}

Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Neonatology For 2021 22 , Consumable Items , Intravenous Line, Extension 10 Cm Double Lumen , 26G Peripheral , JIPMER PUDUCHERRY-Puducherry

Jawaharlal Institute Of Post Graduate Medical Education And Research-JIPMER has published Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Neonatology For 2021 22 , Consumable Items , Intravenous Line, Extension 10 Cm Double Lumen , 26G Peripheral . Submission Date for this Tender is 30-08-2021. Packaging Machinery Tenders in JIPMER PUDUCHERRY Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

28707389
Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Neonatology For 2021 22 , Consumable Items , Intravenous Line, Extension 10 Cm Double Lumen , 26G Peripheral
Open Tender
Indian
Puducherry
JIPMER PUDUCHERRY
30-08-2021

Tender Details

Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Neonatology For 2021 22 , Consumable Items , Intravenous Line, Extension 10 Cm Double Lumen , 26G Peripheral I.V Cannula , Neonatal Nasogastric Tubes With Number Markings Size 5F Specifications; A. Soft Material B. Maximum Length- , Neonatal Nasogastric Tubes With Number Markings Size 7F Specifications; A. Soft Material B. Maximum Length- , Neonatal Nasogastric Tubes With Number Markings Size 8F Specifications; A. Soft Material B. Maximum Length- , Peripherally Inserted Central Venous Catheter With Indroducer, 1F / 28G Specifications: A ) Peelable Cannula B ) Should Not Be More Than 30 Cm Long C ) Polyurethane / Silicone Material , Peripherally Inserted Central Venous Catheter With Indroducer 2F / 24G Specifications: A ) Peelable Cannula B ) Should Be Not More Than 30 Cm Long C ) Polyurethane / Silicone Material , Peritoneal Dialysis Catheter ( Infant ) , Peritoneal Dialysis Drainage Set , Urinemutli Reagent ( Albumin / Glucose / Ketone / Nitrite ) Strips , C Reactive Protein Bedside Latex Agglutination Diagnostic Kit , Micro Esr Tube ( Capillary Tube ) Heparinized Specifications: 1 ) Should Withstand Centrifuge Of 5000 Rpm For 5 Minutes 2 ) Inner Diameter Of Atleast 1.2 Mm 3 ) Length Of Atleast 75 Mm , Umbilical Catheter Single Lumen 3.5 F , Umbilical Catheter Single Lumen 5 F , Umbilical Catheter Double Lumen 5F , Disposable Neonatal Ventilator Circuitcompatible With Bella Vista Ventilator Specifications: 1 ) Should Have Heater Wire In Both Limbs 2 ) Should Be Single-Use Neonatal Size Tubings 3 ) Build Quality Should Be Good, Without Leaks Or Loose Connections , Breathing Circuits For Fisher & Paykel Neonatal Heatedhigh Flow Nasal Device Specifications: 1 ) Auto-Fill Humidification Chamber Compatible With F&P Mr850 Humidifier 2 ) The Circuit Tubings Should Be Kink Proof 3 ) Should Include Pressure-Relief Valve And Pressure-Monitoring Port 4 ) Tube Connecting The Nasal Cannula To The Rest Of The Circuit Should Be Flexible And Allow Free Movements Of The Neonates Head 5 ) Should Have Heater Wire , Disposable Breathing Circuits For Fisher & Paykel Neonatal Heated Humidified Cpap Device Specifications: 1 ) Should Be Single-Use Tubings Compatible With Fisher & Paykel Neonatal Heated Humidified Cpap Device 2 ) Should Include Auto-Fill Humidification Chamber Compatible With F&P Mr850 Humidifier 3 ) Should Include Heater Wire , Endotracheal Tube With Secondary Lumen ( For Surfactant Administration ) - Size 2.5 , Endotracheal Tube With Secondary Lumen ( For Surfactant Administration ) - Size 3 , Cuffed Endotracheal Tube Size 3Mm , Cuffed Endotracheal Tube Size 3.5Mm , Intercostal Drainage Tube With / Withour Trocar 8 F , Intercostal Drainage Tube With / Without Trocar 10 F , Glucometer Battery, 3V Standard Coin Shaped Lithium Battery , Cling Wrap Specifications: 1 ) Food Grade Plastic Wrap 2 ) Minimum Breadth Of 30Cm , Hydrocolloid Sterile Skin Dressing Specifications: 1 ) Water Proof Material 2 ) 15X15 Cm , Polyurethane Based Silicone Adhesive Tape Specifications: 1 ) Waterproof 2 ) Non-Allergeanc 3 ) Can Be Reapplied Without Loss Of Adhesiveness 4 ) 2X1 Inch Size Approximate. , Neonatal Ecg Skin Electrodes , Disposable Bacterial Expiratory Filter For Ventilator , Arterial Blood Gas Capillary Tubes Specifications: 1 ) Made Of Heavy-Walled Glass, With Fire Polished Ends 2 ) Sodium-Heparinized 3 ) Compatible Withsiemens Rapidlab 348 Abg Machine 4 ) Provided With End Caps And Mixing Wire5 ) Transparent6 ) Volume-100-200 Micro Litre , Phototherapy Eye Mask Specifications: 1 ) Single Piece Wrap Around Design With Velcro For Adjustment Of Tightness Of Fit 2 ) Three Sizes-Small, Medium, Large , Reusable Belt Type Neonatal Spo2 Probes Compatible With Nellcor Covidienspo2 Monitor , Disposable Belt Type Neonatal Spo2 Probes Compatible With Nellcor Covidien Spo2 Monitors , Reusable Belt Type Neonatal Spo2 Probes Compatible With Nellcor Oximax N600xspo2 Monitor , Disposable Belt Type Neonatal Spo2 Probes Compatible With Nellcor Oximax N600x Spo2 Monitors , Reusable Belt Type Neonatal Spo2 Probes Compatible With Masimo Radical 7 Spo2moniotr , Disposable Belt Type Neonatal Spo2 Probes Compatible With Masimo Radical 7 Spo2monitor , Reusable Belt Type Neonatal Spo2 Probes Compatible With Masimo Rad 97 Spo2moniotr , Disposable Belt Type Neonatal Spo2 Probes Compatible With Masimo Rad 97 Spo2monitor , Reusable Belt Type Neonatal Spo2 Probes Compatible With Masimo Spo2 Monitor Inbiult In Phoenix Open Care System Cic 101 , Resuable Neonatal T-Piece Resuscitor Tubings With Mouth Piece Compatible Withnice Neotech 5020 Hornpuff Infant Resuscitator , Resuable Neonatal T-Piece Resuscitor Tubings With Mouth Piece And Pressure Monitoring Line Compatible Withnice Neotech 5020 Hornpuff Infant Resuscitator , Single Use Flow Generator ( Interface For Connecting Nasal Cpap Mask ) To The Circuit , Invasive Bp Monitoring Linetransducer With Cable Compatible With Schiller Multipara Monitor , Non Consumables , Non Invasive Blood Pressure Cuff ( New Born ) Size 4-6 Cm Disposable Compatible With Schiller Monitors Specifications: 1 ) Should Be Reusable 2 ) Should Be Compatible With Multiparameter Monitor , Non Invasive Blood Pressure Cuff ( New Born ) Size 6-11 Cm Dispoablecompatible With Schiller Monitors Specifications: 1 ) Should Be Reusable 2 ) Should Be Compatible With Multiparameter Monitor , Non Invasive Blood Pressure Cuff ( New Born ) Size 1-4 Cm Compatible With Schiller Monitors Specifications: 1 ) Should Be Reusable 2 ) Should Be Compatible With Multiparameter Monitor , Non Invasive Blood Pressure Cuff ( New Born ) Size 4-6 Cm Resuable Compatible With Schiller Monitors Specifications: 1 ) Should Be Reusable 2 ) Should Be Compatible With Multiparameter Monitor , Non Invasive Blood Pressure Cuff ( New Born ) Size 6-11 Cm Reusable Compatible With Schiller Monitors Specifications: 1 ) Should Be Reusable 2 ) Should Be Compatible With Multiparameter Monitor , Neubauer’S Cell Counting Chamber ( For Rbc & Wbc Counting ) , Neonatal Nasal Cpap Mask, Small Size Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Prongs Allowing Free Head Movements 4 ) Soft And Plaible Material With Optimum Fit And Sealing Capability , Neonatal Nasal Cpap Mask Medium Size ( One Per Pack ) Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Prongs Allowing Free Head Movements 4 ) Soft And Pliable Material With Optimum Fit And Sealing Capability , Neonatal Nasal Cpap Mask, Large Size ( One Per Pack ) Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Prongs Allowing Free Head Movements 4 ) Soft And Pliable Material With Optimum Fit And Sealing Capability , Neonatal Nasal Cpap Prongs, Small Size Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Masks Allowing Free Head Movements 4 ) Soft And Plaible Material With Optimum Fit And Sealing Capability , Neonatal Nasal Cpap Prongs, Medium Size Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Masks Allowing Free Head Movements 4 ) Soft And Pliable Material With Optimum Fit And Sealing Capability , Neonatal Nasal Cpap Prongs, Large Size Specifications: 1 ) Compatible With Phoenix Radiant Warmer Cpap Machine 2 ) Comes Along With The Connecting Interface And Bonnet 3 ) Interface Is Made Of Flexible Tubes Which Connects Interchangeably With Masks Allowing Free Head Movements 4 ) Soft And Plaible Material With Optimum Fit And Sealing Capability , Nasal Cannula For High Flow Nasal Oxygen-Preterm Neonatal Size Specifications: 1 ) Kink-Proof And Crush-Resistant Tube 2 ) Adhesive Pads To Secure Cannulae On Cheeks 3 ) Max. Flow Rate 8 L / Min 4 ) Swivel Connection 5 ) Should Be Compatible With Breathing Circuits For Fisher & Paykel Neonatal Heated Humidified High Flow Nasal Device 6 ) Quote Should Include The Cost Of 10 Adhesive Pads For Each Cannula , Nasal Cannula For High Flow Nasal Oxygen-Term Neonatal Size Specifications: 1 ) Kink-Proof And Crush-Resistant Tube 2 ) Adhesive Pads To Secure Cannulae On Cheeks 3 ) Maximum Flow Rate 8L / Min 4 ) Swivel Connection 5 ) Should Be Compatible With Breathing Circuits For Fisher & Paykel Neonatal Heated Humidified High Flow Nasal Device 6 ) Quote Should Include The Cost Of 10 Adhesive Pads For Each Cannula , Infant Bonnet ( Size 17-22Cm ) Compatible With Fischer And Paykel Bubble Cpap Machine , Infant Bonnet ( Size 22-25 Cm ) Compatible With Fischer And Paykel Bubble Cpap Machine , Infant Bonnet ( Size 25-29 ) Compatible With Fischer And Paykel Bubble Cpap Machine , Infant Bonnet ( Size 29-36 ) Compatible With Fischer And Paykel Bubble Cpap Machine , Heater Wire Adaptor And Temperature Sensor Probe Compatible With Fischer & Paykel Mr 850 Humidifier Base And Disposable Fischer & Paykel Neonatal Ventilator Circuit Specifications 1 ) Both 2 And 3Pin Adaptor In The Inspiratory Limb , Heater Wire Adaptor And Temperature Sensor Probe Compatible With Ggm Humidifier Base And Disposable Fischer & Paykel Neonatal Ventilator Circuit , Heater Wire Adaptor And Temperature Sensor Probe Compatible With F&P Ventilator Humidifier Base And Reusable Sle Neonatal Ventilator Circuit , Heater Wire Adaptor And Temperature Sensor Probe Compatible With Bella Vista Humidifier Base And Reusable Bella Vista Neonatal Ventilator Circuit , Heater Wire Adaptor And Temperature Sensor Probe Compatible With Bella Vista Humidifier Base And Disposable Bella Vista Neonatal Ventilator Circuit , Heater Wire Adaptor And Temperature Sensor Probe Compatible With Phoenix Cpap ( Ncpap 300 ) Machine , Skin Temperature Probe Compatible With Phoenix Cic 101 Radiant Warmer , Laryngoscope Set: Fibreoptic ( Neonatal ) Specifications: 1 ) Should Be Reusable And Made Of Good Quality Metal 2 ) Each Set Should Have Miller ( Straight ) Blades Of Atleast 3 Sizes ( 00, 0, 1 ) : One Blade Of Each Size Per Set 3 ) Each Set Should Have A Handle For Neonatal Use 4 ) Fibreoptic Light Source 5 ) Including Battery , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Neonate ( 250 Ml ) Specifications: 1 ) Should Be Reusable And Autoclavable 2 ) Should Have Oxygen Reservoir 3 ) Should Have A Robust Safety Pressure Release Valve ( Pop Off Valve ) For Pressure >40 Cm H2o 4 ) Inlet Outlet And Expiratory Valves Should Be Durable Without Leaks 5 ) Equipment Should Be Able To Withstand A Fall From A Height Of 5 Feet 6 ) Should Have A Facility For Attaching A Peep Valve ( Desirable ) , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Pediatric ( 500 Ml ) Specifications: 1 ) Should Be Reusable And Autoclavable 2 ) Should Have Oxygen Reservoir 3 ) Should Have A Robust Safety Pressure Release Valve ( Pop Off Valve ) For Pressure >40 Cm H2o 4 ) Inlet Outlet And Expiratory Valves Should Be Durable Without Leaks 5 ) Equipment Should Be Able To Withstand A Fall From A Height Of 5 Feet 6 ) Should Have A Facility For Attaching A Peep Valve ( Desirable ) , Double Breast Pump Accessories Set Specifications: 1 ) Compatible With Medela Lactina Select Electric Breast Pump 2 ) Should Have One Syringe, 2 Breast Shields, 2 Connectors , 2 Tubes And 2 Bottles , Membrane Compatibel With Medela Symphony Double Breast Pump , Piston Compatible With Medela Lactina Electric Plus Breast Pump , Nasal Prongs- Infant Size Specifications: 1 ) Length Of The Connecting Tube From The Prongs Should Not Be More Than 20 Cm 2 ) The Distance Between The Two Prongs Should Be Suitable For Use In Newborns 3 ) Soft Material , Nasal Prongs- Pediatric Size Specifications: 1 ) Length Of The Connecting Tube From The Prongs Should Not Be More Than 20 Cm 2 ) The Distance Between The Two Prongs Should Be Suitable For Use In Newborns 3 ) Soft Material , Infantometer Specifications: 1. Sleek Broad Acrylic Base With One Sliding Side Adjustable As Per Length Of Baby, Dual Scale For Direct Reading In Cms / Inches Upto 90Cm. 2. Folding Sides For Easy Storage, Baby Can Comfortably Lay On The Chest Of The Scale. , Stethoscope Specifications: 1 ) Should Be Appropriate For Pediatric Use With Pediatric Size Diaphragm And Bell 2 ) Should Have Good Quality Tubing Of At Least 40 Cm Length 3 ) The Earpieces Should Be Soft And Provide A Good Seal , Digital Hand Held Luxmeter Specifications- 1 ) Portable 2 ) Measure Field With Auto-Change Scale ( 1-1999 Micro Watt / Cm2 ) 3 ) Frequency Field 400-500 Nm 4 ) Work Temperature 0-50 Degree C 5 ) Humidity 0-95% 6 ) Backed By 9 V Battery 7 ) Autonomy 300 Hours 8 ) Provision Of Signal Of Low Battery 9 ) Provision For Data Hold Button 10 ) Lcd Contrast Display 11 ) Zero Adjusting By Push Button Switch 12 ) Leather Case To Hold The Equipment , Observation Lamp Compatible With Phoenix Open Care Radiant Warmer With Cic 101 Specification: 1 ) 12 V 50 W , Observation Lampcompatible With Phoenix Open Care Radiant Warmer With Noc 100 Specification: 1 ) 12 V 50 W 2 ) Led Type , Ir Lamp Compatible With Phoenix Open Care Radiant Warmer With Cic 101 , End Bushcompatible With Phoenix Open Care Radiant Warmer With Cic 101 , Rectal Temperature Probe Compatible With Schiller Multipara Monitor , Centrifuge Specifications: 1 ) Should Be Able To Spin A Minimum Of 16 Capillary Hematocrit Tubes At The Same Time For Measurement Of Hematocrit And For Plasma Separation For Other Investigations. 2 ) Should Be Supplied With Rotor For Microhematocrit ( Capillary Tubes ) 3 ) Maximum Speed At Least 10, 000 Rpm. Increments Should Be At 1000Rpm Or Smaller. 4 ) Led Display Of Rpm 5 ) Smooth Start And Stop. 6 ) Should Be Able To Set Spin Time In The Range Of 1 To 15 Minutes Or Longer In 1-Minute Increments. A “Hold” Or “Continuous” Mode Is Preferable. 7 ) Maximum Noise Level 60Dba 8 ) Ambient Operating Temperature: 4 To 40 Degrees C 9 ) Secure, Safe Lid To Prevent Accidental Opening During Centrifugation Should Be Present.10 ) The Equipment Should Be Brought For Demonstration At Jipmer Nicu On Request. If Not, The Quotation Will Be Rejected , Cfl Lamps Compatible With 4000 Cfl Neotech Phototherapy Machine , O2 Cell Compatible With Phoenix Open Care System Cic 101 , Cpap Chamber Compatible With F&P Cpap Machine , Set Of Belts ( Teslon & Nylon Belt Compatible With Sealing Machine ) Model - Frb7701 , Sound Level Meter: Specifications- 1 ) Portable 2 ) Lcd Display 3 ) Measurement Range 30-130 Db 4 ) Resolution 0.1Db 5 ) Frequency 30-8000 Hz 6 ) Should Have Range Selector E.G. 30-80Db, 50-100Db, 0-130Db 7 ) Electric Condenser Microphone Type 8 ) Should Work Both On Power And Rechargable Battery 9 ) Low Battery Indicator 10 ) Should Provide Power Adapter For Charging 11 ) Leather Cse To Hold The Equipment , Cold Light Specifications: 1.Should Consist Of A Light Source And A Flexible Fibreoptic Cable. 3.Should Output High Intensity White Light Adequate To Visualize Upper Limb Arteries In Term Neonates When Transilluminated At The Wrist. 4.Fibreoptic Cable Should Be Longer Than 60 Cm. 6.The System Should Be Compact And Light-Weight And Portable. 7.Should Not Heat Patient Skin Or Tissues Or Cause Burns When Used For 5 Minutes For Transillumination. 8.Should Come With Ac Current Adapter For 220-240V. , Non Stretchable Head Circumference Measuring Tape , Thermal Reflector For Temperature Probe ( Neonatal Size ) , Ultrasonic Nebulizer Machine Specifications: 1.Should Be Light Weight, Portable, Compact And Easy To Use. 2 Frequency Of Ultrasonic Generator Should Be Greater Than 1.5 Mhz 3 Should Have 3 Speed Nebulization Rate Control ( Minimum, Medium, Maximum ) 7 Should Uses Water As Ultrasonic Conduction Medium 8 Should Provide Silent Operation. 9 Should Have A Built In Timer And Shuts Off After 10 Minutes Use 10.Should Be Provided With A Complete Nebulisation Kit And Medication Cup – 5 Nos

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail