Military Engineer Services-MES has published Repair / Rewinding Of Ceiling Fans, Exhaust Fans, Geysers And Repair / Replacement Of Internal Wiring, Electrical Fittings And Connected Items At Lower And Upper Leimakhong Mil Stn And Koirenge Repair / Rewinding Of Ceiling Fans, Exhaust Fans,. Submission Date for this Tender is 20-08-2021. Electrical Maintenance Tenders in LEIMAKHONG Manipur. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | E/M WORKS |
2 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc completeall as specified and directed. |
3 | Material and labour for point wiring surface type with two single core 2.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 2.5 Sq mm for one 5 pin 15 amp socket outletand connecting to light fitting/fans/call bell etc completeall as specified and directed for following :- (Colour code to be followed) |
4 | Material and labour in for sub mainwiringtwo single core 4.0 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 4.0 Sq mm and connecting to light fitting/fans etc including taking down old unserviceable sub main wiring. completeall as specified and directed for following :- (Colour code to be followed) |
5 | Material and labour in for sub mainwiringtwo single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc including taking down old unserviceable sub main wiring. completeall as specified and directed for following :- (Colour code to be followed) |
6 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed) |
7 | One light/fan point controlled by one, one way switch |
8 | One bell point controlled by one, one way switch |
9 | One socket outlet 5 Amps 5 pin on independent board |
10 | One socket outlet 5 Amps 5 pin on same board with other switches |
11 | S&Fmodular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
12 | S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
13 | S&F modular socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed. |
14 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
15 | S&Fmodular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
16 | S&F modular Bell push 6A, 1 module complete all as specified and directed. |
17 | S&F in repair buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. |
18 | S&F in repairs modular white cover with frame for 01module complete all as specified and directed. |
19 | S&F in repairs modular white cover with frame for 02module complete all as specified and directed. |
20 | S&Fin repairs modular white cover with frame for 03module complete all as specified and directed. |
21 | S&Fin repairs modular white cover with frame for 04module complete all as specified and directed. |
22 | S&Fin repairs modular white cover with frame for 06module complete all as specified and directed. |
23 | S&Fin repairs modular white cover with frame for 08module complete all as specified and directed. |
24 | S&Fin repairs modular white cover with frame for 12module complete all as specified and directed. |
25 | S&F blank spacer plate for single module complete all as specified and directed. |
26 | S&F modular electronic fan regulator rotary stepped type 120W, 240V, single phase, two module and connecting up complete all as specified and directed. |
27 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. |
28 | Taking downold unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. |
29 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 04 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. (Make: Havells cat part No. DHDPSHODRW 04 or as per list of approved makes enclosed hereinafter) |
30 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 08 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. (Make: Havells cat part No. DHDPSHODRW 08 or as per list of approved makes enclosed hereinafter) |
31 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. (Make: Havells cat part No. DHDPSHODRW 12 or as per list of approved makes enclosed hereinafter) |
32 | S&F MCB single pole and neutral 40 to 63Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
33 | S&F MCB single pole and neutral 32Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
34 | S&F MCB single pole 06 to 32Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
35 | S&F in replacement PVC Board (30 x 25 x 5) cm depth medium quality ISI marked complete all as directed. |
36 | Taking down old unserviceable service wire including batten/suspending wires complete all as directed. |
37 | M & L for sub main wiring with 2 single core 2.50 Sqmm PVC FRLS insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing/capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 2.50 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire including taking down old unserviceable sub main wiring. complete all as specified and directed. (Note: Two run of single core cable and one run earth wire will be measured as one length) |
38 | S&FService wire PVC insulated and PVC sheathed stranded Aluminium conductor 10 sq mm 2 Core fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulator completeall as directed. |
39 | S&FService wire PVC insulated and PVC sheathed stranded Aluminium conductor 6 sq mm 2 Core fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulator completeall as directed. |
40 | S&F in repair plug top 16A, 240volts.complete all as directed. |
41 | S&F in repair plug top 6A, 240volts.complete all as directed. |
42 | Taking down carefully ceiling/exhaust fan of any sweep and any make, disconnecting from ceiling rose and carrying out necessary repairsincluding overhauling, cleaning internally & externally, oiling, greasing, checking of eletrical connections, reassembling, testing and hanging/fixing in its original position complete all as directed.(Note :Rewinding / Cost of components shall be measured and paid separately under respective items here-in-after). |
43 | M&L for rewinding of ceiling / exhaust fan with super enameled copper winding wire of suitable size and providing with suitable insulation to fan including replacement of worn out nut, bolt, washers, split pin etc. complete all as directed for the following type of fans:- |
44 | Ceiling fan of any Make 1200 mm to 1400 mm sweep |
45 | Exhaust fan of any Make 300mm to 380mm sweep. |
46 | Exhaust fan of any Make 450 mmsweep. |
47 | Supply only thefollowing components of fan in replacement of unserviceable all as directed:- |
48 | Ball bearing of suitable size for ceiling fan/Exhaust fan of any size and sweep. |
49 | Condenser 2.5/3.15 Mfd for ceiling fan/exhaust fan of any size and sweep. |
50 | Condenser 4 Mfd capacity 230 volts AC suitable for ceiling fan/exhaust fan |
51 | MS Clamps with nut bolts and washers for hanging of ceiling fan of any size. |
52 | Removing storage type water geysers of 50/25 ltrs capacity of any type, make & model from its existing location, transportation to work shop forrepairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following a) Dismantling complete geyser and carrying out complete overhauling i.e; disconnecting electric supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete.Notes:- Spare parts, safety devices with its required accessories shall be measured and paid seperately at supply only rates here-in-after . |
53 | Supply only the following parts for geysers 50/25 Ltrs capacity. (Make of parts shall be as per make of Geysers) : |
54 | Heating element 2 KW suitable for operation on 230V AC 50Hz |
55 | Heating element 1.5KW suitable for operation on 230V AC 50Hz |
56 | Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser. |
57 | Pressure release valve dead weight type for 25/ 50 Ltrs capacity Geyser. |
58 | Supply and fix steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for 15 mm dia bore. Completed all as specify & directed. |
59 | S&F in repairs bib taps cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe of 15 mm dia or brass ferrule and fixed. Completed all as specify & directed. |
60 | S&F in repairs stop valves 15mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed botyh ends for iron pipe or for unions and fixed. Completed all as specify & directed. |
61 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm long.Completed all as specify & directed. |
62 | S&F in repairs PVC casing caping of size 20x12mm, heavy grade including all fitting accessories complete all as specified and directed. |
63 | S&F in repairs PVC casing caping of size 25x15mm, heavy grade including all fitting accessories complete all as specified and directed. |
64 | S&F in repairs 20mm dia PVC conduit pipe, mediumgrade including all fitting/conduit accessories complete all as specified and directed. |
65 | S&F building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP-66 high power LED light 25 watt including suitable size of wall bracket and connecting complete all as specified and directed. (Make: Havells Endura Pearl Cat No. LHEWEBP7PL6S025 or equivalent model in Bajaj/Philips/CG) |
66 | S & F in replacement of 8 watt Green permorm sleek is a high performance low -height LED downlighter suited for requirements of any modern professional workspace in cool white/warm white/natural white.Robust PDC housing ensures long system.Narrow rim renders a pleasing aesthetic look including taking down old fitting as specified and directed.(Make: Philips: DN295B LED8S-6500 PSU WH or equivalent to Havells/Bajaj/CG |
67 | S & Fessential smart bright track light 8 watt is a high performance hassle free solution for upto 5 years of use in cool white/warm white/natural white, range has high efficacy of up to 100lm/w and aluminium housing for better thermal management.Available in black &white color housing and all as specified and directed.(Make: Philips: Cat no-STO3OT LED8/830 8W 220-240V I MB WH or equivalent to Havells/Bajaj/CG) |
68 | S & F in replacement of lumeno LED Downlighter round 5W aesthetically designed ,decorative recess mounted spot light low ceiling height applications all as specified and directed.(Make: Havells LED Light lumeno 5W Round 6500K, Cat no-LHEEBPP7IN1W005 or equivalent to Philips/Bajaj/CG) |
69 | S & F in replacement recess mounting luminaire ultra modern ,environment friendly,new genneration ,aesthetically designed with high brightness SMD LEDS as light source suitable for armstrong/grid ceiling,2x2 ft,34W,4000K,240V in cool white/warm white/natural white and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.(Make: Philips: Cat no-RC380B LED30S-6500 G5 L60W60 PSU OD SG or equivalent to Havells/Bajaj/CG) |
70 | M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type including one 10W LED complete all as specified and directed. (Make : Holder - ISI product of ANCHOR/ Legrand/ Havells, Lamp - Bajaj/ Philips/ Havells) |
71 | S & F in repaire LED bulb 15 watt in cool white/warm white/natural white. |
72 | S & F in repaire LED bulb 9 watt in cool white/warm white/natural white. |
73 | S & F in repaire LED bulb 5 watt in cool white/warm white/natural white. |
74 | S & F in repaire LED bulb 3 watt in cool white/warm white/natural white. |
75 | S & F in repaire LED bulb zerowatt in cool white/warm white/natural white. |
76 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: GI Earthing lead upto 7.5m in length is deemed to be included in the unit rate. The lead required beyond 7.5m shall be measured and paid for separately) |