Urgent Execution Of Works In Different Locations Of Guwahati Medical College Hospital To Provide Facilities To Covid-19 Patients” ( Urgent Execution Of Works In Different Locations Of Neurosurgery Seminar Room, Ortho Male Ward, Diet Section, Radiology, Guwahati-Assam

Public Works Department-PWD has published Urgent Execution Of Works In Different Locations Of Guwahati Medical College Hospital To Provide Facilities To Covid-19 Patients” ( Urgent Execution Of Works In Different Locations Of Neurosurgery Seminar Room, Ortho Male Ward, Diet Section, Radiology. Submission Date for this Tender is 16-08-2021. Electrical Maintenance Tenders in Guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28724791
Urgent Execution Of Works In Different Locations Of Guwahati Medical College Hospital To Provide Facilities To Covid-19 Patients” ( Urgent Execution Of Works In Different Locations Of Neurosurgery Seminar Room, Ortho Male Ward, Diet Section, Radiology
Open Tender
Indian
Assam
Guwahati
16-08-2021

Tender Details

Urgent Execution Of Works In Different Locations Of Guwahati Medical College Hospital To Provide Facilities To Covid-19 Patients” ( Urgent Execution Of Works In Different Locations Of Neurosurgery Seminar Room, Ortho Male Ward, Diet Section, Radiology Opd To New Emergency Corridor, Psychiatric Opd Path, Psychiatric RegistrarS Room, Pediatric Surgery Ot & Seminar Room Including Repairing / Providing Collapsible Gate, Aluminum Fixed Windows, Upvc Door At Ramp, Corridor Etc. Including Electrical Works I.E. Repairing Of Electrical Installation Of Emergency Building, Replacement / Providing Fan, Ug Cable, Dbs, And Earthling System Of Sub-Stations Etc. Required In Connection With The Facilities To Provide To Covid-19Patients Atgauhati Medical College Hospital

Key Value

Document Fees
INR 6508 /-
EMD
INR 433848.0 /-
Tender Value
INR 2.16 Crore /-

BOQ Items

Name of Work:Urgent execution of works in different locations of Guwahati Medical College Hospital to provide facilities to COVID-19 patients” (Urgent execution of works in different locations of Neurosurgery seminar room, ortho male ward, diet section, radiology OPD to new emergency corridor, psychiatric OPD path, psychiatric registrar"s room, pediatric surgery OT & seminar room including repairing/ providing collapsible gate, aluminum fixed windows, uPVC door at ramp, corridor etc. including electrical works i.e. repairing of electrical installation of Emergency building, replacement / providing fan, UG cable, DBs, and Earthling system of Sub-Stations etc. required in connection with the facilities to provide to Covid-19patients atGauhati Medical College Hospital
Sl. No. Item Description
1Item no 1/1.1:-Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A. Upto a depth of 2m below the existing ground level (a) In ordinary soil
2Item no 2/1.3:-Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With silt (predominantly non plastic) by truck carriage including loading and unloading.
3Item no 3/23.18:- Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
4Item no 4/23.2:- Demolishing plain cement concrete including disposal of debris as directed for all levels (ii) Prop (1 : 3 : 6) or richer mix
5Item no 5/23.12:-Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
6Item no 6/23.2:-Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels
7Item no 7/23.3:-Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
8Item no 8/2.1.1:- Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
9Item no 9/2.2.1:- Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B)In super structure from plinth level up to 1st floor level. N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3
10Item no 10/18.1.1:- Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (ii)Super Ductile (SD) TMT reinforcement bars
11Item no 11/3.2.1:-Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
123.2.1.2:-Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
13Item no 12/4.1.8:- 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately)(A) 112mm thick brick wall (a) In cement mortar in proportion 1:4.
14Item no13/6.2.2:- 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side a) In cement mortar 1:3
15Item no 14/12.13.2:-Supplying and installing uPVC- Casement Door made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC sections of wall thickness 2.4mm, multichambered with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, locking arrangement, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. (b) Double leaf Side hung Door with a Dummy Mullion - French Door using uPVC section of size 58mm x 69mm x 2.4mm thick wall for frame,58mm x 109mm x 2.4mm thick wall for glass sash, 58mm x 61mm x 2.4mm thick wall for dummy mulion, Aluminium threshold at bottom. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) i) Using 5mm clear glass
16Item no 15/27.1:- Taking out from position and repairing steel window shutters including steel frames at all levels after cutting out the heavily rusted and damaged portion of the shutters and frames and welded with the new "Z" section of steel members, corner, hinges, stay etc. including fitting and fixing in position and riveting with new rivets adjusting, cleaning, cutting the holes and making good the damages to metal with existing one. Window grills to be removed during carrying out the work and to be re-fixed in position after completion of work. The glass panes damaged during execution should also be changed.
17Item no 16/18.4.1:- Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
18Item no17//10.2:- Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws. IIOrnamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.
19Item no 18/22.1.1:- Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
2022.1.1.1:-Extra over Item No. 22.1.1, for removing and chipping of brick bat corba, tar felt or any other existing protective layer over roof slab etc.
21Item no 19/22.1.5:- Doing patch work in existing roof slab wherever necessary by laying cement sand mortar (prop.1:4) admixed with mortar modifier cum bonding agent Nitobond SBR of Fosroc Chemicals/Rheomix 141 of BASF/Dr. Sealkit Master Bond Latex (Asian Chemicals) @ 3Ltrs per bag of cement after applying with brush a priming coat of Nitobond SBR/Rheomix 141 of BASF/Dr. Sealkit Master Bond Latex (Asian Chemicals) @ 3.5sq.m. per litre as specified & directed by the Department complete after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately).
22Item no 20/22.3.5:- Providing and laying modified bituminous water proofing membrane system in roof, Polymod-AP of choksey Chemicals, 3mm thick APP modified waterproofing membrane by torch on method using LPG torch flame after applying a coat of Bituminous primer "Primer Polymod-SB" @ 0.2kg/sq.m. complete as specified and directed by the Department followed by : Supplying, providing, mixing and laying of concrete screed of average 75mm thick in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 12mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals) @ 0.3% by weight of cement after making the concrete fibre reinforced for reducing the effect of thermal expansion by mixing concrete with Recron 3S @ 1.25kg per bag of cement and/ as specified and directed by the Department.
23Item no 21/8.1.33:- Providing Pre Painted Galvanized IronSheetRoofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
24Item no 22/8.1.34:- Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing)at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
25Item no 23/5.7.2.2:- Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
26Item no 24/5.7.1.2:- Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Executive range Somany/ Orient/Nitco/Asian Make i) Of size 200mmx300mm and above
27Item no 25/5.11.2:- Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED iii)Executive range-2 (Sizes 600 mm x600mm and above) i)Nitco madee). PVT- Hi Polish- PGVT
28Item no 26/5.10.5:- Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality (ii) With White cement
29Item no 27/16.1:- .Providing and fixing clear sheet glass beded inputty and fixed with/without wooden bidding including necessary cutting and glass to be required sized(payment for wooden bead shall be made separately) (3). Area of glass panesexceeding 0.52m2. (a). 5.00mm thick.
30Item no 28/22.3.1:- (A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat. (B) UsingRHEOMIX 131 OF BASF
31Item no 29/9.9.1:- Providing fitting and fixing 1/3panelled 2/3 glazed wooden shutters for doors/windows including oxidised iron butt hinges (100mm x75 mm x3.55 mm) with necessay screwsincluding glass panes (other fittings to be measuredand paid separately) A) With Teak wood / Sissuwood. (i) 40 mm thick.
32Item no 30/7.2.7:-Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with twoequal flanges of15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm Gypboard. False ceiling (Light Duty) with Metal Polyster Laminated Board on Back (MPL) (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screwfixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary). (i) 9.5mm MPL
33Item no 31/27.3:- Supplying, fitting and fixing 4mm thick teak plywood sheet after removing the existing damaged teak ply, over timber frame with Fevicol, nails, screws etc. including cutting sheets to proper sizes etc. complete as directed at all levels.
34Item no 32/11.4.1:- Providing, fitting and fixing anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels. (i)Partly 6mm thick glass panes and 12mm prelaminated ply board
35(iii)5mm frosted glass
36Item no 33/9.12.1:- Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (ii) 35 mm thick
37Item no 34/15.2.1:- Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts i) 300mm x 16mm
38b) Tower bolts iii) 200mm x 12mm
39c)Door handles iii) 150mm
40e)Butt hinge i) 125mm x 50mm x 4mm
41Item no 35/13.1.1:- (a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
42Item no 36/13.3.4:- Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
43Item no 37/13.2.2:- m) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. (i).Priming coat with distemper primer
44(ii) Top coat
45p) Extra over item no (m), (n) and (o) above for every subsequent coat of distempering with oil bound distemper of approved brand and manufacture.
46Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (a). With ready mixed paint , Wood primer (pink)
47Item no 39/13.6.5:- Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
48Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
49Item no 41/13.7.4:- Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
50Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (iii) Universal Closet P Trap (Cat No.C0272) (inclusive of seat cover)
51Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Counter Top Basin (A) Parryware Make (i) Duke 610 x 500 (white/coloured) (Cat. No. C8418)
52Providingfitting and fixing vitreous china flat back type lippedfront urinal basinwith standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting offittings and brackets, cutting andmaking good the walls& floors wherever required. (A) Parryware Make (a) White(i) New Magnum (Cat. No.C0575)
53Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Sona brand Bib cock
54Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Sona brand (a) 15mm dia Stop cock male-female /Angle stop cock
55Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (c )Elbow action pillar cock (Agmeco) (ii)MS-491/Heavy DutyC154+C159
56Item no 48/3.17.1:- Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Makeas specified and directed. 50mm dia
57d) 2O mm dia.
58Providing fiting & fixingC.I. Grating to the floors complete asdirected and specified. (a) 110mm dia
59Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
60Providing, fitting and fixing soap dish of Sona make complete as specified and directed. (b) Stainless Steel Soap Dish Pears/ Square Sona
61Providingfitting and fixingtowel rail of Sona make complete as directed and specified. (c ) Chrome plated towel rail 600mm long (i) Soap dish light (Cat.No.TR-0661)
62Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
63(v) 75 mm dia.
64Supplying fiting and fixing 87.5 degree PVC bendwith doorof (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
65(iv) 75 mm dia.
66Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe (A)) Exposed or in trenches b) 20 mm nominal outer dia pipe
67c) 25 mm nominal outer dia pipe
68Supplying, fiting and fixing PVC flushing cisternwith all internal fittingswith CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware makea) White (i)Economy Single Flush (Cat No.C8090/C8055)
69Providing & fixingStainless SteelRailing comparising of 50mm dia x 1.5 mm thick for hand rail and vertical post of 100 mm dia pipe @900 mm c/c and 2nos 20mm dia horizontal midrail and Vertical post to be fixed with necessary fixing accessories as per standard
70ProvidingParkingtiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 20 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. Johnson ENNdura Industrial ParkingTiles(Sizes 300 mm x 300mm x20mm)
71Providing WPC work in frame (chowk aths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 as directed and specified.(QMAX Make)
72Providing, fitting and fixing WPC factory made exterior type fully panelled single leaf door shutters (QMAX Make)
73Cost of Construction of counter for nurse station with storage fecility (Providing and Furniture constructing Erecting making of U Shaped low height storage (Under Counter slab) of width 600mm and size as per drawings,(4000X950X600) (with top, sides and bottom in 19mm thick bwr ply, back in 19mm thick commercial ply, intermediates in 19mm thickply, shutter in 19mm thick plygrade block board. All external surfaces to be finished in approved 1mm thicksun mica(high gloss) . Rate to include hardware such as approved locks, auto closing hinges for shutters, approved handles, door stop, tower bolt, etc. complete .
74Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
75Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
76With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
77With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
78Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
79With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
80With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
81Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
82Supplying including installation of socket outlet 6 Amps 3 pin universal combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
83Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
84Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
85Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
86Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)in surface/ recessedsystem complete as per direction of department. 1-2 module type Metal
873 module type Metal
886 module type Metal
898 module type Metal
9012 module type Metal
91Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)front plate of suitable colour as per direction of department. 1 module
922 module
933 module
946 module
958 module
9612 module
97Supplying including and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 1-3 module Surface Moulded PVC boxes
9812 module horizontal surface Moulded PVC boxes
99Supplying and fixing of 6A Switch flush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required.
100Supplying and fixing of 6A 5pin Socketflush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required.
101Supplying and fixing of 16A Switch flush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required.
102Supplying and fixing of 16/6A Socketflush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required
103Supplying and fixing of 16/6A Switch & Socket combined (Scombine , (I.S.I. approve(Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on existing PVC/ MS board including connection as approved by the Deptt.)complete as required
104Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
105Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 4 way TPN (4+12)double door
1066 way TPN (4+18)double door
107Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equi -valent as approved by the Deptt. make) 4 way SPN doubledoor
108Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (Schneider MG, legrand, Hagermake)" 6 to 32A
109Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (ABB, Schneider MG, legrand, Hagermake)" 40A
110Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 63A
111Supplying including fitting fixing of followingA.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model1200 mm Sweep CROMPTONmake), Premium model1050 mm Sweep CROMPTONmake)
112Supplying including fitting fixing of followingA.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalentmake) Wall 43 , 400 mm sweep
113Supplying including fitting fixing of followingA.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. b) Heavy Duty 600 mm sweep (Usha or equivelent make) (Rate as per CE"s Approved Rate)
114Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Power Flow225 mm sweep (ORIENTmake)
115Modular Motor Starter switch Relay Range 16 - 25 Amps in 3 Module
116Supplying with fitting and fixing rebuilt Rotary compressor in exchange of existing burnt out compressor complete with overhauling the Machine, Gas charging with fresh refrigerant and testing etc complete 1.50 Ton Capacity
117Supplying, fitting and fixing of Single Phase Fan Motor of 1.00 Ton to 2.00 Ton capacity Window type Air Conditioner Machine
118Gas Charging of Window type A.C. with F-22 fresh refrigerant 1.50 Ton Capacity
119"Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories)" (i) In internal wall - exposed on wall (b) 20 mm OD
120Supplying testing and commissioning of Power Contactor in the existing control panel as specified and directed by the department( D Model 3 Pole 63A, AC, Schneidermake.
121Supplying testing and commissioning of Time switches ( Analog) 24H 16A 30mts 1 channel without reserve in the existing control panel as specified and directed by the department ( Schneidermake /CRABTREE). Time switches ( Analog) 24H 16A 30mts 1 channel without reserve
122Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Core - 1, A2XY 4x400.00 Sq.mm single core unarmoured cable
123Core - 3.5, A2XY 70 Sq.mm 3 and 1/2 core unarmoured cable
124Core - 3.5, A2XY 25 Sq.mm 3 and 1/2 core unarmoured cable
125Core - 4, A2XY 10 Sq.mm four core unarmoured cable
126Supplying and drawing of weather proof aluminium conductor cable of the following size as directed and specified by the department 2.5 sq.mm twin core
1274.00 sq.mm twin core
128Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface systemincluding painting etc as required:
129Supplying and fixing 25 mm dia ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) on surface including painting etc. as required:
130Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalentmake) with 4 strips bus bar of length 350/450/600/900 mm made of aluminium alloy or wrought aluminium suitable for 100 amp capacity complete with all accessories including connectionetc. as required complete
131Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalentmake) with 4 strips bus bar of length 450/600/900/1000 mm made of aluminium alloy or wrought aluminium suitable for 200 amp capacity complete with all accessories including connectionetc. as required complete
132Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalentmake) with 4 strips bus bar of length 450/600/900/1000 mm made of aluminium alloy or wrought aluminium suitable for 300 amp capacity complete with all accessories including connectionetc. as required complete
133Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 80 mm dia. 2.00 Metres length corrosion free dual pipetechnology G.I.CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 Kand Advance Earth Pit cover (PVincluding excavation of earth pitand construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
134Supplying & laying of25x5 mmsize G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
135Supplying with fitting and fixing following 4mm thick ebonite sheets after cutting necessary cut for fitting fixing of required switch & socket on the existing GI / MS boxes with brass screw as specified and directed by the deptt. 4"X 4"
1366"X 4"
1378"X 6"
1388"X 10"
139Supplying with fitting and fixing following LED Light Fittings intrigeted driver with making necessary connection as specified and directed by the deptt. (Rate as per CE"s Approved Rate) 2ft 10W LED Tube fitting (Cromp make)
1404ft 20W LED Tube fitting (Cromp make)
1411" X 1" 18W LED Rec Indiabull make
1422" X 2" LED Recessed Indiabull make
14312-15W 8 / 6" dia round LED fittings
144Supplying including fitting fixing of following LED Driver in the existing non functioning LED fitting including necessary connection as specified and directed by the deptt. (Rate as per CE"s Approved Rate) a) 20-28 watt (Bajaj or equivelent make)
145Supplying including fitting fixing of following LED Flood Light fitting on wall or existing pole including necessary connection as specified and directed by the deptt. a) 30-50watt (Bajaj or equivelent make)
146b) 100watt (Bajaj or equivelent make)
147c) 120watt (Bajaj or equivelent make)
148d) 240watt (Bajaj or equivelent make)
149Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. a) Turbo Heavy Duty 300 mm sweep 1400 RPM Single phase (Usha or equivelent make)
150Supplying including Installation of followingA.C. Stand fan of following sweeps with making necessary connection as required complete and as directed by the Department. a) 400 mm sweepPedestal (Bajaj or equivelent make)
151Supplying including fitting fixing of followingMultifunction LCD Digital Meter at the existing power panel to record the maximum demand of load with making necessary connection as specified and directed by the Department.
152Repairing of 250KVA 11/0.443KV Copper wound oil cool existing damaged Transformer including loading unloading Carriage to the workshop and commissioning after repairing as specified and directed by the deptt.