Replacement And Up-Gradation Of Feeder Pillars At Various Locations And Ups Cable From Sub-Station No.3 To Admin Block At Nit Hamirpur Replacement And Up-Gradation Of Feeder Pillars At Various Locations And Ups Cable From Sub-Station No.3 To Admin Block
Tender Overview
Project Description
Replacement And Up-Gradation Of Feeder Pillars At Various Locations And Ups Cable From Sub-Station No.3 To Admin Block At Nit Hamirpur Replacement And Up-Gradation Of Feeder Pillars At Various Locations And Ups Cable From Sub-Station No.3 To Admin Block At Nit Hamirpur
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing MCCB of followingrating 4 pole 550 volt 50 HZ of Legrand-DPX3/Schneider-Acti9/Siemens-Betagard/Hager/L&T make.with megnato thermal release i/c drilling holes on the board connections earthing the body as required with two sets of spreaders of following capacitiesincluding entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 2 | 63 Amp. 16 KA |
| 3 | 100 Amp. 36 KA |
| 4 | 125Amp. 36 KA |
| 5 | 250 Amps 36 KA |
| 6 | 400 Amps 36 KA |
| 7 | Providing ,fixing (New )& replacement of (Old)outdoor stand mounted feeder pillar made of MS Sheet 1.6mm thick with suitable partition as per following.Feeder pillar must be spray painted to fine finish and should be properly fixed with masonary as required at site and must have sufficent clerance from ground for proper termination of incoming & outgoing cables as required & as perthe drawing supplied by the department complete including testing commissioning earthing cable termination etc. including entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 8 | Outside Electrical Engineering Department :- to accommodate IncommerMCCB 400 Amp. 4 pole 1 No., copper bus bar 4 strip 50x5mm, Aprox . 0.75 Mtr. long 1 No., Out going MCCB 400 Amp. 4 pole 1 Nos ,MCCB 100 Amp. 4 pole 1 Nos,with spare space for one no MCCB 250 Amps for future expansion complete with connections with copper strip of suitable size . |
| 9 | Outside Auditorium :- to accommodate IncommerMCCB 400 Amp. 4 pole 1 No., copper bus bar 4 strip 50x5mm, Aprox . 0.75 Mtr. long 1 No., Out going MCCB 400 Amp. 4 pole 1 Nos ,MCCB 100 Amp. 4 pole 1 Nos with spare space for one no MCCB 250 Amps for future expansion complete with connections with copper strip of suitable size . |
| 10 | Outside Mechanical Engineering Department :- to accommodate IncommerMCCB 400 Amp. 4 pole 1 No., copper bus bar 4 strip 50x5mm, Aprox . 0.75 Mtr. long 1 No., Out going MCCB 250 Amp. 4 pole 3 Nos , with spare space for one no MCCB 250 Amps for future expansion complete with connections with copper strip of suitable size . |
| 11 | Outside Chemical Engineering Department :- to accommodate IncommerMCCB 400 Amp. 4 pole 1 No., copper bus bar 4 strip 50x5mm, Aprox . 0.75 Mtr. long 1 No., Out going MCCB 400 Amp. 4 pole 1 Nos ,MCCB 250 Amp. 4 pole 1 Nos , MCCB 125 Amp. 4 pole 1 No, . |
| 12 | Near Guest House :- to accommodate IncommerMCCB 125 Amp. 4 pole 1 No., copper bus bar 4 strip 25x5mm, Aprox . 1 Mtr. long 1 No., Out going MCCB 100 Amp. 4 pole 2 Nos ,MCCB 63 Amp. 4 pole 1 Nos . |
| 13 | Near Type-IV A Block :- to accommodate IncommerMCCB 250 Amp. 4 pole 1 No., copper bus bar 4 strip 25x5mm, Aprox . 2 Mtr. long 1 No., Out going MCCB 125 Amp. 4 pole 4 Nos . |
| 14 | Providing ,fixing (New )& replacement of (Old )outdoor stand mounted feeder pillar made of MS Sheet 1.6mm thick with suitable partition and to accommodate IncommerMCCB 250 Amp. 4 pole 3 No., copper bus bar 4 strip 50x5mm, Aprox . 3 Mtr. long 3 No., Out going MCCB 63 Amp. 4 pole 8 Nos,MCCB 100 Amp. 4 pole 3 Nos ,MCCB 125 Amp. 4 pole 4 Nos 1 No, Bus Coupler 250 Amps 2 Nos, and space for 3 No MCCB,4 Pole 125 Amps .including digital volt meter and ammeter on all the three incoming feeders along wth indicating lamps complete with connections with copper strip of suitable size .Feeder pillar must be spray painted to fine finish and should be properly fixed with masonary as required at site and must have sufficent clerance from ground for proper termination of incoming & outgoing cables as required & as perthe drawing supplied by the department complete including testing commissioning earthing cable termination etc.including entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 15 | Providing dummy feeder pillar of size [ height 1000 mm xwidth 750 mm x depth 450 mm ]having legs 450mm height to lift the same from ground having suitable MS sheet arrangement inside to install contactors etc.including entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 16 | ProvidingPVC insulated and PVCsheathed, armoured/XLPE power cableof 3.5 core 70Sqmm size of Havells/KEI/CCI/Plaza, working voltage 1100 voltsincluding entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 17 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requiredincluding entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 18 | Above 35 sq. mm and upto 95 sq. mm |
| 19 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required including entire carrage of material in all leads, lifts, height and cost of all other incidentals. |
| 20 | 3.5 core 35 sq mm |
| 21 | 3.5 core 240 sq mm |
| 22 | 3.5 core 400 sq mm |
AI Tender Summary