Airports Authority Of India has published Construction Of Hangar ( Balance Work / Part ) , Associated Apron And Link Taxiway And Auxiliary Work At Dibrugarh Airport. Submission Date for this Tender is 25-08-2021. Aircraft Hanger Tenders in Dibrugarh Airport Assam. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Sub Head - Earthwork |
2 | Disposal of surplus Excavated soil beyond the initial lead including Carriage of material by mechanical transport including loading, unloading and stacking.Upto 3.0 km lead |
3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m widthas well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. a) All kinds of soil. |
4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
5 | Extra for every additionallift of 1.5m or part thereof in: a) All kinds of soil. |
6 | Excavating trenches of required width for pipes, cables, etcincluding excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m including getting outthe excavated soil, and then returning the soil as required, inlayers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :a) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
8 | Sub Head - Concrete Work RCC |
9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
10 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: a)1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
11 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
12 | SH: 3 REINFORCEDCEMENT CONCRETE |
13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)) |
14 | Centering and shuttering including strutting, propping etc. and removal of form work for a) Foundations, footings, bases of columns |
15 | Centering and shuttering including strutting, propping etc. and removal of form work for a)Columns, Pillars, Piers, Abutments, Posts and Struts |
16 | Centering and shuttering including strutting, propping etc. and removal of form work for a)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
17 | Centering and shuttering including strutting, propping etc. and removal of form work for a) Suspended floors, roofs, landing, balconies and access platform. |
18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars. a) Reinforcement for R.C.C. work (above Plinth level) |
20 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: a) 1:1.5:3 (1 cement :1.5 coarse sand (zone-III): 3 grade stone aggregate 20mm nominal size |
21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement :1.5 coarse sand (zone-III): 3 grade stone aggregate |
22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
23 | Sub Head - Brick Work |
24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
26 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level. a) Cement mortar 1:4 (1 cement :4 coarse sand). |
27 | Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry (with F.P.S bricks). |
28 | Sub Head -Wood Work |
29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) a) Second class teak wood |
30 | Providing and fixing ISI marked flush door shuttersconforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
31 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarsesand : 6 graded stone aggregate 20mm nominal size). |
32 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete a) 250 x 10 mm |
33 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete a) 100 x 10 mm |
34 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. completea) 125 mm |
35 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. completea) 100 mm |
36 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : a) Twin rubber stopper. |
37 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
38 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 250 x 16 mm |
39 | Sub Head -Steel Work |
40 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a)In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
41 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
42 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
43 | Providing and fixing ball bearing for rolling shutters. workshops & repair bays rolling shutters |
44 | Sub Head -Flooring Work |
45 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. a) 40mm thick with 20 mm nominal size stone aggregate. |
46 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
47 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. a) Size of Tile 600x600 mm |
48 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.a) Size of Tile 600x600 mm |
49 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I |
50 | Sub Head - Finishing Work |
51 | 12mm cement plaster of mixa) 1:6 (1 cement : 6 fine sand) |
52 | 15mm cement plaster on rough side of single or half brick wall of mixa) 1:6 (1 cement : 6 fine sand) |
53 | 6 mm cement plaster of mixa) 1:3 (1 cement : 3 fine sand) |
54 | Neat Cement punnig |
55 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : a) Water thinnable cement primer |
56 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
57 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
58 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade a) Two or more coats on new work |
59 | Painting with synthetic enamel paint of aapproved brand and manufacture to give an even shade: a) Two or more coats on new work |
60 | Sub Head - SANITARY INSTALLATIONS |
61 | Providing and fixingwater closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast iron P or S trap, 10 litre low level P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. a) White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests. |
62 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid,10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. a) WC pan with ISI marked white solid plastic seat and lid. |
63 | Providing and fixing white vitreous china flat back or half stall urinal of 580x380x350 mm with white PVC automatic flushing cistern with fittings, standard size CP brass flush pipe, spreaders with unions and clamps (all in CP brass) with waste fitting as perIS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fitting and brackets, cutting and making good the walls and floors wherever required: a) range of two half stall urinals with 5 litre PVC automatic flushing cistern. |
64 | Providing and fixingwash basin with C.I. / M.S. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required . White Vitreous China a)Flat back wash basin size 550x400 mm with a single 15 mm C.P. brass pillar taps. |
65 | P & F soil, waste and vent pipes: a) 100 mm dia. Sand cast iron S&S pipe as per IS : 1729 |
66 | P & F bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete a) 100mm Sand cast iron S&S as per IS : 1729 |
67 | P & F single unequal plain junction for required degree a) 100 x 100 x 75 mm Sand cast iron S&S pipe as per IS : 1729 |
68 | P & F terminal guard : a) 100 mm dia. Sand cast iron S&S pipe as per IS : 1729 |
69 | P & F trap of self cleansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors a) 100mm inlet and 100m outlet Sand cast iron S&S pipe as per IS : 1729 |
70 | Painting sand cast iron/centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. a) 100 mm diameter pipe |
71 | Painting sand cast iron/centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. a) 75 mm diameter pipe |
72 | Providing and fixing PTMT Waste coupling for wash basin and sink, of approved quality and colour Waste coupling 31 mm of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
73 | Providing and fixing PTMT Bottle Trap for wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
74 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
75 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms. |
76 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. |
77 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes. Weighing not less than 60 gms. |
78 | Providing and fixing PTMT urinal cock of approved quality and colour: a) 15 mm nominal bore, 80mm long 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms. |
79 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
80 | Sub Head -Water Supply |
81 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR .4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain and brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 ,m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Concealed work including cutting chases and making good the walls etc. |
82 | i) 20 mm nominal outer dia pipes |
83 | ii) 25 mm nominal outer dia pipes |
84 | iii) 32 mm nominal outer dia pipes |
85 | iv) 40 mm nominal outer dia pipes |
86 | v) 50 mm nominal outer dia pipes |
87 | Providing and fixing brass stop cock of approved quality a) 15 mm nominal bore |
88 | Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (screwed end) : a) 25 mm nominal bore. |
89 | Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (screwed end) : 40 mm nominal bore. |
90 | Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete: a) 25 mm nominal bore. |
91 | Providing and fixing PPR Unions |
92 | 1) PPR Union 20mm |
93 | 2) PPR Union 25mm |
94 | 3) PPR Union 32mm |
95 | 4) PPR Union 40mm |
96 | 5) PPR Union 50mm |
97 | 6) PPR Union 75mm |
98 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
99 | Sub Head -Drainage Work |
100 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement : 1 fine sand) including testing of joints etc. complete: a) 150 mm diameter. |
101 | Providing and laying cement concrete 1:5:10 (1cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round SW pipes including bed concrete as per standard design : a) 150 mm diameter SW pipe |
102 | Providing and fixing square-mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: a) 150 X 100 mm size P type. With FPS bricks class designation 75. |
103 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete a) 450 mm dia. R.C.C. pipe |
104 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 120 x 90 cm and 90 cm deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg): With FPS brick class designation 75. |
105 | Extra for depth for manholes Size 120 x 90 cm With FPS bricks class designation 75. |
106 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
107 | Sub head: Water proofing |
108 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
109 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 -160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane a) 3 mm thick |
110 | Sub Head - Aluminum Work |
111 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM/ Rubber /neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the direction of Engineer-in-charge. (Glazing and panelling to be paid for separately).a) For fixed portion:Powder coated aluminium (minimum thickness of powder coating 50 micron) |
112 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions ofEngineer-in-charge (Cost of aluminium snap beading shall be paid in basic item). |
113 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin- charge complete.355 X 19 mm |
114 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
115 | Sub head: Pavement Section |
116 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge |
117 | Preparation and consolidation of sub grade with power road roller of 8 to12 tonne capacity after excavating earth to an average of 22.5 cm. depth,dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. |
118 | Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 1)450 mm dia RCC pipes. |
119 | Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. |
120 | Cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
121 | Providing, laying, spreading and compacting graded stone aggregate(size range 53 mm to 0.075 mm ) to wet mix macadam (WMM)specification including premixing the material with water at OMC inmechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface andcompacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions ofEngineer-in-Charge |
122 | Construction of dry lean cement concrete (DRLC) sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads &lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer In-Charge. |
123 | Providing and laying in position for expansion joint, 25mm thick pre cut Synthetic joint filler board of approved make conforming to IS:1838 (part 3)-2011, 45 mm from top (to be removed at the time of filling of Polysulphide sealant), complete as per particular specifications and directions of Engineer-in-charge. (Note: Mode of measurement shall be length of joint multiplied by depth of filler board including precut portion). |
124 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.New work (Two or more coats) |
125 | Fixing of already left out M.S structural members by means of welding on already erected structure build up section, portal frame including placing of purling basing for portal with built up section / rectangular built up section by arranging necessary arrangement i.e. including scaffolding, hireing of machinery like JCB, Hydra, Crane, safety belt, halmet safety shoes for workers , maintining safety noms as per satisfaction and direction of E-I-C etc. |
126 | Finishing with one or more coats of polyurethane paint ( PU smoke grey paint) on existing M.S Structure/newly fixed structural memberin hanger building at all locations prepared and applied as per manufacturer"s specifications including PU thiner,preparation of surface, necessary scaffolding, safety belt, helmet, safety shoe etc. complete as per stisfaction and direction of Engineer-In-Charge |
127 | Fixing of single skin roofing system compressing of standing seam profile sheets on existing M.S structureto be fixed with the help of concealed compatible GI clips and wafer head zing coated self dealing fasteners/screws onthe purling. The clips shall be concealed and no fastens are to penetrate the roof sheeting. The item shall also include the cost of fixing ,flushing & trims (gable, Corner, Framed opening parapet flushing transition trims) & the work will include cost of all labour, equipment’s, materials, necessary arrangement of scaffolding,considering all safety provision of workersrequired etc during the execution of work as per satisfaction and directions of Engineer-in-charge. The agency shall ensure the water tightness of the sheeting system as whole. |
128 | Zipping of already fixed profile sheet roofing of hanger building with necessary materials, arrangementand to reach at roof top of hanger building, considering all safety provision of workers etc.all complete as per satisfaction & directions of Engineer-in-charge. Zinpping to be carried out approx. 4421 mtr. |
129 | Fixing of percolated colour profile sheets on existing structure shall be fixed over the purling/bracing with on vertical face i.e for wall with hexagonal head self drilling fasteners with neoprene EPDM washer. The work will include cost of Consumable fasteners, washers, all labour, equipment’s, materials, considering all safety provision of workers necessary arrangement of scaffolding required etc as per satisfaction and directions of Engineer-in-charge. The term shall include the cost of flashing an trims (gable corner, framed opening, parapet flashing, transition trims, expansion joints trims and ridge caps etc.) manufactured from same steel material as above (colour, finish and thickness) or manufactures recommendations all complete as per the direction of Engineer-in-Charge. The agency shall ensure the water tightness of the sheeting system as whole. |
130 | Erection & Fixing ofEave Gutters with necessary materials, arrangementand to reach at roof top of hanger building, considering all safety provision of workers etc.all complete as per satisfaction & directions of Engineer-in-charge. |
131 | Construction ofgranular Sub Base by providing close graded Material comprising of river Shingles mixed with 40 mm size crushed aggregate in the ration 65:35 ,mixing in a mechanical Mix plant at OMC, Carriage of mixed material by tippers to work site for all leads & Lifts,spreading in uniform layers of specified thickness with mortor grader on prepared surface and compacting with vibratory power roller to achieve the desired density ,complete as per specification and direction of Engineer -In -Charge. |
132 | Providing and laying PVC sheet of 200 microns on the base course with overlaps of not less than 300mm longitudinally and 300 mm transversely over and including a base layer of 6mm thick fine sand complete as per specification and as directed by Engineer-In- Charge. Providing and laying 200 Micron thick Polythene Sheet antifriction layer on the sub base course complete as per specification with specified overlap between adjacent strip and transverse joint. |
133 | Providing & laying Pavement Quality Concrete (PQC) produced in a batchingplant having a characteristic flexural strength i.e. minimum flexural strength of 4.1MPa at 28 days using 350 kg of Ordinary Portland Cement of 43 or 53 grade cementper cum of finished concrete, fine aggregate, graded stone aggregates of 40 mm nominal size in appropriate proportions as per specification and job mixed formula, laid in panels as per drawings / design as approved by the Engineer-in-Charge using fixed/slip form paver includingmaking necessary provision for expansion joints, curing etc. complete as per direction of the Engineer-In-charge and particular specifications. The item for execution shall also include the following operation. i) Mechanically cutting dummy joints 3mm wide x 1/3rd thickness of slab which is subsequently widened to 10mm for the top 25mm depth and construction joints 10mm wide x 25mm deep as per specification. ii) Filling polysulphide sealant in dummy, construction and expansion joints including providing closed-cell polyethylene foam back-up rod, and painting side of joints with polysulphide primer, etc. Complete. (To be paid separately under respective SOQ item no. 109. Note: For the purpose of tendering, the quantity of cement used for one cum. of finished concrete may be assumed as 350 kg. If the actual quantity of cement required as per laboratory mix design varies from the quantity assumed above, necessary cost adjustment for deviation in the quantity of cement as per mix design, if any shall be done as per the rate of cement in actual supply voucher from manufacturer/ authorized dealer at the time of execution.IN the case of authorized distributer, the rate may be authenticated by the manufacturer. |
134 | Providing and laying in position Polysulphide sealant of approved make conforming to BS- 5212-1990 or IS: 11433-1995. in expansion/ construction/dummy joints including rounding off edges, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per the direction of Engineer-in-Charge and technical specification. a) Expansion Joints of size 25 mm wide and 12 mm deep over 30mm dia closed-cell Polyethylene foam back-up rod, as per specifications and as per sketch. Note: For purpose of payment, quantity (Length x Width x depth) of Polysulphide sealant only will be measured). |
135 | Providing and laying in position Polysulphide sealant of approved make conforming to BS- 5212-1990 or IS: 11433-1995. in expansion/ construction/dummy joints including rounding off edges, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per the direction of Engineer-in-Charge and technical specification. a) Construction Joints size 10 mm wide and 10 mm deep over 12 mm dia closed-cell Polyethylene foam backup rod, as per specifications and as per sketch. Note: For purpose of payment, quantity (Length x Width x depth) of Polysulphide sealant only will be measured). |
136 | Providing and laying in position Polysulphide sealant of approved make conforming to BS- 5212-1990 or IS: 11433-1995. in expansion/ construction/dummy joints including rounding off edges, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per the direction of Engineer-in-Charge and technical specification. a) Dummy Joints size 10 mm wide and 10 mm deep over 12 mm dia closed-cell Polyethylene foam backup rod, as per specifications and as per sketch. Note: For purpose of payment, quantity (Length x Width x depth) of Polysulphide sealant only will be measured). |
137 | Electrical Works |
138 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR LSH PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR LSH PVC insulated copper conductor single core cable etc as required. |
139 | Group C |
140 | Wiring for twin control light point with 1.5 sq.mm FR LSH PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FR LSH PVC insulated copper conductor single core cable etc. as required. |
141 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (For Hangar Parking Area Light Control) |
142 | Group C |
143 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR LSH PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
144 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For Switch Board & Hanger light Point) |
145 | 2 x 4 sq.mm + 1 x 4 sq.mm. earth wire (For Roof Switch board ) |
146 | 4 x 2.5 sq.mm + 2 x 2.5 sq.mm. earth wire(For Switch Board & Hanger light Point) |
147 | 4 x 4 sq.mm + 2 x 4 sq.mm. earth wire ) (For Roof Switch board ) |
148 | Wiring for light/ power plug with 2X4 sq. mm FR LSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR LSH PVC insulated copper conductor single core cable for loop earthing as required. |
149 | Wiring for light/ power plug with 4X4 sq. mm FR LSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 No 4 sq. mm FR LSH PVC insulated copper conductor single core cable for loop earthing as required. |
150 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
151 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
152 | 1 or 2 Module (75mmX75mm) ( Telephone Socket outlet) |
153 | 3 Module (100mm x 75mm)(5/6 amp power plug) |
154 | 8 Module (125mm x 75mm) (15/16 amp multiple unit power plug) |
155 | Supply and fixing of following sizes of modular type switches / sockets on the existing modular plate and switch box including connection but excluding modular plate etc.of approved colour as required. |
156 | 5/6 amps switch |
157 | 5 pin 5/6 amp socket outlet |
158 | 15/16 amp switch |
159 | 6 pin 15/16 amp socket outlet |
160 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
161 | Supply and fixing ofCeiling fan regulator (step type 5 step electronic-double module) of modular typeon the existing modular plate and switch box including connection but excluding modular plate etc. of approved colour as required. |
162 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
163 | Supplying and fixing 20 amps, 240 volts, SPN industrial type,socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.( For AC unit) |
164 | Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
165 | Supplying and fixing of round shaped fan box fabricated out of 16 SWG sheet steel and 12mm M.S. bar hook duly covered with 3mm thick hylam sheet in white colour of suitable size with C.P. brass screws and having 04 nohole in outer surface for conduit entry complete as required . |
166 | Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required.(For Telephone wiring ) |
167 | 20mm |
168 | 25mm |
169 | Supply of surface mounted LED luminaire of size 2" X 2" fitting having housing made of CRCA sheet and PS diffuser lumanaire should be with minimum system efficacy of 70-80 lm/watt and minimum system lumen output > 3200 maintained life at 70 % at the end more than 40000 burning hours. The lumanaire should have CRI > 80 an CCT of 6500 K. Lumanaire shall meet IP 20 protection with THD not more than 10 % and power factor > 0.90. The total system power should not exceed >43 W including driver losses. Driver efficiency should be 85 % with surge protection more than 2 KV. Luminaire should comply with all the relavent IEC standards and should operate in a voltage range of 140 to 240 Volts AC. (Luminaire similar to Philips model no :- SM 365 C LED 33-6500 PSU-OD WH, Bajaj Cat. No.:- BCTBLS 43 W ZT WH, Surya Cat No.:-SLE DS 36 22 S ) -(For OfficeArea ) |
170 | Supply of Surface mounted LED Batten Luminaire of size 1200mm length having housing made from CRCA sheet steel & polycarbonate diffuser, mid-power LEDs of approved make CREE, NICHIA, OSRAM, LUMILEDS having lumen minimumsystem efficacy of 100lumens per watt and lumenmaintenance of 70% at the end of 50,000 burning hours, CCT of 5700K-6500K & System Lumens of > 4000 Lumens, inbuilt driver suitable for 240V/50Hz supply having voltage operating range of 140V-270Vac, PF>0.95, Surge Protection not less than 2 KV,The total system power should not exceed 40 w including driver losses THD must be <10% and overall efficiency of driver shall be >85%. LED shall have Reverse Polarity, Open & Short circuit Protection. Similar to Philips model no. BN208C LED40/CDL L1200 FR, Bajaj Cat No. BLTRU 40WH VIVA, Surya Cat No. SLE BT 55 MS (For hanger wall surface) |
171 | Supply of150W LEDIntegral vertical mountedhighbayLuminaire withaluminium reflector, control gear housing,enclosed with heat resistant toughened clear glass& accessories , complete and other standard accessories, all prewired upto terminal block suitable for 230 V+/- 10%, single phase AC supply . (Model No. BGHB 150W LED G IV, Make: Bajaj or Mode No. LHBN-150-CDL/60, Make: Crompton Greaves, or equivalent AAI approved make). |
172 | Installation, testing and commissioning of prewired, indoor LED high bay fittings of all types complete with all accessories in recess or on surface of main slab ceiling/false ceiling using suitable brass chain, including connections with 2 X 2.5 + 1 x 2.5 Sq. mm. PVC insulated FRLS copper conductor cable etc.as required. |
173 | Installation, testing and commissioning of prewired (LED light fixture 2"x2" with acrylicfront coveLightfittings) complete with all accessories and LED lamps etc. directly on ceiling/wall/ Surface including connection with 1.5 sq.mm FRLS PVC insulatedcopper conductor single corecable etc. as required. Job includes all necessary hardware required to fix the fitting on surface, ceiling,structure etc as per site requirement |
174 | Installation, testing and commissioning of LED linear /Batten lightfittings of 18 on Wall surface/cellingr site requirement,including connection with 1.5 sq.mm FRLSH PVC insulatedcopper conductor single corecable etc. as required.Job includes all necessary hardware required to fix the fitting on surface, ceiling,structure etc as per site requirement. |
175 | Supply, Installation, testing & Commissioning of 1200mm ceiling fan ISI, 5-star rated/certified with copper wound heavy duty motor in die cast aluminum housing, three nos. Aluminum blade, double ball bearings, capacitor, canopies , down rod with mounting shekel & rope hanger including wiring the down rod of standard length with 1.5 sq.mm. FRLS insulated, copper conductor, single core cable as per specifications & complete in all respects. |
176 | Supplying and fixing extra down rod of 10 cm length G.I pipe, 15 mm dia, heavy gauge including painting etc. as required.(Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
177 | Supply, Installation ,testing & commissioningof 400 mm sweep High Speed wall mounted fan i/c suitable fixing arrangent on wall and connections etc complete as required( for Hanger Parking Area) |
178 | Supply of 450 mm sweep 900 RPM heavy duty exhaust fan suitable for single phase 230 volt, 50Hz AC supply complete with motor, capacitor, louvers/shutters and all accessories as required complete. |
179 | Supply of 300 mm, sweep heavy duty exhaust fan suitable for single phase 230 volt, 50Hz AC supply complete with motor, capacitor, louvers/shutters and all accessories as required complete. |
180 | Installation of exhaust fan upto 450mm sweep in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulatedcopper conductor three corecable etc. as required. |
181 | Numbering of ceiling fan/ exhaust fan/ flurescent fitting as required. |
182 | Supply, installation, testing & commissioning of 1.5Ton, capacity, 5 star rated Split type airconditioners with min. EER of 3.5 & having copper condensing coil with 1 no. hermatically sealed compressors operating on refregerant R410A/ R-22/ R-32/ Non-CFC suitable for floor/ wall mounting conforming to IS:1391(Part-2) 1992 with upto date ammendments suitable for operation on 230V (+ 10%), 50Hz, Single phase AC supply capable for performing following functions: (i)Cooling, (ii) Dehumidifying,(iii) Air Circulation, (iv) Filtering, (v) Ventilation, including fixing of control cable, copper puipingwith insulation, drain piping upto 3 mtr. length et. complete as required as per instruction of Engineer-In-Charge (Note: AC shall contain the following part: (1) 4 Nos. suitable 5KVA voltage stablizer. (2) 4 Nos. suitable MS frame stand for outdoor unit.) |
183 | Supplying, installing, testing and commissioning of outdoor typeaviation obstraction lighting 240V roboust and reliablewith good light distribution complete etc as required.(phillips-XGP400 -IxLED-K2/RD 240V or equivalent) for hanger roof top |
184 | Supplying, installing, testing and commissioning of outdoor typeroad star wall/ ceiling mounted LED flood light of 120 W complete etc as required.(LED flood light Bajaj CAT no. BARFEG 120 W or equivalent) for hanger external electrification. |
185 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
186 | 6 way (4 + 18), Double door |
187 | 8 way (4 + 24), Double door |
188 | 12 way (4 + 36), Double door |
189 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
190 | Single pole |
191 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
192 | 25 amps |
193 | 40 amps |
194 | 63 amps |
195 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
196 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
197 | 25 amps |
198 | 40 amps |
199 | 63 amps |
200 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
201 | Supply of following sizes of Aluminium Armoured XLPE insulated &FR PVC sheathed aluminium conductor cable of 1.1KV grade as per IS 7098: 1988 Part1 with upto date amendments complete as required. |
202 | 2C x 10 Sq. mm |
203 | 4C x 4 Sq. mm |
204 | 4C x 6 Sq. mm |
205 | 3.5C x 25 Sq. mm |
206 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
207 | 2C x 10 Sq. mm |
208 | 4C x 4 Sq. mm |
209 | 4C x 6 Sq. mm |
210 | 3.5C x 25 Sq. mm |
211 | 3.5C x 35 Sq. mm |
212 | 3.5C x 300 Sq. mm |
213 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
214 | Upto 35 Sq. mm (clamped with 1mm thick saddle) |
215 | Above 185 sq.mm and upto 400 sq.mm (For 300 sqmm) |
216 | Layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required. |
217 | Above 185 sq.mm and upto 400 sq.mm (For 300 sqmm) |
218 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
219 | Above 185 sq.mm and upto 400 sq.mm (For 300 sqmm) |
220 | Layingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trunch in one tier horizontal formation including excavation and refilling the trunch etc as required but exculding sand cushionong and protective covering and refilling the trench etc. as required. |
221 | Above 185 sq.mm and upto 400 sq.mm (For 300 sqmm) |
222 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
223 | 3.5C x 300 Sq. mm |
224 | Supplying and making cable route marker with cement concrete 1:2:4 (1Cement: 2 coarse: 4 graded stone aggregate 20 mm. nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. |
225 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required. |
226 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. With charcoal / coke and salt as required. |
227 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
228 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
229 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
230 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
231 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
232 | Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface recessed steel / PVC conduit as required |
233 | 2 Pair |
234 | Supplying and drawing PVC /Polythene insulated and PVC sheathed armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped & confirming to ITD specification S/WS - 113C of approved make in existing surface or recessed conduit / casing capping |
235 | Jelly filledd armoured (PIJF) Armoured telephone cable , making necessary connection, testing etc.As required of size in existing surface or recessed conduit / casing capping(a) 20 Pair( Incoming from neary by Telecom exchange) |
236 | Supplying and fixing following modular switch/socket on the existing modular plate & Switch box including connections but excluding modular plate etc as required |
237 | Telephone socket outlet |
238 | Supply, Installation, Testing and Commissioning of cubicle type LT panel ( essential ), IP42, suitable for 415V, 3 Phase, 4 wire 50 HzAC supply systemfabricated in compartmentalized modular design from2 mm thick CRCA sheet steelfor frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with minimum 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, SMC bus bar supports,with short circuit withstand capacity of 50 KA , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections,entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main bus bar to switchgears and from switchgear output to cable termination in cable alley with required size of AL conductors / bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLSH), cable alleys, cable gland plates in two half, i/c providing following switchgears / accessories as per specifications. |
239 | INCOMER 2 Nos. 150 Amp, Thermal Maganitic release adjustable type 4 pole Moulded Case Circuit Breaker (Ics = Icu = 50 KA)With thermal magnetic release, O/L & S/C Protection with neutal link & extended bus bar teminal for connection Incomer shall have one set ofthe following items: 0 - 500 Multi functionDigital meter to measure Voltage,Current.KWH.KVA,KVAR,MD.of Each incoming andback up2 Amp MCBs - 01 Set with each Incomer 3 Nos.phase indicating LED lamps each with 2 amp back up MCB with each Incomer On & OffIndication lamp with back up Mcb with each Incomer BUSBARS TPN aluminium bus bars of minimum 200 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, side supports & their spacing etc. for withstanding fault level of 50 KA for 1 sec. BUS COUPLER 1 No.150 Amps , 4 pole Moulded Case Circuit Breaker ( Ics = Icu = 50 KA ) with built in thermal magnetic release unit with adustable setting as per specification. OUTGOING 25 Amp 4 Pole MCCB, 25KA with thermal magnetic releaser- 3 Sets 25 Amp 4 Pole MCCB, 25KA with thermal magnetic releaser- 3 Sets 63 Amp 4 Pole MCCB, 36KA with thermal magnetic release - 2 Set METERING INDICATION Suitable digital Ammeter with CT in each Outgoing Feeder. LED indication lamp for ON indication in each Outgoing Feeder. All breakers breaking capacities shall beIcu=Ics upto 433 V. Breaker/MCCB ON indication LED light with back up 2 Amp SP MCB for each Outgoings. 1 Set Rotary operating mechanism and terminal extension spreadersfor all the MCCBs. |
240 | Supply, Installation, Testing and Commissioning of cubicle type LT panel ( essential ), IP42, suitable for 415V, 3 Phase, 4 wire 50 HzAC supply systemfabricated in compartmentalized modular design from2 mm thick CRCA sheet steelfor frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with minimum 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, SMC bus bar supports,with short circuit withstand capacity of 50 KA , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections,entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main bus bar to switchgears and from switchgear output to cable termination in cable alley with required size of AL conductors / bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLSH), cable alleys, cable gland plates in two half, i/c providing following switchgears / accessories as per specifications. |
241 | INCOMER 2 Nos. 150 Amp, Thermal Maganitic release adjustable type 4 pole Moulded Case Circuit Breaker (Ics = Icu = 50 KA)With thermal magnetic release, O/L & S/C Protection with neutal link & extended bus bar teminal for connection Incomer shall have one set ofthe following items: 0 - 500 Multi functionDigital meter to measure Voltage,Current.KWH.KVA,KVAR,MD.of Each incoming andback up2 Amp MCBs - 01 Set with each Incomer 3 Nos.phase indicating LED lamps each with 2 amp back up MCB with each Incomer On & OffIndication lamp with back up Mcb with each Incomer BUSBARS TPN aluminium bus bars of minimum 200 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, side supports & their spacing etc. for withstanding fault level of 50 KA for 1 sec. BUS COUPLER 1 No.150 Amps , 4 pole Moulded Case Circuit Breaker ( Ics = Icu = 50 KA ) with built in thermal magnetic release unit with adustable setting as per specification. OUTGOING 32 Amp 4 Pole MCCB, 25KA with thermal magnetic release - 3 Set 40 Amp 4 Pole MCCB, 25KA with thermal magnetic release -2 Set METERING INDICATION Suitable digital Ammeter with CT in each Outgoing Feeder. LED indication lamp for ON indication in each Outgoing Feeder. All breakers breaking capacities shall beIcu=Ics upto 433 V. Breaker/MCCB ON indication LED light with back up 2 Amp SP MCB for each Outgoings. 1 Set Rotary operating mechanism and terminal extension spreadersfor all the MCCBs. |
242 | Supply installation testing and commissioning of UL listed microprocessor basedanalog addressable intelligent 2 loop expandable upto 5 loop Fire Alarm Panel (fire alarm capacity: Minimum 125 detectors and 125 devices in one loop and 20% spare capacity in each loop with minimum 320 character LCD display and historical logging of minimum 1000 events, flash E-Prom capable to operate on Promary AC power supply at 230Voly, 50 Hz with 24/36 Volts sealed maintenance free battery back up (as per IS) complete with automatic battery charger, etc. |
243 | Supply installation testing and commissioning of UL listed Analogue addressable Photoelectric smoke detector with twin blinking LED and base complete as per specification and as required. |
244 | Photoelectric Smoke Detector |
245 | Supply installation testing and commissioning of UL listed rate of rise cum fixed temperature addressable heat detector with visible twin blinking LED and base including connections complete as required. |
246 | Supply installation testing and commissioning of UL listed dust and vermin proof addressable anqalogue manual call boxes with flashing LED to initiate audio visual alarm in case of human detection of fire complete as required. |
247 | Supply installation testing and commissioning of UL listed wall mounted addressable sounder cum strobe with audio & visual alarm siren including connections complete as required. |
248 | Supply, installation, testing & commissioning of addessable beam detector comprising transmitter and receiver complete with mounting arrangement, power suupply unit and all accessories, interconnecting to cables etc as required and as per specifications. |
249 | Supplying, laying, testing and commissioning of wiring for smoke/heat detectors, Input/Output modules, manual call point, Hooters etc. with 2 x 1.5 sq.mm FRLS PVC insulated armoured copper conductor cable clamped on wall/ceiling including loop circuit from panel etc. complete as required. |
250 | Installation of Transformer housing Box having single/double entrywith a baseconcrete of 1:3:6 ( 1:cement, 3:coarse sand, 6:concrete of 20 mm nominal size) of size 630x630x100mm thick and all around concrete of1:2:4 ( 1: cement, 2 : coarse sand, 4 : concrete of 20mm nominal size) 150 mm and top slope as specified including providing & fixing 250 mm long 15 mm dia "B" class G.I. pipe for drainage of water etc. complete as required as per specification & drawing. |
251 | Supply of laying of 50 mm "B" class G.I. pipe including excavation of hard/ soft soil complete with threading and alignment of pipe with transformer housing box, providing check nut, bolt, etc complete as req. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy