Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works At Zone A To G At Mil Stn Agartala Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works , AGARTALA-Tripura

Military Engineer Services-MES has published Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works At Zone A To G At Mil Stn Agartala Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works . Submission Date for this Tender is 28-08-2021. Electric Pole Tenders in AGARTALA Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

28784824
Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works At Zone A To G At Mil Stn Agartala Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works
Open Tender
Indian
Tripura
AGARTALA
28-08-2021

Tender Details

Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works At Zone A To G At Mil Stn Agartala Repair / Replacement And Maint Of Lt Distribution Lines Panels Damage Pole, Service Cables And Allied Works At Zone A To G At Mil Stn Agartala

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 8.99 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/REPLACEMENT AND MAINT OF LT DISTRIBUTION LINES, PANELS, DAMAGE POLE, SERVICE CABLES AND ALLIED WORKS AT ZONE "A" TO "G" AT MIL STN AGARTALA
Sl. No. Item Description
1Schedule"A" Part-I: E&M works
2Material & Labour for aluminium conductor steel reinforced (ACSR) of any size mounting on over head line, stringing properly on insulator with required span and sag including binding with aluminium conductor of 2 mm dia as binding wire providing jumpers with the same size of ACSR conductor (where required) all as specified and directed.
3Supply and fixing pin type insulator 100 mm height, 65 mm dia 1100 volts grade made of porcelain vitreous (white/brown) with one galvanised mild steel spindle two galvanised iron washer and one GI nut over LT pole all as specified and directed.
4Supply and fixing shackle type insulators 75 mm height, 90 mm dia, 1100 volt grade made of porcelain vitreous (White) with one galvanised mild steel trips of 31 mm width 3.00 mm thick, not less 15 cm long, fixing 12 mm dia nuts & bolts over the LT pole all as specified and directed.
5Material & Labour for cross arm, bracing, supports, clamps and back plates fabricated from structural steel section, flat strips, etc including nuts and bolts with washers, welding bending cold or hot drilling holes for bolts of any size as indicated / directed and inclusive ofpreparation of surfaces for one finishing coat of synthetic enamelled paint over a coat of primer complete all as specified and directed .
6Material & Labour for cradle guard, hexagonal/rectangular or as per existing shape fabricated with galvanised steel wire 3.15 mm dia including binding the guards with cradle supporting GI wire complete all as specified and directed.
7Supply and fixing steel tubular swaged pole as per IS 2713 (Part 1 to 3) - 1980, type 410 SP-31 (09 mtr long ) complete with cast iron base plate final taper plug, pole cap, bolts/nuts, screws/washes, painting with two coats of black bituminous paint through out internally and externally upto planting depth and two coasts of black and white alternate strips 30 cm each upto 1.2 mtr from the ground level. The remaining external position shall be painted with two coat of aluminium paint including numbering to pole complete all as specified and directed.(Note:- Earth work, PCC work, shall be measured and paid separately.)
8Material & Labour for stay assembly using 16 mm dia stay rod complete with accessories as shown in electrical plate No 1 including properly tying with LT pole and stay clamp all as specified and directed.
9Material & Labour for loop type insulator, made of porcelain vitreous (White) small size with over all dimension 65 x 90 mm, clearance of hole 16 mm including properly tying within the stay strand all as specified and directed.
10Material & Labour for galvanised stay strand of size 7/3.15 including properly tying with LTpole clamp and stay clamp all as specified and directed.
11Supply and fixing of PVC line separator suitable for two conductor line LT, 1100 volt grade as per sample including all fixing arrangement in between the span of over head line all as specified and directed.
12Supply and fixing of PVC line separator suitable for four line OH conductor LT, 1100 volt grade as per sample including all fixing arrangement in between the span of over head line all as specified and directed.
13Material & Labour for opening of ACSR conductor / Jumper after opening of binding wire from insulator fixed over LT poles and restretching/ restringing/retightening of ACSR conductor of any size, rebinding the conductor over insulator by using aluminium conductor of 2 mm dia as binding wire, making Jumper in the similar way complete all as specified and directed.
14Material & Labour heavy duty armoured LT under ground cable of size 240 Sqmm, 3.5 core 1100 V grade PVC insulated ,PVC sheathed ,multi stranded aluminiumcable of following size inpipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc including lugs for both ends and making good the disturbed surfaces complete all as specified and directed.
15All as per item No.13 above but but of size 120 Sqmm 3.5 core
16All as per item No.13 above but but of size 95 Sqmm 3.5 core
17All as per item No.13 above but but of size 50 Sqmm 3.5 core
18All as per item No.13 above but but of size 35 Sqmm 3.5 core
19All as per item No.13 above but but of size 10 Sqmm 4 core
20Supplying and fixing 1100 volts grade heavy duty cables PVC insulated aluminium conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
21Supply and fixing MCCB 630 Amp, 36 KA breaking capacity, 4 Pole, fixed thermal and magnetic setting type, fixed on existing panel complete all as specified and as directed.
22Supply and fixing MCCB 400 Amp, 36 KA breaking capacity, 4 Pole, fixed thermal and magnetic setting type, fixed on existing panel complete all as specified and as directed.
23Supply and fixing MCCB 250 Amp, 25 KA breaking capacity, 4 Pole, fixed thermal and magnetic setting type, fixed on existing panel complete all as specified and as directed.
24Supply and fixing MCCB 200 Amp, 25 KA breaking capacity, 4 Pole, adjustable thermal and fixed magnetic setting type, fixed on existing panel complete all as specified and as directed.
25Supply and fixing MCCB 150 Amp, 25 KA breaking capacity, 4 Pole, adjustable thermal and fixed magnetic setting type, fixed on existing panel complete all as specified and as directed.
26Supply and fixing MCCB 100 Amp, 25 KA breaking capacity, 4 Pole, adjustable thermal and fixed magnetic setting type, fixed on existing panel complete all as specified and as directed.
27Material & Labour in replacement of tubes of size 80 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ as reqd ] of proper sizes completefor protection cables complete all as specified and directed. Make-ISI Marked / Nezone
28All as per item No. 25 of size 50mm bore.
29All as per item No. 25 but of size 40mm bore
30Boring under roads with mechanical arrangement with 50 mm dia GI tubing without disturbing the top surface of the road for passing the cable across the road complete all as specified and directed.
31Material & Labour for earthing complete with galvanized steel earth plate electrode (600x600x6.3)mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) connected to galvanized iron strip 25 x 4 mm as earthing lead by means of nut, bolts and washers, steel pipe of 25mm bore light grade for protection of earth lead with PCC chamber (1:2:4) type B1 using 20mm graded stone aggregate internal surface of concrete chamber shall be given 10mm thick plaster in CM (1:4), funnel with wire mesh, 50mm thick cover RCC (1:2:4) type B1 using 20 graded aggregate reinforcement with 8mm dia MS bar at 80mm centre to centre both way and incl charcoal dust and common salt all as shown in electrical Plate No.3 of SSR Part-I as specified incl necessary excavation and earth work and connecting the earth to earth test point including testing complete.
32Material & Labour for preparation of external surface of LT steel tubular pole 9.0 mtr long by scrubbing with emery paper, carry out one coat of synthetic enamel paint in black and white alternate strips each 30 cm upto 1.2 mtr from the ground level and one coat of aluminium paint over the remaining portion including all cross arms, bracings, clamps, etc and marking the pole Nos complete all as specified and directed.
33Labour only for cleaning the route of LT overhead line by cutting tree branches/ bushes, removing unwanted growth around the conductor/ pole stay wire Jumper with in the areaof 1 mtr both side of LT over head line, bottom of poles, stay assy all as directed.
34M & L for replacement of rusted/corroded security light bracket made out of GI pipe of light grade1.2 RMx40mm dia and 0.3RM x32 mm dia at one end for inserting of light fitting, properly shaped, bended, & fixed on the pole through MS flat by nut, bolt & washer of suitable sizes incl dismantling the old unsv existing one complete all as specified and directed.
35Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coats of (approved colours) synthetic enamel paint 1st grade quality complete all as specified and directed.
36Material & LabourAnti climbing devicescomprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately)
37M & LAnti climbing devicescomprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately)
38Material & Labour Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size
39Excavation in trench n. exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out of soft/loose soil/brick all as specified
40All as per item No.36but exceeding 1.5 mtr depth and n.exc 3.0 mtr depth
41Removing of excavated surplus soil to a distance not exceeding 50 mtr and depositing/ spreading where directed at level of n.exc 1.5 mtr above the starting point.
42Returning filling in spreading, levelling and well ramming in layers n.exc 25 cm thick above the ground level complete all as specified.
43Material & Labour for sand cushioning for cable protection with dry river sand and punning to provide required cushioning for UG cable all as specified and directed.
44Supply and fixing bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
45Material and labour for PCC 1:4:8 type D-2 with 40 mm graded aggregate for foundation of pole, stay , panels etc all as specified and directed
46Material & Labour for plain cement concrete (1:2:4) B1 type using 20 mm graded coarse stone aggregate for foundation/coping of poles complete all as specified and directed.
47Taking up old unsv LT UG cable of any size from trenches/road /floor/poles & wall complete all as specified and directed.
48Dismantling of existing unserviceable ACSR conductor of any size from pole and removing from site complete all as directed.
49Dismantling of broken, cracked, unserviceable LT pin/shackle insulator of any make and anysize complete all as directed at site.
50Dismantling of old rusted Cross Arms bracing support, clamps and back plate of any sections from poles setting aside complete all as directed at site.
51Dismantling/removing of unserviceable earth continuity conductor/cradle guard supporting wire/stay strand/anticlimbing device of any size and setting aside all as directed at site.
52Dismantling/removing of old damaged rusted steel tubular/PCC Poles of any description and taking asides including breaking of existing PCC foundation and making good to disturbed surface complete all as specified and directed .
53Dismantling of old damaged stay assembly including demolition of PCC making good to disturbed surfaces complete all as specified
54Supply and fixing outdoor type cable entry junction box of size 250 x 200 x 100 mm, weather proof with knockouts for cable entry- black colour including 4 Nos terminal for cable jointingwith necessary fixing arrangement, fixed on pole/ walls complete all as specified and as directed. Make - Sintex, Model - GSJB-2520 or equivalent Model of Hansel
55Supply and fixing outdoor type cable entry junction box of size 300 x 200 x 105 mm, weather proof with knockouts for cable entry- black colour including 4 Nos terminal for cable jointing with necessary fixing arrangement, fixed on pole/ walls complete all as specified and as directed. Make - Sintex, Model - GSJB-3020 or equivalent Model of Hansel
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail