twisted Pair Jacketed Cable. The Cable Shall Have Not Less Than12 Twists Per Metre. Differential Characterestic Impedance Of Unloaded Line Shall Be 120 Ohm+ / - 10% For Sinusoidal Signal Of Frequency Between 0.75 Mhz To 3 Mhz. The Cross Sectional Area Of The Wire Shall Be Between 0.34 Sqmm ( Awg22 ) And 0.56Sqmm ( Awg20 ) . Cable Attenuation Shall Be Less Than 15 Db / Km At 1.5 Mhz And Less Than 21 Db / Kmat 3 Mhz. Differential Distributed Capacitance Of The Cable ( Wire To Wire ) Shall Not Exceed 46Pf / M At 1.5 Mhz. Capacitive Unbalance To The Shield Shall Not Exceed 1.5Pf / M At 1.5Mhz. Wherever Two Pairs Of Wire Are Carried In The Same Cable, The Signal Rejection From One Pair To Another Shall Be Superior To 45 Db In The Range From 0.75 Mhz To 3 Mhz. Transfer Impedence Of The Cable Shall Be Less Than 0.020 Ohm / M At 20 Mhz. Voltage Rating: 300 V Test Voltage : 2000 V Temperature Range: -40 Deg C To 90 Deg C. Nominal Cable Size ( N X Sqmm ) : 1 X 2 X 0.5 + 1 X 0.5 Conductor: Stranded, Tin Plated Copper To Bs 6360, Flexible Insulation: Dual Wall Insulation, Halogen Free, Flame Retardant To Iec 60332-3 ( Cat-A ) & Fire Resistant To Iec 60331 General Properties: Excellent High Temperature, Low Temperature, Ozone And Screen: Tin Plated Copper Braid. Weathering Resistance, Zero Halogen, Flame Retardant, Solder Iron Resistant Easily Strippable, Flexible Excellent Screening Properties.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item Description
1CABLE MULTICORE 2X0.5 DATA FOR BHEL AC E
2SCREENED MULTICORE DATA CABLE 2 x 0.5 SQMM SHIELDED TWISTED PAIR + 1 x 0.5 JACKETED CABLE FOR KOLKATTA METRO ROLLING STOCK APPLICATIONS FOR COMMUNICATION AMONG DIFFERENT SYSTEMS TO THE FOLLOWING SPECIFICATION. TECHNICAL REQUIREMENT: THE BASIC REQUIREMENT IS AS FOLLOWS: 1 PAIR SHIELDED TWISTED PAIR JACKETED CABLE. THE CABLE SHALL HAVE NOT LESS THAN12 TWISTS PER METRE. DIFFERENTIAL CHARACTERESTIC IMPEDANCE OF UNLOADED LINE SHALL BE 120 OHM+/- 10% FOR SINUSOIDAL SIGNAL OF FREQUENCY BETWEEN 0.75 MHz TO 3 MHz. THE CROSS SECTIONAL AREA OF THE WIRE SHALL BE BETWEEN 0.34 SQMM (AWG22) AND 0.56SQMM (AWG20). CABLE ATTENUATION SHALL BE LESS THAN 15 dB/KM AT 1.5 MHz AND LESS THAN 21 dB/KMAT 3 MHz. DIFFERENTIAL DISTRIBUTED CAPACITANCE OF THE CABLE (WIRE TO WIRE) SHALL NOT EXCEED 46pF/m AT 1.5 MHz. CAPACITIVE UNBALANCE TO THE SHIELD SHALL NOT EXCEED 1.5pF/M AT 1.5MHz. WHEREVER TWO PAIRS OF WIRE ARE CARRIED IN THE SAME CABLE, THE SIGNAL REJECTION FROM ONE PAIR TO ANOTHER SHALL BE SUPERIOR TO 45 dB IN THE RANGE FROM 0.75 MHz TO 3 MHz. TRANSFER IMPEDENCE OF THE CABLE SHALL BE LESS THAN 0.020 OHM/M AT 20 MHz. VOLTAGE RATING: 300 V TEST VOLTAGE : 2000 V TEMPERATURE RANGE: -40 DEG C TO 90 DEG C. NOMINAL CABLE SIZE(n x SQMM) : 1 x 2 x 0.5 + 1 x 0.5 CONDUCTOR: STRANDED, TIN PLATED COPPER TO BS 6360, FLEXIBLE INSULATION: DUAL WALL INSULATION, HALOGEN FREE, FLAME RETARDANT TO IEC 60332-3 (CAT-A) & FIRE RESISTANT TO IEC 60331 GENERAL PROPERTIES: EXCELLENT HIGH TEMPERATURE, LOW TEMPERATURE, OZONE AND SCREEN: TIN PLATED COPPER BRAID. WEATHERING RESISTANCE, ZERO HALOGEN, FLAME RETARDANT, SOLDER IRON RESISTANT EASILY STRIPPABLE, FLEXIBLE EXCELLENT SCREENING PROPERTIES.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail