Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh, GE (AF) SURATGARH-Rajasthan

Military Engineer Services-MES has published Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh. Submission Date for this Tender is 27-08-2021. Civil Work Tenders in GE (AF) SURATGARH Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

28763488
Corrigendum : Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh
Open Tender
Indian
Rajasthan
GE (AF) SURATGARH
27-08-2021

Tender Details

Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh Repair To Ceiling Rcc Chajja Tank Staging And Allied Engineering Works In Domestic Area In Zone B At Af Station Suratgarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: REPAIR TO CEILING RCC CHAJJA, TANK STAGING AND ALLIED ENGINEERING WORKS IN DOMESTIC AREA IN ZONE "B" AT AF STATION SURATGARH
Sl. No. Item Description
1BOQ (REPAIR TO CEILING RCC CHAJJA, TANK STAGING AND ALLIED ENGINEERING WORKS IN DOMESTIC AREA IN ZONE "B" AT AF STATION SURATGARH)
2Demolition of RCC of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition)
3M&L for providing reinforcement cement concrete 1 :2: 4 type B1 (using 20mm graded stoneagg) as inslabs supported on walls, beams and column in floors balconies,canopies, deck slabs and the shelves and the like, complete all as specified and directed.
4Formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work n.exc 200mm thick (Horizontal or sloping) flatin fair finishedsurfaces of concrete, complete all as specified and directed.
5Form work to rough finished surface of concreteedge of concrete flats, breaks in floors, opening in concrete walls,floors and roofs and side of RCC/PCC bands in walls and similar works exc 10cm but n exc 20cm thick,allas specifiedand directed.
6Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including rough finished surface of concrete on flat surface, complete as specified & directed.
7S&F mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including crankingbending and binding with mild steel (anneal) wire not less than 0.90mm dia, complete as specified & directed.
8S&F mild steel TMT bars 6 to 8mmdia , cut to length, bent to shape required, including crankingbending and binding with mild steel (anneal) wire not less than 0.90mm dia, complete as specified & directed.
9Taking down cement plaster on Brickor concrete surfaces incl racking out joints hacking for key scrubbing downwith water etc, complete all as specified & directed.
10M&L for rendering 10 mm thick in CM 1:4 on concrete surfaces on ceiling / facia /RCC Chhaja etc& finished even & smooth without using extra cement complete all as specified & directed.
11M&L for two coats of white wash on old ceiling surfaces after complete removal of existing treatment all as specified and as directed by Engr in Charge.
12S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe - 290 (Gde-E-165),complete all as specified & directed.
13S&F mild steel forframed structure liketrussed, purlins, crane gantries,postrails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, flate sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified & directed.
14M&L for preparing of RCC projection, chajja,roofs, facia etc by necessary preparation i.e scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surface of damaged, fixing of welded wiremess,binding of reinforcement bars with binding wire, removal ofloose RCC surfaces and one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced with welded mesh of weight exc 2kg per sqm but n.exc 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches, depthn exc 50mm including applying two coats of finishes to match with the existing surfaces in at any height complete all as specified. Note:- Cost of formwork , welded wiremesh and reinforcement shall be deemed to be included in unit rate quoted by the contractor.
15M&L for preparing of RCC projection, chajja,roofs, facia etc by necessary preparation i.e scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surface of damaged, fixing of welded wiremess,binding of reinforcement bars with binding wire, removal ofloose RCC surfaces and one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced with welded mesh of weight exc 2kg per sqm but n.exc 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches, depthexc 50mm but n exc 100mm including applying two coats of finishes to match with the existing surfaces in at any height complete all as specified. Note:- Cost of formwork , welded wiremesh and reinforcement shall be deemed to be included in unit rate quoted by the contractor.
16Taking up or down 15mm dia steel tubing and connections,or removal to store complete all as specified and as directed.
17Taking up or down 20mm dia steel tubing and connections, removal to store complete all as specified and as directed.
18S & F 15 mm boremedium gradegalvanised steel water tubing with all fittings concealed in wall or floor fixed to wall or laid in floors complete all as specified and directed
19S&F 20mmGI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
20Re-fixing old steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed.
21M&L for cutting chases for concealed water tubing or pinning end etc and making good the facing /cutting in cm 1 : 3 width n exc 10 cmgirth in brick walls etc complete all as specifiedand as directed.
22M&L for cutting chases for concealed water tubing or pinning end etc and making good the facing /cutting in cm 1 : 3 width exc 10 cm but not exc 20 cm girth in brick walls etc complete all as specifiedand as directed.
23M&L PCC type B0 1:2:4 (using 12.5mm graded aggregate) 25 mmavg thickness as in roof topall as specified and as directed by Engr-in-Charge
24Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by the Engr-in-Charge
25M&L for brickwork with subclass "B" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
26All as per above item No 24 here-in-before but except brickcomplete all as specified and directed.
27Dismantling existing water tankof capacity exc 250 and n exc 500 ltrs capacity and removing to store
28S&F 500 ltr capacity Rotational moulded PVC, triple layered, water storage tank (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve , complete all as specified and directed by Engineer –in-Charge.
29Dismantling existing water storage tanks exc 500 litres but n.exc 1000 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
30S&F 1000 ltr capacity Rotational moulded PVC, triple layered, water storage tank (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve , complete all as specified and directed by Engineer –in-Charge.
31Dismantling Structural steel work including doors, gatesand plate but excluding framed truss etccomplete all as specified and directed by Engr-in-Charge.
32Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coveringscomplete all as specified and directed by Engr-in-Charge.
33S & F MS steel work in tubular trussesincluding special shaped washersetc., complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 withone shop coat of zinc chromate primer paint.
34S&F for pre painted galvanlume aluminium zinc coating havingGI based corrugated steel sheets 0.50mm thick of any colour as in tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed by Engr-in-charge.
35S&F mild steel flat iron as wind tie for roof including necessary drilling for securing bolts etc complete all as specifiedand as directed.
36S&F Rolled sections Fe-290 (grade-E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
37Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
38M&L for cement concrete Type D2 1:3:6 (20 mm graded aggrete) as in foundation Filling and mass concrete, complete all as specified and directed.
39Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but not 4 Sqm each
40Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each
41Taking downshutters of any description but exc 1 sqm and not exc 2 sqm each and refixing in same opening complete all as specified and directed.
42S&Fpressed steel frames of size 105 x 60mm for doors with one or more related incl. necessary fixing lugs, hinges look strike plate etc. complete all as specified
43S&Fpressed steel frames of size 125x60mm for doors with one or more rebated incl. necessary fixing lugs, hingesstrike plate etc. complete as specified and directed.
44M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in hold fast iron fixing and back filing of pressed steel door frameincluding necessary form work all asspecified and directed.
45S&F 35 mm thick 2nd class Hard wood plain framed Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated
46S&F 35mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
47S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engr-in-Charge
48S&F mild steel butt hinges of size 100mm, medium weight, cold rolled, complete all as specified and directed.
49S&F 300mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed.
50S&F mild steel barrel tower bolt200mm, stove enamelled black with bright bolts
51S&F mild steel pressed handles 150mm, oval type, stove enamelled black
52M&L for two coats of synthetic enamel painting to wood and wood based surfaces of any description, not otherwise described over 10cm width or girth over one coat of pink primer including preparation of new surfaces.
53S&F Steel windows or ventilators, fixed type, with glazing bars, complete all as specified and directed.
54M&L for two coats of synthetic enemel painting onnew surfaces at iron and steel surfaces over a coat red oxide of any description, not otherwise described over 10cm width or girth including preparation of new steel surfaces.
55S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
56S&F, Figured glass 3 mm thick, ordinary quality and glazing with oil putty (in metal frames etc) in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed.
57S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in WALL, complete all as specified and directed.
58S & F 110 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
59M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces finishing even and smooth without using extra cement complete all as specified and as directed by the Engr-in-Charge
60Applying two coats of exterior acrylic emulsion (weather proof treatment) over a coat primer, in camouflaging patterns , including preparation of newsurfaces like brooming down or steel wire brushingscraping down smoke soot, moulds mass and efflorescent salt and trading oil and greasy spots complete all as specified and directed.
61Cleaning of Grease trap tankby taking out the sludge mud/silt etc and removing to outside of MOD premises complete all as specified and directed by Engr-in-Charge
62De-watering of septic tanks/soakage wells and sewage lineby pumping with trolley mounted pump sets including carrying the waste water in closed containers and unloading it out side the MoD land at location shown by Engr-in-Charge at a distance n. exc 5 km from the starting point including removing the existing manholes cover and replacing the same, septic tanks/soakage wells of any size/depth complete all as specified and as directed by the Engr-in-Charge Note:- (1)Hydraulically driven high pressure pump, capacity of 295L/min at 135 bar. (2)Hydraulically driven high pressure pump, having 1850 cum/hr Suction Pressure. (3)Rear hydraulic driven hose reel with 120m jetting hose. (4)proper safety of the operator during operation.
63Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No16 of tender documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail