Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - B

Tender Notice

28774282
Corrigendum : Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - B
Indian
Puducherry
18-09-2021
25-09-2021
27-09-2021

Tender Details

Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Ctvs For 2021 22 , Perfusion Technological Consumables-Abbreviations Used Msa - Membrane Surfacearea, Bfr - Blood Flow Rate Spv - Static Priming Volume, Cvr - Cardiotomy Venous Reservoir. Pv - Priming Volume, Bhpsc - Biocompatible Hydrophilic Polymer Surface Coating, He - Heat Exchanger.Ss - Stainless Steel Spr - Sample To Be Provided , Membrane Oxygenator-Large Adult- Type A Msa = 1.7 To1.8M², Max. Bfr = 8L / Min, Spv= 220Ml, Cvr = 4500Ml, Surface Must Be Coated, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Large Adult- Type B Msa = 1.4 To 1.8M², Max Bfr =6 L / Min, Spv = 185Ml, Cvr = 4500Mlcoated Surface -Polyurethane He, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Large Adult- Type C Msa = 1.4 To1.8M², Max Bfr = 6 L / Min, Spv = 185Ml, Cvr = 4500Ml, Integrated Arterial Filter, Surface Must Be Coated, Polyurethane He, Primary Pack Should Be Labelled.Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Small Adult- Type A Msa=1.3 To 1.5 M², Max Bfr= 5 L / Min, Spv = 175Ml, Cvr = 4000Ml. Biocompatible Surface Coating Preferable. Stainles Steel He, Primary Pack Should Be Labelled.Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Smalladult- Type B Msa = 1.3 To1.5 M², Max Bfr =5L / Min, Spv =295Ml, Cvr = 4000Ml. Integrated Arterial Filter, Ss-He, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Small Adult- Type C Msa= 1.5M², Max Bfr= 4 L / Min, Spv = 135 Ml, Hard Shell Reservoir Capacity 3000-3200Ml, Metal He.Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied.Spr , Membrane Oxygenator- Pediatric- Type A Msa = 1.1M², Max. Bfr 2.8 To3.5L / Min, Spv = 130Ml, Cvr = 2500Ml, Ss- He Integrated With Oxygenator. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator - Pediatric- Type B Msa = 0.8M², Max Bfr 2.1 -2.8 L / Min, Spv= 100Ml, Cvr = 1500Ml, Ss-He Integrated With Oxygenator. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator-Pediatric- Type C Msa = 0.67M², Max Bfr = 2 L / Min, Spv = 48Ml. Integrated He Of Terephthalate ( Pet ) Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Infant Msa = 0.5M², Max Bfr = 1.5 L / Min, Spv = 43Ml, Integrated Ss-He. Biocompatible Hydrophilic Polymer Surface Coating .Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Neonate Msa = 0.35M², Max Bfr= 1 L / Min, Spv = 38Ml, Integratedss-He , Coated Surface. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Membrane Oxygenator- Dual Chambercvr Integrated With Arterial Filter Msa = 1.6 To 1.85M², Max Bfr -7 L / Min, Spv = 350Ml, Coated Surface, Two-Step Lipid-Leukocytes Depletion Cvr, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator -Adultmsa =1.8M², Max Bfr= 7 L / Min, Spv = 250 Ml. Cvr=4 Lit, Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator - Small Adult Msa =1.2M², Max Bfr= 5L / Min, Spv = 150 Ml. Cvr=3 Lit Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator-Pediatric Msa = 0.67M², Max Bfr Up To 4L / Min, Spv = 90 Ml. Cvr=2.5 Lit Diffusion Membrane Material Polymethyl Penteneprimary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator -Neonate Msa = 0.69M², Max Bfr=1.5 L / Min, Spv = 95Ml.Cvr = 1.5 Lit. Diffusion Membrane Material Polymethyl Pentene. Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Adulttype 1Msa =1.8M², Max Bfr= 7L / Min , Spv = 250 Ml, Rf-32 Or Flo Pump32centrifugal Pump Head, Diiffusion Membrane Ofpolymethylpentene.Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Adulttype 2 Msa = 1.8M², Max Bfr= 7 L / Min, Spv=250 Ml, Vaned Impeller Design Ofpump Head- Diffusion Membrane Material Polymethylpentene, - 3 / 8 Inch Inlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) & Sorin S5 ( Cp5 ) , Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Smalladulttype 1 Msa = 1.5M², Max Bfr= 5L / Min , Spv = 200 Ml, Rf-32 Or Flo Pump32 Centrifugal Pump Head, Diffusion Membrane Material Polymethylpentene , Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use - Smalladulttype 2 Msa = 1.5M², Max Bfr= 5L / Min, Spv = 200 Ml, Vaned Impeller Design Pump Head, Diffusion Membrane Material Polymethylpentene , 3 / 8 Inchinlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) & Sorin S5 ( Cp5 ) Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Pediatric Type 1Msa =0.69M², Max Bfr = 1.5.L / Min, Spv =90 Ml. Rf-32 Or Flopump32centrifugal Pump Head, Polymethylpentene Membrane, Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Ecmo Oxygenator With Circuit Formultipurpose Use -Pediatric Type 2 Msa = 0.69M², Max Bfr= 1.5L / Min, Spv =90 Ml. Vaned Impeller Design Pump Head, Polymethylpentene Membrane, 3 / 8 Or 1 / 4 Inchinlet & Outlet With Housing To Fit The Centrifugal Console Of Aps-I ( Terumo ) &Sorins5 ( Cp5 ) . Primary Pack Should Be Labelled. Holder & Temperature Probe To Be Supplied. Spr , Hemofilter- Big Adult Msa = 1.4M², Pv = 80 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled.Spr , Hemofilter- Adult Msa = 1.1M², Pv=71 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter- Small Adult Msa = 0.71M², Pv = 65 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter -Pediatric Msa=0.3M², Pv= 35 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Hemofilter-Infant Msa =0.1M², Pv= 20 Ml, To Be Supplied With Tubing Set & Collection Bag & A Suitable Holderprimary Pack Should Be Labelled. Spr , Arterial Filter - Adult Max Bfr=7 L / Min, Spv = 125 Ml, Pore Size-37Μm, Blood Port= 3 / 8 Inchbypass Loop& 3-Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Arterial Filter - Small Adult Max Bfr=4L / Min, Spv = 80 Ml, Pore Size-37Μm, Blood Port= 3 / 8 Inchbypass Loop & 3-Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Arterial Filter - Pediatric Max Bfr=2.5 L / Min, Spv = 40 Ml, Pore Size-32Μm, Blood Port=1 / 4 Inch. Bypass Loop & 3Way With One-Way Valve Purge Line & A Suitable Holder - To Be Supplied.Primary Pack Should Be Labelled. Spr , Custom Pack-Adult- Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Small Adult -Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Pediatrictubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Custom Pack-Neonatal Tubing Setfor Cpb As Per Jipmer 2020 Circuit. ( Contact Ctvs Dept For Figures ) , Ecmo Adult Tubing Set Custom Pack As Per The Jipmer2020 Circuit. Primary Pack Should Be Labelled. Spr . ( Contact Ctvs Dept For Figures ) , Ecmo Pediatric Tubing Set Custom Pack As Per The Jipmer2020 Circuit. Primary Pack Should Be Labelled. Spr . ( Contact Ctvs Dept For Figures ) , Cardio Plegia Delivery System ( Cpds ) - Reservoir Typeminimum 2-L Reservoir Capacity With At Least 4 X 1 / 4” Ports With Holder Primary Pack Should Be Labelled. . Spr , Cardio Plegia Delivery System ( Cpds ) -4:1 Type Pv= 30Ml, Max Bfr = 2.5 L / Min With 3-Way With Purge Line.Preferably Withgroved Stainless Steel He & 150 Μm Polyester Screen Filter.Primary Pack Should Be Labelled. Holder To Be Supplied. Spr , Centrifugal Pump Head -Adult Type 1 Vaned Impeller Design, 3 / 8 "Inlet & Outlet With Housingto Fit The Centrifugal Console Of Heart Lung Machine Of Aps-I ( Terumo – Sarns ) & Sorin S5 ( Cp5 ) .Spr , Centrifugal Pump Head - Adult Type 2Priming Volume = 32Ml, 3 / 8 Inch Inlet & Outlet With Housingto Fit The Centrifugal Console Of Rotaflow ( Maquet ) . The Pump Head Should Bewithout A Metal Shaft Or Seal.Spr , Centrifugal Pump Head - Pediatrictype 1 Vaned Impeller Design, 1 / 4" Inlet & Outlet With Housing To Fit The Centrifugal Console Of Heart Lung Machine Of Aps-I ( Terumo–Sarns ) & Sorin S5 ( Cp5 ) . Spr , Centrifugal Pump Head - Pediatrictype 2 1 / 4" Inlet & Outlet With Housing To Fit The Centrifugal Console Of Rotaflow ( Maquet ) . The Pump Head Should Bewithout A Metal Shaft Or Seal. Spr , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) -30 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) 34 / 35 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) - 40 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Intra Aortic Balloon ( Compatible With Arrowiabp Machine ) - 50 Cc To Be Supplied With Suitable Conectors And The Kit For Femoral Insertion Of The Balloon. , Pressure Transducers -Single Type Forheart Lung Machine Sarns Heart Lung Machine And Aps-Iwith 200 Cm Pressure Line& A Pressure Cable Suitable For The Device And The Machine Has To Be Supplied Free Of Cost With Every100 Transducers Purchased-Spr , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size A -3 / 16" X 3 / 16". , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size B - 1 / 4" X1 / 4".. , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size C -3 / 8" X 3 / 8". , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size D -1 / 4" X 3 / 8". , Straight Connectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size E -3 / 8" X 1 / 2". , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size A-3 / 16" X 3 / 16" X 3 / 16" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size B-3 / 16" X1 / 4" X 1 / 4" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size C-1 / 4" X1 / 4" X 1 / 4" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size D-1 / 4" X1 / 4" X 3 / 8" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size E-3 / 8" X 3 / 8" X 3 / 8" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size F-3 / 8" X 3 / 8" X 1 / 4" , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size G-1 / 2X 3 / 8X 3 / 8 , Yconnectors With Female Luer Lock - Disposable, Sterile, Transparent - Made Up Of High Quality Plasticsuitable For Cardio- Pulmonary Bypass Circuit With Female Luer Lock. Spr Size H-3 / 16" X 1 / 4" X 3 / 8" , Htk Type - Single Shot Cardioplegiahistidine – Tryptophan – Ketoglutarate ( Htk ) Type.Cardioplegic Solution For Myocardial Protection For At Least 3 Hours After A Single Shot Of Cardioplegia.1 Litre , Htk Type - Single Shot Cardioplegiahistidine – Tryptophan – Ketoglutarate ( Htk ) Type.Cardioplegic Solution For Myocardial Protection For At Least 3 Hours After A Single Shot Of Cardioplegia.0.5Litre , Multiple Perfusion Adapter Setwith 4 Legs ( 3 Long +1Short Leg ) With Individual Tubing Clamps For Simultaneous Perfusion Of Venous Grafts And Aortic Root - With Femaleluer Inlet & Maleluer Outlets Preferably Withlength Of- At Least 10" ( Refer Fig. ) Spr. , Minimally Invasive Vascular Access Kitfor Femoral Arterial Cannulation For Cpb Orecmowithscalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F& 16 F / 18 F, Guidewire - 0.038" ( 0.965-Mm ) -100 Cm Long -Forcannulation - Spr , Minimally Invasive Vascular Access Kitfor Femoral Venous Cannulation For Cpborecmo With Scalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F And16 F / 18 F, Guidewire - 0.038" ( 0.965-Mm ) -180 Cm Long- Spr , Minimally Invasive Vascular Access Kitfor Jugular Venous Cannulation For Cpb Orecmo With Scalpel ( #11 ) , Seldinger Needle ( 18G ) Stepped Vessel Dilator- 8 F / 10 F, 12 F / 14 F Guidewire - 0.025" ( 0.535-Mm ) -60 Cm Long-Forcannulation Spr , Dual Lumen Catheter13 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter16 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter19 F For Venovenous Ecmo With Insertionkit Having100 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter20 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter23 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter27 F For Venovenous Ecmo With Insertionkit Having210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Dual Lumen Catheter31 F For Venovenous Ecmo With Insertionkit Having 210 Cm Guidewire , Suitable Seldindinger Puncture Needle.Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 8Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 10Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 12Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 14Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 16Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 18Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 20Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 22Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula Plaintype With Straighttip 24Foverall Length Of At Least7 Incheswith Transparent Body Withtapering Contour, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 20F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 22F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Aortic / Arterialperfusion Cannula -Angled ( 45 Deg ) Wirewound - Size 24F - Overall At Least12 Incheswithtransparent & Wirewoundbody, Angled ( 45 Deg ) Bevelled Tip With Side Holes, Tip Orientationline And Tip Guardpreferably With Vented Type Connector - Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 6F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 8F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 10F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 12F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 14F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Pediatricsize 16F - With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 18F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar - Overal Length Of At Least 12 Inch Long Preferably With Guidewire. Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 20F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 22F - With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Elongated Aortic / Arterialperfusion Cannula- Adult Size 24F- With Thin Walledvented Type Tip, Introducer&Depth Markings, Radioopaque Adjustable Suture Collar -Overal Length Of At Least 12 Inch Long Preferably With Guidewire.Spr , Venous Return Cannula - Single Stage -- Straight12fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight14fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight16fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight18fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight20fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight22fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight24fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight26fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight28fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight30fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight32fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight34fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight36fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Straight38fmultiport Tapered Tipwithkink Resistant Wirewoundbody- Over All Length Of At Least12 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 10Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 12Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 14Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 16Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 18Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 20Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 22Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 24Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal26fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula - Single Stage -- Right Angled Metal 28Fmultiporttipwithkink Resistant Wirewoundbody-Tip Orientation Line Over All Length Of At Least14 Inch Long -Spr , Venous Return Cannula-Cuffedsingle Stage - 37F- Wirewound Bodyat Least35 Cm Longwithinflatable Cuff - Spr , Venousreturn Cannula-Two Stageflat Body- 28 / 36F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 29 / 29F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 29 / 37F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 32 / 40F - Thin Walled - Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 36 / 46F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 34 / 46F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Two Stageflat Body- 36 / 51F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Threestage -Oval Body- 29 / 29 / 29 F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Venousreturn Cannula-Threestage -Oval Body- 29 / 46 / 37 F - Thin Walled- Withmulti-Ported Tips& Atrial Basket - Wirewoundwith Depth Markingswith Overall Length Of At Least 38 Cm- Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 8F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 10F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 12F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Pediatric ) - 14F With Depth Marking, Introducer With Central Lumen - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 15F Or 16F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 17F Or 18F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 19F Or 20F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 21F Or 22F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 23F Or 24F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoral Arterialperfusion Cannula ( Adult ) - 25F Or 26F - With Overalllength Of At Least 30 Cmwith Depth Marking, Introducer, Preferably With Central Lumen & Suitable Guidewire ( .038“ ) And Vented Connector - Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 8F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 10F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 12F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Pediatric ) - 14F - With Wire Wound Body, Introducer & Depth Marking & Overalllength Of At Least 19 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -15F-Or 16 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -17F-Or 18 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -19F-Or 20 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -21F-Or 22 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -23F-Or 24 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -25F-Or 26 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -27F-Or 28 F With Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Femoralvenousperfusion Cannula ( Adult ) -29 F Or 30Fwith Multiple Side Holes, Wire Wound Body, Introducer & Depth Markingpreferably With Length Of At Least 50 Cm- Spr , Cardio-Plegic Cannula-Antegrade 3F ( 18G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 4Fwith Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 5F ( 16G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 6F Or 7F ( 14G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 8F Or 9F ( 12G ) With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardio-Plegic Cannula-Antegrade 11F With Introducer Needle, Standard Tip Preferablywith Side Holes- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 4F With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 5F ( 16G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 6F Or 7F ( 14G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 8F Or 9F ( 12G ) With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegic Cannula-Antegrade With Side Limb - 11F With Introducer Needle, Standard Tip Preferablywith Side Holes And A Side Limb For Venting- Spr , Cardioplegiacannula-Minimally Invasive Antegrade Typewithintroducer Needle Withstandard Tip With A Length Of At Least 30 Cm- Spr , Cardioplegiacannula - Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of12f ( 4Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula- Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of15f ( 5Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of18f ( 6Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula -Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of21f ( 7Mm ) & Tip Of 3 Mm-Spr , Cardioplegiacannula -Flexible Left Coronary Ostial Straight Tip Type With Soft Silicone Bulb / Balloon Of24f ( 8Mm ) & Tip Of 3.5 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of12f ( 4Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of15f ( 5Mm ) &Tip Of 2.1 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of18f ( 6Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of21f ( 7Mm ) &Tip Of 3 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Right Angled Type With Soft Silicone Bulb / Balloon Of24f ( 8Mm ) &Tip Of 3.5 Mm-Spr , Cardioplegiacannula - Flexible Coronary Ostial Tapering Typewith Soft Self-Inflating Ballooon- Tip Tapering From 27F ( 9Mm ) To 8F ( 2.7Mm ) And Body Encapsulated With Malleable Wire- Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip -10F ( 3.3Mm ) Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip - 12F ( 4Mm ) Spr , Cardioplegiacannula -Rigid Left Coronary Ostialtype - 45 Deg Angled Basket Tip -14F ( 4.7 Mm ) - Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 Deg Angled Basket Tip -10F ( 3.3Mm ) Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 Deg Angled Basket Tip - 12F ( 4Mm ) Spr , Cardioplegiacannula -Rigid Right Coronary Ostialtype-80-90 Deg Angled Basket Tip -14F ( 4.7 Mm ) - Spr , Retrograde Cardioplegia Cannula ( Coronary Sinus ) Withsolid Stylet 13F -Withauto-Inflatable Cuff& Integral Stop Cock For Pressure Monitoring - Preferably Wirewound Body - Spr , Retrograde Cardioplegia Cannula ( Coronary Sinus ) Withsolid Stylet 15F -Withauto-Inflatable Cuff& Integral Stop Cock For Pressure Monitoring - Preferably Wirewound Body - Spr , Cardiac Suction Tip- ( Mini Sucker ) Soft Flexible Tapered Tip - 9F ( 3Mm ) - With Angled Shaft- Spr , Cardiac Suction Tip- ( Mini Sucker ) Soft Flexible Tapered Tip - 12F ( 3Mm ) - With Angled Shaft- Spr , Intra-Cardiac Suction Tip- Rigid - 20F ( 6.7Mm ) Fluted Pool Tip- With 16F ( 5.3Mm ) - Angled Metal Shaft At Least 15 Cm Long - Spr , Frazier Tip- Suction - Small & Short6f Tip & Shaft - About 7.5Cm Long - Spr , Frazier Tip- Suction - Small & Long 6F Tip & Shaft - About 15Cm Long - Spr , Frazier Tip- Suction - Large -10 F Tip & Shaft - About 10 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 1:20 Ftip Withmetal Weighted Perforated Pooltip& Flexible Tubingat Least 30 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 2:12 Ftip Withmetal Weighted Perforated Pooltip& Flexible Tubingat Least30 Cm Long - Spr , Intracardiac / Pericardial Sump Suctiontype 3:20 Ftip With Spring Encased Fluted Pool Tip & Flexible Tubingat Least 30 Cm Long Terminating Into A 1 / 4" Connector- Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 10F ( 3.3 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 13F ( 4.3 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type 1 ) Pvc Tip With Malleable Body 15F ( 5 Mm ) With Vented Connector - Spr , Left Heartvent Catheter ( Type2 ) Silicone Tip With Malleable Introducer 16F ( 5.3 Mm ) - Spr , Left Heartvent Catheter ( Type2 ) Silicone Tip With Malleable Introducer 20F ( 6.7 Mm ) - Spr , Left Atrial Pressure Monitoring Catheter - 3F ( 1Mm ) = 20 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Left Atrial Pressure Monitoring Catheter - 4F ( 1.43Mm ) = 17 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Left Atrial Pressure Monitoring Catheter - 5F ( 1.7Mm ) = 15 G Set Of At Least 50 Cm Long With Depth Markings, Attached To A Female Luer, Peelaway Needle Tip And A Self Adhesive Anchoring Collar For Securing The Catheter At The Desired Location - Spr. , Disposable Yankur Suction Cannula With Transparentconnecting Tube Of At Least 1 Meter Long , Red Rubber Latex Catheters - 8F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Red Rubber Latex Catheters - 8F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Red Rubber Latex Catheters - 10F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Red Rubber Latex Catheters - 12Ffor Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Red Rubber Latex Catheters - 14F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Red Rubber Latex Catheters - 16F For Vessel Snugging - High Quality And Tension Resistant Body - At Least 16" Longoveral.-Spr , Vascular Tourniquet ( Snugger ) Set Adult ( 7" Long ) For Open Heart Surgery - Color Coded 4 Tubes With One Snare- For Snugging The Purse String Sutures During Open Heart Procedures - Spr , Vascular Tourniquet ( Snugger ) Set Pediatric ( 6" Long ) For Open Heart Surgery - Color Coded 4 Tubes With One Snare- For Snugging The Purse String Sutures During Open Heart Procedures - Spr , Silicone Vessel ( Vascular ) Loop - Large Size Sterile Medical Grade Radioopaque Silicone Loop 2 To 2.5 Mm Wide , < 1.2 Mm Thick & At Least 40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Silicone Vessel ( Vascular ) Loop - Small Size Sterile Medical Grade Radioopaque Silicone Loop 1 To 1.3 Mm Wide, < 1 Mm Thick & At Least 40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Silicone Vessel ( Vascular ) Loop - Tinysize Sterile Medical Grade Radioopaque Silicone Loop 0.5 Mm Wide, < 0.4 Mm Thick & At Least40 Cm Long. For Encircling The Blood Vessels During Dissection. To Be Available In At Least 3-4 Colors ( In Each Size ) - Preferablyindiviual Loop Packed In A Separate Foil. The Cost Of A Single Loop Will Be Takenfor Comparison Purpose And Hence The Number Of Loops Present In A Single Pack Needs To Be Mentioned -Spr , Air-Cushioned- Silicone Vessel ( Vascular ) Loopwith Needle -Medical Grade Siliconeloop With Hollow Interior For The Air-Cushion Effect - With The Maximumdiameter Of The Loop Less Than1.3 Mm ( Thickness ) Andat Least25 Cm Long- Spr , Temporaryepi-Myocardialpacing Wire - Adult Type - At Least 60 Cm Long For Intraoperative Placement During Cardiac Surgery- Incorporating Astraight Cutting Needle Of At Least 60 Mm Longwith ‘Breakaway’ Feature Enabling The Remaining Butt To Be Used As A Connecting Plug To The Pace Maker. The Other End Of The Wire Should Have 25 To 27 Mm Tapercut 1 / 2 Circle Needle -Spr , Temporary Epi-Myocardial Pacing Wire - Pediatric Type - At Least 60 Cm Long For Intraoperative Placement During Cardiac Surgery- Incorporating Astraight Cutting Needle Of At Least 60 Mm Longwith ‘Breakaway’ Feature Enabling The Remaining Butt To Be Used As A Connecting Plug To The Pace Maker. The Other End Of The Wire Should Have 16 To 18 Mm Tapercut 1 / 2 Circle Needle -Spr , Sternalclosure Polymer Bands Sterile Bands ( Of Less Than 5 Mm Width ) Made Of Biocompatible & Mri Compatible Poly-Ether-Ether-Ketone Polymer Substance In A Pack Of 5 Bands - These Bands Must Be Amenablefor Being Cut Open With Standardwire Cutters In Case Of Sternal Re-Entry Procedures. , Coronaryshunts ( Silicon Type ) 1 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.25 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.5 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 1.75 Mmm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Coronaryshunts ( Silicon Type ) 2 Mm- For Intra-Operative Use For Cabg ( Coronary Artery Bypass Graft ) – With Beveled & Bulbed Tips –With14 Mm Long & Clear Shaft. Spr , Disposable Aortic -Vascular Punch 2.5 To 2.8 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 3 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 3.5 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Disposable Aortic -Vascular Punch 4 Mm - With Smooth Telescoping Movement & Adequate Finger Grip Mechanism. Spr , Angled Disposable Bull Dog Type Vascular Clamp-Type Awith Clamping Pressure Of 10-15Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Bwith Clamping Pressure Of 20-25Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Cwith Clamping Pressure Of 75-80Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Angled Disposable Bull Dog Type Vascular Clamp-Type Dwith Clamping Pressure Of 165-175Gusedfor Cabg.. Should Be Radiopaque & Light Weight With Atraumatic Jaw Types- Spr . , Suction Based Cardiac Stabilizer -Retracting Arm Unit Type ( Octopus Like ) For Opcab ( Off Pump Coronary Artery Bypass ) .The Retracting Arms Unit Should Have Surgeon Controlled Pod-Spread, Allowance For Multiple Device Positions Including Pods-Up, Pods-Down And Pods-To-The-Side Applications, One-Handed Engagement Of Clamp And Turret Assembly. , Suction Based Cardiac Stabilizer - Apex Positioner ( Starfish Like ) For Opcab ( Off Pump Coronary Artery Bypass ) .Should Enhance Lifting The Apex Of The Heart And Fixing To Any Positon. , Mist Blowing Device For Opcab ( Off Pump Coronary Artery Bypass ) . With Fluid / Gas Mixing Technology Creating A Consistent, Predictable Blood Clearing Mist. On / Off Control In Hand-Piece - Malleable Shaft - Specialized Nozzle, Utilizing A Micro-Orifice For Fluid Delivery And A Separate Orifice For Gas Delivery- Spr , Vessel Cannula - 3 Mm Tip -With Stepped Contour - Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. , Vessel Cannula - 2 Mm Tip -With Stepped Contour - Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. Transparent Body & A Female Luer At One Endfor Checking The Patency And Leak In The Harvestedgrafts - Length About 5 Cm Spr. , Ima ( Internal Mammary Arterial ) Cannula -1Mm - With Bulb Shaped Tip For Checking Patency Of The Artery , Arteriotomy Cannula -2 Mm With Polyurethane Tube With A Bulb Shaped Tip Connected To A Winged Female Luerabout 5 Cmlong - Spr , Custom Madeelastic Stockings For Lower Limbs With Suitableapplier- Made Up Of A Mix Of Cotton, Polyamide & Elastane. ( Quote Only The Price Of A Single Stocking Not Of A Pair ) For Patients After Venous Harvest Or With Varicose Veins - Spr , Valves General Instructions The Valves Have To Be Supplied On Consignment Basis Such That- A Stock Of One Valve In Each Size Should Be Made Available In The User Area ( Ctvs-Ot ) And After The Utilization Of A Valve Of Particular Size, The Same Has To Be Replaced To Fill The Stock By The Firm Who Supplied The Valve. The Infromation Ofutilization Of The Valve Has Tobe Conveyed To The Supplier By The Storekeeper Who Inturn Will Be Informed By The Sno Of Ctvs Ot. , Tilting Disc Aortic Valve 18 / 19 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 20 / 21 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 22 / 23 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Aortic Valve 24 / 25 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 25 / 26 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 27 / 28 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 29 / 30 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Tilting Disc Mitralvalve 31 / 32 Mm. The Valve Should Be Rotatable After Seating. Valve To Be Supplied With The Suitable Holder.Two Sets Ofvalve Sizer & Valve Testerhave To Be Suppied With Suitable Trays ( Irrespective Of The Number Of Valves Purchased ) For The Year , Bileafletaorticvalve 16 / 17 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 18 / 19 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 20 / 21 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 22 / 23 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 24 / 25 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletaorticvalve 26 / 27 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileaflet Mitralvalve 16 / 17 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 18 / 19 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitral Valve 20 / 21 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitral Valve 22 / 23 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 24 / 25 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 26 / 27 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 28 / 29 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bileafletmitralvalve 30 / 31 Mm To Be Supplied With The Suitable Holder, Sizer And Leaflet Tester Have To Be Suppied Along With The Valve.Purchase Will Be Made Individually Whenever Necessary On Sos Basis ( Consignment Mode ) . , Bovinepericardial Stented Bioprosthetic Aortic Valve19 / 20Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 21 / 22 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 23 / 24 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base. With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve 25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base. With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Aortic Valve29 / 30Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve 27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve29 / 30 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve31 / 32 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bovinepericardial Stented Bioprosthetic Mitralvalve 33 / 34 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofile Supra-Annular Fit Valve With Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 19 / 20Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 21 / 22 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcinestented Bioprosthetic Aortic Valve 23 / 24 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve 25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcinestented Bioprosthetic Aortic Valve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Aortic Valve29 / 30Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowestprofile Height& Loweststent Base.With Suture Markers& Contoured And Compliant Sewing Ringwith The Smallest Possible Diameter. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve25 / 26 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve27 / 28 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve29 / 30 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve31 / 32 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall. To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Porcine Stented Bioprosthetic Mitralvalve33 / 34 Mm Of Thelatest Generation Technology Of The Quoted Brand With Lowprofilewith Asymmetric Design To Position The Posterior Strut Away From Lv Wall.To Be Supplied With Holder & Sizer Set.Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 19 / 20 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 21 / 22 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 23 / 24 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 25 / 26 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 27 / 28 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Stentless Bioprosthetic Conduit Aortic Root With Valve - 29 / 30 Mmfor Bentall Operation. To Be Supplied With Holder & Sizer Set. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Valves Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 12 / 13 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 14 / 15 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit. Valve Size : 16 / 17 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit. Valve Size : 18 / 19 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Bioprostheticvalved Conduit ( Bovine Jugular ) For Right Ventricular To Pulmonary Arterialconduit.Valve Size : 20 / 21 Mm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) , Prostheticcomposite Aortic Valved Conduitswith Valve Size 18 / 19 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 20 / 21 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 22 / 23 Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 24 / 25Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 26 / 27 Mmforbental Operation. Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Prostheticcomposite Aortic Valved Conduitswith Valve Size 28 / 29 Mmforbental Operation.Should Beincorporated Withprosthetic Bileaflet Valvemounted On To Collagenimpregnated Synthetic Tube Grafts. Should Be Supplied With Valve Holder, Valve Sizer & Cauterizing Loop For Creating Perforation In The Graft. Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) .Only 1 Number In Each Size Will Be In The Shelfand Purchased As A Set During Teh First Purchase - As A Stock For Emergency , Ophthalmic Cautery- Sterile , Disposable & Battery Operated For Making Perfect Holes In The Prosthetic Vascular Grafts , Annuloplasty Complete Ring For Mitral Valve. Size : 23 / 24 Mm Near Anatomical Contour Withasymmetric Remodelling Design. Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 25 / 26 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 27 / 28 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 29 / 30 Mm Near Anatomical Contour Withasymmetric Remodelling Design. Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 31 / 32 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 33 / 34 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer.Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplasty Complete Ring For Mitral Valve. Size : 35 / 36 Mm Near Anatomical Contour Withasymmetric Remodelling Design.Should Be Supplied With Suitableholder & Sizer. Purchase Will Be Made Individually Whenever Necessary -S.O.S.On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) . A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:25 / 26 Mm. Near Anatomical Contour With Downward Angle At Septal End. Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:27 / 28 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being: 29 / 30 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being:31 / 32Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being: 33 / 34 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:35 / 36 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer . Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type- ( Largest Inner Diameter Being: 37 / 38 Mm.Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Annuloplastyring For Tricuspid Valveincompletering Type - ( Largest Inner Diameter Being:39 / 40 Mm. Near Anatomical Contour With Downward Angle At Septal End.Should Be Supplied With Suitableholder & Sizer .Purchase Will Be Made Individually Whenever Necessary -S.O.S. On Consignment Basis ( I.E Different Sizes Are Brought For A Procedure - Payment Will Be Effected For The Size Utilized - The Other Size Will Be Returned ) A Set Of One Number In Each Size Will Be Purchase At First And Remain In The Shelffor Emergency. , Suture Guide / Suture-Grip / Suture-Organizer Of Gabbay Fratermechanism For Heartvlave Operationscurved Profile With Capacity To Hold At Least 8 Paired Sutureswith Positional Numbering Labelled In A Guide With Fixation Ports. Each Sterile Pack Should Contain3 Such Guides. , Arterial Embolectomy Caztheter 2F X 60 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 3F X 80 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 5F X 80 Cm - Enclosed In A Rigid Case - Spr , Arterial Embolectomy Caztheter 7F X 80 Cm - Enclosed In A Rigid Case - Spr , Ptfe Vascular Tube Grafts 3 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 3.5 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 4 Mm -At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 4.5 Mm-At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 5 Mm-At Least 10 Cm Long ( Peferably Thin Walled ) , Ptfe Vascular Tube Grafts 6 Mm -At Least 10 Cm Long , Ptfe Vascular Tube Grafts 7 Mm -At Least 10 Cm Long , Ptfe Vascular Tube Grafts 8 Mm-At Least 10 Cm Long , Ptfe Vascular Tube Grafts 6 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 7 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 8 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 12 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 14 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 16 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 18 Mm-At Least 30 Cm Long , Ptfe Vascular Tube Grafts 20 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 22 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 24 Mm -At Least 30 Cm Long , Ptfe Vascular Tube Grafts 5 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 6 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 7 Mm -At Least50cm Long , Ptfe Vascular Tube Grafts 8 Mm-At Least50cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 6 Mm - At Least 70Cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 7 Mm - At Least 70Cm Long , Ptfe Vascular Tube Grafts - With External Support ( Ringed ) 8 Mm - At Least 70Cm Long , Axillo-Bifemoralptfe Vascular Tube Grafts- 8 Mm Diameter & Length Of 90 Cm Plus50 Cm. Purchase Will Be Made Individually Whenever Necessary -S.O.S. , Cuffed Eptfe Graft With Trim Line Of 4-6 Mmx 60 Cm- For Ananstamosis With The Small Recepient Vessel Of Size -3Mm & Less. Preferably Within-Built Antiplatelet / Antithrombotic Mechanism. , Cuffed Eptfe Graft With Trim Line Of 4-6 Mmx 90 Cm- For Ananstamosis With The Small Recepient Vessel Of Size -3Mm & Less. Preferably Within-Built Antiplatelet / Antithrombotic Mechanism. , Av Accesseptfe Graft-6Mm X 40 Cm Designed Specially Forforcreating Av Fistual Creation For Hemodialysis. The Graft Should Be Able To Withstand Multiple Needle Punctures Without Bleeding After The Needle Is Removed. , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia:20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 32 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 34 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 15 Cm Long - Dia: 36 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 32 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 34 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 36 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 30 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 8 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 16 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 18 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 20 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 22 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 24 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 26 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 28 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 60 Cm Long - Dia: 30 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 6 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 7 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 10 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 12 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 14 Mm , Collagen Impregnatedpolyester Straight Tube Grafts With Crimps - 90 Cm Long - Dia: 16 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 12 Mm X 6 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 14 Mm X 7 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 16 Mm X 8 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 18 Mm X 9 Mm , Collagen Impregnated -Wovenpolyesterbifurcatedtube Grafts ( With Y Limbs ) With Crimps - 40To 50 Cm Longand Size ( Diameter ) Of Limbs : 20 Mm X 10 Mm , Polyester Fiber Suture / Ligature5 Mm X At Least 40 Cm ( For Pulmonary Arterialbanding ) Spr , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 4-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 5-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Eptfe Sutures For Valve Repairsdouble Armed –90 Cm With Taper Point 3 / 8 Circle Needles –Preferably With Needle To Suture Rationearer To Or Equivalent To 1:1. In Terms Of Tensile Strength Suture :The Size : 6-0 ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Polybutester Suture With Polytribolate Coating With The Property Of Needle Hole Self-Sealing For Vascular Anastamoses. Size 7-0 X 60 Cm With 3 / 8 Circle8mm Needle ( Cost Of Each Foil Has To Be Quoted, In Case Of Quoting The Cost For A Box, The No.Of Suture Fooils In Each Box Should Be Mentioned ) , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 5Cmx 10 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 10Cmx 10 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type A ( Woven Fabric ) - 0.25 Mm Thick. - 15Cmx 15 Cmpreferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 6 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 8 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 8 Mm X 152 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 25 Mm X 76 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type B ( Woven Fabric ) - 0.36 Mm Thick. 25 Mm X 152 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 25 Mm X 50 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 25 Mm X 100 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 50 Mm X 50 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 75 Mm X 75 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type C ( Woven Fabric ) - 0.44 Mm Thick. 100 Mm X 100 Mm- Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:6 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:10 Mm X 140 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:20Mm X 140Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Typed ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25Mm X 50 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 100 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:25 Mm X 150 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 50 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:50 Mm X 150 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:75 Mm X 75 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type D ( Woven Fabric ) - 0.61 - 0.65 Mm Thick - Size:100 Mm X 100 Mm- The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :25Mmx 152 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :51Mmx 76 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type E ( Double Velour- Woven Fabric ) - 0.46 Mm Thick-Size :51Mmx 152 Mm Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 6 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 6 Mm X 122 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 8 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 8 Mm X 152 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 25 Mm X 76 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 25 Mm X 152 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 50 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 60 Mm X 30 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 70 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 80 Mm X 40 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 100 Mm X 15 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 120 Mm X 40 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type F ( Double Velour- Knitted Fabric ) - 0.76 Mm Thick.Size: 120 Mm X 80 Mm.Preferably Collagen Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 25 Mm X 50 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 25 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 50 Mm X 50 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick - 50 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Patch - Type G ( Double Velour- Knitted Fabric ) -1.5 Mm Thick -100 Mm X 100 Mm As Used For Closure Oflarge Vsd. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Pet ( Polyethylene Pteriphthalate ) Patch About8 Mm X 75 Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About25 Mm X 76 Mm - Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 25 Mm X 152Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 50 Mm X 76 Mm - Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Pet ( Polyethylene Pteriphthalate ) Patch About 50 Mm X 152 Mm -Aldehyde-Free. Gel Coated. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 20 Mm X 30 Mm Made Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 20 Mm X 75 Mm Made Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 15 Mm X 20 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) - 8 Mm X 30 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -6 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -8 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -10 Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type A. ( 0.3 Mm Thick ) -20 Mm X 90Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) -8Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) -10 Mm X 90 Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 25Mm X 150Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 30Mm X 30Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 30Mm X 60Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfetrilaminar Patch - Type B. ( 0.5 Mm Thick ) - 50Mm X 75Mmmade Up Of Triple Layers ( Eptfe Layers With Middle Layer Of Thermoplastic Fluropolymer With Elastic Property ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 10 Mm X 90 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 20 Mm X 90 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type C ( 0.4 Mm Thick ) - 30 Mm X 60 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 30 Mm X 30 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 50 Mm X 75 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 25 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 50 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Eptfe Patch - Type D ( 0.58To 0.62 Mm Thick ) 100 Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 50 Mm X100 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 100 Mm X100 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Patch ( 0.9 Mm Thick ) 150 Mm X150 Mm For Outflow Tract. The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Polyester Felt1.65 Mm Thick -150Mm X 150 Mm The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felts- 1.65 Mm Thick 12 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick25 Mm X 25 Mm , Ptfe Felts- 1.65 Mm Thick25 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick 25 Mm X 150 Mm , Ptfe Felts- 1.65 Mm Thick 50 Mm X 50 Mm , Ptfe Felts- 1.65 Mm Thick100 Mm X 100 Mm , Ptfe Felts- 1.65 Mm Thick150 Mm X 150 Mm , Ptfe Felt With Low Porosity - 1.85 Mm Thick - 25 Mm X 25 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felt With Low Porosity -1.85 Mm Thick - 100 Mmx 100 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Ptfe Felt With Low Porosity -1.85 Mm Thick - 150Mm X150 Mm ( For Aortic Graft Anastamotic Line Augmentation ) .The Brochure Containing The Necessary Details On The Dimensions And The Material Of The Fabric Has To Be Submitted. The Specification For Thickness Has To Be Adhered Whereas The Length Or Width Can Exceed The Specified. , Tissue Engineered Pericardial Patch4 Cm X 4Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch6 Cm X 6 Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch8 Cm X 8Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Tissue Engineered Pericardial Patch10cm X 10 Cm With Intact Extracellular Matrix Devoid Of Bovine Cells -Treated With Anticalcification Technology Without Gluteraldehyde Treatment - Non-Cytotoxic , Non-Antigenic, Nonthrombogenic, Flexible & Ultrathin ( 2 To 5Mm Thick ) With Goodsuturabilitywith At Least 1 Year Shelf Life. , Ptfepledgets Thickness X Breadth & Length : 0.5Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgets Thickness X Breadth & Length : 1 Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgetsthickness X Breadth & Length :1 Mm X 3 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgets Thickness X Breadth & Length : 1.5Mm X 3 Mm X 3 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfepledgetsthickness X Breadth & Length : 1.5Mm X 3 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfe Feltpledgetsthickness X Breadth & Length : 1.65 Mm X 4.8Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Ptfefelt Pledgets Thickness X Breadth & Length :1.65 Mm X 6 Mm X 6 Mm For Vascular And Cardiac Sutures -Specify The Number Of Pledgets In A Pack And The Rate Of The Pack Clearly.Spr , Topical Hemostatic : Fibrinogen- Human Thrombin- Aprotinin -In Prefilled Syringes Applicatorwith Atotal Volume Of10 Ml In A Pack. Spr , Topical Hemostatic : Polythylene Glycol - 4 Mlfor Raw Surfaces Oflung For Hemostatic And Also For Preventing Air Leak And Alsopreventive Usage Incardiac / Vascularsuture Lines , Topical Hemostatic- Albumin Gluter-Aldehyde Glue -Total Volume Of 10Ml Per Packcontained In The Prefilled Syringes Andforming A Strongbut Flexiblelayer Of Seal- Compatible To Fix The Separated Layers Of Dissected Aorta. To Be Provided With Suitable Applicator For Focused Local Application. , Topical Bio-Absorbable Hemostatic: Non-Oxidativecellulose 5 X 5 Cm - Hemostatic Acting By Non--Oxidative Chemical Reaction Using Cellulose Asa Substance. , Trachealstents ( Fully Covered ) - Straight Type. Should Have Radioopaque Markers At Both The Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Trachealstents ( Fully Covered ) - Bifurcated Y Typeshould Have Radioopaque Markers At All The Three Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Bronchial Stents ( Fully Covered ) - Straight Type. Should Have Radioopaque Markers At Both The Ends. The Purchase Will Be Done As When Needed On Sos Basis ( Consignment Mode ) In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Procedure And After The Usage The Rest Of Thestents Can Be Taken Back. The Various Available Sizes And Length May Be Mentioned While Quoting. The Most Commonly Used Two Sizes Will Be Purchased At First As An Emergency Stock And The Rest Of The Purchase Will Be By Consignment Mode. Size Ordered Will Be Based On The Patients Condition , Guidewire For Deployingthe Tracheal Stent - The Selection Will Be Based On The Compatibility Wit The Brand Selected For The Tracheal Stent . , Thoracic Aortic Stent Grafts - Straight Type :To Be Supplied With The Suitable Delivery System With Smallest Possible Catheter Outer Diameter.The Stent Should Be Mri Compatible. The Purchase Will Be Done As When Needed, In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Surgery And After The Usage The Rest Of Thestents Can Be Taken Back - I.E Consignment Mode. The Various Available Sizes And Length May Be Mentioned While Quoting. ( Size Ordered Will Be Based On The Patients Condition ) , Thoracic Aortic Stent Grafts - Bifurcated Y Type :To Be Supplied With The Suitable Delivery System With Smallest Possible Catheter Outer Diameter.The Stent Should Be Mri Compatible. The Purchase Will Be Done As When Needed, In Which Case, A Set Of Various Sizes Of Stentsto Be Brought On The Day Of Surgery And After The Usage The Rest Of Thestents Can Be Taken Back - I.E Consignment Mode. The Various Available Sizes And Length May Be Mentioned While Quoting. ( Size Ordered Will Be Based On The Patients Condition ) , Sterile Guidewire Suitable To Fit 16G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 18G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 20G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire Suitable To Fit 22G Needle - For Seldinger Technique - With Minimum Length Of 50 Cm - Spr , Sterile Guidewire - 0.038 Inchfor Femoral Vessel Cannulation , Femoral Puncture Needle - 16G - For Seldinger Technique - At Least 180 -200 Cm Long.Spr. , Cabg Drape Kit With9 Components: ( Totally15+1Parts In A Pack ) Go Through The Link For Detailed Specifications: Https: / / Docs.Google.Com / Document / D / 1Yoteirccpx3apbvgbx438oyfictzx77splq3xk4zapa / Edit , General Open Heart Drape Kit Containing The Following Components. ( Totally10+1Parts In A Pack ) Go Through The Link For Detailed Specifications:Https: / / Docs.Google.Com / Document / D / 1_H3eesdoj0ticagchls5bvnmxgqff3lw9ptypavhcke / Edit?Usp=Sharing , Sternalwound Dressing Pad - Sterileadhesive Polyurethane Film With Absorbent Pad, 20 X 10 Cm - Spr , Montogomer T-Type Silicon Tracheostomy Tube - Spr , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-26Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-28Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-32Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-35Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-37Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-39Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Left Sided-41Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-26Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-28Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-32Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Right Sided-35Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) -Rightsided-37Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) - Rightsided-39Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Double Lumen Endotracheal Tube ( Dlet ) -Rightsided-41Ftransparent Double Lumen Cuffed Endobronchialtubehaving Smooth Gliding Surface Radioopaque Line & Sensitive Pilot Balloons With Separate Color Coding For Bronchial And Tracheal Lumens And Balloons. ( Spr For For Any One Size ) , Endo-Bronchial Blockers - Withballoon - Ardnt Type - For One Lung Ventilation - Wire Loopguide And Suitable Adapterforbronchoscope. , Endo-Bronchial Blockers - Withballoon -Cohentype - For One Lung Ventilationwith Flexible Defelcting Tip With Suitable Adapter To Faciltate Bronchoscope. , Endo-Bronchial Blockers - Withballoons -Eztype - With Y-Tipped For One Lung Ventilation , Ultrasonic Nebulizer -Spr Fordemostration. Or Product Catalogue Brochure With Figure To Be Submitted. , Soft Vinyl Percussors For Performing Chest Physiotherapy Indifferent Sizes , Electro Surgical ( Cautery ) Pencils - ( Electrosurgical Electrode ) With Long Arm- Spatula Tip &Hand Control Oftwin Switch Type For Cutting And Coagulation Modes-Should Be Compatible With Martin & Alancautery ( Electrosurgical ) Machines. Prefererable Dimensions:Shaft Diameter Less Than 2.5 Mm. Shaft Length -130-140 Mm Spatula Dimension - About 20 X 2.5 X 0.5 Mm Appropraite Certification For Electrical Safety Should Be Confirmed. - Spr , Disposable Microscalpel Withhigh Qualitymicro-Blade Attached For Coronary Arteriotomy - Spr , Sterile Cover For Echocardio-Graphicprobefor Use In The Operative -Field. Should Fit Universally All Utrasound Probes Commonly Used During Cardiac Surgery With Special Fold To Accomdatethe Probe End Without Wrinkles. Should Be Made Up Of Clear Transparent Latex Free Medical Grade Material - Polythene.Length Of Cover - 150 Cm;Width Of The Cover - 10 Cm. The Kit Should Also Contain Securing Tapes To Hold The Cover Around The Probe And Preferably With Ultrasound Transmission Gel - Pack. , Non-Consumables , De Bakeystraightfinevascularforceps - Short ( 18Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakey Straightfinevascularforceps - Medium ( 25Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakeystraightfinevascularforceps - Long ( 30Cm ) Jaw ( 1.5 X 14Mm ) 5Mm Wide Shaft , De Bakey Angled 45º Finevascular Fine Forceps - Short ( 18Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakey Angled 45º Finevascular Forceps - - Medium ( 25 Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakeyangled 45ºfine Forceps Vascular - Long ( 30 Cm ) With Smooth Jaw ( 1.5 X 14 Mm ) &5Mm Wide Shaft - For Ima Dissection , De Bakeydouble Actionstraightfinevascularforceps - Short ( 18Cm ) - With 1X2 Teeth - Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightfinevascularforceps - Medium ( 25Cm ) - With 1X2 Teeth -Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightfinevascularforceps - Long ( 30Cm ) - With 1X2 Teeth - Jaw ( 1.5 X 10Mm ) 4-5Mm Wide Shaft , De Bakeydouble Actionstraightvascularforceps - Short ( 18Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraightvascularforceps - Medium ( 25Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraight Vascularforceps - Long ( 30Cm ) With 1X2 Teeth- Jaw ( 2.5-2.8X 12Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraighttissueforceps - Short ( 18Cm ) With 1X2 Teeth- Jaw ( 3 X 14 Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraighttissue Forceps - Medium ( 25Cm ) With 1X2 Teeth- Jaw ( 3 X14mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionstraight Tissueforceps - Long ( 30Cm ) With 1X2 Teeth- Jaw ( 3 X 14 Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Short ( 18Cm ) With3 X2 Teeth - Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Medium ( 25 Cm ) With3 X2 Teeth- Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , De Bakeydouble Actionextra-Large Straighttissueforceps - Long ( 30Cm ) With3 X2 Teeth - Jaw ( 5 X 28Mm ) 4-6Mm Wide Shaft , Resano Atruamatic Forceps - Short ( 18 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Forceps - Medium ( 25 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm & 4-6 Mm Wide Shaft. , Resano Atruamatic Forceps - Long ( 30 Cm ) - Straight Jaws-2.5 -3 Mm X 14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Forceps-Short ( 18 Cm ) - Straight Jaws-14 Mm & 4-6 Mm Wide Shaft. , Resano Atruamaticdouble Action Forceps-Medium ( 25 Cm ) -Straight Jaws-14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Forceps-Long ( 30 Cm ) - Straight Jaws14 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Largeforceps-Short ( 18 Cm ) -Straight Jaws-18 Mm & 4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Large Forceps-Medium ( 25 Cm ) -Straight Jaws18 Mm &4-6 Mm Wide Shaft. , Resano Atruamatic Double Action Large Forceps-Long ( 30 Cm ) -Straight Jaws-18 Mm & 4-6 Mm Wide Shaft. , Gemini Double Action Diliating, Curved, Smooth Forceps ( 31-37 Cmlong ) With 1 X 2 Teeth, Jaw Length - 30 Mm, Shaft Dia 4-6 Mm , Rongeur For Valve - 30º Curved Tip ( 31-37 Cm Long ) Jaw Size - 3.5 Mmshaft Dia: 4-6 Mm , Rongeur For Valve - Straighttip ( 31-37 Cm Long ) Jaw Size - 3.5 Mm Shaft Dia : 4-6 Mm , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 120 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 90 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - 30 - 36 Cm Jaw Size - 60 Mm- ( 2 X 3 Teeth ) , Debakey -Chitwood Aortic Cross Clamp -Slim - 30 - 36 Cm Jaw Size - 120 Mm- ( 1 X 2 Teeth ) , Debakey -Chitwood Aortic Cross Clamp -Slim30 - 36 Cm Jaw Size - 90 Mm- ( 1 X 2 Teeth ) , Debakey -Chitwood Aortic Cross Clamp - Slim 30 - 36 Cm Jaw Size - 60 Mm- ( 1 X 2 Teeth ) , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type18 Inches Longwith Straight Jaw ( 30-35 Mm ) With Insert. , Spareinserts ( 30-35 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No.Nc37 Mention The Cost Of A Pair Of The Insert , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type- 18 Inches Longwith Straight Jaw ( 60-65 Mm ) With Inserts. , Spareinserts ( 60-65 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No. Nc39mention The Cost Of A Pair Of The Insert , Cosgrove Type Flexible Shaft Aortic / Vascular Atrumaticclamp - Fogarty Type18 Inches Longwith Straight Jaw ( 85-90 Mm ) With Inserts. , Spareinserts ( 85-90 Mm ) For Cosgrove Clampscompatible To The Brand Selected For The Clamp Mentioned In The Item No. Nc41 Mention The Cost Of A Pair Of The Insert , Nerve Or Vessel Hook - Ball Tiptotal Length : 32-37 Cmwith Working Length -23 Cm Tip Length :10 Mm , Nerve Or Vessel Hook- Fine Tip Total Length : 32-37 Cmwith Working Length -23 Cm Tip Size :1 X 6Mm , Nerve Or Vessel Hook Standard Tip Total Length : 32-37 Cmwith Working Length -23 Cm Jaw Size:2 X 10Mm , Nerve Or Vessel Hook - 90ºwith Fine Tip. Total Length : 32-37 Cmwith Working Length -24-28 Cm Jaw Length :4-7 Mm , Jacobsonmicroscissors 25º -Round Handle -16 To 20 Cm , Jacobsonmicroscissors 45º -Round Handle -16 To 20 Cm , Jacobsonmicroscissors 60º - Round Handle -16 To 20 Cm , Jacobsonmicroscissors 90º - Round Handle -16 To 20 Cm , Jacobsonmicroscissors 125º -Round Handle -16 To 20 Cm , Potts / Potts Smith / Diethrich-Potts Scissors 25º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 45º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 60º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 90º - ( 16 To 20 Cm ) , Potts / Potts Smith / Diethrich-Potts Scissors 125º- ( 16 To 20 Cm ) , Iris Scissors - Ring Handle With Fine Straight Tips -10 To 12 Cm , Iris Scissors - Roundhandle With Fine Straight Tips -10 To 12 Cm , Debakeyscissors 25º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 45º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 60º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 90º - ( 16 To 20 Cm ) - Ring Handle , Debakeyscissors 125º - ( 16 To 20 Cm ) - Ring Handle , Favaloro Vascular Scissors 125º - ( 16 To 20 Cm ) - Ring Handle , Metzenbaum Scissors ( Standard ) 16-20 Cm - Curved Blades - Ring Handle , Metzenbaum Scissors ( Long ) 20-25 Cm - Curved Blades - Ring Handle , Metzenbaum Scissors ( Extra-Long ) 30-32 Cm - Curved Blades - Ring Handle , Mayo Scissors - Straight Round - Standard - 17-20 Cm , Mayo Scissors - Curved Round - Standard - 19-23 Cm , Mayo-Harrington Scissors - Straight- 30-32 Cm , Wire Cutter - Double Action -Tungsten Carbide Edge 17-20 Cm , Rib Shears ( Gluck Type ) - 18-20 Cm , Rib Shears ( Bethune ) - 32-36 Cm , Yankauer Suction Tube- 28-35 Cm , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.10 , Standard Scalpel Handle -Short12-14 Cmfor Blade No.11 , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.15 , Standard Scalpel Handle -Short 12-14 Cmfor Blade No.23 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.10 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.11 , Standard Scalpel Handle -Long 21-23 Cmfor Blade No.15 , Standard Scalpel Handle -Long21-23 Cmfor Blade No.23 , Jacobson Needle Holder - Long ( 24-25 Cm ) For 2-0, 3-0 & 4-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Short ( 18-20 Cm ) For 2-0, 3-0 & 4-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Long ( 22-24 Cm ) For 5-0& 6-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Needle Holder - Short ( 18-20 Cm ) For 5-0 & 6-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Micro-Needle Holder - Long ( 22-24 Cm ) For7-0 & 8-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Jacobson Micro-Needle Holder - Short ( 18-20 Cm ) For7-0 & 8-0 Sutures With Diamond Coatedstraight Jaws & Spring Style Round Handle With Ratchet & Stream Line Box Lock , Richards Micro Needle Holder -18-20 Cm For 6-0, 7-0 &8-0 Sutures Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Ryders Needle Holder 18-20 Cmfor 5-0 Sutures With- Diamond Coated Tip With Straight Jaws &Ring Handlewith Ratchet , Debakey Needle Holder 24-25 Cmfor 5-0 Sutures With- Diamond Coated Tip With Straight Jaws &Ring Handlewith Ratchet , Debakey Needle Holder 15-16 Cmfor 2-0, 3-0 & 4-0Sutures With- Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Debakey Needle Holder 20-22 Cmfor 2-0, 3-0 & 4-0Sutures With- Diamond Coated Tip With Straight Jaws & Ring Handlewith Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 23-25 Cm With Tungsten Cardbide Edgesring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 20-21 Cm With Tungsten Cardbide Edges Ring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 18-19 Cm With Tungsten Cardbide Edges -Ring Handle, - With Ratchet , Hegar Vascular Needle Holderwith 1 Mm Wide Jaw- 14-15 Cm With Tungsten Cardbide Edges -Ring Handle, - With Ratchet , Titaniumdennis Micro-Forceps ( Straight ) - 1 Mm Ring Tip - 18-20 Cm Counter - Balancedround Handle With Diamond Coating - , Titaniumdennis Micro-Forceps ( Straight ) -Pointed Platform Tip -18-20 Cm- Counter-Balancedround Handle With Diamond Coating - , Titaniumdennis Micro-Forcepsstraight Standard 1Mm Tip 18-20 Cm Round Handle With Diamond Coating , Titaniumgeraldmicro-Forcepsstraightring Tip 1Mm-18-20 Cm - Round Handle& Diamond Coating , Titaniumgeraldmicro-Forcepsstraight Platform Tip 1Mm 18-20 Cm - Flathandle& Diamond Coating , Titaniumgeraldmicro-Forcepsstraight Tip 1Mm 18-20 Cm - Withflat Handle , Titaniumdebakey Dissection -Forceps -Straight Tip 1Mm 18-20 Cm -Flat Handle , Titaniumdebakey Dissection -Forceps -Straight Tip 2 Mm 18-20 Cm -Flat Handle , Hegar Heavy Needly Holder - 20 Cm With Tungsten Carbide Edges - Jaw Width Tapering From5 Mm To 3 Mm With Jaw Length About 20 Mm , Heavy& Long Needle Holder -27 Cm With Tungsten Carbide Edges - Jaw Width Tapering From5 Mm To 3 Mm With Jaw Length About 20 Mm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Sep-2021 Date Corriendum Date 18-09-2021
2 18-Sep-2021 Date Ext Date 25-09-2021

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Rate Contract for supply of consumables and non-consumables for the Department of Cardiothoracic and Vascular Surgery JIPMER, Puducherry – 605 006
Sl. No. Item Description
1Perfusion Technological Consumables-Abbreviations Used MSA - Membrane surfaceArea, BFR - Blood Flow rate SPV - Static Priming Volume,CVR - Cardiotomy venous reservoir. PV - Priming volume, BHPSC - Biocompatible hydrophilic polymer surface coating, HE - Heat Exchanger.SS - Stainless Steel SPR - Sample to be Provided
2Membrane Oxygenator-Large Adult- Type A MSA = 1.7 to1.8m²,Max. BFR = 8L/min,SPV= 220ml, CVR = 4500ml, Surface must be coated,Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
3Membrane Oxygenator-Large Adult- Type B MSA = 1.4 to 1.8m², Max BFR =6 L/min, SPV = 185ml, CVR = 4500mlCoated Surface -Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
4Membrane Oxygenator-Large Adult- Type C MSA = 1.4 to1.8m², Max BFR = 6 L/min,SPV = 185ml, CVR = 4500ml, Integrated Arterial filter, Surface must be coated,Polyurethane HE, Primary Pack should be labelled.Holder & Temperature probe to be supplied. SPR
5Membrane Oxygenator-Small Adult- Type A MSA=1.3 to 1.5 m², Max BFR= 5 L/min, SPV = 175ml,CVR = 4000ml. Biocompatible surface coating preferable. Stainles Steel HE, Primary Pack should be labelled.Holder & Temperature probe to be supplied. SPR
6Membrane Oxygenator-SmallAdult- Type B MSA = 1.3 to1.5 m²,Max BFR =5L /min,SPV =295ml,CVR = 4000ml. Integrated arterial filter,SS-HE,Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
7Membrane Oxygenator-Small Adult- Type C MSA= 1.5m²,Max BFR= 4 L/min, SPV = 135 ml, Hard shell reservoir capacity 3000-3200ml, Metal HE.Primary Pack should be labelled. Holder & Temperature probe to be supplied.SPR
8Membrane Oxygenator- Pediatric- Type A MSA = 1.1m², Max. BFR 2.8 to3.5L/min, SPV = 130ml, CVR = 2500ml,SS- HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
9Membrane Oxygenator - Pediatric- Type B MSA = 0.8m², Max BFR 2.1 -2.8 L /min,SPV= 100ml,CVR = 1500ml,SS-HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
10Membrane Oxygenator-Pediatric- Type C MSA = 0.67m²,Max BFR = 2 L/min,SPV = 48ml. Integrated HE of Terephthalate (PET)Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
11Membrane Oxygenator- Infant MSA = 0.5m²,Max BFR = 1.5 L /min, SPV = 43ml,Integrated SS-HE. Biocompatible hydrophilic polymer surface coating .Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
12Membrane Oxygenator- Neonate MSA = 0.35m²,Max BFR= 1 L /min,SPV = 38ml,integratedSS-HE , Coated surface. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
13Membrane Oxygenator- Dual ChamberCVR integrated with arterial filter MSA = 1.6 to 1.85m², Max BFR -7 L/min, SPV = 350ml,Coated surface, Two-step lipid-leukocytes depletion CVR, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
14ECMO Oxygenator -AdultMSA =1.8m², Max BFR= 7 L/min,SPV = 250 ml. CVR=4 Lit, Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
15ECMO Oxygenator - Small Adult MSA =1.2m², Max BFR= 5L/min, SPV = 150 ml. CVR=3 Lit Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
16ECMO Oxygenator-Pediatric MSA = 0.67m², Max BFR up to 4L/min, SPV = 90 ml. CVR=2.5 Lit Diffusion membrane material Polymethyl pentenePrimary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
17ECMO Oxygenator -Neonate MSA = 0.69m²,Max BFR=1.5 L/min,SPV = 95ml.CVR = 1.5 Lit. Diffusion membrane material Polymethyl pentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
18ECMO oxygenator with circuit formultipurpose use - ADULTTYPE 1MSA =1.8m²,Max BFR= 7L/min ,SPV = 250 ml,RF-32 or Flo Pump32centrifugal Pump Head,Diiffusion membrane ofPolymethylpentene.Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
19ECMO oxygenator with circuit formultipurpose use -ADULTTYPE 2 MSA = 1.8m²,Max BFR= 7 L/min, SPV=250 ml,Vaned Impeller design ofpump head- Diffusion membrane material Polymethylpentene, - 3/8 inch inlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) & SORIN S5 (CP5), Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
20ECMO oxygenator with circuit formultipurpose use - SMALLADULTTYPE 1 MSA = 1.5m², Max BFR= 5L/min , SPV = 200 ml, RF-32 or Flo Pump32 centrifugal Pump Head, Diffusion membrane material Polymethylpentene , Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
21ECMO oxygenator with circuit formultipurpose use - SMALLADULTTYPE 2 MSA = 1.5m², Max BFR= 5L/min, SPV = 200 ml, Vaned Impeller design pump head, Diffusion membrane material Polymethylpentene , 3/8 inchinlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) & SORIN S5 ( CP5) Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
22ECMO oxygenator with circuit formultipurpose use -PEDIATRIC TYPE 1MSA =0.69m², Max BFR = 1.5.L/min, SPV =90 ml. "RF-32 or FloPump32"centrifugal Pump Head, Polymethylpentene membrane, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
23ECMO oxygenator with circuit formultipurpose use -PEDIATRIC TYPE 2 MSA = 0.69m²,Max BFR= 1.5L/min, SPV =90 ml. Vaned Impeller design pump head, Polymethylpentene membrane, 3/8 or 1/4 inchinlet & outlet with housing to fit the centrifugal console of APS-I (Terumo) &SORINS5( CP5). Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
24Hemofilter- Big Adult MSA = 1.4m², PV = 80 ml, To be supplied with tubing set & collection bag & a suitable holderPrimary Pack should be labelled.SPR
25Hemofilter- Adult MSA = 1.1m², PV=71 ml, To be supplied with tubing set & collection bag & a suitable holderPrimary Pack should be labelled. SPR
26Hemofilter- Small Adult MSA = 0.71m², PV = 65 ml,To be supplied with tubing set & collection bag & a suitable holderPrimary Pack should be labelled. SPR
27Hemofilter -Pediatric MSA=0.3m², PV= 35 ml,To be supplied with tubing set & collection bag & a suitable holderPrimary Pack should be labelled. SPR
28Hemofilter-Infant MSA =0.1m², PV= 20 ml, To be supplied with tubing set & collection bag & a suitable holderPrimary Pack should be labelled. SPR
29Arterial filter - Adult Max BFR=7 L/min, SPV = 125 ml,Pore size-37µm, Blood port= 3/8 inchBypass loop& 3-way with one-way valve purge line & a suitable holder - to be supplied.Primary Pack should be labelled. SPR
30Arterial filter - Small Adult Max BFR=4L/min, SPV = 80 ml,Pore size-37µm,Blood port= 3/8 inchBypass loop & 3-way with one-way valve purge line & a suitable holder - to be supplied.Primary Pack should be labelled. SPR
31Arterial filter - Pediatric Max BFR=2.5 L/min, SPV = 40 ml,Pore size-32µm, Blood port=1/4 inch. Bypass loop & 3way with one-way valve purge line & a suitable holder - to be supplied.Primary Pack should be labelled. SPR
32Custom pack-Adult- tubing setfor CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
33Custom pack-Small Adult -tubing setfor CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
34Custom pack-Pediatrictubing setfor CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
35Custom pack-Neonatal tubing setfor CPB as per JIPMER 2020 Circuit. (contact CTVS dept for Figures)
36ECMO Adult tubing set Custom pack as per the JIPMER2020 circuit. Primary Pack should be labelled. SPR .(contact CTVS dept for Figures)
37ECMO Pediatric tubing set Custom pack as per the JIPMER2020 circuit. Primary Pack should be labelled. SPR . (contact CTVS dept for Figures)
38Cardio plegia delivery system(CPDS) - Reservoir TypeMinimum 2-L Reservoir capacity with at least 4 x 1/4” ports with holder Primary Pack should be labelled. . SPR
39Cardio plegia delivery system(CPDS) -4:1 type PV= 30ml, Max BFR = 2.5 L/min with 3-way with purge line.Preferably withgroved stainless steel HE & 150 µm polyester screen filter.Primary Pack should be labelled. Holder to be supplied. SPR
40Centrifugal pump head -Adult type 1 Vaned Impeller design, 3/8 "inlet & outlet with housingto fit the centrifugal console of heart lung machine of APS-I (Terumo – Sarns) & SORIN S5 (CP5).SPR
41Centrifugal pump head - Adult Type 2Priming Volume = 32ml,3/8 inch inlet & outlet with housingto fit the centrifugal console of Rotaflow (Maquet). The pump head should bewithout a metal shaft or seal.SPR
42Centrifugal pump head - PediatricType 1 Vaned Impeller design, 1/4" inlet & outlet with housing to fit the centrifugal console of heart lung machine of APS-I (Terumo–Sarns) & SORIN S5 (CP5). SPR
43Centrifugal pump head - PediatricType 2 1/4" inlet & outlet with housing to fit the centrifugal console of Rotaflow (Maquet). The pump head should bewithout a metal shaft or seal. SPR
44Intra Aortic balloon(compatible with ArrowIABP machine)-30 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
45Intra Aortic balloon(compatible with ArrowIABP machine) 34 / 35 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
46Intra Aortic balloon(compatible with ArrowIABP machine)- 40 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
47Intra Aortic balloon(compatible with ArrowIABP machine)- 50 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
48Pressure transducers -Single type forheart lung machine Sarns Heart Lung machine and APS-Iwith 200 cm pressure line& a pressure cable suitable for the device and the machine has to be supplied free of cost with every100 transducers purchased-SPR
49Straight connectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A -3/16" x 3/16".
50Straight connectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B - 1/4" x1/4"..
51Straight connectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C -3/8" x 3/8".
52Straight connectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D -1/4" x 3/8".
53Straight connectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E -3/8" x 1/2".
54Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A-3/16" x 3/16" x 3/16"
55Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B-3/16" x1/4" x 1/4"
56Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C-1/4" x1/4" x 1/4"
57Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D-1/4" x1/4" x 3/8"
58Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E-3/8" x 3/8" x 3/8"
59Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size F-3/8" x 3/8" x 1/4"
60Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size G-1/2""x 3/8""x 3/8""
61Yconnectors with female luer lock - Disposable, Sterile,transparent - made up of high quality plasticsuitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size H-3/16" x 1/4" x 3/8"
62HTK type - single shot cardioplegiaHistidine – Tryptophan – Ketoglutarate (HTK) type.cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia.1 litre
63HTK type - single shot cardioplegiaHistidine – Tryptophan – Ketoglutarate (HTK) type.cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia.0.5litre
64Multiple perfusion adapter setwith 4 legs (3 long +1short leg) with individual tubing clamps for simultaneous perfusion of venous grafts and aortic root - with femaleluer inlet & maleluer outlets preferably withlength of- at least 10" (refer fig.)SPR.
65Minimally invasive vascular access Kitfor femoral arterial cannulation for CPB orECMOwithScalpel (#11), Seldinger Needle (18G) Stepped vessel dilator- 8 F/10 F,12 F/14 F& 16 F/18 F,Guidewire - 0.038" (0.965-mm)-100 cm long -forcannulation - SPR
66Minimally invasive vascular access kitfor femoral venous Cannulation for CPBorECMO With Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator- 8 F/10 F,12 F/14 F and16 F/18 F,Guidewire - 0.038" (0.965-mm)-180 cm long- SPR
67Minimally invasive Vascular access Kitfor jugular venous Cannulation for CPB orECMO With Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator- 8 F/10 F,12 F/14 F Guidewire - 0.025" (0.535-mm)-60 cm long-forcannulation SPR
68Dual lumen catheter13 F for venovenous ECMO with Insertionkit having100 cm guidewire , suitable Seldindinger puncture needle.SPR
69Dual lumen catheter16 F for venovenous ECMO with Insertionkit having100 cm guidewire , suitable Seldindinger puncture needle.SPR
70Dual lumen catheter19 F for venovenous ECMO with Insertionkit having100 cm guidewire , suitable Seldindinger puncture needle.SPR
71Dual lumen catheter20 F for venovenous ECMO with Insertionkit having210 cm guidewire , suitable Seldindinger puncture needle.SPR
72Dual lumen catheter23 F for venovenous ECMO with Insertionkit having210 cm guidewire , suitable Seldindinger puncture needle.SPR
73Dual lumen catheter27 F for venovenous ECMO with Insertionkit having210 cm guidewire , suitable Seldindinger puncture needle.SPR
74Dual lumen catheter31 F for venovenous ECMO with Insertionkit having 210 cm guidewire , suitable Seldindinger puncture needle.SPR
75Aortic / arterialPerfusion Cannula plaintype with Straighttip 8FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
76Aortic / arterialPerfusion Cannula plaintype with Straighttip 10FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
77Aortic / arterialPerfusion Cannula plaintype with Straighttip 12FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
78Aortic / arterialPerfusion Cannula plaintype with Straighttip 14FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
79Aortic / arterialPerfusion Cannula plaintype with Straighttip 16FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
80Aortic / arterialPerfusion Cannula plaintype with Straighttip 18FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
81Aortic / arterialPerfusion Cannula plaintype with Straighttip 20FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
82Aortic / arterialPerfusion Cannula plaintype with Straighttip 22FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
83Aortic / arterialPerfusion Cannula plaintype with Straighttip 24FOverall length of at least7 incheswith transparent body withtapering contour,tip orientationline and tip guardpreferably with vented type connector - SPR
84Aortic /arterialPerfusion Cannula -Angled (45 deg) wirewound - Size 20F - Overall at least12 incheswithtransparent & wirewoundbody,angled (45 deg)bevelled tip with side holes, tip orientationline and tip guardpreferably with vented type connector - SPR
85Aortic /arterialPerfusion Cannula -Angled (45 deg) wirewound - Size 22F - Overall at least12 incheswithtransparent & wirewoundbody,angled (45 deg)bevelled tip with side holes, tip orientationline and tip guardpreferably with vented type connector - SPR
86Aortic /arterialPerfusion Cannula -Angled (45 deg) wirewound - Size 24F - Overall at least12 incheswithtransparent & wirewoundbody,angled (45 deg)bevelled tip with side holes, tip orientationline and tip guardpreferably with vented type connector - SPR
87Elongated Aortic /arterialPerfusion Cannula- PediatricSize 6F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
88Elongated Aortic /arterialPerfusion Cannula- PediatricSize 8F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
89Elongated Aortic /arterialPerfusion Cannula- PediatricSize 10F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
90Elongated Aortic /arterialPerfusion Cannula- PediatricSize 12F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
91Elongated Aortic /arterialPerfusion Cannula- PediatricSize 14F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
92Elongated Aortic /arterialPerfusion Cannula- PediatricSize 16F - With elongated thin walled tip - vented type -depth markings - overalat least9 inch longwithintroducer preferablywith guide wire -SPR
93Elongated Aortic /arterialPerfusion Cannula- Adult Size 18F- with thin walledvented type tip,introducer&depth markings, radioopaque adjustable suture collar - overal length of at least 12 inch long preferably with guidewire. SPR
94Elongated Aortic /arterialPerfusion Cannula- Adult Size 20F- with thin walledvented type tip,introducer&depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire.SPR
95Elongated Aortic /arterialPerfusion Cannula- Adult Size 22F - with thin walledvented type tip,introducer&depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire.SPR
96Elongated Aortic /arterialPerfusion Cannula- Adult Size 24F- with thin walledvented type tip,introducer&depth markings, radioopaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire.SPR
97Venous Return Cannula - single stage -- straight12Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
98Venous Return Cannula - single stage -- straight14Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
99Venous Return Cannula - single stage -- straight16Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
100Venous Return Cannula - single stage -- straight18Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
101Venous Return Cannula - single stage -- straight20Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
102Venous Return Cannula - single stage -- straight22Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
103Venous Return Cannula - single stage -- straight24Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
104Venous Return Cannula - single stage -- straight26Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
105Venous Return Cannula - single stage -- straight28Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
106Venous Return Cannula - single stage -- straight30Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
107Venous Return Cannula - single stage -- straight32Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
108Venous Return Cannula - single stage -- straight34Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
109Venous Return Cannula - single stage -- straight36Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
110Venous Return Cannula - single stage -- straight38Fmultiport tapered tipwithkink resistant wirewoundbody- over all length of at least12 inch long -SPR
111Venous Return Cannula - single stage -- right angled metal 10Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
112Venous Return Cannula - single stage -- right angled metal 12Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
113Venous Return Cannula - single stage -- right angled metal 14Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
114Venous Return Cannula - single stage -- right angled metal 16Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
115Venous Return Cannula - single stage -- right angled metal 18Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
116Venous Return Cannula - single stage -- right angled metal 20Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
117Venous Return Cannula - single stage -- right angled metal 22Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
118Venous Return Cannula - single stage -- right angled metal 24Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
119Venous Return Cannula - single stage -- right angled metal26Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
120Venous Return Cannula - single stage -- right angled metal 28Fmultiporttipwithkink resistant wirewoundbody-tip orientation line over all length of at least14 inch long -SPR
121Venous Return Cannula-Cuffedsingle stage - 37F- wirewound bodyat least35 cm longwithinflatable cuff - SPR
122Venousreturn cannula-Two Stageflat body- 28/36F - thin walled - withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
123Venousreturn cannula-Two Stageflat body- 29/29F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
124Venousreturn cannula-Two Stageflat body- 29/37F - thin walled - withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
125Venousreturn cannula-Two Stageflat body- 32/40F - thin walled - withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
126Venousreturn cannula-Two Stageflat body- 36/46F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
127Venousreturn cannula-Two Stageflat body- 34/46F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
128Venousreturn cannula-Two Stageflat body- 36/51F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
129Venousreturn cannula-threeStage -Oval body- 29/29/29 F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
130Venousreturn cannula-threeStage -Oval body- 29/46/37 F - thin walled- withmulti-ported tips& atrial basket - wirewoundwith depth markingswith overall length of at least 38 cm- SPR
131Femoral ArterialPerfusion cannula(Pediatric) - 8F with depth marking, introducer with central lumen - SPR
132Femoral ArterialPerfusion cannula(Pediatric) - 10F with depth marking, introducer with central lumen - SPR
133Femoral ArterialPerfusion cannula(Pediatric) - 12F with depth marking, introducer with central lumen - SPR
134Femoral ArterialPerfusion cannula(Pediatric) - 14F with depth marking, introducer with central lumen - SPR
135Femoral ArterialPerfusion cannula(Adult) - 15F or 16F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
136Femoral ArterialPerfusion cannula(Adult) - 17F or 18F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
137Femoral ArterialPerfusion cannula(Adult) - 19F or 20F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
138Femoral ArterialPerfusion cannula(Adult) - 21F or 22F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
139Femoral ArterialPerfusion cannula(Adult) - 23F or 24F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
140Femoral ArterialPerfusion cannula(Adult) - 25F or 26F - with overalllength of at least 30 cmwith depth marking, introducer,preferably with central lumen & suitable guidewire ( .038“ )and vented connector - SPR
141FemoralVenousPerfusion cannula(Pediatric) - 8F - with Wire wound body,introducer & depth marking & overalllength of at least 19 cm- SPR
142FemoralVenousPerfusion cannula(Pediatric) - 10F - with Wire wound body,introducer & depth marking & overalllength of at least 19 cm- SPR
143FemoralVenousPerfusion cannula(Pediatric) - 12F - with Wire wound body,introducer & depth marking & overalllength of at least 19 cm- SPR
144FemoralVenousPerfusion cannula(Pediatric) - 14F - with Wire wound body,introducer & depth marking & overalllength of at least 19 cm- SPR
145FemoralVenousPerfusion cannula(Adult) -15F-or 16 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
146FemoralVenousPerfusion cannula(Adult) -17F-or 18 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
147FemoralVenousPerfusion cannula(Adult) -19F-or 20 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
148FemoralVenousPerfusion cannula(Adult) -21F-or 22 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
149FemoralVenousPerfusion cannula(Adult) -23F-or 24 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
150FemoralVenousPerfusion cannula(Adult) -25F-or 26 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
151FemoralVenousPerfusion cannula(Adult) -27F-or 28 F with multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
152FemoralVenousPerfusion cannula(Adult) -29 F or 30Fwith multiple side holes, wire wound body, introducer & depth markingpreferably with length of at least 50 cm- SPR
153Cardio-plegic Cannula-Antegrade 3F(18G)with introducer needle, standard tip preferablywith side holes- SPR
154Cardio-plegic Cannula-Antegrade 4Fwith introducer needle, standard tip preferablywith side holes- SPR
155Cardio-plegic Cannula-Antegrade 5F(16G)with introducer needle, standard tip preferablywith side holes- SPR
156Cardio-plegic Cannula-Antegrade 6F or 7F (14G)with introducer needle, standard tip preferablywith side holes- SPR
157Cardio-plegic Cannula-Antegrade 8F or 9F (12G)with introducer needle, standard tip preferablywith side holes- SPR
158Cardio-plegic Cannula-Antegrade 11F with introducer needle, standard tip preferablywith side holes- SPR
159Cardioplegic Cannula-Antegrade with side limb - 4F with introducer needle, standard tip preferablywith side holes and a side limb for venting- SPR
160Cardioplegic Cannula-Antegrade with side limb - 5F (16G) with introducer needle, standard tip preferablywith side holes and a side limb for venting- SPR
161Cardioplegic Cannula-Antegrade with side limb - 6F or 7F(14G)with introducer needle, standard tip preferablywith side holes and a side limb for venting- SPR
162Cardioplegic Cannula-Antegrade with side limb - 8F or 9F (12G)with introducer needle, standard tip preferablywith side holes and a side limb for venting- SPR
163Cardioplegic Cannula-Antegrade with side limb - 11F with introducer needle, standard tip preferablywith side holes and a side limb for venting- SPR
164Cardioplegiacannula-Minimally Invasive Antegrade typewithintroducer needle withstandard tip with a length of at least 30 cm- SPR
165Cardioplegiacannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of12F (4mm)&tip of 2.1 mm-SPR
166Cardioplegiacannula- Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of15F (5mm)&tip of 2.1 mm-SPR
167Cardioplegiacannula - Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of18F (6mm)&tip of 3 mm-SPR
168Cardioplegiacannula -Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of21F (7mm)& tip of 3 mm-SPR
169Cardioplegiacannula -Flexible Left Coronary Ostial straight tip type with soft silicone bulb /balloon of24F (8mm) & tip of 3.5 mm-SPR
170Cardioplegiacannula - Flexible Coronary Ostial right angled type with soft silicone bulb /balloon of12F (4mm)&tip of 2.1 mm-SPR
171Cardioplegiacannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of15F (5mm)&tip of 2.1 mm-SPR
172Cardioplegiacannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of18F (6mm)&tip of 3 mm-SPR
173Cardioplegiacannula - flexible Coronary Ostial right angled type with soft silicone bulb /balloon of21F (7mm)&tip of 3 mm-SPR
174Cardioplegiacannula - Flexible Coronary Ostial right angled type with soft silicone bulb /balloon of24F (8mm)&tip of 3.5 mm-SPR
175Cardioplegiacannula - Flexible Coronary Ostial Tapering typewith soft self-inflating ballooon- tip tapering from 27F (9mm) to 8F (2.7mm) and body encapsulated with malleable wire- SPR
176Cardioplegiacannula -Rigid left Coronary Ostialtype - 45 deg angled basket tip -10F (3.3mm) SPR
177Cardioplegiacannula -Rigid left Coronary Ostialtype - 45 deg angled basket tip - 12F (4mm) SPR
178Cardioplegiacannula -Rigid left Coronary Ostialtype - 45 deg angled basket tip -14F (4.7 mm)- SPR
179Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 deg angled basket tip -10F (3.3mm) SPR
180Cardioplegiacannula -Rigid Right Coronary Ostialtype -80-90 deg angled basket tip - 12F (4mm) SPR
181Cardioplegiacannula -Rigid Right Coronary Ostialtype-80-90 deg angled basket tip -14F (4.7 mm)- SPR
182Retrograde cardioplegia cannula(Coronary sinus) withSolid Stylet 13F -withauto-inflatable cuff& integral stop cock for pressure monitoring - Preferably wirewound body - SPR
183Retrograde cardioplegia cannula(Coronary sinus) withSolid Stylet 15F -withauto-inflatable cuff& integral stop cock for pressure monitoring - Preferably wirewound body - SPR
184Cardiac suction tip- (Mini sucker) soft flexible tapered tip - 9F (3mm) - with angled shaft- SPR
185Cardiac suction tip- (Mini sucker) soft flexible tapered tip - 12F (3mm) - with angled shaft- SPR
186Intra-cardiac suction tip- Rigid - 20F (6.7mm) fluted pool tip- with 16F (5.3mm) - angled metal shaft at least 15 cm long - SPR
187Frazier tip- suction - Small & short6F tip & shaft - about 7.5cm long - SPR
188Frazier tip- suction - Small & long 6F tip & shaft - about 15cm long - SPR
189Frazier tip- suction - Large -10 F tip & shaft - about 10 cm long - SPR
190Intracardiac / pericardial sump suctionType 1:20 Ftip withmetal weighted perforated pooltip& flexible tubingat least 30 cm long - SPR
191Intracardiac / pericardial sump suctionType 2:12 Ftip withmetal weighted perforated pooltip& flexible tubingat least30 cm long - SPR
192Intracardiac / pericardial sump suctionType 3:20 Ftip with spring encased fluted pool tip & flexible tubingat least 30 cm long terminating into a 1/4" connector- SPR
193Left HeartVent Catheter (type 1) PVC tip with malleable body 10F (3.3 mm) with vented connector - SPR
194Left HeartVent Catheter (type 1) PVC tip with malleable body 13F (4.3 mm) with vented connector - SPR
195Left HeartVent Catheter (type 1) PVC tip with malleable body 15F (5 mm) with vented connector - SPR
196Left HeartVent Catheter (type2) Silicone tip with malleable introducer 16F (5.3 mm)- SPR
197Left HeartVent Catheter (type2) Silicone tip with malleable introducer 20F (6.7 mm)- SPR
198Left atrial pressure monitoring catheter - 3F (1mm)= 20 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
199Left atrial pressure monitoring catheter - 4F (1.43mm)= 17 G set of at least 50 cm long with depth markings, attached to a female luer,peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
200Left atrial pressure monitoring catheter - 5F (1.7mm)= 15 G set of at least 50 cm long with depth markings, attached to a female luer,peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
201Disposable Yankur suction cannula with transparentconnecting tube of at least 1 meter long
202Red rubber latex catheters - 8F for vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
203Red rubber latex catheters - 8F for vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
204Red rubber latex catheters - 10F for vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
205Red rubber latex catheters - 12Ffor vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
206Red rubber latex catheters - 14F for vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
207Red rubber latex catheters - 16F for vessel snugging - High quality and tension resistant body - at least 16" longoveral.-SPR
208Vascular tourniquet (Snugger) set Adult (7" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
209Vascular tourniquet (Snugger) set Pediatric (6" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
210Silicone vessel (vascular)loop - Large size sterile medical grade radioopaque silicone loop 2 to 2.5 mm wide ,< 1.2 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors(in each size) - preferablyindiviual loop packed in a separate foil. The cost of a single loop will be takenfor comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
211Silicone vessel (vascular)loop - Small size sterile medical grade radioopaque silicone loop 1 to 1.3 mm wide, < 1 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors(in each size) - preferablyindiviual loop packed in a separate foil. The cost of a single loop will be takenfor comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
212Silicone vessel (vascular)loop - Tinysize sterile medical grade radioopaque silicone loop 0.5 mm wide,< 0.4 mm thick & at least40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors(in each size) - preferablyindiviual loop packed in a separate foil. The cost of a single loop will be takenfor comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
213Air-cushioned- Silicone vessel (vascular) loopwith needle -medical grade siliconeloop with hollow interior for the air-cushion effect - with the maximumdiameter of the loop less than1.3 mm (thickness)andat least25 cm long- SPR
214TemporaryEpi-myocardialPacing wire - Adult type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating astraight cutting needle of at least 60 mm longwith ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 25 to 27 mm tapercut 1/2 circle needle -SPR
215Temporary Epi-myocardial Pacing wire - Pediatric type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating astraight cutting needle of at least 60 mm longwith ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 16 to 18 mm tapercut 1/2 circle needle -SPR
216Sternalclosure polymer bands Sterile bands (of less than 5 mm width) made of biocompatible & MRI compatible poly-ether-ether-ketone polymer substance in a pack of 5 bands - These bands must be amenablefor being cut open with standardwire cutters in case of sternal re-entry procedures.
217Coronaryshunts(silicon type) 1 mmm- for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with14 mm long & clear shaft. SPR
218Coronaryshunts(silicon type) 1.25 mmm- for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with14 mm long & clear shaft. SPR
219Coronaryshunts(silicon type) 1.5 mmm- for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with14 mm long & clear shaft. SPR
220Coronaryshunts(silicon type) 1.75 mmm- for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with14 mm long & clear shaft. SPR
221Coronaryshunts(silicon type) 2 mm- for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with14 mm long & clear shaft. SPR
222Disposable Aortic -Vascular Punch 2.5 to 2.8 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
223Disposable Aortic -Vascular Punch 3 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
224Disposable Aortic -Vascular Punch 3.5 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
225Disposable Aortic -Vascular Punch 4 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
226Angled Disposable Bull Dog Type Vascular clamp-Type Awith clamping pressure of 10-15Gusedfor CABG.. Should be radiopaque & light weight with atraumatic jaw types- SPR .
227Angled Disposable Bull Dog Type Vascular clamp-Type Bwith clamping pressure of 20-25Gusedfor CABG.. Should be radiopaque & light weight with atraumatic jaw types- SPR .
228Angled Disposable Bull Dog Type Vascular clamp-Type Cwith clamping pressure of 75-80Gusedfor CABG.. Should be radiopaque & light weight with atraumatic jaw types- SPR .
229Angled Disposable Bull Dog Type Vascular clamp-Type Dwith clamping pressure of 165-175Gusedfor CABG.. Should be radiopaque & light weight with atraumatic jaw types- SPR .
230Suction based Cardiac Stabilizer -Retracting arm unit type (Octopus like) for OPCAB (off pump coronary artery bypass).The retracting arms unit should have surgeon controlled pod-spread, allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications, one-handed engagement of clamp and turret assembly.
231Suction based Cardiac Stabilizer - Apex positioner (Starfish like) for OPCAB (off pump coronary artery bypass).Should enhance lifting the apex of the heart and fixing to any positon.
232Mist blowing device for OPCAB (off pump coronary artery bypass). With fluid/gas mixing technology creating a consistent, predictable blood clearing mist. On/off control in hand-piece - Malleable shaft - Specialized nozzle, utilizing a micro-orifice for fluid delivery and a separate orifice for gas delivery- SPR
233Vessel cannula - 3 mm tip -with stepped contour - transparent body & a female luer at one endfor checking the patency and leak in the harvestedgrafts - length about 5 cm SPR. transparent body & a female luer at one endfor checking the patency and leak in the harvestedgrafts - length about 5 cm SPR.
234Vessel cannula - 2 mm tip -with stepped contour - transparent body & a female luer at one endfor checking the patency and leak in the harvestedgrafts - length about 5 cm SPR. transparent body & a female luer at one endfor checking the patency and leak in the harvestedgrafts - length about 5 cm SPR.
235IMA (Internal Mammary Arterial) cannula -1mm - with bulb shaped tip for checking patency of the artery
236Arteriotomy cannula -2 mm with polyurethane tube with a bulb shaped tip connected to a winged female luerabout 5 cmlong - SPR
237Custom madeElastic Stockings for lower limbs with suitableapplier- made up of a mix of cotton, polyamide & elastane. (Quote only the price of a single stocking not of a pair) for patients after venous harvest or with varicose veins - SPR
238Valves General Instructions The valves have to be supplied on consignment basis such that- a stock of one valve in each size should be made available in the user area (CTVS-OT) and after the utilization of a valve of particular size, the same has to be replaced to fill the stock by the firm who supplied the valve. The infromation ofutilization of the valve has tobe conveyed to the supplier by the storekeeper who inturn will be informed by the SNO of CTVS OT.
239Tilting Disc Aortic valve 18/19 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
240Tilting Disc Aortic valve 20/21 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
241Tilting Disc Aortic valve 22/23 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
242Tilting Disc Aortic valve 24/25 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
243Tilting Disc Mitralvalve 25/26 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
244Tilting Disc Mitralvalve 27/28 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
245Tilting Disc Mitralvalve 29/30 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
246Tilting Disc Mitralvalve 31/32 mm. The valve should be rotatable after seating. Valve to be supplied with the suitable holder.Two sets ofvalve sizer & valve testerhave to be suppied with suitable trays(irrespective of the number of valves purchased) for the year
247BileafletAorticvalve 16/17 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
248BileafletAorticvalve 18/19 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
249BileafletAorticvalve 20/21 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
250BileafletAorticvalve 22/23 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
251BileafletAorticvalve 24/25 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
252BileafletAorticvalve 26/27 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
253Bileaflet Mitralvalve 16/17 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
254BileafletMitralvalve 18/19 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
255BileafletMitral valve 20/21 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
256BileafletMitral valve 22/23 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
257BileafletMitralvalve 24/25 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
258BileafletMitralvalve 26/27 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
259BileafletMitralvalve 28/29 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
260BileafletMitralvalve 30/31 mm To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve.Purchase will be made individually whenever necessary on SOS basis (Consignment mode).
261Bovinepericardial stented bioprosthetic aortic valve19/20mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
262Bovinepericardial stented bioprosthetic aortic valve 21/22 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter.To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
263Bovinepericardial stented bioprosthetic aortic valve 23/24 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base. With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
264Bovinepericardial stented bioprosthetic aortic valve 25/26 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base. With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
265Bovinepericardial stented bioprosthetic aortic valve27/28 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
266Bovinepericardial stented bioprosthetic aortic valve29/30mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
267Bovinepericardial stented bioprosthetic Mitralvalve25/26 mm of theLatest generation technology of the quoted brand with lowprofile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
268Bovinepericardial stented bioprosthetic Mitralvalve 27/28 mm of theLatest generation technology of the quoted brand with lowprofile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
269Bovinepericardial stented bioprosthetic Mitralvalve29/30 mm of theLatest generation technology of the quoted brand with lowprofile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
270Bovinepericardial stented bioprosthetic Mitralvalve31/32 mm of theLatest generation technology of the quoted brand with lowprofile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
271Bovinepericardial stented bioprosthetic Mitralvalve 33/34 mm of theLatest generation technology of the quoted brand with lowprofile supra-annular fit valve with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
272Porcine stented bioprosthetic aortic valve 19/20mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
273Porcine stented bioprosthetic aortic valve 21/22 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
274Porcinestented bioprosthetic aortic valve 23/24 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
275Porcine stented bioprosthetic aortic valve 25/26 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
276Porcinestented bioprosthetic aortic valve27/28 mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
277Porcine stented bioprosthetic aortic valve29/30mm of theLatest generation technology of the quoted brand with lowestprofile height& loweststent base.With suture markers& contoured and compliant sewing ringwith the smallest possible diameter. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
278Porcine stented bioprosthetic Mitralvalve25/26 mm of theLatest generation technology of the quoted brand with lowprofilewith asymmetric design to position the posterior strut away from LV wall.To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
279Porcine stented bioprosthetic Mitralvalve27/28 mm of theLatest generation technology of the quoted brand with lowprofilewith asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
280Porcine stented bioprosthetic Mitralvalve29/30 mm of theLatest generation technology of the quoted brand with lowprofilewith asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
281Porcine stented bioprosthetic Mitralvalve31/32 mm of theLatest generation technology of the quoted brand with lowprofilewith asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
282Porcine stented bioprosthetic Mitralvalve33/34 mm of theLatest generation technology of the quoted brand with lowprofilewith asymmetric design to position the posterior strut away from LV wall.To be supplied with holder & sizer set.Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
283Stentless bioprosthetic conduit aortic root with valve - 19/20 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
284Stentless bioprosthetic conduit aortic root with valve - 21/22 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
285Stentless bioprosthetic conduit aortic root with valve - 23/24 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
286Stentless bioprosthetic conduit aortic root with valve - 25/26 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
287Stentless bioprosthetic conduit aortic root with valve - 27/28 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
288Stentless bioprosthetic conduit aortic root with valve - 29/30 mmfor Bentall Operation. To be supplied with holder & sizer set. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
289Bioprostheticvalved conduit (bovine jugular) for Right ventricular to pulmonary arterialconduit.Valve size : 12/13 mm. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
290Bioprostheticvalved conduit (bovine jugular) for Right ventricular to pulmonary arterialconduit.Valve size : 14/15 mm. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
291Bioprostheticvalved conduit (bovine jugular) for Right ventricular to pulmonary arterialconduit. Valve size : 16/17 mm. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
292Bioprostheticvalved conduit (bovine jugular) for Right ventricular to pulmonary arterialconduit. Valve size : 18/19 mm. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
293Bioprostheticvalved conduit (bovine jugular) for Right ventricular to pulmonary arterialconduit.Valve size : 20/21 mm. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)
294ProstheticComposite Aortic Valved Conduitswith valve size 18/19 mmforBental operation. Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
295ProstheticComposite Aortic Valved Conduitswith valve size 20/21 mmforBental operation. Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
296ProstheticComposite Aortic Valved Conduitswith valve size 22/23 mmforBental operation.Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S. on consignment basis(i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) .Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
297ProstheticComposite Aortic Valved Conduitswith valve size 24/25mmforBental operation.Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) .Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
298ProstheticComposite Aortic Valved Conduitswith valve size 26/27 mmforBental operation. Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
299ProstheticComposite Aortic Valved Conduitswith valve size 28/29 mmforBental operation.Should beincorporated withprosthetic bileaflet valvemounted on to collagenimpregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) .Only 1 number in each size will be in the shelfand purchased as a set during teh first purchase - as a stock for emergency
300Ophthalmic cautery- sterile , disposable & battery operated for making perfect holes in the prosthetic vascular grafts
301Annuloplasty complete ring for mitral valve. Size : 23/24 mm Near anatomical contour withasymmetric remodelling design. Should be supplied with suitableholder & sizer.Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
302Annuloplasty complete ring for mitral valve. Size : 25/26 mm Near anatomical contour withasymmetric remodelling design.Should be supplied with suitableholder & sizer. Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
303Annuloplasty complete ring for mitral valve. Size : 27/28 mm Near anatomical contour withasymmetric remodelling design.Should be supplied with suitableholder & sizer. Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
304Annuloplasty complete ring for mitral valve. Size : 29/30 mm Near anatomical contour withasymmetric remodelling design. Should be supplied with suitableholder & sizer.Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
305Annuloplasty complete ring for mitral valve. Size : 31/32 mm Near anatomical contour withasymmetric remodelling design.Should be supplied with suitableholder & sizer. Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
306Annuloplasty complete ring for mitral valve. Size : 33/34 mm Near anatomical contour withasymmetric remodelling design.Should be supplied with suitableholder & sizer.Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
307Annuloplasty complete ring for mitral valve. Size : 35/36 mm Near anatomical contour withasymmetric remodelling design.Should be supplied with suitableholder & sizer. Purchase will be made individually whenever necessary -S.O.S.on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) . A set of one number in each size will be purchase at first and remain in the shelffor emergency.
308Annuloplastyring for Tricuspid valveincompletering type - (largest inner diameter being:25/26 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitableholder & sizer . Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
309Annuloplastyring for Tricuspid valveincompletering type - (largest inner diameter being:27/28 mm. Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer .Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
310Annuloplastyring for Tricuspid valveincompletering type- (largest inner diameter being: 29/30 mm.Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer . Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
311Annuloplastyring for Tricuspid valveincompletering type- (largest inner diameter being:31/32mm.Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer . Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
312Annuloplastyring for Tricuspid valveincompletering type - (largest inner diameter being: 33/34 mm. Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer .Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelffor emergency.
313Annuloplastyring for Tricuspid valveincompletering type - (largest inner diameter being:35/36 mm.Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer . Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelffor emergency.
314Annuloplastyring for Tricuspid valveincompletering type- (largest inner diameter being: 37/38 mm.Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer .Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
315Annuloplastyring for Tricuspid valveincompletering type - (largest inner diameter being:39/40 mm. Near anatomical contour with downward angle at septal end.Should be supplied with suitableholder & sizer .Purchase will be made individually whenever necessary -S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned)A set of one number in each size will be purchase at first and remain in the shelffor emergency.
316Suture guide /Suture-grip /Suture-organizer of Gabbay Fratermechanism for heartvlave operationsCurved profile with capacity to hold at least 8 paired sutureswith positional numbering labelled in a guide with fixation ports. Each sterile pack should contain3 such guides.
317Arterial embolectomy caztheter 2F x 60 cm - enclosed in a rigid case - SPR
318Arterial embolectomy caztheter 3F x 80 cm - enclosed in a rigid case - SPR
319Arterial embolectomy caztheter 5F x 80 cm - enclosed in a rigid case - SPR
320Arterial embolectomy caztheter 7F x 80 cm - enclosed in a rigid case - SPR
321PTFE vascular tube grafts 3 mm -at least 10 cm long(peferably thin walled)
322PTFE vascular tube grafts 3.5 mm -at least 10 cm long (peferably thin walled)
323PTFE vascular tube grafts 4 mm -at least 10 cm long (peferably thin walled)
324PTFE vascular tube grafts 4.5 mm-at least 10 cm long(peferably thin walled)
325PTFE vascular tube grafts 5 mm-at least 10 cm long (peferably thin walled)
326PTFE vascular tube grafts 6 mm -at least 10 cm long
327PTFE vascular tube grafts 7 mm -at least 10 cm long
328PTFE vascular tube grafts 8 mm-at least 10 cm long
329PTFE vascular tube grafts 6 mm-at least 30 cm long
330PTFE vascular tube grafts 7 mm-at least 30 cm long
331PTFE vascular tube grafts 8 mm -at least 30 cm long
332PTFE vascular tube grafts 12 mm-at least 30 cm long
333PTFE vascular tube grafts 14 mm -at least 30 cm long
334PTFE vascular tube grafts 16 mm-at least 30 cm long
335PTFE vascular tube grafts 18 mm-at least 30 cm long
336PTFE vascular tube grafts 20 mm -at least 30 cm long
337PTFE vascular tube grafts 22 mm -at least 30 cm long
338PTFE vascular tube grafts 24 mm -at least 30 cm long
339PTFE vascular tube grafts 5 mm -at least50cm long
340PTFE vascular tube grafts 6 mm -at least50cm long
341PTFE vascular tube grafts 7 mm -at least50cm long
342PTFE vascular tube grafts 8 mm-at least50cm long
343PTFE vascular tube grafts - with external support (ringed) 6 mm - at least 70cm long
344PTFE vascular tube grafts - with external support (ringed) 7 mm - at least 70cm long
345PTFE vascular tube grafts - with external support (ringed) 8 mm - at least 70cm long
346Axillo-bifemoralPTFE vascular tube grafts- 8 mm diameter & length of 90 cm plus50 cm. Purchase will be made individually whenever necessary -S.O.S.
347Cuffed ePTFE graft with trim line of 4-6 mmx 60 cm- for ananstamosis with the small recepient vessel of size -3mm & less. Preferably within-built antiplatelet / antithrombotic mechanism.
348Cuffed ePTFE graft with trim line of 4-6 mmx 90 cm- for ananstamosis with the small recepient vessel of size -3mm & less. Preferably within-built antiplatelet / antithrombotic mechanism.
349AV accessePTFE graft-6mm x 40 cm designed specially forforcreating AV fistual creation for hemodialysis. The graft should be able to withstand multiple needle punctures without bleeding after the needle is removed.
350Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 6 mm
351Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 7 mm
352Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 8 mm
353Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 10 mm
354Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 12 mm
355Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 14 mm
356Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 16 mm
357Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 18 mm
358Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia:20 mm
359Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 22 mm
360Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 24 mm
361Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 26 mm
362Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 28 mm
363Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 30 mm
364Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 32 mm
365Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 34 mm
366Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 15 cm long - Dia: 36 mm
367Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
368Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 7 mm
369Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 8 mm
370Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 10 mm
371Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 12 mm
372Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 14 mm
373Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 16 mm
374Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 18 mm
375Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 20 mm
376Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 22 mm
377Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 24 mm
378Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 26 mm
379Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 28 mm
380Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 30 mm
381Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 32 mm
382Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 34 mm
383Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 36 mm
384Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
385Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 30 cm long - Dia: 6 mm
386Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 6 mm
387Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 7 mm
388Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 8 mm
389Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 10 mm
390Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 12 mm
391Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 14 mm
392Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 16 mm
393Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 18 mm
394Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 20 mm
395Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 22 mm
396Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 24 mm
397Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 26 mm
398Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 28 mm
399Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 60 cm long - Dia: 30 mm
400Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 6 mm
401Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 7 mm
402Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 10 mm
403Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 12 mm
404Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 14 mm
405Collagen ImpregnatedPolyester Straight Tube grafts with crimps - 90 cm long - Dia: 16 mm
406Collagen Impregnated -WovenPolyesterBifurcatedTube grafts (with Y limbs) with crimps - 40to 50 cm longand size (diameter) of limbs : 12 mm x 6 mm
407Collagen Impregnated -WovenPolyesterBifurcatedTube grafts (with Y limbs) with crimps - 40to 50 cm longand size (diameter) of limbs : 14 mm x 7 mm
408Collagen Impregnated -WovenPolyesterBifurcatedTube grafts (with Y limbs) with crimps - 40to 50 cm longand size (diameter) of limbs : 16 mm x 8 mm
409Collagen Impregnated -WovenPolyesterBifurcatedTube grafts (with Y limbs) with crimps - 40to 50 cm longand size (diameter) of limbs : 18 mm x 9 mm
410Collagen Impregnated -WovenPolyesterBifurcatedTube grafts (with Y limbs) with crimps - 40to 50 cm longand size (diameter) of limbs : 20 mm x 10 mm
411Polyester fiber suture / ligature5 mm x at least 40 cm (for Pulmonary arterialbanding) SPR
412ePTFE Sutures for valve repairsDouble armed –90 cm with Taper point 3/8 circle needles –preferably with needle to suture rationearer to or equivalent to 1:1. in terms of tensile strength suture :the size : 4-0(Cost of each foil has to be quoted,In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
413ePTFE Sutures for valve repairsDouble armed –90 cm with Taper point 3/8 circle needles –preferably with needle to suture rationearer to or equivalent to 1:1. in terms of tensile strength suture :the size : 5-0(Cost of each foil has to be quoted,In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
414ePTFE Sutures for valve repairsDouble armed –90 cm with Taper point 3/8 circle needles –preferably with needle to suture rationearer to or equivalent to 1:1. in terms of tensile strength suture :the size : 6-0(Cost of each foil has to be quoted,In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
415Polybutester suture With polytribolate coating with the property of needle hole self-sealing for vascular anastamoses. Size 7-0 x 60 cm with 3"/8 circle8mm needle (Cost of each foil has to be quoted,In case of quoting the cost for a box, the no.of suture fooils in each box should be mentioned)
416Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 5cmx 10 cmPreferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
417Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 10cmx 10 cmPreferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
418Polyester patch - Type A (Woven fabric) - 0.25 mm thick. - 15cmx 15 cmPreferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
419Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 6 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
420Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 8 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
421Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 8 mm x 152 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
422Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 25 mm x 76 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
423Polyester patch - Type B (Woven fabric) - 0.36 mm thick. 25 mm x 152 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
424Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 25 mm x 50 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
425Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 25 mm x 100 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
426Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 50 mm x 50 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
427Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 75 mm x 75 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
428Polyester patch - Type C (Woven fabric) - 0.44 mm thick. 100 mm x 100 mm- Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
429Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:6 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
430Polyester patch - Type D(Woven fabric) - 0.61 - 0.65 mm thick - Size:10 mm x 140 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
431Polyester patch - Type D(Woven fabric) - 0.61 - 0.65 mm thick - Size:20mm x 140mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
432Polyester patch - TypeD (Woven fabric) - 0.61 - 0.65 mm thick - Size:25mm x 50 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
433Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:25 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
434Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:25 mm x 100 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
435Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:25 mm x 150 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
436Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:50 mm x 50 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
437Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:50 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
438Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:50 mm x 150 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
439Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:75 mm x 75 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
440Polyester patch - Type D (Woven fabric) - 0.61 - 0.65 mm thick - Size:100 mm x 100 mm- The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
441Polyester patch - Type E(Double velour- Woven fabric)- 0.46 mm thick-Size :25mmx 152 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
442Polyester patch - Type E(Double velour- Woven fabric)- 0.46 mm thick-Size :51mmx 76 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
443Polyester patch - Type E(Double velour- Woven fabric)- 0.46 mm thick-Size :51mmx 152 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
444Polyester patch - Type F(Double velour- knitted fabric)- 0.76 mm thick.Size: 6 mm x 76 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
445Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 6 mm x 122 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
446Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 8 mm x 76 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
447Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 8 mm x 152 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
448Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 25 mm x 76 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
449Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 25 mm x 152 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
450Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 50 mm x 15 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
451Polyester patch - Type F(Double velour- knitted fabric)- 0.76 mm thick.Size: 60 mm x 30 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
452Polyester patch - Type F(Double velour- knitted fabric)- 0.76 mm thick.Size: 70 mm x 15 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
453Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 80 mm x 40 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
454Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 100 mm x 15 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
455Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 120 mm x 40 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
456Polyester patch - Type F (Double velour- knitted fabric)- 0.76 mm thick.Size: 120 mm x 80 mm.Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
457Polyester patch - Type G (Double velour- knitted fabric)-1.5 mm thick - 25 mm x 50 mm as used for closure oflarge VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
458Polyester patch - Type G(Double velour- knitted fabric)-1.5 mm thick - 25 mm x 100 mm as used for closure oflarge VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
459Polyester patch - Type G (Double velour- knitted fabric)-1.5 mm thick - 50 mm x 50 mm as used for closure oflarge VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
460Polyester patch - Type G (Double velour- knitted fabric)-1.5 mm thick - 50 mm x 100 mm as used for closure oflarge VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
461Polyester patch - Type G (Double velour- knitted fabric)-1.5 mm thick -100 mm x 100 mm as used for closure oflarge VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
462PET (polyethylene Pteriphthalate) patch about8 mm x 75 mm -aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
463PET (polyethylene Pteriphthalate) patch about25 mm x 76 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
464PET (polyethylene Pteriphthalate) patch about 25 mm x 152mm -aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
465PET (polyethylene Pteriphthalate) patch about 50 mm x 76 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
466PET (polyethylene Pteriphthalate) patch about 50 mm x 152 mm -aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
467ePTFETrilaminar patch - Type A. (0.3 mm thick) - 20 mm x 30 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
468ePTFETrilaminar patch - Type A. (0.3 mm thick) - 20 mm x 75 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
469ePTFETrilaminar patch - Type A. (0.3 mm thick) - 15 mm x 20 mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
470ePTFETrilaminar patch - Type A. (0.3 mm thick) - 8 mm x 30 mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
471ePTFETrilaminar patch - Type A. (0.3 mm thick) -6 mm x 75mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
472ePTFETrilaminar patch - Type A. (0.3 mm thick) -8 mm x 75mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
473ePTFETrilaminar patch - Type A. (0.3 mm thick) -10 mm x 75mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
474ePTFETrilaminar patch - Type A. (0.3 mm thick) -20 mm x 90mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
475ePTFETrilaminar patch - Type B. (0.5 mm thick) -8mm x 75mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
476ePTFETrilaminar patch - Type B. (0.5 mm thick) -10 mm x 90 mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
477ePTFETrilaminar patch - Type B. (0.5 mm thick) - 25mm x 150mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
478ePTFETrilaminar patch - Type B. (0.5 mm thick) - 30mm x 30mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
479ePTFETrilaminar patch - Type B. (0.5 mm thick) - 30mm x 60mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
480ePTFETrilaminar patch - Type B. (0.5 mm thick) - 50mm x 75mmMade up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
481ePTFE patch - Type C(0.4 mm thick) - 10 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
482ePTFE patch - Type C (0.4 mm thick) - 20 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
483ePTFE patch - Type C (0.4 mm thick) - 30 mm x 60 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
484ePTFE patch - Type D(0.58to 0.62 mm thick) 30 mm x 30 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
485ePTFE patch - Type D(0.58to 0.62 mm thick) 50 mm x 75 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
486ePTFE patch - Type D (0.58to 0.62 mm thick)25 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
487ePTFE patch - Type D (0.58to 0.62 mm thick) 50 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
488ePTFE patch - Type D(0.58to 0.62 mm thick) 100 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
489PTFE patch (0.9 mm thick)50 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
490PTFE patch (0.9 mm thick)100 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
491PTFE patch (0.9 mm thick)150 mm x150 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
492Polyester Felt1.65 mm thick -150mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
493PTFE Felts- 1.65 mm thick 12 mm x 100 mm
494PTFE Felts- 1.65 mm thick25 mm x 25 mm
495PTFE Felts- 1.65 mm thick25 mm x 100 mm
496PTFE Felts- 1.65 mm thick 25 mm x 150 mm
497PTFE Felts- 1.65 mm thick 50 mm x 50 mm
498PTFE Felts- 1.65 mm thick100 mm x 100 mm
499PTFE Felts- 1.65 mm thick150 mm x 150 mm
500PTFE Felt with low porosity - 1.85 mm thick - 25 mm x 25 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
501PTFE Felt with low porosity -1.85 mm thick - 100 mmx 100 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
502PTFE Felt with low porosity -1.85 mm thick - 150mm x150 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
503Tissue engineered pericardial patch4 cm x 4cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic,flexible & ultrathin (2 to 5mm thick)with goodsuturabilitywith at least 1 year shelf life.
504Tissue engineered pericardial patch6 cm x 6 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic,flexible & ultrathin (2 to 5mm thick)with goodsuturabilitywith at least 1 year shelf life.
505Tissue engineered pericardial patch8 cm x 8cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic,flexible & ultrathin (2 to 5mm thick)with goodsuturabilitywith at least 1 year shelf life.
506Tissue engineered pericardial patch10cm x 10 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic,flexible & ultrathin (2 to 5mm thick)with goodsuturabilitywith at least 1 year shelf life.
507PTFEpledgets Thickness x breadth & length : 0.5mm x 3 mm x 3 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
508PTFEpledgets Thickness x breadth & length : 1 mm x 3 mm x 3 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
509PTFEpledgetsThickness x breadth & length :1 mm x 3 mm x 6 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
510PTFEpledgets Thickness x breadth & length : 1.5mm x 3 mm x 3 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
511PTFEpledgetsThickness x breadth & length : 1.5mm x 3 mm x 6 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
512PTFE FELTpledgetsThickness x breadth & length : 1.65 mm x 4.8mm x 6 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
513PTFEFELT pledgets Thickness x breadth & length :1.65 mm x 6 mm x 6 mm For vascular and cardiac sutures -Specify the number of pledgets in a pack and the rate of the pack clearly.SPR
514Topical hemostatic : Fibrinogen- human thrombin- aprotinin -in prefilled syringes applicatorwith atotal volume of10 ml in a pack. SPR
515Topical hemostatic : Polythylene glycol - 4 mlfor raw surfaces oflung for hemostatic and also for preventing air leak and alsopreventive usage incardiac / vascularsuture lines
516Topical hemostatic- Albumin gluter-aldehyde glue -Total volume of 10ml per packcontained in the prefilled syringes andforming a strongbut flexiblelayer of seal- compatible to fix the separated layers of dissected aorta. To be provided with suitable applicator for focused local application.
517Topical bio-absorbable hemostatic: Non-oxidativecellulose 5 x 5 cm - hemostatic acting by non--oxidative chemical reaction using cellulose asa substance.
518Trachealstents (fully covered) - Straight type. Should have radioopaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode)in which case, a set of various sizes of stentsto be brought on the day of procedure and after the usage the rest of thestents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient"s condition
519Trachealstents (fully covered) - Bifurcated Y typeShould have radioopaque markers at all the three ends. The purchase will be done as when needed on SOS basis (Consignment mode)in which case, a set of various sizes of stentsto be brought on the day of procedure and after the usage the rest of thestents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient"s condition
520Bronchial stents (fully covered) - Straight type. Should have radioopaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode)in which case, a set of various sizes of stentsto be brought on the day of procedure and after the usage the rest of thestents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient"s condition
521Guidewire for deployingthe tracheal stent - the selection will be based on the compatibility wit the brand selected for the Tracheal stent .
522Thoracic aortic stent grafts - Straight type :To be supplied with the suitable delivery system with smallest possible catheter outer diameter.The stent should be MRI compatible. The purchase will be done as when needed,in which case, a set of various sizes of stentsto be brought on the day of surgery and after the usage the rest of thestents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting.(Size ordered will be based on the patient"s condition)
523Thoracic aortic stent grafts - Bifurcated Y type :To be supplied with the suitable delivery system with smallest possible catheter outer diameter.The stent should be MRI compatible. The purchase will be done as when needed,in which case, a set of various sizes of stentsto be brought on the day of surgery and after the usage the rest of thestents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting.(Size ordered will be based on the patient"s condition)
524Sterile Guidewire suitable to fit 16G needle - for Seldinger technique - with minimum length of 50 cm - SPR
525Sterile Guidewire suitable to fit 18G needle - for Seldinger technique - with minimum length of 50 cm - SPR
526Sterile Guidewire suitable to fit 20G needle - for Seldinger technique - with minimum length of 50 cm - SPR
527Sterile Guidewire suitable to fit 22G needle - for Seldinger technique - with minimum length of 50 cm - SPR
528Sterile Guidewire - 0.038 inchfor femoral vessel cannulation
529Femoral puncture needle - 16G - for Seldinger technique - at least 180 -200 cm long.SPR.
530CABG drape kit with9 components: (Totally15+1parts in a pack)Go through the link for detailed specifications: https://docs.google.com/document/d/1yOTEiRccpX3apBvgbX438OyfICTzx77sPLQ3Xk4ZapA/edit
531General open heart drape kit containing the following components.(Totally10+1parts in a pack)Go through the link for detailed specifications:https://docs.google.com/document/d/1_H3eESdoj0TiCagChls5BVnMXGQfF3lW9PTyPavhcKE/edit?usp=sharing
532SternalWound Dressing Pad - Sterileadhesive polyurethane film with absorbent pad, 20 x 10 cm - SPR
533Montogomer T-type Silicon tracheostomy tube - SPR
534Double lumen endotracheal tube(DLET) - Left sided-26FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
535Double lumen endotracheal tube(DLET) - Left sided-28FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
536Double lumen endotracheal tube(DLET) - Left sided-32FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
537Double lumen endotracheal tube(DLET) - Left sided-35FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
538Double lumen endotracheal tube(DLET) - Left sided-37FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
539Double lumen endotracheal tube(DLET) - Left sided-39FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
540Double lumen endotracheal tube(DLET) - Left sided-41FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
541Double lumen endotracheal tube(DLET) - Right sided-26FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
542Double lumen endotracheal tube(DLET) - Right sided-28FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
543Double lumen endotracheal tube(DLET) - Right sided-32FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
544Double lumen endotracheal tube(DLET) - Right sided-35FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
545Double lumen endotracheal tube(DLET) -Rightsided-37FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
546Double lumen endotracheal tube(DLET) - Rightsided-39FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
547Double lumen endotracheal tube(DLET) -Rightsided-41FTransparent Double lumen cuffed endobronchialtubehaving smooth gliding surface radioopaque line & sensitive pilot balloons with separate color coding for bronchial and tracheal lumens and balloons.(SPR for for any one size)
548Endo-bronchial blockers - withballoon - Ardnt type - For one lung ventilation - Wire loopguide and suitable adapterforbronchoscope.
549Endo-bronchial blockers - withballoon -Cohentype - For one lung ventilationwith flexible defelcting tip with suitable adapter to faciltate bronchoscope.
550Endo-bronchial blockers - withballoons -EZtype - with Y-tipped For one lung ventilation
551Ultrasonic Nebulizer -SPR fordemostration. Or product catalogue brochure with figure to be submitted.
552Soft vinyl percussors for performing chest physiotherapy indifferent sizes
553Electro Surgical(cautery) pencils - (electrosurgical electrode) with Long arm- Spatula tip &hand control oftwin switch type for cutting and coagulation modes-Should be Compatible with Martin & AlanCautery (electrosurgical)machines. Prefererable dimensions:shaft diameter less than 2.5 mm. Shaft length -130-140 mm Spatula dimension - about 20 x 2.5 x 0.5 mm Appropraite certification for electrical safety should be confirmed. - SPR
554Disposable Microscalpel withhigh qualitymicro-blade attached for coronary arteriotomy - SPR
555Sterile cover for Echocardio-graphicprobeFor use in the operative -field. Should fit universally all utrasound probes commonly used during cardiac surgery with special fold to accomdatethe probe end without wrinkles. Should be made up of clear transparent latex free medical grade material - polythene.Length of cover - 150 cm;Width of the cover - 10 cm. The kit should also contain securing tapes to hold the cover around the probe and preferably with ultrasound transmission gel - pack.
556NON-CONSUMABLES
557De bakeyStraightFineVascularForceps - Short (18cm) jaw (1.5 x 14mm)5mm wide shaft
558De bakey StraightFineVascularForceps - Medium (25cm) jaw (1.5 x 14mm) 5mm wide shaft
559De bakeyStraightFineVascularForceps - Long (30cm)jaw (1.5 x 14mm) 5mm wide shaft
560De bakey Angled 45º FineVascular Fine Forceps - Short (18cm)with smooth jaw (1.5 x 14 mm)&5mm wide shaft - for IMA dissection
561De bakey Angled 45º FineVascular Forceps - - Medium(25 cm )with smooth jaw (1.5 x 14 mm)&5mm wide shaft - for IMA dissection
562De bakeyAngled 45ºFine Forceps Vascular - Long (30 cm)with smooth jaw (1.5 x 14 mm)&5mm wide shaft - for IMA dissection
563De bakeyDouble ActionStraightFineVascularForceps - Short (18cm)- with 1x2 teeth - jaw (1.5 x 10mm)4-5mm wide shaft
564De bakeyDouble ActionStraightFineVascularForceps - Medium (25cm)- with 1x2 teeth -jaw (1.5 x 10mm)4-5mm wide shaft
565De bakeyDouble ActionStraightFineVascularForceps - Long (30cm)- with 1x2 teeth - jaw (1.5 x 10mm)4-5mm wide shaft
566De bakeyDouble ActionStraightVascularForceps - Short (18cm) with 1x2 teeth- jaw (2.5-2.8x 12mm)4-6mm wide shaft
567De bakeyDouble ActionStraightVascularForceps - Medium (25cm) with 1x2 teeth- jaw (2.5-2.8x 12mm)4-6mm wide shaft
568De bakeyDouble ActionStraight VascularForceps - Long (30cm) with 1x2 teeth- jaw (2.5-2.8x 12mm)4-6mm wide shaft
569De bakeyDouble ActionStraightTissueForceps - Short (18cm)with 1x2 teeth- jaw ( 3 x 14 mm) 4-6mm wide shaft
570De bakeyDouble ActionStraightTissue Forceps - Medium (25cm) with 1x2 teeth- jaw (3 x14mm) 4-6mm wide shaft
571De bakeyDouble ActionStraight TissueForceps - Long (30cm) with 1x2 teeth- jaw (3 x 14 mm)4-6mm wide shaft
572De bakeyDouble ActionExtra-large StraightTissueForceps - Short (18cm) with3 x2 teeth - jaw ( 5 x 28mm) 4-6mm wide shaft
573De bakeyDouble ActionExtra-large StraightTissueForceps - Medium(25 cm) with3 x2 teeth- jaw ( 5 x 28mm) 4-6mm wide shaft
574De bakeyDouble ActionExtra-large StraightTissueForceps - Long (30cm) with3 x2 teeth - jaw ( 5 x 28mm) 4-6mm wide shaft
575Resano Atruamatic Forceps - Short (18 cm)- Straight jaws-2.5 -3 mm x 14 mm &4-6 mm wide shaft.
576Resano Atruamatic Forceps - Medium (25 cm)- Straight jaws-2.5 -3 mm x 14 mm & 4-6 mm wide shaft.
577Resano Atruamatic Forceps - long(30 cm)- Straight jaws-2.5 -3 mm x 14 mm &4-6 mm wide shaft.
578Resano Atruamatic Double action Forceps-Short (18 cm)- Straight jaws-14 mm & 4-6 mm wide shaft.
579Resano AtruamaticDouble action Forceps-Medium(25 cm)-Straight jaws-14 mm &4-6 mm wide shaft.
580Resano Atruamatic Double action Forceps-Long (30 cm)- Straight jaws14 mm &4-6 mm wide shaft.
581Resano Atruamatic Double action LargeForceps-Short (18 cm)-Straight jaws-18 mm & 4-6 mm wide shaft.
582Resano Atruamatic Double action Large Forceps-Medium(25 cm)-Straight jaws18 mm &4-6 mm wide shaft.
583Resano Atruamatic Double action Large Forceps-Long (30 cm)-Straight jaws-18 mm & 4-6 mm wide shaft.
584Gemini Double Action Diliating, Curved, Smooth Forceps(31-37 cmlong)with 1 x 2 teeth, Jaw length - 30 mm,Shaft dia 4-6 mm
585Rongeur for Valve - 30º Curved Tip (31-37 cm long)Jaw size - 3.5 mmShaft dia: 4-6 mm
586Rongeur for Valve - StraightTip (31-37 cm long)Jaw size - 3.5 mm Shaft dia : 4-6 mm
587Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 120 mm- ( 2 x 3 Teeth)
588Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 90 mm- ( 2 x 3 Teeth)
589Debakey -Chitwood Aortic Cross Clamp - 30 - 36 cm Jaw size - 60 mm- ( 2 x 3 Teeth)
590Debakey -Chitwood Aortic Cross Clamp -Slim - 30 - 36 cm Jaw size - 120 mm- (1 x 2 Teeth)
591Debakey -Chitwood Aortic Cross Clamp -Slim30 - 36 cm Jaw size - 90 mm- ( 1 x 2 Teeth)
592Debakey -Chitwood Aortic Cross Clamp - Slim 30 - 36 cm Jaw size - 60 mm- ( 1 x 2 Teeth)
593Cosgrove type flexible shaft aortic/ vascular atrumaticClamp - Fogarty type18 inches longwith straight jaw (30-35 mm)with insert.
594SpareInserts (30-35 mm)for Cosgrove clampscompatible to the brand selected for the clamp mentioned in the item no.NC37 Mention the cost of a pair of the insert
595Cosgrove type flexible shaft aortic/ vascular atrumaticClamp - Fogarty type- 18 inches longwith straight jaw (60-65 mm)with inserts.
596SpareInserts (60-65 mm)for Cosgrove clampscompatible to the brand selected for the clamp mentioned in the item no. NC39Mention the cost of a pair of the insert
597Cosgrove type flexible shaft aortic/ vascular atrumaticClamp - Fogarty type18 inches longwith straight jaw (85-90 mm)with inserts.
598SpareInserts (85-90 mm)for Cosgrove clampscompatible to the brand selected for the clamp mentioned in the item no. NC41 Mention the cost of a pair of the insert
599Nerve or Vessel Hook - Ball tipTotal length : 32-37 cmwith working length -23 cm Tip length :10 mm
600Nerve or Vessel Hook- Fine tip Total length : 32-37 cmwith working length -23 cm Tip size :1 x 6mm
601Nerve or Vessel Hook Standard tip Total length : 32-37 cmwith working length -23 cm Jaw Size:2 x 10mm
602Nerve or Vessel Hook - 90ºwith fine tip. Total length : 32-37 cmwith working length -24-28 cm Jaw length :4-7 mm
603Jacobsonmicroscissors 25º -round handle -16 to 20 cm
604Jacobsonmicroscissors 45º -round handle -16 to 20 cm
605Jacobsonmicroscissors 60º - round handle -16 to 20 cm
606Jacobsonmicroscissors 90º - round handle -16 to 20 cm
607Jacobsonmicroscissors 125º -round handle -16 to 20 cm
608Potts / Potts Smith / Diethrich-Potts Scissors 25º -(16 to 20 cm)
609Potts / Potts Smith / Diethrich-Potts Scissors 45º -(16 to 20 cm)
610Potts / Potts Smith / Diethrich-Potts Scissors 60º -(16 to 20 cm)
611Potts / Potts Smith / Diethrich-Potts Scissors 90º -(16 to 20 cm)
612Potts / Potts Smith / Diethrich-Potts Scissors 125º- (16 to 20 cm)
613Iris scissors - ring handle with fine straight tips -10 to 12 cm
614Iris scissors - roundhandle with fine straight tips -10 to 12 cm
615DeBakeyScissors 25º - (16 to 20 cm) - Ring handle
616DeBakeyScissors 45º -(16 to 20 cm) - Ring handle
617DeBakeyScissors 60º -(16 to 20 cm) - Ring handle
618DeBakeyScissors 90º - (16 to 20 cm) - Ring handle
619DeBakeyScissors 125º -(16 to 20 cm) - Ring handle
620Favaloro vascular scissors 125º -(16 to 20 cm) - Ring handle
621Metzenbaum Scissors (Standard) 16-20 cm - curved blades - ring handle
622Metzenbaum Scissors (Long) 20-25 cm - curved blades - ring handle
623Metzenbaum Scissors (Extra-long) 30-32 cm - curved blades - ring handle
624Mayo scissors - Straight round - standard - 17-20 cm
625Mayo scissors - Curved round - standard - 19-23 cm
626Mayo-Harrington scissors - straight- 30-32 cm
627Wire Cutter - double action -Tungsten carbide edge 17-20 cm
628Rib shears (Gluck type)- 18-20 cm
629Rib shears(Bethune) - 32-36 cm
630Yankauer Suction tube- 28-35 cm
631Standard Scalpel Handle -Short 12-14 cmfor blade No.10
632Standard Scalpel Handle -Short12-14 cmfor blade No.11
633Standard Scalpel Handle -Short 12-14 cmfor blade No.15
634Standard Scalpel Handle -Short 12-14 cmfor blade No.23
635Standard Scalpel Handle -Long21-23 cmfor blade No.10
636Standard Scalpel Handle -Long21-23 cmfor blade No.11
637Standard Scalpel Handle -Long 21-23 cmfor blade No.15
638Standard Scalpel Handle -Long21-23 cmfor blade No.23
639Jacobson needle holder - Long (24-25 cm) for 2-0,3-0 & 4-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
640Jacobson needle holder - Short(18-20 cm) for 2-0,3-0 & 4-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
641Jacobson needle holder - Long (22-24 cm) for 5-0& 6-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
642Jacobson needle holder - Short(18-20 cm) for 5-0 & 6-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
643Jacobson micro-needle holder - Long (22-24 cm) for7-0 & 8-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
644Jacobson micro-needle holder - Short(18-20 cm) for7-0 & 8-0 sutures with Diamond Coatedstraight jaws & spring style round handle with ratchet & stream line box lock
645Richards Micro Needle Holder -18-20 cm for 6-0, 7-0 &8-0 sutures Diamond coated tip with straight jaws & Ring handlewith ratchet
646Ryders Needle Holder 18-20 cmfor 5-0 sutures with- Diamond coated tip with straight jaws &Ring handlewith ratchet
647DeBakey Needle Holder 24-25 cmfor 5-0 sutures with- Diamond coated tip with straight jaws &Ring handlewith ratchet
648DeBakey Needle Holder 15-16 cmfor 2-0, 3-0 & 4-0sutures with- Diamond coated tip with straight jaws & Ring handlewith ratchet
649DeBakey Needle Holder 20-22 cmfor 2-0, 3-0 & 4-0sutures with- Diamond coated tip with straight jaws & Ring handlewith ratchet
650Hegar vascular needle holderwith 1 mm wide jaw- 23-25 cm with Tungsten cardbide edgesRing handle, - with ratchet
651Hegar vascular needle holderwith 1 mm wide jaw- 20-21 cm with Tungsten cardbide edges Ring handle, - with ratchet
652Hegar vascular needle holderwith 1 mm wide jaw- 18-19 cm with Tungsten cardbide edges -Ring handle, - with ratchet
653Hegar vascular needle holderwith 1 mm wide jaw- 14-15 cm with Tungsten cardbide edges -Ring handle, - with ratchet
654TitaniumDennis Micro-forceps(straight) - 1 mm ring tip - 18-20 cm counter - balancedRound handle with Diamond coating -
655TitaniumDennis Micro-forceps(straight) -pointed platform tip -18-20 cm- counter-balancedRound handle with Diamond coating -
656TitaniumDennis Micro-forcepsstraight standard 1mm tip 18-20 cm Round handle with Diamond coating
657TitaniumGeraldMicro-forcepsstraightring tip 1mm-18-20 cm - Round handle& Diamond coating
658TitaniumGeraldMicro-forcepsstraight platform tip 1mm 18-20 cm - Flathandle& Diamond coating
659TitaniumGeraldMicro-forcepsstraight tip 1mm 18-20 cm - withflat handle
660TitaniumDeBakey Dissection -forceps -straight tip 1mm 18-20 cm -flat handle
661TitaniumDeBakey Dissection -forceps -straight tip 2 mm 18-20 cm -flat handle
662Hegar heavy needly holder - 20 cm with Tungsten Carbide edges - jaw width tapering from5 mm to 3 mm with jaw length about 20 mm
663Heavy& long needle holder -27 cm with Tungsten Carbide edges - jaw width tapering from5 mm to 3 mm with jaw length about 20 mm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail