| 1 | PROVIDING AND FIXING OIL & GREASE SEPERATION MANAGER (750MMX1000MM) |
| 2 | PROVIDING AND FIXING BAR SCREEN |
| 3 | PROVIDING AND FIXING EFFLUENT LIFTING PUMP |
| 4 | PROVIDING AND FIXING AIR BLOWER |
| 5 | PROVIDING AND FIXING MBBR - IMSFRP (2500MMX1500MMX3000MM) |
| 6 | PROVIDING AND FIXING MBBR - IIMSFRP (2500MMX1500MMX3000MM) |
| 7 | PROVIDING AND FIXING TUBE SETTLER MSFRP (1500MMX1500MMX2000MM) |
| 8 | PROVIDING AND FIXING CLEAR WATER TANK |
| 9 | PROVIDING AND FIXING FILTER FEED PUMP |
| 10 | PROVIDING AND FIXING MGF |
| 11 | PROVIDING AND FIXING ACF |
| 12 | PROVIDING AND FIXING PRESSURE GAUGE(12 NOS) |
| 13 | PROVIDING AND FIXING ELECTRICAL CONTROL PANEL |
| 14 | PROVIDING AND FIXING CABLE TRAY (10 feet length) |
| 15 | PROVIDING AND FIXING WATER PIPE LINE(20 FEET LENGTH) UPVC 1.5\"CLASS A |
| 16 | PROVIDING AND FIXING MS PIPE 1\" ( AIR PIPE LINE ) MEDIUM DUTY |
| 17 | PROVIDING AND FIXING VALVES |
| 18 | PROVIDING AND FIXING OIL & GREASE SEPERATION MANAGER (750MMX1000MM) |
| 19 | PROVIDING AND FIXING BAR SCREEN |
| 20 | PROVIDING AND FIXING CHEMICAL REACTION TANK (MSFRP-1000MMX1000MMX1000MM) |
| 21 | PROVIDING AND FIXING TUBE SETLER TANK (MSFRP-1500MMX1000MMX1000MM) |
| 22 | PROVIDING AND FIXING CLEAR WATER TANK |
| 23 | PROVIDING AND FIXING EFFELUENT LIFTING PUMP |
| 24 | PROVIDING AND FIXING SIDE CHANNEL BLOWER |
| 25 | PROVIDING AND FIXING FILTER FEED PUMP |
| 26 | PROVIDING AND FIXING MULTI -GRADE FILTER |
| 27 | PROVIDING AND FIXING ACTIVATED CARBON FILTER |
| 28 | PROVIDING AND FIXING PRESSURE GAUGE |
| 29 | PROVIDING AND FIXING ELECTRICAL CONTROL PANEL |
| 30 | PROVIDING AND FIXING CABLE TRAY (10 feet length) |
| 31 | PROVIDING AND FIXING WATER PIPE LINE(20 FEET LENGTH) UPVC 1.5\" CLASS A |
| 32 | PROVIDING AND FIXING MS PIPE 1\"MEDIUM DUTY |
| 33 | PROVIDING AND FIXING VALVES |
| 34 | HEMERA L600 HEMERAA L600 ONLINE WATER QUALITY ANALYSER- COD/BOD/TSS/PH |
| 35 | DATA TRASMISSION DATALOGGER WITH 1 YEAR DATA TRANSMISSION |
| 36 | INSTALLATION ACCESSORIES INCLUDES HUMIDITY PROOF PANEL, SAMPLE PUMP, 24 VDC 2.5A POWER SUPPLY |
| 37 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 38 | All kind of soil |
| 39 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 40 | All kinds of soil |
| 41 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 42 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 43 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 44 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) |
| 45 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 46 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 47 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 48 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 49 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 50 | Suspended floors, roofs, landings, balconies and access platform |
| 51 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 52 | Thermo-Mechanically Treated bars |
| 53 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete |
| 54 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 55 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 56 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 57 | Hot finished welded type tubes |
| 58 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 59 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 60 | Ridges plain (500 - 600mm) |
| 61 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 62 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 63 | 12 mm cement plaster: |
| 64 | 1:4 (1 cement: 4 coarse sand) |
| 65 | Neat cement punning. |
| 66 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 67 | 150 mm dia. R.C.C. Pipe |
| 68 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 69 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : |
| 70 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 71 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 72 | L D- 2.5 |
| 73 | Rectangular shape 600x450 mm internal dimensions |
| 74 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 75 | For pipes 100 to 250 mm diameter |
| 76 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 77 | Group B |
| 78 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 79 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 80 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 81 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 82 | SITC of HEAVY DUTY exhaust fan of 380 mm sweep 900 RPM with louver & shutter in the wall existing opening etc as reqd |
| 83 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 84 | 12 way , Double door |
| 85 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 86 | Single pole |
| 87 | Single pole and neutral |
| 88 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 89 | 3½ X 35 sq. mm (32mm) |
| 90 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick, including acessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoaal/coke and salt as required. |
| 91 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |