Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-09-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-09-2021 |
| 2 | 29-08-2021 | REVISED BOQ | BOQ | 04-09-2021 |
| 3 | 28-08-2021 | AMDT03 | Other | 04-09-2021 |
| 4 | 24-08-2021 | Amendment No 2 | Date | 04-09-2021 |
| 5 | 18-08-2021 | AMDT DATE | Date | 30-08-2021 |
| Sl. No. | Item Description |
| 1 | REPAIRS/MAINT TO INTERNAL ELECTRIFICATIONS |
| 2 | M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc, Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed. |
| 3 | M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. by using Cement Mortar 1:3 including providing Surface Treatment to match the Existing Treatment/ Finishes on Ground, complete all as specified and as directed. |
| 4 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed. |
| 5 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed. |
| 6 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed. |
| 7 | M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and all as directed. |
| 8 | M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 16 AMP POINT on INDEPENDENT BOARD, complete all as specified and all as directed. |
| 9 | M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.NOTE :-(a)Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also be Mesured as ONE UNIT.(b)Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 10 | S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed. |
| 11 | S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed. |
| 12 | S&F PVC Conduit Pipe (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Conduit Pipe, complete all as specified and as directed. |
| 13 | S&F Rigid Non-metallic PVC Conduit of size 25mm (External Dia) exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc. including Taking down/ out unserviceable PVC Conduit Pipe, complete all as specified and as directed. |
| 14 | S&F Rigid Non-metallic PVC Conduit of size 40mm (External Dia) exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc. including Taking down/ out unserviceable PVC Conduit Pipe, complete all as specified and as directed. |
| 15 | S&F PVC Rectangular Block of size 100x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed. |
| 16 | S&F PVC Rectangular Block of size 350x300x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed. |
| 17 | S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 18 | S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed. |
| 19 | S&F Switch Piano Flush type, 16 Amp, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed. |
| 20 | S&F Switch Modular type, 6 Amp, 1-Module,Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch, complete all as specified and as directed. |
| 21 | S&F Switch Modular type, 16 Amp, 1-Module, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch, complete all as specified and as directed. |
| 22 | S&F Bell Push Modular type, 6 Amp, 1-Module, Single Pole, Flush type, 230 Volt AC for operating Bell/ Buzzer and connecting up including Taking down/ out unserviceable Bell Push, complete all as specified and as directed. |
| 23 | S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 24 | S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Socket Outlet, complete all as specified and as directed. |
| 25 | S&F Socket Outlet Modular type, 6 Amp, 2-Modules, 2/3 Pin, Single Pole, Multi-purpose, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch, complete all as specified and as directed. |
| 26 | S&F Socket Outlet Modular type, 6/16 Amp, 2-Modules, 2/3 Pin, Single Pole, Multi-purpose, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch, complete all as specified and as directed. |
| 27 | S&F Socket Outlet 16 Amp, 3 Pin,2-in-1, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Socket Outlet, complete all as specified and as directed. |
| 28 | S&F Plug Top 6 Amp, 3 Pin, ISI marked, 230 Volt AC and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 29 | S&F Plug Top 16 Amp, 3 Pin, ISI marked, 230 Volt AC and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 30 | S&F Switch Socket Combination 6/16 Amp, 3 Pin, 2-in-1, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 31 | S&F Switch Socket Combination 6/16 Amp, 3 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed. |
| 32 | S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed. |
| 33 | S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up including Taking down/ out unserviceable Ceiling Rose, complete all as specified and as directed. |
| 34 | S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt and connecting up, complete all as specified and as directed. |
| 35 | S&F Ceiling Fan Regulator, Dimmar Switch type, 230 Volt AC, Rotary Stepped, Electronic type 120/280 Volt and connecting up including Taking down/ out unserviceable Fan Regulator, complete all as specified and as directed. |
| 36 | S&F Ceiling Fan Regulator, Modular type, 2 Modules, Stepped type, 120 Watt suitable for Ceiling Fan 48\"/56\" and connecting up including Taking down/ out unserviceable Fan Regulator, complete all as specified and as directed. |
| 37 | S&F Bell Ding Dong, 230 Volt AC, Single Pole and connecting up including Taking down/out unserviceable Bell, complete all as specified and as directed. |
| 38 | S&F Angle Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up including Taking down/out unserviceable Holder, complete all as specified and as directed. |
| 39 | S&F Ballast Electronic type (as approved) and fixing to CFL/FTL 9/10/11/13 Watt Fitting and connecting up including Taking down/o ut unserviceable Ballast, complete all as specified and as directed. |
| 40 | S&F Ballast Electronic type (as approved) and fixing to CFL/FTL 18/20 Watt Fitting and connecting up including Taking down/o ut unserviceable Ballast, complete all as specified and as directed. |
| 41 | S&F Ballast Electronic type (as approved) and fixing to existing FTL 36/40 Watt Fitting and connecting up including Taking down/o ut unserviceable Ballast, complete all as specified and as directed. |
| 42 | S&F CFL 18 Watt (as approved), 2 Pin, 230 Volt, 50 Hz and fixing to existing Light Fitting including Taking down/out unserviceable CFL, complete all as specified and as directed. |
| 43 | S&F CFL 36 Watt (as approved), 4 Pin, 230 Volt, 50 Hz and fixing to existing Light Fitting including Taking down/out unserviceable CFL, complete all as specified and as directed. |
| 44 | S&F LED Lamp 5 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out unserviceable Lamp, complete all as specified and as directed. |
| 45 | S&F LED Lamp 7 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out unserviceable Lamp, complete all as specified and as directed. |
| 46 | S&F LED Lamp 10 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out unserviceable Lamp, complete all as specified and as directed. |
| 47 | S&F LED Lamp 15 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out unserviceable Lamp, complete all as specified and as directed. |
| 48 | S&F LED Light Fitting 1x12 Watt, Slim Surface Mounted, Round LED Panel Aluminum Die Cast Body with Premium Diffuser to ensure Glare Free and Even Distribution of Light, 230 Volt, Indoor Recess mounting Down Light Circular type with Reflector and Detachable Tray with LED Lamp, Electronic Driver, Connector Blocks, etc., complete with all Accessories, Pre-wired, connecting up with and including suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/out unserviceable Light Fitting, complete all as specified and as directed.MAKE : HAVELLS, Cat No. LHEAAVP5IL1W012 or equivalent Model in Make : BAJAJ/ CG/ C&S/ HPL/ PHILIPS |
| 49 | S&F LED Downlighter (White) 18 Watt, Round shape, Lumans 1250, Bright Diffuser Light operating Voltage 160-360 Volts, Diameter 190mm and quality approved LED Light Source ensure durable Performance, Good Colour Renrening Index Performance, complete with all Accessories, Pre-wired, connecting up with and including suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/out unserviceable Light Fitting, complete all as specified and as directed.MAKE : PHILIPS, Cat No. 919215850705 18 Watt LED Downlighter (White) or equivalent in Model in Make : BAJAJ/ CG/ C&S/ HAVELLS/ HPL |
| 50 | S&F LED Tube Light Fitting 1x20 Watt with 20 Watt LED Strip and Driver having Aluminium Extrution Housing, complete with all Accessories, Pre-wired and connecting up with suitable size 3 Core Twisted Flexible Copper Conductor Cable including Taking down/out unserviceable Light Fitting, complete all as specified and as directed.MAKE : C&S, Cat No. LTTB4F20WLED/W or equivalent Model in Make : BAJAJ/ CG/ HAVELLS/ PHILIPS/ HPL |
| 51 | S&F LED Tube Light Fitting 1x20 Watt, High quality Indoor, with Single Side Connection have large diameter for increase Convection Heat Transfer of capacity 20 Watt, Lumens 2000/1800, complete with all Accessories, Pre-wired and connecting up with suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out unserviceable Light Fitting, complete all as specified and as directed.MAKE : C&S, Cat No. LT4F20WLEDT8/WDI or equivalent Model in Make : BAJAJ/ CG/ HAVELLS/ PHILIPS/ HPL |
| 52 | S&F LED PLUTO NEO PANEL Light Fitting 30 Watt, 2\"x2\" Fitting Enviromentaly Friendly, New Generation, Ultra Modern Recess mounting/ Grid Celing mounted with Electronic Driver 30 Watt with High Brightness SMD LEDs as Light Source, complete with all Accessories, Pre-wired and connecting up with suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out unserviceable Light Fitting, complete all as specified and as directed. |
| 53 | S&F MCB 6 to 32 Amp, Single Pole, \"C\" Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 54 | S&F MCB 6 Amp to 32 Amp, Single Pole & Neutral, \"C\" Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 55 | S&F MCB 40 Amp, Single Pole & Neutral, \"C\" Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 56 | S&F MCB 63 Amp, Triple Pole & Neutral, \"C\" Series, 50 Hz, 10 kA, 415 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 57 | S&F MCB Distribution Board, SPN 2-way, 240 Volt AC, Single Door type of Steel Sheet Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. |
| 58 | S&F MCB Distribution Board, SPN 4-way, 240 Volt AC, Single Door type of Steel Sheet Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. |
| 59 | S&F MCB Distribution Board, SPN 6-way, 240 Volt AC, Single Door type of Steel Sheet Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. |
| 60 | S&F MCB Distribution Board, SPN 8-way, 240 Volt AC, Single Door type of Steel Sheet Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. |
| 61 | S&F MCB Distribution Board, TPN 8-way, 415 Volt, Vertical, Single Door type of Steel Sheet Phoshotised Powder painted with minimum capacity of 200 Amp Neutral Bars, Earth Bar, Dummy Plate and PVC Board of suitable sizeand connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. |
| 62 | S&F PVC insulated Copper Conductor Flexible Cable of size 40/39, 1100 Volt grade and connecting up including Taking down/out unserviceable Flexible Cable, complete all as specified and as directed. |
| 63 | Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade, Heavy duty Cable with PVC insulated Stranded Aluminium Conductor Served with an inner Sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and overall PVC Sheathed, Nominal Cross Section 6.0 Sqmm, 2 Core in Service Connections including Taking down unserviceable Cable, complete all as specified and as directed. |
| 64 | Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade, Heavy duty Cable with PVC insulated Stranded Aluminium Conductor Served with an inner Sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and overall PVC Sheathed, Nominal Cross Section 10 Sqmm, 2 Core in Service Connections including Taking down unserviceable Cable, complete all as specified and as directed. |
| 65 | REPAIRS/MAINT TO FANS |
| 66 | M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at ALONG for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed.NOTE :-(a)Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department.(b)Rewinding & Other Parts required to be replaced will be Measured and Paid separately as \"S&F\"/\"M&L\" under relevant Items. |
| 67 | S&F Ball Bearing (size as per existing one/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed.MAKE : FAG/ NBC/ SKF |
| 68 | S&F Condenser 2.0/2.5 mfd suitable for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.MAKE : AMCAP/ EPCOS/ HAVELLS |
| 69 | S&F Condenser 3.15/4.0 mfd suitable for Exhaust Fan/ Air Circulator Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.MAKE : AMCAP/ EPCOS/ HAVELLS. |
| 70 | S&F Fan Blade Aluminium suitable for Ceiling Fan 1200mm Sweep of any Make/Model, Aero dynamically balanced and screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed. |
| 71 | S&F Fan Blade Aluminium suitable for Ceiling Fan 1400mm Sweep of any Make/Model, Aero dynamically balanced and screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed. |
| 72 | M&L Frame suitable for Exhaust Fan 380/400mm Sweep with Mild Steel Flat and fixing with Bolts, Nuts, Washers, etc. as required/ordered including Taking down/out unserviceable Frame, complete all as specified and as directed. |
| 73 | M&L Grill, Spoke type (sizes as per existing/ as approved) and fixing with Mild Steel Bolts, Nuts, etc. including Taking down/out unserviceable Grill, complete all as specified and as directed. |
| 74 | S&F Gun Metal Bush (size as per existing One/ as approved) suitable for Ceiling/ Exhaust/Cabin Fan of any Make/Model and any Size including Taking down/out unserviceable Bush, complete all as specified and as directed.MAKE : FAG/ NBC/ SKF |
| 75 | M&L Louver Shutter suitable for Exhaust Fan 380mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed. |
| 76 | M&L Louver Shutter suitable for Exhaust Fan 400mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed. |
| 77 | M&L Mild Steel Down Rod 15mm nominal dia and 18\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 78 | M&L Mild Steel Down Rod 15mm nominal dia and 24\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 79 | M&L Mild Steel Down Rod 15mm nominal dia and 36\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 80 | M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 81 | M&L Transporting Ceiling Fan 1400mm Sweep from AGE E/M Store Yard at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 82 | M&L Transporting Exhaust Fan 300/380mm Sweep from AGE E/M Store Yard at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 83 | M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 84 | M&L Transporting Pedestal Fan of any Sweep from AGE E/M Store Yard at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 85 | M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnecting, Preparing old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed. |
| 86 | S&F Ceiling Rose, PVC/Polycarbonate, Isolated Body, 3 Terminals, 230 Volt AC, 6 Amp and connecting up including Taking down/out unserviceable Ceiling Rose, complete all as specified and as directed. |
| 87 | S&F Ceiling Fan Regulator, Dimmar Switch type, 230 Volt AC, Rotary Stepped Electronic type, 120/280 Volt and connecting up including Taking down/ out unserviceable Ceiling Fan Regulator, complete all as specified and as directed. |
| 88 | S&F Modular Fan Regulator, 2 Modules, Step type, 120 Watt suitable for Ceiling Fan 48\"/56\" Sweep and connecting up including Taking down/out unserviceable Fan Regulator, complete all as specified and as directed. |
| 89 | REPAIRS/MAINT TO GEYSERS |
| 90 | M&L Taking/Lowering down unserviceable Electric Water Heater (Geyser) 25 Litre capacity, Storage type from any Situation after disconnecting all Water Supply & Electric Connections and carry out following Checks :-(a)Inspection of Geyser and Opening, Dismantling, Brushing and Cleaning of Storage Water Tank, Removing all Sludge, Scalling and Bleaching from the Tank and Examining of any leakage of Water, Tightening of Nuts, Bolts and Re-installation the same in Original Position complete.(b) Check and Connecting Earth Continuity to Electric Water Heater.(c) Checking and Adjusting of Pressure Release Valve.(d) Check and Maint of Thermostate Valve.(e) Visual Examination of Fusible Plug. |
| 91 | M&L Taking down Electric Water Heater 25 Litre capcity of any Make/ Model by carefuly Un-bolting, Dismantling the Electric Water Heater, Taking out the Aparatus Assembly, Inner Tank, Glass wool, Thermostats, Checking the Point of any leakages on Inner Tank, Brazing for Removing of Leakage, Re-assembling the Electric Water Heater and Re-fixing of Appratus Assembly including Replacing of Glass wool, Re-installation Electric Water Heater in Original Position, Providing all Electrical & Water Supply Connections and Testing, complete all as specified and as directed. |
| 92 | S&F Base Assembly Gasket of any shape and size, suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly Gasket, complete all as specified and as directed. |
| 93 | S&F Base Assembly (Inner), Brass Chromium plated complete of any shape and size with Inlet, Outlet, Thermostate Slot, drain plug, Clamp or Bolts to fixing Heating Element as existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly (Inner), complete all as specified and as directed. |
| 94 | S&F Brass Chromium plated Connection with Brass Chromium plated Adaptor 350mm long, making connection to in Inlet & Outlet suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/ out unserviceable Connection with Adaptor, complete all as specified and as directed. |
| 95 | S&F Fusible Plug in existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model and Testing including Taking down/out unserviceable Fusible Plug, complete all as specified and as directed. |
| 96 | S&F Glass Wool (Insulation Materials) superior quality (as approved) suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking out unserviceable Glass Wool, complete all as specified and as directed. |
| 97 | S&F Heating Element 1.5 KW 230 Volt AC suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA |
| 98 | S&F Heating Element 2.0 KW 230 Volt AC suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA |
| 99 | S&F Indication Lamp Assembly consisting Red & Green in Colour of any shape and size, 230 Volt suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed. |
| 100 | S&F Inner Shell (Inner Tank), ISI marked, made out of Copper Sheet 22 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed. |
| 101 | S&F Inner Shell (Inner Tank), ISI marked, made out of Stainless Steel Sheet 20 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/ Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed. |
| 102 | S&F Outer Body complete with Top & Bottom Cover, Inspection Plate suitable for Electric Water Heater 25 Litre capacity of any Make/Model and applying Two Coats of Synthetic Enamelled Paint (as approved) ove a coat of Red Oxide Zinc Chrome Primer with Spray Painting Machine including Taking down/out unserviceable Outer Body, complete all as specified and as directed. |
| 103 | S&F PVC Connection in Inlet, 15mm bore (dia) and 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed. |
| 104 | S&F Safety Valve, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make/ Model including Taking down/out unserviceable Safety Valve, complete all as specified and as directed. |
| 105 | S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 240 Volt AC suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/out unserviceable Thermostate Switch, complete all as specified and as directed. |
| 106 | M&L Taking down Electric Water Heater 25 Litre capcity of any Make/ Model from the Existing Location after disconnecting all Connections, Cleaning entire Body with Wire Brush for removal of old Paints and making the surfaces Smooth Finishing for Repainting, applying Two Coats of Synthetic Enamel Paint (as per existing Colour Code) over a coat of Red Oxide Zinc Chrome Primer including Removal of unwanted Paints from Glass & Rubber Items, Re-installation the Electric Water Heater in Original Position, complete all as specified and as directed. |
| 107 | S&F PVC insulated, Flexible, Copper multi-stranded Cable, Cross-sectional area 4.0 Sqmm, 3 Core and making Electric connection to Electric Water Heater and Plug Top including Taking down/out unserviceable Cable of any description, complete all as specified and as directed. |
| 108 | S&F Metal Clad Top 2 Pole & Earth 20 Amp, ISI marked and connecting up including Taking down/out unserviceable Metal Clad Top, complete all as specified and as directed. |
| 109 | S&F Plug Top 6 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 110 | S&F Plug Top 16 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 111 | S&F Sheet Metal Enclosure, Single Pole & Neutral, 2 Pin & Earth Plug Top and Socket 20 Amp rating with and including 1 No. MCB 20-32 Amp, Single Pole and connecting up including Taking down/out unserviceable Sheet Metal Enclosure, complete all as specified and as directed. |
| 112 | REPAIRS/MAINT TO SPLIT TYPE AC 1.5 TON/ 2.0 TON CAPACITY |
| 113 | M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for SplitAC 1.5 Ton Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH |
| 114 | M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for SplitAC 2.0 Ton Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH |
| 115 | M&L Condensor Fan Blade Assembly, Heavy duty for Fan Motor (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed.MAKE : CARRIER/ FEDDERS LLOYED/ VOLTAS |
| 116 | M&L Copper Pipe1/2\" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection & Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed. |
| 117 | M&L Copper Pipe5/8\" and 3/8\" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection& Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed. |
| 118 | M&L Flare Nut made out of Brass for Copper pipe 1/2\"/ 3/8\" (as per Existing One/ as approved) including Taking down/ out unserviceable Nut, complete all as specified and as directed. |
| 119 | M&L Insulation On & Around Suction and Discharge Copper Piping with 6.0mm thick Flexible Thermocool Heat Resistant duly scrapped with Sticking Tape & Testing including Taking down/ out unserviceable Insulation, complete all as specified and as directed. |
| 120 | M&L Indoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed.MAKE : AUE/ USHA or equivalent as approved by GE |
| 121 | M&L Outdoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed.MAKE : AUE/ USHA or equivalent as approved by GE |
| 122 | M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed. |
| 123 | M&L Power Circuit PVC Plate (as per Existing One/ as approved) suitable for Split type AC 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit Plate, complete all as specified and as directed. |
| 124 | M&L Sensor Set Dry Cool (as per Existing One/ as approved) suitable for Split type AC 1.5 Ton/ 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Sensor Set, complete all as specified and as directed. |
| 125 | M&L Repairs to Power Circuit (PC) Plate of Split type AC 1.5 Ton, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed. |
| 126 | M&L Repairs to Power Circuit (PC) Plate of Split type AC 2.0 Ton, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed. |
| 127 | M&L Shifting Split type AC 1.5 Ton/ 2.0 Ton Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermocool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed. |
| 128 | Supply & Charging Gas F-22 to Split type Air Conditioner 2.0 Ton Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure & Testing, complete all as specified and as directed. |
| 129 | M&L Dismantling Voltage Stablizer of capacity 3.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed. |
| 130 | M&L Dismantling Voltage Stablizer of capacity 5.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed. |
| 131 | M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.NOTE :-(a)Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping will deem to be included in the Quoted Unit Rate and the same also be Mesured as ONE UNIT.(b)Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 132 | REPAIRS/MAINT TO REFRIGERATORS |
| 133 | M&L Opening Refrigerator/ Freeze 255 Litre Capacity, Re-assembling/ Re-fixing the Same after Flushing Out and Removal of Blockage, necessary Brazing, Replacement of Liquid Line Filter and Recharging the Refrigerator with Freon-12 Refrigerant to obtain the desired Cooling (Temperature) & Testing, complete all as specified and as directed. |
| 134 | M&L Opening Refrigerator/ Freeze 286/ 310 Litre Capacity, Re-assembling/ Re-fixing the Same after Flushing Out and Removal of Blockage, necessary Brazing, Replacement of Liquid Line Filter and Recharging the Refrigerator with Freon-12 Refrigerant to obtain the desired Cooling (Temperature) & Testing, complete all as specified and as directed. |
| 135 | M&L Chilled Freezer Tray Plastic Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 136 | M&L Chilled Freezer Tray Plastic Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 137 | M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 138 | M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 139 | M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed. |
| 140 | M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed. |
| 141 | M&L Hermetically Sealed Compressor (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL |
| 142 | M&L Hermetically Sealed Compressor (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL |
| 143 | M&L Over Load Protector 1/8 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed.MAKE : HITECH/ RENUTRAL/ USHA |
| 144 | M&L Over Load Protector 1/6 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed.MAKE : HITECH/ RENUTRAL/ USHA |
| 145 | M&L Pigmy Lamp 15 Watt, 230 Volt AC (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Lamp, complete all as specified and as directed.MAKE : CROMPTON/ PHILIPS |
| 146 | M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Power Circuit (PC) Plate, complete all as specified and as directed. |
| 147 | M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Power Circuit (PC) Plate, complete all as specified and as directed. |
| 148 | M&L PVC/ Plastic Ice Tray, Superior quality of Large size with PVC Separator Complete (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections including Taking down/ out unserviceable Ice Tray, complete all as specified and as directed. |
| 149 | M&L PVC/ Plastic Vegetable Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 255 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 150 | M&L PVC/ Plastic Vegetable Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed.MAKE : KELVINATORS/ LG/ SAMSUNG |
| 151 | M&L Relay Open type, 1/8 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed.MAKE : HITECH/ RENUTRAL/ USHA |
| 152 | M&L Relay Open type, 1/6 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed.MAKE : HITECH/ RENUTRAL/ USHA |
| 153 | REPAIRS/ MAINT/ SERVICING TO COOLING APPLIENCES |
| 154 | M&L Capacitor 10 mfd Capacity suitable for Water Cooler 40/80 Litre or 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed.MAKE : ASAIN/ KEL/ SPEED/ UNISTAR |
| 155 | M&L Fan Blade Assembly Complete, Heavy duty (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Blade Assembly, complete all as specified and as directed.MAKE : SIDHWAL/ USHA/ VOLTAS |
| 156 | M&L Fan Motor 1/35 HP or 1/32 HP Capacity (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed.MAKE : AUE/ CROMPTON |
| 157 | M&L Hermetically Sealed Compressor Unit (as per Existing One/ as approved), Single Phase suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH |
| 158 | M&L Hermetically Sealed Compressor Unit (as per Existing One/ as approved), Single Phase suitable for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed.MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH |
| 159 | M&L Over Load Protector 2613 (as per Existing One/ as approved) suitable for Water Cooler of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed.MAKE : HITACHI/ TECHEMSHAH |
| 160 | M&L Starting Capacitor 40/60 mfd suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed.MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR |
| 161 | M&L Starting Capacitor 80/100 mfd suitable for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed.MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR |
| 162 | M&L Starting Kit comprising of Relay & Over Load Protector (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Kit, complete all as specified and as directed.MAKE : RENUTRAL/ SHRIRAM |
| 163 | M&L Thermostatic Switch (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Thermostatic Switch, complete all as specified and as directed.MAKE : GODREJ/ INDOFOSS/ RENUTRAL |
| 164 | M&L Denting, Welding to Water Cooler 40/80 Litre Capacity including applying Two Coats of Synthetic Enameled Paint (1st quality/ grade) over a Coat of red Oxide Zinc Chrome Primer with Spray Painting Machine after necessary Preparation of Surfaces including Sencil Writing MES No. with Paint, complete all as specified and as directed. |
| 165 | Supply & Charging Gas F-12 to Water Cooler 40/80 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed. |
| 166 | Supply & Charging Gas F-12 to Deep Freezer 320 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed. |
| 167 | M&L Push Cock 15mm bore (dia) Brass Chromium plated, high pressure, screwed down for Socket/ Unions or GI Pipe including Taking down/ out unserviceable Push Cock, complete all as specified and as directed.MAKE : JAINSON/ NIXON or equivalent as approved by GE |
| 168 | M&L PVC Drain Pipe 32mm bore (dia), Heavy duty of Length 1.00 Metre with 2 Nno. Galvanized Adjustable Clamps, Providing necessary Connections including Taking down/ out unserviceable Drain Pipe, complete all as specified and as directed. |
| 169 | M&L PVC Float Valve Assembly 15mm bore (dia) comprising Valve Assembly, Aluminum Rod, PVC Ball, suitable Water Cooler/ Desert Cooler including Taking down/ out unserviceable Float Valve Assembly, complete all as specified and as directed. |
| 170 | M&L PVC insulated, Sheathed Copper Conductor multi-stranded Cable of size 40/.0076, 3 Core (Colour White or Black) and Providing Electric Connection including Taking down/out unserviceable Cable of any description, complete all as specified and as directed. |
| 171 | EARTH WORKS |
| 172 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Pipe Line, Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 173 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 174 | Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Water Pipe Line, CableLine with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed. |
| 175 | Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 176 | REPAIRS/MAINT TO EXTERNAL WATER SUPPLY |
| 177 | Taking down/ up Galvanised Steel Tubing 15mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed. |
| 178 | Taking down/ up Galvanised Steel Tubing 20mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed. |
| 179 | Taking down/ up Galvanised Steel Tubing 25mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed. |
| 180 | Taking down/ up Galvanised Steel Tubing 63mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed. |
| 181 | Taking down/ up Galvanised Steel Tubing 100mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed. |
| 182 | Supply & Laying/ Fixing Galvanised Steel Tubing 15mm bore (dia), medium grade, conforming to IS-1239 with all Connections/ Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any Other Situation, complete all as specified and as directed. |
| 183 | Supply & Laying/ Fixing Galvanised Steel Tubing 20mm bore (dia), medium grade, conforming to IS-1239 with all Connections/ Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any Other Situation, complete all as specified and as directed. |
| 184 | Supply & Laying/ Fixing Galvanised Steel Tubing 25mm bore (dia), medium grade, conforming to IS-1239 with all Connections/ Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any Other Situation, complete all as specified and as directed. |
| 185 | Supply & Laying/ Fixing Galvanised Steel Tubing 100mm bore (dia), medium grade, conforming to IS-1239 with all Connections/ Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any Other Situation, complete all as specified and as directed. |
| 186 | Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 20mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed. |
| 187 | Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed. |
| 188 | Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 63mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed. |
| 189 | S&F Bib Tap 15mm bore (dia), Cast Copper Alloy, screwed down, High pressure, with Crutch or Butter-fly Handle, screwed Both Ends for Unions/ Sockets including Taking down/out Unserviceable Bib Tap of any description, complete all as specified and as directed. |
| 190 | S&F Gun Metal Globe/ Gate Valve 15mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 191 | S&F Gun Metal Globe/ Gate Valve 20mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 192 | S&F Gun Metal Globe/ Gate Valve 25mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 193 | S&F Gun Metal Globe/ Gate Valve 32mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 194 | S&F Gun Metal Globe/ Gate Valve 40mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 195 | S&F Gun Metal Globe/ Gate Valve 50mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed. |
| 196 | M&L Dismantling Joints of Flanged Pipe 80mm bore (dia) in Position and Removing Old Rubber or Fiber Gasket, Bolts and Nuts, etc., complete all as specified and as directed. |
| 197 | S&F GI Long Nipple suitable for GI Pipe 80mm bore (dia) having 150mm long with Nuts, Bolts and Rubber Gasket including Taking down/out unserviceable Long Nipple, complete all as specified and as directed. |
| 198 | M&L Cast Iron Butter-fly Valve 65mm bore (dia), Wafer type, Flanged and drilled both Ends, ISI marked, conforming to IS:13095 with all Jointing Materials such as suitable size Mild Steel Nuts, Bolts, GI Washers, Rubber Gasket, etc. and Testing against Leakage including Taking out/ down Unserviceable Butter-fly Valve, complete all as specified and as directed. |
| 199 | M&L Cast Iron Butter-fly Valve 80mm bore (dia), Wafer type, Flanged and drilled both Ends, ISI marked, conforming to IS:13095 with all Jointing Materials such as suitable size Mild Steel Nuts, Bolts, GI Washers, Rubber Gasket, etc. and Testing against Leakage including Taking out/ down Unserviceable Butter-fly Valve, complete all as specified and as directed. |
| 200 | S&F Cast Iron Air Release Valve suitable for GI Pipe 80mm bore (dia) with Double Chamber, conforming to IS:14845 with all Jointing Materials including Taking out/ down Unserviceable Air Release Valve, complete all as specified and as directed. |
| 201 | M&L Cast Iron Non-Return Valve 80mm bore (dia) with all Jointing Materials including Taking out/ down Unserviceable Non-Return Valve, complete all as specified and as directed. |
| 202 | M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed. |
| 203 | M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed. |
| 204 | M&L Construction Brick Masonry Valve Chamber of Size 45x45x45 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed. |
| 205 | M&L Construction Brick Masonry Valve Chamber of Size 90x90x90 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed. |
| 206 | Dismantling Wrought or Mild Steel Works of any description not otherwise provided for, complete all as specified and as directed. |
| 207 | M&L Mild Steel Work such as Bracings, Supports, Clamps and Back Plates, etc., fabricated from Structural Steel Sections including necessary Welding, Bending Cold or Hot, Drilling Holes for Bolts, in any shape or size as indicated or directed including applying Two Coats of Aluminium Paint over a Coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed. |
| 208 | M&L Mild Steel Screw Bolts (machine made) with Hexagonal or Square Heads at One End and screwed the Other, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, Length of Bolt of existing Sizes, complete all as specified and as directed. |
| 209 | M&L Dewatering Water from Pressed Steel Storage Water Tank 50000 Litre capacity, having 3.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls and Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : XX.XX.XXXX\" i.e. Date of Cleaning on the Front/ Road Side Face of the Tank, complete all as specified and as directed.NOTE :-(a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.(b) Cleaning of Steel Storage Water Tank will be carry out for 2 Times within the Contract Period. |
| 210 | M&L Dewatering Water from Pressed Steel Storage Water Tank 80000 Litre capacity, having 3.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls and Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters \"TANK CLEANED ON : XX.XX.XXXX\" i.e. Date of Cleaning on the Front/ Road Side Face of the Tank, complete all as specified and as directed.NOTE :-(a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.(b) Cleaning of Steel Storage Water Tank will be carry out for 2 Times within the Contract Period. |
| 211 | M&L Pareparing Surfaces of Pressed Steel Storage Water Tank 50000 Litre capacity having 3.00 Metre High Steel Stagging and Removing Rust, etc. by Rubbing with Wire Brush, etc. from Outer Walls and Steel Stagging and applying Two Coats of Aluminium Paint on Outer Surface Area of Tank and Steel Stagging and applying One Coat of Black Bituminous Paint (suitable for Drinking Water Purpose) to Inside Portion of Storage Water Tank and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed.NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. |
| 212 | M&L Pareparing Surfaces of Pressed Steel Storage Water Tank 80000 Litre capacity having 3.00 Metre High Steel Stagging and Removing Rust, etc. by Rubbing with Wire Brush, etc. from Outer Walls and Steel Stagging and applying Two Coats of Aluminium Paint on Outer Surface Area of Tank and Steel Stagging and applying One Coat of Black Bituminous Paint (suitable for Drinking Water Purpose) to Inside Portion of Storage Water Tank and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed.NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. |
| 213 | M&L Preparing Surfaces of Iron Removal Plant 5500 GPH Capacity by rubbing of Surfaces with Wire Brush and removing rust, etc. from the Outer Surfaces of Iron Removal Plant and applying Two Coats of Aluminium Paint on Outer Area of Iron Removal Plant and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed.NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. |
| 214 | REPAIRS/MAINT TO PUMPS & MOTORS |
| 215 | M&L Lifting of Submersible Pump & Motor Assembly 7.5 HP capacityalongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed. |
| 216 | M&L Removing Submersible Pump & Motor Assembly 7.5 HP capacity to AGE E/M Store Yard at ALONG, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed.NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as \"Supply only\" under relevant Items.Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate.(b)Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department.(c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate.(d)Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item. |
| 217 | M&L Dismantling Submersible Motor 7.5 HP capacity, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed. |
| 218 | Supply only PVC insulated, sheathed Stranded Copper Conductor Water Proof Cable, Flat, Cross-sectional Area 6.0 Sqmm, 3 Core, 1100 Volt grade, conforming to IS:694 for suitable for Sumbersible Pump & Motor Assembly 7.5 HP capacity, complete all as specified and as directed. |
| 219 | M&L Lowering down Submersible Pump & Motor Assembly 7.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed.NOTE : Serviceable Materials viz Column Pipes and Other Materials, etc. (obtained from Item No. 7.01 here-in-before) keet in Safe Custody will be reuse. Sumbersible Cable will be replaced with New Cable and the same will be Measured and Paid separately under appropriate Item as \"Supply only\". |
| 220 | M&L Taking out existing Mono Block Pump Set 10 HP/ 20 HP capacity for Minor Repairs, Replacement of rusted Bolts, Nut, Washers with New One of existing Size, Greasing Pump Set for Smooth Functioning and Reinstalled the Pump in the same Position after repaired, complete all as specified and as directed. |
| 221 | M&L Opening Strip of Monoblock Pump Set 10 HP capacity, Removing Mono-block Pump Set to AGE E/M Store Yard at ALONG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Pump Set as required, Transporting defective Pump Set to nearest Workshop to carry out Repairing/Rewinding, Dismantling Pump Set, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the same and Testing for Smooth Fucntioning after Rewinding, Transporting Back to Worksite after Repaired, Reinstallation and providing all Connection, Testing in presence of JE/Engineer-in-Charge, complete all as specified and as directed. |
| 222 | M&L Opening Strip of Monoblock Pump Set 20 HP capacity, Removing Mono-block Pump Set to AGE E/M Store Yard at ALONG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Pump Set as required, Transporting defective Pump Set to nearest Workshop to carry out Repairing/Rewinding, Dismantling Pump Set, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the same and Testing for Smooth Fucntioning after Rewinding, Transporting Back to Worksite after Repaired, Reinstallation and providing all Connection, Testing in presence of JE/Engineer-in-Charge, complete all as specified and as directed. |
| 223 | M&L Sealed Ball Bearing (No. 6307 or as per existing/approved), suitable for Mono Block Centrifugal Pump Set 10/20 HP capacity and Repairing Shaft for Bearing hoisting for Pump Set including Taking out unserviceable Bearing from Pump Set, complete all as specified and as directed.MAKE : NBC/SKF/TATA |
| 224 | M&L Sealed Ball Bearing (No. 6308 or as per existing/approved), suitable for Mono Block Centrifugal Pump Set 10/20 HP capacity and Repairing Shaft for Bearing hoisting for Pump Set including Taking out unserviceable Bearing from Pump Set, complete all as specified and as directed.MAKE : NBC/SKF/TATA |
| 225 | M&L Parparing Surfaces of Machineries, Pump Sets and Removing rusts, etc. by rubbing with Wire Brush and applying Two Coats of Synthetic Enamel Paint (1st quality/grade) with Spray Painting Machine, complete all as specified and as directed. |
| 226 | S&F Pressure Gauge Diaphram type range 0-7 Kg/Sq Cm including Taking out/ down Unserviceable Pressure Gauge, complete all as specified and as directed. |
| 227 | S&F Automatic Star Delta Starter 10 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed.MAKE : BCH/ HAVELLS/ L&T |
| 228 | S&F Automatic Star Delta Starter 20 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed.MAKE : BCH/ HAVELLS/ L&T |
| 229 | REPAIRS/MAINT TO LT EXTERNAL ELECTRIFICATIONS |
| 230 | Dismantling unserviceable Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed.NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately. |
| 231 | Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed. |
| 232 | Taking down unserviceable/rusted GI Earth Wire, Cradles Guards of any size and shape at any Position from LT Electric Poles of any size and capacity, complete all as specified and as directed. |
| 233 | Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any size and capacity, complete all as specified and as directed. |
| 234 | Dismantling Stay Assembly complete of any description, complete all as specified and as directed.NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately. |
| 235 | Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc., complete all as specified and as directed.NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items. |
| 236 | M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed. |
| 237 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed. |
| 238 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork, complete all as specified and as directed. |
| 239 | M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed.NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items. |
| 240 | M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed. |
| 241 | S&F Pin type Insulator 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed. |
| 242 | S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 150mm High and 150mm dia including Galvanised Mild Steel Straps of Section 38x5mm, 20mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 11000 Volt including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed. |
| 243 | S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm including Taking down unserviceable Insulator from Electric Pole, complete all as specified and as directed. |
| 244 | M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed. |
| 245 | M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed.NOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge. |
| 246 | M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed. |
| 247 | S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed. |
| 248 | M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp 7/3.15 Mild Steel Galvanised Stay Wire, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles, 16mm dia Mild Steel Galvanised Stay Rod and Mild Steel Galvanised Stay Plate all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed.NOTE : Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items. |
| 249 | M&L Painting LT Electric Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with the Strips 300mm high around the Pole with Two different Colours SyntheticEnamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed. |
| 250 | Supply & Laying/ Fixing XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 6.0 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 251 | Supply & Laying/ Fixing XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 252 | Supply & Laying/ Fixing XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 16 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 253 | Supply & Laying XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 25 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 254 | Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 35 Sqmm, 3½ Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 255 | Supply & Laying XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 70 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 256 | Supply & Laying XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 120 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 257 | S&F Stright Through Joint with Jointing Kit suitable for 1100 Volt grade UG LT PVC insulated sheathed, armoured, Cable with Aluminium Conductor, Cross-sectional area 16 Sqmm 4.0 Core to 95 Sqmm 3½ Core complete with all Accessories, complete all as specified and as directed. |
| 258 | Supply & Laying HDPE Double Wall Corrugated (DWC) High Density Polythene Pipes of Outer Dia 40mm & Inner Dia 32mm, having corrugation on the Outer Wall and Plain surface on the Inner Wall, conforming to IS:14930 (Part I & II), cut to length as per Site Requirements for protection of UG Cable/ in PCC including cutting Floors, etc. and Making Good the Same with Original Specification to match the existing adjoining Surfaces, etc., complete all as specified and as directed. NOTE : Quoted Rate is inclussive of All accessories for fixing of DWC Pipe with Walls, Roofs, Cable Tray, etc. |
| 259 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. |
| 260 | Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed. |
| 261 | REPAIRS/MAINT TO LT PANEL BOARDS & EARTHING |
| 262 | S&F MCCB 63 Amp 3 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out unserviceable MCCB, complete all as specified and as directed. |
| 263 | S&F MCCB 100 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out unserviceable MCCB, complete all as specified and as directed. |
| 264 | S&F MCCB 160 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out unserviceable MCCB, complete all as specified and as directed. |
| 265 | S&F MCCB 200 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz, Adjustable Thermal & Fixed Magnetic type and connecting with Incoming & Outgoing Connections including Taking down/out unserviceable MCCB, complete all as specified and as directed. |
| 266 | S&F MCCB 400 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out unserviceable MCCB, complete all as specified and as directed. |
| 267 | S&F On Load Change Over Switch (Side Handle) in Sheet Metal Enclouser, 63 Amp rating, 4 Pole, 415 Volt, conforming to IS:13947 (Part-I & II) and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 268 | S&F On Load Change Over Switch (Side Handle) in Sheet Metal Enclouser, 100 Amp rating, 4 Pole, 415 Volt, conforming to IS:13947 (Part-I & II) and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 269 | S&F On Load Change Over Switch (Side Handle) in Sheet Metal Enclouser, 125 Amp rating, 4 Pole, 415 Volt, conforming to IS:13947 (Part-I & II) and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 270 | M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed. |
| 271 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connectedto GalvanisedEarth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. |
| 272 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. |
| 273 | REPAIRS/MAINT TO DG SETS |
| 274 | M&L Repairs/Maint & Servicing of DG Set 62.5 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:-(a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings.(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Sl No. 5.02 to 5.11 here-in-after are Provisional only) are will be Measured & Paid as \"Supply only\" under appropriate Items. |
| 275 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 276 | Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 277 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 278 | Supply only Controler Model No. KG934/GC 1202 (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 279 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 280 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 281 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 282 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 283 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 284 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 285 | M&L Repairs/Maint & Servicing of DG Set 100 KVA capacity of MAKE : ASHOK LAYLAND, complete all as specified and as directed comprising with the following Works:-(a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings.(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Sl No. 12.13 to 12.22 here-in-after are Provisional only) are will be Measured & Paid as \"Supply only\" under appropriate Items. |
| 286 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 287 | Supply only AVR (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 288 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 289 | Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 290 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 291 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 292 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 293 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 294 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 295 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 100 KVA capacity, complete all as specified and as directed. |
| 296 | M&L Asbestos Rope (as per existing/ as approved) including Taking down/out unserviceable Asbestos Rope, complete all as specified and as directed. |
| 297 | M&L Battery Terminal of Copper/Brass (as per existing/ as approved) and connected including Taking down/out unserviceable Battery Terminal, complete all as specified and as directed. |
| 298 | S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed. |
| 299 | M&L Cleaning of Radiator of any capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed. |
| 300 | M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed. |
| 301 | Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed.MAKE : KIRLOSKAR |
| 302 | Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed.MAKE : CASTROL CRB Plus |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy