Repair Replacement Of Lt Panels And Connected Items In Sqn Area And Ora At Ina Ezhimala As Per Boq And Tender Documents-1. Unsv Capacitor Duty Contactor 2. Unsv Apfc Relay 3. Unsv Capacitor Of Any Size 4. Unsv Ammeter / Voltmeter 5. Unsv Panel Of Any, EZHIMALA-Kerala

Military Engineer Services-MES has published Repair Replacement Of Lt Panels And Connected Items In Sqn Area And Ora At Ina Ezhimala As Per Boq And Tender Documents-1. Unsv Capacitor Duty Contactor 2. Unsv Apfc Relay 3. Unsv Capacitor Of Any Size 4. Unsv Ammeter / Voltmeter 5. Unsv Panel Of Any. Submission Date for this Tender is 06-09-2021. MCCB Tenders in EZHIMALA Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

28843171
Corrigendum : Repair Replacement Of Lt Panels And Connected Items In Sqn Area And Ora At Ina Ezhimala As Per Boq And Tender Documents-1. Unsv Capacitor Duty Contactor 2. Unsv Apfc Relay 3. Unsv Capacitor Of Any Size 4. Unsv Ammeter / Voltmeter 5. Unsv Panel Of Any
Open Tender
Indian
Kerala
EZHIMALA
06-09-2021

Tender Details

Repair Replacement Of Lt Panels And Connected Items In Sqn Area And Ora At Ina Ezhimala As Per Boq And Tender Documents-1. Unsv Capacitor Duty Contactor 2. Unsv Apfc Relay 3. Unsv Capacitor Of Any Size 4. Unsv Ammeter / Voltmeter 5. Unsv Panel Of Any Size 6. Unsv Contactor Of Any Type 7. Unsv Timer Of Any Type 8. Unsv Mcb Of Any Size 9. Unsv Mccb Of Any Size 10. Unsv Lt Cable Of Any Sizes

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-09-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF LT PANELS AND CONNECTED ITEMS IN SQN AREA AND ORA AT INA EZHIMALA
Sl. No. Item Description
1Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1.2m x 1.2 m x 0.6 m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
2(a) Busbar chamber (4 nos TP&N 400 amp rating) (Aluminium bus bar) SET 01 (with proper colour code). (b) Phase indicator LED lamp assembly- 03 No. (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT"s of suitable size. Panel should have separate chambers and busbar extensions to accomodate the following switch gears:- i) MCCB TPN 250 A as incomer - 01 No ii)outgoing MCCB 160 A - 02 Nos iii)MCB TPN 63 A -10 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes- 01 No Notes:- (a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separetly. (b) Panels shall beprocured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
3Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panelwith IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1.5m x 1.2 m x 0.6 m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include following accessories:-
4(a) Busbar chamber (4 nos TP&N 630 amp rating) (Aluminium bus bar) SET 01 (with proper colour code) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT"s of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 400 A as incomer - 01 No ii) Outgoing MCCB 250 A - 03 Nos iii) Outgoing MCCB 160 A - 01 Nos iii) MCB TPN 63 A - 6 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 01 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measuredand paid separately. b) Panels shall beprocured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
5Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panelwith IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1m x 1m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable sizeknockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
6(a) Busbar chamber (4 nos TP&N 630 amp rating)(Aluminium bus bar) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT"s of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 630 A as incomer - 01 No ii) Outgoing MCCB 250 A - 03 Nos iii) Outgoing MCCB 160 A - 01 Nos Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measuredand paid separetly. b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
7Repair/ replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panelwith IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1 m x 1.2 m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable sizeknockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
8(a) Busbar chamber (4 nos TP&N 400 amp rating) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colur code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01, with connected CT"s of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 250 A as incomer - 01 No ii) Outgoing MCCB 160 A - 01 Nos iii) MCB TPN 63 A - 8 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 01 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measuredand paid separetly. b) Panels shall beprocured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
9Repair/ replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panelwith IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1 m x 1 m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable sizeknockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include following accessories:-
10(a) Busbar chamber (4 nos TP&N 160 amp rating) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly -03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colur code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT"s of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 100 A as incomer - 01 No ii) Outgoing MCCB 63 A - 03 Nos iii) MCB TPN 32 A -4 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 02 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 02 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measuredand paid separetly. b) Panels shall beprocured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
11Supply and fix in replacement of MCCB 630 Amp 50 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
12Supply and fix in replacement of MCCB 400 Amp 36 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
13Supply and fix in replacement of MCCB 250 Amp 25 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
14Supply and fix in replacement of MCCB 160 Amp 16 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
15Supply and fix in replacement of MCCB 100 Amp 16 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
16Supply and fix in replacement of MCCB 63 Amp 16 KA/415volt rating four pole adjustable type complete all as specified and as directed.
17Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, "C" curve complete all as specified and as directed.
18Supply and fix in replacement of MCB 32 Amps TPN 240/415 Volts, "C" curve complete all as specified and as directed.
19Supply and fix in replacement of digital time switch day programme single phase complete all as specified and as directed by Engr in charge.
20Supply and fix in replacement of contactor four pole 415 volt 63 Amp MCX 12 complete all as specified and directed by Engr in charge.
21Repair/replacement of heat shrinkable type LT sleeves ofcapacity 1100V upto 1m length, suitable for cable size 16 to 50 sqmm complete all as specified and directed by Engr-in-charge.
22All as per item no 16 above but suitable for size 70 to 120 sqmm complete all as specified and directed by Engr-in-charge.
23All as per item no 16 above but suitable for size 150 and above complete all as specified and directed by Engr-in-charge.
24M&L for jointing LT straight through joint kit 1100 volt , size up to 70 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
25M&L for jointingLT straight through joint kit 1100 volt , size of 70 to 300 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
26Supply and fix in replacement of 05 kVAr (heavy duty)aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
27Supply and fix in replacement of 10 kVAr (heavy duty)aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
28Supply and fix in replacement of 15 kVAr (heavy duty)aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
29Supply and fix in replacement of 20 kVAr (heavy duty) aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
30Supply and fix in replacement of 30 kVAr (heavy duty)aluminium can type (gas filled) /squire typecapacitor 440 Volts complete all as specified and directed by Engr-in-charge.
31Supply and fix in replacement of 12.5 kVAr Capacitor Duty Contactor (0 No +01 NC) 440 Volts complete all as specified and as directed by Engr-in-charge.
32Supply and fix in replacement of 16.7 kVAr Capacitor Duty Contactor (0 No +01 NC) 440 Volts complete all as specified and as directed by Engr-in-charge.
33Supply and fix in replacement of 20 kVAr Capacitor Duty Contactor with auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
34Supply and fix in replacement of 25 kVAr Capacitor Duty Contactor with auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
35Supply and fix in replacement of 33.3 kVAr Capacitor Duty Contactorwith auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
36Supply and fix in replacement of 40 kVAr Capacitor Duty Contactor with auxilary contact (0 1No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
37Material and labour for servicing of LT capacitor panel outdoor / indoor type of any sizes including welding,cleaning, greasing and tightening of joint complete all as specified and as directed by Engr-in-charge.
38Material and labour for servicing of LT panel outdoor/indoor type of any sizes including welding,cleaning, greasing ,tightening of joint and minor patchings using weldings and rewiring complete all as specified and as directed by Engr-in-charge.
39Material and labour for rewiring of of LT panel/capacitor panel of outdoor/indoor type of any sizes including metering equipments, bus connectors and replacement of connector links and spreaders complete all as specified and as directed by Engr-in-charge.
40Supply and fix in replacement of APFC relay ,440 volt, as per existing site requirement of suitable make and model complete all as specified and as directed by Engr-in-charge.
41Supply and fix in replacement of surface mounted device LED indicator(Red,green,yellow), low power consumption,surge and low voltage glow protection as on site requirement complete all as specified and as directed by Engr-in-charge.
42Supply and fix in replacement of digital 3 phase ammeter of class 1440 volt, complete all as specified and as directed by Engr-in-charge.
43Supply and fix in replacement of digital 3 phase voltmeter of class 1440 volt, 8 stage complete all as specified and as directed by Engr-in-charge.
44Taking down the unserviceable LT UG cable of size of 95 to 300 sqmm 3.5 core/04 core including removing electrical connection and keeping side serviceable cable include removal of cable protection cover etc complete all as specified and as directed by Engr-in-charge.
45All as per item no 39 above but size up to 70 sqmm complete all as specified and as directed by Engr-in-charge.
46Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-charge. Note:- The excavation has to be done manually only.
47Returing and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engr-in-charge.
48Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from startingpoint complete all as specified and as directed by Engr-in-charge.
49Supply and spreading riddled earth for cushioningof the UG cable in trenches complete all as specified and as directed by Engr-in-charge. Note:- Punned thickness shall be measured for payment purpose.
50Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and as directed by Engr-in-charge. Note:- Contractor has to produce PCC cable cover test certificate from the manufacturer.
51Relaying of PCC un reinforced LTcable cover of size 250 mm x 150mm x40mm item obtained from ser no 39 & 40 complete all as specified and directed by Engr in charge.
52Supply andlaying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT 1100 volt grade with aluminium conductors of size 150 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
53All as per item no.47 above but size of 120 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
54All as per item no.47 above but size of 95 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
55All as per item no.47 above but size of 70 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
56All as per item no.47 above but size of 50 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
57All as per item no.47 above but size of 35 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
58All as per item no.47 above but size of 25 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
59Relaying cable obtained from taking out in trench/fixing to walls/pipe/pole with proper saddles XLPE insulated heavy duly galvanised steel strip armoured LT cablesize upto 70 sqmm3/3.5/4 core complete all as specified and as directed by Engr-in-charge.
60All as per item no.54 above but cable of size 95 to 300 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy