| 1 | Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately) and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as directed by the Engr-in-Charge. |
| 2 | Taking down carefully MCB DBs SP/TPby unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 3 | Material and labour for point wiring for the One light/fan point controlled by one,one way switch with 1.5 Sqmm single core, PVC FRLS insulated unsheathed, multistranded copper conductor drawn through and includingPVC casing and caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLS insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed.Note:- Rate for making good the existing surface by using one coat primer and two coat of distemper to match the existing surface for complete wiring is deemed to be included in quoted rate. Make- KEI / Finolex / Havells for wire. |
| 4 | All as per Sr. Item No. 3 herein-above but for One 5 Pin 5 Amps socket out let point onindependentboard. |
| 5 | All as per Sr. Item No. 3 herein-above but for One 5 Pin 5 Amps socket out let point on same board alongwith other suitable switchs. |
| 6 | All as per Sr. Item No. 3 herein-above but for One light point controlled by two way switch. |
| 7 | All as per item No 3 here-in-before but using 2.5 sqmm PVC FRLS insulated copper condutor wire for connecting 15A socket on independent board. |
| 8 | Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed/directed. Make- Legrand / Havells / Schneider |
| 9 | Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, two way complete all as specifed/directed. Make- Legrand / Havells / Schneider |
| 10 | Supply and fixing of switch socket outlet combination 5 Pin, 5 Amps, 240 volts flush type (non shuttered) complete all as specified/ directed. Make- Legrand / Havells / Schneider |
| 11 | Supply & fixing of socket 5 pin 5 Amps 240 Voltsflush type (non shuttered) complete all as specified / directed. Make- Legrand / Havells / Schneider |
| 12 | Supply and fixing switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. Make- Legrand / Havells / Schneider |
| 13 | Supply and fixing ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed. Make- Legrand / Havells / Schneider |
| 14 | Supply & fixing ceiling fan regulator electronic ISI Marked, Deluxe, rotary, step type, 120/280 V. Make- Legrand / Havells / Schneider |
| 15 | Supply and fix in repairs of MCB TPN DB 4 way double door, IP 43 protection, Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed. Make- Legrand / Indo asian / Havells |
| 16 | Supply and fix in repairs of MCB SPN DB 8 way double door, IP 43 protection, Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed. Make- Legrand / Indo asian / Havells |
| 17 | Supply and fix in repairs of MCB TPN 63 Amps \"B\" Series 10 kA, 415 volts completeall as specified and directed. Make- Legrand / Indo asian / Havells |
| 18 | Supply and fix in repairs of MCB TPN 40 Amps \"B\" Series 10 kA, 415 volts, complete all as specified and directed. Make- Legrand / Indo asian / Havells |
| 19 | Supply and fix in repairs of MCB SPN 32 Amps \"B\" Series 10 kA, 240 volts completeall as specified and directed. Make- Legrand / Indo asian / Havells |
| 20 | Supply and fix in repairs of MCB SP 6 to 32 Amps \"B\" Series 10 kA,240 volts completeall as specified and directed. Make- Legrand / Indo asian / Havells |
| 21 | Supply and fixing Bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as directed. |
| 22 | Supply and fixing LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed.Make: Havell\"s Cat Part No: REGALBATTENT5UPTO1X18WDSBSWH for batten and TITANIANEO1213T8SSTL18WLED865SPC for tube light or HPL Cat part No: HPLEDT8 PC18(CW) for batten and HPLT81418PC(CW) for tube light or its equivalent in specified makes. |
| 23 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to earth lead wire 4 mm dia mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 540 mm x 540 mm x 50 mm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (light grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.. |
| 24 | Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 4 Sqmm cable one run of casing capping and one run of 4 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 25 | Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 6 Sqmm cable one run of casing capping and one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 26 | Supply and fix PVC blanking plate, one model sutable for MCB DB complete all as specified and directed Make : Legrand/Havells/ L&T |
| 27 | Supply and fixing of 9 Watt LED bulb, inverter (backup) type, A19 shape with B22 base 230 volts, battery with minimum 4 hrs backup time, frosted diffuser, suitable for surface mounting , total system lumen 900 Lm (minimum) on supply and 400 Lm (minimum) on battery, colour temperature 6500K (minimum) , CRI 80 (minimum) & taking down complete all as specified and directed. Make- Syska LED / C&S / Crompton / Phillips / Halonix |
| 28 | Taking down carefully Ceiling fan/Ehauste fan/Wall fan of any sweep & make including down rod of height n.exc 1.0 mtr long after disconnectionfrom ceiling rose and detached blades, motor from it for necessary inspection and testing, complete all as specified and directed. |
| 29 | Overhauling and opening out the ceiling fan 1200mm sweep for inspection, removing bearing, cleaning of bearing, replacement of unserviceable/worn out bearing, shaft, removing burnt out coils from the slots, cleaning and reparing of slots, rewinding of fan motor with super enamelled copper winding wire of suitable size complete including insulating materials like varnishing etc. re-assembling of fan complete all as specified and as directed. Note :Spare parts shall be measured & paid separately. |
| 30 | All as per item No 29 above but 1400mm sweep (heavy duty) (Make-Usha/Kessa/GEC or any other make) (quantity of copper winding in each stater shallnot be less than 550 gms). |
| 31 | Supply and Fixing capacitor2.5 mfd230 volts 50 Hz including taking out existing unserviceable capacitor, complete all as specified. (Make- Usha/Siemens/Unistar/bajaj). |
| 32 | Supply only ball bearing suitable for ceiling fan 1200mm to 1400mm sweep, complete all as specified. (Labour for fixing included in item 02 above). Make : SKF/ NBBC/Tata. |
| 33 | Supply and Fix down rod of ceiling fan 1200/1400mm sweep including clamps, rubber reel, lock nuts, split pin etc of standard size including taking out existing rusted down rod ,rubber reel,split pin,nuts & bolts etc, complete all as specified. |
| 34 | Material & Labour our for one coat of painting to ceiling fan complete at site with synthetic enamel paint by spraying including filling cavities with fitter materials after cleaning all dust etc including replacement of split pin, writing of MES No. on fan complete all as directed. |
| 35 | Hanging only ceiling fan and connecting up including provision PVC insulated copper cable 0.5sqmm (0.5 mtr approx) from ceiling rose to fan including provision of split Pin, nut, bolts, and washers, all as required complete. |
| 36 | M&L for rewinding of exhaust fan/pedestal fan/wall mounting fan motor any size from 225mm to 450mm with super enameled copper wire of existing size including necessary cutting & taking out of old burnt winding wire, cleaNing of slots and provision of necessary threading/sleeve work and taking out connection in lead with PVC 3core copper wire upto connector block, complete all as specified. |
| 37 | Supply only ball bearing for exhaust fan/pedestal fan/table fan upto 450mm sweep, complete all as specified. (Labour for fixing included in item 01 above). Make : SKF/ NBBC/Tata. |
| 38 | Supply and Fixing capacitor 3.5/4 mfd230 volts 50 Hz including taking out existing unserviceable capacitor complete all as specified. (Make- Usha/Siemens/Unistar/bajaj). |
| 39 | Supply only gun metal bush suitable size exhauste/pedestal fan upto 450 mm sweep suitable for fan. |
| 40 | M&L for Cleaning thoroughly exhaust fans/wall/pedestral225 to 450 mmsweep with kerosene oil and painting with spray machine with two coats of synthetic enamel white/smock gray paint after preparation of surfaces, complete. |
| 41 | Fixing only Exhaust/wall fanand connecting up including provision PVC insulated copper cable 0.5sqmm (0.5 mtr approx) from ceiling rose to fan including provision of split Pin, nut, bolts, and washers, all as required complete. |
| 42 | S&F of ceiling fan 1200 mm (minimum) sweep, BEE 5 star rated with BLDC technology, AC single phase 230 watt, including smart remote with long lasting battery to control speed, multipairing, timer and other intelligent memory functions, suspected from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling fan complete all as specified and directed. Make:- Usha Model- ENERGIA 32, HavellsModel- EFFICIENCIA NEO or equivalent in Orient / Bajaj.Note:- Old U/S ceiling fans shall be deposited to MES store. |
| 43 | Supply & fix wallfan complete withEnergy saving model 230V, 300 mm sweep. Make- Usha Model- Maxx Air Dew / Havells Model- Sameera or equivalent in Orient / Bajaj.Note:- Old U/S ceiling fans shall be deposited to MES store. |
| 44 | Supply & fix of exhaust fan 300 mm (minimum) sweep, metal body, light duty, 1200 RPM (minimum), AC single phase 230 watt, 50 Hz with bird guard, nuts, screw, bolts including electrical connection, wiring MES No in 2 cm height with synthetic enamel paint and taking down complete all as specified and directed. Make:- Usha Model- AEROCLEAN PLUS GBD DBB, Havells Model- Ventil Air-DSP or equivalent in Orient / Bajaj.Note:- Old U/S ceiling fans shall be deposited to MES store. |
| 45 | Supply & fix of exhaust fan 250 mm (minimum) sweep, non metallic plastic body, AC single phase 230 watt, 50 Hz with and including self closing louvers, nuts, screw, bolts of specified size electrical connection with twisted 3 core PVC in insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to exhaust fan and wiring MES No in 2 cm height with synthetic enamel paint and taking down complete all as specified and directed. Make- Usha Model- CRISPAIR LX EXHAUST FAN, Havells Model- Ventil Air-DX or equivalent in Orient / BajajNote:- Old U/S ceiling fans shall be deposited to MES store. |
| 46 | Supply & fix of self closing louvers of metallic body for 300 mm exhaust fan (minimum) sweep, painted with synthetic enamel paint including taking down of old unsv louvers complete all as specified and directed. |
| 47 | Schedule of Credit |