}

Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - B, JIPMER PUDUCHERRY-Puducherry

Jawaharlal Institute Of Post Graduate Medical Education And Research-JIPMER has published Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - B. Submission Date for this Tender is 25-09-2021. Coats and Jackets Tenders in JIPMER PUDUCHERRY Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

28774282
Corrigendum : Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - B
Open Tender
Indian
Puducherry
JIPMER PUDUCHERRY
25-09-2021

Tender Details

Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - Blood Flow Rate Spv - Static Priming Volume, Cvr - Cardiotomy Venous Reservoir. Pv - Priming Volume, Bhpsc - Biocompatible Hydrophilic Polymer Surface Coating, He - Heat Exchanger.Ss - Stainless Steel Spr - Sample To Be Provided , Membrane Oxygenator-Large Adult- Type A Msa = 1.7 To1.8M², Max. Bfr = 8L / Min, Spv= 220Ml, Cvr = 4500Ml, Surface Must Be Coated, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Large Adult- Type B Msa = 1.4 To 1.8M², Max Bfr =6 L / Min, Spv = 185Ml, Cvr = 4500Mlcoated Surface -Polyurethane He, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Large Adult- Type C Msa = 1.4 To1.8M², Max Bfr = 6 L / Min, Spv = 185Ml, Cvr = 4500Ml, Integrated Arterial Filter, Surface Must Be Coated, Polyurethane He, Primary Pack Should Be Labelled.Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Small Adult- Type A Msa=1.3 To 1.5 M², Max Bfr= 5 L / Min, Spv = 175Ml, Cvr = 4000Ml. Biocompatible Surface Coating Preferable. Stainles Steel He, Primary Pack Should Be Labelled.Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Smalladult- Type B Msa = 1.3 To1.5 M², Max Bfr =5L / Min, Spv =295Ml, Cvr = 4000Ml. Integrated Arterial Filter, Ss-He, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Small Adult- Type C Msa= 1.5M², Max Bfr= 4 L / Min, Spv = 135 Ml, Hard Shell Reservoir Capacity 3000-3200Ml, Metal He.Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied.Spr , Membrane Oxygenator- Pediatric- Type A Msa = 1.1M², Max. Bfr 2.8 To3.5L / Min, Spv = 130Ml, Cvr = 2500Ml, Ss- He Integrated With Oxygenator. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator - Pediatric- Type B Msa = 0.8M², Max Bfr 2.1 -2.8 L / Min, Spv= 100Ml, Cvr = 1500Ml, Ss-He Integrated With Oxygenator. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Pediatric- Type C Msa = 0.67M², Max Bfr = 2 L / Min, Spv = 48Ml. Integrated He Of Terephthalate ( Pet ) Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Infant Msa = 0.5M², Max Bfr = 1.5 L / Min, Spv = 43Ml, Integrated Ss-He. Biocompatible Hydrophilic Polymer Surface Coating .Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Neonate Msa = 0.35M², Max Bfr= 1 L / Min, Spv = 38Ml, Integratedss-He , Coated Surface. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Dual Chambercvr Integrated With Arterial Filter Msa = 1.6 To 1.85M², Max Bfr -7 L / Min, Spv = 350Ml, Coated Surface, Two-Step Lipid-Leukocytes Depletion Cvr, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator -Adultmsa =1.8M², Max Bfr= 7 L / Min, Spv = 250 Ml. Cvr=4 Lit, Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator - Small Adult Msa =1.2M², Max Bfr= 5L / Min, Spv = 150 Ml. Cvr=3 Lit Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator-Pediatric Msa = 0.67M², Max Bfr Up To 4L / Min, Spv = 90 Ml. Cvr=2.5 Lit Diffusion Membrane Material Polymethyl Penteneprimary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator -Neonate Msa = 0.69M², Max Bfr=1.5 L / Min, Spv = 95Ml.Cvr = 1.5 Lit. Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Adulttype 1Msa =1.8M², Max Bfr= 7L / Min , Spv = 250 Ml, Rf-32 Or Flo Pump32centrifugal Pump Head, Diiffusion Membrane Ofpolymethylpentene.Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Adulttype 2 Msa = 1.8M², Max Bfr= 7 L / Min, Spv=250 Ml, Vaned Impeller Design Ofpump Head- Diffusion Membrane Material Polymethylpentene, - 3 / 8 Inch Inlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) & Sorin S5 ( Cp5 ) , Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Smalladulttype 1 Msa = 1.5M², Max Bfr= 5L / Min , Spv = 200 Ml, Rf-32 Or Flo Pump32 Centrifugal Pump Head, Diffusion Membrane Material Polymethylpentene , Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Smalladulttype 2 Msa = 1.5M², Max Bfr= 5L / Min, Spv = 200 Ml, Vaned Impeller Design Pump Head, Diffusion Membrane Material Polymethylpentene , 3 / 8 Inchinlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) & Sorin S5 ( Cp5 ) Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Pediatric Type 1Msa =0.69M², Max Bfr = 1.5.L / Min, Spv =90 Ml. Rf-32 Or Flopump32centrifugal Pump Head, Polymethylpentene Membrane, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Pediatric Type 2 Msa = 0.69M², Max Bfr= 1.5L / Min, Spv =90 Ml. Vaned Impeller Design Pump Head, Polymethylpentene Membrane, 3 / 8 Or 1 / 4 Inchinlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) &Sorins5 ( Cp5 ) . Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Hemofilter- Big Adult Msa = 1.4M², Pv = 80 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled.Spr , Hemofilter- Adult Msa = 1.1M², Pv=71 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter- Small Adult Msa = 0.71M², Pv = 65 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter -Pediatric Msa=0.3M², Pv= 35 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter-Infant Msa =0.1M², Pv= 20 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Arterial Filter - Adult Max Bfr=7 L / Min, Spv = 125 Ml, Pore Size-37Μm, Blood Port= 3 / 8 Inchbypass Loop& 3-Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Arterial Filter - Small Adult Max Bfr=4L / Min, Spv = 80 Ml, Pore Size-37Μm, Blood Port= 3 / 8 Inchbypass Loop & 3-Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Arterial Filter - Pediatric Max Bfr=2.5 L / Min, Spv = 40 Ml, Pore Size-32Μm, Blood Port=1 / 4 Inch. Bypass Loop & 3Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Custom Pack-Adult- Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Small Adult -Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Pediatrictubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Neonatal Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Ecmo Adult Tubing Set Custom Pack As Per The Jipmer2020 Circuit. Primary Pack Should Be Labelled. Spr . ( Contact Ctvs Dept For Figures ) , Ecmo Pediatric Tubing Set Custom Pack As Per The Jipmer2020 Circuit. Primary Pack Should Be Labelled. Spr . ( Contact Ctvs Dept For Figures ) , Cardio Plegia Delivery System ( Cpds ) - Reservoir Typeminimum 2-L Reservoir Capacity With At Least 4 X 1 / 4” Ports With Holder Primary Pack Should Be Labelled. . Spr , Cardio Plegia Delivery System ( Cpds ) -4:1 Type Pv= 30Ml, Max Bfr = 2.5 L / Min With 3-Way With Purge Line.Preferably Withgroved Stainless Steel He & 150 Μm Polyester Screen Filter.Primary Pack Should Be Labelled. Holder To Be Supplied. Spr , Centrifugal Pump Head -Adult Type 1 Vaned Impeller Design, 3 / 8 Inlet & Outlet With Housingto Fit The Centrifugal Console Of Heart Lung Machine Of Aps-I ( Terumo – Sarns ) & Sorin S5 ( Cp5 ) .Spr , Centrifugal Pump Head - Adult Type 2Priming Volume = 32Ml, 3 / 8 Inch Inlet & Outlet With Housingto Fit The Centrifugal Console Of Rotaflow ( Maquet ) . The Pump Head Should Bewithout A Metal Shaft Or Seal.Spr , Centrifugal Pump Head - Pediatrictype 1 Vaned Impeller Design, 1 / 4 Inlet & Outlet With Housing To Fit The Centrifugal Console Of Heart Lung Machine Of Aps-I ( Terumo–Sarns ) & Sorin S5 ( Cp5 ) . Spr , Centrifugal Pump Head - Pediatrictype 2 1 / 4 Inlet & Outlet With Housing To Fit The Centrifugal Console Of Rotaflow ( Maquet ) . The Pump Head Should Bewithout A Metal Shaft Or Seal. Spr , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) -30 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) 34 / 35 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) - 40 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) - 50 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Pressure Transducers -Single Type Forheart Lung Machine Sarns Heart Lung Machine And Aps-Iwith 200 Cm Pressure Line& A Pressure Cable Suitable For The Device And The Machine Has To Be Supplied Free Of Cost With Every100 Transducers Purchased-Spr , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size A -3 / 16 X 3 / 16. , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size B - 1 / 4 X1 / 4.. , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size C -3 / 8 X 3 / 8. , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size D -1 / 4 X 3 / 8. , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size E -3 / 8 X 1 / 2. , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size A-3 / 16 X 3 / 16 X 3 / 16 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size B-3 / 16 X1 / 4 X 1 / 4 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size C-1 / 4 X1 / 4 X 1 / 4 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size D-1 / 4 X1 / 4 X 3 / 8 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size E-3 / 8 X 3 / 8 X 3 / 8 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size F-3 / 8 X 3 / 8 X 1 / 4 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size G-1 / 2X 3 / 8X 3 / 8 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size H-3 / 16 X 1 / 4 X 3 / 8 , Htk Type - Single Shot Cardioplegiahistidine – Tryptophan – Ketoglutarate ( Htk ) Type.Cardioplegic Solution For Myocardial Protection For At Least 3 Hours After A Single Shot Of Cardioplegia.1 Litre , Htk Type - Single Shot Cardioplegiahistidine – Tryptophan – Ketoglutarate ( Htk ) Type.Cardioplegic Solution For Myocardial Protection For At Least 3 Hours After A Single Shot Of Cardioplegia.0.5Litre , Multiple Perfusion Adapter Setwith 4 Legs ( 3 Long +1Short Leg ) With Individual Tubing Clamps For Simultaneous Perfusion Of Venous Grafts And Aortic Root - With Femaleluer Inlet & Maleluer Outlets Preferably Withlength Of- At Least 10 ( Refer Fig. ) Spr. , Minimally Invasive Vascular Access Kitfor Femoral Arterial Cannulation For Cpb Orecmowithscalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F& 16 F / 18 F, Guidewire - 0.038 ( 0.965-Mm ) -100 Cm Long -Forcannulation - Spr , Minimally Invasive Vascular Access Kitfor Femoral Venous Cannulation For Cpborecmo With Scalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F And16 F / 18 F, Guidewire - 0.038 ( 0.965-Mm ) -180 Cm Long- Spr , Minimally Invasive Vascular Access Kitfor Jugular Venous Cannulation For Cpb Orecmo With Scalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F Guidewire - 0.025 ( 0.535-Mm ) -60 Cm Long-Forcannulation Spr , Dual Lumen Catheter13 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter16 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter19 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter20 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter23 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter27 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter31 F For Venovenous Ecmo With Insertionkit Having 210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 8Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 10Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 12Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 14Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 16Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 18Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 20Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 22Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 24Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 20F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 22F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 24F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 6F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 8F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 10F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 12F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 14F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 16F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 18F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar - Overal Length Of At Least 12 Inch Long Preferably With Guidewire. Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 20F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 22F - With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 24F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Venous Return Cannula - Single Stage -- Straight12fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight14fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight16fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight18fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight20fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight22fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight24fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight26fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight28fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight30fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight32fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight34fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight36fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight38fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 10Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 12Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 14Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 16Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 18Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 20Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 22Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 24Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal26fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 28Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula-Cuffedsingle Stage - 37F- Wirewound Bodyat Least35 Cm Longwithinflatable Cuff - Spr , Venousreturn Cannula-Two Stageflat Body- 28 / 36F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 29 / 29F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 29 / 37F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 32 / 40F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 36 / 46F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 34 / 46F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 36 / 51F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Threestage -Oval Body- 29 / 29 / 29 F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Threestage -Oval Body- 29 / 46 / 37 F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 8F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 10F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 12F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 14F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 15F Or 16F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 17F Or 18F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 19F Or 20F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 21F Or 22F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 23F Or 24F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 25F Or 26F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 8F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 10F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 12F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 14F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -15F-Or 16 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -17F-Or 18 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -19F-Or 20 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -21F-Or 22 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -23F-Or 24 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -25F-Or 26 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -27F-Or 28 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -29 F Or 30Fwith Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Cardio-Plegic Cannula-Antegrade 3F ( 18G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 4Fwith Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 5F ( 16G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 6F Or 7F ( 14G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 8F Or 9F ( 12G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 11F With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 4F With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 5F ( 16G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 6F Or 7F ( 14G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 8F Or 9F ( 12G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 11F With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegiacannula-Minimally Invasive Antegrade Typewithintroducer Needle Withstandard Tip With A Length Of At Least 30 Cm- Spr , Cardioplegiacannula - Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of12f ( 4Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula- Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of15f ( 5Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of18f ( 6Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula -Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of21f ( 7Mm ) & Tip Of 3 Mm-Spr , Cardioplegiacannula -Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of24f ( 8Mm ) & Tip Of 3.5 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of12f ( 4Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of15f ( 5Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of18f ( 6Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of21f ( 7Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of24f ( 8Mm ) &Tip Of 3.5 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Tapering Typewith Soft Self-Inflating Ballooon- Tip Tapering From 27F ( 9Mm ) To 8F ( 2.7Mm ) And Body Encapsulated With Malleable Wire- Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip -10F ( 3.3Mm ) Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip - 12F ( 4Mm ) Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip -14F ( 4.7 Mm ) - Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 Deg Angled Basket Tip -10F ( 3.3Mm ) Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 Deg Angled Basket Tip - 12F ( 4Mm ) Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype-80-90 Deg Angled Basket Tip -14F ( 4.7 Mm ) - Spr , Retrograde Cardioplegia Cannula ( Coronary Sinus ) Withsolid Stylet 13F -Withauto-Inflatable Cuff& Integral Stop Cock For Pressure Monitoring - Preferably Wirewound Body - Spr , Retrograde Cardioplegia Cannula ( Coronary Sinus ) Withsolid Stylet 15F -Withauto-Inflatable Cuff& Integral Stop Cock For Pressure Monitoring - Preferably Wirewound Body - Spr , Cardiac Suction Tip- ( Mini Sucker ) Soft Flexible Tapered Tip - 9F ( 3Mm ) - With Angled Shaft- Spr , Cardiac Suction Tip- ( Mini Sucker ) Soft Flexible Tapered Tip - 12F ( 3Mm ) - With Angled Shaft- Spr , Intra-Cardiac Suction Tip- Rigid - 20F ( 6.7Mm ) Fluted Pool Tip- With 16F ( 5.3Mm ) - Angled Metal Shaft At Least 15 Cm Long - Spr , Frazier Tip- Suction - Small & Short6f Tip & Shaft - About 7.5Cm Long - Spr , Frazier Tip- Suction - Small & Long 6F Tip & Shaft - About 15Cm Long - Spr , Frazier Tip- Suction - Large -10 F Tip & Shaft - About 10 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 1:20 Ftip Withmetal Weighted Perforated Pooltip& Flexible Tubingat Least 30 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 2:12 Ftip Withmetal Weighted Perforated Pooltip& Flexible Tubingat Least30 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 3:20 Ftip With Spring Encased Fluted Pool Tip & Flexible Tubingat Least 30 Cm Long Terminating Into A 1 / 4 Connector- Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 10F ( 3.3 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 13F ( 4.3 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 15F ( 5 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type2 ) Silicone Tip With Malleable Introducer 16F ( 5.3 Mm ) - Spr , Left Heartvent Catheter ( Type2 ) Silicone Tip With Malleable Introducer 20F ( 6.7 Mm ) - Spr , Left Atrial Pressure Monitoring Catheter - 3F ( 1Mm ) = 20 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Left Atrial Pressure Monitoring Catheter - 4F ( 1.43Mm ) = 17 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Left Atrial Pressure Monitoring Catheter - 5F ( 1.7Mm ) = 15 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Disposable Yankur Suction Cannula With Transparentconnecting Tube Of At Least 1 Meter Long , Red Rubber Latex Catheters - 8F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Red Rubber Latex Catheters - 8F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Red Rubber Latex Catheters - 10F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Red Rubber Latex Catheters - 12Ffor Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Red Rubber Latex Catheters - 14F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Red Rubber Latex Catheters - 16F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16 Longoveral.-Spr , Vascular Tourniquet ( Snugger ) Set Adult ( 7 Long ) For Open Heart Surgery - Color Coded 4 Tubes With One Snare- For Snugging The Purse String Sutures During Open Heart Procedures - Spr , Vascular Tourniquet ( Snugger ) Set Pediatric ( 6 Long ) For Open Heart Surgery - Color Coded 4 Tubes With One Snare- For Snugging The Purse String Sutures During Open Heart Procedures - Spr , Silicone Vessel ( Vascular ) Loop - Large Size Sterile Medical Grade Radioopaque Silicone Loop 2 To 2.5 Mm Wide , < 1.2 Mm Thick & At Least 40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Silicone Vessel ( Vascular ) Loop - Small Size Sterile Medical Grade Radioopaque Silicone Loop 1 To 1.3 Mm Wide, < 1 Mm Thick & At Least 40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Silicone Vessel ( Vascular ) Loop - Tinysize Sterile Medical Grade Radioopaque Silicone Loop 0.5 Mm Wide, < 0.4 Mm Thick & At Least40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Air-Cushioned- Silicone Vessel ( Vascular ) Loopwith Needle -Medical Grade Siliconeloop With Hollow Interior For The Air-Cushion Effect - With The Maximumdiameter Of The Loop Less Than1.3 Mm ( Thickness ) Andat Least25 Cm Long- Spr , Temporaryepi-Myocardialpacing Wire - Adult Type - At Least 60 Cm Long For Intraoperative Placement During Cardiac Surgery- Incorporating Astraight Cutting Needle Of At Least 60 Mm Longwith ‘Breakaway’ Feature Enabling The Remaining Butt To Be Used As A Connecting Plug To The Pace Maker. The Other End Of The Wire Should Have 25 To 27 Mm Tapercut 1 / 2 Circle Needle -Spr , Temporary Epi-Myocardial Pacing Wire - Pediatric Type - At Least 60 Cm Long For Intraoperative Placement During Cardiac Surgery- Incorporating Astraight Cutting Needle Of At Least 60 Mm Longwith ‘Breakaway’ Feature Enabling The Remaining Butt To Be Used As A Connecting Plug To The Pace Maker. The Other End Of The Wire Should Have 16 To 18 Mm Tapercut 1 / 2 Circle Needle -Spr , Sternalclosure Polymer Bands Sterile Bands ( Of Less Than 5 Mm Width ) Made Of Biocompatible & Mri Compatible Poly-Ether-Ether-Ketone Polymer Substance In A Pack Of 5 Bands - These Bands Must Be Amenablefor Being Cut Open With Standardwire Cutters In Case Of Sternal Re-Entry Procedures. , Coronaryshunts ( Silicon Type ) 1 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.25 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.5 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.75 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 2 Mm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Disposable Aortic -Vascular Punch 2.5 To 2.8 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 3 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 3.5 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 4 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Angled Disposable Bull Dog Type Vascular Clamp-Type Awith Clamping Pressure Of 10-15Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Bwith Clamping Pressure Of 20-25Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Cwith Clamping Pressure Of 75-80Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Dwith Clamping Pressure Of 165-175Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Suction Based Cardiac Stabilizer -Retracting Arm Unit Type ( Octopus Like ) For Opcab ( Off Pump Coronary Artery Bypass ) .The Retracting Arms Unit Should Have Surgeon Controlled Pod-Spread, Allowance For Multiple Device Positions Including Pods-Up, Pods-Down And Pods-To-The-Side Applications, One-Handed Engagement Of Clamp And Turret Assembly. , Suction Based Cardiac Stabilizer - Apex Positioner ( Starfish Like ) For Opcab ( Off Pump Coronary Artery Bypass ) .Should Enhance Lifting The Apex Of The Heart And Fixing To Any Positon. , Mist Blowing Device For Opcab ( Off Pump Coronary Artery Bypass ) . With Fluid / Gas Mixing Technology Creating A Consistent, Predictable Blood Clearing Mist. On / Off Control In Hand-Piece - Malleable Shaft - Specialized Nozzle, Utilizing A Micro-Orifice For Fluid Delivery And A Separate Orifice For Gas Delivery- Spr , Vessel Cannula - 3 Mm Tip -With Stepped Contour - Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. , Vessel Cannula - 2 Mm Tip -With Stepped Contour - Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. , Ima ( Internal Mammary Arterial ) Cannula -1Mm - With Bulb Shaped Tip For Checking Patency Of The Artery , Arteriotomy Cannula -2 Mm With Polyurethane Tube With A Bulb Shaped Tip Connected To A Winged Female Luerabout 5 Cmlong - Spr , Custom Madeelastic Stockings For Lower Limbs With Suitableapplier- Made Up Of A Mix Of Cotton, Polyamide & Elastane. ( Quote Only The Price Of A Single Stocking Not Of A Pair ) For Patients After Venous Harvest Or With Varicose Veins - Spr , Valves General Instructions The Valves Have To Be Supplied On Consignment Basis Such That- A Stock Of One Valve In Each Size Should Be Made Available In The User Area ( Ctvs-Ot ) And After The Utilization Of A Valve Of Particular Size, The Same Has To Be Replaced To Fill The Stock By The Firm Who Supplied The Valve. The Infromation Ofutilization Of The Valve Has Tobe Conveyed To The Supplier By The Storekeeper Who Inturn Will Be Informed By The Sno Of Ctvs Ot. , Tilting Disc Aortic Valve 18 / 19 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 20 / 21 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 22 / 23 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 24 / 25 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 25 / 26 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 27 / 28 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 29 / 30 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 31 / 32 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Bileafletaorticvalve 16 / 17 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 18 / 19 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 20 / 21 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 22 / 23 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 24 / 25 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 26 / 27 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileaflet Mitralvalve 16 / 17 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 18 / 19 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitral Valve 20 / 21 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitral Valve 22 / 23 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 24 / 25 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 26 / 27 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 28 / 29 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 30 / 31 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bovinepericardial Stented Bioprosthetic Aortic Valve19 / 20Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 21 / 22 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 23 / 24 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base. With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base. With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve29 / 30Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve 27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve29 / 30 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve31 / 32 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve 33 / 34 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 19 / 20Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 21 / 22 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcinestented Bioprosthetic Aortic Valve 23 / 24 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcinestented Bioprosthetic Aortic Valve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve29 / 30Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve29 / 30 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve31 / 32 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve33 / 34 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 19 / 20 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 21 / 22 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 23 / 24 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 25 / 26 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 27 / 28 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 29 / 30 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 12 / 13 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 14 / 15 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit. Valve Size : 16 / 17 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit. Valve Size : 18 / 19 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 20 / 21 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Prostheticcomposite Aortic Valved Conduitswith Valve Size 18 / 19 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 20 / 21 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 22 / 23 Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 24 / 25Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 26 / 27 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 28 / 29 Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Ophthalmic Cautery- Sterile , Disposable & Battery Operated For Making Perfect Holes In The Prosthetic Vascular Grafts , Annuloplasty Complete Ring For Mitral Valve. Size : 23 / 24 Mm Near Anatomical Contour Withasymmetric Remodelling Design. Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 25 / 26 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 27 / 28 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 29 / 30 Mm Near Anatomical Contour Withasymmetric Remodelling Design. Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 31 / 32 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 33 / 34 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 35 / 36 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:25 / 26 Mm. Near Anatomical Contour With Downward Angle At Septal End. Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:27 / 28 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being: 29 / 30 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being:31 / 32Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being: 33 / 34 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:35 / 36 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being: 37 / 38 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:39 / 40 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Suture Guide / Suture-Grip / Suture-Organizer Of Gabbay Fratermechanism For Heartvlave Operationscurved Profile With Capacity To Hold At Least 8 Paired Sutureswith Positional Numbering Labelled In A Guide With Fixation Ports. Each Sterile Pack Should Contain3 Such Guides. , Arterial Embolectomy Caztheter 2F X 60 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 3F X 80 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 5F X 80 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 7F X 80 Cm - Enclosed In A Rigid Case - Spr , Ptfe Vascular Tube Grafts 3 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 3.5 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 4 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 4.5 Mm-At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 5 Mm-At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 6 Mm -At Least 10 Cm Long , Ptfe Vascular Tube Grafts 7 Mm -At Least 10 Cm Long , Ptfe Vascular Tube Grafts 8 Mm-At Least 10 Cm Long , Ptfe Vascular Tube Grafts 6 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 7 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 8 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 12 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 14 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 16 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 18 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 20 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 22 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 24 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 5 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 6 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 7 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 8 Mm-At Least50cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 6 Mm - At Least 70Cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 7 Mm - At Least 70Cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 8 Mm - At Least 70Cm Long , Axillo-Bifemoralptfe Vascular Tube Grafts- 8 Mm Diameter & Length Of 90 Cm Plus50 Cm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. , Cuffed Eptfe Graft With Trim Line Of 4-6 Mmx 60 Cm- For Ananstamosis With The Small Recepient Vessel Of Size -3Mm & Less. Preferably Within-Built Antiplatelet / Antithrombotic Mechanism. , Cuffed Eptfe Graft With Trim Line Of 4-6 Mmx 90 Cm- For Ananstamosis With The Small Recepient Vessel Of Size -3Mm & Less. Preferably Within-Built Antiplatelet / Antithrombotic Mechanism. , Av Accesseptfe Graft-6Mm X 40 Cm Designed Specially Forforcreating Av Fistual Creation For Hemodialysis. The Graft Should Be Able To Withstand Multiple Needle Punctures Without Bleeding After The Needle Is Removed. , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia:20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 32 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 34 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 36 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 32 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 34 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 36 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 16 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 12 Mm X 6 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 14 Mm X 7 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 16 Mm X 8 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 18 Mm X 9 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 20 Mm X 10 Mm , Polyester Fiber Suture / Ligature5 Mm X At Least 40 Cm ( For Pulmonary Arterialbanding ) Spr , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 4-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 5-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 6-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Polybutester Suture With Polytribolate Coating With The Property Of Needle Hole Self-Sealing For Vascular Anastamoses. Size 7-0 X 60 Cm With 3 / 8 Circle8mm Needle ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 5Cmx 10 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 10Cmx 10 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 15Cmx 15 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 6 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 8 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 8 Mm X 152 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 25 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 25 Mm X 152 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 25 Mm X 50 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 25 Mm X 100 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 50 Mm X 50 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 75 Mm X 75 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 100 Mm X 100 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:6 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:10 Mm X 140 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:20Mm X 140Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Typed ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25Mm X 50 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 100 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 150 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 50 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 150 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:75 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:100 Mm X 100 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :25Mmx 152 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :51Mmx 76 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :51Mmx 152 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 6 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 6 Mm X 122 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 8 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 8 Mm X 152 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 25 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 25 Mm X 152 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 50 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 60 Mm X 30 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 70 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 80 Mm X 40 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 100 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 120 Mm X 40 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 120 Mm X 80 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 25 Mm X 50 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 25 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 50 Mm X 50 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 50 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick -100 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Pet ( Polyethylene Pteriphthalate ) Patch About8 Mm X 75 Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About25 Mm X 76 Mm - Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 25 Mm X 152Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 50 Mm X 76 Mm - Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 50 Mm X 152 Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 20 Mm X 30 Mm Made Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 20 Mm X 75 Mm Made Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 15 Mm X 20 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 8 Mm X 30 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -6 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -8 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -10 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -20 Mm X 90Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) -8Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) -10 Mm X 90 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 25Mm X 150Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 30Mm X 30Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 30Mm X 60Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 50Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 10 Mm X 90 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 20 Mm X 90 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 30 Mm X 60 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 30 Mm X 30 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 50 Mm X 75 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 25 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 50 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 100 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 50 Mm X100 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 100 Mm X100 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 150 Mm X150 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Felt1.65 Mm Thick -150Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felts- 1.65 Mm Thick 12 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick25 Mm X 25 Mm , Ptfe Felts- 1.65 Mm Thick25 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick 25 Mm X 150 Mm , Ptfe Felts- 1.65 Mm Thick 50 Mm X 50 Mm , Ptfe Felts- 1.65 Mm Thick100 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick150 Mm X 150 Mm , Ptfe Felt With Low Porosity - 1.85 Mm Thick - 25 Mm X 25 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felt With Low Porosity -1.85 Mm Thick - 100 Mmx 100 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felt With Low Porosity -1.85 Mm Thick - 150Mm X150 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Tissue Engineered Pericardial Patch4 Cm X 4Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch6 Cm X 6 Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch8 Cm X 8Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch10cm X 10 Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Ptfepledgets Thickness X Breadth & Length : 0.5Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgets Thickness X Breadth & Length : 1 Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgetsthickness X Breadth & Length :1 Mm X 3 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgets Thickness X Breadth & Length : 1.5Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgetsthickness X Breadth & Length : 1.5Mm X 3 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfe Feltpledgetsthickness X Breadth & Length : 1.65 Mm X 4.8Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfefelt Pledgets Thickness X Breadth & Length :1.65 Mm X 6 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Topical Hemostatic : Fibrinogen- Human Thrombin- Aprotinin -In Prefilled Syringes Applicatorwith Atotal Volume Of10 Ml In A Pack. Spr , Topical Hemostatic : Polythylene Glycol - 4 Mlfor Raw Surfaces Oflung For Hemostatic And Also For Preventing Air Leak And Alsopreventive Usage Incardiac / Vascularsuture Lines , Topical Hemostatic- Albumin Gluter-Aldehyde Glue -Total Volume Of 10Ml Per Packcontained In The Prefilled Syringes Andforming A Strongbut Flexiblelayer Of Seal- Compatible To Fix The Separated Layers Of Dissected Aorta. To Be Provided With Suitable Applicator For Focused Local Application. , Topical Bio-Absorbable Hemostatic: Non-Oxidativecellulose 5 X 5 Cm - Hemostatic Acting By Non--Oxidative Chemical Reaction Using Cellulose Asa Substance. , Trachealstents ( Fully Covered ) - Straight Type. Should Have Radioopaque Markers At Both The Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Trachealstents ( Fully Covered ) - Bifurcated Y Typeshould Have Radioopaque Markers At All The Three Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Bronchial Stents ( Fully Covered ) - Straight Type. Should Have Radioopaque Markers At Both The Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Guidewire For Deployingthe Tracheal Stent - The Selection Will Be Based On The Compatibility Wit The Brand Selected For The Tracheal Stent . , Thoracic Aortic Stent Grafts - Straight Type :To Be Supplied With The Suitable Delivery System With Smallest Possible Catheter Outer Diameter.The Stent Should Be Mri Compatible. The Purchase Will Be Done As When Needed, In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Surgery And After The Usage The Rest Of Thestents Can Be Taken Back - I.E Consignment Mode. The Various Available Sizes And Length May Be Mentioned While Quoting. ( Size Ordered Will Be Based On The Patients Condition ) , Thoracic Aortic Stent Grafts - Bifurcated Y Type :To Be Supplied With The Suitable Delivery System With Smallest Possible Catheter Outer Diameter.The Stent Should Be Mri Compatible. The Purchase Will Be Done As When Needed, In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Surgery And After The Usage The Rest Of Thestents Can Be Taken Back - I.E Consignment Mode. The Various Available Sizes And Length May Be Mentioned While Quoting. ( Size Ordered Will Be Based On The Patients Condition ) , Sterile Guidewire Suitable To Fit 16G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 18G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 20G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 22G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire - 0.038 Inchfor Femoral Vessel Cannulation , Femoral Puncture Needle - 16G - For Seldinger Technique - At Least 180 -200 Cm Long.Spr. , Cabg Drape Kit With9 Components: ( Totally15+1Parts In A Pack ) Go Through The Link For Detailed Specifications: Https: / / Docs.Google.Com / Document / D / 1Yoteirccpx3apbvgbx438oyfictzx77splq3xk4zapa / Edit , General Open Heart Drape Kit Containing The Following Components. ( Totally10+1Parts In A Pack ) Go Through The Link For Detailed Specifications:Https: / / Docs.Google.Com / Document / D / 1_H3eesdoj0ticagchls5bvnmxgqff3lw9ptypavhcke / Edit?Usp=Sharing , Sternalwound Dressing Pad - Sterileadhesive Polyurethane Film With Absorbent Pad, 20 X 10 Cm - Spr , Montogomer T-Type Silicon Tracheostomy Tube - Spr , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-26Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-28Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-32Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-35Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-37Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-39Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-41Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-26Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-28Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-32Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-35Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) -Rightsided-37Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Rightsided-39Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) -Rightsided-41Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Endo-Bronchial Blockers - Withballoon - Ardnt Type - For One Lung Ventilation - Wire Loopguide And Suitable Adapterforbronchoscope. , Endo-Bronchial Blockers - Withballoon -Cohentype - For One Lung Ventilationwith Flexible Defelcting Tip With Suitable Adapter To Faciltate Bronchoscope. , Endo-Bronchial Blockers - Withballoons -Eztype - With Y-Tipped For One Lung Ventilation , Ultrasonic Nebulizer -Spr Fordemostration. Or Product Catalogue Brochure With Figure To Be Submitted. , Soft Vinyl Percussors For Performing Chest Physiotherapy Indifferent Sizes , Electro Surgical ( Cautery ) Pencils - ( Electrosurgical Electrode ) With Long Arm- Spatula Tip &Hand Control Oftwin Switch Type For Cutting And Coagulation Modes-Should Be Compatible With Martin & Alancautery ( Electrosurgical ) Machines. Prefererable Dimensions:Shaft Diameter Less Than 2.5 Mm. Shaft Length -130-140 Mm Spatula Dimension - About 20 X 2.5 X 0.5 Mm Appropraite Certification For Electrical Safety Should Be Confirmed. - Spr , Disposable Microscalpel Withhigh Qualitymicro-Blade Attached For Coronary Arteriotomy - Spr , Sterile Cover For Echocardio-Graphicprobefor Use In The Operative -Field. Should Fit Universally All Utrasound Probes Commonly Used During Cardiac Surgery With Special Fold To Accomdatethe Probe End Without Wrinkles. Should Be Made Up Of Clear Transparent Latex Free Medical Grade Material - Polythene.Length Of Cover - 150 Cm;Width Of The Cover - 10 Cm. The Kit Should Also Contain Securing Tapes To Hold The Cover Around The Probe And Preferably With Ultrasound Transmission Gel - Pack. , Non-Consumables , De Bakeystraightfinevascularforceps - Short ( 18Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakey Straightfinevascularforceps - Medium ( 25Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakeystraightfinevascularforceps - Long ( 30Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakey Angled 45º Finevascular Fine Forceps - Short ( 18Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakey Angled 45º Finevascular Forceps - - Medium ( 25 Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakeyangled 45ºfine Forceps Vascular - Long ( 30 Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakeydouble Actionstraightfinevascularforceps - Short ( 18Cm ) - With 1X2 Teeth - Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightfinevascularforceps - Medium ( 25Cm ) - With 1X2 Teeth -Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightfinevascularforceps - Long ( 30Cm ) - With 1X2 Teeth - Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightvascularforceps - Short ( 18Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraightvascularforceps - Medium ( 25Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraight Vascularforceps - Long ( 30Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraighttissueforceps - Short ( 18Cm ) With 1X2 Teeth- Jaw ( 3 X 14 Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraighttissue Forceps - Medium ( 25Cm ) With 1X2 Teeth- Jaw ( 3 X14mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraight Tissueforceps - Long ( 30Cm ) With 1X2 Teeth- Jaw ( 3 X 14 Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Short ( 18Cm ) With3 X2 Teeth - Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Medium ( 25 Cm ) With3 X2 Teeth- Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Long ( 30Cm ) With3 X2 Teeth - Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , Resano Atruamatic Forceps - Short ( 18 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Forceps - Medium ( 25 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm & 4-6 Mm Wide Shaft. , Resano Atruamatic Forceps - Long ( 30 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Forceps-Short ( 18 Cm ) - Straight Jaws-14 Mm & 4-6 Mm Wide Shaft. , Resano Atruamaticdouble Action Forceps-Medium ( 25 Cm ) -Straight Jaws-14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Forceps-Long ( 30 Cm ) - Straight Jaws14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Largeforceps-Short ( 18 Cm ) -Straight Jaws-18 Mm & 4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Large Forceps-Medium ( 25 Cm ) -Straight Jaws18 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Large Forceps-Long ( 30 Cm ) -Straight Jaws-18 Mm & 4-6 Mm Wide Shaft. , Gemini Double Action Diliating, Curved, Smooth Forceps ( 31-37 Cmlong ) With 1 X 2 Teeth, Jaw Length - 30 Mm, Shaft Dia 4-6 Mm , Rongeur For Valve - 30º Curved Tip ( 31-37 Cm Long ) Jaw Size - 3.5 Mmshaft Dia: 4-6 Mm , Rongeur For Valve - Straighttip ( 31-37 Cm Long ) Jaw Size - 3.5 Mm Shaft Dia : 4-6 Mm , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 120 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 90 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 60 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp -Slim - 30 - 36 Cm Jaw Size - 120 Mm- ( 1 X 2 Teeth ) , Debakey -Chitwood Aortic Cross Clamp -Slim30 - 36 Cm Jaw Size - 90 Mm- ( 1 X 2 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - Slim 30 - 36 Cm Jaw Size - 60 Mm- ( 1 X 2 Teeth ) , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type18 Inches Longwith Straight Jaw ( 30-35 Mm ) With Insert. , Spareinserts ( 30-35 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No.Nc37 Mention The Cost Of A Pair Of The Insert , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type- 18 Inches Longwith Straight Jaw ( 60-65 Mm ) With Inserts. , Spareinserts ( 60-65 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No. Nc39mention The Cost Of A Pair Of The Insert , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type18 Inches Longwith Straight Jaw ( 85-90 Mm ) With Inserts. , Spareinserts ( 85-90 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No. Nc41 Mention The Cost Of A Pair Of The Insert , Nerve Or Vessel Hook - Ball Tiptotal Length : 32-37 Cmwith Working Length -23 Cm Tip Length :10 Mm , Nerve Or Vessel Hook- Fine Tip Total Length : 32-37 Cmwith Working Length -23 Cm Tip Size :1 X 6Mm , Nerve Or Vessel Hook Standard Tip Total Length : 32-37 Cmwith Working Length -23 Cm Jaw Size:2 X 10Mm , Nerve Or Vessel Hook - 90ºwith Fine Tip. Total Length : 32-37 Cmwith Working Length -24-28 Cm Jaw Length :4-7 Mm , Jacobsonmicroscissors 25º -Round Handle -16 To 20 Cm , Jacobsonmicroscissors 45º -Round Handle -16 To 20 Cm , Jacobsonmicroscissors 60º - Round Handle -16 To 20 Cm , Jacobsonmicroscissors 90º - Round Handle -16 To 20 Cm , Jacobsonmicroscissors 125º -Round Handle -16 To 20 Cm , Potts / Potts Smith / Diethrich-Potts Scissors 25º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 45º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 60º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 90º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 125º- ( 16 To 20 Cm ) , Iris Scissors - Ring Handle With Fine Straight Tips -10 To 12 Cm , Iris Scissors - Roundhandle With Fine Straight Tips -10 To 12 Cm , Debakeyscissors 25º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 45º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 60º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 90º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 125º - ( 16 To 20 Cm ) - Ring Handle , Favaloro Vascular Scissors 125º - ( 16 To 20 Cm ) - Ring Handle , Metzenbaum Scissors ( Standard ) 16-20 Cm - Curved Blades - Ring Handle , Metzenbaum Scissors ( Long ) 20-25 Cm - Curved Blades - Ring Handle , Metzenbaum Scissors ( Extra-Long ) 30-32 Cm - Curved Blades - Ring Handle , Mayo Scissors - Straight Round - Standard - 17-20 Cm , Mayo Scissors - Curved Round - Standard - 19-23 Cm , Mayo-Harrington Scissors - Straight- 30-32 Cm , Wire Cutter - Double Action -Tungsten Carbide Edge 17-20 Cm , Rib Shears ( Gluck Type ) - 18-20 Cm , Rib Shears ( Bethune ) - 32-36 Cm , Yankauer Suction Tube- 28-35 Cm , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.10 , Standard Scalpel Handle -Short12-14 Cmfor Blade No.11 , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.15 , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.23 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.10 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.11 , Standard Scalpel Handle -Long 21-23 Cmfor Blade No.15 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.23 , Jacobson Needle Holder - Long ( 24-25 Cm ) For 2-0, 3-0 & 4-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Short ( 18-20 Cm ) For 2-0, 3-0 & 4-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Long ( 22-24 Cm ) For 5-0& 6-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Short ( 18-20 Cm ) For 5-0 & 6-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Micro-Needle Holder - Long ( 22-24 Cm ) For7-0 & 8-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Micro-Needle Holder - Short ( 18-20 Cm ) For7-0 & 8-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Richards Micro Needle Holder -18-20 Cm For 6-0, 7-0 &8-0 Sutures Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Ryders Needle Holder 18-20 Cmfor 5-0 Sutures With- Diamond Coated Tip With Straight Jaws &Ring Handlewith Ratchet , Debakey Needle Holder 24-25 Cmfor 5-0 Sutures With- Diamond Coated Tip With Straight Jaws &Ring Handlewith Ratchet , Debakey Needle Holder 15-16 Cmfor 2-0, 3-0 & 4-0Sutures With- Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Debakey Needle Holder 20-22 Cmfor 2-0, 3-0 & 4-0Sutures With- Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 23-25 Cm With Tungsten Cardbide Edgesring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 20-21 Cm With Tungsten Cardbide Edges Ring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 18-19 Cm With Tungsten Cardbide Edges -Ring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 14-15 Cm With Tungsten Cardbide Edges -Ring Handle, - With Ratchet , Titaniumdennis Micro-Forceps ( Straight ) - 1 Mm Ring Tip - 18-20 Cm Counter - Balancedround Handle With Diamond Coating - , Titaniumdennis Micro-Forceps ( Straight ) -Pointed Platform Tip -18-20 Cm- Counter-Balancedround Handle With Diamond Coating - , Titaniumdennis Micro-Forcepsstraight Standard 1Mm Tip 18-20 Cm Round Handle With Diamond Coating , Titaniumgeraldmicro-Forcepsstraightring Tip 1Mm-18-20 Cm - Round Handle& Diamond Coating , Titaniumgeraldmicro-Forcepsstraight Platform Tip 1Mm 18-20 Cm - Flathandle& Diamond Coating , Titaniumgeraldmicro-Forcepsstraight Tip 1Mm 18-20 Cm - Withflat Handle , Titaniumdebakey Dissection -Forceps -Straight Tip 1Mm 18-20 Cm -Flat Handle , Titaniumdebakey Dissection -Forceps -Straight Tip 2 Mm 18-20 Cm -Flat Handle , Hegar Heavy Needly Holder - 20 Cm With Tungsten Carbide Edges - Jaw Width Tapering From5 Mm To 3 Mm With Jaw Length About 20 Mm , Heavy& Long Needle Holder -27 Cm With Tungsten Carbide Edges - Jaw Width Tapering From5 Mm To 3 Mm With Jaw Length About 20 Mm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Sep-2021 Date Corriendum Date 18-09-2021
2 18-Sep-2021 Date Ext Date 25-09-2021

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail