| 1 | Construction of RCC air valve pillar including GI pipes, flanges, bend, MS clamps, rubber sheet, nut bolts/jointing materials etc in M-20 grade cement concrete of 2m height from Natural Ground Level in required shape and size as per approved drawing in all types of soils/rock disposing of surplus excavated materials within a lead of 50 m as per approved drawing complete including all charges at appropriate location in pipeline as per specification mentioned in the scope of work and as per direction of Engineer In Charge. G.I pipes and fittings of dia. |
| 2 | MSITC of Battery Operated Ultrasonic Flow Meter Application: Clear water Electronics Transmitter: Field Mount Weather Proof IP67 Number of Paths: Single Power Supply: Battery Operated MOC Electronics Enclosure: Aluminium Die Cast Electrical Connection: M20 *1.5 F Communication Output: GSM (Per day 1 SMS for 2 Mob.No.) Process Pressure Calibration Range: 10 Kg Spool Piece: With Spool Piece Electronics: Remote with 10 Mtr cable Flow Tube Protection Class: IP 68 Process Connection: Flanged Material of construction - Flange: MS Flange Standard and Rating: ANSI 150 B16.5 Material of construction - Flow Tube: SS 304 Material of construction - Sensor: SS 304 Insertion Flow Sensor Installation: Fixed Inline Pressure Sensor: 10 Kg Accuracy: ± 0.5% of F.S. Low Battery indication: Provided including all materials and making connection with existing pipeline required for Ultrasonic Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. |
| 3 | 150 mm dia |
| 4 | 200 mm dia |
| 5 | 250 mm dia |
| 6 | Construction of Village Transfer Chambers |
| 7 | Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course,RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box withhinged cover 100x100x75mm (deep), including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. |
| 8 | 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve |
| 9 | 90cm x 90cm x 100cm (depth) for 200/250/300 mm dia valve |
| 10 | Extension Spindles for Gate Valves -600 mm for Water Supply System including surface box for service connection valves as per the approval of Engineer In Charge |
| 11 | 50-150 mm |
| 12 | 200-400 mm |
| 13 | Surface Box for Extension Spindle |
| 14 | Glycerine filled pressure gauges (0-10 kg) |
| 15 | Provision for National Highway/State Highway Crossing for Rising Main/ Cluster Distribution/Village Distribution by Trenchless Technology including charges to be deposited to concerned authorities at 14 locations |
| 16 | Provision for replacement of Impeller from 512mm to 549mm is proposed as per charactorstic curves of existing Mather+Plate (Wilo) make pumping set Modal No. SCP-400-550-HA at BUDSU Pump House . (1W+1S)Make:- M/s Mather+Platt |
| 17 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications |
| 18 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. (Total new pumping set to be instaled are (2W+2S) & ((82+206)288*2) KW |
| 19 | Providing, installation, testing and commissioning of MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . |
| 20 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel),other accessariesincluding all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. |
| 21 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.- |
| 22 | 300 mm dia 6mm thk |
| 23 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. - |
| 24 | 300 mm dia 6mm thk |
| 25 | Construction of Flow meter chamber |
| 26 | Provision for removing and installation of new pumpset and impeller in the existing pump set |
| 27 | Pumps for Rising Main |
| 28 | Providing, installation, testing, trial run and commissioning of the following, as per specifications |
| 29 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 30 | GHATWA & MANJI KI DHNAI PRO. OHSR route18 LPS / 75 m head/30 KW (1W+1S) |
| 31 | NALOT & GAGWADA PRO OHSR route8 LPS / 75 m head/12 KW (1W+1S) |
| 32 | KUKANWALIEX. & PRO, HARITPYURA PRO, KANKARIYA & INDALI OHSR route26 LPS / 110 m head/54 KW (1W+1S) |
| 33 | CHITAWA EX. & PRO. OHSR route12 LPS / 50 m head/12 KW (1W+1S) |
| 34 | CHHAPRI PRO, SHIVPURVI EX. & PRO, SABALPURA & CHANDPURA PRO OHSR route19 LPS / 75 m head/26 KW (1W+1S) |
| 35 | RASAL, TORDA PRO & RANASAR PRO OHSR route17 LPS / 55 m head/17 KW (1W+1S) |
| 36 | TRISINGIYA, SARGOT PADAMPURA,LICHANA EX. & PRO. & SHREE NAGAR PRO. OHSR route19 LPS / 75 m head/26 KW (1W+1S) |
| 37 | Provision for replacement of Impeller from 288mm to 356mm is proposed as per charactorstic curves of existing Kirloskar make pumping set modal No. DSM 80/36/2 (1W+1S) at Rooppura (Kuchaman Pump House) |
| 38 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. (Total new pumping set to be installed are (4W+4S) |
| 39 | Providing, installation, testing and commissioning of MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . |
| 40 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel),other accessariesincluding all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. |
| 41 | MS suction pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-6mm thk |
| 42 | 100 mm dia 6mm thk |
| 43 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.- ( for Nalot & Gagawada) |
| 44 | 100 mm dia 6mm thk |
| 45 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. - |
| 46 | 100 mm dia 6mm thk |
| 47 | Construction of Flow meter chamber |
| 48 | Provision for disconnecting the existing pumps and fixing new pumps |
| 49 | Provision for removing and refixing of impeller in the existing pump set |
| 50 | Online Booster |
| 51 | Providing, installation, testing, trial run and commissioning of the following, as per specifications |
| 52 | Centrifugal HSC Pumps & motor all other accessories of following duty conditions in Following locations |
| 53 | ASPURA / 24 m head/3 KW (1W+1S) |
| 54 | PANWARI / 10 m head/1 KW (1W+1S) |
| 55 | HARIPURA / 10 m head/3 KW (1W+1S) |
| 56 | NAGWARA / 16 m head/4.5 KW (1W+1S) |
| 57 | DOLATPURA / 10 m head/0.5 KW (1W+1S) |
| 58 | CHARNAWAS / 18 m head/1 KW (1W+1S) |
| 59 | KHORANDI / 15 m head/2 KW (1W+1S) |
| 60 | PREMPURA / 11 m head/1 KW (1W+1S) |
| 61 | JASAWANT PURA / 4 m head/0.25 KW (1W+1S) |
| 62 | G.I. discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.- |
| 63 | 50 mm dia |
| 64 | 80 mm dia |
| 65 | G.I. common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. - |
| 66 | 50 mm dia |
| 67 | 80 mm dia |
| 68 | Providing, lowering, aligning, fixing in position Brass full way valve with C.I. wheel (screwed end) |
| 69 | 50 mm dia |
| 70 | 80 mm dia |
| 71 | Providing, lowering, aligning, fixing in position Gunmetal non-return valve-horizontal (screwed end) |
| 72 | 50 mm dia |
| 73 | 80 mm dia |
| 74 | Add miscellaneous item for GI pipe fittings |
| 75 | Provision for interconnection and fixing new pumps |
| 76 | Provision for PLC-SCADA System @1.5% of project cost |
| 77 | Provision for O&M for Ten years |