Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Aug-2021 | Corrigendum 1 | Other | 06-09-2021 |
2 | 06-Sep-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-09-2021 |
Sl. No. | Item Description |
1 | Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying pipes or for other work in loose/soft soil complete |
2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete |
3 | Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete |
4 | Taking up existing CI/ DI Pipe water mains incl fittings and relaying, jointing and testing of same in to trenches in position after cleaning and removal of scale/blockage complete for the following sizes (Note- Lead joint shall be measured and paid separately) :- |
5 | 80 mm bore |
6 | 100 mm bore |
7 | Supply, laying, jointing and testing of CI/DI Pipe with spigot & socketed end, centrifugally cast, Class LA, with rubber ring/ jointing material, push on joint laid in trenches in old/ new route as required at site including taking down the old/ unsv pipe line complete all as specified & directed of following sizes (Make - Electrosteel / Jindal / Kesoram / IISCO / Electrotherm / Tata) (Note :Excavation and earth work shall be measured and paid separately under respective items of schedule) :- |
8 | 80 mm dia |
9 | 100 mm dia |
10 | 150mm dia |
11 | M&L for CI/DI fittings, ISI marked, bends (any type, radius & angle) tapers any type (straight, bend, increasing decreasing or double socket etc) tee piees, single branch, "Y" junction, double branch cross (socket & spigot or flanged) collars, caps & plugs for spigot socketed pipes upto 150 mm bore complete |
12 | M&L for run lead joint incl jointing material for CI/DI pipe for following sizes including burning & removing old lead joint complete :- |
13 | 80mm dia |
14 | 100mm dia |
15 | 150mm dia |
16 | M&L for heavy duty CI Sluice Valve of pressure class PN-1.6 type flanged and drilled at both ends, conferming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket including taking down old unserviceable valve from pipe line of both ends complete of following sizes |
17 | 80 mm dia |
18 | 100 mm dia |
19 | 150 mm dia |
20 | Cutting of existing CI / DI pipe for insertion of CI specials /valvesetc. all as required including dewatering of leakage water etc complete for the following sizes :- |
21 | 80mm dia |
22 | 100mm dia |
23 | 150mm dia |
24 | Refixing/ Relaying only GI pipe in position with all fittings after cleaning and removal of scale/blockages effectivelyincl taking out from trenches complete all as specified and directed forfollowing sizes (Note :Excavation and earth work shall be measured and paid separately under respective items of schedule) :- |
25 | 15 mm bore |
26 | 20 mm bore |
27 | 25 mm bore |
28 | 40 mm bore |
29 | 50 mm bore |
30 | 80 mm bore |
31 | Supply, laying, jointing & testing of GI Pipe, medium grade, including all fittings in old/new position, laid in trenches/ wallincluding taking down the old/unsv pipe line complete all as specified & directed of following sizes (Make- Jindal/ TATA/ BST) (Note :Excavation and earth work shall be measured and paid separately under respective items of schedule) :- |
32 | 80 mm dia |
33 | 50 mm dia |
34 | 40 mm dia |
35 | 25 mm dia |
36 | 20 mm dia |
37 | 15 mm dia |
38 | Drilling and tapping cast iron water mains (in position) for branch connections of 15 mm bore to 25 mm bore including necessary fittings and mild steel brackets complete |
39 | S&F in repair heavy duty flanged GI pipe 100 mm bore including GI flanged bend with nut bolt and washer complete |
40 | M&L for construction of brick masonary valve pit chamber including necessary excavation and earthwork, PCC, brick work,12 mm thick rendering in cement mortar 1:4 on internal surface of valve pitand mild steelsheet cover 3mm thick andmild steelangle iorn frame size 40 x 40 x 5 mm around of valve pit, locking arrangement with pad lock of size 50 mm brass, 6 leavers and key (Make : Godrej) complete including twocoat of synthetic enamel overa coat red oxide primer on steel surfacewith preparation of surface and including dismantling of existing valve pit complete all as specified & directed for following sizes (internal dimension) :- |
41 | Size 600 mm X 600 mm X 600 mm |
42 | Size 900 mm X 900 mm X 900 mm |
43 | Size 1200 mm X 1200 mm X 900 mm |
44 | M&L for preparing the surfaces of wall of pump house/OH/UG sumps of size 600x450 mm and applying one coat of synthetic enamel paint (bule/Black) and written on it in white paint as "Date of cleaning, Due date of cleaning, capacity of pump etc of letter not less than 35 mm height complete all as direceted |
45 | M&L for painting ofexisting Steel/RCC surface with one coat of Black/Blue colour synthetic enamelled paint including preparation of surfaces complete |
46 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint on existing steel/ RCC wall surface with synthetic enamelled paint complete |
47 | S&F in repair heavy duty Brass forged Ball valve, screwed down high pressure 25 Kg/Cm2 with iron handle, screwed both ends complete for the following sizes of pipes |
48 | 50 mm dia |
49 | 40 mm dia |
50 | 25 mm dia |
51 | 20 mm dia |
52 | 15 mm dia |
53 | S&F in repair direct on line starter 415 volt, 50 Hz with voltmeter, Ammeter, relay, timer and single phase preventor complete for following pump set capacity |
54 | 3 HP Pump Set |
55 | 7.5 HP Pump Set |
56 | S&F in repair CI non return valve, heavy duty, 100 mm dia, class PN-1.6 flanged end complete ) |
57 | Suppy only liquid chlorine suitable for water treatment by mannual methed HDPF in 50 litre drum (Make : Davis Chemical/ Prothamesh Trading/ Aditya birla) (Note :- Fresh lot of liquid chlorine shall be supplied with in 45 Days from the date of manufacturing as per monthy demand or as directed |
58 | Supply only bleaching powder Calcium Hypochloride minimum 32% cholorine as per IS-1065:1989 in 25 Kg Bag (Make : Raj/Cambal/DCM/Aditya Birla/Rajendra chemical/RS dye/Kalyani/Guru Kirpa Traders) (Note :- Fresh lot of bleaching powder shall be supplied with in 45 Days from date of manufacturing as per monthy demand or as directed) |
59 | S&F in repair battery brass terminal heavy duty type for positive/ negative pole of lead acid battery |
60 | S&F in repair battery lead of copper conductor cable 50 sqmm X 1 mtr with lugs |
61 | S&F maintenance free Lead Acid battery, 12 Volt,180 AH, 25 Plates complete |
62 | M&L for replacementofindustrial copper conductor submersible cable, PVC insulated and PVC sheathed cable, 1100 volt grade of size 4 sqmm x 3 core |
63 | Taking up submersible pump setupto 7.5 HP with MS column pipe from borewell and lowering the same after repairing with electric connection complete all as directed |
64 | M&L for replacement of heavy duty MS column pipe, 50 mm dia, 3 m long flanged welded complete |
65 | Cleaning of underground/semi underground sump by taking out all sludge, silt from bottom and cleaning all inside walls with wire brush and brooming the walls and top ceiling/roof including washing the walls with fresh water mixed with bleaching powder and draining out complete sludge, silt etc from bottom of the sump and applying one coat of lime wash for the UG sump of capacity 50,000 gallons complete all as directed |
66 | All as per item No. 29 above but for the UG sump capacity 25,000 gallons |
67 | Cleaning ofRCC OH tank, by taking out all sludge, silt from bottom and cleaning all side walls with wire brush and brooming the walls and ceiling/roof including washing the walls with fresh water with bleaching powder and draining out complete sludge, silt etc from bottom of the tank and applying one coat of lime wash inside complete for walls and roof/ceiling of 12 mtr approx staging for the following capacity :- |
68 | 1,00,000 gallons |
69 | 50,000 gallons |
70 | S&F in repair CI pipe 150mm dia class "B",ISI marked centrifugally cast plain end and cut to required length, fixed in existing water pumping /Hydrant line complete (Note :- Lead joint and CI specials shall be measured and paid separetely) |
71 | S&F in repair of heavy duty stainless steel fore headedhydrant valve double headed of size 63 mm dia including nut,bolt complete (Make : Tirupati/Chhavi/JP fire/Swati/MK fire/Galant solutions/Shriram) |
72 | M&L in repair for three layer PPR (Poly propylene random) copolymer 32 mm dia concealed pipe SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold RO water supply with PPR plain (Brass threaded) fittings laid in trenches.. |
73 | M&L in repair heavy duty PPR gate valve (Brass insert) ISI marked for 32mm dia PP-R pipe |
74 | M&L for PCC 1:4:8 (Type D-2 ) with 40 mm graded stone for path/floor/foundation as directed complete |
75 | M&L for RCC (1:2:4 ) Type B-2 in 20 mm graded stone for path/floor/foundationcomplete (Note- TMT bar will be measured & paid seperately) |
76 | M&L for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Iron strip of size 32 x 6 mm as earthing lead(upto the body ofthe equipment) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil complete all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and directed |
77 | Supply & installation in repair of Sewage submersible pump of capacity upto 7.5 HP, three phase, 415 volt, 2800/2900 RPM including all connection and testing complete all as specified & directed |
78 | Supply, installation, testing & commissioning LT distribution cubical panel outdoor type, double door with rigid hinges, door handle locking arrangement back side openable, compartmentalized design, mounted on suitable PCC blocks, fabricated out of CRCA sheet 3mm thick, suitably spaced, totally enclosed in chamber for reception of 3 phase, 440 volt, 50 HZ, AC supply including all connection with aluminium strips, internal wiring with suitable size of PVC copper conductor wire with lugs panel shall be effectively PVC gasketed and sealed, glands to be provided at cable entries, powder coated painting and sign writing for in/out going connections and bottom support by MS channel MC-75 grouting in PCC 1:2:4, height 450 mm from ground level complete all as specified and directed and comprising of following [Note - (i) Make of LT Panel : Siemens/L&T/ABB/Schneider/Havells/Universal) (ii) Make of MCCB/MCB/Contactor - Schneider/ABB/L&T/Legrand/havells)] :- |
79 | 4 Nos bus bars of high conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 300 amp rating and 1 No for neutral rating 150 amp, mounted on DMC support with heat shrink sleeve - 01 set. |
80 | MCCB 4 pole, 160 amp, 415 volts, 25 KA - 01 No (Incoming) |
81 | MCCB 4 pole, 100 amp, 415 volts, 25 KA - 02 No(incl standby-01) (Outging) |
82 | MCCB 4 pole, 63 amp, 415 volts, 25 KA - 03 Nos (Outging) |
83 | Indication lamp (R,Y,B),LED type - One set of three |
84 | M&L forreplacement of cast iron impeller and steel shaft of centrifugal pump 40/30 HP including dismantling, opening and refixing the same on its original location all as specified and directed. |
85 | Dismantling of 7.5 HP pump set from rusted base frame and refixing the same on new base frame complete (Note : MS base frame will be measured & paid seperately) |
86 | M&Lfor replacement of MS channelbase frame fabricated by MS channel (MC-100) including civil work and grouting the same in PCC (1:2:4)with existing size/ make suitable for 7.5 HP pump complete |
87 | Supply & installation in repair of centrifugal pump having discharge not less than 28 m3/hr,Head-28 m,1400/1500 RPM suitable for 7.5 HP motor ,three phase, 415 volt including all connection and testing complete all as specified & directed |
88 | S&F in repair of good quality tyre rubber coupling (No.TC/0/015-2913 DE) suitable for 40 HP / 30 HP pump set |
89 | S &F in repair of good quality tyre rubber coupling (No. TC/P/014-2514-PX) suitable for 40 HP / 30 HP pump set |
90 | S &F in repair of good quality tyre rubber coupling (No. TC/5/011-2004-GN) suitable for 7.5 HP pump set |
91 | Dismanltingand disconnectionelectrical and water connection of thepump and transport to work shop & opening carefully and servicing complete with replacing of bushes, gland packing, ball bearing, rubber gasket, nut and bolt and re-fixing it in original position and making out all electrical and water connection incl painting to two coats with synthetic enamell paint after necessary prepartion incl testing & commissioning complete for following capacity :- (Note :- Replacement of impellor rewinding of motor shall be measured and paid separately) |
92 | 15 HP |
93 | 7.5/10 HP |
94 | 30/40 HP |
95 | M&L for rewinding of submersible motor with PVC insulated copper winding wire of existing gauge and size for following capacity. :- |
96 | Upto 3 HP |
97 | From 5 HP to 7.5 HP |
98 | M&L for rewinding of electrical motor, 3 phase with super enamelled copper winding wire/ PVC insulated copper winding wire of existing gauge and size to get proper speed and load with removing burnt winding wire for following capacity of motor :- |
99 | 7.5/10HP |
100 | 30/40 HP |
101 | M&L for Servicing of DG set, 3 phase, 320KVA capacity, 415 volt, 50 Hz of Make- Cummins with replacing the air filter, diesel filter, super by pass filter, lubricating filter,heavy duty coolant,15W40 lubricating oil(Make-HP/castrol/Valvoline/CAT) , fuel pipe with bengo bolt, hose pipe complete set and vent housing with clamp incl servicing and cleaning of radiator & diesel tank as per manufacturer instructions incl testing after repair & servicing complete all as specified and directed . (Note:- Servicing of DG set shall be valid for 6 months or 250 Hrs which is earlier) |
102 | S&F electronic battery charger, 24 Volt of DG set 320/400 KVA, 415 Volt, 50 Hz |
103 | M&L for Servicing of DG set, 3 phase, 400 KVA capacity, 415 volt, 50 Hz of Make- Greaves Cotton with replacing the air filter, diesel filter, super by pass filter, lubricating filter, heavy duty coolant,15W40 lubricating oil (Make-HP/castrol/Valvoline/CAT), fuel pipe with bengo bolt, hose pipe complete set and vent housing with clamp incl servicing and cleaning ofradiator & diesel tank as per manufacturer instructions incl testing after repair & servicing complete all as specified and directed .(Note:- Servicing of DG set shall be valid for 6 months or 250 Hrs which is earlier) |
104 | M&L for replacement of Electronic AMF Gen Set Controller Display Board(Model No EMS927V4/4083935) with digital card and programming complete suitable for 400/320 KVA DG set of Make-Greaves including connection and testing complete all as directed |
105 | M&L for Servicing of DG set, 3 phase, 63 KVA capacity, 415 volt, 50 Hz of Make-Crompton Greaves /Mahindra & Mahindra with replacing the air filter, diesel filter, super by pass filter, lubricating filter,heavy duty coolant,15W40 lubricating oil (Make-HP/castrol/Valvoline/CAT), fuel pipe with bengo bolt, hose pipe complete set and vent housing with clamp incl servicing and cleaning ofradiator & alternator assembly & diesel tank as per manufacturer instructions incl testing after repair & servicing all as specified and directed (Note:- Servicing of DG set shall be valid for 6 months or 250 Hrs which is earlier) |
106 | M&L for replacement of following spare parts of 63 KVA DG set, 415 volt of Make Mahindra & Mahindra :- |
107 | Electronic AMF Gen Set Controller Display Boardwith digital card and programming complete. |
108 | Hours meter |
109 | AMF panel relay including wiring complete. |
110 | M&L for Servicing of DG set, 3 phase, 30 KVA capacity, 415 volt, 50 Hz of Make-Ashok leyland with replacing the air filter, diesel filter, super by pass filter, lubricating filter,heavy duty coolant,15W40 lubricating oil(Make-HP/castrol/Valvoline/CAT), fuel pipe with bengo bolt, hose pipe complete set and vent housing with clamp incl servicing and cleaning ofradiator & alternator assembly & diesel tank as per manufacturer instructions incl testing after repair & servicing all as specified and directed .(Note:- Servicing of DG set shall be valid for 6 months or 250 Hrs which is earlier) |
111 | M&L for replacement of following spare parts of 30 KVA DG set, 415 volt |
112 | Solenoid switch ,12 volt |
113 | fuel pump |
114 | Starting switch assemblywith electric connection complete |
115 | S&F in repair motor relay suitable for high pressure pump 3 HP, 230 volt |
116 | S&F pump capacitor 50 MFD, 440 Volt |
117 | S&F pump capacitor 25 MFD, 440 Volt |
118 | M&L for black flexible rubber hosepipe 50 mm dia, ISI Marked |
119 | M&L for stainless steel wire rope (ss-304) size 8 mm dia with 2 nos holding clamps suitable for hanging of sewage submersible pump complete all as directed |
120 | S&F in repair pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete |
121 | M&L in repair steel work of tubular pipes (medium weight) including embedding in concrete and screwing etc posts and struts in fencing including cutting tops to shape as directed, drilling holes motching for wire etc flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
122 | S&F in repair chequered plate, angle iron, beam and channel sections of required size with flange plates caps, bases splices, angle brackets, cleats and other connections and conforming to Fe-410-W (Gde-E-250) quality "A" including taking out old/damaged PCC cover complete |
123 | M&L for cutting of road/path (width-25 cm x 40 cm) for laying of pipe line and making good to disturbed road/path including provision of PCC 1:2:4 type B-1 using 20 mm graded stone aggregate all as specified |
124 | M&L for spray painting of complete water pumpset of cap 7.5 to 40 HP with two coats of synthetic enamelled paint of specified colour after preparation of surface |
125 | M&L for spray painting of accoustic enclosure canopy of DG set of any capacity 30 to 400 KVA complete with two coats of synthetic enamelled paint of specified colour after preparation of surface complete |
126 | S&F in repair Vibration Pad suitable for DG set any capacity as directed |
127 | M&L in repair for rotating rectifier assembly plate with diodes,12 Volt, suitable for capacity of 320/400 KVA DG Set |
128 | M&L for Servicing, descaling and tungsten welding of solar water heater of capacity upto 200 LPD complete all as directed |
129 | S&F in repair of solar water heating element, 3 KW, 230 Volt incl connection complete |
130 | S&F in repair evacuated glass tube with existing size of solar water heater of capacity upto 200 LPD |
131 | S&F in repair of stainless steel (SS -304) inner tank wallthickness not less than 0.7 mm of solar water heater 200 LPD complete |
132 | S&F in repair of outer tank wall thickness not less than 0.5 mm of solar water heater upto 200 LPD complete |
133 | Supply only high range Chlorine Test Kit with coloured sample complete with all testing fitment and OT solution in plastic finish box complete |
134 | Supply only Total Hardness Test Kit (5-1000 Mg/L) with coloured sample with all testing fitment and OT solution in plastic finish box complete |
135 | M&L for painting of water supply pipes networks of 80/100 mm dia consisting of valves any type/ size at various pump houses inlcuding duly scrapping thoroughly the existing corroded paint / dirt/ dust / rust and preparing the surface and applyingtwo coats of syntheticenamel paint over a coat of red oxide primer asper the colour code and marking the water flow directions on pipe lines as directed. |
136 | M&L in repair auxiliary contactor 415 Volt, 18/20 amps, coil voltage 230 Volt including auxiliary block (1 NO + 1 NC) and over load relay complete |
137 | S&F MCCB 4 Pole, 415 volt of following capacity on existing panel including removing old one complete |
138 | 250 amps, 25 KA, adjustible type |
139 | 200 amps, 25 KA, adjustible type |
140 | 125 Amps, 25 KA, with thermal magnetic relase |
141 | Collecting water sample in clean bottle from borewell/ UG sump/service tank and getting Chemical, Boilogical, Potability Testing of water sample (as per IS 10500:2012) at Govt recognised/approved institute/Lab for potability and chemical analysis complete all as specified & directed |
142 | S&F in repairs for informatory/eqpt history/ installation sign board of size not less than 1200 x 900 mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame 40x40x5 mm thick , back ground and epqt history with high intensity prismatic reflective tape as specified colours (blue and white) with legs of sign board made out of heavy duty mild steel square pipe size 40x40mm and grouting with PCC (1:2:4) 20mm graded aggregate complete |
143 | S&F in repair 3 pole power contactor, type MNX-32 with coil voltage 230 Volt incl connection complete |
144 | S&F in repair front mounting add-on auxiliary contact block with 1 NO+1 NC suitable for MNX contactor 32/40 amp |
145 | All as per item above but with 2 NO+2 NC |
146 | S&F in repair bolted fuse link type HG, 4 amp size F-1 |
147 | S&F in repair heavy duty electric motor terminal block 70 amp, 415 Volt for 40 HP/ 30 HP motor complete |
148 | S&F in repair heavy duty electric panel mounted terminal block 40 amp, 2 row, 4 way complete |
149 | S&F in repair din type terminal block 16 amp, 2 row, 12 way complete |
150 | S&F heavy duty GI pipe 40mm bore with heavy duty GI socket and taking up old pipe alongwith submersible pump set of any capacity from borewell and lowering the same complete all as directed |
151 | Cleaning of sewage well/sump of size 3.50 mtr dia X 06 mtr depth, by taking out all sludge, silt from bottom and cleaning all inside walls with wire brush and brooming the walls and top ceiling/roof including washing the walls with fresh water mixed with bleaching powder and draining out complete sludge, silt etc from bottom of the sump and applying one coat of lime wash ar inside wall of sump complete all as directed (Note : All T&Ps shall be arranged by the contractor and cost of the same is deemed to be included in quoted rate) |
152 | All as per item No 92above but for sewage well/sump of size 2.00 mtr dia X 06 mtr depth |
153 | M&L for PCC 1:2:4 (Type B-1) with 20 mm graded stone for roof, curves, mud stops, rounded, champhered edges, floor et complete |
154 | M&L for MS TMT bar 10mm dia, cut to length, bent to shape as required incl cranking, bending with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed |
155 | Demolition of cement concrete (unreinforced/reinforced) of any type incl removal of same from site & thrown out where directed |
156 | M&L for brick work with sub class "B" bricks straight or curved on plane exc 6 mtr mean radius built in CM (1:4) incl demolition of old brick work incl removal & thrown out of same from site where directed |
157 | M&L for 15mm thick plaster in cement mortar 1:4 of fair face of brick work or concrete surface even & smooth, neeru finish incl taking down old cement plaster |
158 | M&L in repair of base frame for 40 HP/30 HP pump set made out of MS channel MC 125 & mounting fabricated by MS channel MC 100 to match with existing frame in size & shape incl dismantling & taking down pump set and re-fixing the same on new base frame complete all as directed (Note : MS work will be paid measured & paid seperately) |
159 | S&F in repair of electronic timer ST 100 for starter of pump set complete |
160 | M&L for replacement of asbestos gland rope of required size for water pumps complete |
161 | S&F in repair of GI strip size 25X4 mm thick incl shaddle, to be fixed on pillar/dome of OH tank as directed |
162 | Repair/maint and servicing of RO system ,700/1000 LPHincluding RO antiscalantchemicalto prevent scaling of RO membrane & replacement ofmicron filters,carbon filters,UV filters etc.all as directed. Note:- Servicing shall be done monthly for RO system and rectify the minor/major defects noticed immediately . |
163 | S&F in repair high pressure membrane suitable for RO plant of capacity 700/1000 LPH all as specified and as directed. |
164 | M&L for replacement of rotameter of commercial RO plant of capacity 700/1000 LPH. |
165 | S&F in repair of conventional type pressure gauge for monitoring of flow, 0-20 kg/cm2, 100mm dia complete all as specified and directed |
166 | M&L for replacement of gravels, pebbles & fine sand in sand filter of commercial RO plant of capacity 700/1000 LPH all as specified & directed |
167 | S&F in repair of multi port valves fixed at sand filter and carbon filter all as specified and directed (Make as per sample) |
168 | S&F in repair antiscalant chemical dosing pump of plastic body 10 LPH capacity,manually operated,having user friendly knob for adjusting dosing frequency, strainer & controller for chemical flow,double ball NRV ,CE certified,IP-65incl inlet & outlet flexible pvcpipes all as specified & directed |
169 | M&L for replacement of iron removal water filter with FRP body, 230 volt AC, capacity upto 1000 LPH,flow rate 0-5 m3/hr, treat iron upto 5 ppm size 1665 mm,manually operated alongwith inlet 7 outlet connection complete all as specified & directed |
170 | M&L for replacement of feeding pump set, monoblock type, 1 HP, 240 Volt, 2800 RPM complete for 1000/700 LPD RO plant |
171 | S&F in repair CI /DI heavy duty high pressure double air release valve 100 mm dia flanged ends all as specified and directed |
172 | M&L for painting of OH tank of capacity 1 lakh gallon upto 15 m staging heightwith Apex paint of make Asian/Burger/Dulko including scrabbing of old paint and making smooth the surface complete all as directed (Note - Cost of required T&P shall be included in the quoted rate) |
173 | M&L for painting of OH tank of capacity 50000 gallon upto 15 m staging heightwith Apex paint of make Asian/Burger/Dulko including scrabbing of old paint and making smooth the surface complete all as directed (Note - Cost of required T&P shall be included in the quoted rate) |
174 | S&F in repair rubber gasket 3mm thick with holes forflanged pipe/sluice valve of size 80 to 150 mm dia to avoid leakage all as specified and as directed |
175 | S&F in repair of MS nut bolt of any size with washer completeall as specified and as directed |
176 | M&L in repair micro hepa filter of size 610x610x300mm frame made out of aluminium sheet 22 gauge with aluminium mesh, filter efficiency not less than 99% suitable for air born pollution particles >0.3 micron complete all as directed |
177 | M&L in repair pre-filter of size 610x610x50mm frame made out of aluminium sheet 22 gauge with aluminium mesh, filter efficiency not less than 90% suitable for air born pollution particles >10 micron complete all as directed |
178 | M&L in repair pre-filter of size 610x300x50mm frame made out of aluminium sheet 22 gauge with aluminium mesh, filter efficiency not less than 90% suitable for air born pollution particles >10 micron complete all as directed |
179 | M&L for machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size confirming to IS 15658-2006 of 60mm thick, M-35 grade complete all as directed |
180 | M&L for sand filling under floor including watering, consolidation complete all as directed |
181 | Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc including making good the disturbed surfaces to match with the existing complete |
182 | Taking down unserviceable main switches, DBs including MCBs, bus bars chambers etc from wall / existing main boards and removing from site complete |
183 | M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :- |
184 | One light point controlled by one switch |
185 | Oneceiling/exhaust fan point controlled by one switch |
186 | One socket outlet 5 Amps controlled by one switch on same board |
187 | One socket outlet 5 amps controlled by one switch on independent board |
188 | One bell point controlled by one bell push switch |
189 | All as per item No 124 above but wiring with 2.5sqmm copper wire and 1.5sqmm earth wire for socket out let 16 Amps on independent board |
190 | All as per item No 124 above but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor |
191 | M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- |
192 | One light point controlled by one switch |
193 | Oneceiling/exhaust fan point controlled by one switch |
194 | One socket outlet 5 Amps controlled by one switch on same board |
195 | One socket outlet 5 amps controlled by one switch on independent board |
196 | One bell point controlled by one bell push switch |
197 | One light point controlled by two 2-way switch |
198 | All as per serial item No 127 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire. |
199 | All as per item No.127above but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor |
200 | S&F Switch piano flush type 5/6 Amps single pole one way230 Volts complete |
201 | S&F Switch piano flush type 15/16 A single pole one way 230 Volts complete |
202 | S&F Socket Outlet 2 in 1, 3 pin 5 Ampsflush type 230 Volt complete |
203 | S&F Socket Outlet 2 in 1,3/6 pin 5 and 15 Amp flush type 230 Volts complete |
204 | S&F Switch piano flush type 15/16 Amps single pole, two way230 Volts complete |
205 | S/F Bell push, flush type 5 Amps 230 Volts complete |
206 | S&F electronic fan step regulator flush switch type 100/120 watt, 230 Volt complete |
207 | S&F ding dong bell, AC, 230 volts, single pole complete |
208 | S&F lamp holder, 230 volt AC, PVC / Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb inverter type upto 4 Hrs back up 6500 K complete all as specified & directed |
209 | S&F ceiling rose, 6 Amps, 250 volts, ACwith three terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete |
210 | S&F modular switch 6 Amps, one way, one module 240 volts complete |
211 | S&F modular socket, 3 pin 6 Amps,240 volts, 2 module complete |
212 | S&F modular switch 16 A, 1 module,240 volts complete |
213 | S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete |
214 | S&F modular Bell push 6 Amps, one module 240 volts complete |
215 | S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete |
216 | S&F sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps "C" curve, 240 Volt complete |
217 | M&L in repair for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia or higher size, concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete |
218 | All as per above but with 6 sqmm and 6 sqmm as earth wire |
219 | S&F MCB DB, single pole and neutralwith 200 Amps rated bus bar, 230 volts, glazed,double door type, IP-43,including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :- |
220 | 4 way |
221 | 8 way |
222 | 12 way |
223 | S&F loadline distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB63/100 Amps as incomer and MCB SP as out going complete all as directed |
224 | S&F MCB DP/SPN, 240 Volts, AC of breaking capacity 10 KA,"C" curve and connections by using suitable copper lugs complete of following rating :- |
225 | 63 Amps |
226 | 40 Amps |
227 | S&F MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, "C" curve and connection by using suitable copper lugs complete |
228 | S&F MCCB 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line DB & connection complete of following rating :- |
229 | 63 amps rating |
230 | 100 amps rating |
231 | Supplying and laying in replacement or fixing or passing through pipe, 1100 volts gradePVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circuler for the following size of cables :- |
232 | 16 Sqmm |
233 | 10 Sqmm |
234 | S&F in repair of switch piano, flush type, 5/6 Amp, single pole, one way, 230 volts complete |
235 | S&F in repair of socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, 230 volts complete |
236 | S&F in repair of switch piano flush type 15/16 Amp, single pole, one way, 230 volts complete |
237 | S&F in repair of socket outlet 2 in 1, 3/6 pin 5 and 15 Amp, flush type, 230 volts complete |
238 | S&F in repair of Bell Push, flush type, 6 Amp, 230 Volts |
239 | S&F in repair electronic fan step regulatorswitch fiush type 120 watt, 230 Volt complete |
240 | S&F in repair of modular switch 10 amps single pole one module, 230 volts |
241 | S&F in repair of universal moudlar socket ,10 Amps, 5 pin, 2 module, 230 volts |
242 | S&F in repair of modular switch 16/20 amps single pole one module, 230 volts |
243 | S&F in repair of modular socket 16/20 amps, 2 module, 230 volts |
244 | S&F in repair of modular bell push with indicator 6 amps, one module |
245 | S&F in repair of modular fan step regulator 120 watt 2 module , 230 volts |
246 | S&F in repair LED Bulkhead luminaire 10 watt of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection complete all as specified & directed |
247 | S&F in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection incl connection complete |
248 | S&F in repairwall mountedLED batten with aluminium housing and integrated electronic drive18/20 watt fixture 4 feet provided for efficient heat dissipation with polycorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete |
249 | S&F in repair surface and wall mounted LED batten 10 watt 2 feet longextruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete |
250 | S&F in repair wall mounting bracket decorative luminaire powder coated housing,SS finish fixture with opal glass diffuser suitable for GLS, B-22 lamp incl connection complete all as directed |
251 | S&F in repair LED recess mounted round down lighter luminaire with aluminium die cast housing 15/18 watt fitted in existing cavity of false ceiling |
252 | S&F in repair P-5, LED PLL Lamp, 18 watt, 230 volt for existing false ceiling G-11 base light fitting complete |
253 | S&F in repair highly efficient round shape downlighter 25 watt, 240 volt, CCT 5700 K with driver suitable for ceiling cutout 225 mm dia incl connection complete |
254 | S&F (in replacement) LED landscape bollard light 10 watt, 230 volt, inverted pyramid tripod type with soft 360 degree distribution, IP-65 protection, incl necessary civil work for grouting & foundation work of suitable size with PCC work complete all as specified and directed |
255 | S&F in repair 5 W LED T5 TL fitting (1ft) attractive wall mounted type suitable for mirror fittings, all accessories pre wired including up with twin core flat flexible copper conductor cable of suitable size complete all as specified and as directed. |
256 | S&F LED Bed side reading stainless steel wall light fitting 3/5 Watts,230 volt,AC, rectangular/round, flexible neck/Gooreneck, cool day light complete with all accessories incl connection complete (Make : As per sample as approved by GE) |
257 | S&F in repair surface/ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete |
258 | S&F in repair of LED linear surface/ suspended fittings, extruded aluminium body with opal polycarbonate diffuser, 38 watt, 4 ft long, CCT 6000 Kincl connection complete |
259 | S&F in repair LED energy efficientflood lightof 30 watt, 230 volt,anti glare diffuser ,IP-65 incl connection complete all as specified & directed complete |
260 | S&F in repairexhaust fan 300 mm sweep, 230V, AC, steel body with louver shutter etc complete and connection from ceiling rose to fan terminal incl cutting of hole at wall for required size and making good disturbed surface and depositing old fan to store yard complete all as directed |
261 | S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section complete |
262 | S&F electronic energy meter, current rating 10-60 amps, 240 Volt, AC, single phase, 2 Wire, accuracy Class 1.0, with LCD display incl/ fitted with temper proof meter box, weather proof, transparent, made out of FR polycarbonate, dust proof, good mechanical strength conforming to IS: 14772/2000,IP-65, size not less than 260 mm x 190 mm x 120 mm incl connection and depositing old meter to MES store complete all as directed |
263 | M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead(upto the body ofthe equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 40mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 ofSSR 1991(Part-I) complete |
264 | Taking down carefully electric geyser of any type and capacity bydisconnecting electric and water supply connection, opening nut, bolt, washer and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. (Note: Spare items shall be measured and paid seperately) |
265 | S&F geyser inner water tank 35/50Ltrs capacity steel body as per sample, duly tested complete all as specified and directed. |
266 | All as per above item but 25 Ltrs capacity |
267 | S&F heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete |
268 | All as per above itembut capacity 2 KW |
269 | S&F thermostat suitable for 50/35/25 ltrs capacity geysers |
270 | S&F Heavy duty hot water connection, SS rope threaded type with brassunions at both ends, 45cm long 15mm bore complete |
271 | S&F indicator lamp, Red/Green suitable for geyser of any type/capacity (Make as per sample) |
272 | S&F geyser base plate assembly of any type(having 6 or 9 hole) any model all as specified and directed complete (Make as per sample) |
273 | S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete |
274 | S&F in repair Plug top, 3 pin, 05 amps, 230 volt complete |
275 | S&F in repair Plug top, 3 pin, 15 amps, 230 volt complete |
276 | S&F in repair PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete all as specified and directed |
277 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete |
278 | S&F in repair LED solar street light fitting 40 watt, 6500 K with IP-65 protection incl bracket & connection complete all as specified and directed complete all as specified & directed |
279 | S&F in repair maintenance free lead acid battery 12 volt, 65 AH suitable for solar street light fitting incl angle iron frame/ stand made out of MS angle iron of size 40 x 5 mm incl connection complete all as specified & directed |
280 | Supply, installation & testing in repair 100 watt solar panel, output voltage 12 V, having 24 No of cells, size 110 cm X 65 cm incl necessary fittings complete all as specified and directed |
281 | S&F in repair of precast RCC earthing pit with CI cover ISI marked including angle iron frame made out of 35x35x4mm thick for supporting the edges of pit cover as dimension shown inElectrical plate No-2 of SSR part-I complete all as specified & directed |
282 | M&L for dismantling of unsv C/Fan of any make/model/sweep, cutting and removing the old defective/burnt winding, cleaning the core of fan motor and rewinding the fan motor with super enamelled copper winding wire of same gauge with insulating material and varnishing the core assembly, drying the moisture content to get appropricate speed and re-assemble the same complete all as directed (Note :- The cost of copper winding wire is deemed to be included in the quoted rate) |
283 | All as per above but for exhaust fan upto 300mm sweep size |
284 | All as per above but for exhaust fan of 380/450mm sweep size |
285 | S&F in repair capacitor 2.5/3.15 MFD suitable for C/fan incl connection complete |
286 | M&L in repair ball bearing suitable for any type/size/make of fan complete all as directed |
287 | M&L for taking down carefully window/split type Air conditioner 2/1.5 Ton capacity of any type/make from window/wall and removing front grills, air filters and cleaning, removing dust, washing and servicing with chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position complete all as specified |
288 | M&L for servicing of water cooler of any capacity, any type/make including disconnection of electric /water supply connectin and servicing with washing, removing dust and fixing its original position including electric and water connection complete |
289 | M&L for charging of refrigerant R-22 / R-410 or any other recommended refrigerant gas in 1.5/2 Ton window/split Air conditioner/ Refrigerator/ Deep Freezer/ Water Cooler any cap including detecting leakage and rectify the leakage with proper brazing and testing on full load complete |
290 | S&F in repair starting/running capacitor 55 to 80 MFD, 240 volt suitable for water cooler/window AC /split AC including connection complete |
291 | S&F in repair starting relay suitable for air conditioner 1.5/2 Ton/ Water cooler/Deep Freezer/ Refrigerator any cap complete |
292 | S&F in repair fan motor assembly of water cooler any cap of cooling capacity 40 to 80 ltr per hour including all accessories complete |
293 | S&F in repair magnetic contactor, 30 Amp FL 40 Amp, single pole, 208-240 V AC, 50/60 Hz for split/window air conditioner incl connection complete all as specified & directed |
294 | M&L for powder coating paint on water cooler/ refrigerator/ Deep freezer upto 310 ltr capacity including minor denting and welding as required complete |
295 | M&L for replacement of fan blower motor copper wound of window type air conditioner 1.5 /2 ton capacity with same rating 220/230 volt complete all as directed |
296 | M&L for replacement of fan blower motor blade of window type air conditioner 1.5 /2 ton capacity |
297 | S&F in repair Kit unit complete for window type AC of capacity 1.5 Ton excluding compressor but includingcondenser coil, evaporator coil, thermostat senser, a fan or blower, copper tubing, refrigerant control valve, digital PCB with remote, front grill etc complete all as specified & directed |
298 | S&F in replacement of thermostat switch suitable for window/split air conditioner, ISI marked of any make all as specified and directed. |
299 | S&F in replacement of thermostat switch with knob suitable for water cooler, ISI marked of any make/type capacity including making electric connection complete all as specified and directed. |
300 | M&L in repair copper tubing 1/2" dia with existing gauge for suction/discharge line of split air conditioner of 1.5 Ton/2Ton capacity including high quality puf insulation complete |
301 | All as per above itembut size 3/8" dia |
302 | S&F in repair outdoor unit suitable for 1.5 Ton split AC including rotary type compressor, high EER, copper material condenser unit, eco friendly refrigerent etc with all accessories complete in all respect all as directed |
303 | S&F in repair of cromium plated brass push cock 15mm dia, ISI Marked, for water cooler complete all as directed |
304 | S&F in replacement Motor single phase, 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete all as directed |
305 | S&F in replacement hermetically sealed rotary type compressor unitof capacity 1.5/2 T for split/window type AC and charging of adequate quantity of refrigerant gas and testing on completion complete |
306 | All as per above but for water cooler of any capacity/make |
307 | S&F in repair Power Circuit Board (PCB) suitable for split/ window type AC of capacity 1.5TR / 2.0 TR with all standard features i.e. power on-off, fan cooling speed, timer, temp etc complete all as directed |
308 | S&F in repair copper condensing unit of split air conditioning cooling coil unit 1.5/2 ton of any make complete all as directed (Charging of refrigerant will be measured and paid separately) |
309 | S&F in replacement of front grill of window type air conditioner 1.5 ton, any make/type complete all as directed |
310 | S&F in repair indoor unit suitable for 1.5 Ton split AC with PCB, LCD with temperature remote controller, noise level not less than 50 db etc with all accessories complete in all respect all as directed |
311 | S&F in repair wall mounting fan 400 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection and old to be deposited in store yard complete all as directed |
312 | S&F in repair pedestal fan 500 mm sweep with strong copper wound motor for better air delievery, smooth oscillation, superior low voltage performance, heavy base for stability, 3 speed control regulator, speed not less than 1400 RPM and old to be deposited in store yard complete all as directed |
313 | S&F 6mm thick plywood sheet (ISI marked), waterproof fixed in window of required size including cutting for passing air of desert cooler complete all as directed |
314 | S&F in repair plastic submersible pump suitable for desert cooler any size complete all as directed |
315 | S&F desert cooler pad (set of three) made out of wood wool etc for desert cooler any size complete |
316 | S&F in repair fan motor kit assembly of 500 mm sweep, single phase, not less than 145 watt, 230 volt, AC, 50 Hz, copper wound with blade for desert cooler complete all as directed |
317 | Repair /maintenance of Central & Package AC plantS&F in replacement of transformer of compressor 0-15 volt , 500 miliampere of 24 TR central AC plant. |
318 | S&F in repair transformer of compressor, 0-8 volt, 500 miliampere complete of 7.5 TR package type AC plant. |
319 | S&F in repair motorized mixing valve, actuator 3 way, 65 mm dia for chiller pumpwith 50 mm thick EPS insulation and 26 gauge aluminium cladding of central AC plantcomplete |
320 | M&L for repair control cable armoured with copper conductor 2.5 Sqmm x 2 core complete all as directed |
321 | M&L in repair control cable armoured with copper conductor 2.5 Sqmm x 3 core complete all as directed |
322 | M&L for replacement micro processor panel unit PMN single, 7-22 amps soft halt, 220 volt with display remote circuit, time relay and FRP cable complete for package type AC plant. |
323 | S&F in repair contractor 40 Amps, 3 pole, AC-3 rating complete of central AC plant |
324 | S&F in repair thermal overload relays range 3 to 5 ampsfor chillar pump |
325 | S&F in repair thermal overload relays range 9 to 15 ampsfor blower motor |
326 | S&F in repair thermal overload relay, range 0.3 to 0.5 amps ,MN-2 type complete. |
327 | S&F in repair heavy duty cast iron non return valve 80mm dia flanged type with 50 mm thick EPS insulation and 26 gauge aluminium cladding complete |
328 | S&F in repair of filter drier having 10 micron outlet filter ,100 % molecular sieve to maximize water absorption suitable for R-22/R-407C refrigerant all as specified and directed |
329 | M&L in replacement of condensing cooling fan motor, 1 HP, single phase with copper winding all as specified and directed |
330 | S&F in repair MCCB 160 Amp, 3 pole, 35 KA breaking capacity incl connection complete all as specified and directed |
331 | M&L for replacement of heavy duty ventilating fan, 600 mm sweep suitable for outdoor unit of package AC plant of 7.5 TR capacity, copper wound motor, 370 watt, 900 RPM, 230 volt, single phase, 50 Hz, permanently lubricated, insulation class B, including capacitor, 10 MFD, 440 volt with blade complete (Make: LAWKIM/Voltas/Blue star/siemens or equivalent make) |
332 | M&L for replacement of copper condensing /cooling coil with fin complete suitable for central/package type AC plant complete all as directed |
333 | S&F in repair of PCB with digital card of central AC plant 22 TR capacity including computerized programming of digital card with showing all connected features complete. |
334 | S&F in repair thermally protected commercial refrigerant compressor, 460 V3 (60 Hz), working voltage 380-400V 3 (50 Hz), maximum operating amp 35 A, suitable for R407C refrigerant for 22.7 TR central AC plant complete all as directed |
335 | Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 1,84,686.00 |
Copyright © 2022 · All Rights Reserved. Terms of Usage | Privacy Policy