Housing Urban and Rular Development Government Departments Closing in 0 days TDR #28777365

Construction Of Bank Building For Cuttack Central Co-Operative Bank At Jajpur Building Work

Issued by Government Departments · Panikoili, Odisha
Tender Value
2.13 Crore
Estimated cost
Bid Submission
23 Aug 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panikoili → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Bank Building For Cuttack Central Co-Operative Bank At Jajpur Building Work

BOQ

Name of Work: Construction of Bank Building for Cuttack Central Co-operative Bank at Jajpur
Sl. No. Item Description
1CIVIL WORKS(PART-I) Earth wowrk in excavation of foundation trenches in ordinarysoil upto required depth including dressing levelling the bed and deposited the excavated earth away from work site with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge
2Construction of single under reamed pile foundation of 375mm dia and8.0mlongwith RCC M-25 using crushed broken hard granite chips of 20mm and down graded with required design with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge (excluding reinforcement)
3Construction of single under reamed pile foundation of 300mm dia and6.0mlongwith RCC M-25 using crushed broken hard granite chips of 20mm and down graded with required design with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge Boundary wall
4Filling foundation and plinth with good quality river sand incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
5Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
6Cement concrete (1:2:4) in foundation and plinth using 12mm size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
72.5cm thick grading concrete of proportion (1:2:2) over roof slab using 4.7mm size chips of approved quality including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeTerrace floor
8Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor in Foundation and Plinth
9Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor Superstructure
101st floor
112nd floor
12Parapet Wall
13RCC work ofM-25 Grade with 20mm and down graded size crusher brokengranite metal mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge. Pile CapGF
14Grade and Plinth BeamGF
15RCC Wall for lift room
16ColumnGF
171st floor
182nd floor
19Lintel(GF)
201st floor
212nd floor
22Roof Beam (GF)
231st floor
242nd floor
25Roof slab(GF)
261st floor
272nd floor
28StaircaseGF
291st floor
30RCC work ofM-30 Grade with 20mm and down graded size crusher brokengranite metal mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge.Plinth Beam and RCC Wall
31Raft (For strong room)
32Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor
331st floor
342nd floor
35Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
361st floor
372nd floor
38Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge (GF)
391st floor
402nd floor
41Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside ceiling surface of brick walls with watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge (GF)
421st floor
432nd floor
44Providingfitting and fixing of Granitetiles in floors of approved makeover 25mm thick bed of cement mortar(1:1)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge(G,F)
451st floor
46Providingfitting and fixing of Vitrified tiles in floors & tread, of approved makeover 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge(G,F)
471st floor
48Providingfitting and fixing of Vitrified tiles in dadoos, skirtingover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge(G,F)
491st floor
50Painting two coats withapproved Plastic Emulsion paint over a coat of primerto outside wallincluding sand papering, polishing the surface, cost, conveyances ofmaterials and cost of all labour TandP etc complete as perGFspecification and direction of Engineer in charge (Outside surface) (Priming and Painting)GF
511st floor
522nd floor
53Painting two coats withapproved Plastic Emulsion paint over a coat of primer and puttyto inside wallincluding sand papering, polishing the surface, cost, conveyances ofmaterials and cost of all labour TandP etc complete as perGFspecification and direction of Engineer in charge (Inside surface) (Putty, primer, painting) GF
541st floor
552nd floor
56Providing well dressed seasoned sal wood choukaths including cost, conveyance, taxses, cost ofall labour, T&P etc complete as per specification and direction of Engineer in chargeInall floor
57Solid Door with B/S laminated - Providing, fitting and fixing ofapproved make 32mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. Baan Code-LKYPDC527), 125x75x3mm (code no-7912) SS201 hinges, etc.of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge.In all floor
58Painting two coats withapproved Synthetic Enamelpaint over a coat of primerto wood workincluding sand papering, polishing the surface, cost, conveyances ofmaterials and cost of all labour TandP etc complete as perGFspecification and direction of Engineer in charge (Woodwork)
59Irom Work(Grill and Gate)
60Supplying and fitting fixing of Un-plasticized Poly Vinyl Chloride (UPVC) (FENESTA/NICL/VEKA LTD) Casement Door-60 series duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5mm for outer frames, 102mmx60mmx2.25mm for casement Door sash profile and 74mmx60mmx2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanized upto 50 microns of minimum thickness of 2.00mm prefabricated and welded through fluxion welding the door sash shall be fitted with 12mm thick WPC Board of Greenly make duly fixed with EPDM weathering seal resistant accessories the clipping locking system made of aluminum 1 No. per set of sashes and the system is to be installed at the site using anchor fasheners,l silcon rubber sealant easy glazing/ deflating at site etc. including cost and conveyance of all materials accessories, labour charges, materials and conduct conforming to ASTMD 63-14 EN-477-95 and other applicable
61Ventilator
62Supplying, fitting & fixing in all floors of M.S.grills for door and window and gates, with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials labour, cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost In all floor
63Boundary Wall, Gate
64Providing, Fitting & Fixing of Stainless steel of 304 grade in hand railing of 50mm outer diameter of 2mm thick of approved Quality & Specification with balustrade of size 32mmX32mmX2mm square pipes in rows including Cost of all Materials, Labour for fabrication, buffing & polishing, cost of all fixtures etc. Complete and as per specification & direction of Engineer-in-charge. All floors
65Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
66Providingand fixing of Strong room Godrej made Class-II Strong room door with grill gate (Class-B), Air ventilater Exhaust fan and Veagewith all accessories and complete including transport, fitting labour hardwareas per specification & direction of the Engineer-in-charge
6716mm thick decorative cement plaster (1:6) over brick or stone masonry including all cost, conveyance, cost of all labour, T&Petc, complete as per specification & direction of the Engineer-in-charge
68Providingerecting, welding of GI made Cow catcher made of 90 mm Circular hollow section with 120mm c/c including all materials and transportation excluding GST etc. complete as per specification and direction of Engineer-in-charge
69Providingfitting and fixing of Cement Concretetiles in floors of approved makeover 25mm thick bed of cement mortar(1:1)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge(G,F)
70Dismantling brick or stone masonry in lime or cement mortar under 3m height including stacking the useful materials for reuse and removing the debries with 50m lead etc complete as per specification and direction of Engineer in charge.
71Dismantling Cement concrete including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
72Dismantling RCC column beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
73Dismantling and removing RCC chajja, shelves, fins and parapet including stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
74Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
75Dismantling and removing old cladding from walls including racking out joints 12mm deep and stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
76Dismantling and removing Doors, windows and ventilators including removal of frame, hinges and stacking the useful materials for reuse and removing the debries within 50m lead etc complete as per specification and direction of Engineer in charge
77E.I. Works:-Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Group C
78Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. Average Length: 3mtr
79Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. Group B
80Recessed wiring to Twin control light pointwith 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Group C
81Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge.
82Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. Group C
83Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge.
84Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge.
85Recessed wiringfor A.C/ Power socket outletwithindustrial type socket outlet,plug top and metal chained cover in sheet steel enclosure,20A/32A SP MCBincluding all accesories and connection as per direction of Engineer in Charge.
86Recessed wiring to submain in 4 x 16sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduitalong with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.( For GF AC DB)
87Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For GF PDB &1FAC+PDB )
88Recessed wiring to submain in 4 x 6 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For GF LDB & CDB ,1F LDB & CDB)
89Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.( For ELDB GF & 1F)
90Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For A.C )
91Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From DB to Switch Board & 2x5A SOCKET POINTS & 15ASOCKET POINTS & STREET LIGHT POINTS)
92Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For Switch Board Looping & AC IDU SOCKET POINT )
93Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 8 way SPN Distribution Boards suitable for 230 V, single phase, 2 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-25ADPRCCB (30mA)Outgoings-6-32 A SP MCB- 6 Nos, ( ELDB )
94Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-25AFPRCBO (100mA)Outgoings-6-32 A SP MCB- 12 Nos, ( 1F.CDB)
95Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40AFPRCBO (100mA)Outgoings-6-32 A SP MCB- 12 Nos, (For G.F PDB & 1F.AC+PDB)
96Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted6 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-32AFPRCBO (100mA)Outgoings-6-32 A SP MCB- 18 Nos, (For GF LDB ,GF CDB & 1F LDB)
97Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63AFPRCBO (100mA)Outgoings-6-32 A SP MCB- 12 Nos,(For AC DB)
98Supply and Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5C 70 sq.mm Al.direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. /on surface as required.
99Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.- 3.5C x70 sq.mm
100Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.Siemens Grey Powder coated CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete. Legrand / Schneider/ L&T-G.FLOOR Panel with 100A 4P MCCB -1 No as incomer , 63A 4P MCB -4 Nos , 40A 4P MCB -4 Nos, 32A 2P MCB -6 Nos & ANALOG TIMER-3 with DP Power contactorNos as Outgoing with E.C Busbars with 1no 50KA 4Pole VSD along with 1no 32A 4P MCB .
1011ST.FLOOR Panel with 100A 4P MCCB -1 No as incomer ,63A 4P MCB -3 Nos , 40A 4P MCB -4 Nos& 32A 2P MCB -3 Nos as Outgoing with E.C Busbars with 1no 50KA 4 Pole VSD along with 1no 32A 4P MCB .
102Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.- Wall / Ceiling mounted indoortype BATTENLED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZ01X024XW or equivalent.
1039W PAG LED Lamp Equiv. to JAQUAR.
104Surfacemounted indoortypeLED Luminaire with LED Lamp Similar to JAQUAR Cat No. LNRO02R018SW or equivalent.
105Supply &fixing ofStreet lightFixture suitable for LEDlamp Equiv. to JAQUAR LTRUMP0030XW or equivalent.
106Supply &fixing of Decorative POST TOPLED FixtureWith Die Cast Aluminum Body & heat resistant toughened glass diffuser suitable for JAQUAR Cat No. LGTP05X030XW or equivalent.
107Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. (Khaitan/Usha/Crompton Greaves)
108Supply, Installation, testing and commissioning of high speed wall fan of 400 mm sweep 900 rpm on partition wall/ brick wall , making good the damage complete, connection, etcas required.(Khaitan/Usha/Crompton Greaves)
109Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.(Khaitan/Usha/Crompton Greaves)
110Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
111Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
112Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
113Supply, delivery, installation, testing and commissioning of Early Streamer Emission (ESE) Lightning protection Airterminal compling with NFC - 17-102 standards similar to ABB Model Pulsar-30 or equivalent complete as required and as per direction of Engineer-in-charge
114Supply, delivery, installation, testing and commissioning of support structure for Lightning Protection Air Terminal fabricated out of GI pipealong with base plate, Guy wire clamping system, termination arrangement for the down conductor complete as required and as per direction of Engineer-in-charge.
115Supply, delivery, installation, testing and commissioning of Lightning strike counter working electro mechanically without any power supply complete as required and as per direction of Engineer-in-charge.
116Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
117Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
118Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
119Recessed wiring to television pointwithclip in type modular television socket ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
120Recessed wiring to telephone pointwithclip in type modular telephone socket (RJ 11) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
121Recessed wiring to LAN pointwithclip in type modular lan socket (RJ45) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
122Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
123Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
124Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required.
125Supplying and drawing TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protectedin the existing surface / recessed PVC conduit as required.
126Supplying and drawing UTP 4 pairLAN cat-6 cable in the existing surface / recessed PVC conduit as required.
127Supply ,Installation,Testing & Commissioning of 1nos100 KVA 3star rated, AL wound Transformer,H.T. metering unit and 11/0.4kv substation of 9mtr RS joist pole with all the necessary equipments and arrangments.
128Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
129Earthing with G.I earth pipe 4.5 meter long 40 mm diaincluding accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required
130Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
131Supplying and laying 25 mm x 6 mm G.I earth stripat 0.5 meter below grond level as strip earth electrode including connection / terminating with nut, bolt ,spring washeretc. as required. ( Jointing shall be done by overlapping and with 2sets of G.I nut, bollt & spring washer spaced at 50mm)
132Supply, installation,testing & commissioning of wall/floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-65 protection with hinged and lockabale doors.Siemens Grey Powder coated CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom/topas required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. -MAIN.FLOOR Panel with 200A 4P ONLOAD CHANGE OVER SWITCH &200A 4P MCCB -1 No as incomer ,100A 4P MCCB -4 Nos,& 32A 2P MCB -3 Nos as Outgoing with E.C Busbars with 1no 65KA 4PoleVSD along with 1no 32A 4P MCB .
133Supply and Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5C 150 sq.mm Al.direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. /on surface as required.
134Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.- 3½ X 150 sq. mm (38mm)
135Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
136Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
137Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
138Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
139Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.
140P.H. Works:-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge.20mm dia CPVC pipe - 20mm dia C- PVC pipeIn ground floor
141In First floor
14225mm dia C-PVC pipe groundfloor
143In First floor
14432mm dia C-PVC Pipe in ground floor
145In First floor
146Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.- 25mm dia PVC ASTM pipe (sch-80)Ground floor
147In Ist floor 25mm dia PVC ASTM pipe (sch-80)
148In 2nd floor over roofof F.F.
14940mm dia PVC ASTMpipe In G.F
150In first floor
151In 2nd floor over roof of F.F.
152Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mmthick wall
153Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.In ground floor
154Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In ground floor
155Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15mm dia CP bib cock CON-CHR-037KN(Jaquarmake )
15615 mm dia CP two way Bib cock CON-CHR-041KN(Jaquar make)
15715mm dia CP Health foucet (Con-ALD-CHC-573 Jaquar make)
15815 mm dia CP Long bodyBib cock( CON-CHR-107KN Jaquar make )
15915mm dia CP angle stop cock(CON-CHR-053KN Jaquar ) Make
16020mm dia CP concealed stop cock(CON-CHR-069KN Jaquar)Make
16115mm dia C.P. bottle trap ALD-CHR-769L300X190 Jaquar make
16215 mm dia CP pillar cock auto closing system(Jaquar)-PRS-chr-031
16315mm dia pvc connection pipe
16425mm dia Brass full way valve (ShaktiMake)
16540mm dia Brass full way Valve(ShaktiMake)
16615mm dia CP flange
16715mm dia CP extension piece
168Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge 15mm dia CP revolving shower ( Plaza make )
169Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge10 litres capacity pvc low level cistern with 32mm dia CP long flush bendSlimline white
170Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge On the roof of first floor 2000litre capacity water storage tanks
171Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe(Ashirbad / Supreeme )
172110mm U-PVC door crosstee
173110mm U-PVC door tee
174110mm U-PVC door bend
175110mm U-PVC plain bend
176110mm U-PVC Plain tee
177110mm dia U-PVC \"P\" trap
178110mm dia U-PVC Plain Shoe Bend
179110mm dia U-PVC offset with out ear
180110mm dia U-PVC cowl
181125mm dia CP grating
182Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge 250mm to 375mmthick wall
183Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
184Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge580mm size Orissa pan (Parryware / Nycer make )
185Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware / Nycer make )
186Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Parryware /Hindware make )
18715mm dia urinal spreader
18832mm dia C.P. dome waste
189Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge . 600x450x250 mm stainless Steelkitchen sink with drain board(jayna make )
190Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. 550mmx400mm size wash hand basin with halfpedestal(Hindware )No.91049+91115
191(a)W.H.Basin(Under counter-Oval shape)-Jaquar make-Cat. No-CNS-WHT-705(Excluding pillar cock)
192Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thickon 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge . 600mmx450mm size B.E mirror x minimum 5mm thick(Design Mirror )
193Big Size Mirror
194Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf with CP guard rails(Jaquar)No.ACN-SSF-1171N
195Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail(Jaquar)No.ACN-ABR-1111NM
196C.P. Ring Towel Rail(Jaquar)No.ACN-SSF-1121BN
197Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder
198Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor
199Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
200Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
201InIst floor
202Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
203InIst floor
204Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning for skirting including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge InIst floor
205Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.
206Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.
207Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
208In first floor
209Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height
210In firstfloor
211Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge- In groundfloor
212In firstfloor
213Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge - In groundfloor
214In firstfloor
215Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 30 cm. x 30 cm. Kajaria / Somany / Johnson to be pree approved .In ground floor
216InIst floor
217Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge.45cm. x 30cm. Kajaria / Somany / Johnson to be pree approved .In ground floor In ground floor
218InIst floor
219Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In ground floor
220In first floor
221Supplying all materials, labour, T&P and providing Graniteslab urinal partition wall including cutting grooves in wall and making good the damages,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge
222Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make)
223Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.Aquaguard 120 PSS RO+UV
224EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia
225160mm dia
226Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
227Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
228---- do --- addl depth of 0.15m upto 0.90m
229R.C.P.C.Manhole Cover
230Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
231R.C.P.C.Manhole Cover
232Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.40m dia x 2.00m deep soakway pit
233Construction of 50 users RCC Septic tank( 4 nos for 4 Block).Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge.
234Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
235Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
236Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge
237Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
238RCC beam,Column, girders and bressmer etc
239Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
240Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
241Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside/outside)
242Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside)
243Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
244Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
245Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge 110mm diameterU PVC SWRpipe(Oriplastmake )
246110mm dia U-PVCH.R.bend
247110mm dia U-PVCCowl
248Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
249Sinking of 150mm dia tubewell through hand boring (water jet ) method (1 No) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
250Supplying alllabour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge
251Supplying alllabour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres
252Supplying alllabour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm diafrom 0 to 360 metres
253Reaming 150mm to 200mm dia from 0 to 360 metres
254Reaming 200 mm to 250mm dia from 0 to 360 metres
255Supplying alllabour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres
256Supplying all labour T&P and grouting with cementslurry for salinesealing intheborearoundthe 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
257Supplying alllabour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge - 150mm dia PVC casing pipefrom 0 to 360 metres
258Cost of 150mm dia PVC ASTM pipe (sch-80)
259Cost of 150mm dia PVC cutting slut
260Cost of 150 mm dia C.I. cutter plug
261Cost of bentonite powder
262Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge
263Cost and Conveyance of Gravel
264Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge
265Cost and Conveyance of sand
266Supplying all labour T&P and grouting with cementslurry for sanitary sealingintheborearoundthe uppermost 3 metres of150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
267Cost of Cement
268Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor
269Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
270DOL Control panel
27140mm dia steel short piece
272Well cap
27350mm size CI bracket
2742.50sqmm flat cable
27520mm dia rigid UPVC pipes
276Steel rope with cover
27732mm dia HDPE pipe
278Labour charges for lowering including transportation

AI Tender Summary

OUR REF NO 28777365
AUTHORITY Government Departments
TENDER VALUE 2.13 Crore
LAST DATE 23-08-2021
Authority
Authority Name Road And Building Department
Work Description Construction Of Bank Building For Cuttack Central Co-Operative Bank At Jajpur Building Work
Basic Detail
Tender No ACE.Ctc.(RandB)12/2021-22
Bidding Type Tender
Location
City Panikoili
State Odisha
Key Dates
Publish Date 07 Aug 2021
Submission Date 23 Aug 2021
Open Date 24 Aug 2021
Finance
Tender Value 2.13 Crore
Tender Fee 10000
EMD Ref. Documents
Exemption Not Available
Document List
2d5c56a5-b63f-4db3-b7b6-a8d3d110e572.html
BOQ_362275.xls
DTCN.pdf
Office_Memorandum.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 23, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 24, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2d5c56a5-b63f-4db3-b7b6-a8d3d110e572.html

xls

BOQ_362275.xls

pdf

DTCN.pdf

pdf

Office_Memorandum.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail