Uws Sch At Amarpur / Sh Repairing And Mtc. Of V.T Pump And Centrifugal Pump Of Raw Water And Clear Water Inc. Complete Rewinding Of Different Capacity Motor With Lowering Lifting Of Pump Motor Etc. At 0.65 Mgd Capacity Swtp, During The Yr 2021-22 Uw
Tender Overview
Project Description
Uws Sch At Amarpur / Sh Repairing And Mtc. Of V.T Pump And Centrifugal Pump Of Raw Water And Clear Water Inc. Complete Rewinding Of Different Capacity Motor With Lowering Lifting Of Pump Motor Etc. At 0.65 Mgd Capacity Swtp, During The Yr 2021-22 Uws Sch At Amarpur / Sh Repairing And Mtc. Of V.T Pump And Centrifugal Pump Of Raw Water And Clear Water Inc. Complete Rewinding Of Different Capacity Motor With Lowering Lifting Of Pump Motor Etc. At 0.65 Mgd Capacity Swtp, During The Yr 2021-22
BOQ
| Sl. No. | Item Description |
| 1 | Repairing of V.T pumps by providing and replacing of G.M bush for bowel (conforming to IS: 1710) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 2 | Repairing of V.T pumps by providing and replacing of G.M bush for sunction case/discharge case (conforming to IS: 1710) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 3 | Repairing of V.T pumps by providing and replacing of Rubber bush for bowel (conforming to IS: 1710) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 4 | Repairing of V.T pumps by providing and replacing MS lock (conforming to IS: 1710) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 5 | Repairing of V.T pumps by providing and replacing of bronze impeller (conforming to IS: 1710) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 6 | Repairing of V.T pumps by providing and replacing of SS shaft(SS-410) as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 7 | Repairing of V.T pumps by providing and replacing of CI bowel case as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 8 | Repairing of V.T pumps by providing and replacing of CI suction/discharge case as per specification and the direction of the Engineer-In-Charge. i) For 40000/50000 GPH capacity V.T pump. |
| 9 | Repairing line/ top shaft of different capacity V.T. pumps by welding, grinding, threading, centering etc as per specification and the direction of the Engineer-In-Charge. |
| 10 | Repairing of centrifugal pumps by providing and replacing of impeller(conforming to IS:1520) as per specification and the direction of the Engineer-In-Charge. A. Bronze Impelleri) For 45000/50000 GPH capacity V.T pump. |
| 11 | Repairing of centrifugal pumps by providing and replacing of Bush(sleeve)(conforming to IS: 1520) as per specification and the direction of the Engineer-In-Charge. A. SS/GM Bush(sleeve)i) For 45000/50000 GPH capacity V.T pump. |
| 12 | Repairing of centrifugal pumps by providing and replacing of joining paper(conforming to IS: 1520) as per specification and the direction of the Engineer-In-Charge. i) For 45000/50000 GPH capacity V.T pump. |
| 13 | Repairing of centrifugal pumps by providing and replacing of coupling(conforming to IS: 1520) with necessary fitting as per specification and the direction of the Engineer-In-Charge. i) For 45000/50000 GPH capacity V.T pump. |
| 14 | Repairing of centrifugal pumps by providing and replacing of Ball bearing(conforming to IS: 1520) as per specification and the direction of the Engineer-In-Charge. i) For 45000/50000 GPH capacity V.T pump. |
| 15 | Repairing of centrifugal pumps by providing and replacing of SS shaft(SS-410) as per specification and the direction of the Engineer-In-Charge. i) For 45000/50000 GPH capacity V.T pump. |
| 16 | Rewinding of Motor suitable for V.T. pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-incharge.i) 50-65 HP |
| 17 | ii) 100 HP |
| 18 | Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-incharge.i) 50 HP |
| 19 | Supplying and fitting fixing of gun metal retainer of 8\" dia size as per direction of the Engineer-in-Charge. |
| 20 | Supplying and fitting fixing of stainless steel top shaft of 9\"-11\" long 25mm dia. - 36mm dia. |
| 21 | Charges for lifting of pump, motor, column pipe etc. from intake well and stacking the same at suitable place as per specification and the direction of the Engineer-in-charge. |
| 22 | Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm as per relevant IS specification and direction of Engineer-in-charge.(i) 150 mm dia |
| 23 | Providing and fitting fixing MS foot valve as per relevant IS specification and the direction of the Engineer-in-charge.(i) 150 mm dia |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender