National Security Guard-NSG has published Annual Repair Maintenance Of Cpf Buildings At Nsg Manesar For The Year 2021 22 Civil And Electrical Arm Of Cpf Buildings At Nsg Manesar For The Year 2021 22 Civil And Electrical. Submission Date for this Tender is 09-08-2021. Electrical Maintenance Tenders in NSG Manesar Garrison Gurugram Haryana Haryana. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
2 | All kinds of soil |
3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
4 | Excavating, suipplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
6 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
7 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mmnominalsize derivedfromnatural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling&dressing & finishing the top smooth. |
8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
9 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
10 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters,buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement |
11 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources). |
12 | Centering and shuttering including strutting, propping etc. and removal of form for |
13 | Suspended floors, roofs, landings, balconies and access platform |
14 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
15 | Columns, Pillars, Piers, Abutments, Posts and Struts |
16 | Centering and shuttering including strutting, propping etc. and removal of form for |
17 | Edges of slabs and breaks in floors and walls |
18 | Under 20 cm wide |
19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
20 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
22 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
24 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
26 | cement mortar 1:4 (1 cement : 4 coarse sand) |
27 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
28 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
29 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
30 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
31 | 300x16 mm |
32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
33 | 300x10 mm |
34 | 250x10 mm |
35 | 100x10 mm |
36 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
37 | 125 mm |
38 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. Thew frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
39 | Providing and fixing to existing door frames |
40 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in differenct plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS:14856, complete as per direction of Engineer-in-charge |
41 | Steel work in built up tabular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
42 | Hot finished welded type tubes |
43 | Steel work wleded in built up sections/frames work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
44 | In granting, frames, guard bar, ladder, railings, brackets, gates and similar works |
45 | Provinding & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
46 | 4.0 mm thick glass panes |
47 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
48 | 40 mm thick with 20 mm nominal size stone aggregate |
49 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
50 | Providng and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type B (WORKING PRESSURE 6 KG/SQCM), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
51 | 110 mm diameter |
52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type B (WORKING PRESSURE 6 KG/SQCM), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
53 | Single tee without door |
54 | 110x110x110 mm |
55 | Bend 87.5o |
56 | 110 mm bend |
57 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 507 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns, Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desirted by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
58 | 12 mm cement plaster of mix : |
59 | 1:6 (1 cement: 6 coarse sand) |
60 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
61 | 1:6 (1 cement: 6 coarse sand) |
62 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. |
63 | Two or more coats on new work |
64 | Finishing walls with water proofing cement paint of required shade : |
65 | New York (Two or more coats applied @ 3.84 kg/10 sqm) |
66 | Applying priming coat |
67 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
68 | Painting and synthetic enamel paint of approved brand and manufacture to give an even shade: |
69 | Two or more coats on new work |
70 | Providing and appling of white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
71 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
72 | 20 mm dia nominal bore |
73 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work |
74 | 25 mm nominal bore metre 364.55 |
75 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : : |
76 | 20 mm nominal bore |
77 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separeately. |
78 | Providing and fixing of CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
79 | 15 mm nominal bore |
80 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
81 | 15mm nominal bore |
82 | Providing and fixing PTMT, push cock of approved quality and colour. |
83 | 15 mm nominal bore, 98mm long, weighing not less than 75 gms |
84 | Providing and fixing PTMT grating of approval quality and colour. |
85 | 125 mm nominal dia with 25 mm waste hole |
86 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
87 | 15 mm nominal bore with 45 cm length |
88 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm, with fittings, clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
89 | Range of four half stall urinals |
90 | Elect Work |
91 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
92 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
93 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
94 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
95 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
96 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
97 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
98 | 8 way , Double door |
99 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
100 | Single pole |
101 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
102 | 40 A |
103 | Supply, Installation, testing and commissioning of 20/21W aluminium extruded LED fitting 4" long , complete with all accessories Model no. BN021C LED20S make Philips or equivalent make of C&S/ Havells directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
104 | Supply, Installation, testing and commissioning of 36W CRCA LED panel 2"X2" , complete with all accessories Model no. LTCSP36WLED2x2 Make- C&S or equivalent directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
105 | Supply, installation testing and commissinoning of 120W LED model no LTEF120WHPLED make C&S or equivalent flood light fitting with on existing pole including connection etc as reqd. including connection etc. as required. |