Supply And Installation Of Equipment For Department Of Physics , Physics , Set Up To Determine G And Velocity For A Freely Falling Body Using Digital Timing Technique , Set Up To Determine The Valueof G Using Bar Pendulum , Set Up To Compare Capacita
Tender Overview
Project Description
Supply And Installation Of Equipment For Department Of Physics , Physics , Set Up To Determine G And Velocity For A Freely Falling Body Using Digital Timing Technique , Set Up To Determine The Valueof G Using Bar Pendulum , Set Up To Compare Capacitances Using De’Sauty’S Bridge , Set Up To Verify The Superposition, And Maximum Power Transfer Theorems , Set Up To Study Response Curve Of A Series Lcr Circuit And Determine Its ( A ) Resonant Frequency, ( B ) Impedance At Resonance, ( C ) Quality Factor Q, And ( D ) Band Width , Set Up To Study The Response Curve Of A Parallel Lcr Circuit And Determine Its ( A ) Anti-Resonant Frequency And ( B ) Quality Factor Q , Set Up To Determine Stefan’S Constant Using Thermocouple , Set Up To Calibrate A Thermocouple To Measure Temperature In A Specified Range Using ( I ) Null Method, ( Ii ) Direct Measurement Using Op-Amp Difference Amplifier And To Determine Neutral Temperature , Set Up To Determine The Excitation Potential Of Mercury / Argon By Franck-Hertz Experiment , Set Up To Study Photo-Electric Effect: Photo Current Versus Intensity And Wavelength Of Light; Maximum Energy Of Photo-Electrons Versus Frequency Of Light , Set Up To Determine The Absorption Lines In The Rotational Spectrum Of Iodine Vapour , Set Up To Study Of V-I & Power Curves Of Solar Cells, And Find Maximum Power Point & Efficiency. , Set Up To Study The Characteristics Of A Bipolar Junction Transistor In Ce Configuration , Set Up To Investigate The Use Of An Op-Amp As An Integrator / Differentiator , Set Up To Measure The Dielectric Constant Of A Dielectric Materials With Variation Of Frequency , Set Up To Measure The Resistivity Of A Semiconductor ( Ge ) With Temperature By Four-Probe Method ( Room Temperature To 150 0C ) And To Determine Its Band Gap , Set Up To Determine The Hall Coefficient Of A Semiconductor Sample. , Set Up To Analyze Elliptically Polarized Light By Using A Babinet’S Compensator , Set Up To Determine The Wavelength And Velocity Of Ultrasonic Waves In A Liquid ( Kerosene Oil, Xylene, Etc. ) By Studying The Diffraction Through Ultrasonic Grating , Set Up To Determine The Refractive Index Of ( 1 ) Glass And ( 2 ) A Liquid By Total Internal Reflection Using A Gaussian Eyepiece , Set Up To Verify The Law Of Malus For Plane Polarized Light , Cathode Ray Oscilloscope ( 30 Mhz Dual Trace ) , Travelling Microscope , Function Generator , All In One Desktop Computer 10Th Gen, Intel Core I3-1005G1, 1.1Ghz 8Gb Ram, 512 Gb Ssd, 23.8 Inch Fhd Display….. Model:24-Dp0816in , All In One Desktop Computer Hp Omen Core I5 10Th Gen ( 8Gb / 512Gbssd…. , Equilateral Glass Prism For Spectrometer , Servo Stabiliser -10Kva Model:6346 , Servo Stabiliser - 5Kva Model: 6344 , Scanner Cum Laser Printer , Set Up To Determine The Band Gap By Measuring The Resistance Of A Thermistor At Different Temperature , Spectrometer-Dia:7 Inch; Vernier Constant:20Sec , Set Up To Study The Pe Hysteresis Loop Of A Ferroelectric Crystal , To Study The I-V Characteristics Of Zener Diode And Its Use As Voltage Regulator , Study Of V-I And Power Curves Of Solar Cells And Find Maximum Power Point And Efficiency , To Determine Plank’S Constant Using Leds Of At Least 4 Different Colour , Set Up To Study The Complete I-V Characteristics Of A Tunnel Diode , Set Up To Study Half Adder, Full Adder And Fourbit Binary Adder , Set Up To Study Half Subtractor , Full Subtractor, Adder-Subtractor Using Full Adder Ic , To Determine Self-Inductance Of A Coil By Anderson’S Bridge , To Study The Motion Of Spring And Calculate ( A ) Spring Constant, ( B ) G And ( C ) Modulus Of Rigidity , To Determine The Elastic Constants Of A Wire By Searle’S Method , Ac Milivoltmeter , Regulated Dc Power Supply , Regulated Dc Power Supply , Ballistic Galvanometer , Dead Beat Galvanometer , Digital Weighing Machine , Portable Type Pointer Galvanometer
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2021 | Corrigendum | Technical Bid | 28-Aug-2021 |
| 2 | 28-Aug-2021 | Date | Date | 31-Aug-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | PHYSICS |
| 2 | Set up to determine g and velocity for a freely falling body using Digital Timing Technique |
| 3 | Set up to determine the valueof g using Bar pendulum |
| 4 | Set up to compare capacitances using De’Sauty’s bridge |
| 5 | Set up to verify the Superposition, and Maximum power transfer theorems |
| 6 | Set up to study response curve of a Series LCR circuit and determine its (a) Resonant frequency,(b) Impedance at resonance, (c) Quality factor Q, and (d) Band width |
| 7 | Set up to study the response curve of a parallel LCR circuit and determine its (a) Anti-resonant frequency and (b) Quality factor Q |
| 8 | Set up to determine Stefan’s constant using thermocouple |
| 9 | Set up to calibrate a thermocouple to measure temperature in a specified Range using (i) Null Method, (ii) Direct measurement using Op-Amp difference amplifier and to determine Neutral Temperature |
| 10 | Set up to determine the excitation potential of mercury/Argon by Franck-Hertz experiment |
| 11 | Set up to study Photo-electric effect: photo current versus intensity and wavelength of light; maximum energy of photo-electrons versus frequency of light |
| 12 | Set up to determine the absorption lines in the rotational spectrum of Iodine vapour |
| 13 | Set up to study of V-I & power curves of solar cells, and find maximum power point & efficiency. |
| 14 | Set up to study the characteristics of a Bipolar Junction Transistor in CE configuration |
| 15 | Set up to investigate the use of an op-amp as an Integrator / Differentiator |
| 16 | Set up to measure the Dielectric Constant of a dielectric Materials with variation of frequency |
| 17 | Set up to measure the resistivity of a semiconductor (Ge) with temperature by four-probe method (room temperature to 150 0C) and to determine its band gap |
| 18 | Set up to determine the Hall coefficient of a semiconductor sample. |
| 19 | Set up to analyze elliptically polarized Light by using a Babinet’s compensator |
| 20 | Set up to determine the wavelength and velocity of ultrasonic waves in a liquid (Kerosene Oil, Xylene, etc.) by studying the diffraction through ultrasonic grating |
| 21 | Set up to determine the refractive Index of (1) glass and (2) a liquid by total internal reflection using a Gaussian eyepiece |
| 22 | Set up to verify the law of Malus for plane polarized light |
| 23 | Cathode Ray Oscilloscope (30 MHz Dual Trace) |
| 24 | Travelling Microscope |
| 25 | Function Generator |
| 26 | All in one Desktop Computer10th Gen, Intel Core i3-1005G1,1.1GHz8GB RAM,512 GB SSD,23.8 inch FHD Display…..Model:24-dp0816in |
| 27 | All in one Desktop ComputerHP Omen Core i5 10th Gen(8GB/512GBSSD…. |
| 28 | Equilateral glass Prism for spectrometer |
| 29 | Servo Stabiliser -10KVA Model:6346 |
| 30 | Servo Stabiliser - 5KVA Model: 6344 |
| 31 | Scanner cum Laser Printer |
| 32 | Set up to determine the band gap by measuring the resistance of a thermistor at different temperature |
| 33 | Spectrometer-Dia:7 inch; Vernier Constant:20Sec |
| 34 | Set up to study the PE hysteresis loop of a ferroelectric crystal |
| 35 | To study the I-V characteristics of Zener Diode and its use as voltage regulator |
| 36 | Study of V-I and power curves of solar cells and find maximum power point and efficiency |
| 37 | To determine Plank’s constant using LEDs of at least 4 different colour |
| 38 | Set up to study the complete I-V characteristics of a Tunnel Diode |
| 39 | Set up to study Half Adder, Full Adder and fourbit Binary Adder |
| 40 | Set up to study Half Subtractor , Full Subtractor, Adder-Subtractor using full adder IC |
| 41 | To determine self-inductance of a coil by Anderson’s bridge |
| 42 | To study the Motion of Spring and calculate (a) Spring constant, (b) g and (c)Modulus of rigidity |
| 43 | To determine the elastic Constants of a wire by Searle’s method |
| 44 | AC Milivoltmeter |
| 45 | Regulated DC power supply |
| 46 | Regulated DC power supply |
| 47 | Ballistic Galvanometer |
| 48 | Dead Beat Galvanometer |
| 49 | Digital Weighing Machine |
| 50 | Portable type pointer galvanometer |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender