Construction Work Of A Building Near The Pravachan Hall For Establishing Basic Structures For The Successful Implementation Of Puja And Yatra Facility At Shri Kedarnath ( Electrical Work ) Construction Work Of A Building Near The Pravachan Hall For Esta, Kedarnath-Uttarakhand

Uttarakhand Char Dham Devasthanam Management Board has published Construction Work Of A Building Near The Pravachan Hall For Establishing Basic Structures For The Successful Implementation Of Puja And Yatra Facility At Shri Kedarnath ( Electrical Work ) Construction Work Of A Building Near The Pravachan Hall For Esta. Submission Date for this Tender is 27-08-2021. Electrical Maintenance Tenders in Kedarnath Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

28813114
Construction Work Of A Building Near The Pravachan Hall For Establishing Basic Structures For The Successful Implementation Of Puja And Yatra Facility At Shri Kedarnath ( Electrical Work ) Construction Work Of A Building Near The Pravachan Hall For Esta
Open Tender
Indian
Uttarakhand
Kedarnath
27-08-2021

Tender Details

Construction Work Of A Building Near The Pravachan Hall For Establishing Basic Structures For The Successful Implementation Of Puja And Yatra Facility At Shri Kedarnath ( Electrical Work ) Construction Work Of A Building Near The Pravachan Hall For Establishing Basic Structures For The Successful Implementation Of Puja And Yatra Facility At Shri Kedarnath ( Electrical Work )

Key Value

Document Fees
INR 4720 /-
EMD
Refer document
Tender Value
INR 71.01 Lakhs /-

BOQ Items

Name of Work:Construction Of Building near the pravachan hall under the construction of infrastructure for the successful operation of worship and travel arrangements in Shri Keadrnath Dham (Electrical Work)
Sl. No. Item Description
1LT PANELSupply, Installation testing & commissioning of medium Voltagesheet steel metal clad, compartmented cubicle Panel board.Shifting of panels from site store to the suitable location.Assembling and wiring of component supplied separately.Installation of panel in Electric room or as located in electrical drawings or as per site conditions, including removing packing etc.Earthing all components, frame etc. to a common internal earth bar.Connection, testing & commissioning.Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge.Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job.Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc.The rates for the distribution boards apart from the Breakers and instruments shall also include the following :This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings.Supporting rigid steel framework.Cubicle type, 14 gauge CRCAsheet steel enclosed.Proper bonding to earth.Painting/letteringon Breakers and distribution boards,the locationthey serve,providing on each panel its circuit diagram.Providing cable clamps / supports within distribution boards cable alley.TPN ACB’s / MCCB’sshall mean 3 pole ACB’s / MCCB’swith adequate size of neutral link.All MCB’s shall be of minimum 10 KA breaking capacity.Thebreakingcapacity of MCCB’s are mentionedpanelwise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise.All motor feeders MCCBs shall be of motor duty.Distributionpanels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.IP 54 for all Indoor panel.IP 65 and double door for all outdoor panel.AllMCCB’s shall be provided with operating mechanismfor door interlock.All measuring instruments (Meters) shall be of digital electronic with LED of approved makeAll hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.All panels shall have provision of the following:Pad locking of Switch board doors.Pad locking of MCCB’s handles in “OFF” Position.All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.SPD as shown in SLDAprooved Makes-L&T/ABB/schnider/Legrand/SIEMENS
2Supply, Installation,testingandcommissioning of IP 65 rated MAIN PANEL (FOR LIGHTING AND POWER) Having Incomer 160 Amp 20 KA FP MCCB (01 No) . Out Going 63 Amp FP 16KA MCB (04No), 40 Amp FP 16KA MCB (04No), 40 Amp DP 16KA MCB (01No), 25 Amp DP 16KA MCB (01No) & 80 Amp FP 16KA MCB (01No)
3Supply, Installation,testingandcommissioning of IP 66 rated Power APFC PANEL- 40 KVAR Having Incomer 80 Amp 25 KA FP MCB (01 No) Out Going 63 Amp TP 16KA MCB (01No) - 25 KVAR, 25 Amp TP 16KA MCB (03No) - 10 KVAR & 16 Amp TP 16KA MCB (02No) - 5 KVAR Capacitor Bank (01No. 25KVAR), Capacitor Bank (03No. 10KVAR) & Capacitor Bank (02No. 5KVAR)
4DISTRIBUTION BOARDS
5Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12way, Double door (IP43, IK09)
6Supply, Installation, Testing and commissioning of Timer having inbuilt contactor of 16A switching capacity (3600W), delay range setting, equivalent to Schneider CCT15225 / ABB / LEGRAND.
7Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09)
8Supply, installation, testing and commissioning "B" series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, "B" series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
9Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40A. Approved Makes-LEGRAND / SCHNIEDER/ SIEMENS / L&T / ABB
10Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
11Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
12Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
13Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
14MV CABLES, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
15Upto 35 sq. mm
16Above 35 sq. mm and upto 95 sq. mm
17Above 95 sq. mm and upto 185 sq. mm
18Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI
193.5C x 120 Sq.mm. Aluminum XLPE armored cable
203.5C x 95 Sq.mm. Aluminum XLPE armored cable
213.5C x 70 Sq.mm. Aluminum XLPE armored cable
223.5C x 35 Sq.mm. Aluminum XLPE armored cable
233.5C x 25 Sq.mm. Aluminum XLPE armored cable
244C x 16 Sq.mm. CU XLPE armored cable
254C x 10 Sq.mm. CU XLPE armored cable
264C x 6 Sq.mm. CU XLPE armored cable
273C x 10 Sq.mm. CU XLPE armored cable
283C x 6 Sq.mm. CU XLPE armored cable
29CABLE TERMINATION, Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI
303.5C x 120 Sq.mm. Aluminum XLPE armored cable
313.5C x 95 Sq.mm. Aluminum XLPE armored cable
323.5C x 70 Sq.mm. Aluminum XLPE armored cable
333.5C x 35 Sq.mm. Aluminum XLPE armored cable
343.5C x 25 Sq.mm. Aluminum XLPE armored cable
354C x 16 Sq.mm. CU XLPE armored cable
364C x 10 Sq.mm. CU XLPE armored cable
374C x 6 Sq.mm. CU XLPE armored cable
383C x 10 Sq.mm. CU XLPE armored cable
393C x 6 Sq.mm. CU XLPE armored cable
40INTERNAL WORKS, POINT WIRING, Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDBto respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points.Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approvedrigid FR PVC,conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmiumplatedmachine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring.Wire Size for Lighting circuitLighting circuit= 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board)From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E)Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E)Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly.Making of zari in wall using only electric cutter and finishing the surface as it was.earthing of fitting electrical connection to the fixture from the out let point/ceiling rose.Wire breaded PVC flexible conduit from ceiling point to light fixture.Supply and fixing of supporting frame, hardware and n/c tools and tacklesetc ForExhaust fan
41Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required- Group A
42light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plae and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,onnection, painting etc. as required. (For light plugs to be used in non residential buildings).
43power plug point modular type accessories:Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess,including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
44Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
45Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
46Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
47Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
48Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep.
49CONDUIT & OTHER, Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5025 mm
5132 mm
52EARTHING
53S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
54Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
55Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
56LIGHT FIXTURES
5720W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make BN021C LED20S PSU CW GR S2 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Makes-Philips/Wipro/K-Lite
5818W, 2000 Lumen Surface mounted LED Down light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Surface mounted LED Down light fixtures equivalent to Philips make SM251C LED20S complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Makes-Philips/Wipro/K-Lite
5918W, 2000 Lumen Recess mounted LED Down light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Recess mounted LED Down light fixtures equivalent to Philips make DN296B LED15S-6500 PSU WH complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Makes-Philips/Wipro/K-Lite
60Wall mounted LED Light :- Supply, Installation, assembling, connection, testing & commissioning of wall mounted LED Light suitable for 7.5W luminairealong with all other necessary accessories. Equivalent to philips 34034/14/86. IP44. Approved Makes-Philips/Wipro/K-Lite
61UP & Down Light :- Supply, Installation, assembling, connection, testing & commissioning of LED FIXTURE -NWL-17D,20W,LED,3000k, IP 66 Light NWL-17S: wall mount light with up and downillumination, The housing in light weight, made of high strength die cast aluminium and coated by static powder making it weather resistant.Protection screen in tempered glass with high impact resistance . Premium thermal management by high heat conductivity aluminum alloy and thermal fins.Pure Polyester powder coating. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP66 rated. Height – 175mm, Dia.-110mm, Weight - 1Kgs. Power LED Module with high efficacy COB LED, voltage input AC100-277V,50/60Hz. In-Built Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage& Over- Current, with in-built surge protection.Estimated LED Lifetime is 70,000 hours minimum. LM80 report from LED Manufacturer . Light fixture Lumen output is 1668 Lumens. . Sample Should be submitted for concerned engineer incharge for approval of light fixture. Approved Makes-NERI/Iguzzini/Bega/Phillips/Havells/Orient/Bajaj/Crompton/Surya along with all other necessary accessories.
62Roof Light : Supply, Installation, assembling, connection, testing & commissioning of CEILING LED Fixture NCL-02S-LED 12W,LED,3000k Electronic Driver which offers Protection against Short Circuit, Over- Voltage& Over- Current, IP 65 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum. Make - NERI-LED Fixture NCL-02S-LED 12W/Iguzzini/Bega/Hess/DW Windsor/Phillips/Havells/Orient/Bajaj/Crompton/Surya
63LED FIXTURE - Supply, Installation, assembling, connection, testing & commissioning of Circular Ground Buried Light ,NGB-6-3,3W,LED,3000k, IP 67 Light NGB-6-3: The housing in light weight, made of high strength die cast aluminium .Protection screen in tempered glass with high impact resistance. SS Cover. Pure Polyester powder coating. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP67 rated. Height – 98mm, Dia.-85mm, Weight - 0.55Kgs. Power LED Module with high efficacy LED"s, on Printed Circuit Board with metal core plate, Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection. Lens should offer 8°/15°/30° options to cater different lighting needs.Estimated LED Lifetime is L70-50,000 hours minimum. LM80 report from LED Manufacturer should be submitted. Minimum Light fixture Lumen output is 200Lumens. Sample Should be submitted for concerned engineer in charge for approval of light fixture. Approved Makes-NERI/Iguzzini/Bega/Phillips/Havells/Orient/Bajaj/Crompton/Surya
64SITCof exhuast fan (450mm)
65DWC PIPES, Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
66200 mm dia (OD-200 mm & ID-175 mm nominal)
67UPS
68Supply installation Testing and commissioning of 6 KVA (SINGLE PHASE) on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output with minimum 15 minutes battery back up of each UPS. Approved Makes-Eaton, Neumeric, APC
69CABLE TRAY, Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
70150 mm width X 50 mm depth X 1.6 mm thickness
71Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
72150 mm width X 50 mm depth X 1.6 mm thickness
73Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
74150 mm width X 50 mm depth X 1.6 mm thickness
75Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
76150 mm width X 50 mm depth X 1.6 mm thickness
77FIRE DETECTION SYSTEM, Design, Supply, Install, Testing of all Fire Alarm Components and Commissioning of a Complete New Automatic Analog Addressable type Fire Alarm and Detection System complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest NFPA guidelines and the specifications, drawings submitted here with.Note : - Quantity mentioned here under is just for reference;Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall allow for all necessary accessories to comply the installation and design to IEC requirements, which brodally includes all necessary hardware and software.
78Supply, Installation, Testing And Commissioning of One Loop Addressable Fire Alarm Control Panel having capacity of 200 devices of any combination, shall having Netwroking facility with other panel & center graphics software. Approved Makes- Honeywell / Simplex / Siemens
79Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Copper armoured/unarmoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC
80Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
81Supply, Installation, Testing And Commissioning of One Addressable Multi Sensor Detectors Below Ceiling with mounting base and all required accesories. Approved Makes- Honeywell / Simplex / Siemens
82Supply, Installation, Testing And Commissioning of One Addressable Multi Sensor Detectors Above Ceiling with mounting base and all required accesories. Approved Makes- Honeywell / Simplex / Siemens
83Supply, Installation, Testing And Commissioning of Response Indicator for indication of ABOVE false ceiling detector activation. Approved Makes- Honeywell / Simplex / Siemens
84Supply, Installation, Testing And Commissioning of One Addressable Heat Detectors with mounting base and all required accesories. Approved Makes- Honeywell / Simplex / Siemens
85Supply, Installation, Testing And Commissioning of One Addressable Manual Call Pointwith all required accesories. Approved Makes- Honeywell / Simplex / Siemens
86Supply, Installation, Testing And Commissioning of Addressable Hooter with Strobe having 95 db sound and 110 cd. Approved Makes- Honeywell / Simplex / Siemens
87Supply, Installation, Testing And Commissioning of Addressable Isolator Module. Approved Makes- Honeywell / Simplex / Siemens
88Supply, Installation, Testing And Commissioning of Addressable Control Module. Approved Makes- Honeywell / Simplex / Siemens
89Supply, Installation, Testing And Commissioning of Addressable Monitor Module. Approved Makes- Honeywell / Simplex / Siemens
90Any other Item Not included above but required to complete the Job:-[ Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]
91PUBLIC ADDRESS, Design, Supply, Install, Testing of all Public Address Components and Commissioning of a Complete Public Address/EvacuationSystem complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC Standards and the specifications, drawings submitted here with.
92Supply, Installation, Testing and Laying of 2 Core X 1.5 Sq.mm FRLS PVC insulated Shielded Copper armoured/unarmoured cable with all required accessories. Approved Makes- KRYSTAL/Polycab/RRcable/KEC
93Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
946W Ceiling Speaker: Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W Approved Makes- Honeywell / Simplex / Siemens / BOSE
95Power Amplifiers: Supply, Installation, Testing and Commissioning of 240W amplifier, and 4-16 Ohms transformer isolated, Frequency responce 60 Hz~15 kHz ( ± 3 dB ), LED status indicators, Including DC12V fan, Rated Power 480W, Require Power AC 220 V / 50 Hz, DC protection. Approved Makes- Honeywell / Simplex / Siemens / BOSE
96Supply, Installation, Testing and Commissioning of CD Player with in built FM,USB,SD Card Supported. Approved Makes- Honeywell / Simplex / Siemens
97Any other Item Not included above but required to complete the Job:-[ Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]
98CCTV SYSTEM, Design, Supply, Install, Testing,Commissionnig of CCTV System complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with.
99Supply, installation, testing and commissioning of Cat6 A cable. Make:- HUBER+SUHNER/SIEMON/PANDUIT/DURANET
100Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
101Supply, Installation, Testing & Commissiong of 3 MP IR Dome Camera 1/3? Megapixel progressive scan Exmor CMOS, Infrared, Dome camerawith D/N ICR, IR, varifocal lens, 2.8mm-12mm, F1.6, with Audio, H.264, IP66 rated 720p @ 25fps, H.264: 4–8192 kbps, BLC/HLC/DWDR, IR distance up to 30m, RJ-45 connection, Inbuilt microSD card slot, BLC/HLC/DWDR, 3D DNR, ROI, ONVIF, PoE Complete as per specification, IP66, IK10, Including necessary accessories for mounting. Approved Makes- Honeywell / Simplex / Siemens
102Supply, Installation, Testing & Commissioning of 16-channel network video recorder (NVR), Real-time recording: Up to 16 channels 1080P @ 4Mbps, Operating System LINUX, H.265, H.264 high quality decoding, RAID-0/1/5/6/10 support, N+1 redundancy, motion detection, 3 USB 2.0 ports, USB storage device, 2 RJ-45 port, 1 RS-232, Hot swap, 2 bay HDDs,Support ONVIF Profile S, HTTP/HTTPS, TCP/IP, RTSP, UDP, NTP, HTTPS, DHCP, IP Search protocols can support Approved Makes- Honeywell / Simplex / Siemens
103Hard Drive Disk:SITC ofEnterprise surveilliance HDD 8 TB for 30 days storage at D1 resolultion. Approved Makes- Honeywell / Simplex / Siemens
104Supply, Installation, Testing and Commissioning of industrial type 32" LED Display for 24x7 runningg (ON), 1920 X 1080 Resolution, 450 CD/M2 Brightness, Wall Mounting Bracket. Approved Makes- Honeywell / Simplex / Siemens
105Any other Item Not included above but required to complete the Job:-[ Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]
106DATA NETWORKING (PASSIVE PART ONLY), Design, Supply, Install, Testing and Commissioning of all Data NetworkingSystem complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with.Note : - Quantity mentioned here under is just for reference;Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall allow for all necessary accessories to comply the installation and design to IEC requirements, which brodally includes all necessary hardware and software.
107RJ-45 socket outlet point with back box, plate, etc. all require to complete job. Approved Makes- Honeywell / Simplex / Siemens
108CAT-6 (Systemax) cable for computer socket outlets from data switch to computer point laid through raceways/conduits/floor trunks etc with required termination arrangment to complete the Job. (Rates of raceways/conduits/floor trunks shall be excluded) Make:- HUBER+SUHNER/SIEMON/PANDUIT/DURANET
109Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
110Supply, Installation, Testing and Commissioning of 24 Port PoE10/100/1000 Mbps Gigabit network MANAGABLE swicthes with IEEE 802.3x Flow Contro & RoHS compliant along with SFP portfo network switches. Approved Makes- Honeywell / Simplex / Siemens
111Supply, Installation, Testing and Commissioning of 2 mtr. Cat 6 Patch cord. Approved Makes- Honeywell / Simplex / Siemens
112Supply, Installation, Testing and Commissioning of 24 Port fully loaded patch panel Approved Makes- Honeywell / Simplex / Siemens
113Supply, Installation, Testing and Commissioning of Wirelss Access Point shall have IEEE 802.11ac, 802.11n, 802.11g, 802.11b, 802.3af, 802.3u, 802.1X (security authentication), 802.1Q (VLAN),802.1D (Spanning Tree), 802.11i (WPA2 security), 802.11e (wireless QoS), IPv4 (RFC 791), IPv6 (RFC 2460),LAN Gigabit Ethernet auto-sensing,10/100/1000 Ethernet, with support for 802.3af /at PoE, power port for AC adapter (included) Make :- CISCO,NetGear,HP
114Wall mounted network Rack for 12U switch mounting with fixing accessories Approved Makes- Honeywell / Simplex / Siemens
115Any other Item Not included above but required to complete the Job:-[Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]
116TELEPHONE SYSTEM , Design, Supply, Install, Testing and Commissioning of Telephone System complete with all items mentioned but not limited to below: -In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with.
117Supply,laying and termination of 0.5 mm dia tinned copper 2 pair telephone cable.
118Supply, installation, testing and commissioning of following sizes of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
119Supply ,testing and commissioning of RJ-45 socket outlet point. Approved Makes- Honeywell / Simplex / Siemens
120Supply and fixing of 50 pair telephone tag box with KRONE terminal Approved Makes- Honeywell / Simplex / Siemens
121Supply, Installation, Testing and Commissioning of Computer rack moutned type EPABX system having following configuration - 1 no. PIR incoming lines / 4 analog lines / outgoing 50 lines / Caller on hold / Auto dialler. Approved Makes- Honeywell / Simplex / Siemens
122Supply,testing of Caller ID Key Pad Telephones Approved Makes- Honeywell / Simplex / Siemens
123Any other Item Not included above but required to complete the Job:-[ Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]
124FIBER OPTIC & DWC PIPE
125Supply, Installation, assembling, connection, testing & commissioning of Fiber Optic Single Mode 12 core outdoor with all necessary accessories to comply the installation. Approved Makes- FINOLEX AND REPUTED MAKES
126Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
127LIAISON WORK, Liaison with Local Electricity board for Permanent Electrical Power & DG set installation & Getting Approval from Licensee, Electrical Inspector - IM & E Dept.The scope includes to get the required power including DG Sets complete with providing necessary drg/document/arrangingvisit etc from requirement of statutory authority.
128The payment towards official payment shall be reimbursedagainst receipt of such payment.
129O & M FOR 5 YEARS
130Operation and maintanance for 5 year for all parts as per above BOQ